{"lab":{"_id":"6ade8b2aff068247617080fd","accr_number":"2245.2","country":"CZ","accr_body":"ČIA","address":"Jaderná elektrárna Temelín, 373 05 Temelín","categories":["metrology"],"city":"Temelín","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.3776769,49.1796639]},"map_coord":[49.1796639,14.3776769],"map_geo":"cai-mapa","methods_count":18,"name":"ČEZ, a. s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinie promieniowania jonizującego.","search_text":"čez, a. s. jaderná elektrárna temelín, 373 05 temelín 2245.2","source_page_url":"https://www.cai.cz/?subjekt=2245-2-cez-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"26-01-2028","website":"www.cez.cz/akliz","certificate_date":"11.06.2024","certificate_no":"280/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinie promieniowania jonizującego.","en":"Calibration in the field of ionising radiation.","zh":"电离辐射领域的校准。","cs":"Kalibrace v oboru ionizujícího záření."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Metrologia promieniowania jonizującego","lab_division_cs":"Metrologie ionizujícího záření","lab_division_en":"Ionising Radiation Metrology","lab_division_zh":"电离辐射计量","lab_locations":[{"code":null,"name":"ČEZ, a. s.","street":"Jaderná elektrárna Temelín","postal_code":"373 05","city":"Temelín","is_hq":true,"address":"Jaderná elektrárna Temelín, 373 05 Temelín","site":"37305|jadernáelektrárnatemelín"},{"code":null,"name":"Metrologia promieniowania jonizującego EDU","street":"Jaderná elektrárna Dukovany","postal_code":"675 50","city":"","is_hq":false,"address":"Jaderná elektrárna Dukovany, 675 50","site":"67550|jadernáelektrárnadukovany"},{"code":null,"name":"Metrologia promieniowania jonizującego ETE","street":"Jaderná elektrárna Temelín","postal_code":"373 05","city":"","is_hq":false,"address":"Jaderná elektrárna Temelín, 373 05","site":"37305|jadernáelektrárnatemelín"}],"lab_locations_en":[{"code":null,"name":"ČEZ, a. s.","street":"Jaderná elektrárna Temelín","postal_code":"373 05","city":"Temelín","is_hq":true,"address":"Jaderná elektrárna Temelín, 373 05 Temelín","site":"37305|jadernáelektrárnatemelín"},{"code":null,"name":"Ionising Radiation Metrology EDU","street":"Jaderná elektrárna Dukovany","postal_code":"675 50","city":"","is_hq":false,"address":"Jaderná elektrárna Dukovany, 675 50","site":"67550|jadernáelektrárnadukovany"},{"code":null,"name":"Ionising Radiation Metrology ETE","street":"Jaderná elektrárna Temelín","postal_code":"373 05","city":"","is_hq":false,"address":"Jaderná elektrárna Temelín, 373 05","site":"37305|jadernáelektrárnatemelín"}],"lab_locations_zh":[{"code":null,"name":"ČEZ, a. s.","street":"Jaderná elektrárna Temelín","postal_code":"373 05","city":"Temelín","is_hq":true,"address":"Jaderná elektrárna Temelín, 373 05 Temelín","site":"37305|jadernáelektrárnatemelín"},{"code":null,"name":"电离辐射计量 EDU","street":"Jaderná elektrárna Dukovany","postal_code":"675 50","city":"","is_hq":false,"address":"Jaderná elektrárna Dukovany, 675 50","site":"67550|jadernáelektrárnadukovany"},{"code":null,"name":"电离辐射计量 ETE","street":"Jaderná elektrárna Temelín","postal_code":"373 05","city":"","is_hq":false,"address":"Jaderná elektrárna Temelín, 373 05","site":"37305|jadernáelektrárnatemelín"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"Pozice OG-8","pl":"Numer wskazuje zamknięte źródło promieniotwórcze w napromienniaczu OG-8.","en":"The number indicates the sealed radionuclide source in the OG-8 irradiator.","zh":"编号表示 OG-8 辐照器中的密封放射源。","cs":"Číslo uvádí uzavřený radionuklidový zdroj v ozařovači OG-8."