{"lab":{"_id":"6ade8b2bff068247617080ff","accr_number":"2254","country":"CZ","accr_body":"ČIA","address":"Jižní Předměstí 2923, 301 00 Plzeň","categories":["metrology"],"city":"Plzeň","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[13.3584104,49.7399354]},"map_coord":[49.7399354,13.3584104],"map_geo":"cai-mapa","methods_count":47,"name":"ENERGIZE GROUP s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: wielkości elektryczne, częstotliwość, ciśnienie, temperatura i wilgotność powietrza, w zakresie określonym w załączniku do świadectwa.","search_text":"energize group s.r.o. jižní předměstí 2923, 301 00 plzeň 2254","source_page_url":"https://www.cai.cz/?subjekt=2254-energize-group-s-r-o","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"21-08-2030","website":"www.energizegroup.cz","certificate_date":"17.03.2026","certificate_no":"127/2026","certificate_replaces":"435/2025 z 21.08.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: wielkości elektryczne, częstotliwość, ciśnienie, temperatura i wilgotność powietrza, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of electrical quantities, frequency, pressure, temperature, and air humidity to the extent as specified in the appendix to this Certificate.","zh":"电学量、频率、压力、温度和空气湿度领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech elektrické veličiny, frekvence, tlak, teplota a vlhkost vzduchu, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"OŚRODEK SŁUŻBY WZORCOWANIA","lab_division_cs":"STŘEDISKO KALIBRAČNÍ SLUŽBY","lab_division_en":"CALIBRATION SERVICE CENTER","lab_division_zh":"校准服务中心","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"69bcbd28ae1b56a3f1725aca6298f4e1cb786e3e2077dcd8dc6acbfecf02eaa6","source_pdf_url":"https://www.cai.cz/OA/pdf/127_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/127_2026_EN.pdf"},"methods":[{"_id":"28b616ca49794dda52f680c9","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia","test_object_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers","test_object_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器","test_object_cs":"Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"medium: powietrze","range":"od -95 kPa do -2,5 kPa","cmc":"60 Pa"}],"parameters_en":[{"name":"medium air","range":"-95 kPa to -2,5 kPa","cmc":"60 Pa"}],"parameters_zh":[{"name":"介质：空气","range":"-95 kPa 至 -2,5 kPa","cmc":"60 Pa"}],"parameters_cs":[{"name":"médium vzduch","range":"-95 kPa až -2,5 kPa","cmc":"60 Pa"}],"technique":"Porównanie z ciśnieniomierzem cyfrowym","technique_en":"Comparison with a digital manometer","technique_zh":"与数字压力计比较","technique_cs":"Porovnání s číslicovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a digital manometer"],"techniques_zh":["与数字压力计比较"],"techniques_cs":["Porovnání s číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nmedium: powietrze od -95 kPa do -2,5 kPa CMC 60 Pa\nPorównanie z ciśnieniomierzem cyfrowym","reference":"92/75-15-1","norm_bases":["92/75-15-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":true,"note":"W przypadku pomiaru ciśnienia bezwzględnego (ciśnienie wynikowe jest sumą ciśnienia barometrycznego i nadciśnienia) CMC pomiaru ciśnienia bezwzględnego stanowi jedną ze składowych niepewności typu B.","note_en":"In the case of absolute pressure measurement (the resulting pressure is the sum of barometric pressure and gauge pressure), the CMC for absolute pressure measurement is one of the components of type B uncertainties.","note_zh":"测量绝对压力时（所得压力为大气压力与表压之和），绝对压力测量的CMC构成B类不确定度分量之一。","note_cs":"V případě měření absolutního tlaku (výsledný tlak je součet tlaku barometrického a přetlaku) CMC měření absolutního tlaku tvoří jednu ze složek nejistot typu B.","search_text":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia Wzorcowanie – ciśnienie, naprężenie mechaniczne Porównanie z ciśnieniomierzem cyfrowym medium: powietrze od -95 kPa do -2,5 kPa CMC 60 Pa Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku Kalibrace – tlak, mechanické napětí Porovnání s číslicovým tlakoměrem médium vzduch -95 kPa až -2,5 kPa CMC 60 Pa 92/75-15-1 Nadcisnienie i cisnienie bezwzgledne / cisnieniomierze sprezyste i cyfrowe oraz przetworniki cisnienia Wzorcowanie – cisnienie, naprezenie mechaniczne Porownanie z cisnieniomierzem cyfrowym medium: powietrze od -95 kPa do -2,5 kPa CMC 60 Pa Pretlak a absolutni tlak / deformacni a cislicove tlakomery a prevodniky tlaku Kalibrace – tlak, mechanicke napeti Porovnani s cislicovym tlakomerem medium vzduch -95 kPa az -2,5 kPa CMC 60 Pa 92/75-15-1","search_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress Comparison with a digital manometer medium air -95 kPa to -2,5 kPa CMC 60 Pa 92/75-15-1","search_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器 校准 – 压力、机械应力 与数字压力计比较 介质：空气 -95 kPa 至 -2,5 kPa CMC 60 Pa 92/75-15-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"198d526afb58215b9c79b799","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia","test_object_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers","test_object_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器","test_object_cs":"Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"medium: powietrze","range":"od -2,5 kPa do 2,5 kPa","cmc":"2 Pa"}],"parameters_en":[{"name":"medium air","range":"-2,5 kPa to 2,5 kPa","cmc":"2 Pa"}],"parameters_zh":[{"name":"介质：空气","range":"-2,5 kPa 至 2,5 kPa","cmc":"2 Pa"}],"parameters_cs":[{"name":"médium vzduch","range":"-2,5 kPa až 2,5 kPa","cmc":"2 Pa"}],"technique":"Porównanie z mikromanometrem","technique_en":"Comparison with a micromanometer","technique_zh":"与微压计比较","technique_cs":"Porovnání s mikromanometrem","techniques":["Porównanie z mikromanometrem"],"techniques_en":["Comparison with a micromanometer"],"techniques_zh":["与微压计比较"],"techniques_cs":["Porovnání s mikromanometrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nmedium: powietrze od -2,5 kPa do 2,5 kPa CMC 2 Pa\nPorównanie z mikromanometrem","reference":"92/75-15-2","norm_bases":["92/75-15-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":true,"note":"W przypadku pomiaru ciśnienia bezwzględnego (ciśnienie wynikowe jest sumą ciśnienia barometrycznego i nadciśnienia) CMC pomiaru ciśnienia bezwzględnego stanowi jedną ze składowych niepewności typu B.","note_en":"In the case of absolute pressure measurement (the resulting pressure is the sum of barometric pressure and gauge pressure), the CMC for absolute pressure measurement is one of the components of type B uncertainties.","note_zh":"测量绝对压力时（所得压力为大气压力与表压之和），绝对压力测量的CMC构成B类不确定度分量之一。","note_cs":"V případě měření absolutního tlaku (výsledný tlak je součet tlaku barometrického a přetlaku) CMC měření absolutního tlaku tvoří jednu ze složek nejistot typu B.","search_text":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia Wzorcowanie – ciśnienie, naprężenie mechaniczne Porównanie z mikromanometrem medium: powietrze od -2,5 kPa do 2,5 kPa CMC 2 Pa Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku Kalibrace – tlak, mechanické napětí Porovnání s mikromanometrem médium vzduch -2,5 kPa až 2,5 kPa CMC 2 Pa 92/75-15-2 Nadcisnienie i cisnienie bezwzgledne / cisnieniomierze sprezyste i cyfrowe oraz przetworniki cisnienia Wzorcowanie – cisnienie, naprezenie mechaniczne Porownanie z mikromanometrem medium: powietrze od -2,5 kPa do 2,5 kPa CMC 2 Pa Pretlak a absolutni tlak / deformacni a cislicove tlakomery a prevodniky tlaku Kalibrace – tlak, mechanicke napeti Porovnani s mikromanometrem medium vzduch -2,5 kPa az 2,5 kPa CMC 2 Pa 92/75-15-2","search_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress Comparison with a micromanometer medium air -2,5 kPa to 2,5 kPa CMC 2 Pa 92/75-15-2","search_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器 校准 – 压力、机械应力 与微压计比较 介质：空气 -2,5 kPa 至 2,5 kPa CMC 2 Pa 92/75-15-2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44785cc27de89221bb134ff6","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia","test_object_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers","test_object_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器","test_object_cs":"Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"medium: azot","range":"od 2,5 kPa do 20 kPa","cmc":"4 Pa"},{"name":"medium: azot","range":"od 20 kPa do 200 kPa","cmc":"2.10⁻⁴"},{"name":"medium: azot","range":"od 0,2 MPa do 1 MPa","cmc":"250 Pa"},{"name":"medium: azot","range":"od 1 MPa do 10 MPa","cmc":"25.10⁻⁵"}],"parameters_en":[{"name":"medium nitrogen","range":"2,5 kPa to 20 kPa","cmc":"4 Pa"},{"name":"medium nitrogen","range":"20 kPa to 200 kPa","cmc":"2.10⁻⁴"},{"name":"medium nitrogen","range":"0,2 MPa to 1 MPa","cmc":"250 Pa"},{"name":"medium nitrogen","range":"1 MPa to 10 MPa","cmc":"25.10⁻⁵"}],"parameters_zh":[{"name":"介质：氮气","range":"2,5 kPa 至 20 kPa","cmc":"4 Pa"},{"name":"介质：氮气","range":"20 kPa 至 200 kPa","cmc":"2.10⁻⁴"},{"name":"介质：氮气","range":"0,2 MPa 至 1 MPa","cmc":"250 Pa"},{"name":"介质：氮气","range":"1 MPa 至 10 MPa","cmc":"25.10⁻⁵"}],"parameters_cs":[{"name":"médium dusík","range":"2,5 kPa až 20 kPa","cmc":"4 Pa"},{"name":"médium dusík","range":"20 kPa až 200 kPa","cmc":"2.10⁻⁴"},{"name":"médium dusík","range":"0,2 MPa až 1 MPa","cmc":"250 Pa"},{"name":"médium dusík","range":"1 MPa až 10 MPa","cmc":"25.10⁻⁵"}],"technique":"Porównanie z ciśnieniomierzem kulowym","technique_en":"Comparison with a ball manometer","technique_zh":"与球式压力计比较","technique_cs":"Porovnání s kuličkovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem kulowym"],"techniques_en":["Comparison with a ball manometer"],"techniques_zh":["与球式压力计比较"],"techniques_cs":["Porovnání s kuličkovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nZakres:\nmedium: azot od 2,5 kPa do 20 kPa CMC 4 Pa\nmedium: azot od 20 kPa do 200 kPa CMC 2.10⁻⁴\nmedium: azot od 0,2 MPa do 1 MPa CMC 250 Pa\nmedium: azot od 1 MPa do 10 MPa CMC 25.10⁻⁵\nPorównanie z ciśnieniomierzem kulowym","reference":"92/75-15-3","norm_bases":["92/75-15-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":true,"note":"W przypadku pomiaru ciśnienia bezwzględnego (ciśnienie wynikowe jest sumą ciśnienia barometrycznego i nadciśnienia) CMC pomiaru ciśnienia bezwzględnego stanowi jedną ze składowych niepewności typu B.","note_en":"In the case of absolute pressure measurement (the resulting pressure is the sum of barometric pressure and gauge pressure), the CMC for absolute pressure measurement is one of the components of type B uncertainties.","note_zh":"测量绝对压力时（所得压力为大气压力与表压之和），绝对压力测量的CMC构成B类不确定度分量之一。","note_cs":"V případě měření absolutního tlaku (výsledný tlak je součet tlaku barometrického a přetlaku) CMC měření absolutního tlaku tvoří jednu ze složek nejistot typu B.","search_text":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia Wzorcowanie – ciśnienie, naprężenie mechaniczne Porównanie z ciśnieniomierzem kulowym medium: azot od 2,5 kPa do 20 kPa CMC 4 Pa medium: azot od 20 kPa do 200 kPa CMC 2.10⁻⁴ medium: azot od 0,2 MPa do 1 MPa CMC 250 Pa medium: azot od 1 MPa do 10 MPa CMC 25.10⁻⁵ Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku Kalibrace – tlak, mechanické napětí Porovnání s kuličkovým tlakoměrem médium dusík 2,5 kPa až 20 kPa CMC 4 Pa médium dusík 20 kPa až 200 kPa CMC 2.10⁻⁴ médium dusík 0,2 MPa až 1 MPa CMC 250 Pa médium dusík 1 MPa až 10 MPa CMC 25.10⁻⁵ 92/75-15-3 Nadcisnienie i cisnienie bezwzgledne / cisnieniomierze sprezyste i cyfrowe oraz przetworniki cisnienia Wzorcowanie – cisnienie, naprezenie mechaniczne Porownanie z cisnieniomierzem kulowym medium: azot od 2,5 kPa do 20 kPa CMC 4 Pa medium: azot od 20 kPa do 200 kPa CMC 2.10⁻⁴ medium: azot od 0,2 MPa do 1 MPa CMC 250 Pa medium: azot od 1 MPa do 10 MPa CMC 25.10⁻⁵ Pretlak a absolutni tlak / deformacni a cislicove tlakomery a prevodniky tlaku Kalibrace – tlak, mechanicke napeti Porovnani s kulickovym tlakomerem medium dusik 2,5 kPa az 20 kPa CMC 4 Pa medium dusik 20 kPa az 200 kPa CMC 2.10⁻⁴ medium dusik 0,2 MPa az 1 MPa CMC 250 Pa medium dusik 1 MPa az 10 MPa CMC 25.10⁻⁵ 92/75-15-3","search_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress Comparison with a ball manometer medium nitrogen 2,5 kPa to 20 kPa CMC 4 Pa medium nitrogen 20 kPa to 200 kPa CMC 2.10⁻⁴ medium nitrogen 0,2 MPa to 1 MPa CMC 250 Pa medium nitrogen 1 MPa to 10 MPa CMC 25.10⁻⁵ 92/75-15-3","search_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器 校准 – 压力、机械应力 与球式压力计比较 介质：氮气 2,5 kPa 至 20 kPa CMC 4 Pa 介质：氮气 20 kPa 至 200 kPa CMC 2.10⁻⁴ 介质：氮气 0,2 MPa 至 1 MPa CMC 250 Pa 介质：氮气 1 MPa 至 10 MPa CMC 25.10⁻⁵ 92/75-15-3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"668eebbf2c6aab6f1ae10f1c","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia","test_object_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers","test_object_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器","test_object_cs":"Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"medium: olej","range":"od 0,025 MPa do 0,6 MPa","cmc":"300 Pa"}],"parameters_en":[{"name":"medium oil","range":"0,025 MPa to 0,6 MPa","cmc":"300 Pa"}],"parameters_zh":[{"name":"介质：油","range":"0,025 MPa 至 0,6 MPa","cmc":"300 Pa"}],"parameters_cs":[{"name":"médium olej","range":"0,025 MPa až 0,6 MPa","cmc":"300 Pa"}],"technique":"Porównanie z ciśnieniomierzem obciążnikowo-tłokowym","technique_en":"Comparison with a piston manometer","technique_zh":"与活塞式压力计比较","technique_cs":"Porovnání s pístovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem obciążnikowo-tłokowym"],"techniques_en":["Comparison with a piston manometer"],"techniques_zh":["与活塞式压力计比较"],"techniques_cs":["Porovnání s pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nmedium: olej od 0,025 MPa do 0,6 MPa CMC 300 Pa\nPorównanie z ciśnieniomierzem obciążnikowo-tłokowym","reference":"92/75-15-1, 92/75-15-2","norm_bases":["92/75-15-1","92/75-15-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":true,"note":"W przypadku pomiaru ciśnienia bezwzględnego (ciśnienie wynikowe jest sumą ciśnienia barometrycznego i nadciśnienia) CMC pomiaru ciśnienia bezwzględnego stanowi jedną ze składowych niepewności typu B.","note_en":"In the case of absolute pressure measurement (the resulting pressure is the sum of barometric pressure and gauge pressure), the CMC for absolute pressure measurement is one of the components of type B uncertainties.","note_zh":"测量绝对压力时（所得压力为大气压力与表压之和），绝对压力测量的CMC构成B类不确定度分量之一。","note_cs":"V případě měření absolutního tlaku (výsledný tlak je součet tlaku barometrického a přetlaku) CMC měření absolutního tlaku tvoří jednu ze složek nejistot typu B.","search_text":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia Wzorcowanie – ciśnienie, naprężenie mechaniczne Porównanie z ciśnieniomierzem obciążnikowo-tłokowym medium: olej od 0,025 MPa do 0,6 MPa CMC 300 Pa Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku Kalibrace – tlak, mechanické napětí Porovnání s pístovým tlakoměrem médium olej 0,025 MPa až 0,6 MPa CMC 300 Pa 92/75-15-1, 92/75-15-2 Nadcisnienie i cisnienie bezwzgledne / cisnieniomierze sprezyste i cyfrowe oraz przetworniki cisnienia Wzorcowanie – cisnienie, naprezenie mechaniczne Porownanie z cisnieniomierzem obciaznikowo-tlokowym medium: olej od 0,025 MPa do 0,6 MPa CMC 300 Pa Pretlak a absolutni tlak / deformacni a cislicove tlakomery a prevodniky tlaku Kalibrace – tlak, mechanicke napeti Porovnani s pistovym tlakomerem medium olej 0,025 MPa az 0,6 MPa CMC 300 Pa 92/75-15-1, 92/75-15-2","search_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress Comparison with a piston manometer medium oil 0,025 MPa to 0,6 MPa CMC 300 Pa 92/75-15-1, 92/75-15-2","search_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器 校准 – 压力、机械应力 与活塞式压力计比较 介质：油 0,025 MPa 至 0,6 MPa CMC 300 Pa 92/75-15-1, 92/75-15-2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43419549fe00ca4fd8f1dc59","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia","test_object_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers","test_object_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器","test_object_cs":"Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"medium: olej","range":"od 0,6 MPa do 60 MPa","cmc":"5.10⁻⁴"}],"parameters_en":[{"name":"medium oil","range":"0,6 MPa to 60 MPa","cmc":"5.10⁻⁴"}],"parameters_zh":[{"name":"介质：油","range":"0,6 MPa 至 60 MPa","cmc":"5.10⁻⁴"}],"parameters_cs":[{"name":"médium olej","range":"0,6 MPa až 60 MPa","cmc":"5.10⁻⁴"}],"technique":"Porównanie z ciśnieniomierzem obciążnikowo-tłokowym","technique_en":"Comparison with a piston manometer","technique_zh":"与活塞式压力计比较","technique_cs":"Porovnání s pístovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem obciążnikowo-tłokowym"],"techniques_en":["Comparison with a piston manometer"],"techniques_zh":["与活塞式压力计比较"],"techniques_cs":["Porovnání s pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nmedium: olej od 0,6 MPa do 60 MPa CMC 5.10⁻⁴\nPorównanie z ciśnieniomierzem obciążnikowo-tłokowym","reference":"92/75-15-3","norm_bases":["92/75-15-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":true,"note":"W przypadku pomiaru ciśnienia bezwzględnego (ciśnienie wynikowe jest sumą ciśnienia barometrycznego i nadciśnienia) CMC pomiaru ciśnienia bezwzględnego stanowi jedną ze składowych niepewności typu B.","note_en":"In the case of absolute pressure measurement (the resulting pressure is the sum of barometric pressure and gauge pressure), the CMC for absolute pressure measurement is one of the components of type B uncertainties.","note_zh":"测量绝对压力时（所得压力为大气压力与表压之和），绝对压力测量的CMC构成B类不确定度分量之一。","note_cs":"V případě měření absolutního tlaku (výsledný tlak je součet tlaku barometrického a přetlaku) CMC měření absolutního tlaku tvoří jednu ze složek nejistot typu B.","search_text":"Nadciśnienie i ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia Wzorcowanie – ciśnienie, naprężenie mechaniczne Porównanie z ciśnieniomierzem obciążnikowo-tłokowym medium: olej od 0,6 MPa do 60 MPa CMC 5.10⁻⁴ Přetlak a absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku Kalibrace – tlak, mechanické napětí Porovnání s pístovým tlakoměrem médium olej 0,6 MPa až 60 MPa CMC 5.10⁻⁴ 92/75-15-3 Nadcisnienie i cisnienie bezwzgledne / cisnieniomierze sprezyste i cyfrowe oraz przetworniki cisnienia Wzorcowanie – cisnienie, naprezenie mechaniczne Porownanie z cisnieniomierzem obciaznikowo-tlokowym medium: olej od 0,6 MPa do 60 MPa CMC 5.10⁻⁴ Pretlak a absolutni tlak / deformacni a cislicove tlakomery a prevodniky tlaku Kalibrace – tlak, mechanicke napeti Porovnani s pistovym tlakomerem medium olej 0,6 MPa az 60 MPa CMC 5.10⁻⁴ 92/75-15-3","search_en":"Gauge pressure and absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress Comparison with a piston manometer medium oil 0,6 MPa to 60 MPa CMC 5.10⁻⁴ 92/75-15-3","search_zh":"表压和绝对压力 / 弹性式和数字式压力表及压力变送器 校准 – 压力、机械应力 与活塞式压力计比较 介质：油 0,6 MPa 至 60 MPa CMC 5.10⁻⁴ 92/75-15-3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c7dec1e3f9e4a35095395ac0","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"3","test_object":"Ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia","test_object_en":"Absolute pressure / deformation and digital manometers and pressure transducers","test_object_zh":"绝对压力 / 弹性式和数字式压力表及压力变送器","test_object_cs":"Absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku","methodology":"Wzorcowanie – ciśnienie, naprężenie mechaniczne","methodology_en":"Calibration – pressure, mechanical stress","methodology_zh":"校准 – 压力、机械应力","methodology_cs":"Kalibrace – tlak, mechanické napětí","parameters":[{"name":"medium: powietrze","range":"od 0 kPa do 100 kPa","cmc":"26 Pa"},{"name":"medium: powietrze","range":"od 100 kPa do 200 kPa","cmc":"1.10⁻⁴ + 23 Pa"}],"parameters_en":[{"name":"medium air","range":"0 kPa to 100 kPa","cmc":"26 Pa"},{"name":"medium air","range":"100 kPa to 200 kPa","cmc":"1.10⁻⁴ + 23 Pa"}],"parameters_zh":[{"name":"介质：空气","range":"0 kPa 至 100 kPa","cmc":"26 Pa"},{"name":"介质：空气","range":"100 kPa 至 200 kPa","cmc":"1.10⁻⁴ + 23 Pa"}],"parameters_cs":[{"name":"médium vzduch","range":"0 kPa až 100 kPa","cmc":"26 Pa"},{"name":"médium vzduch","range":"100 kPa až 200 kPa","cmc":"1.10⁻⁴ + 23 Pa"}],"technique":"Porównanie z ciśnieniomierzem cyfrowym","technique_en":"Comparison with a digital manometer","technique_zh":"与数字压力计比较","technique_cs":"Porovnání s číslicovým tlakoměrem","techniques":["Porównanie z ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a digital manometer"],"techniques_zh":["与数字压力计比较"],"techniques_cs":["Porovnání s číslicovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie, naprężenie