ČIA 2254 • Plzeň, Czech Republic • 47 calibration items

Metrology & calibration

ENERGIZE GROUP s.r.o. is a calibration laboratory accredited by ČIA under number 2254 (Plzeň, Czech Republic). Its accreditation scope covers 47 calibration items in the following areas: Metrology & calibration. Calibrated items include: Gauge pressure and absolute pressure / deformation and digital mano…, Analogue and digital thermometer, AC current / AC current meters and sources, Electrical resistance / DC resistance meters and generators. Most frequently used calibration principles: Comparison or direct measurement with a standard multimeter, Comparison with a standard resistance sensor in a calibrating oven, Comparison with a standard resistance sensor in an oil bath.

At a glance

  • Accreditation number: ČIA 2254
  • Calibration items in scope: 47
  • Types of calibrated items: 26
  • Calibration principles used: 28
  • City: Plzeň, Czech Republic
  • Valid until: 21-08-2030
Accreditation number
2254
Accreditation body
ČIA
Address
Jižní Předměstí 2923, 301 00 Plzeň
City
Plzeň, Czech Republic
Division
OŚRODEK SŁUŻBY WZORCOWANIA
Valid until
21-08-2030

What this laboratory calibrates (26)

Calibration principles (28)

Certificate information

Certificate date
17.03.2026

Accreditation scope — calibration items (47)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress
medium air — -95 kPa to -2,5 kPa · CMC 60 Pa
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a digital manometer 92/75-15-1
2 Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress
medium air — -2,5 kPa to 2,5 kPa · CMC 2 Pa
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a micromanometer 92/75-15-2
3 Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress
medium nitrogen — 2,5 kPa to 20 kPa · CMC 4 Pa medium nitrogen — 20 kPa to 200 kPa · CMC 2.10⁻⁴ medium nitrogen — 0,2 MPa to 1 MPa · CMC 250 Pa medium nitrogen — 1 MPa to 10 MPa · CMC 25.10⁻⁵
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a ball manometer 92/75-15-3
4 Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress
medium oil — 0,025 MPa to 0,6 MPa · CMC 300 Pa
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a piston manometer 92/75-15-1, 92/75-15-2
5 Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress
medium oil — 0,6 MPa to 60 MPa · CMC 5.10⁻⁴
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a piston manometer 92/75-15-3
6 Absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress
medium air — 0 kPa to 100 kPa · CMC 26 Pa medium air — 100 kPa to 200 kPa · CMC 1.10⁻⁴ + 23 Pa
CMC for the field of measured quantity: Pressure, mechanical stress
Comparison with a digital manometer 92/75-15-1, 92/75-15-2, 92/75-15-3
7 Thermocouple S Calibration – temperature
100 °C to 500 °C · CMC 0,70 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in a calibrating oven 92/75-14-1
8 Thermocouple S Calibration – temperature
400 °C to 1100 °C · CMC 1,6 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric sensor in a horizontal furnace 92/75-14-1
9 Thermocouple - base metals Calibration – temperature
0 °C to 30 °C · CMC 0,40 °C 200 °C to 500 °C · CMC 0,63 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in a calibrating oven 92/75-14-1
