ČEZ, a. s. is a calibration laboratory accredited by ČIA under number 2245.2 (Temelín, Czech Republic). Its accreditation scope covers 18 calibration items in the following areas: Metrology & calibration. Calibrated items include: Meters of ambient and personal dosimetric quantities – air kerma, Meters of ambient and personal dosimetric quantities – air kerma rate, Meters of ambient and personal dosimetric quantities – ambient dose…, Meters of ambient and personal dosimetric quantities – ambient dose…. Most frequently used calibration principles: Measurement on the OG8 irradiator, Measurement using area sources of ionising radiation (IZ).

At a glance

  • Accreditation number: ČIA 2245.2
  • Calibration items in scope: 18
  • Types of calibrated items: 9
  • Calibration principles used: 2
  • City: Temelín, Czech Republic
  • Valid until: 26-01-2028
Accreditation number
2245.2
Accreditation body
ČIA
Address
Jaderná elektrárna Temelín, 373 05 Temelín
City
Temelín, Czech Republic
Division
Metrologia promieniowania jonizującego
Valid until
26-01-2028

What this laboratory calibrates (9)

Calibration principles (2)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
11.06.2024

Accreditation scope — calibration items (18)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Ionising Radiation Metrology EDU
1 Meters of ambient and personal dosimetric quantities – air kerma rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 3,5.10⁻⁷ Gy/h to 2,6.10⁻⁵ Gy/h · CMC 4,9 % OG-8 position: 2 — 1,1.10⁻⁵ Gy/h to 9,0.10⁻⁴ Gy/h · CMC 3,6 % OG-8 position: 3 — 3,0.10⁻⁴ Gy/h to 2,5.10⁻² Gy/h · CMC 3,1 % OG-8 position: 4 — 5,5.10⁻³ Gy/h to 4,3.10⁻¹ Gy/h · CMC 2,4 % OG-8 position: 5 — 7,8.10⁻² Gy/h to 6,2.10⁰ Gy/h · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
2 Meters of ambient and personal dosimetric quantities – ambient dose equivalent rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 4,0.10⁻⁷ Sv/h to 3,1.10⁻⁵ Sv/h · CMC 4,9 % OG-8 position: 2 — 1,3.10⁻⁵ Sv/h to 1,1.10⁻³ Sv/h · CMC 3,6 % OG-8 position: 3 — 3,7.10⁻⁴ Sv/h to 2,9.10⁻² Sv/h · CMC 3,1 % OG-8 position: 4 — 6,6.10⁻³ Sv/h to 5,2.10⁻¹ Sv/h · CMC 2,4 % OG-8 position: 5 — 9,5.10⁻² Sv/h to 7,4.10⁰ Sv/h · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
3 Meters of ambient and personal dosimetric quantities – personal dose equivalent rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 4,0.10⁻⁷ Sv/h to 3,1.10⁻⁵ Sv/h · CMC 4,9 % OG-8 position: 2 — 1,3.10⁻⁵ Sv/h to 1,1.10⁻³ Sv/h · CMC 3,6 % OG-8 position: 3 — 3,7.10⁻⁴ Sv/h to 2,9.10⁻² Sv/h · CMC 3,1 % OG-8 position: 4 — 6,6.10⁻³ Sv/h to 5,2.10⁻¹ Sv/h · CMC 2,4 % OG-8 position: 5 — 9,5.10⁻² Sv/h to 7,4.10⁰ Sv/h · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
4 Meters of ambient and personal dosimetric quantities – photon dose equivalent rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 3,5.10⁻⁷ Sv/h to 3,0.10⁻⁵ Sv/h · CMC 4,9 % OG-8 position: 2 — 1,2.10⁻⁵ Sv/h to 1,0.10⁻³ Sv/h · CMC 3,6 % OG-8 position: 3 — 3,5.10⁻⁴ Sv/h to 2,7.10⁻² Sv/h · CMC 3,1 % OG-8 position: 4 — 6,3.10⁻³ Sv/h to 5,0.10⁻¹ Sv/h · CMC 2,4 % OG-8 position: 5 — 9,0.10⁻² Sv/h to 7,5.10⁰ Sv/h · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