mechaniczne\nZakres:\nmedium: powietrze od 0 kPa do 100 kPa CMC 26 Pa\nmedium: powietrze od 100 kPa do 200 kPa CMC 1.10⁻⁴ + 23 Pa\nPorównanie z ciśnieniomierzem cyfrowym","reference":"92/75-15-1, 92/75-15-2, 92/75-15-3","norm_bases":["92/75-15-1","92/75-15-2","92/75-15-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie, naprężenie mechaniczne","regulatory_area_en":"CMC for the field of measured quantity: Pressure, mechanical stress","regulatory_area_zh":"被测量领域的CMC：压力、机械应力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak, mechanické napětí","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnienie bezwzględne / ciśnieniomierze sprężyste i cyfrowe oraz przetworniki ciśnienia Wzorcowanie – ciśnienie, naprężenie mechaniczne Porównanie z ciśnieniomierzem cyfrowym medium: powietrze od 0 kPa do 100 kPa CMC 26 Pa medium: powietrze od 100 kPa do 200 kPa CMC 1.10⁻⁴ + 23 Pa Absolutní tlak / deformační a číslicové tlakoměry a převodníky tlaku Kalibrace – tlak, mechanické napětí Porovnání s číslicovým tlakoměrem médium vzduch 0 kPa až 100 kPa CMC 26 Pa médium vzduch 100 kPa až 200 kPa CMC 1.10⁻⁴ + 23 Pa 92/75-15-1, 92/75-15-2, 92/75-15-3 Cisnienie bezwzgledne / cisnieniomierze sprezyste i cyfrowe oraz przetworniki cisnienia Wzorcowanie – cisnienie, naprezenie mechaniczne Porownanie z cisnieniomierzem cyfrowym medium: powietrze od 0 kPa do 100 kPa CMC 26 Pa medium: powietrze od 100 kPa do 200 kPa CMC 1.10⁻⁴ + 23 Pa Absolutni tlak / deformacni a cislicove tlakomery a prevodniky tlaku Kalibrace – tlak, mechanicke napeti Porovnani s cislicovym tlakomerem medium vzduch 0 kPa az 100 kPa CMC 26 Pa medium vzduch 100 kPa az 200 kPa CMC 1.10⁻⁴ + 23 Pa 92/75-15-1, 92/75-15-2, 92/75-15-3","search_en":"Absolute pressure / deformation and digital manometers and pressure transducers Calibration – pressure, mechanical stress Comparison with a digital manometer medium air 0 kPa to 100 kPa CMC 26 Pa medium air 100 kPa to 200 kPa CMC 1.10⁻⁴ + 23 Pa 92/75-15-1, 92/75-15-2, 92/75-15-3","search_zh":"绝对压力 / 弹性式和数字式压力表及压力变送器 校准 – 压力、机械应力 与数字压力计比较 介质：空气 0 kPa 至 100 kPa CMC 26 Pa 介质：空气 100 kPa 至 200 kPa CMC 1.10⁻⁴ + 23 Pa 92/75-15-1, 92/75-15-2, 92/75-15-3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"597442d0d98b1a920c8b0a68","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Termopara S","test_object_en":"Thermocouple S","test_object_zh":"S 型热电偶","test_object_cs":"Termočlánek S","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 100 °C do 500 °C","cmc":"0,70 °C"}],"parameters_en":[{"name":"","range":"100 °C to 500 °C","cmc":"0,70 °C"}],"parameters_zh":[{"name":"","range":"100 °C 至 500 °C","cmc":"0,70 °C"}],"parameters_cs":[{"name":"","range":"100 °C až 500 °C","cmc":"0,70 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","technique_en":"Comparison with a standard resistance sensor in a calibrating oven","technique_zh":"在校准炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kalibrační pícce","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard resistance sensor in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 100 °C do 500 °C CMC 0,70 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","reference":"92/75-14-1","norm_bases":["92/75-14-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopara S Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 100 °C do 500 °C CMC 0,70 °C Termočlánek S Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kalibrační pícce 100 °C až 500 °C CMC 0,70 °C 92/75-14-1 Termopara S Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 100 °C do 500 °C CMC 0,70 °C Termoclanek S Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kalibracni picce 100 °C az 500 °C CMC 0,70 °C 92/75-14-1","search_en":"Thermocouple S Calibration – temperature Comparison with a standard resistance sensor in a calibrating oven 100 °C to 500 °C CMC 0,70 °C 92/75-14-1","search_zh":"S 型热电偶 校准 – 温度 在校准炉中与标准电阻传感器比较 100 °C 至 500 °C CMC 0,70 °C 92/75-14-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc416af0356578eb6c8ebb9c","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Termopara S","test_object_en":"Thermocouple S","test_object_zh":"S 型热电偶","test_object_cs":"Termočlánek S","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 400 °C do 1100 °C","cmc":"1,6 °C"}],"parameters_en":[{"name":"","range":"400 °C to 1100 °C","cmc":"1,6 °C"}],"parameters_zh":[{"name":"","range":"400 °C 至 1100 °C","cmc":"1,6 °C"}],"parameters_cs":[{"name":"","range":"400 °C až 1100 °C","cmc":"1,6 °C"}],"technique":"Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym","technique_en":"Comparison with a standard thermoelectric sensor in a horizontal furnace","technique_zh":"在卧式炉中与标准热电偶传感器比较","technique_cs":"Porovnání s etalonovým termoelektrickým snímačem v horizontální peci","techniques":["Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym"],"techniques_en":["Comparison with a standard thermoelectric sensor in a horizontal furnace"],"techniques_zh":["在卧式炉中与标准热电偶传感器比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým snímačem v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 400 °C do 1100 °C CMC 1,6 °C\nPorównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym","reference":"92/75-14-1","norm_bases":["92/75-14-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopara S Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym od 400 °C do 1100 °C CMC 1,6 °C Termočlánek S Kalibrace – teplota Porovnání s etalonovým termoelektrickým snímačem v horizontální peci 400 °C až 1100 °C CMC 1,6 °C 92/75-14-1 Termopara S Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym od 400 °C do 1100 °C CMC 1,6 °C Termoclanek S Kalibrace – teplota Porovnani s etalonovym termoelektrickym snimacem v horizontalni peci 400 °C az 1100 °C CMC 1,6 °C 92/75-14-1","search_en":"Thermocouple S Calibration – temperature Comparison with a standard thermoelectric sensor in a horizontal furnace 400 °C to 1100 °C CMC 1,6 °C 92/75-14-1","search_zh":"S 型热电偶 校准 – 温度 在卧式炉中与标准热电偶传感器比较 400 °C 至 1100 °C CMC 1,6 °C 92/75-14-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7d31f9c9bac4bc2d7ee76b25","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Termopara – metale nieszlachetne","test_object_en":"Thermocouple - base metals","test_object_zh":"廉金属热电偶","test_object_cs":"Termočlánek-obecné kovy","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 0 °C do 30 °C","cmc":"0,40 °C"},{"name":"","range":"od 200 °C do 500 °C","cmc":"0,63 °C"}],"parameters_en":[{"name":"","range":"0 °C to 30 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C to 500 °C","cmc":"0,63 °C"}],"parameters_zh":[{"name":"","range":"0 °C 至 30 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C 至 500 °C","cmc":"0,63 °C"}],"parameters_cs":[{"name":"","range":"0 °C až 30 °C","cmc":"0,40 °C"},{"name":"","range":"200 °C až 500 °C","cmc":"0,63 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","technique_en":"Comparison with a standard resistance sensor in a calibrating oven","technique_zh":"在校准炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kalibrační pícce","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard resistance sensor in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod 0 °C do 30 °C CMC 0,40 °C\nod 200 °C do 500 °C CMC 0,63 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","reference":"92/75-14-1","norm_bases":["92/75-14-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopara – metale nieszlachetne Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 0 °C do 30 °C CMC 0,40 °C od 200 °C do 500 °C CMC 0,63 °C Termočlánek-obecné kovy Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kalibrační pícce 0 °C až 30 °C CMC 0,40 °C 200 °C až 500 °C CMC 0,63 °C 92/75-14-1 Termopara – metale nieszlachetne Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 0 °C do 30 °C CMC 0,40 °C od 200 °C do 500 °C CMC 0,63 °C Termoclanek-obecne kovy Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kalibracni picce 0 °C az 30 °C CMC 0,40 °C 200 °C az 500 °C CMC 0,63 °C 92/75-14-1","search_en":"Thermocouple - base metals Calibration – temperature Comparison with a standard resistance sensor in a calibrating oven 0 °C to 30 °C CMC 0,40 °C 200 °C to 500 °C CMC 0,63 °C 92/75-14-1","search_zh":"廉金属热电偶 校准 – 温度 在校准炉中与标准电阻传感器比较 0 °C 至 30 °C CMC 0,40 °C 200 °C 至 500 °C CMC 0,63 °C 92/75-14-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b392bd354df2411ed6e6bb29","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Termopara – metale nieszlachetne","test_object_en":"Thermocouple - base metals","test_object_zh":"廉金属热电偶","test_object_cs":"Termočlánek-obecné kovy","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 30 °C do 200 °C","cmc":"0,43 °C"}],"parameters_en":[{"name":"","range":"30 °C to 200 °C","cmc":"0,43 °C"}],"parameters_zh":[{"name":"","range":"30 °C 至 200 °C","cmc":"0,43 °C"}],"parameters_cs":[{"name":"","range":"30 °C až 200 °C","cmc":"0,43 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","technique_en":"Comparison with a standard resistance sensor in an oil bath","technique_zh":"在油槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v olejové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej"],"techniques_en":["Comparison with a standard resistance sensor in an oil bath"],"techniques_zh":["在油槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v olejové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 30 °C do 200 °C CMC 0,43 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","reference":"92/75-14-1","norm_bases":["92/75-14-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopara – metale nieszlachetne Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej od 30 °C do 200 °C CMC 0,43 °C Termočlánek-obecné kovy Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v olejové lázni 30 °C až 200 °C CMC 0,43 °C 92/75-14-1 Termopara – metale nieszlachetne Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni olejowej od 30 °C do 200 °C CMC 0,43 °C Termoclanek-obecne kovy Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v olejove lazni 30 °C az 200 °C CMC 0,43 °C 92/75-14-1","search_en":"Thermocouple - base metals Calibration – temperature Comparison with a standard resistance sensor in an oil bath 30 °C to 200 °C CMC 0,43 °C 92/75-14-1","search_zh":"廉金属热电偶 校准 – 温度 在油槽中与标准电阻传感器比较 30 °C 至 200 °C CMC 0,43 °C 92/75-14-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f3c160b5284eef12375a1a0e","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Termopara – metale nieszlachetne","test_object_en":"Thermocouple - base metals","test_object_zh":"廉金属热电偶","test_object_cs":"Termočlánek-obecné kovy","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 500 °C do 1100 °C","cmc":"1,6 °C"}],"parameters_en":[{"name":"","range":"500 °C to 1100 °C","cmc":"1,6 °C"}],"parameters_zh":[{"name":"","range":"500 °C 至 1100 °C","cmc":"1,6 °C"}],"parameters_cs":[{"name":"","range":"500 °C až 1100 °C","cmc":"1,6 °C"}],"technique":"Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym","technique_en":"Comparison with a standard thermoelectric sensor in a horizontal furnace","technique_zh":"在卧式炉中与标准热电偶传感器比较","technique_cs":"Porovnání s etalonovým termoelektrickým snímačem v horizontální peci","techniques":["Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym"],"techniques_en":["Comparison with a standard thermoelectric sensor in a horizontal furnace"],"techniques_zh":["在卧式炉中与标准热电偶传感器比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým snímačem v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 500 °C do 1100 °C CMC 1,6 °C\nPorównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym","reference":"92/75-14-1","norm_bases":["92/75-14-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termopara – metale nieszlachetne Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym od 500 °C do 1100 °C CMC 1,6 °C Termočlánek-obecné kovy Kalibrace – teplota Porovnání s etalonovým termoelektrickým snímačem v horizontální peci 500 °C až 1100 °C CMC 1,6 °C 92/75-14-1 Termopara – metale nieszlachetne Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym od 500 °C do 1100 °C CMC 1,6 °C Termoclanek-obecne kovy Kalibrace – teplota Porovnani s etalonovym termoelektrickym snimacem v horizontalni peci 500 °C az 1100 °C CMC 1,6 °C 92/75-14-1","search_en":"Thermocouple - base metals Calibration – temperature Comparison with a standard thermoelectric sensor in a horizontal furnace 500 °C to 1100 °C CMC 1,6 °C 92/75-14-1","search_zh":"廉金属热电偶 校准 – 温度 在卧式炉中与标准热电偶传感器比较 500 °C 至 1100 °C CMC 1,6 °C 92/75-14-1","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4e18fbf68d71f6218d767d2","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"3","test_object":"Termometr rezystancyjny","test_object_en":"Resistance thermometer","test_object_zh":"电阻温度计","test_object_cs":"Odporový teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 30 °C","cmc":"0,27 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 30 °C","cmc":"0,27 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 30 °C","cmc":"0,27 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 30 °C","cmc":"0,27 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej","technique_en":"Comparison with a standard resistance sensor in a climatic chamber","technique_zh":"在气候箱中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v klimatické komoře","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej"],"techniques_en":["Comparison with a standard resistance sensor in a climatic chamber"],"techniques_zh":["在气候箱中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -30 °C do 30 °C CMC 0,27 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej","reference":"92/75-14-2","norm_bases":["92/75-14-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr rezystancyjny Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej od -30 °C do 30 °C CMC 0,27 °C Odporový teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v klimatické komoře -30 °C až 30 °C CMC 0,27 °C 92/75-14-2 Termometr rezystancyjny Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej od -30 °C do 30 °C CMC 0,27 °C Odporovy teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v klimaticke komore -30 °C az 30 °C CMC 0,27 °C 92/75-14-2","search_en":"Resistance thermometer Calibration – temperature Comparison with a standard resistance sensor in a climatic chamber -30 °C to 30 °C CMC 0,27 °C 92/75-14-2","search_zh":"电阻温度计 校准 – 温度 在气候箱中与标准电阻传感器比较 -30 °C 至 30 °C CMC 0,27 °C 92/75-14-2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4a5ff9d4aecee5dacd223dd","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"3","test_object":"Termometr rezystancyjny","test_object_en":"Resistance thermometer","test_object_zh":"电阻温度计","test_object_cs":"Odporový teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 30 °C do 200 °C","cmc":"0,16 °C"}],"parameters_en":[{"name":"","range":"30 °C to 200 °C","cmc":"0,16 °C"}],"parameters_zh":[{"name":"","range":"30 °C 至 200 °C","cmc":"0,16 °C"}],"parameters_cs":[{"name":"","range":"30 °C až 200 °C","cmc":"0,16 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","technique_en":"Comparison with a standard resistance sensor in an oil bath","technique_zh":"在油槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v olejové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej"],"techniques_en":["Comparison with a standard resistance sensor in an oil bath"],"techniques_zh":["在油槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v olejové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 30 °C do 200 °C CMC 0,16 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","reference":"92/75-14-2","norm_bases":["92/75-14-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr rezystancyjny Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej od 30 °C do 200 °C CMC 0,16 °C Odporový teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v olejové lázni 30 °C až 200 °C CMC 0,16 °C 92/75-14-2 Termometr rezystancyjny Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni olejowej od 30 °C do 200 °C CMC 0,16 °C Odporovy teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v olejove lazni 30 °C az 200 °C CMC 0,16 °C 92/75-14-2","search_en":"Resistance thermometer Calibration – temperature Comparison with a standard resistance sensor in an oil bath 30 °C to 200 °C CMC 0,16 °C 92/75-14-2","search_zh":"电阻温度计 校准 – 温度 在油槽中与标准电阻传感器比较 30 °C 至 200 °C CMC 0,16 °C 92/75-14-2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f18c65278aaafe86016d6076","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"3","test_object":"Termometr rezystancyjny","test_object_en":"Resistance thermometer","test_object_zh":"电阻温度计","test_object_cs":"Odporový teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 500 °C","cmc":"0,53 °C"}],"parameters_en":[{"name":"","range":"200 °C to 500 °C","cmc":"0,53 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 500 °C","cmc":"0,53 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 500 °C","cmc":"0,53 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","technique_en":"Comparison with a standard resistance sensor in a calibrating oven","technique_zh":"在校准炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kalibrační pícce","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard resistance sensor in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 200 °C do 500 °C CMC 0,53 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","reference":"92/75-14-2","norm_bases":["92/75-14-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr rezystancyjny Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 200 °C do 500 °C CMC 0,53 °C Odporový teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kalibrační pícce 200 °C až 500 °C CMC 0,53 °C 92/75-14-2 Termometr rezystancyjny Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 200 °C do 500 °C CMC 0,53 °C Odporovy teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kalibracni picce 200 °C az 500 °C CMC 0,53 °C 92/75-14-2","search_en":"Resistance thermometer Calibration – temperature Comparison with a standard resistance sensor in a calibrating oven 200 °C to 500 °C CMC 0,53 °C 92/75-14-2","search_zh":"电阻温度计 校准 – 温度 在校准炉中与标准电阻传感器比较 200 °C 至 500 °C CMC 0,53 °C 92/75-14-2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bb16389f115dc304457b8425","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"4","test_object":"Termometr szklany","test_object_en":"Glass thermometer","test_object_zh":"玻璃温度计","test_object_cs":"Skleněný teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0 °C","cmc":"0,11 °C"}],"parameters_en":[{"name":"","range":"0 °C","cmc":"0,11 °C"}],"parameters_zh":[{"name":"","range":"0 °C","cmc":"0,11 °C"}],"parameters_cs":[{"name":"","range":"0 °C","cmc":"0,11 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu Dewara","technique_en":"Comparison with a standard resistance sensor in a Dewar flask","technique_zh":"在杜瓦瓶中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v Dewarově nádobě","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu Dewara"],"techniques_en":["Comparison with a standard resistance sensor in a Dewar flask"],"techniques_zh":["在杜瓦瓶中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v Dewarově nádobě"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0 °C CMC 0,11 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu Dewara","reference":"92/75-14-3","norm_bases":["92/75-14-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr szklany Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w naczyniu Dewara 0 °C CMC 0,11 °C Skleněný teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v Dewarově nádobě 0 °C CMC 0,11 °C 92/75-14-3 Termometr szklany Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w naczyniu Dewara 0 °C CMC 0,11 °C Skleneny teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v Dewarove nadobe 0 °C CMC 0,11 °C 92/75-14-3","search_en":"Glass thermometer Calibration – temperature Comparison with a standard resistance sensor in a Dewar flask 0 °C CMC 0,11 °C 92/75-14-3","search_zh":"玻璃温度计 校准 – 温度 在杜瓦瓶中与标准电阻传感器比较 0 °C CMC 0,11 °C 92/75-14-3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"99767f2a48433329eb19d3fc","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"4","test_object":"Termometr szklany","test_object_en":"Glass thermometer","test_object_zh":"玻璃温度计","test_object_cs":"Skleněný teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 30 °C do 200 °C","cmc":"0,15 °C"}],"parameters_en":[{"name":"","range":"30 °C to 200 °C","cmc":"0,15 °C"}],"parameters_zh":[{"name":"","range":"30 °C 至 200 °C","cmc":"0,15 °C"}],"parameters_cs":[{"name":"","range":"30 °C až 200 °C","cmc":"0,15 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","technique_en":"Comparison with a standard resistance sensor in an oil bath","technique_zh":"在油槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v olejové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej"],"techniques_en":["Comparison with a standard resistance sensor in an oil bath"],"techniques_zh":["在油槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v olejové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 30 °C do 200 °C CMC 0,15 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","reference":"92/75-14-3","norm_bases":["92/75-14-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr szklany Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej od 30 °C do 200 °C CMC 0,15 °C Skleněný teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v olejové lázni 30 °C až 200 °C CMC 0,15 °C 92/75-14-3 Termometr szklany Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni olejowej od 30 °C do 200 °C CMC 0,15 °C Skleneny teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v olejove lazni 30 °C az 200 °C CMC 0,15 °C 92/75-14-3","search_en":"Glass thermometer Calibration – temperature Comparison with a standard resistance sensor in an oil bath 30 °C to 200 °C CMC 0,15 °C 92/75-14-3","search_zh":"玻璃温度计 校准 – 温度 在油槽中与标准电阻传感器比较 30 °C 至 200 °C CMC 0,15 °C 92/75-14-3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c1298c7166a066247912e67e","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Termometr analogowy i cyfrowy","test_object_en":"Analogue and digital thermometer","test_object_zh":"模拟和数字温度计","test_object_cs":"Analogový a digitální teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 30 °C","cmc":"0,27 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 30 °C","cmc":"0,27 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 30 °C","cmc":"0,27 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 30 °C","cmc":"0,27 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej","technique_en":"Comparison with a standard resistance sensor in a climatic chamber","technique_zh":"在气候箱中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v klimatické komoře","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej"],"techniques_en":["Comparison with a standard resistance sensor in a climatic chamber"],"techniques_zh":["在气候箱中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod -30 °C do 30 °C CMC 0,27 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej","reference":"92/75-14-4","norm_bases":["92/75-14-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej od -30 °C do 30 °C CMC 0,27 °C Analogový a digitální teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v klimatické komoře -30 °C až 30 °C CMC 0,27 °C 92/75-14-4 Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w komorze klimatycznej od -30 °C do 30 °C CMC 0,27 °C Analogovy a digitalni teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v klimaticke komore -30 °C az 30 °C CMC 0,27 °C 92/75-14-4","search_en":"Analogue and digital thermometer Calibration – temperature Comparison with a standard resistance sensor in a climatic chamber -30 °C to 30 °C CMC 0,27 °C 92/75-14-4","search_zh":"模拟和数字温度计 校准 – 温度 在气候箱中与标准电阻传感器比较 -30 °C 至 30 °C CMC 0,27 °C 92/75-14-4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"19f6d70c17d1ae0913a009ad","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Termometr analogowy i cyfrowy","test_object_en":"Analogue and digital thermometer","test_object_zh":"模拟和数字温度计","test_object_cs":"Analogový a digitální teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 30 °C do 200 °C","cmc":"0,16 °C"}],"parameters_en":[{"name":"","range":"30 °C to 200 °C","cmc":"0,16 °C"}],"parameters_zh":[{"name":"","range":"30 °C 至 200 °C","cmc":"0,16 °C"}],"parameters_cs":[{"name":"","range":"30 °C až 200 °C","cmc":"0,16 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","technique_en":"Comparison with a standard resistance sensor in an oil bath","technique_zh":"在油槽中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v olejové lázni","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej"],"techniques_en":["Comparison with a standard resistance sensor in an oil bath"],"techniques_zh":["在油槽中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v olejové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 30 °C do 200 °C CMC 0,16 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej","reference":"92/75-14-4","norm_bases":["92/75-14-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w łaźni olejowej od 30 °C do 200 °C CMC 0,16 °C Analogový a digitální teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v olejové lázni 30 °C až 200 °C CMC 0,16 °C 92/75-14-4 Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w lazni olejowej od 30 °C do 200 °C CMC 0,16 °C Analogovy a digitalni teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v olejove lazni 30 °C az 200 °C CMC 0,16 °C 92/75-14-4","search_en":"Analogue and digital thermometer Calibration – temperature Comparison with a standard resistance sensor in an oil bath 30 °C to 200 °C CMC 0,16 °C 92/75-14-4","search_zh":"模拟和数字温度计 校准 – 温度 在油槽中与标准电阻传感器比较 30 °C 至 200 °C CMC 0,16 °C 92/75-14-4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"649e0b7a84a799518c04f498","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Termometr analogowy i cyfrowy","test_object_en":"Analogue and digital thermometer","test_object_zh":"模拟和数字温度计","test_object_cs":"Analogový a digitální teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 200 °C do 500 °C","cmc":"0,53 °C"}],"parameters_en":[{"name":"","range":"200 °C to 500 °C","cmc":"0,53 °C"}],"parameters_zh":[{"name":"","range":"200 °C 至 500 °C","cmc":"0,53 °C"}],"parameters_cs":[{"name":"","range":"200 °C až 500 °C","cmc":"0,53 °C"}],"technique":"Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","technique_en":"Comparison with a standard resistance sensor in a calibrating oven","technique_zh":"在校准炉中与标准电阻传感器比较","technique_cs":"Porovnání s etalonovým odporovým snímačem v kalibrační pícce","techniques":["Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard resistance sensor in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻传感器比较"],"techniques_cs":["Porovnání s etalonovým odporovým snímačem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 200 °C do 500 °C CMC 0,53 °C\nPorównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym","reference":"92/75-14-4","norm_bases":["92/75-14-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 200 °C do 500 °C CMC 0,53 °C Analogový a digitální teploměr Kalibrace – teplota Porovnání s etalonovým odporovým snímačem v kalibrační pícce 200 °C až 500 °C CMC 0,53 °C 92/75-14-4 Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem rezystancyjnym w piecu kalibracyjnym od 200 °C do 500 °C CMC 0,53 °C Analogovy a digitalni teplomer Kalibrace – teplota Porovnani s etalonovym odporovym snimacem v kalibracni picce 200 °C az 500 °C CMC 0,53 °C 92/75-14-4","search_en":"Analogue and digital thermometer Calibration – temperature Comparison with a standard resistance sensor in a calibrating oven 200 °C to 500 °C CMC 0,53 °C 92/75-14-4","search_zh":"模拟和数字温度计 校准 – 温度 在校准炉中与标准电阻传感器比较 200 °C 至 500 °C CMC 0,53 °C 92/75-14-4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"563b421d391fb9bc63db48c1","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Termometr analogowy i cyfrowy","test_object_en":"Analogue and digital thermometer","test_object_zh":"模拟和数字温度计","test_object_cs":"Analogový a digitální teploměr","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 500 °C do 1100 °C","cmc":"1,6 °C"}],"parameters_en":[{"name":"","range":"500 °C to 1100 °C","cmc":"1,6 °C"}],"parameters_zh":[{"name":"","range":"500 °C 至 1100 °C","cmc":"1,6 °C"}],"parameters_cs":[{"name":"","range":"500 °C až 1100 °C","cmc":"1,6 °C"}],"technique":"Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym","technique_en":"Comparison with a standard thermoelectric sensor in a horizontal furnace","technique_zh":"在卧式炉中与标准热电偶传感器比较","technique_cs":"Porovnání s etalonovým termoelektrickým snímačem v horizontální peci","techniques":["Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym"],"techniques_en":["Comparison with a standard thermoelectric sensor in a horizontal furnace"],"techniques_zh":["在卧式炉中与标准热电偶传感器比较"],"techniques_cs":["Porovnání s etalonovým termoelektrickým snímačem v horizontální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 500 °C do 1100 °C CMC 1,6 °C\nPorównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym","reference":"92/75-14-4","norm_bases":["92/75-14-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym od 500 °C do 1100 °C CMC 1,6 °C Analogový a digitální teploměr Kalibrace – teplota Porovnání s etalonovým termoelektrickým snímačem v horizontální peci 500 °C až 1100 °C CMC 1,6 °C 92/75-14-4 Termometr analogowy i cyfrowy Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem termoelektrycznym w piecu poziomym od 500 °C do 1100 °C CMC 1,6 °C Analogovy a digitalni teplomer Kalibrace – teplota Porovnani s etalonovym termoelektrickym snimacem v horizontalni peci 500 °C az 1100 °C CMC 1,6 °C 92/75-14-4","search_en":"Analogue and digital thermometer Calibration – temperature Comparison with a standard thermoelectric sensor in a horizontal furnace 500 °C to 1100 °C CMC 1,6 °C 92/75-14-4","search_zh":"模拟和数字温度计 校准 – 温度 在卧式炉中与标准热电偶传感器比较 500 °C 至 1100 °C CMC 1,6 °C 92/75-14-4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b41cd13c7b55f721fae8aea9","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"6","test_object":"Termometry bezpośrednio wskazujące i tory pomiarowe","test_object_en":"Direct indicating thermometers and measuring chains","test_object_zh":"直读式温度计和测量链","test_object_cs":"Přímoukazující teploměry a měřící řetězce","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od -30 °C do 200 °C","cmc":"0,30 °C"},{"name":"","range":"od 200 °C do 500 °C","cmc":"0,60 °C"}],"parameters_en":[{"name":"","range":"-30 °C to 200 °C","cmc":"0,30 °C"},{"name":"","range":"200 °C to 500 °C","cmc":"0,60 °C"}],"parameters_zh":[{"name":"","range":"-30 °C 至 200 °C","cmc":"0,30 °C"},{"name":"","range":"200 °C 至 500 °C","cmc":"0,60 °C"}],"parameters_cs":[{"name":"","range":"-30 °C až 200 °C","cmc":"0,30 °C"},{"name":"","range":"200 °C až 500 °C","cmc":"0,60 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym","technique_en":"Comparison with a standard resistance thermometer in a calibrating oven","technique_zh":"在校准炉中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kalibrační pícce","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym"],"techniques_en":["Comparison with a standard resistance thermometer in a calibrating oven"],"techniques_zh":["在校准炉中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kalibrační pícce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod -30 °C do 200 °C CMC 0,30 °C\nod 200 °C do 500 °C CMC 0,60 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym","reference":"92/75-14-5","norm_bases":["92/75-14-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące i tory pomiarowe Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym od -30 °C do 200 °C CMC 0,30 °C od 200 °C do 500 °C CMC 0,60 °C Přímoukazující teploměry a měřící řetězce Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kalibrační pícce -30 °C až 200 °C CMC 0,30 °C 200 °C až 500 °C CMC 0,60 °C 92/75-14-5 Termometry bezposrednio wskazujace i tory pomiarowe Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w piecu kalibracyjnym od -30 °C do 200 °C CMC 0,30 °C od 200 °C do 500 °C CMC 0,60 °C Primoukazujici teplomery a merici retezce Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kalibracni picce -30 °C az 200 °C CMC 0,30 °C 200 °C az 500 °C CMC 0,60 °C 92/75-14-5","search_en":"Direct indicating thermometers and measuring chains Calibration – temperature Comparison with a standard resistance thermometer in a calibrating oven -30 °C to 200 °C CMC 0,30 °C 200 °C to 500 °C CMC 0,60 °C 92/75-14-5","search_zh":"直读式温度计和测量链 校准 – 温度 在校准炉中与标准电阻温度计比较 -30 °C 至 200 °C CMC 0,30 °C 200 °C 至 500 °C CMC 0,60 °C 92/75-14-5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ff14335a8003e37961b2d34","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"6","test_object":"Termometry bezpośrednio wskazujące i tory pomiarowe","test_object_en":"Direct indicating thermometers and measuring chains","test_object_zh":"直读式温度计和测量链","test_object_cs":"Přímoukazující teploměry a měřící řetězce","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od 500 °C do 1100 °C","cmc":"1,7 °C"}],"parameters_en":[{"name":"","range":"500 °C to 1100 °C","cmc":"1,7 °C"}],"parameters_zh":[{"name":"","range":"500 °C 至 1100 °C","cmc":"1,7 °C"}],"parameters_cs":[{"name":"","range":"500 °C až 1100 °C","cmc":"1,7 °C"}],"technique":"Porównanie z wzorcowym czujnikiem termoelektrycznym","technique_en":"Comparison with a standard thermoelectric sensor","technique_zh":"与标准热电偶传感器比较","technique_cs":"Porovnání s etalonovým termoelektickým snímačem","techniques":["Porównanie z wzorcowym czujnikiem termoelektrycznym"],"techniques_en":["Comparison with a standard thermoelectric sensor"],"techniques_zh":["与标准热电偶传感器比较"],"techniques_cs":["Porovnání s etalonovým termoelektickým snímačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod 500 °C do 1100 °C CMC 1,7 °C\nPorównanie z wzorcowym czujnikiem termoelektrycznym","reference":"92/75-14-5","norm_bases":["92/75-14-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące i tory pomiarowe Wzorcowanie – temperatura Porównanie z wzorcowym czujnikiem termoelektrycznym od 500 °C do 1100 °C CMC 1,7 °C Přímoukazující teploměry a měřící řetězce Kalibrace – teplota Porovnání s etalonovým termoelektickým snímačem 500 °C až 1100 °C CMC 1,7 °C 92/75-14-5 Termometry bezposrednio wskazujace i tory pomiarowe Wzorcowanie – temperatura Porownanie z wzorcowym czujnikiem termoelektrycznym od 500 °C do 1100 °C CMC 1,7 °C Primoukazujici teplomery a merici retezce Kalibrace – teplota Porovnani s etalonovym termoelektickym snimacem 500 °C az 1100 °C CMC 1,7 °C 92/75-14-5","search_en":"Direct indicating thermometers and measuring chains Calibration – temperature Comparison with a standard thermoelectric sensor 500 °C to 1100 °C CMC 1,7 °C 92/75-14-5","search_zh":"直读式温度计和测量链 校准 – 温度 与标准热电偶传感器比较 500 °C 至 1100 °C CMC 1,7 °C 92/75-14-5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f3057ab6e6210e5bb9810943","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"7","test_object":"Przyrządy do pomiaru temperatury i kalibratory","test_object_en":"Temperature meters and calibrators","test_object_zh":"温度测量仪器和校准器","test_object_cs":"Teplotní měřidla a kalibrátory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"termopary R","range":"od -50 °C do 1760 °C","cmc":"2,1 °C"},{"name":"termopary S","range":"od -50 °C do 1760 °C","cmc":"2,1 °C"},{"name":"termopary B","range":"od 0 °C do 1820 °C","cmc":"1,8 °C"},{"name":"termopary J","range":"od -210 °C do 1200 °C","cmc":"0,7 °C"},{"name":"termopary T","range":"od -270 °C do 400 °C","cmc":"0,5 °C"},{"name":"termopary E","range":"od -270 °C do 1000 °C","cmc":"0,5 °C"},{"name":"termopary K","range":"od -270 °C do 1370 °C","cmc":"0,8 °C"},{"name":"termopary N","range":"od -270 °C do 1300 °C","cmc":"0,8 °C"}],"parameters_en":[{"name":"type R thermocouples","range":"-50 °C to 1760 °C","cmc":"2,1 °C"},{"name":"type S thermocouples","range":"-50 °C to 1760 °C","cmc":"2,1 °C"},{"name":"type B thermocouples","range":"0 °C to 1820 °C","cmc":"1,8 °C"},{"name":"type J thermocouples","range":"-210 °C to 1200 °C","cmc":"0,7 °C"},{"name":"type T thermocouples","range":"-270 °C to 400 °C","cmc":"0,5 °C"},{"name":"type E thermocouples","range":"-270 °C to 1000 °C","cmc":"0,5 °C"},{"name":"type K thermocouples","range":"-270 °C to 1370 °C","cmc":"0,8 °C"},{"name":"type N thermocouples","range":"-270 °C to 1300 °C","cmc":"0,8 °C"}],"parameters_zh":[{"name":"R 型热电偶","range":"-50 °C 至 1760 °C","cmc":"2,1 °C"},{"name":"S 型热电偶","range":"-50 °C 至 1760 °C","cmc":"2,1 °C"},{"name":"B 型热电偶","range":"0 °C 至 1820 °C","cmc":"1,8 °C"},{"name":"J 型热电偶","range":"-210 °C 至 1200 °C","cmc":"0,7 °C"},{"name":"T 型热电偶","range":"-270 °C 至 400 °C","cmc":"0,5 °C"},{"name":"E 型热电偶","range":"-270 °C 至 1000 °C","cmc":"0,5 °C"},{"name":"K 型热电偶","range":"-270 °C 至 1370 °C","cmc":"0,8 °C"},{"name":"N 型热电偶","range":"-270 °C 至 1300 °C","cmc":"0,8 °C"}],"parameters_cs":[{"name":"termočlánků R","range":"-50 °C až 1760 °C","cmc":"2,1 °C"},{"name":"termočlánků S","range":"-50 °C až 1760 °C","cmc":"2,1 °C"},{"name":"termočlánků B","range":"0 °C až 1820 °C","cmc":"1,8 °C"},{"name":"termočlánků J","range":"-210 °C až 1200 °C","cmc":"0,7 °C"},{"name":"termočlánků T","range":"-270 °C až 400 °C","cmc":"0,5 °C"},{"name":"termočlánků E","range":"-270 °C až 1000 °C","cmc":"0,5 °C"},{"name":"termočlánků K","range":"-270 °C až 1370 °C","cmc":"0,8 °C"},{"name":"termočlánků N","range":"-270 °C až 1300 °C","cmc":"0,8 °C"}],"technique":"Symulacja i pomiar napięcia stałego termoelektrycznych czujników temperatury","technique_en":"Simulation and measurement of DC voltage of thermoelectric temperature sensors","technique_zh":"热电偶温度传感器直流电压的模拟和测量","technique_cs":"Simulace a měření stejnosměrného napětí termoelektrických snímačů teploty","techniques":["Symulacja i pomiar napięcia stałego termoelektrycznych czujników temperatury"],"techniques_en":["Simulation and measurement of DC voltage of thermoelectric temperature sensors"],"techniques_zh":["热电偶温度传感器直流电压的模拟和测量"],"techniques_cs":["Simulace a měření stejnosměrného napětí termoelektrických snímačů teploty"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\ntermopary R od -50 °C do 1760 °C CMC 2,1 °C\ntermopary S od -50 °C do 1760 °C CMC 2,1 °C\ntermopary B od 0 °C do 1820 °C CMC 1,8 °C\ntermopary J od -210 °C do 1200 °C CMC 0,7 °C\ntermopary T od -270 °C do 400 °C CMC 0,5 °C\ntermopary E od -270 °C do 1000 °C CMC 0,5 °C\ntermopary K od -270 °C do 1370 °C CMC 0,8 °C\ntermopary N od -270 °C do 1300 °C CMC 0,8 °C\nSymulacja i pomiar napięcia stałego termoelektrycznych czujników temperatury","reference":"92/75-17-7","norm_bases":["92/75-17-7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru temperatury i kalibratory Wzorcowanie – temperatura Symulacja i pomiar napięcia stałego termoelektrycznych czujników temperatury termopary R od -50 °C do 1760 °C CMC 2,1 °C termopary S od -50 °C do 1760 °C CMC 2,1 °C termopary B od 0 °C do 1820 °C CMC 1,8 °C termopary J od -210 °C do 1200 °C CMC 0,7 °C termopary T od -270 °C do 400 °C CMC 0,5 °C termopary E od -270 °C do 1000 °C CMC 0,5 °C termopary K od -270 °C do 1370 °C CMC 0,8 °C termopary N od -270 °C do 1300 °C CMC 0,8 °C Teplotní měřidla a kalibrátory Kalibrace – teplota Simulace a měření stejnosměrného napětí termoelektrických snímačů teploty termočlánků R -50 °C až 1760 °C CMC 2,1 °C termočlánků S -50 °C až 1760 °C CMC 2,1 °C termočlánků B 0 °C až 1820 °C CMC 1,8 °C termočlánků J -210 °C až 1200 °C CMC 0,7 °C termočlánků T -270 °C až 400 °C CMC 0,5 °C termočlánků E -270 °C až 1000 °C CMC 0,5 °C termočlánků K -270 °C až 1370 °C CMC 0,8 °C termočlánků N -270 °C až 1300 °C CMC 0,8 °C 92/75-17-7 Przyrzady do pomiaru temperatury i kalibratory Wzorcowanie – temperatura Symulacja i pomiar napiecia stalego termoelektrycznych czujnikow temperatury termopary R od -50 °C do 1760 °C CMC 2,1 °C termopary S od -50 °C do 1760 °C CMC 2,1 °C termopary B od 0 °C do 1820 °C CMC 1,8 °C termopary J od -210 °C do 1200 °C CMC 0,7 °C termopary T od -270 °C do 400 °C CMC 0,5 °C termopary E od -270 °C do 1000 °C CMC 0,5 °C termopary K od -270 °C do 1370 °C CMC 0,8 °C termopary N od -270 °C do 1300 °C CMC 0,8 °C Teplotni meridla a kalibratory Kalibrace – teplota Simulace a mereni stejnosmerneho napeti termoelektrickych snimacu teploty termoclanku R -50 °C az 1760 °C CMC 2,1 °C termoclanku S -50 °C az 1760 °C CMC 2,1 °C termoclanku B 0 °C az 1820 °C CMC 1,8 °C termoclanku J -210 °C az 1200 °C CMC 0,7 °C termoclanku T -270 °C az 400 °C CMC 0,5 °C termoclanku E -270 °C az 1000 °C CMC 0,5 °C termoclanku K -270 °C az 1370 °C CMC 0,8 °C termoclanku N -270 °C az 1300 °C CMC 0,8 °C 92/75-17-7","search_en":"Temperature meters and calibrators Calibration – temperature Simulation and measurement of DC voltage of