}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"61efb94f71866e27dd07ba663c0a69e751637e16fe699f95e11158db86a25ed2","source_pdf_url":"https://www.cai.cz/OA/pdf/P280_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"e351d09b332ff004e9d1fb13","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc kermy w powietrzu","test_object_en":"Meters of ambient and personal dosimetric quantities – air kerma rate","test_object_zh":"周围和个人剂量学量测量仪器 – 空气比释动能率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon kermy ve vzduchu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 3,5.10⁻⁷ Gy/h do 2,6.10⁻⁵ Gy/h","cmc":"4,9 %"},{"name":"pozycja OG-8: 2","range":"od 1,1.10⁻⁵ Gy/h do 9,0.10⁻⁴ Gy/h","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 3,0.10⁻⁴ Gy/h do 2,5.10⁻² Gy/h","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 5,5.10⁻³ Gy/h do 4,3.10⁻¹ Gy/h","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 7,8.10⁻² Gy/h do 6,2.10⁰ Gy/h","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"3,5.10⁻⁷ Gy/h to 2,6.10⁻⁵ Gy/h","cmc":"4,9 %"},{"name":"OG-8 position: 2","range":"1,1.10⁻⁵ Gy/h to 9,0.10⁻⁴ Gy/h","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"3,0.10⁻⁴ Gy/h to 2,5.10⁻² Gy/h","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"5,5.10⁻³ Gy/h to 4,3.10⁻¹ Gy/h","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"7,8.10⁻² Gy/h to 6,2.10⁰ Gy/h","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"3,5.10⁻⁷ Gy/h 至 2,6.10⁻⁵ Gy/h","cmc":"4,9 %"},{"name":"OG-8 位置：2","range":"1,1.10⁻⁵ Gy/h 至 9,0.10⁻⁴ Gy/h","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"3,0.10⁻⁴ Gy/h 至 2,5.10⁻² Gy/h","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"5,5.10⁻³ Gy/h 至 4,3.10⁻¹ Gy/h","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"7,8.10⁻² Gy/h 至 6,2.10⁰ Gy/h","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"3,5.10⁻⁷ Gy/h až 2,6.10⁻⁵ Gy/h","cmc":"4,9 %"},{"name":"Pozice OG-8: 2","range":"1,1.10⁻⁵ Gy/h až 9,0.10⁻⁴ Gy/h","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"3,0.10⁻⁴ Gy/h až 2,5.10⁻² Gy/h","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"5,5.10⁻³ Gy/h až 4,3.10⁻¹ Gy/h","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"7,8.10⁻² Gy/h až 6,2.10⁰ Gy/h","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 3,5.10⁻⁷ Gy/h do 2,6.10⁻⁵ Gy/h CMC 4,9 %\npozycja OG-8: 2 od 1,1.10⁻⁵ Gy/h do 9,0.10⁻⁴ Gy/h CMC 3,6 %\npozycja OG-8: 3 od 3,0.10⁻⁴ Gy/h do 2,5.10⁻² Gy/h CMC 3,1 %\npozycja OG-8: 4 od 5,5.10⁻³ Gy/h do 4,3.10⁻¹ Gy/h CMC 2,4 %\npozycja OG-8: 5 od 7,8.10⁻² Gy/h do 6,2.10⁰ Gy/h CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc kermy w powietrzu Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 3,5.10⁻⁷ Gy/h do 2,6.10⁻⁵ Gy/h CMC 4,9 % pozycja OG-8: 2 od 1,1.10⁻⁵ Gy/h do 9,0.10⁻⁴ Gy/h CMC 3,6 % pozycja OG-8: 3 od 3,0.10⁻⁴ Gy/h do 2,5.10⁻² Gy/h CMC 3,1 % pozycja OG-8: 4 od 5,5.10⁻³ Gy/h do 4,3.10⁻¹ Gy/h CMC 2,4 % pozycja OG-8: 5 od 7,8.10⁻² Gy/h do 6,2.10⁰ Gy/h CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon kermy ve vzduchu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 3,5.10⁻⁷ Gy/h až 2,6.10⁻⁵ Gy/h CMC 4,9 % Pozice OG-8: 2 1,1.10⁻⁵ Gy/h až 9,0.10⁻⁴ Gy/h CMC 3,6 % Pozice OG-8: 3 3,0.10⁻⁴ Gy/h až 2,5.10⁻² Gy/h CMC 3,1 % Pozice OG-8: 4 5,5.10⁻³ Gy/h až 4,3.10⁻¹ Gy/h CMC 2,4 % Pozice OG-8: 5 7,8.10⁻² Gy/h až 6,2.10⁰ Gy/h CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc kermy w powietrzu Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 3,5.10⁻⁷ Gy/h do 2,6.10⁻⁵ Gy/h CMC 4,9 % pozycja OG-8: 2 od 1,1.10⁻⁵ Gy/h do 9,0.10⁻⁴ Gy/h CMC 3,6 % pozycja OG-8: 3 od 3,0.10⁻⁴ Gy/h do 2,5.10⁻² Gy/h CMC 3,1 % pozycja OG-8: 4 od 5,5.10⁻³ Gy/h do 4,3.10⁻¹ Gy/h CMC 2,4 % pozycja OG-8: 5 od 7,8.10⁻² Gy/h do 6,2.10⁰ Gy/h CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon kermy ve vzduchu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 3,5.10⁻⁷ Gy/h az 2,6.10⁻⁵ Gy/h CMC 4,9 % Pozice OG-8: 2 1,1.10⁻⁵ Gy/h az 9,0.10⁻⁴ Gy/h CMC 3,6 % Pozice OG-8: 3 3,0.10⁻⁴ Gy/h az 2,5.10⁻² Gy/h CMC 3,1 % Pozice OG-8: 4 5,5.10⁻³ Gy/h az 4,3.10⁻¹ Gy/h CMC 2,4 % Pozice OG-8: 5 7,8.10⁻² Gy/h az 6,2.10⁰ Gy/h CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – air kerma rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 3,5.10⁻⁷ Gy/h to 2,6.10⁻⁵ Gy/h CMC 4,9 % OG-8 position: 2 1,1.10⁻⁵ Gy/h to 9,0.10⁻⁴ Gy/h CMC 3,6 % OG-8 position: 3 3,0.10⁻⁴ Gy/h to 2,5.10⁻² Gy/h CMC 3,1 % OG-8 position: 4 5,5.10⁻³ Gy/h to 4,3.10⁻¹ Gy/h CMC 2,4 % OG-8 position: 5 7,8.10⁻² Gy/h to 6,2.10⁰ Gy/h CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 空气比释动能率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 3,5.10⁻⁷ Gy/h 至 2,6.10⁻⁵ Gy/h CMC 4,9 % OG-8 位置：2 1,1.10⁻⁵ Gy/h 至 9,0.10⁻⁴ Gy/h CMC 3,6 % OG-8 位置：3 3,0.10⁻⁴ Gy/h 至 2,5.10⁻² Gy/h CMC 3,1 % OG-8 位置：4 5,5.10⁻³ Gy/h 至 4,3.10⁻¹ Gy/h CMC 2,4 % OG-8 位置：5 7,8.10⁻² Gy/h 至 6,2.10⁰ Gy/h CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3f1ba2afc62e636070a45cde","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc kermy w powietrzu","test_object_en":"Meters of ambient and personal dosimetric quantities – air kerma rate","test_object_zh":"周围和个人剂量学量测量仪器 – 空气比释动能率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon kermy ve vzduchu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 1,0.10⁻⁷ Gy/h do 3,1.10⁻⁵ Gy/h","cmc":"5,7 %"},{"name":"pozycja OG-8: 2","range":"od 3,1.10⁻⁶ Gy/h do 1,2.10⁻³ Gy/h","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 3,6.10⁻⁴ Gy/h do 1,4.10⁻¹ Gy/h","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 1,8.10⁻² Gy/h do 7,2.10⁰ Gy/h","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 3,3.10⁻² Gy/h do 1,3.10¹ Gy/h","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"1,0.10⁻⁷ Gy/h to 3,1.10⁻⁵ Gy/h","cmc":"5,7 %"},{"name":"OG-8 position: 2","range":"3,1.10⁻⁶ Gy/h to 1,2.10⁻³ Gy/h","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"3,6.10⁻⁴ Gy/h to 1,4.10⁻¹ Gy/h","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"1,8.10⁻² Gy/h to 7,2.10⁰ Gy/h","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"3,3.10⁻² Gy/h to 1,3.10¹ Gy/h","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"1,0.10⁻⁷ Gy/h 至 3,1.10⁻⁵ Gy/h","cmc":"5,7 %"},{"name":"OG-8 位置：2","range":"3,1.10⁻⁶ Gy/h 至 1,2.10⁻³ Gy/h","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"3,6.10⁻⁴ Gy/h 至 1,4.10⁻¹ Gy/h","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"1,8.10⁻² Gy/h 至 7,2.10⁰ Gy/h","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"3,3.10⁻² Gy/h 至 1,3.10¹ Gy/h","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"1,0.10⁻⁷ Gy/h až 3,1.10⁻⁵ Gy/h","cmc":"5,7 %"},{"name":"Pozice OG-8: 2","range":"3,1.10⁻⁶ Gy/h až 1,2.10⁻³ Gy/h","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"3,6.10⁻⁴ Gy/h až 1,4.10⁻¹ Gy/h","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"1,8.10⁻² Gy/h až 7,2.10⁰ Gy/h","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"3,3.10⁻² Gy/h až 1,3.10¹ Gy/h","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 1,0.10⁻⁷ Gy/h do 3,1.10⁻⁵ Gy/h CMC 5,7 %\npozycja OG-8: 2 od 3,1.10⁻⁶ Gy/h do 1,2.10⁻³ Gy/h CMC 2,7 %\npozycja OG-8: 3 od 3,6.10⁻⁴ Gy/h do 1,4.10⁻¹ Gy/h CMC 2,5 %\npozycja OG-8: 4 od 1,8.10⁻² Gy/h do 7,2.10⁰ Gy/h CMC 2,1 %\npozycja OG-8: 5 od 3,3.10⁻² Gy/h do 1,3.10¹ Gy/h CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc kermy w powietrzu Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Gy/h do 3,1.10⁻⁵ Gy/h CMC 5,7 % pozycja OG-8: 2 od 3,1.10⁻⁶ Gy/h do 1,2.10⁻³ Gy/h CMC 2,7 % pozycja OG-8: 3 od 3,6.10⁻⁴ Gy/h do 1,4.10⁻¹ Gy/h CMC 2,5 % pozycja OG-8: 4 od 1,8.10⁻² Gy/h do 7,2.10⁰ Gy/h CMC 2,1 % pozycja OG-8: 5 od 3,3.10⁻² Gy/h do 1,3.10¹ Gy/h CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon kermy ve vzduchu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 1,0.10⁻⁷ Gy/h až 3,1.10⁻⁵ Gy/h CMC 5,7 % Pozice OG-8: 2 3,1.10⁻⁶ Gy/h až 1,2.10⁻³ Gy/h CMC 2,7 % Pozice OG-8: 3 3,6.10⁻⁴ Gy/h až 1,4.10⁻¹ Gy/h CMC 2,5 % Pozice OG-8: 4 1,8.10⁻² Gy/h až 7,2.10⁰ Gy/h CMC 2,1 % Pozice OG-8: 5 3,3.10⁻² Gy/h až 1,3.10¹ Gy/h CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc kermy w powietrzu Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Gy/h do 3,1.10⁻⁵ Gy/h CMC 5,7 % pozycja OG-8: 2 od 3,1.10⁻⁶ Gy/h do 1,2.10⁻³ Gy/h CMC 2,7 % pozycja OG-8: 3 od 3,6.10⁻⁴ Gy/h do 1,4.10⁻¹ Gy/h CMC 2,5 % pozycja OG-8: 4 od 1,8.10⁻² Gy/h do 7,2.10⁰ Gy/h CMC 2,1 % pozycja OG-8: 5 od 3,3.10⁻² Gy/h do 1,3.10¹ Gy/h CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon kermy ve vzduchu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 1,0.10⁻⁷ Gy/h az 3,1.10⁻⁵ Gy/h CMC 5,7 % Pozice OG-8: 2 3,1.10⁻⁶ Gy/h az 1,2.10⁻³ Gy/h CMC 2,7 % Pozice OG-8: 3 3,6.10⁻⁴ Gy/h az 1,4.10⁻¹ Gy/h CMC 2,5 % Pozice OG-8: 4 1,8.10⁻² Gy/h az 7,2.10⁰ Gy/h CMC 2,1 % Pozice OG-8: 5 3,3.10⁻² Gy/h az 1,3.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – air kerma rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 1,0.10⁻⁷ Gy/h to 3,1.10⁻⁵ Gy/h CMC 5,7 % OG-8 position: 2 3,1.10⁻⁶ Gy/h to 1,2.10⁻³ Gy/h CMC 2,7 % OG-8 position: 3 3,6.10⁻⁴ Gy/h to 1,4.10⁻¹ Gy/h CMC 2,5 % OG-8 position: 4 1,8.10⁻² Gy/h to 7,2.10⁰ Gy/h CMC 2,1 % OG-8 position: 5 3,3.10⁻² Gy/h to 1,3.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 空气比释动能率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 1,0.10⁻⁷ Gy/h 至 3,1.10⁻⁵ Gy/h CMC 5,7 % OG-8 位置：2 3,1.10⁻⁶ Gy/h 至 1,2.10⁻³ Gy/h CMC 2,7 % OG-8 位置：3 3,6.10⁻⁴ Gy/h 至 1,4.10⁻¹ Gy/h CMC 2,5 % OG-8 位置：4 1,8.10⁻² Gy/h 至 7,2.10⁰ Gy/h CMC 2,1 % OG-8 位置：5 3,3.10⁻² Gy/h 至 1,3.10¹ Gy/h CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e0ecaedf03b8d1dc8a248b95","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc przestrzennego równoważnika dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent rate","test_object_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon prostorového dávkového ekvivalentu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"pozycja OG-8: 2","range":"od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"4,0.10⁻⁷ Sv/h to 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"OG-8 position: 2","range":"1,3.10⁻⁵ Sv/h to 