5 Meters of ambient and personal dosimetric quantities – air kerma Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,0.10⁻⁶ Gy to 1,0.10³ Gy · CMC 3,6 % OG-8 position: 3 — 2,5.10⁻⁵ Gy to 1,0.10³ Gy · CMC 3,1 % OG-8 position: 4 — 4,5.10⁻⁴ Gy to 1,0.10³ Gy · CMC 2,4 % OG-8 position: 5 — 6,5.10⁻³ Gy to 1,0.10³ Gy · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
6 Meters of ambient and personal dosimetric quantities – photon dose equivalent Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,1.10⁻⁶ Sv to 1,1.10³ Sv · CMC 3,6 % OG-8 position: 3 — 2,8.10⁻⁵ Sv to 1,1.10³ Sv · CMC 3,1 % OG-8 position: 4 — 5,1.10⁻⁴ Sv to 1,1.10³ Sv · CMC 2,4 % OG-8 position: 5 — 7,4.10⁻³ Sv to 1,1.10³ Sv · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
7 Meters of ambient and personal dosimetric quantities – ambient dose equivalent Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,2.10⁻⁶ Sv to 1,2.10³ Sv · CMC 3,6 % OG-8 position: 3 — 3,0.10⁻⁵ Sv to 1,2.10³ Sv · CMC 3,1 % OG-8 position: 4 — 5,5.10⁻⁴ Sv to 1,2.10³ Sv · CMC 2,4 % OG-8 position: 5 — 7,8.10⁻³ Sv to 1,2.10³ Sv · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
8 Meters of ambient and personal dosimetric quantities – personal dose equivalent Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,2.10⁻⁶ Sv to 1,2.10³ Sv · CMC 3,6 % OG-8 position: 3 — 3,0.10⁻⁵ Sv to 1,2.10³ Sv · CMC 3,1 % OG-8 position: 4 — 5,5.10⁻⁴ Sv to 1,2.10³ Sv · CMC 2,4 % OG-8 position: 5 — 7,8.10⁻³ Sv to 1,2.10³ Sv · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
9 Meters of surface contamination by alpha and beta radionuclides Calibration – atomic and nuclear physics quantities
Surface activity of alpha radionuclides — 1,0.10⁻¹ Bq/cm² to 4,0.10² Bq/cm² · CMC 1,6 % Surface activity of beta radionuclides — 1,0.10⁻¹ Bq/cm² to 35.10³ Bq/cm² · CMC 1,6 % Activity of alpha radionuclides — 2,0.10¹ Bq to 2,0.10⁵ Bq · CMC 1,0 % Activity of beta radionuclides — 4,0.10¹ Bq to 1,0.10⁶ Bq · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement using area sources of ionising radiation (IZ) J61.02.R03.2
Ionising Radiation Metrology ETE
10 Meters of ambient and personal dosimetric quantities – air kerma rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 1,0.10⁻⁷ Gy/h to 3,1.10⁻⁵ Gy/h · CMC 5,7 % OG-8 position: 2 — 3,1.10⁻⁶ Gy/h to 1,2.10⁻³ Gy/h · CMC 2,7 % OG-8 position: 3 — 3,6.10⁻⁴ Gy/h to 1,4.10⁻¹ Gy/h · CMC 2,5 % OG-8 position: 4 — 1,8.10⁻² Gy/h to 7,2.10⁰ Gy/h · CMC 2,1 % OG-8 position: 5 — 3,3.10⁻² Gy/h to 1,3.10¹ Gy/h · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
11 Meters of ambient and personal dosimetric quantities – ambient dose equivalent rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 1,0.10⁻⁷ Sv/h to 3,8.10⁻⁵ Sv/h · CMC 5,7 % OG-8 position: 2 — 3,8.10⁻⁶ Sv/h to 1,5.10⁻³ Sv/h · CMC 2,7 % OG-8 position: 3 — 4,3.10⁻⁴ Sv/h to 1,7.10⁻¹ Sv/h · CMC 2,5 % OG-8 position: 4 — 2,1.10⁻² Sv/h to 8,6.10⁰ Sv/h · CMC 2,1 % OG-8 position: 5 — 4,0.10⁻² Gy/h to 1,6.10¹ Gy/h · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