thermoelectric temperature sensors type R thermocouples -50 °C to 1760 °C CMC 2,1 °C type S thermocouples -50 °C to 1760 °C CMC 2,1 °C type B thermocouples 0 °C to 1820 °C CMC 1,8 °C type J thermocouples -210 °C to 1200 °C CMC 0,7 °C type T thermocouples -270 °C to 400 °C CMC 0,5 °C type E thermocouples -270 °C to 1000 °C CMC 0,5 °C type K thermocouples -270 °C to 1370 °C CMC 0,8 °C type N thermocouples -270 °C to 1300 °C CMC 0,8 °C 92/75-17-7","search_zh":"温度测量仪器和校准器 校准 – 温度 热电偶温度传感器直流电压的模拟和测量 R 型热电偶 -50 °C 至 1760 °C CMC 2,1 °C S 型热电偶 -50 °C 至 1760 °C CMC 2,1 °C B 型热电偶 0 °C 至 1820 °C CMC 1,8 °C J 型热电偶 -210 °C 至 1200 °C CMC 0,7 °C T 型热电偶 -270 °C 至 400 °C CMC 0,5 °C E 型热电偶 -270 °C 至 1000 °C CMC 0,5 °C K 型热电偶 -270 °C 至 1370 °C CMC 0,8 °C N 型热电偶 -270 °C 至 1300 °C CMC 0,8 °C 92/75-17-7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e08eb3f613909077ec9fc0e3","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"7","test_object":"Przyrządy do pomiaru temperatury i kalibratory","test_object_en":"Temperature meters and calibrators","test_object_zh":"温度测量仪器和校准器","test_object_cs":"Teplotní měřidla a kalibrátory","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"czujniki rezystancyjne Pt100","range":"od -200 °C do 850 °C","cmc":"0,4 °C"},{"name":"czujniki rezystancyjne Pt200","range":"od -200 °C do 850 °C","cmc":"0,3 °C"},{"name":"czujniki rezystancyjne Pt1000","range":"od -200 °C do 850 °C","cmc":"0,5 °C"},{"name":"czujniki rezystancyjne Ni100","range":"od -60 °C do 250 °C","cmc":"0,2 °C"}],"parameters_en":[{"name":"Pt100 resistance sensors","range":"-200 °C to 850 °C","cmc":"0,4 °C"},{"name":"Pt200 resistance sensors","range":"-200 °C to 850 °C","cmc":"0,3 °C"},{"name":"Pt1000 resistance sensors","range":"-200 °C to 850 °C","cmc":"0,5 °C"},{"name":"Ni100 resistance sensors","range":"-60 °C to 250 °C","cmc":"0,2 °C"}],"parameters_zh":[{"name":"Pt100 电阻传感器","range":"-200 °C 至 850 °C","cmc":"0,4 °C"},{"name":"Pt200 电阻传感器","range":"-200 °C 至 850 °C","cmc":"0,3 °C"},{"name":"Pt1000 电阻传感器","range":"-200 °C 至 850 °C","cmc":"0,5 °C"},{"name":"Ni100 电阻传感器","range":"-60 °C 至 250 °C","cmc":"0,2 °C"}],"parameters_cs":[{"name":"odporových snímačů Pt100","range":"-200 °C až 850 °C","cmc":"0,4 °C"},{"name":"odporových snímačů Pt200","range":"-200 °C až 850 °C","cmc":"0,3 °C"},{"name":"odporových snímačů Pt1000","range":"-200 °C až 850 °C","cmc":"0,5 °C"},{"name":"odporových snímačů Ni100","range":"-60 °C až 250 °C","cmc":"0,2 °C"}],"technique":"Symulacja i pomiar rezystancji rezystancyjnych czujników temperatury","technique_en":"Simulation and measurement of resistance of resistance temperature sensors","technique_zh":"电阻温度传感器电阻的模拟和测量","technique_cs":"Simulace a měření odporu odporových snímačů teploty","techniques":["Symulacja i pomiar rezystancji rezystancyjnych czujników temperatury"],"techniques_en":["Simulation and measurement of resistance of resistance temperature sensors"],"techniques_zh":["电阻温度传感器电阻的模拟和测量"],"techniques_cs":["Simulace a měření odporu odporových snímačů teploty"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nczujniki rezystancyjne Pt100 od -200 °C do 850 °C CMC 0,4 °C\nczujniki rezystancyjne Pt200 od -200 °C do 850 °C CMC 0,3 °C\nczujniki rezystancyjne Pt1000 od -200 °C do 850 °C CMC 0,5 °C\nczujniki rezystancyjne Ni100 od -60 °C do 250 °C CMC 0,2 °C\nSymulacja i pomiar rezystancji rezystancyjnych czujników temperatury","reference":"92/75-17-7","norm_bases":["92/75-17-7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru temperatury i kalibratory Wzorcowanie – temperatura Symulacja i pomiar rezystancji rezystancyjnych czujników temperatury czujniki rezystancyjne Pt100 od -200 °C do 850 °C CMC 0,4 °C czujniki rezystancyjne Pt200 od -200 °C do 850 °C CMC 0,3 °C czujniki rezystancyjne Pt1000 od -200 °C do 850 °C CMC 0,5 °C czujniki rezystancyjne Ni100 od -60 °C do 250 °C CMC 0,2 °C Teplotní měřidla a kalibrátory Kalibrace – teplota Simulace a měření odporu odporových snímačů teploty odporových snímačů Pt100 -200 °C až 850 °C CMC 0,4 °C odporových snímačů Pt200 -200 °C až 850 °C CMC 0,3 °C odporových snímačů Pt1000 -200 °C až 850 °C CMC 0,5 °C odporových snímačů Ni100 -60 °C až 250 °C CMC 0,2 °C 92/75-17-7 Przyrzady do pomiaru temperatury i kalibratory Wzorcowanie – temperatura Symulacja i pomiar rezystancji rezystancyjnych czujnikow temperatury czujniki rezystancyjne Pt100 od -200 °C do 850 °C CMC 0,4 °C czujniki rezystancyjne Pt200 od -200 °C do 850 °C CMC 0,3 °C czujniki rezystancyjne Pt1000 od -200 °C do 850 °C CMC 0,5 °C czujniki rezystancyjne Ni100 od -60 °C do 250 °C CMC 0,2 °C Teplotni meridla a kalibratory Kalibrace – teplota Simulace a mereni odporu odporovych snimacu teploty odporovych snimacu Pt100 -200 °C az 850 °C CMC 0,4 °C odporovych snimacu Pt200 -200 °C az 850 °C CMC 0,3 °C odporovych snimacu Pt1000 -200 °C az 850 °C CMC 0,5 °C odporovych snimacu Ni100 -60 °C az 250 °C CMC 0,2 °C 92/75-17-7","search_en":"Temperature meters and calibrators Calibration – temperature Simulation and measurement of resistance of resistance temperature sensors Pt100 resistance sensors -200 °C to 850 °C CMC 0,4 °C Pt200 resistance sensors -200 °C to 850 °C CMC 0,3 °C Pt1000 resistance sensors -200 °C to 850 °C CMC 0,5 °C Ni100 resistance sensors -60 °C to 250 °C CMC 0,2 °C 92/75-17-7","search_zh":"温度测量仪器和校准器 校准 – 温度 电阻温度传感器电阻的模拟和测量 Pt100 电阻传感器 -200 °C 至 850 °C CMC 0,4 °C Pt200 电阻传感器 -200 °C 至 850 °C CMC 0,3 °C Pt1000 电阻传感器 -200 °C 至 850 °C CMC 0,5 °C Ni100 电阻传感器 -60 °C 至 250 °C CMC 0,2 °C 92/75-17-7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d9c4dfdf511fcaaa856e5965","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Higrometry analogowe i cyfrowe, przetworniki wilgotności i tory pomiarowe wilgotności wraz z sondami wilgotności","test_object_en":"Analogue and digital hygrometers, humidity transducers and humidity measuring chains, including humidity probes","test_object_zh":"模拟和数字湿度计、湿度变送器及湿度测量链（含湿度探头）","test_object_cs":"Analogové a číslicové vlhkoměry, převodníky vlhkosti a měřící řetězce vlhkosti včetně vlhkostních sond","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"18 °C do 28 °C","range":"od 10 % RH do 90 % RH","cmc":"1,4 % RH"}],"parameters_en":[{"name":"18 °C to 28 °C","range":"10 % RH to 90 % RH","cmc":"1,4 % RH"}],"parameters_zh":[{"name":"18 °C 至 28 °C","range":"10 % RH 至 90 % RH","cmc":"1,4 % RH"}],"parameters_cs":[{"name":"18 °C až 28 °C","range":"10 % RH až 90 % RH","cmc":"1,4 % RH"}],"technique":"Porównanie z wzorcowym higrometrem pojemnościowym w komorze klimatyzacyjnej","technique_en":"Comparison with a reference capacitive hygrometer in an air-conditioning chamber","technique_zh":"在空调箱中与标准电容式湿度计比较","technique_cs":"Porovnání s etalonovým kapacitním vlhkoměrem v klimatizační komoře","techniques":["Porównanie z wzorcowym higrometrem pojemnościowym w komorze klimatyzacyjnej"],"techniques_en":["Comparison with a reference capacitive hygrometer in an air-conditioning chamber"],"techniques_zh":["在空调箱中与标准电容式湿度计比较"],"techniques_cs":["Porovnání s etalonovým kapacitním vlhkoměrem v klimatizační komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\n18 °C do 28 °C od 10 % RH do 90 % RH CMC 1,4 % RH\nPorównanie z wzorcowym higrometrem pojemnościowym w komorze klimatyzacyjnej","reference":"92/75-14-6","norm_bases":["92/75-14-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry analogowe i cyfrowe, przetworniki wilgotności i tory pomiarowe wilgotności wraz z sondami wilgotności Wzorcowanie – wilgotność powietrza Porównanie z wzorcowym higrometrem pojemnościowym w komorze klimatyzacyjnej 18 °C do 28 °C od 10 % RH do 90 % RH CMC 1,4 % RH Analogové a číslicové vlhkoměry, převodníky vlhkosti a měřící řetězce vlhkosti včetně vlhkostních sond Kalibrace – vlhkost vzduchu Porovnání s etalonovým kapacitním vlhkoměrem v klimatizační komoře 18 °C až 28 °C 10 % RH až 90 % RH CMC 1,4 % RH 92/75-14-6 Higrometry analogowe i cyfrowe, przetworniki wilgotnosci i tory pomiarowe wilgotnosci wraz z sondami wilgotnosci Wzorcowanie – wilgotnosc powietrza Porownanie z wzorcowym higrometrem pojemnosciowym w komorze klimatyzacyjnej 18 °C do 28 °C od 10 % RH do 90 % RH CMC 1,4 % RH Analogove a cislicove vlhkomery, prevodniky vlhkosti a merici retezce vlhkosti vcetne vlhkostnich sond Kalibrace – vlhkost vzduchu Porovnani s etalonovym kapacitnim vlhkomerem v klimatizacni komore 18 °C az 28 °C 10 % RH az 90 % RH CMC 1,4 % RH 92/75-14-6","search_en":"Analogue and digital hygrometers, humidity transducers and humidity measuring chains, including humidity probes Calibration – air humidity Comparison with a reference capacitive hygrometer in an air-conditioning chamber 18 °C to 28 °C 10 % RH to 90 % RH CMC 1,4 % RH 92/75-14-6","search_zh":"模拟和数字湿度计、湿度变送器及湿度测量链（含湿度探头） 校准 – 空气湿度 在空调箱中与标准电容式湿度计比较 18 °C 至 28 °C 10 % RH 至 90 % RH CMC 1,4 % RH 92/75-14-6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"70b60b39f79c0f9ebfb647b4","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / przyrządy do pomiaru i źródła napięcia stałego","test_object_en":"DC voltage / DC voltage meters and sources","test_object_zh":"直流电压 / 直流电压测量仪器和电压源","test_object_cs":"Stejnosměrné elektrické napětí / měřidla a zdroje stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 10 mV","cmc":"0,0050 % + 0,3 µV"},{"name":"","range":"od 10 mV do 200 mV","cmc":"0,0017 %"},{"name":"","range":"od 200 mV do 2 V","cmc":"0,0010 %"},{"name":"","range":"od 2 V do 20 V","cmc":"0,0009 %"},{"name":"","range":"od 20 V do 1000 V","cmc":"0,0014 %"}],"parameters_en":[{"name":"","range":"0 mV to 10 mV","cmc":"0,0050 % + 0,3 µV"},{"name":"","range":"10 mV to 200 mV","cmc":"0,0017 %"},{"name":"","range":"200 mV to 2 V","cmc":"0,0010 %"},{"name":"","range":"2 V to 20 V","cmc":"0,0009 %"},{"name":"","range":"20 V to 1000 V","cmc":"0,0014 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 10 mV","cmc":"0,0050 % + 0,3 µV"},{"name":"","range":"10 mV 至 200 mV","cmc":"0,0017 %"},{"name":"","range":"200 mV 至 2 V","cmc":"0,0010 %"},{"name":"","range":"2 V 至 20 V","cmc":"0,0009 %"},{"name":"","range":"20 V 至 1000 V","cmc":"0,0014 %"}],"parameters_cs":[{"name":"","range":"0 mV až 10 mV","cmc":"0,0050 % + 0,3 µV"},{"name":"","range":"10 mV až 200 mV","cmc":"0,0017 %"},{"name":"","range":"200 mV až 2 V","cmc":"0,0010 %"},{"name":"","range":"2 V až 20 V","cmc":"0,0009 %"},{"name":"","range":"20 V až 1000 V","cmc":"0,0014 %"}],"technique":"Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","technique_en":"Comparison or direct measurement with a standard multimeter","technique_zh":"与标准万用表比较或用其直接测量","technique_cs":"Porovnání nebo přímé měření pomocí etalonového multimetru","techniques":["Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego"],"techniques_en":["Comparison or direct measurement with a standard multimeter"],"techniques_zh":["与标准万用表比较或用其直接测量"],"techniques_cs":["Porovnání nebo přímé měření pomocí etalonového multimetru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 10 mV CMC 0,0050 % + 0,3 µV\nod 10 mV do 200 mV CMC 0,0017 %\nod 200 mV do 2 V CMC 0,0010 %\nod 2 V do 20 V CMC 0,0009 %\nod 20 V do 1000 V CMC 0,0014 %\nPorównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / przyrządy do pomiaru i źródła napięcia stałego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego od 0 mV do 10 mV CMC 0,0050 % + 0,3 µV od 10 mV do 200 mV CMC 0,0017 % od 200 mV do 2 V CMC 0,0010 % od 2 V do 20 V CMC 0,0009 % od 20 V do 1000 V CMC 0,0014 % Stejnosměrné elektrické napětí / měřidla a zdroje stejnosměrného napětí Kalibrace – elektrické veličiny Porovnání nebo přímé měření pomocí etalonového multimetru 0 mV až 10 mV CMC 0,0050 % + 0,3 µV 10 mV až 200 mV CMC 0,0017 % 200 mV až 2 V CMC 0,0010 % 2 V až 20 V CMC 0,0009 % 20 V až 1000 V CMC 0,0014 % 92/75-17-1, 92/75-17-6, 92/75-17-9 Napiecie stale / przyrzady do pomiaru i zrodla napiecia stalego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar bezposredni za pomoca multimetru wzorcowego od 0 mV do 10 mV CMC 0,0050 % + 0,3 µV od 10 mV do 200 mV CMC 0,0017 % od 200 mV do 2 V CMC 0,0010 % od 2 V do 20 V CMC 0,0009 % od 20 V do 1000 V CMC 0,0014 % Stejnosmerne elektricke napeti / meridla a zdroje stejnosmerneho napeti Kalibrace – elektricke veliciny Porovnani nebo prime mereni pomoci etalonoveho multimetru 0 mV az 10 mV CMC 0,0050 % + 0,3 µV 10 mV az 200 mV CMC 0,0017 % 200 mV az 2 V CMC 0,0010 % 2 V az 20 V CMC 0,0009 % 20 V az 1000 V CMC 0,0014 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"DC voltage / DC voltage meters and sources Calibration – electrical quantities Comparison or direct measurement with a standard multimeter 0 mV to 10 mV CMC 0,0050 % + 0,3 µV 10 mV to 200 mV CMC 0,0017 % 200 mV to 2 V CMC 0,0010 % 2 V to 20 V CMC 0,0009 % 20 V to 1000 V CMC 0,0014 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"直流电压 / 直流电压测量仪器和电压源 校准 – 电学量 与标准万用表比较或用其直接测量 0 mV 至 10 mV CMC 0,0050 % + 0,3 µV 10 mV 至 200 mV CMC 0,0017 % 200 mV 至 2 V CMC 0,0010 % 2 V 至 20 V CMC 0,0009 % 20 V 至 1000 V CMC 0,0014 % 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc2a6bb40786452cfddf4110","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / mierniki do badań instalacji elektrycznych","test_object_en":"DC voltage / inspection equipment","test_object_zh":"直流电压 / 电气安装检测仪","test_object_cs":"Stejnosměrné elektrické napětí / revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 kV do 5 kV","cmc":"0,48 %"}],"parameters_en":[{"name":"","range":"1 kV to 5 kV","cmc":"0,48 %"}],"parameters_zh":[{"name":"","range":"1 kV 至 5 kV","cmc":"0,48 %"}],"parameters_cs":[{"name":"","range":"1 kV až 5 kV","cmc":"0,48 %"}],"technique":"Pomiar kalibratorem mierników do badań instalacji elektrycznych","technique_en":"Measurement by a calibrator of inspection instruments","technique_zh":"用电气安装检测仪校准器测量","technique_cs":"Měření kalibrátorem revizních přístrojů","techniques":["Pomiar kalibratorem mierników do badań instalacji elektrycznych"],"techniques_en":["Measurement by a calibrator of inspection instruments"],"techniques_zh":["用电气安装检测仪校准器测量"],"techniques_cs":["Měření kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 kV do 5 kV CMC 0,48 %\nPomiar kalibratorem mierników do badań instalacji elektrycznych","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar kalibratorem mierników do badań instalacji elektrycznych od 1 kV do 5 kV CMC 0,48 % Stejnosměrné elektrické napětí / revizní přístroje Kalibrace – elektrické veličiny Měření kalibrátorem revizních přístrojů 1 kV až 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9 Napiecie stale / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar kalibratorem miernikow do badan instalacji elektrycznych od 1 kV do 5 kV CMC 0,48 % Stejnosmerne elektricke napeti / revizni pristroje Kalibrace – elektricke veliciny Mereni kalibratorem reviznich pristroju 1 kV az 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"DC voltage / inspection equipment Calibration – electrical quantities Measurement by a calibrator of inspection instruments 1 kV to 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"直流电压 / 电气安装检测仪 校准 – 电学量 用电气安装检测仪校准器测量 1 kV 至 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f0455a38fae934c9ed7d2097","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i źródła prądu stałego","test_object_en":"DC current / DC current meters and sources","test_object_zh":"直流电流 / 直流电流测量仪器和电流源","test_object_cs":"Stejnosměrný elektrický proud / měřidla a zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 µA do 10 µA","cmc":"0,015 %"},{"name":"","range":"od 10 µA do 200 µA","cmc":"0,012 %"},{"name":"","range":"od 200 µA do 20 mA","cmc":"0,0082 %"}],"parameters_en":[{"name":"","range":"1 µA to 10 µA","cmc":"0,015 %"},{"name":"","range":"10 µA to 200 µA","cmc":"0,012 %"},{"name":"","range":"200 µA to 20 mA","cmc":"0,0082 %"}],"parameters_zh":[{"name":"","range":"1 µA 至 10 µA","cmc":"0,015 %"},{"name":"","range":"10 µA 至 200 µA","cmc":"0,012 %"},{"name":"","range":"200 µA 至 20 mA","cmc":"0,0082 %"}],"parameters_cs":[{"name":"","range":"1 µA až 10 µA","cmc":"0,015 %"},{"name":"","range":"10 µA až 200 µA","cmc":"0,012 %"},{"name":"","range":"200 µA až 20 mA","cmc":"0,0082 %"}],"technique":"Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","technique_en":"Comparison or direct measurement with a standard multimeter","technique_zh":"与标准万用表比较或用其直接测量","technique_cs":"Porovnání nebo přímé měření pomocí etalonového multimetru","techniques":["Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego"],"techniques_en":["Comparison or direct measurement with a standard multimeter"],"techniques_zh":["与标准万用表比较或用其直接测量"],"techniques_cs":["Porovnání nebo přímé měření pomocí etalonového multimetru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 µA do 10 µA CMC 0,015 %\nod 10 µA do 200 µA CMC 0,012 %\nod 200 µA do 20 mA CMC 0,0082 %\nPorównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i źródła prądu stałego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego od 1 µA do 10 µA CMC 0,015 % od 10 µA do 200 µA CMC 0,012 % od 200 µA do 20 mA CMC 0,0082 % Stejnosměrný elektrický proud / měřidla a zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Porovnání nebo přímé měření pomocí etalonového multimetru 1 µA až 10 µA CMC 0,015 % 10 µA až 200 µA CMC 0,012 % 200 µA až 20 mA CMC 0,0082 % 92/75-17-1, 92/75-17-6, 92/75-17-9 Prad staly / przyrzady do pomiaru i zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar bezposredni za pomoca multimetru wzorcowego od 1 µA do 10 µA CMC 0,015 % od 10 µA do 200 µA CMC 0,012 % od 200 µA do 20 mA CMC 0,0082 % Stejnosmerny elektricky proud / meridla a zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Porovnani nebo prime mereni pomoci etalonoveho multimetru 1 µA az 10 µA CMC 0,015 % 10 µA az 200 µA CMC 0,012 % 200 µA az 20 mA CMC 0,0082 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"DC current / DC current meters and sources Calibration – electrical quantities Comparison or direct measurement with a standard multimeter 1 µA to 10 µA CMC 0,015 % 10 µA to 200 µA CMC 0,012 % 200 µA to 20 mA CMC 0,0082 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"直流电流 / 直流电流测量仪器和电流源 校准 – 电学量 与标准万用表比较或用其直接测量 1 µA 至 10 µA CMC 0,015 % 10 µA 至 200 µA CMC 0,012 % 200 µA 至 20 mA CMC 0,0082 % 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f99f787a4fd24a46b31a8d5","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i źródła prądu stałego","test_object_en":"DC current / DC current meters and sources","test_object_zh":"直流电流 / 直流电流测量仪器和电流源","test_object_cs":"Stejnosměrný elektrický proud / měřidla a zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 20 mA do 10 A","cmc":"0,0062 %"},{"name":"","range":"od 10 A do 100 A","cmc":"0,013 %"},{"name":"","range":"od 100 A do 1000 A","cmc":"2,4 %"}],"parameters_en":[{"name":"","range":"20 mA to 10 A","cmc":"0,0062 %"},{"name":"","range":"10 A to 100 A","cmc":"0,013 %"},{"name":"","range":"100 A to 1000 A","cmc":"2,4 %"}],"parameters_zh":[{"name":"","range":"20 mA 至 10 A","cmc":"0,0062 %"},{"name":"","range":"10 A 至 100 A","cmc":"0,013 %"},{"name":"","range":"100 A 至 1000 A","cmc":"2,4 %"}],"parameters_cs":[{"name":"","range":"20 mA až 10 A","cmc":"0,0062 %"},{"name":"","range":"10 A až 100 A","cmc":"0,013 %"},{"name":"","range":"100 A až 1000 A","cmc":"2,4 %"}],"technique":"Porównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym","technique_en":"Comparison or measurement with a standard multimeter with a current shunt","technique_zh":"用带电流分流器的标准万用表比较或测量","technique_cs":"Porovnání nebo měření pomocí etalonového multimetru s proudovým bočníkem","techniques":["Porównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym"],"techniques_en":["Comparison or measurement with a standard multimeter with a current shunt"],"techniques_zh":["用带电流分流器的标准万用表比较或测量"],"techniques_cs":["Porovnání nebo měření pomocí etalonového multimetru s proudovým bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 20 mA do 10 A CMC 0,0062 %\nod 10 A do 100 A CMC 0,013 %\nod 100 A do 1000 A CMC 2,4 %\nPorównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i źródła prądu stałego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym od 20 mA do 10 A CMC 0,0062 % od 10 A do 100 A CMC 0,013 % od 100 A do 1000 A CMC 2,4 % Stejnosměrný elektrický proud / měřidla a zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Porovnání nebo měření pomocí etalonového multimetru s proudovým bočníkem 20 mA až 10 A CMC 0,0062 % 10 A až 100 A CMC 0,013 % 100 A až 1000 A CMC 2,4 % 92/75-17-1, 92/75-17-6, 