10 Thermocouple - base metals Calibration – temperature
30 °C to 200 °C · CMC 0,43 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in an oil bath 92/75-14-1
11 Thermocouple - base metals Calibration – temperature
500 °C to 1100 °C · CMC 1,6 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric sensor in a horizontal furnace 92/75-14-1
12 Resistance thermometer Calibration – temperature
-30 °C to 30 °C · CMC 0,27 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in a climatic chamber 92/75-14-2
13 Resistance thermometer Calibration – temperature
30 °C to 200 °C · CMC 0,16 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in an oil bath 92/75-14-2
14 Resistance thermometer Calibration – temperature
200 °C to 500 °C · CMC 0,53 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in a calibrating oven 92/75-14-2
15 Glass thermometer Calibration – temperature
0 °C · CMC 0,11 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in a Dewar flask 92/75-14-3
16 Glass thermometer Calibration – temperature
30 °C to 200 °C · CMC 0,15 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in an oil bath 92/75-14-3
17 Analogue and digital thermometer Calibration – temperature
-30 °C to 30 °C · CMC 0,27 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in a climatic chamber 92/75-14-4
18 Analogue and digital thermometer Calibration – temperature
30 °C to 200 °C · CMC 0,16 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in an oil bath 92/75-14-4
19 Analogue and digital thermometer Calibration – temperature
200 °C to 500 °C · CMC 0,53 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance sensor in a calibrating oven 92/75-14-4
20 Analogue and digital thermometer Calibration – temperature
500 °C to 1100 °C · CMC 1,6 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric sensor in a horizontal furnace 92/75-14-4
21 Direct indicating thermometers and measuring chains Calibration – temperature
-30 °C to 200 °C · CMC 0,30 °C 200 °C to 500 °C · CMC 0,60 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard resistance thermometer in a calibrating oven 92/75-14-5
22 Direct indicating thermometers and measuring chains Calibration – temperature
500 °C to 1100 °C · CMC 1,7 °C
CMC for the field of measured quantity: Temperature
Comparison with a standard thermoelectric sensor 92/75-14-5
23 Temperature meters and calibrators Calibration – temperature
type R thermocouples — -50 °C to 1760 °C · CMC 2,1 °C type S thermocouples — -50 °C to 1760 °C · CMC 2,1 °C type B thermocouples — 0 °C to 1820 °C · CMC 1,8 °C type J thermocouples — -210 °C to 1200 °C · CMC 0,7 °C type T thermocouples — -270 °C to 400 °C · CMC 0,5 °C type E thermocouples — -270 °C to 1000 °C · CMC 0,5 °C type K thermocouples — -270 °C to 1370 °C · CMC 0,8 °C type N thermocouples — -270 °C to 1300 °C · CMC 0,8 °C
CMC for the field of measured quantity: Temperature
Simulation and measurement of DC voltage of thermoelectric temperature sensors 92/75-17-7
24 Temperature meters and calibrators Calibration – temperature
Pt100 resistance sensors — -200 °C to 850 °C · CMC 0,4 °C Pt200 resistance sensors — -200 °C to 850 °C · CMC 0,3 °C Pt1000 resistance sensors — -200 °C to 850 °C · CMC 0,5 °C Ni100 resistance sensors — -60 °C to 250 °C · CMC 0,2 °C