12 Meters of ambient and personal dosimetric quantities – personal dose equivalent rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 1,0.10⁻⁷ Sv/h to 3,8.10⁻⁵ Sv/h · CMC 5,7 % OG-8 position: 2 — 3,8.10⁻⁶ Sv/h to 1,5.10⁻³ Sv/h · CMC 2,7 % OG-8 position: 3 — 4,3.10⁻⁴ Sv/h to 1,7.10⁻¹ Sv/h · CMC 2,5 % OG-8 position: 4 — 2,1.10⁻² Sv/h to 8,7.10⁰ Sv/h · CMC 2,1 % OG-8 position: 5 — 4,0.10⁻² Gy/h to 1,5.10¹ Gy/h · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
13 Meters of ambient and personal dosimetric quantities – photon dose equivalent rate Calibration – atomic and nuclear physics quantities
OG-8 position: 1 — 1,0.10⁻⁷ Sv/h to 3,6.10⁻⁵ Sv/h · CMC 5,7 % OG-8 position: 2 — 3,6.10⁻⁶ Sv/h to 1,4.10⁻³ Sv/h · CMC 2,7 % OG-8 position: 3 — 4,1.10⁻⁴ Sv/h to 1,6.10⁻¹ Sv/h · CMC 2,5 % OG-8 position: 4 — 2,0.10⁻² Sv/h to 8,2.10⁰ Sv/h · CMC 2,1 % OG-8 position: 5 — 3,7.10⁻² Gy/h to 1,5.10¹ Gy/h · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
14 Meters of ambient and personal dosimetric quantities – air kerma Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,0.10⁻⁶ Gy to 1,0.10³ Gy · CMC 2,7 % OG-8 position: 3 — 3,0.10⁻⁶ Gy to 1,0.10³ Gy · CMC 2,5 % OG-8 position: 4 — 1,5.10⁻⁴ Gy/h to 1,0.10³ Gy · CMC 2,1 % OG-8 position: 5 — 2,8.10⁻⁴ Gy/h to 1,0.10³ Gy · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
15 Meters of ambient and personal dosimetric quantities – photon dose equivalent Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,0.10⁻⁶ Sv to 1,2.10³ Sv · CMC 2,7 % OG-8 position: 3 — 3,6.10⁻⁶ Sv to 1,2.10³ Sv · CMC 2,5 % OG-8 position: 4 — 1,8.10⁻⁴ Sv to 1,2.10³ Sv · CMC 2,1 % OG-8 position: 5 — 3,4.10⁻⁴ Sv to 1,2.10³ Sv · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
16 Meters of ambient and personal dosimetric quantities – ambient dose equivalent Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,0.10⁻⁶ Sv to 1,2.10³ Sv · CMC 2,7 % OG-8 position: 3 — 3,6.10⁻⁶ Sv to 1,2.10³ Sv · CMC 2,5 % OG-8 position: 4 — 1,8.10⁻⁴ Sv to 1,2.10³ Sv · CMC 2,1 % OG-8 position: 5 — 3,4.10⁻⁴ Sv to 1,2.10³ Sv · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
17 Meters of ambient and personal dosimetric quantities – personal dose equivalent Calibration – atomic and nuclear physics quantities
OG-8 position: 2 — 1,0.10⁻⁶ Sv to 1,2.10³ Sv · CMC 2,7 % OG-8 position: 3 — 3,5.10⁻⁶ Sv to 1,2.10³ Sv · CMC 2,5 % OG-8 position: 4 — 1,7.10⁻⁴ Sv to 1,2.10³ Sv · CMC 2,1 % OG-8 position: 5 — 3,1.10⁻⁴ Sv to 1,2.10³ Sv · CMC 1,7 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement on the OG8 irradiator J61.02.R01.2
18 Meters of surface contamination by alpha and beta radionuclides Calibration – atomic and nuclear physics quantities
Surface activity of alpha radionuclides — 1,0.10⁻¹ Bq/cm² to 4,0.10² Bq/cm² · CMC 1,6 % Surface activity of beta radionuclides — 1,0.10⁻¹ Bq/cm² to 35.10³ Bq/cm² · CMC 1,6 % Activity of alpha radionuclides — 2,0.10¹ Bq to 2,0.10⁵ Bq · CMC 1,0 % Activity of beta radionuclides — 4,0.10¹ Bq to 1,0.10⁶ Bq · CMC 2,0 %
CMC for the field of measured quantity: Atomic and nuclear physics quantities
Measurement using area sources of ionising radiation (IZ) J61.02.R03.2

Reference standards (2)

J61.02.R01.2
J61.02.R03.2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/2245.2