92/75-17-9 Prad staly / przyrzady do pomiaru i zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar za pomoca multimetru wzorcowego z bocznikiem pradowym od 20 mA do 10 A CMC 0,0062 % od 10 A do 100 A CMC 0,013 % od 100 A do 1000 A CMC 2,4 % Stejnosmerny elektricky proud / meridla a zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Porovnani nebo mereni pomoci etalonoveho multimetru s proudovym bocnikem 20 mA az 10 A CMC 0,0062 % 10 A az 100 A CMC 0,013 % 100 A az 1000 A CMC 2,4 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"DC current / DC current meters and sources Calibration – electrical quantities Comparison or measurement with a standard multimeter with a current shunt 20 mA to 10 A CMC 0,0062 % 10 A to 100 A CMC 0,013 % 100 A to 1000 A CMC 2,4 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"直流电流 / 直流电流测量仪器和电流源 校准 – 电学量 用带电流分流器的标准万用表比较或测量 20 mA 至 10 A CMC 0,0062 % 10 A 至 100 A CMC 0,013 % 100 A 至 1000 A CMC 2,4 % 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e59c225ae839cf6530d14b40","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / mierniki cęgowe","test_object_en":"DC current / clamp testers","test_object_zh":"直流电流 / 钳形仪表","test_object_cs":"Stejnosměrný elektrický proud / klešťové přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 mA do 1000 A","cmc":"0,35 %"}],"parameters_en":[{"name":"","range":"1 mA to 1000 A","cmc":"0,35 %"}],"parameters_zh":[{"name":"","range":"1 mA 至 1000 A","cmc":"0,35 %"}],"parameters_cs":[{"name":"","range":"1 mA až 1000 A","cmc":"0,35 %"}],"technique":"Pomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową","technique_en":"Measurement of current simulated by a standard calibrator with current coil","technique_zh":"测量由带电流线圈的标准校准器模拟的电流","technique_cs":"Měření proudu simulovaného etalonovým kalibrátorem s proudovou cívkou","techniques":["Pomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową"],"techniques_en":["Measurement of current simulated by a standard calibrator with current coil"],"techniques_zh":["测量由带电流线圈的标准校准器模拟的电流"],"techniques_cs":["Měření proudu simulovaného etalonovým kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 1 mA do 1000 A CMC 0,35 %\nPomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / mierniki cęgowe Wzorcowanie – wielkości elektryczne Pomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową od 1 mA do 1000 A CMC 0,35 % Stejnosměrný elektrický proud / klešťové přístroje Kalibrace – elektrické veličiny Měření proudu simulovaného etalonovým kalibrátorem s proudovou cívkou 1 mA až 1000 A CMC 0,35 % 92/75-17-1, 92/75-17-6, 92/75-17-9 Prad staly / mierniki cegowe Wzorcowanie – wielkosci elektryczne Pomiar pradu symulowanego kalibratorem wzorcowym z cewka pradowa od 1 mA do 1000 A CMC 0,35 % Stejnosmerny elektricky proud / klestove pristroje Kalibrace – elektricke veliciny Mereni proudu simulovaneho etalonovym kalibratorem s proudovou civkou 1 mA az 1000 A CMC 0,35 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"DC current / clamp testers Calibration – electrical quantities Measurement of current simulated by a standard calibrator with current coil 1 mA to 1000 A CMC 0,35 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"直流电流 / 钳形仪表 校准 – 电学量 测量由带电流线圈的标准校准器模拟的电流 1 mA 至 1000 A CMC 0,35 % 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cfd4cb57b7f144aec7b48543","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / przyrządy do pomiaru i źródła napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters and sources","test_object_zh":"交流电压 / 交流电压测量仪器和电压源","test_object_cs":"Střídavé elektrické napětí / měřidla a zdroje střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 100 Hz","range":"od 10 mV do 200 mV","cmc":"0,020 % + 15 µV"},{"name":"100 Hz do 2 kHz","range":"od 10 mV do 200 mV","cmc":"0,015 % + 14 µV"},{"name":"2 kHz do 10 kHz","range":"od 10 mV do 200 mV","cmc":"0,022 % + 15 µV"},{"name":"10 kHz do 30 kHz","range":"od 10 mV do 200 mV","cmc":"0,040 % + 15 µV"},{"name":"30 kHz do 100 kHz","range":"od 10 mV do 200 mV","cmc":"0,089 % + 15 µV"},{"name":"40 Hz do 100 Hz","range":"od 200 mV do 2 V","cmc":"0,013 % + 32 µV"},{"name":"100 Hz do 2 kHz","range":"od 200 mV do 2 V","cmc":"0,012 % + 32 µV"},{"name":"2 kHz do 10 kHz","range":"od 200 mV do 2 V","cmc":"0,013 % + 32 µV"},{"name":"10 kHz do 30 kHz","range":"od 200 mV do 2 V","cmc":"0,025 % + 52 µV"},{"name":"30 kHz do 100 kHz","range":"od 200 mV do 2 V","cmc":"0,059 % + 0,24 mV"},{"name":"40 Hz do 100 Hz","range":"od 2 V do 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"100 Hz do 2 kHz","range":"od 2 V do 20 V","cmc":"0,012 % + 0,32 mV"},{"name":"2 kHz do 10 kHz","range":"od 2 V do 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"10 kHz do 30 kHz","range":"od 2 V do 20 V","cmc":"0,025 % + 0,52 mV"},{"name":"30 kHz do 100 kHz","range":"od 2 V do 20 V","cmc":"0,059 % + 2,4 mV"},{"name":"40 Hz do 100 Hz","range":"od 20 V do 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"100 Hz do 2 kHz","range":"od 20 V do 200 V","cmc":"0,012 % + 3,2 mV"},{"name":"2 kHz do 10 kHz","range":"od 20 V do 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"10 kHz do 30 kHz","range":"od 20 V do 200 V","cmc":"0,026 % + 5,2 mV"},{"name":"30 kHz do 100 kHz","range":"od 20 V do 200 V","cmc":"0,059 % + 24 mV"},{"name":"40 Hz do 10 kHz","range":"od 200 V do 1000 V","cmc":"0,015 % + 26 mV"},{"name":"10 kHz do 30 kHz","range":"od 200 V do 1000 V","cmc":"0,031 % + 58 mV"}],"parameters_en":[{"name":"40 Hz to 100 Hz","range":"10 mV to 200 mV","cmc":"0,020 % + 15 µV"},{"name":"100 Hz to 2 kHz","range":"10 mV to 200 mV","cmc":"0,015 % + 14 µV"},{"name":"2 kHz to 10 kHz","range":"10 mV to 200 mV","cmc":"0,022 % + 15 µV"},{"name":"10 kHz to 30 kHz","range":"10 mV to 200 mV","cmc":"0,040 % + 15 µV"},{"name":"30 kHz to 100 kHz","range":"10 mV to 200 mV","cmc":"0,089 % + 15 µV"},{"name":"40 Hz to 100 Hz","range":"200 mV to 2 V","cmc":"0,013 % + 32 µV"},{"name":"100 Hz to 2 kHz","range":"200 mV to 2 V","cmc":"0,012 % + 32 µV"},{"name":"2 kHz to 10 kHz","range":"200 mV to 2 V","cmc":"0,013 % + 32 µV"},{"name":"10 kHz to 30 kHz","range":"200 mV to 2 V","cmc":"0,025 % + 52 µV"},{"name":"30 kHz to 100 kHz","range":"200 mV to 2 V","cmc":"0,059 % + 0,24 mV"},{"name":"40 Hz to 100 Hz","range":"2 V to 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"100 Hz to 2 kHz","range":"2 V to 20 V","cmc":"0,012 % + 0,32 mV"},{"name":"2 kHz to 10 kHz","range":"2 V to 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"10 kHz to 30 kHz","range":"2 V to 20 V","cmc":"0,025 % + 0,52 mV"},{"name":"30 kHz to 100 kHz","range":"2 V to 20 V","cmc":"0,059 % + 2,4 mV"},{"name":"40 Hz to 100 Hz","range":"20 V to 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"100 Hz to 2 kHz","range":"20 V to 200 V","cmc":"0,012 % + 3,2 mV"},{"name":"2 kHz to 10 kHz","range":"20 V to 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"10 kHz to 30 kHz","range":"20 V to 200 V","cmc":"0,026 % + 5,2 mV"},{"name":"30 kHz to 100 kHz","range":"20 V to 200 V","cmc":"0,059 % + 24 mV"},{"name":"40 Hz to 10 kHz","range":"200 V to 1000 V","cmc":"0,015 % + 26 mV"},{"name":"10 kHz to 30 kHz","range":"200 V to 1000 V","cmc":"0,031 % + 58 mV"}],"parameters_zh":[{"name":"40 Hz 至 100 Hz","range":"10 mV 至 200 mV","cmc":"0,020 % + 15 µV"},{"name":"100 Hz 至 2 kHz","range":"10 mV 至 200 mV","cmc":"0,015 % + 14 µV"},{"name":"2 kHz 至 10 kHz","range":"10 mV 至 200 mV","cmc":"0,022 % + 15 µV"},{"name":"10 kHz 至 30 kHz","range":"10 mV 至 200 mV","cmc":"0,040 % + 15 µV"},{"name":"30 kHz 至 100 kHz","range":"10 mV 至 200 mV","cmc":"0,089 % + 15 µV"},{"name":"40 Hz 至 100 Hz","range":"200 mV 至 2 V","cmc":"0,013 % + 32 µV"},{"name":"100 Hz 至 2 kHz","range":"200 mV 至 2 V","cmc":"0,012 % + 32 µV"},{"name":"2 kHz 至 10 kHz","range":"200 mV 至 2 V","cmc":"0,013 % + 32 µV"},{"name":"10 kHz 至 30 kHz","range":"200 mV 至 2 V","cmc":"0,025 % + 52 µV"},{"name":"30 kHz 至 100 kHz","range":"200 mV 至 2 V","cmc":"0,059 % + 0,24 mV"},{"name":"40 Hz 至 100 Hz","range":"2 V 至 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"100 Hz 至 2 kHz","range":"2 V 至 20 V","cmc":"0,012 % + 0,32 mV"},{"name":"2 kHz 至 10 kHz","range":"2 V 至 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"10 kHz 至 30 kHz","range":"2 V 至 20 V","cmc":"0,025 % + 0,52 mV"},{"name":"30 kHz 至 100 kHz","range":"2 V 至 20 V","cmc":"0,059 % + 2,4 mV"},{"name":"40 Hz 至 100 Hz","range":"20 V 至 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"100 Hz 至 2 kHz","range":"20 V 至 200 V","cmc":"0,012 % + 3,2 mV"},{"name":"2 kHz 至 10 kHz","range":"20 V 至 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"10 kHz 至 30 kHz","range":"20 V 至 200 V","cmc":"0,026 % + 5,2 mV"},{"name":"30 kHz 至 100 kHz","range":"20 V 至 200 V","cmc":"0,059 % + 24 mV"},{"name":"40 Hz 至 10 kHz","range":"200 V 至 1000 V","cmc":"0,015 % + 26 mV"},{"name":"10 kHz 至 30 kHz","range":"200 V 至 1000 V","cmc":"0,031 % + 58 mV"}],"parameters_cs":[{"name":"40 Hz až 100 Hz","range":"10 mV až 200 mV","cmc":"0,020 % + 15 µV"},{"name":"100 Hz až 2 kHz","range":"10 mV až 200 mV","cmc":"0,015 % + 14 µV"},{"name":"2 kHz až 10 kHz","range":"10 mV až 200 mV","cmc":"0,022 % + 15 µV"},{"name":"10 kHz až 30 kHz","range":"10 mV až 200 mV","cmc":"0,040 % + 15 µV"},{"name":"30 kHz až 100 kHz","range":"10 mV až 200 mV","cmc":"0,089 % + 15 µV"},{"name":"40 Hz až 100 Hz","range":"200 mV až 2 V","cmc":"0,013 % + 32 µV"},{"name":"100 Hz až 2 kHz","range":"200 mV až 2 V","cmc":"0,012 % + 32 µV"},{"name":"2 kHz až 10 kHz","range":"200 mV až 2 V","cmc":"0,013 % + 32 µV"},{"name":"10 kHz až 30 kHz","range":"200 mV až 2 V","cmc":"0,025 % + 52 µV"},{"name":"30 kHz až 100 kHz","range":"200 mV až 2 V","cmc":"0,059 % + 0,24 mV"},{"name":"40 Hz až 100 Hz","range":"2 V až 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"100 Hz až 2 kHz","range":"2 V až 20 V","cmc":"0,012 % + 0,32 mV"},{"name":"2 kHz až 10 kHz","range":"2 V až 20 V","cmc":"0,013 % + 0,32 mV"},{"name":"10 kHz až 30 kHz","range":"2 V až 20 V","cmc":"0,025 % + 0,52 mV"},{"name":"30 kHz až 100 kHz","range":"2 V až 20 V","cmc":"0,059 % + 2,4 mV"},{"name":"40 Hz až 100 Hz","range":"20 V až 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"100 Hz až 2 kHz","range":"20 V až 200 V","cmc":"0,012 % + 3,2 mV"},{"name":"2 kHz až 10 kHz","range":"20 V až 200 V","cmc":"0,014 % + 3,2 mV"},{"name":"10 kHz až 30 kHz","range":"20 V až 200 V","cmc":"0,026 % + 5,2 mV"},{"name":"30 kHz až 100 kHz","range":"20 V až 200 V","cmc":"0,059 % + 24 mV"},{"name":"40 Hz až 10 kHz","range":"200 V až 1000 V","cmc":"0,015 % + 26 mV"},{"name":"10 kHz až 30 kHz","range":"200 V až 1000 V","cmc":"0,031 % + 58 mV"}],"technique":"Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","technique_en":"Comparison or direct measurement with a standard multimeter","technique_zh":"与标准万用表比较或用其直接测量","technique_cs":"Porovnání nebo přímé měření pomocí etalonového multimetru","techniques":["Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego"],"techniques_en":["Comparison or direct measurement with a standard multimeter"],"techniques_zh":["与标准万用表比较或用其直接测量"],"techniques_cs":["Porovnání nebo přímé měření pomocí etalonového multimetru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 100 Hz od 10 mV do 200 mV CMC 0,020 % + 15 µV\n100 Hz do 2 kHz od 10 mV do 200 mV CMC 0,015 % + 14 µV\n2 kHz do 10 kHz od 10 mV do 200 mV CMC 0,022 % + 15 µV\n10 kHz do 30 kHz od 10 mV do 200 mV CMC 0,040 % + 15 µV\n30 kHz do 100 kHz od 10 mV do 200 mV CMC 0,089 % + 15 µV\n40 Hz do 100 Hz od 200 mV do 2 V CMC 0,013 % + 32 µV\n100 Hz do 2 kHz od 200 mV do 2 V CMC 0,012 % + 32 µV\n2 kHz do 10 kHz od 200 mV do 2 V CMC 0,013 % + 32 µV\n10 kHz do 30 kHz od 200 mV do 2 V CMC 0,025 % + 52 µV\n30 kHz do 100 kHz od 200 mV do 2 V CMC 0,059 % + 0,24 mV\n40 Hz do 100 Hz od 2 V do 20 V CMC 0,013 % + 0,32 mV\n100 Hz do 2 kHz od 2 V do 20 V CMC 0,012 % + 0,32 mV\n2 kHz do 10 kHz od 2 V do 20 V CMC 0,013 % + 0,32 mV\n10 kHz do 30 kHz od 2 V do 20 V CMC 0,025 % + 0,52 mV\n30 kHz do 100 kHz od 2 V do 20 V CMC 0,059 % + 2,4 mV\n40 Hz do 100 Hz od 20 V do 200 V CMC 0,014 % + 3,2 mV\n100 Hz do 2 kHz od 20 V do 200 V CMC 0,012 % + 3,2 mV\n2 kHz do 10 kHz od 20 V do 200 V CMC 0,014 % + 3,2 mV\n10 kHz do 30 kHz od 20 V do 200 V CMC 0,026 % + 5,2 mV\n30 kHz do 100 kHz od 20 V do 200 V CMC 0,059 % + 24 mV\n40 Hz do 10 kHz od 200 V do 1000 V CMC 0,015 % + 26 mV\n10 kHz do 30 kHz od 200 V do 1000 V CMC 0,031 % + 58 mV\nPorównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / przyrządy do pomiaru i źródła napięcia przemiennego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego 40 Hz do 100 Hz od 10 mV do 200 mV CMC 0,020 % + 15 µV 100 Hz do 2 kHz od 10 mV do 200 mV CMC 0,015 % + 14 µV 2 kHz do 10 kHz od 10 mV do 200 mV CMC 0,022 % + 15 µV 10 kHz do 30 kHz od 10 mV do 200 mV CMC 0,040 % + 15 µV 30 kHz do 100 kHz od 10 mV do 200 mV CMC 0,089 % + 15 µV 40 Hz do 100 Hz od 200 mV do 2 V CMC 0,013 % + 32 µV 100 Hz do 2 kHz od 200 mV do 2 V CMC 0,012 % + 32 µV 2 kHz do 10 kHz od 200 mV do 2 V CMC 0,013 % + 32 µV 10 kHz do 30 kHz od 200 mV do 2 V CMC 0,025 % + 52 µV 30 kHz do 100 kHz od 200 mV do 2 V CMC 0,059 % + 0,24 mV 40 Hz do 100 Hz od 2 V do 20 V CMC 0,013 % + 0,32 mV 100 Hz do 2 kHz od 2 V do 20 V CMC 0,012 % + 0,32 mV 2 kHz do 10 kHz od 2 V do 20 V CMC 0,013 % + 0,32 mV 10 kHz do 30 kHz od 2 V do 20 V CMC 0,025 % + 0,52 mV 30 kHz do 100 kHz od 2 V do 20 V CMC 0,059 % + 2,4 mV 40 Hz do 100 Hz od 20 V do 200 V CMC 0,014 % + 3,2 mV 100 Hz do 2 kHz od 20 V do 200 V CMC 0,012 % + 3,2 mV 2 kHz do 10 kHz od 20 V do 200 V CMC 0,014 % + 3,2 mV 10 kHz do 30 kHz od 20 V do 200 V CMC 0,026 % + 5,2 mV 30 kHz do 100 kHz od 20 V do 200 V CMC 0,059 % + 24 mV 40 Hz do 10 kHz od 200 V do 1000 V CMC 0,015 % + 26 mV 10 kHz do 30 kHz od 200 V do 1000 V CMC 0,031 % + 58 mV Střídavé elektrické napětí / měřidla a zdroje střídavého napětí Kalibrace – elektrické veličiny Porovnání nebo přímé měření pomocí etalonového multimetru 40 Hz až 100 Hz 10 mV až 200 mV CMC 0,020 % + 15 µV 100 Hz až 2 kHz 10 mV až 200 mV CMC 0,015 % + 14 µV 2 kHz až 10 kHz 10 mV až 200 mV CMC 0,022 % + 15 µV 10 kHz až 30 kHz 10 mV až 200 mV CMC 0,040 % + 15 µV 30 kHz až 100 kHz 10 mV až 200 mV CMC 0,089 % + 15 µV 40 Hz až 100 Hz 200 mV až 2 V CMC 0,013 % + 32 µV 100 Hz až 2 kHz 200 mV až 2 V CMC 0,012 % + 32 µV 2 kHz až 10 kHz 200 mV až 2 V CMC 0,013 % + 32 µV 10 kHz až 30 kHz 200 mV až 2 V CMC 0,025 % + 52 µV 30 kHz až 100 kHz 200 mV až 2 V CMC 0,059 % + 0,24 mV 40 Hz až 100 Hz 2 V až 20 V CMC 0,013 % + 0,32 mV 100 Hz až 2 kHz 2 V až 20 V CMC 0,012 % + 0,32 mV 2 kHz až 10 kHz 2 V až 20 V CMC 0,013 % + 0,32 mV 10 kHz až 30 kHz 2 V až 20 V CMC 0,025 % + 0,52 mV 30 kHz až 100 kHz 2 V až 20 V CMC 0,059 % + 2,4 mV 40 Hz až 100 Hz 20 V až 200 V CMC 0,014 % + 3,2 mV 100 Hz až 2 kHz 20 V až 200 V CMC 0,012 % + 3,2 mV 2 kHz až 10 kHz 20 V až 200 V CMC 0,014 % + 3,2 mV 10 kHz až 30 kHz 20 V až 200 V CMC 0,026 % + 5,2 mV 30 kHz až 100 kHz 20 V až 200 V CMC 0,059 % + 24 mV 40 Hz až 10 kHz 200 V až 1000 V CMC 0,015 % + 26 mV 10 kHz až 30 kHz 200 V až 1000 V CMC 0,031 % + 58 mV 92/75-17-1, 92/75-17-6, 92/75-17-9 Napiecie przemienne / przyrzady do pomiaru i zrodla napiecia przemiennego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar bezposredni za pomoca multimetru wzorcowego 40 Hz do 100 Hz od 10 mV do 200 mV CMC 0,020 % + 15 µV 100 Hz do 2 kHz od 10 mV do 200 mV CMC 0,015 % + 14 µV 2 kHz do 10 kHz od 10 mV do 200 mV CMC 0,022 % + 15 µV 10 kHz do 30 kHz od 10 mV do 200 mV CMC 0,040 % + 15 µV 30 kHz do 100 kHz od 10 mV do 200 mV CMC 0,089 % + 15 µV 40 Hz do 100 Hz od 200 mV do 2 V CMC 0,013 % + 32 µV 100 Hz do 2 kHz od 200 mV do 2 V CMC 0,012 % + 32 µV 2 kHz do 10 kHz od 200 mV do 2 V CMC 0,013 % + 32 µV 10 kHz do 30 kHz od 200 mV do 2 V CMC 0,025 % + 52 µV 30 kHz do 100 kHz od 200 mV do 2 V CMC 0,059 % + 0,24 mV 40 Hz do 100 Hz od 2 V do 20 V CMC 0,013 % + 0,32 mV 100 Hz do 2 kHz od 2 V do 20 V CMC 0,012 % + 0,32 mV 2 kHz do 10 kHz od 2 V do 20 V CMC 0,013 % + 0,32 mV 10 kHz do 30 kHz od 2 V do 20 V CMC 0,025 % + 0,52 mV 30 kHz do 100 kHz od 2 V do 20 V CMC 0,059 % + 2,4 mV 40 Hz do 100 Hz od 20 V do 200 V CMC 0,014 % + 3,2 mV 100 Hz do 2 kHz od 20 V do 200 V CMC 0,012 % + 3,2 mV 2 kHz do 10 kHz od 20 V do 200 V CMC 0,014 % + 3,2 mV 10 kHz do 30 kHz od 20 V do 200 V CMC 0,026 % + 5,2 mV 30 kHz do 100 kHz od 20 V do 200 V CMC 0,059 % + 24 mV 40 Hz do 10 kHz od 200 V do 1000 V CMC 0,015 % + 26 mV 10 kHz do 30 kHz od 200 V do 1000 V CMC 0,031 % + 58 mV Stridave elektricke napeti / meridla a zdroje stridaveho napeti Kalibrace – elektricke veliciny Porovnani nebo prime mereni pomoci etalonoveho multimetru 40 Hz az 100 Hz 10 mV az 200 mV CMC 0,020 % + 15 µV 100 Hz az 2 kHz 10 mV az 200 mV CMC 0,015 % + 14 µV 2 kHz az 10 kHz 10 mV az 200 mV CMC 0,022 % + 15 µV 10 kHz az 30 kHz 10 mV az 200 mV CMC 0,040 % + 15 µV 30 kHz az 100 kHz 10 mV az 200 mV CMC 0,089 % + 15 µV 40 Hz az 100 Hz 200 mV az 2 V CMC 0,013 % + 32 µV 100 Hz az 2 kHz 200 mV az 2 V CMC 0,012 % + 32 µV 2 kHz az 10 kHz 200 mV az 2 V CMC 0,013 % + 32 µV 10 kHz az 30 kHz 200 mV az 2 V CMC 0,025 % + 52 µV 30 kHz az 100 kHz 200 mV az 2 V CMC 0,059 % + 0,24 mV 40 Hz az 100 Hz 2 V az 20 V CMC 0,013 % + 0,32 mV 100 Hz az 2 kHz 2 V az 20 V CMC 0,012 % + 0,32 mV 2 kHz az 10 kHz 2 V az 20 V CMC 0,013 % + 0,32 mV 10 kHz az 30 kHz 2 V az 20 V CMC 0,025 % + 0,52 mV 30 kHz az 100 kHz 2 V az 20 V CMC 0,059 % + 2,4 mV 40 Hz az 100 Hz 20 V az 200 V CMC 0,014 % + 3,2 mV 100 Hz az 2 kHz 20 V az 200 V CMC 0,012 % + 3,2 mV 2 kHz az 10 kHz 20 V az 200 V CMC 0,014 % + 3,2 mV 10 kHz az 30 kHz 20 V az 200 V CMC 0,026 % + 5,2 mV 30 kHz az 100 kHz 20 V az 200 V CMC 0,059 % + 24 mV 40 Hz az 10 kHz 200 V az 1000 V CMC 0,015 % + 26 mV 10 kHz az 30 kHz 200 V az 1000 V CMC 0,031 % + 58 mV 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"AC voltage / AC voltage meters and sources Calibration – electrical quantities Comparison or direct measurement with a standard multimeter 40 Hz to 100 Hz 10 mV to 200 mV CMC 0,020 % + 15 µV 100 Hz to 2 kHz 10 mV to 200 mV CMC 0,015 % + 14 µV 2 kHz to 10 kHz 10 mV to 200 mV CMC 0,022 % + 15 µV 10 kHz to 30 kHz 10 mV to 200 mV CMC 0,040 % + 15 µV 30 kHz to 100 kHz 10 mV to 200 mV CMC 0,089 % + 15 µV 40 Hz to 100 Hz 200 mV to 2 V CMC 0,013 % + 32 µV 100 Hz to 2 kHz 200 mV to 2 V CMC 0,012 % + 32 µV 2 kHz to 10 kHz 200 mV to 2 V CMC 0,013 % + 32 µV 10 kHz to 30 kHz 200 mV to 2 V CMC 0,025 % + 52 µV 30 kHz to 100 kHz 200 mV to 2 V CMC 0,059 % + 0,24 mV 40 Hz to 100 Hz 2 V to 20 V CMC 0,013 % + 0,32 mV 100 Hz to 2 kHz 2 V to 20 V CMC 0,012 % + 0,32 mV 2 kHz to 10 kHz 2 V to 20 V CMC 0,013 % + 0,32 mV 10 kHz to 30 kHz 2 V to 20 V CMC 0,025 % + 0,52 mV 30 kHz to 100 kHz 2 V to 20 V CMC 0,059 % + 2,4 mV 40 Hz to 100 Hz 20 V to 200 V CMC 0,014 % + 3,2 mV 100 Hz to 2 kHz 20 V to 200 V CMC 0,012 % + 3,2 mV 2 kHz to 10 kHz 20 V to 200 V CMC 0,014 % + 3,2 mV 10 kHz to 30 kHz 20 V to 200 V CMC 0,026 % + 5,2 mV 30 kHz to 100 kHz 20 V to 200 V CMC 0,059 % + 24 mV 40 Hz to 10 kHz 200 V to 1000 V CMC 0,015 % + 26 mV 10 kHz to 30 kHz 200 V to 1000 V CMC 0,031 % + 58 mV 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"交流电压 / 交流电压测量仪器和电压源 校准 – 电学量 与标准万用表比较或用其直接测量 40 Hz 至 100 Hz 10 mV 至 200 mV CMC 0,020 % + 15 µV 100 Hz 至 2 kHz 10 mV 至 200 mV CMC 0,015 % + 14 µV 2 kHz 至 10 kHz 10 mV 至 200 mV CMC 0,022 % + 15 µV 10 kHz 至 30 kHz 10 mV 至 200 mV CMC 0,040 % + 15 µV 30 kHz 至 100 kHz 10 mV 至 200 mV CMC 0,089 % + 15 µV 40 Hz 至 100 Hz 200 mV 至 2 V CMC 0,013 % + 32 µV 100 Hz 至 2 kHz 200 mV 至 2 V CMC 0,012 % + 32 µV 2 kHz 至 10 kHz 200 mV 至 2 V CMC 0,013 % + 32 µV 10 kHz 至 30 kHz 200 mV 至 2 V CMC 0,025 % + 52 µV 30 kHz 至 100 kHz 200 mV 至 2 V CMC 0,059 % + 0,24 mV 40 Hz 至 100 Hz 2 V 至 20 V CMC 0,013 % + 0,32 mV 100 Hz 至 2 kHz 2 V 至 20 V CMC 0,012 % + 0,32 mV 2 kHz 至 10 kHz 2 V 至 20 V CMC 0,013 % + 0,32 mV 10 kHz 至 30 kHz 2 V 至 20 V CMC 0,025 % + 0,52 mV 30 kHz 至 100 kHz 2 V 至 20 V CMC 0,059 % + 2,4 mV 40 Hz 至 100 Hz 20 V 至 200 V CMC 0,014 % + 3,2 mV 100 Hz 至 2 kHz 20 V 至 200 V CMC 0,012 % + 3,2 mV 2 kHz 至 10 kHz 20 V 至 200 V CMC 0,014 % + 3,2 mV 10 kHz 至 30 kHz 20 V 至 200 V CMC 0,026 % + 5,2 mV 30 kHz 至 100 kHz 20 V 至 200 V CMC 0,059 % + 24 mV 40 Hz 至 10 kHz 200 V 至 1000 V CMC 0,015 % + 26 mV 10 kHz 至 30 kHz 200 V 至 1000 V CMC 0,031 % + 58 mV 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b871a1c9218cf2e8f688153","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / mierniki do badań instalacji elektrycznych","test_object_en":"AC