CMC for the field of measured quantity: Temperature
Simulation and measurement of resistance of resistance temperature sensors 92/75-17-7
25 Analogue and digital hygrometers, humidity transducers and humidity measuring chains, including humidity probes Calibration – air humidity
18 °C to 28 °C — 10 % RH to 90 % RH · CMC 1,4 % RH
CMC for the field of measured quantity: Air humidity
Comparison with a reference capacitive hygrometer in an air-conditioning chamber 92/75-14-6
26 DC voltage / DC voltage meters and sources Calibration – electrical quantities
0 mV to 10 mV · CMC 0,0050 % + 0,3 µV 10 mV to 200 mV · CMC 0,0017 % 200 mV to 2 V · CMC 0,0010 % 2 V to 20 V · CMC 0,0009 % 20 V to 1000 V · CMC 0,0014 %
CMC for the field of measured quantity: Electrical quantities
Comparison or direct measurement with a standard multimeter 92/75-17-1, 92/75-17-6, 92/75-17-9
27 DC voltage / inspection equipment Calibration – electrical quantities
1 kV to 5 kV · CMC 0,48 %
CMC for the field of measured quantity: Electrical quantities
Measurement by a calibrator of inspection instruments 92/75-17-1, 92/75-17-6, 92/75-17-9
28 DC current / DC current meters and sources Calibration – electrical quantities
1 µA to 10 µA · CMC 0,015 % 10 µA to 200 µA · CMC 0,012 % 200 µA to 20 mA · CMC 0,0082 %
CMC for the field of measured quantity: Electrical quantities
Comparison or direct measurement with a standard multimeter 92/75-17-1, 92/75-17-6, 92/75-17-9
29 DC current / DC current meters and sources Calibration – electrical quantities
20 mA to 10 A · CMC 0,0062 % 10 A to 100 A · CMC 0,013 % 100 A to 1000 A · CMC 2,4 %
CMC for the field of measured quantity: Electrical quantities
Comparison or measurement with a standard multimeter with a current shunt 92/75-17-1, 92/75-17-6, 92/75-17-9
30 DC current / clamp testers Calibration – electrical quantities
1 mA to 1000 A · CMC 0,35 %
CMC for the field of measured quantity: Electrical quantities
Measurement of current simulated by a standard calibrator with current coil 92/75-17-1, 92/75-17-6, 92/75-17-9
31 AC voltage / AC voltage meters and sources Calibration – electrical quantities
40 Hz to 100 Hz — 10 mV to 200 mV · CMC 0,020 % + 15 µV 100 Hz to 2 kHz — 10 mV to 200 mV · CMC 0,015 % + 14 µV 2 kHz to 10 kHz — 10 mV to 200 mV · CMC 0,022 % + 15 µV 10 kHz to 30 kHz — 10 mV to 200 mV · CMC 0,040 % + 15 µV 30 kHz to 100 kHz — 10 mV to 200 mV · CMC 0,089 % + 15 µV 40 Hz to 100 Hz — 200 mV to 2 V · CMC 0,013 % + 32 µV 100 Hz to 2 kHz — 200 mV to 2 V · CMC 0,012 % + 32 µV 2 kHz to 10 kHz — 200 mV to 2 V · CMC 0,013 % + 32 µV 10 kHz to 30 kHz — 200 mV to 2 V · CMC 0,025 % + 52 µV 30 kHz to 100 kHz — 200 mV to 2 V · CMC 0,059 % + 0,24 mV 40 Hz to 100 Hz — 2 V to 20 V · CMC 0,013 % + 0,32 mV 100 Hz to 2 kHz — 2 V to 20 V · CMC 0,012 % + 0,32 mV 2 kHz to 10 kHz — 2 V to 20 V · CMC 0,013 % + 0,32 mV 10 kHz to 30 kHz — 2 V to 20 V · CMC 0,025 % + 0,52 mV 30 kHz to 100 kHz — 2 V to 20 V · CMC 0,059 % + 2,4 mV 40 Hz to 100 Hz — 20 V to 200 V · CMC 0,014 % + 3,2 mV 100 Hz to 2 kHz — 20 V to 200 V · CMC 0,012 % + 3,2 mV 2 kHz to 10 kHz — 20 V to 200 V · CMC 0,014 % + 3,2 mV 10 kHz to 30 kHz — 20 V to 200 V · CMC 0,026 % + 5,2 mV 30 kHz to 100 kHz — 20 V to 200 V · CMC 0,059 % + 24 mV 40 Hz to 10 kHz — 200 V to 1000 V · CMC 0,015 % + 26 mV 10 kHz to 30 kHz — 200 V to 1000 V · CMC 0,031 % + 58 mV