voltage / inspection equipment","test_object_zh":"交流电压 / 电气安装检测仪","test_object_cs":"Střídavé elektrické napětí / revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz, 60 kHz","range":"od 1 kV do 5 kV","cmc":"0,48 %"}],"parameters_en":[{"name":"50 Hz, 60 kHz","range":"1 kV to 5 kV","cmc":"0,48 %"}],"parameters_zh":[{"name":"50 Hz, 60 kHz","range":"1 kV 至 5 kV","cmc":"0,48 %"}],"parameters_cs":[{"name":"50 Hz, 60 kHz","range":"1 kV až 5 kV","cmc":"0,48 %"}],"technique":"Pomiar kalibratorem mierników do badań instalacji elektrycznych","technique_en":"Measurement by a calibrator of inspection instruments","technique_zh":"用电气安装检测仪校准器测量","technique_cs":"Měření kalibrátorem revizních přístrojů","techniques":["Pomiar kalibratorem mierników do badań instalacji elektrycznych"],"techniques_en":["Measurement by a calibrator of inspection instruments"],"techniques_zh":["用电气安装检测仪校准器测量"],"techniques_cs":["Měření kalibrátorem revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz, 60 kHz od 1 kV do 5 kV CMC 0,48 %\nPomiar kalibratorem mierników do badań instalacji elektrycznych","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Pomiar kalibratorem mierników do badań instalacji elektrycznych 50 Hz, 60 kHz od 1 kV do 5 kV CMC 0,48 % Střídavé elektrické napětí / revizní přístroje Kalibrace – elektrické veličiny Měření kalibrátorem revizních přístrojů 50 Hz, 60 kHz 1 kV až 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9 Napiecie przemienne / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Pomiar kalibratorem miernikow do badan instalacji elektrycznych 50 Hz, 60 kHz od 1 kV do 5 kV CMC 0,48 % Stridave elektricke napeti / revizni pristroje Kalibrace – elektricke veliciny Mereni kalibratorem reviznich pristroju 50 Hz, 60 kHz 1 kV az 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"AC voltage / inspection equipment Calibration – electrical quantities Measurement by a calibrator of inspection instruments 50 Hz, 60 kHz 1 kV to 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"交流电压 / 电气安装检测仪 校准 – 电学量 用电气安装检测仪校准器测量 50 Hz, 60 kHz 1 kV 至 5 kV CMC 0,48 % 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a69ceb87aaa69280f2a32a14","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / przyrządy do pomiaru i źródła prądu przemiennego","test_object_en":"AC current / AC current meters and sources","test_object_zh":"交流电流 / 交流电流测量仪器和电流源","test_object_cs":"Střídavý elektrický proud / měřidla a zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 10 µA do 200 µA","cmc":"0,035 % + 0,024 µA"},{"name":"1 kHz do 5 kHz","range":"od 10 µA do 200 µA","cmc":"0,048 % + 0,024 µA"},{"name":"40 Hz do 1 kHz","range":"od 200 µA do 2 mA","cmc":"0,033 % + 0,24 µA"},{"name":"1 kHz do 5 kHz","range":"od 200 µA do 2 mA","cmc":"0,038 % + 0,24 µA"},{"name":"40 Hz do 1 kHz","range":"od 2 mA do 20 mA","cmc":"0,033 % + 2,4 µA"},{"name":"1 kHz do 5 kHz","range":"od 2 mA do 20 mA","cmc":"0,038 % + 2,4 µA"},{"name":"40 Hz do 1 kHz","range":"od 20 mA do 200 mA","cmc":"0,032 % + 24 µA"},{"name":"1 kHz do 5 kHz","range":"od 20 mA do 200 mA","cmc":"0,037 % + 24 µA"},{"name":"40 Hz do 1 kHz","range":"od 200 mA do 2 A","cmc":"0,075 % + 0,24 mA"},{"name":"1 kHz do 5 kHz","range":"od 200 mA do 2 A","cmc":"0,086 % + 0,24 mA"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"10 µA to 200 µA","cmc":"0,035 % + 0,024 µA"},{"name":"1 kHz to 5 kHz","range":"10 µA to 200 µA","cmc":"0,048 % + 0,024 µA"},{"name":"40 Hz to 1 kHz","range":"200 µA to 2 mA","cmc":"0,033 % + 0,24 µA"},{"name":"1 kHz to 5 kHz","range":"200 µA to 2 mA","cmc":"0,038 % + 0,24 µA"},{"name":"40 Hz to 1 kHz","range":"2 mA to 20 mA","cmc":"0,033 % + 2,4 µA"},{"name":"1 kHz to 5 kHz","range":"2 mA to 20 mA","cmc":"0,038 % + 2,4 µA"},{"name":"40 Hz to 1 kHz","range":"20 mA to 200 mA","cmc":"0,032 % + 24 µA"},{"name":"1 kHz to 5 kHz","range":"20 mA to 200 mA","cmc":"0,037 % + 24 µA"},{"name":"40 Hz to 1 kHz","range":"200 mA to 2 A","cmc":"0,075 % + 0,24 mA"},{"name":"1 kHz to 5 kHz","range":"200 mA to 2 A","cmc":"0,086 % + 0,24 mA"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"10 µA 至 200 µA","cmc":"0,035 % + 0,024 µA"},{"name":"1 kHz 至 5 kHz","range":"10 µA 至 200 µA","cmc":"0,048 % + 0,024 µA"},{"name":"40 Hz 至 1 kHz","range":"200 µA 至 2 mA","cmc":"0,033 % + 0,24 µA"},{"name":"1 kHz 至 5 kHz","range":"200 µA 至 2 mA","cmc":"0,038 % + 0,24 µA"},{"name":"40 Hz 至 1 kHz","range":"2 mA 至 20 mA","cmc":"0,033 % + 2,4 µA"},{"name":"1 kHz 至 5 kHz","range":"2 mA 至 20 mA","cmc":"0,038 % + 2,4 µA"},{"name":"40 Hz 至 1 kHz","range":"20 mA 至 200 mA","cmc":"0,032 % + 24 µA"},{"name":"1 kHz 至 5 kHz","range":"20 mA 至 200 mA","cmc":"0,037 % + 24 µA"},{"name":"40 Hz 至 1 kHz","range":"200 mA 至 2 A","cmc":"0,075 % + 0,24 mA"},{"name":"1 kHz 至 5 kHz","range":"200 mA 至 2 A","cmc":"0,086 % + 0,24 mA"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"10 µA až 200 µA","cmc":"0,035 % + 0,024 µA"},{"name":"1 kHz až 5 kHz","range":"10 µA až 200 µA","cmc":"0,048 % + 0,024 µA"},{"name":"40 Hz až 1 kHz","range":"200 µA až 2 mA","cmc":"0,033 % + 0,24 µA"},{"name":"1 kHz až 5 kHz","range":"200 µA až 2 mA","cmc":"0,038 % + 0,24 µA"},{"name":"40 Hz až 1 kHz","range":"2 mA až 20 mA","cmc":"0,033 % + 2,4 µA"},{"name":"1 kHz až 5 kHz","range":"2 mA až 20 mA","cmc":"0,038 % + 2,4 µA"},{"name":"40 Hz až 1 kHz","range":"20 mA až 200 mA","cmc":"0,032 % + 24 µA"},{"name":"1 kHz až 5 kHz","range":"20 mA až 200 mA","cmc":"0,037 % + 24 µA"},{"name":"40 Hz až 1 kHz","range":"200 mA až 2 A","cmc":"0,075 % + 0,24 mA"},{"name":"1 kHz až 5 kHz","range":"200 mA až 2 A","cmc":"0,086 % + 0,24 mA"}],"technique":"Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","technique_en":"Comparison or direct measurement with a standard multimeter","technique_zh":"与标准万用表比较或用其直接测量","technique_cs":"Porovnání nebo přímé měření pomocí etalonového multimetru","techniques":["Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego"],"techniques_en":["Comparison or direct measurement with a standard multimeter"],"techniques_zh":["与标准万用表比较或用其直接测量"],"techniques_cs":["Porovnání nebo přímé měření pomocí etalonového multimetru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 10 µA do 200 µA CMC 0,035 % + 0,024 µA\n1 kHz do 5 kHz od 10 µA do 200 µA CMC 0,048 % + 0,024 µA\n40 Hz do 1 kHz od 200 µA do 2 mA CMC 0,033 % + 0,24 µA\n1 kHz do 5 kHz od 200 µA do 2 mA CMC 0,038 % + 0,24 µA\n40 Hz do 1 kHz od 2 mA do 20 mA CMC 0,033 % + 2,4 µA\n1 kHz do 5 kHz od 2 mA do 20 mA CMC 0,038 % + 2,4 µA\n40 Hz do 1 kHz od 20 mA do 200 mA CMC 0,032 % + 24 µA\n1 kHz do 5 kHz od 20 mA do 200 mA CMC 0,037 % + 24 µA\n40 Hz do 1 kHz od 200 mA do 2 A CMC 0,075 % + 0,24 mA\n1 kHz do 5 kHz od 200 mA do 2 A CMC 0,086 % + 0,24 mA\nPorównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego 40 Hz do 1 kHz od 10 µA do 200 µA CMC 0,035 % + 0,024 µA 1 kHz do 5 kHz od 10 µA do 200 µA CMC 0,048 % + 0,024 µA 40 Hz do 1 kHz od 200 µA do 2 mA CMC 0,033 % + 0,24 µA 1 kHz do 5 kHz od 200 µA do 2 mA CMC 0,038 % + 0,24 µA 40 Hz do 1 kHz od 2 mA do 20 mA CMC 0,033 % + 2,4 µA 1 kHz do 5 kHz od 2 mA do 20 mA CMC 0,038 % + 2,4 µA 40 Hz do 1 kHz od 20 mA do 200 mA CMC 0,032 % + 24 µA 1 kHz do 5 kHz od 20 mA do 200 mA CMC 0,037 % + 24 µA 40 Hz do 1 kHz od 200 mA do 2 A CMC 0,075 % + 0,24 mA 1 kHz do 5 kHz od 200 mA do 2 A CMC 0,086 % + 0,24 mA Střídavý elektrický proud / měřidla a zdroje střídavého proudu Kalibrace – elektrické veličiny Porovnání nebo přímé měření pomocí etalonového multimetru 40 Hz až 1 kHz 10 µA až 200 µA CMC 0,035 % + 0,024 µA 1 kHz až 5 kHz 10 µA až 200 µA CMC 0,048 % + 0,024 µA 40 Hz až 1 kHz 200 µA až 2 mA CMC 0,033 % + 0,24 µA 1 kHz až 5 kHz 200 µA až 2 mA CMC 0,038 % + 0,24 µA 40 Hz až 1 kHz 2 mA až 20 mA CMC 0,033 % + 2,4 µA 1 kHz až 5 kHz 2 mA až 20 mA CMC 0,038 % + 2,4 µA 40 Hz až 1 kHz 20 mA až 200 mA CMC 0,032 % + 24 µA 1 kHz až 5 kHz 20 mA až 200 mA CMC 0,037 % + 24 µA 40 Hz až 1 kHz 200 mA až 2 A CMC 0,075 % + 0,24 mA 1 kHz až 5 kHz 200 mA až 2 A CMC 0,086 % + 0,24 mA 92/75-17-1, 92/75-17-6, 92/75-17-9 Prad przemienny / przyrzady do pomiaru i zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar bezposredni za pomoca multimetru wzorcowego 40 Hz do 1 kHz od 10 µA do 200 µA CMC 0,035 % + 0,024 µA 1 kHz do 5 kHz od 10 µA do 200 µA CMC 0,048 % + 0,024 µA 40 Hz do 1 kHz od 200 µA do 2 mA CMC 0,033 % + 0,24 µA 1 kHz do 5 kHz od 200 µA do 2 mA CMC 0,038 % + 0,24 µA 40 Hz do 1 kHz od 2 mA do 20 mA CMC 0,033 % + 2,4 µA 1 kHz do 5 kHz od 2 mA do 20 mA CMC 0,038 % + 2,4 µA 40 Hz do 1 kHz od 20 mA do 200 mA CMC 0,032 % + 24 µA 1 kHz do 5 kHz od 20 mA do 200 mA CMC 0,037 % + 24 µA 40 Hz do 1 kHz od 200 mA do 2 A CMC 0,075 % + 0,24 mA 1 kHz do 5 kHz od 200 mA do 2 A CMC 0,086 % + 0,24 mA Stridavy elektricky proud / meridla a zdroje stridaveho proudu Kalibrace – elektricke veliciny Porovnani nebo prime mereni pomoci etalonoveho multimetru 40 Hz az 1 kHz 10 µA az 200 µA CMC 0,035 % + 0,024 µA 1 kHz az 5 kHz 10 µA az 200 µA CMC 0,048 % + 0,024 µA 40 Hz az 1 kHz 200 µA az 2 mA CMC 0,033 % + 0,24 µA 1 kHz az 5 kHz 200 µA az 2 mA CMC 0,038 % + 0,24 µA 40 Hz az 1 kHz 2 mA az 20 mA CMC 0,033 % + 2,4 µA 1 kHz az 5 kHz 2 mA az 20 mA CMC 0,038 % + 2,4 µA 40 Hz az 1 kHz 20 mA az 200 mA CMC 0,032 % + 24 µA 1 kHz az 5 kHz 20 mA az 200 mA CMC 0,037 % + 24 µA 40 Hz az 1 kHz 200 mA az 2 A CMC 0,075 % + 0,24 mA 1 kHz az 5 kHz 200 mA az 2 A CMC 0,086 % + 0,24 mA 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"AC current / AC current meters and sources Calibration – electrical quantities Comparison or direct measurement with a standard multimeter 40 Hz to 1 kHz 10 µA to 200 µA CMC 0,035 % + 0,024 µA 1 kHz to 5 kHz 10 µA to 200 µA CMC 0,048 % + 0,024 µA 40 Hz to 1 kHz 200 µA to 2 mA CMC 0,033 % + 0,24 µA 1 kHz to 5 kHz 200 µA to 2 mA CMC 0,038 % + 0,24 µA 40 Hz to 1 kHz 2 mA to 20 mA CMC 0,033 % + 2,4 µA 1 kHz to 5 kHz 2 mA to 20 mA CMC 0,038 % + 2,4 µA 40 Hz to 1 kHz 20 mA to 200 mA CMC 0,032 % + 24 µA 1 kHz to 5 kHz 20 mA to 200 mA CMC 0,037 % + 24 µA 40 Hz to 1 kHz 200 mA to 2 A CMC 0,075 % + 0,24 mA 1 kHz to 5 kHz 200 mA to 2 A CMC 0,086 % + 0,24 mA 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"交流电流 / 交流电流测量仪器和电流源 校准 – 电学量 与标准万用表比较或用其直接测量 40 Hz 至 1 kHz 10 µA 至 200 µA CMC 0,035 % + 0,024 µA 1 kHz 至 5 kHz 10 µA 至 200 µA CMC 0,048 % + 0,024 µA 40 Hz 至 1 kHz 200 µA 至 2 mA CMC 0,033 % + 0,24 µA 1 kHz 至 5 kHz 200 µA 至 2 mA CMC 0,038 % + 0,24 µA 40 Hz 至 1 kHz 2 mA 至 20 mA CMC 0,033 % + 2,4 µA 1 kHz 至 5 kHz 2 mA 至 20 mA CMC 0,038 % + 2,4 µA 40 Hz 至 1 kHz 20 mA 至 200 mA CMC 0,032 % + 24 µA 1 kHz 至 5 kHz 20 mA 至 200 mA CMC 0,037 % + 24 µA 40 Hz 至 1 kHz 200 mA 至 2 A CMC 0,075 % + 0,24 mA 1 kHz 至 5 kHz 200 mA 至 2 A CMC 0,086 % + 0,24 mA 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"35917c8d6c75f8322bc1bf25","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / przyrządy do pomiaru i źródła prądu przemiennego","test_object_en":"AC current / AC current meters and sources","test_object_zh":"交流电流 / 交流电流测量仪器和电流源","test_object_cs":"Střídavý elektrický proud / měřidla a zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz, 60 Hz","range":"od 2 A do 10 A","cmc":"0,035 % + 0,16 mA"}],"parameters_en":[{"name":"50 Hz, 60 Hz","range":"2 A to 10 A","cmc":"0,035 % + 0,16 mA"}],"parameters_zh":[{"name":"50 Hz, 60 Hz","range":"2 A 至 10 A","cmc":"0,035 % + 0,16 mA"}],"parameters_cs":[{"name":"50 Hz, 60 Hz","range":"2 A až 10 A","cmc":"0,035 % + 0,16 mA"}],"technique":"Porównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym","technique_en":"Comparison or measurement with a standard multimeter with a current shunt","technique_zh":"用带电流分流器的标准万用表比较或测量","technique_cs":"Porovnání nebo měření pomocí etalonového multimetru s proudovým bočníkem","techniques":["Porównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym"],"techniques_en":["Comparison or measurement with a standard multimeter with a current shunt"],"techniques_zh":["用带电流分流器的标准万用表比较或测量"],"techniques_cs":["Porovnání nebo měření pomocí etalonového multimetru s proudovým bočníkem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz, 60 Hz od 2 A do 10 A CMC 0,035 % + 0,16 mA\nPorównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar za pomocą multimetru wzorcowego z bocznikiem prądowym 50 Hz, 60 Hz od 2 A do 10 A CMC 0,035 % + 0,16 mA Střídavý elektrický proud / měřidla a zdroje střídavého proudu Kalibrace – elektrické veličiny Porovnání nebo měření pomocí etalonového multimetru s proudovým bočníkem 50 Hz, 60 Hz 2 A až 10 A CMC 0,035 % + 0,16 mA 92/75-17-1, 92/75-17-6, 92/75-17-9 Prad przemienny / przyrzady do pomiaru i zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar za pomoca multimetru wzorcowego z bocznikiem pradowym 50 Hz, 60 Hz od 2 A do 10 A CMC 0,035 % + 0,16 mA Stridavy elektricky proud / meridla a zdroje stridaveho proudu Kalibrace – elektricke veliciny Porovnani nebo mereni pomoci etalonoveho multimetru s proudovym bocnikem 50 Hz, 60 Hz 2 A az 10 A CMC 0,035 % + 0,16 mA 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"AC current / AC current meters and sources Calibration – electrical quantities Comparison or measurement with a standard multimeter with a current shunt 50 Hz, 60 Hz 2 A to 10 A CMC 0,035 % + 0,16 mA 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"交流电流 / 交流电流测量仪器和电流源 校准 – 电学量 用带电流分流器的标准万用表比较或测量 50 Hz, 60 Hz 2 A 至 10 A CMC 0,035 % + 0,16 mA 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ca8b23b2c41921d81dd9d13c","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / przyrządy do pomiaru i źródła prądu przemiennego","test_object_en":"AC current / AC current meters and sources","test_object_zh":"交流电流 / 交流电流测量仪器和电流源","test_object_cs":"Střídavý elektrický proud / měřidla a zdroje střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz, 60 Hz","range":"od 10 A do 1000 A","cmc":"0,33 %"}],"parameters_en":[{"name":"50 Hz, 60 Hz","range":"10 A to 1000 A","cmc":"0,33 %"}],"parameters_zh":[{"name":"50 Hz, 60 Hz","range":"10 A 至 1000 A","cmc":"0,33 %"}],"parameters_cs":[{"name":"50 Hz, 60 Hz","range":"10 A až 1000 A","cmc":"0,33 %"}],"technique":"Porównanie lub pomiar za pomocą multimetru wzorcowego z przekładnikiem prądowym","technique_en":"Comparison or measurement with a standard multimeter with a current transformer","technique_zh":"用带电流互感器的标准万用表比较或测量","technique_cs":"Porovnání nebo měření pomocí etalonového multimetru s proudovým transformátorem","techniques":["Porównanie lub pomiar za pomocą multimetru wzorcowego z przekładnikiem prądowym"],"techniques_en":["Comparison or measurement with a standard multimeter with a current transformer"],"techniques_zh":["用带电流互感器的标准万用表比较或测量"],"techniques_cs":["Porovnání nebo měření pomocí etalonového multimetru s proudovým transformátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz, 60 Hz od 10 A do 1000 A CMC 0,33 %\nPorównanie lub pomiar za pomocą multimetru wzorcowego z przekładnikiem prądowym","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i źródła prądu przemiennego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar za pomocą multimetru wzorcowego z przekładnikiem prądowym 50 Hz, 60 Hz od 10 A do 1000 A CMC 0,33 % Střídavý elektrický proud / měřidla a zdroje střídavého proudu Kalibrace – elektrické veličiny Porovnání nebo měření pomocí etalonového multimetru s proudovým transformátorem 50 Hz, 60 Hz 10 A až 1000 A CMC 0,33 % 92/75-17-1, 92/75-17-6, 92/75-17-9 Prad przemienny / przyrzady do pomiaru i zrodla pradu przemiennego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar za pomoca multimetru wzorcowego z przekladnikiem pradowym 50 Hz, 60 Hz od 10 A do 1000 A CMC 0,33 % Stridavy elektricky proud / meridla a zdroje stridaveho proudu Kalibrace – elektricke veliciny Porovnani nebo mereni pomoci etalonoveho multimetru s proudovym transformatorem 50 Hz, 60 Hz 10 A az 1000 A CMC 0,33 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"AC current / AC current meters and sources Calibration – electrical quantities Comparison or measurement with a standard multimeter with a current transformer 50 Hz, 60 Hz 10 A to 1000 A CMC 0,33 % 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"交流电流 / 交流电流测量仪器和电流源 校准 – 电学量 用带电流互感器的标准万用表比较或测量 50 Hz, 60 Hz 10 A 至 1000 A CMC 0,33 % 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"56de9390b6f22aaa483622b6","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"4","test_object":"Prąd przemienny / mierniki cęgowe","test_object_en":"AC current / clamp testers","test_object_zh":"交流电流 / 钳形仪表","test_object_cs":"Střídavý elektrický proud / klešťové přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz, 60 Hz","range":"od 0,1 A do 1000 A","cmc":"0,36 % + 0,12 A"}],"parameters_en":[{"name":"50 Hz, 60 Hz","range":"0,1 A to 1000 A","cmc":"0,36 % + 0,12 A"}],"parameters_zh":[{"name":"50 Hz, 60 Hz","range":"0,1 A 至 1000 A","cmc":"0,36 % + 0,12 A"}],"parameters_cs":[{"name":"50 Hz, 60 Hz","range":"0,1 A až 1000 A","cmc":"0,36 % + 0,12 A"}],"technique":"Pomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową","technique_en":"Measurement of current simulated by a standard calibrator with current coil","technique_zh":"测量由带电流线圈的标准校准器模拟的电流","technique_cs":"Měření proudu simulovaného etalonovým kalibrátorem s proudovou cívkou","techniques":["Pomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową"],"techniques_en":["Measurement of current simulated by a standard calibrator with current coil"],"techniques_zh":["测量由带电流线圈的标准校准器模拟的电流"],"techniques_cs":["Měření proudu simulovaného etalonovým kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz, 60 Hz od 0,1 A do 1000 A CMC 0,36 % + 0,12 A\nPomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową","reference":"92/75-17-1, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-1","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / mierniki cęgowe Wzorcowanie – wielkości elektryczne Pomiar prądu symulowanego kalibratorem wzorcowym z cewką prądową 50 Hz, 60 Hz od 0,1 A do 1000 A CMC 0,36 % + 0,12 A Střídavý elektrický proud / klešťové přístroje Kalibrace – elektrické veličiny Měření proudu simulovaného etalonovým kalibrátorem s proudovou cívkou 50 Hz, 60 Hz 0,1 A až 1000 A CMC 0,36 % + 0,12 A 92/75-17-1, 92/75-17-6, 92/75-17-9 Prad przemienny / mierniki cegowe Wzorcowanie – wielkosci elektryczne Pomiar pradu symulowanego kalibratorem wzorcowym z cewka pradowa 50 Hz, 60 Hz od 0,1 A do 1000 A CMC 0,36 % + 0,12 A Stridavy elektricky proud / klestove pristroje Kalibrace – elektricke veliciny Mereni proudu simulovaneho etalonovym kalibratorem s proudovou civkou 50 Hz, 60 Hz 0,1 A az 1000 A CMC 0,36 % + 0,12 A 92/75-17-1, 92/75-17-6, 92/75-17-9","search_en":"AC current / clamp testers Calibration – electrical quantities Measurement of current simulated by a standard calibrator with current coil 50 Hz, 60 Hz 0,1 A to 1000 A CMC 0,36 % + 0,12 A 92/75-17-1, 92/75-17-6, 92/75-17-9","search_zh":"交流电流 / 钳形仪表 校准 – 电学量 测量由带电流线圈的标准校准器模拟的电流 50 Hz, 60 Hz 0,1 A 至 1000 A CMC 0,36 % + 0,12 A 92/75-17-1, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc155b503f31dfaa81f32d22","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja / wzorce rezystancji dla prądu stałego","test_object_en":"Electrical resistance / DC resistance standards","test_object_zh":"电阻 / 直流电阻标准器","test_object_cs":"Elektrický odpor / etalony stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0,1 mΩ","cmc":"0,012 %"},{"name":"","range":"1 mΩ","cmc":"0,0030 %"},{"name":"","range":"10 mΩ","cmc":"0,0015 %"},{"name":"","range":"0,1 Ω","cmc":"0,0015 %"},{"name":"","range":"1 Ω","cmc":"0,0015 %"},{"name":"","range":"10 Ω","cmc":"0,0015 %"},{"name":"","range":"100 Ω","cmc":"0,0015 %"},{"name":"","range":"1 kΩ","cmc":"0,0015 %"},{"name":"","range":"10 kΩ","cmc":"0,0015 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"}],"parameters_en":[{"name":"","range":"0,1 mΩ","cmc":"0,012 %"},{"name":"","range":"1 mΩ","cmc":"0,0030 %"},{"name":"","range":"10 mΩ","cmc":"0,0015 %"},{"name":"","range":"0,1 Ω","cmc":"0,0015 %"},{"name":"","range":"1 Ω","cmc":"0,0015 %"},{"name":"","range":"10 Ω","cmc":"0,0015 %"},{"name":"","range":"100 Ω","cmc":"0,0015 %"},{"name":"","range":"1 kΩ","cmc":"0,0015 %"},{"name":"","range":"10 kΩ","cmc":"0,0015 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"}],"parameters_zh":[{"name":"","range":"0,1 mΩ","cmc":"0,012 %"},{"name":"","range":"1 mΩ","cmc":"0,0030 %"},{"name":"","range":"10 mΩ","cmc":"0,0015 %"},{"name":"","range":"0,1 Ω","cmc":"0,0015 %"},{"name":"","range":"1 Ω","cmc":"0,0015 %"},{"name":"","range":"10 Ω","cmc":"0,0015 %"},{"name":"","range":"100 Ω","cmc":"0,0015 %"},{"name":"","range":"1 kΩ","cmc":"0,0015 %"},{"name":"","range":"10 kΩ","cmc":"0,0015 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"}],"parameters_cs":[{"name":"","range":"0,1 mΩ","cmc":"0,012 %"},{"name":"","range":"1 mΩ","cmc":"0,0030 %"},{"name":"","range":"10 mΩ","cmc":"0,0015 %"},{"name":"","range":"0,1 Ω","cmc":"0,0015 %"},{"name":"","range":"1 Ω","cmc":"0,0015 %"},{"name":"","range":"10 Ω","cmc":"0,0015 %"},{"name":"","range":"100 Ω","cmc":"0,0015 %"},{"name":"","range":"1 kΩ","cmc":"0,0015 %"},{"name":"","range":"10 kΩ","cmc":"0,0015 %"},{"name":"","range":"100 kΩ","cmc":"0,0015 %"}],"technique":"Porównanie z wzorcem rezystancji metodą substytucji","technique_en":"Comparison with the resistance standard by the substitution method","technique_zh":"用替代法与电阻标准器比较","technique_cs":"Porovnání s etalonem odporu substituční metodou","techniques":["Porównanie z wzorcem rezystancji metodą substytucji"],"techniques_en":["Comparison with the resistance standard by the substitution method"],"techniques_zh":["用替代法与电阻标准器比较"],"techniques_cs":["Porovnání s etalonem odporu substituční metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 mΩ CMC 0,012 %\n1 mΩ CMC 0,0030 %\n10 mΩ CMC 0,0015 %\n0,1 Ω CMC 0,0015 %\n1 Ω CMC 0,0015 %\n10 Ω CMC 0,0015 %\n100 Ω CMC 0,0015 %\n1 kΩ CMC 0,0015 %\n10 kΩ CMC 0,0015 %\n100 kΩ CMC 0,0015 %\nPorównanie z wzorcem rezystancji metodą substytucji","reference":"92/75-17-5, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-5","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja / wzorce rezystancji dla prądu stałego Wzorcowanie – wielkości elektryczne Porównanie z wzorcem rezystancji metodą substytucji 0,1 mΩ CMC 0,012 % 1 mΩ CMC 0,0030 % 10 mΩ CMC 0,0015 % 0,1 Ω CMC 0,0015 % 1 Ω CMC 0,0015 % 10 Ω CMC 0,0015 % 100 Ω CMC 0,0015 % 1 kΩ CMC 0,0015 % 10 kΩ CMC 0,0015 % 100 kΩ CMC 0,0015 % Elektrický odpor / etalony stejnosměrného odporu Kalibrace – elektrické veličiny Porovnání s etalonem odporu substituční metodou 0,1 mΩ CMC 0,012 % 1 mΩ CMC 0,0030 % 10 mΩ CMC 0,0015 % 0,1 Ω CMC 0,0015 % 1 Ω CMC 0,0015 % 10 Ω CMC 0,0015 % 100 Ω CMC 0,0015 % 1 kΩ CMC 0,0015 % 10 kΩ CMC 0,0015 % 100 kΩ CMC 0,0015 % 92/75-17-5, 92/75-17-6, 92/75-17-9 Rezystancja / wzorce rezystancji dla pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie z wzorcem rezystancji metoda substytucji 0,1 mΩ CMC 0,012 % 1 mΩ CMC 0,0030 % 10 mΩ CMC 0,0015 % 0,1 Ω CMC 0,0015 % 1 Ω CMC 0,0015 % 10 Ω CMC 0,0015 % 100 Ω CMC 0,0015 % 1 kΩ CMC 0,0015 % 10 kΩ CMC 0,0015 % 100 kΩ CMC 0,0015 % Elektricky odpor / etalony stejnosmerneho odporu Kalibrace – elektricke veliciny Porovnani s etalonem odporu substitucni metodou 0,1 mΩ CMC 0,012 % 1 mΩ CMC 0,0030 % 10 mΩ CMC 0,0015 % 0,1 Ω CMC 0,0015 % 1 Ω CMC 0,0015 % 10 Ω CMC 0,0015 % 100 Ω CMC 0,0015 % 1 kΩ CMC 0,0015 % 10 kΩ CMC 0,0015 % 100 kΩ CMC 0,0015 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_en":"Electrical resistance / DC resistance standards Calibration – electrical quantities Comparison with the resistance standard by the substitution method 0,1 mΩ CMC 0,012 % 1 mΩ CMC 0,0030 % 10 mΩ CMC 0,0015 % 0,1 Ω CMC 0,0015 % 1 Ω CMC 0,0015 % 10 Ω CMC 0,0015 % 100 Ω CMC 0,0015 % 1 kΩ CMC 0,0015 % 10 kΩ CMC 0,0015 % 100 kΩ CMC 0,0015 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_zh":"电阻 / 直流电阻标准器 校准 – 电学量 用替代法与电阻标准器比较 0,1 mΩ CMC 0,012 % 1 mΩ CMC 0,0030 % 10 mΩ CMC 0,0015 % 0,1 Ω CMC 0,0015 % 1 Ω CMC 0,0015 % 10 Ω CMC 0,0015 % 100 Ω CMC 0,0015 % 1 kΩ CMC 0,0015 % 10 kΩ CMC 0,0015 % 100 kΩ CMC 0,0015 % 92/75-17-5, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15b32c76a6732e0f72a11a9d","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja / mierniki i generatory rezystancji dla prądu stałego","test_object_en":"Electrical resistance / DC resistance meters and generators","test_object_zh":"电阻 / 直流电阻测量仪和发生器","test_object_cs":"Elektrický odpor / měřiče a generátory stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,01 Ω do 0,1 Ω","cmc":"0,015 %"},{"name":"","range":"od 0,1 Ω do 1 Ω","cmc":"0,011 %"}],"parameters_en":[{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"0,015 %"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,011 %"}],"parameters_zh":[{"name":"","range":"0,01 Ω 至 0,1 Ω","cmc":"0,015 %"},{"name":"","range":"0,1 Ω 至 1 Ω","cmc":"0,011 %"}],"parameters_cs":[{"name":"","range":"0,01 Ω až 0,1 Ω","cmc":"0,015 %"},{"name":"","range":"0,1 Ω až 1 Ω","cmc":"0,011 %"}],"technique":"Porównanie lub pomiar metodą Ohma","technique_en":"Comparison or measurement using the Ohm method","technique_zh":"用欧姆法比较或测量","technique_cs":"Porovnání nebo měření Ohmovou metodou","techniques":["Porównanie lub pomiar metodą Ohma"],"techniques_en":["Comparison or measurement using the Ohm method"],"techniques_zh":["用欧姆法比较或测量"],"techniques_cs":["Porovnání nebo měření Ohmovou metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,01 Ω do 0,1 Ω CMC 0,015 %\nod 0,1 Ω do 1 Ω CMC 0,011 %\nPorównanie lub pomiar metodą Ohma","reference":"92/75-17-5, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-5","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja / mierniki i generatory rezystancji dla prądu stałego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar metodą Ohma od 0,01 Ω do 0,1 Ω CMC 0,015 % od 0,1 Ω do 1 Ω CMC 0,011 % Elektrický odpor / měřiče a generátory stejnosměrného odporu Kalibrace – elektrické veličiny Porovnání nebo měření Ohmovou metodou 0,01 Ω až 0,1 Ω CMC 0,015 % 0,1 Ω až 1 Ω CMC 0,011 % 92/75-17-5, 92/75-17-6, 92/75-17-9 Rezystancja / mierniki i generatory rezystancji dla pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar metoda Ohma od 0,01 Ω do 0,1 Ω CMC 0,015 % od 0,1 Ω do 1 Ω CMC 0,011 % Elektricky odpor / merice a generatory stejnosmerneho odporu Kalibrace – elektricke veliciny Porovnani nebo mereni Ohmovou metodou 0,01 Ω az 0,1 Ω CMC 0,015 % 0,1 Ω az 1 Ω CMC 0,011 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_en":"Electrical resistance / DC resistance meters and generators Calibration – electrical quantities Comparison or measurement using the Ohm method 0,01 Ω to 0,1 Ω CMC 0,015 % 0,1 Ω to 1 Ω CMC 0,011 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_zh":"电阻 / 直流电阻测量仪和发生器 校准 – 电学量 用欧姆法比较或测量 0,01 Ω 至 0,1 Ω CMC 0,015 % 0,1 Ω 至 1 Ω CMC 0,011 % 92/75-17-5, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25e04ba5c372407fb88ea40e","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja / mierniki i generatory rezystancji dla prądu stałego","test_object_en":"Electrical resistance / DC resistance meters and generators","test_object_zh":"电阻 / 直流电阻测量仪和发生器","test_object_cs":"Elektrický odpor / měřiče a generátory stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 Ω do 20 Ω","cmc":"0,0034 %"},{"name":"","range":"od 20 Ω do 200 Ω","cmc":"0,0022 %"},{"name":"","range":"od 200 Ω do 20 kΩ","cmc":"0,0018 %"},{"name":"","range":"od 20 kΩ do 200 kΩ","cmc":"0,0022 %"},{"name":"","range":"od 200 kΩ do 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"od 2 MΩ do 20 MΩ","cmc":"0,0076 %"},{"name":"","range":"od 20 MΩ do 100 MΩ","cmc":"0,058 %"},{"name":"","range":"od 100 MΩ do 1 GΩ","cmc":"0,65 %"},{"name":"","range":"od 1 GΩ do 10 GΩ","cmc":"1,2 %"}],"parameters_en":[{"name":"","range":"1 Ω to 20 Ω","cmc":"0,0034 %"},{"name":"","range":"20 Ω to 200 Ω","cmc":"0,0022 %"},{"name":"","range":"200 Ω to 20 kΩ","cmc":"0,0018 %"},{"name":"","range":"20 kΩ to 200 kΩ","cmc":"0,0022 %"},{"name":"","range":"200 kΩ to 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"2 MΩ to 20 MΩ","cmc":"0,0076 %"},{"name":"","range":"20 MΩ to 100 MΩ","cmc":"0,058 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,65 %"},{"name":"","range":"1 GΩ to 10 GΩ","cmc":"1,2 %"}],"parameters_zh":[{"name":"","range":"1 Ω 至 20 Ω","cmc":"0,0034 %"},{"name":"","range":"20 Ω 至 200 Ω","cmc":"0,0022 %"},{"name":"","range":"200 Ω 至 20 kΩ","cmc":"0,0018 %"},{"name":"","range":"20 kΩ 至 200 kΩ","cmc":"0,0022 %"},{"name":"","range":"200 kΩ 至 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"2 MΩ 至 20 MΩ","cmc":"0,0076 %"},{"name":"","range":"20 MΩ 至 100 MΩ","cmc":"0,058 %"},{"name":"","range":"100 MΩ 至 1 GΩ","cmc":"0,65 %"},{"name":"","range":"1 GΩ 至 10 GΩ","cmc":"1,2 %"}],"parameters_cs":[{"name":"","range":"1 Ω až 20 Ω","cmc":"0,0034 %"},{"name":"","range":"20 Ω až 200 Ω","cmc":"0,0022 %"},{"name":"","range":"200 Ω až 20 kΩ","cmc":"0,0018 %"},{"name":"","range":"20 kΩ až 200 kΩ","cmc":"0,0022 %"},{"name":"","range":"200 kΩ až 2 MΩ","cmc":"0,0040 %"},{"name":"","range":"2 MΩ až 20 MΩ","cmc":"0,0076 %"},{"name":"","range":"20 MΩ až 100 MΩ","cmc":"0,058 %"},{"name":"","range":"100 MΩ až 1 GΩ","cmc":"0,65 %"},{"name":"","range":"1 GΩ až 10 GΩ","cmc":"1,2 %"}],"technique":"Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","technique_en":"Comparison or direct measurement with a standard multimeter","technique_zh":"与标准万用表比较或用其直接测量","technique_cs":"Porovnání nebo přímé měření pomocí etalonového multimetru","techniques":["Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego"],"techniques_en":["Comparison or direct measurement with a standard multimeter"],"techniques_zh":["与标准万用表比较或用其直接测量"],"techniques_cs":["Porovnání nebo přímé měření pomocí etalonového multimetru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 Ω do 20 Ω CMC 0,0034 %\nod 20 Ω do 200 Ω CMC 0,0022 %\nod 200 Ω do 20 kΩ CMC 0,0018 %\nod 20 kΩ do 200 kΩ CMC 0,0022 %\nod 200 kΩ do 2 MΩ CMC 0,0040 %\nod 2 MΩ do 20 MΩ CMC 0,0076 %\nod 20 MΩ do 100 MΩ CMC 0,058 %\nod 100 MΩ do 1 GΩ CMC 0,65 %\nod 1 GΩ do 10 GΩ CMC 1,2 %\nPorównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego","reference":"92/75-17-5, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-5","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja / mierniki i generatory rezystancji dla prądu stałego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar bezpośredni za pomocą multimetru wzorcowego od 1 Ω do 20 Ω CMC 0,0034 % od 20 Ω do 200 Ω CMC 0,0022 % od 200 Ω do 20 kΩ CMC 0,0018 % od 20 kΩ do 200 kΩ CMC 0,0022 % od 200 kΩ do 2 MΩ CMC 0,0040 % od 2 MΩ do 20 MΩ CMC 0,0076 % od 20 MΩ do 100 MΩ CMC 0,058 % od 100 MΩ do 1 GΩ CMC 0,65 % od 1 GΩ do 10 GΩ CMC 1,2 % Elektrický odpor / měřiče a generátory stejnosměrného odporu Kalibrace – elektrické veličiny Porovnání nebo přímé měření pomocí etalonového multimetru 1 Ω až 20 Ω CMC 0,0034 % 20 Ω až 200 Ω CMC 0,0022 % 200 Ω až 20 kΩ CMC 0,0018 % 20 kΩ až 200 kΩ CMC 0,0022 % 200 kΩ až 2 MΩ CMC 0,0040 % 2 MΩ až 20 MΩ CMC 0,0076 % 20 MΩ až 100 MΩ CMC 0,058 % 100 MΩ až 1 GΩ CMC 0,65 % 1 GΩ až 10 GΩ CMC 1,2 % 92/75-17-5, 92/75-17-6, 92/75-17-9 Rezystancja / mierniki i generatory rezystancji dla pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar bezposredni za pomoca multimetru wzorcowego od 1 Ω do 20 Ω CMC 0,0034 % od 20 Ω do 200 Ω CMC 0,0022 % od 200 Ω do 20 kΩ CMC 0,0018 % od 20 kΩ do 200 kΩ CMC 0,0022 % od 200 kΩ do 2 MΩ CMC 0,0040 % od 2 MΩ do 20 MΩ CMC 0,0076 % od 20 MΩ do 100 MΩ CMC 0,058 % od 100 MΩ do 1 GΩ CMC 0,65 % od 1 GΩ do 10 GΩ CMC 1,2 % Elektricky odpor / merice a generatory stejnosmerneho odporu Kalibrace – elektricke veliciny Porovnani nebo prime mereni pomoci etalonoveho multimetru 1 Ω az 20 Ω CMC 0,0034 % 20 Ω az 200 Ω CMC 0,0022 % 200 Ω az 20 kΩ CMC 0,0018 % 20 kΩ az 200 kΩ CMC 0,0022 % 200 kΩ az 2 MΩ CMC 0,0040 % 2 MΩ az 20 MΩ CMC 0,0076 % 20 MΩ az 100 MΩ CMC 0,058 % 100 MΩ az 1 GΩ CMC 0,65 % 1 GΩ az 10 GΩ CMC 1,2 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_en":"Electrical resistance / DC resistance meters and generators Calibration – electrical quantities Comparison or direct measurement with a standard multimeter 1 Ω to 20 Ω CMC 0,0034 % 20 Ω to 200 Ω CMC 0,0022 % 200 Ω to 20 kΩ CMC 0,0018 % 20 kΩ to 200 kΩ CMC 0,0022 % 200 kΩ to 2 MΩ CMC 0,0040 % 2 MΩ to 20 MΩ CMC 0,0076 % 20 MΩ to 100 MΩ CMC 0,058 % 100 MΩ to 1 GΩ CMC 0,65 % 1 GΩ to 10 GΩ CMC 1,2 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_zh":"电阻 / 直流电阻测量仪和发生器 校准 – 电学量 与标准万用表比较或用其直接测量 1 Ω 至 20 Ω CMC 0,0034 % 20 Ω 至 200 Ω CMC 0,0022 % 200 Ω 至 20 kΩ CMC 0,0018 % 20 kΩ 至 200 kΩ CMC 0,0022 % 200 kΩ 至 2 MΩ CMC 0,0040 % 2 MΩ 至 20 MΩ CMC 0,0076 % 20 MΩ 至 100 MΩ CMC 0,058 % 100 MΩ 至 1 GΩ CMC 0,65 % 1 GΩ 至 10 GΩ CMC 1,2 % 92/75-17-5, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"83957951380816b0c2115406","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"5","test_object":"Rezystancja / mierniki i generatory rezystancji dla prądu stałego","test_object_en":"Electrical resistance / DC resistance meters and generators","test_object_zh":"电阻 / 直流电阻测量仪和发生器","test_object_cs":"Elektrický odpor / měřiče a generátory stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 10 GΩ do 100 GΩ","cmc":"3,5 %"}],"parameters_en":[{"name":"","range":"10 GΩ to 100 GΩ","cmc":"3,5 %"}],"parameters_zh":[{"name":"","range":"10 GΩ 至 100 GΩ","cmc":"3,5 %"}],"parameters_cs":[{"name":"","range":"10 GΩ až 100 GΩ","cmc":"3,5 %"}],"technique":"Generowanie za pomocą kalibratora mierników do badań instalacji elektrycznych","technique_en":"Generation by a calibrator of inspection instruments","technique_zh":"用电气安装检测仪校准器产生","technique_cs":"Generování pomocí kalibrátoru revizních přístrojů","techniques":["Generowanie za pomocą kalibratora mierników do badań instalacji elektrycznych"],"techniques_en":["Generation by a calibrator of inspection instruments"],"techniques_zh":["用电气安装检测仪校准器产生"],"techniques_cs":["Generování pomocí kalibrátoru revizních přístrojů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 10 GΩ do 100 GΩ CMC 3,5 %\nGenerowanie za pomocą kalibratora mierników do badań instalacji elektrycznych","reference":"92/75-17-5, 92/75-17-6, 92/75-17-9","norm_bases":["92/75-17-5","92/75-17-6","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja / mierniki i generatory rezystancji dla prądu stałego Wzorcowanie – wielkości elektryczne Generowanie za pomocą kalibratora mierników do badań instalacji elektrycznych od 10 GΩ do 100 GΩ CMC 3,5 % Elektrický odpor / měřiče a generátory stejnosměrného odporu Kalibrace – elektrické veličiny Generování pomocí kalibrátoru revizních přístrojů 10 GΩ až 100 GΩ CMC 3,5 % 92/75-17-5, 92/75-17-6, 92/75-17-9 Rezystancja / mierniki i generatory rezystancji dla pradu stalego Wzorcowanie – wielkosci elektryczne Generowanie za pomoca kalibratora miernikow do badan instalacji elektrycznych od 10 GΩ do 100 GΩ CMC 3,5 % Elektricky odpor / merice a generatory stejnosmerneho odporu Kalibrace – elektricke veliciny Generovani pomoci kalibratoru reviznich pristroju 10 GΩ az 100 GΩ CMC 3,5 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_en":"Electrical resistance / DC resistance meters and generators Calibration – electrical quantities Generation by a calibrator of inspection instruments 10 GΩ to 100 GΩ CMC 3,5 % 92/75-17-5, 92/75-17-6, 92/75-17-9","search_zh":"电阻 / 直流电阻测量仪和发生器 校准 – 电学量 用电气安装检测仪校准器产生 10 GΩ 至 100 GΩ CMC 3,5 % 92/75-17-5, 92/75-17-6, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1da112724f87dd84218aafed","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"6","test_object":"Moc prądu stałego / watomierze prądu stałego i generatory mocy prądu stałego","test_object_en":"DC power / DC wattmeters and DC power generators","test_object_zh":"直流功率 / 直流功率表和直流功率发生器","test_object_cs":"Stejnosměrný elektrický výkon / stejnosměrné wattmetry a generátory stejnosměrného výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,1 V do 1000 V; 1 mA do 20 mA","range":"od 0,1 mW do 100 kW","cmc":"0,0092 %"}],"parameters_en":[{"name":"0,1 V to 1000 V; 1 mA to 20 mA","range":"0,1 mW to 100 kW","cmc":"0,0092 %"}],"parameters_zh":[{"name":"0,1 V 至 1000 V；1 mA 至 20 mA","range":"0,1 mW 至 100 kW","cmc":"0,0092 %"}],"parameters_cs":[{"name":"0,1 V až 1000 V; 1 mA až 20 mA","range":"0,1 mW až 100 kW","cmc":"0,0092 %"}],"technique":"Porównanie lub pomiar za pomocą dwóch multimetrów wzorcowych","technique_en":"Comparison or measurement with two standard multimeters","technique_zh":"用两台标准万用表比较或测量","technique_cs":"Porovnání nebo měření pomocí dvou etalonových multimetrů","techniques":["Porównanie lub pomiar za pomocą dwóch multimetrów wzorcowych"],"techniques_en":["Comparison or measurement with two standard multimeters"],"techniques_zh":["用两台标准万用表比较或测量"],"techniques_cs":["Porovnání nebo měření pomocí dvou etalonových multimetrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n0,1 V do 1000 V; 1 mA do 20 mA od 0,1 mW do 100 kW CMC 0,0092 %\nPorównanie lub pomiar za pomocą dwóch multimetrów wzorcowych","reference":"92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","norm_bases":["92/75-17-5","92/75-17-6","92/75-17-7","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / watomierze prądu stałego i generatory mocy prądu stałego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar za pomocą dwóch multimetrów wzorcowych 0,1 V do 1000 V; 1 mA do 20 mA od 0,1 mW do 100 kW CMC 0,0092 % Stejnosměrný elektrický výkon / stejnosměrné wattmetry a generátory stejnosměrného výkonu Kalibrace – elektrické veličiny Porovnání nebo měření pomocí dvou etalonových multimetrů 0,1 V až 1000 V; 1 mA až 20 mA 0,1 mW až 100 kW CMC 0,0092 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9 Moc pradu stalego / watomierze pradu stalego i generatory mocy pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar za pomoca dwoch multimetrow wzorcowych 0,1 V do 1000 V; 1 mA do 20 mA od 0,1 mW do 100 kW CMC 0,0092 % Stejnosmerny elektricky vykon / stejnosmerne wattmetry a generatory stejnosmerneho vykonu Kalibrace – elektricke veliciny Porovnani nebo mereni pomoci dvou etalonovych multimetru 0,1 V az 1000 V; 1 mA az 20 mA 0,1 mW az 100 kW CMC 0,0092 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","search_en":"DC power / DC wattmeters and DC power generators Calibration – electrical quantities Comparison or measurement with two standard multimeters 0,1 V to 1000 V; 1 mA to 20 mA 0,1 mW to 100 kW CMC 0,0092 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","search_zh":"直流功率 / 直流功率表和直流功率发生器 校准 – 电学量 用两台标准万用表比较或测量 0,1 V 至 1000 V；1 mA 至 20 mA 0,1 mW 至 100 kW CMC 0,0092 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ecbbab4d3a41f2487600e58","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"6","test_object":"Moc prądu stałego / watomierze prądu stałego i generatory mocy prądu stałego","test_object_en":"DC power / DC wattmeters and DC power generators","test_object_zh":"直流功率 / 直流功率表和直流功率发生器","test_object_cs":"Stejnosměrný elektrický výkon / stejnosměrné wattmetry a generátory stejnosměrného výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,1 V do 1000 V; 20 mA do 200 mA","range":"od 0,1 mW do 100 kW","cmc":"0,0065 %"},{"name":"0,1 V do 1000 V; 200 mA do 10 A","range":"od 0,1 mW do 100 kW","cmc":"0,0070 %"},{"name":"0,1 V do 1000 V; 10 A do 100 A","range":"od 0,1 mW do 100 kW","cmc":"0,013 %"}],"parameters_en":[{"name":"0,1 V to 1000 V; 20 mA to 200 mA","range":"0,1 mW to 100 kW","cmc":"0,0065 %"},{"name":"0,1 V to 1000 V; 200 mA to 10 A","range":"0,1 mW to 100 kW","cmc":"0,0070 %"},{"name":"0,1 V to 1000 V; 10 A to 100 A","range":"0,1 mW to 100 kW","cmc":"0,013 %"}],"parameters_zh":[{"name":"0,1 V 至 1000 V；20 mA 至 200 mA","range":"0,1 mW 至 100 kW","cmc":"0,0065 %"},{"name":"0,1 V 至 1000 V；200 mA 至 10 A","range":"0,1 mW 至 100 kW","cmc":"0,0070 %"},{"name":"0,1 V 至 1000 V；10 A 至 100 A","range":"0,1 mW 至 100 kW","cmc":"0,013 %"}],"parameters_cs":[{"name":"0,1 V až 1000 V; 20 mA až 200 mA","range":"0,1 mW až 100 kW","cmc":"0,0065 %"},{"name":"0,1 V až 1000 V; 200 mA až 10 A","range":"0,1 mW až 100 kW","cmc":"0,0070 %"},{"name":"0,1 V až 1000 V; 10 A až 100 A","range":"0,1 mW až 100 kW","cmc":"0,013 %"}],"technique":"Porównanie lub pomiar za pomocą dwóch multimetrów wzorcowych i bocznika prądowego","technique_en":"Comparison or measurement with two standard multimeters and a current shunt","technique_zh":"用两台标准万用表和电流分流器比较或测量","technique_cs":"Porovnání nebo měření pomocí dvou etalonových multimetrů a proudového bočníku","techniques":["Porównanie lub pomiar za pomocą dwóch multimetrów wzorcowych i bocznika prądowego"],"techniques_en":["Comparison or measurement with two standard multimeters and a current shunt"],"techniques_zh":["用两台标准万用表和电流分流器比较或测量"],"techniques_cs":["Porovnání nebo měření pomocí dvou etalonových multimetrů a proudového bočníku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,1 V do 1000 V; 20 mA do 200 mA od 0,1 mW do 100 kW CMC 0,0065 %\n0,1 V do 