CMC for the field of measured quantity: Electrical quantities
Comparison or direct measurement with a standard multimeter 92/75-17-1, 92/75-17-6, 92/75-17-9
32 AC voltage / inspection equipment Calibration – electrical quantities
50 Hz, 60 kHz — 1 kV to 5 kV · CMC 0,48 %
CMC for the field of measured quantity: Electrical quantities
Measurement by a calibrator of inspection instruments 92/75-17-1, 92/75-17-6, 92/75-17-9
33 AC current / AC current meters and sources Calibration – electrical quantities
40 Hz to 1 kHz — 10 µA to 200 µA · CMC 0,035 % + 0,024 µA 1 kHz to 5 kHz — 10 µA to 200 µA · CMC 0,048 % + 0,024 µA 40 Hz to 1 kHz — 200 µA to 2 mA · CMC 0,033 % + 0,24 µA 1 kHz to 5 kHz — 200 µA to 2 mA · CMC 0,038 % + 0,24 µA 40 Hz to 1 kHz — 2 mA to 20 mA · CMC 0,033 % + 2,4 µA 1 kHz to 5 kHz — 2 mA to 20 mA · CMC 0,038 % + 2,4 µA 40 Hz to 1 kHz — 20 mA to 200 mA · CMC 0,032 % + 24 µA 1 kHz to 5 kHz — 20 mA to 200 mA · CMC 0,037 % + 24 µA 40 Hz to 1 kHz — 200 mA to 2 A · CMC 0,075 % + 0,24 mA 1 kHz to 5 kHz — 200 mA to 2 A · CMC 0,086 % + 0,24 mA
CMC for the field of measured quantity: Electrical quantities
Comparison or direct measurement with a standard multimeter 92/75-17-1, 92/75-17-6, 92/75-17-9
34 AC current / AC current meters and sources Calibration – electrical quantities
50 Hz, 60 Hz — 2 A to 10 A · CMC 0,035 % + 0,16 mA
CMC for the field of measured quantity: Electrical quantities
Comparison or measurement with a standard multimeter with a current shunt 92/75-17-1, 92/75-17-6, 92/75-17-9
35 AC current / AC current meters and sources Calibration – electrical quantities
50 Hz, 60 Hz — 10 A to 1000 A · CMC 0,33 %
CMC for the field of measured quantity: Electrical quantities
Comparison or measurement with a standard multimeter with a current transformer 92/75-17-1, 92/75-17-6, 92/75-17-9
36 AC current / clamp testers Calibration – electrical quantities
50 Hz, 60 Hz — 0,1 A to 1000 A · CMC 0,36 % + 0,12 A
CMC for the field of measured quantity: Electrical quantities
Measurement of current simulated by a standard calibrator with current coil 92/75-17-1, 92/75-17-6, 92/75-17-9
37 Electrical resistance / DC resistance standards Calibration – electrical quantities
0,1 mΩ · CMC 0,012 % 1 mΩ · CMC 0,0030 % 10 mΩ · CMC 0,0015 % 0,1 Ω · CMC 0,0015 % 1 Ω · CMC 0,0015 % 10 Ω · CMC 0,0015 % 100 Ω · CMC 0,0015 % 1 kΩ · CMC 0,0015 % 10 kΩ · CMC 0,0015 % 100 kΩ · CMC 0,0015 %
CMC for the field of measured quantity: Electrical quantities
Comparison with the resistance standard by the substitution method 92/75-17-5, 92/75-17-6, 92/75-17-9
38 Electrical resistance / DC resistance meters and generators Calibration – electrical quantities
0,01 Ω to 0,1 Ω · CMC 0,015 % 0,1 Ω to 1 Ω · CMC 0,011 %
CMC for the field of measured quantity: Electrical quantities
Comparison or measurement using the Ohm method 92/75-17-5, 92/75-17-6, 92/75-17-9
39 Electrical resistance / DC resistance meters and generators Calibration – electrical quantities
1 Ω to 20 Ω · CMC 0,0034 % 20 Ω to 200 Ω · CMC 0,0022 % 200 Ω to 20 kΩ · CMC 0,0018 % 20 kΩ to 200 kΩ · CMC 0,0022 % 200 kΩ to 2 MΩ · CMC 0,0040 % 2 MΩ to 20 MΩ · CMC 0,0076 % 20 MΩ to 100 MΩ · CMC 0,058 % 100 MΩ to 1 GΩ · CMC 0,65 % 1 GΩ to 10 GΩ · CMC 1,2 %
CMC for the field of measured quantity: Electrical quantities
Comparison or direct measurement with a standard multimeter 92/75-17-5, 92/75-17-6, 92/75-17-9
40 Electrical resistance / DC resistance meters and generators Calibration – electrical quantities
10 GΩ to 100 GΩ · CMC 3,5 %
CMC for the field of measured quantity: Electrical quantities
Generation by a calibrator of inspection instruments 92/75-17-5, 92/75-17-6, 92/75-17-9
41 DC power / DC wattmeters and DC power generators Calibration – electrical quantities
0,1 V to 1000 V; 1 mA to 20 mA — 0,1 mW to 100 kW · CMC 0,0092 %
CMC for the field of measured quantity: Electrical quantities
Comparison or measurement with two standard multimeters 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9
42 DC power / DC wattmeters and DC power generators Calibration – electrical quantities
0,1 V to 1000 V; 20 mA to 200 mA — 0,1 mW to 100 kW · CMC 0,0065 % 0,1 V to 1000 V; 200 mA to 10 A — 0,1 mW to 100 kW · CMC 0,0070 % 0,1 V to 1000 V; 10 A to 100 A — 0,1 mW to 100 kW · CMC 0,013 %
CMC for the field of measured quantity: Electrical quantities
Comparison or measurement with two standard multimeters and a current shunt 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9
43 DC power / clamp testers Calibration – electrical quantities
0,1 V to 1000 V; 0,1 A to 1000 A — 0,01 W to 1000 kW · CMC 0,36 %
CMC for the field of measured quantity: Electrical quantities
Measurement of power simulated by a standard calibrator with current coil 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9
44 AC power (50 Hz or 60 Hz; power factor 0.5 to 1.0 inductive) / AC wattmeters and AC power generators Calibration – electrical quantities
10 V to 60 V; 20 mA to 10 A — 0,1 W to 12 kW · CMC 0,8 mW/VA 10 V to 60 V; 10 A to 20 A — 0,1 W to 12 kW · CMC 1,3 mW/VA 60 V to 450 V; 20 mA to 10 A — 0,1 W to 12 kW · CMC 0,7 mW/VA 60 V to 450 V; 10 A to 20 A — 0,1 W to 12 kW · CMC 1,2 mW/VA 450 V to 600 V; 20 mA to 10 A — 0,1 W to 12 kW · CMC 0,94 mW/VA 450 V to 600 V; 10 A to 20 A — 0,1 W to 12 kW · CMC 1,7 mW/VA
CMC for the field of measured quantity: Electrical quantities
Comparison or direct measurement with a standard wattmeter 92/75-17-6, 92/75-17-8
45 AC power / clamp testers Calibration – electrical quantities
10 V to 600 V; 0,1 A to 1000 A — 0,5 W to 600 kW · CMC 5,8 mW/VA
CMC for the field of measured quantity: Electrical quantities
Measurement of power simulated by a standard calibrator with current coil 92/75-17-6, 92/75-17-8
46 Frequency / frequency generators Calibration – time and frequency quantities
1 mV to 10 V — 10 Hz to 225 MHz · CMC 0,0014 %
CMC for the field of measured quantity: Time and frequency quantities
Direct measurement by a standard counter 92/75-17-6
47 Frequency / frequency meters Calibration – time and frequency quantities
1 mV to 10 V — 1 Hz to 10 MHz · CMC 0,0050 %
CMC for the field of measured quantity: Time and frequency quantities
Generation with calibrator 92/75-17-6

Reference standards (15)

92/75-14-1
92/75-14-2
92/75-14-3
92/75-14-4
92/75-14-5
92/75-14-6
92/75-15-1
92/75-15-2
92/75-15-3
92/75-17-1
92/75-17-5
92/75-17-6
92/75-17-7
92/75-17-8
92/75-17-9

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2254