1000 V; 200 mA do 10 A od 0,1 mW do 100 kW CMC 0,0070 %\n0,1 V do 1000 V; 10 A do 100 A od 0,1 mW do 100 kW CMC 0,013 %\nPorównanie lub pomiar za pomocą dwóch multimetrów wzorcowych i bocznika prądowego","reference":"92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","norm_bases":["92/75-17-5","92/75-17-6","92/75-17-7","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / watomierze prądu stałego i generatory mocy prądu stałego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar za pomocą dwóch multimetrów wzorcowych i bocznika prądowego 0,1 V do 1000 V; 20 mA do 200 mA od 0,1 mW do 100 kW CMC 0,0065 % 0,1 V do 1000 V; 200 mA do 10 A od 0,1 mW do 100 kW CMC 0,0070 % 0,1 V do 1000 V; 10 A do 100 A od 0,1 mW do 100 kW CMC 0,013 % Stejnosměrný elektrický výkon / stejnosměrné wattmetry a generátory stejnosměrného výkonu Kalibrace – elektrické veličiny Porovnání nebo měření pomocí dvou etalonových multimetrů a proudového bočníku 0,1 V až 1000 V; 20 mA až 200 mA 0,1 mW až 100 kW CMC 0,0065 % 0,1 V až 1000 V; 200 mA až 10 A 0,1 mW až 100 kW CMC 0,0070 % 0,1 V až 1000 V; 10 A až 100 A 0,1 mW až 100 kW CMC 0,013 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9 Moc pradu stalego / watomierze pradu stalego i generatory mocy pradu stalego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar za pomoca dwoch multimetrow wzorcowych i bocznika pradowego 0,1 V do 1000 V; 20 mA do 200 mA od 0,1 mW do 100 kW CMC 0,0065 % 0,1 V do 1000 V; 200 mA do 10 A od 0,1 mW do 100 kW CMC 0,0070 % 0,1 V do 1000 V; 10 A do 100 A od 0,1 mW do 100 kW CMC 0,013 % Stejnosmerny elektricky vykon / stejnosmerne wattmetry a generatory stejnosmerneho vykonu Kalibrace – elektricke veliciny Porovnani nebo mereni pomoci dvou etalonovych multimetru a proudoveho bocniku 0,1 V az 1000 V; 20 mA az 200 mA 0,1 mW az 100 kW CMC 0,0065 % 0,1 V az 1000 V; 200 mA az 10 A 0,1 mW az 100 kW CMC 0,0070 % 0,1 V az 1000 V; 10 A az 100 A 0,1 mW az 100 kW CMC 0,013 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","search_en":"DC power / DC wattmeters and DC power generators Calibration – electrical quantities Comparison or measurement with two standard multimeters and a current shunt 0,1 V to 1000 V; 20 mA to 200 mA 0,1 mW to 100 kW CMC 0,0065 % 0,1 V to 1000 V; 200 mA to 10 A 0,1 mW to 100 kW CMC 0,0070 % 0,1 V to 1000 V; 10 A to 100 A 0,1 mW to 100 kW CMC 0,013 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","search_zh":"直流功率 / 直流功率表和直流功率发生器 校准 – 电学量 用两台标准万用表和电流分流器比较或测量 0,1 V 至 1000 V；20 mA 至 200 mA 0,1 mW 至 100 kW CMC 0,0065 % 0,1 V 至 1000 V；200 mA 至 10 A 0,1 mW 至 100 kW CMC 0,0070 % 0,1 V 至 1000 V；10 A 至 100 A 0,1 mW 至 100 kW CMC 0,013 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"070b17d89180d0ddae57d594","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"6","test_object":"Moc prądu stałego / mierniki cęgowe","test_object_en":"DC power / clamp testers","test_object_zh":"直流功率 / 钳形仪表","test_object_cs":"Stejnosměrný elektrický výkon / klešťové přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"0,1 V do 1000 V; 0,1 A do 1000 A","range":"od 0,01 W do 1000 kW","cmc":"0,36 %"}],"parameters_en":[{"name":"0,1 V to 1000 V; 0,1 A to 1000 A","range":"0,01 W to 1000 kW","cmc":"0,36 %"}],"parameters_zh":[{"name":"0,1 V 至 1000 V；0,1 A 至 1000 A","range":"0,01 W 至 1000 kW","cmc":"0,36 %"}],"parameters_cs":[{"name":"0,1 V až 1000 V; 0,1 A až 1000 A","range":"0,01 W až 1000 kW","cmc":"0,36 %"}],"technique":"Pomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową","technique_en":"Measurement of power simulated by a standard calibrator with current coil","technique_zh":"测量由带电流线圈的标准校准器模拟的功率","technique_cs":"Měření výkonu simulovaného etalonovým kalibrátorem s proudovou cívkou","techniques":["Pomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową"],"techniques_en":["Measurement of power simulated by a standard calibrator with current coil"],"techniques_zh":["测量由带电流线圈的标准校准器模拟的功率"],"techniques_cs":["Měření výkonu simulovaného etalonovým kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n0,1 V do 1000 V; 0,1 A do 1000 A od 0,01 W do 1000 kW CMC 0,36 %\nPomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową","reference":"92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","norm_bases":["92/75-17-5","92/75-17-6","92/75-17-7","92/75-17-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu stałego / mierniki cęgowe Wzorcowanie – wielkości elektryczne Pomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową 0,1 V do 1000 V; 0,1 A do 1000 A od 0,01 W do 1000 kW CMC 0,36 % Stejnosměrný elektrický výkon / klešťové přístroje Kalibrace – elektrické veličiny Měření výkonu simulovaného etalonovým kalibrátorem s proudovou cívkou 0,1 V až 1000 V; 0,1 A až 1000 A 0,01 W až 1000 kW CMC 0,36 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9 Moc pradu stalego / mierniki cegowe Wzorcowanie – wielkosci elektryczne Pomiar mocy symulowanej kalibratorem wzorcowym z cewka pradowa 0,1 V do 1000 V; 0,1 A do 1000 A od 0,01 W do 1000 kW CMC 0,36 % Stejnosmerny elektricky vykon / klestove pristroje Kalibrace – elektricke veliciny Mereni vykonu simulovaneho etalonovym kalibratorem s proudovou civkou 0,1 V az 1000 V; 0,1 A az 1000 A 0,01 W az 1000 kW CMC 0,36 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","search_en":"DC power / clamp testers Calibration – electrical quantities Measurement of power simulated by a standard calibrator with current coil 0,1 V to 1000 V; 0,1 A to 1000 A 0,01 W to 1000 kW CMC 0,36 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","search_zh":"直流功率 / 钳形仪表 校准 – 电学量 测量由带电流线圈的标准校准器模拟的功率 0,1 V 至 1000 V；0,1 A 至 1000 A 0,01 W 至 1000 kW CMC 0,36 % 92/75-17-5, 92/75-17-6, 92/75-17-7, 92/75-17-9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ade7617f4a6b8df2afd67097","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu przemiennego (50 Hz lub 60 Hz; współczynnik mocy 0,5 do 1,0 indukcyjny) / watomierze prądu przemiennego i generatory mocy prądu przemiennego","test_object_en":"AC power (50 Hz or 60 Hz; power factor 0.5 to 1.0 inductive) / AC wattmeters and AC power generators","test_object_zh":"交流功率（50 Hz 或 60 Hz；功率因数 0,5 至 1,0 感性）/ 交流功率表和交流功率发生器","test_object_cs":"Střídavý elektrický výkon (50 Hz nebo 60 Hz; účiník 0,5 až 1,0 induktivní) / střídavé wattmetry a generátory střídavého výkonu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 V do 60 V; 20 mA do 10 A","range":"od 0,1 W do 12 kW","cmc":"0,8 mW/VA"},{"name":"10 V do 60 V; 10 A do 20 A","range":"od 0,1 W do 12 kW","cmc":"1,3 mW/VA"},{"name":"60 V do 450 V; 20 mA do 10 A","range":"od 0,1 W do 12 kW","cmc":"0,7 mW/VA"},{"name":"60 V do 450 V; 10 A do 20 A","range":"od 0,1 W do 12 kW","cmc":"1,2 mW/VA"},{"name":"450 V do 600 V; 20 mA do 10 A","range":"od 0,1 W do 12 kW","cmc":"0,94 mW/VA"},{"name":"450 V do 600 V; 10 A do 20 A","range":"od 0,1 W do 12 kW","cmc":"1,7 mW/VA"}],"parameters_en":[{"name":"10 V to 60 V; 20 mA to 10 A","range":"0,1 W to 12 kW","cmc":"0,8 mW/VA"},{"name":"10 V to 60 V; 10 A to 20 A","range":"0,1 W to 12 kW","cmc":"1,3 mW/VA"},{"name":"60 V to 450 V; 20 mA to 10 A","range":"0,1 W to 12 kW","cmc":"0,7 mW/VA"},{"name":"60 V to 450 V; 10 A to 20 A","range":"0,1 W to 12 kW","cmc":"1,2 mW/VA"},{"name":"450 V to 600 V; 20 mA to 10 A","range":"0,1 W to 12 kW","cmc":"0,94 mW/VA"},{"name":"450 V to 600 V; 10 A to 20 A","range":"0,1 W to 12 kW","cmc":"1,7 mW/VA"}],"parameters_zh":[{"name":"10 V 至 60 V；20 mA 至 10 A","range":"0,1 W 至 12 kW","cmc":"0,8 mW/VA"},{"name":"10 V 至 60 V；10 A 至 20 A","range":"0,1 W 至 12 kW","cmc":"1,3 mW/VA"},{"name":"60 V 至 450 V；20 mA 至 10 A","range":"0,1 W 至 12 kW","cmc":"0,7 mW/VA"},{"name":"60 V 至 450 V；10 A 至 20 A","range":"0,1 W 至 12 kW","cmc":"1,2 mW/VA"},{"name":"450 V 至 600 V；20 mA 至 10 A","range":"0,1 W 至 12 kW","cmc":"0,94 mW/VA"},{"name":"450 V 至 600 V；10 A 至 20 A","range":"0,1 W 至 12 kW","cmc":"1,7 mW/VA"}],"parameters_cs":[{"name":"10 V až 60 V; 20 mA až 10 A","range":"0,1 W až 12 kW","cmc":"0,8 mW/VA"},{"name":"10 V až 60 V; 10 A až 20 A","range":"0,1 W až 12 kW","cmc":"1,3 mW/VA"},{"name":"60 V až 450 V; 20 mA až 10 A","range":"0,1 W až 12 kW","cmc":"0,7 mW/VA"},{"name":"60 V až 450 V; 10 A až 20 A","range":"0,1 W až 12 kW","cmc":"1,2 mW/VA"},{"name":"450 V až 600 V; 20 mA až 10 A","range":"0,1 W až 12 kW","cmc":"0,94 mW/VA"},{"name":"450 V až 600 V; 10 A až 20 A","range":"0,1 W až 12 kW","cmc":"1,7 mW/VA"}],"technique":"Porównanie lub pomiar bezpośredni za pomocą watomierza wzorcowego","technique_en":"Comparison or direct measurement with a standard wattmeter","technique_zh":"与标准功率表比较或用其直接测量","technique_cs":"Porovnání nebo přímé měření pomocí etalonového wattmetru","techniques":["Porównanie lub pomiar bezpośredni za pomocą watomierza wzorcowego"],"techniques_en":["Comparison or direct measurement with a standard wattmeter"],"techniques_zh":["与标准功率表比较或用其直接测量"],"techniques_cs":["Porovnání nebo přímé měření pomocí etalonového wattmetru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n10 V do 60 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,8 mW/VA\n10 V do 60 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,3 mW/VA\n60 V do 450 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,7 mW/VA\n60 V do 450 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,2 mW/VA\n450 V do 600 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,94 mW/VA\n450 V do 600 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,7 mW/VA\nPorównanie lub pomiar bezpośredni za pomocą watomierza wzorcowego","reference":"92/75-17-6, 92/75-17-8","norm_bases":["92/75-17-6","92/75-17-8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu przemiennego (50 Hz lub 60 Hz; współczynnik mocy 0,5 do 1,0 indukcyjny) / watomierze prądu przemiennego i generatory mocy prądu przemiennego Wzorcowanie – wielkości elektryczne Porównanie lub pomiar bezpośredni za pomocą watomierza wzorcowego 10 V do 60 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,8 mW/VA 10 V do 60 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,3 mW/VA 60 V do 450 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,7 mW/VA 60 V do 450 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,2 mW/VA 450 V do 600 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,94 mW/VA 450 V do 600 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,7 mW/VA Střídavý elektrický výkon (50 Hz nebo 60 Hz; účiník 0,5 až 1,0 induktivní) / střídavé wattmetry a generátory střídavého výkonu Kalibrace – elektrické veličiny Porovnání nebo přímé měření pomocí etalonového wattmetru 10 V až 60 V; 20 mA až 10 A 0,1 W až 12 kW CMC 0,8 mW/VA 10 V až 60 V; 10 A až 20 A 0,1 W až 12 kW CMC 1,3 mW/VA 60 V až 450 V; 20 mA až 10 A 0,1 W až 12 kW CMC 0,7 mW/VA 60 V až 450 V; 10 A až 20 A 0,1 W až 12 kW CMC 1,2 mW/VA 450 V až 600 V; 20 mA až 10 A 0,1 W až 12 kW CMC 0,94 mW/VA 450 V až 600 V; 10 A až 20 A 0,1 W až 12 kW CMC 1,7 mW/VA 92/75-17-6, 92/75-17-8 Moc pradu przemiennego (50 Hz lub 60 Hz; wspolczynnik mocy 0,5 do 1,0 indukcyjny) / watomierze pradu przemiennego i generatory mocy pradu przemiennego Wzorcowanie – wielkosci elektryczne Porownanie lub pomiar bezposredni za pomoca watomierza wzorcowego 10 V do 60 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,8 mW/VA 10 V do 60 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,3 mW/VA 60 V do 450 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,7 mW/VA 60 V do 450 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,2 mW/VA 450 V do 600 V; 20 mA do 10 A od 0,1 W do 12 kW CMC 0,94 mW/VA 450 V do 600 V; 10 A do 20 A od 0,1 W do 12 kW CMC 1,7 mW/VA Stridavy elektricky vykon (50 Hz nebo 60 Hz; ucinik 0,5 az 1,0 induktivni) / stridave wattmetry a generatory stridaveho vykonu Kalibrace – elektricke veliciny Porovnani nebo prime mereni pomoci etalonoveho wattmetru 10 V az 60 V; 20 mA az 10 A 0,1 W az 12 kW CMC 0,8 mW/VA 10 V az 60 V; 10 A az 20 A 0,1 W az 12 kW CMC 1,3 mW/VA 60 V az 450 V; 20 mA az 10 A 0,1 W az 12 kW CMC 0,7 mW/VA 60 V az 450 V; 10 A az 20 A 0,1 W az 12 kW CMC 1,2 mW/VA 450 V az 600 V; 20 mA az 10 A 0,1 W az 12 kW CMC 0,94 mW/VA 450 V az 600 V; 10 A az 20 A 0,1 W az 12 kW CMC 1,7 mW/VA 92/75-17-6, 92/75-17-8","search_en":"AC power (50 Hz or 60 Hz; power factor 0.5 to 1.0 inductive) / AC wattmeters and AC power generators Calibration – electrical quantities Comparison or direct measurement with a standard wattmeter 10 V to 60 V; 20 mA to 10 A 0,1 W to 12 kW CMC 0,8 mW/VA 10 V to 60 V; 10 A to 20 A 0,1 W to 12 kW CMC 1,3 mW/VA 60 V to 450 V; 20 mA to 10 A 0,1 W to 12 kW CMC 0,7 mW/VA 60 V to 450 V; 10 A to 20 A 0,1 W to 12 kW CMC 1,2 mW/VA 450 V to 600 V; 20 mA to 10 A 0,1 W to 12 kW CMC 0,94 mW/VA 450 V to 600 V; 10 A to 20 A 0,1 W to 12 kW CMC 1,7 mW/VA 92/75-17-6, 92/75-17-8","search_zh":"交流功率（50 Hz 或 60 Hz；功率因数 0,5 至 1,0 感性）/ 交流功率表和交流功率发生器 校准 – 电学量 与标准功率表比较或用其直接测量 10 V 至 60 V；20 mA 至 10 A 0,1 W 至 12 kW CMC 0,8 mW/VA 10 V 至 60 V；10 A 至 20 A 0,1 W 至 12 kW CMC 1,3 mW/VA 60 V 至 450 V；20 mA 至 10 A 0,1 W 至 12 kW CMC 0,7 mW/VA 60 V 至 450 V；10 A 至 20 A 0,1 W 至 12 kW CMC 1,2 mW/VA 450 V 至 600 V；20 mA 至 10 A 0,1 W 至 12 kW CMC 0,94 mW/VA 450 V 至 600 V；10 A 至 20 A 0,1 W 至 12 kW CMC 1,7 mW/VA 92/75-17-6, 92/75-17-8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b68652b7e737bff7e3e9ebf","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"7","test_object":"Moc prądu przemiennego / mierniki cęgowe","test_object_en":"AC power / clamp testers","test_object_zh":"交流功率 / 钳形仪表","test_object_cs":"Střídavý elektrický výkon / klešťové přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"10 V do 600 V; 0,1 A do 1000 A","range":"od 0,5 W do 600 kW","cmc":"5,8 mW/VA"}],"parameters_en":[{"name":"10 V to 600 V; 0,1 A to 1000 A","range":"0,5 W to 600 kW","cmc":"5,8 mW/VA"}],"parameters_zh":[{"name":"10 V 至 600 V；0,1 A 至 1000 A","range":"0,5 W 至 600 kW","cmc":"5,8 mW/VA"}],"parameters_cs":[{"name":"10 V až 600 V; 0,1 A až 1000 A","range":"0,5 W až 600 kW","cmc":"5,8 mW/VA"}],"technique":"Pomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową","technique_en":"Measurement of power simulated by a standard calibrator with current coil","technique_zh":"测量由带电流线圈的标准校准器模拟的功率","technique_cs":"Měření výkonu simulovaného etalonovým kalibrátorem s proudovou cívkou","techniques":["Pomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową"],"techniques_en":["Measurement of power simulated by a standard calibrator with current coil"],"techniques_zh":["测量由带电流线圈的标准校准器模拟的功率"],"techniques_cs":["Měření výkonu simulovaného etalonovým kalibrátorem s proudovou cívkou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n10 V do 600 V; 0,1 A do 1000 A od 0,5 W do 600 kW CMC 5,8 mW/VA\nPomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową","reference":"92/75-17-6, 92/75-17-8","norm_bases":["92/75-17-6","92/75-17-8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc prądu przemiennego / mierniki cęgowe Wzorcowanie – wielkości elektryczne Pomiar mocy symulowanej kalibratorem wzorcowym z cewką prądową 10 V do 600 V; 0,1 A do 1000 A od 0,5 W do 600 kW CMC 5,8 mW/VA Střídavý elektrický výkon / klešťové přístroje Kalibrace – elektrické veličiny Měření výkonu simulovaného etalonovým kalibrátorem s proudovou cívkou 10 V až 600 V; 0,1 A až 1000 A 0,5 W až 600 kW CMC 5,8 mW/VA 92/75-17-6, 92/75-17-8 Moc pradu przemiennego / mierniki cegowe Wzorcowanie – wielkosci elektryczne Pomiar mocy symulowanej kalibratorem wzorcowym z cewka pradowa 10 V do 600 V; 0,1 A do 1000 A od 0,5 W do 600 kW CMC 5,8 mW/VA Stridavy elektricky vykon / klestove pristroje Kalibrace – elektricke veliciny Mereni vykonu simulovaneho etalonovym kalibratorem s proudovou civkou 10 V az 600 V; 0,1 A az 1000 A 0,5 W az 600 kW CMC 5,8 mW/VA 92/75-17-6, 92/75-17-8","search_en":"AC power / clamp testers Calibration – electrical quantities Measurement of power simulated by a standard calibrator with current coil 10 V to 600 V; 0,1 A to 1000 A 0,5 W to 600 kW CMC 5,8 mW/VA 92/75-17-6, 92/75-17-8","search_zh":"交流功率 / 钳形仪表 校准 – 电学量 测量由带电流线圈的标准校准器模拟的功率 10 V 至 600 V；0,1 A 至 1000 A 0,5 W 至 600 kW CMC 5,8 mW/VA 92/75-17-6, 92/75-17-8","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5e22843220926f6f7f21ec10","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / generatory częstotliwości","test_object_en":"Frequency / frequency generators","test_object_zh":"频率 / 频率发生器","test_object_cs":"Frekvence / generátory frekvence","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"1 mV do 10 V","range":"od 10 Hz do 225 MHz","cmc":"0,0014 %"}],"parameters_en":[{"name":"1 mV to 10 V","range":"10 Hz to 225 MHz","cmc":"0,0014 %"}],"parameters_zh":[{"name":"1 mV 至 10 V","range":"10 Hz 至 225 MHz","cmc":"0,0014 %"}],"parameters_cs":[{"name":"1 mV až 10 V","range":"10 Hz až 225 MHz","cmc":"0,0014 %"}],"technique":"Pomiar bezpośredni licznikiem wzorcowym","technique_en":"Direct measurement by a standard counter","technique_zh":"用标准计数器直接测量","technique_cs":"Přímé měření etalonovým čítačem","techniques":["Pomiar bezpośredni licznikiem wzorcowym"],"techniques_en":["Direct measurement by a standard counter"],"techniques_zh":["用标准计数器直接测量"],"techniques_cs":["Přímé měření etalonovým čítačem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\n1 mV do 10 V od 10 Hz do 225 MHz CMC 0,0014 %\nPomiar bezpośredni licznikiem wzorcowym","reference":"92/75-17-6","norm_bases":["92/75-17-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / generatory częstotliwości Wzorcowanie – wielkości czasu i częstotliwości Pomiar bezpośredni licznikiem wzorcowym 1 mV do 10 V od 10 Hz do 225 MHz CMC 0,0014 % Frekvence / generátory frekvence Kalibrace – veličiny času a frekvence Přímé měření etalonovým čítačem 1 mV až 10 V 10 Hz až 225 MHz CMC 0,0014 % 92/75-17-6 Czestotliwosc / generatory czestotliwosci Wzorcowanie – wielkosci czasu i czestotliwosci Pomiar bezposredni licznikiem wzorcowym 1 mV do 10 V od 10 Hz do 225 MHz CMC 0,0014 % Frekvence / generatory frekvence Kalibrace – veliciny casu a frekvence Prime mereni etalonovym citacem 1 mV az 10 V 10 Hz az 225 MHz CMC 0,0014 % 92/75-17-6","search_en":"Frequency / frequency generators Calibration – time and frequency quantities Direct measurement by a standard counter 1 mV to 10 V 10 Hz to 225 MHz CMC 0,0014 % 92/75-17-6","search_zh":"频率 / 频率发生器 校准 – 时间和频率量 用标准计数器直接测量 1 mV 至 10 V 10 Hz 至 225 MHz CMC 0,0014 % 92/75-17-6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9414753e992b15bafd5915ad","lab_id":"6ade8b2bff068247617080ff","country":"CZ","accr_number":"2254","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / mierniki częstotliwości","test_object_en":"Frequency / frequency meters","test_object_zh":"频率 / 频率测量仪器","test_object_cs":"Frekvence / měřidla frekvence","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"1 mV do 10 V","range":"od 1 Hz do 10 MHz","cmc":"0,0050 %"}],"parameters_en":[{"name":"1 mV to 10 V","range":"1 Hz to 10 MHz","cmc":"0,0050 %"}],"parameters_zh":[{"name":"1 mV 至 10 V","range":"1 Hz 至 10 MHz","cmc":"0,0050 %"}],"parameters_cs":[{"name":"1 mV až 10 V","range":"1 Hz až 10 MHz","cmc":"0,0050 %"}],"technique":"Generowanie kalibratorem","technique_en":"Generation with calibrator","technique_zh":"用校准器产生","technique_cs":"Generování kalibrátorem","techniques":["Generowanie kalibratorem"],"techniques_en":["Generation with calibrator"],"techniques_zh":["用校准器产生"],"techniques_cs":["Generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\n1 mV do 10 V od 1 Hz do 10 MHz CMC 0,0050 %\nGenerowanie kalibratorem","reference":"92/75-17-6","norm_bases":["92/75-17-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / mierniki częstotliwości Wzorcowanie – wielkości czasu i częstotliwości Generowanie kalibratorem 1 mV do 10 V od 1 Hz do 10 MHz CMC 0,0050 % Frekvence / měřidla frekvence Kalibrace – veličiny času a frekvence Generování kalibrátorem 1 mV až 10 V 1 Hz až 10 MHz CMC 0,0050 % 92/75-17-6 Czestotliwosc / mierniki czestotliwosci Wzorcowanie – wielkosci czasu i czestotliwosci Generowanie kalibratorem 1 mV do 10 V od 1 Hz do 10 MHz CMC 0,0050 % Frekvence / meridla frekvence Kalibrace – veliciny casu a frekvence Generovani kalibratorem 1 mV az 10 V 1 Hz az 10 MHz CMC 0,0050 % 92/75-17-6","search_en":"Frequency / frequency meters Calibration – time and frequency quantities Generation with calibrator 1 mV to 10 V 1 Hz to 10 MHz CMC 0,0050 % 92/75-17-6","search_zh":"频率 / 频率测量仪器 校准 – 时间和频率量 用校准器产生 1 mV 至 10 V 1 Hz 至 10 MHz CMC 0,0050 % 92/75-17-6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}