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"3,7.10⁻⁴ Sv/h to 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"6,6.10⁻³ Sv/h to 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"9,5.10⁻² Sv/h to 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"4,0.10⁻⁷ Sv/h 至 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"OG-8 位置：2","range":"1,3.10⁻⁵ Sv/h 至 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"3,7.10⁻⁴ Sv/h 至 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"6,6.10⁻³ Sv/h 至 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"9,5.10⁻² Sv/h 至 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"4,0.10⁻⁷ Sv/h až 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"Pozice OG-8: 2","range":"1,3.10⁻⁵ Sv/h až 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"3,7.10⁻⁴ Sv/h až 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"6,6.10⁻³ Sv/h až 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"9,5.10⁻² Sv/h až 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h CMC 4,9 %\npozycja OG-8: 2 od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h CMC 3,6 %\npozycja OG-8: 3 od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h CMC 3,1 %\npozycja OG-8: 4 od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h CMC 2,4 %\npozycja OG-8: 5 od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc przestrzennego równoważnika dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h CMC 4,9 % pozycja OG-8: 2 od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h CMC 3,6 % pozycja OG-8: 3 od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h CMC 3,1 % pozycja OG-8: 4 od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h CMC 2,4 % pozycja OG-8: 5 od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon prostorového dávkového ekvivalentu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 4,0.10⁻⁷ Sv/h až 3,1.10⁻⁵ Sv/h CMC 4,9 % Pozice OG-8: 2 1,3.10⁻⁵ Sv/h až 1,1.10⁻³ Sv/h CMC 3,6 % Pozice OG-8: 3 3,7.10⁻⁴ Sv/h až 2,9.10⁻² Sv/h CMC 3,1 % Pozice OG-8: 4 6,6.10⁻³ Sv/h až 5,2.10⁻¹ Sv/h CMC 2,4 % Pozice OG-8: 5 9,5.10⁻² Sv/h až 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc przestrzennego rownowaznika dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h CMC 4,9 % pozycja OG-8: 2 od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h CMC 3,6 % pozycja OG-8: 3 od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h CMC 3,1 % pozycja OG-8: 4 od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h CMC 2,4 % pozycja OG-8: 5 od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon prostoroveho davkoveho ekvivalentu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 4,0.10⁻⁷ Sv/h az 3,1.10⁻⁵ Sv/h CMC 4,9 % Pozice OG-8: 2 1,3.10⁻⁵ Sv/h az 1,1.10⁻³ Sv/h CMC 3,6 % Pozice OG-8: 3 3,7.10⁻⁴ Sv/h az 2,9.10⁻² Sv/h CMC 3,1 % Pozice OG-8: 4 6,6.10⁻³ Sv/h az 5,2.10⁻¹ Sv/h CMC 2,4 % Pozice OG-8: 5 9,5.10⁻² Sv/h az 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 4,0.10⁻⁷ Sv/h to 3,1.10⁻⁵ Sv/h CMC 4,9 % OG-8 position: 2 1,3.10⁻⁵ Sv/h to 1,1.10⁻³ Sv/h CMC 3,6 % OG-8 position: 3 3,7.10⁻⁴ Sv/h to 2,9.10⁻² Sv/h CMC 3,1 % OG-8 position: 4 6,6.10⁻³ Sv/h to 5,2.10⁻¹ Sv/h CMC 2,4 % OG-8 position: 5 9,5.10⁻² Sv/h to 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 4,0.10⁻⁷ Sv/h 至 3,1.10⁻⁵ Sv/h CMC 4,9 % OG-8 位置：2 1,3.10⁻⁵ Sv/h 至 1,1.10⁻³ Sv/h CMC 3,6 % OG-8 位置：3 3,7.10⁻⁴ Sv/h 至 2,9.10⁻² Sv/h CMC 3,1 % OG-8 位置：4 6,6.10⁻³ Sv/h 至 5,2.10⁻¹ Sv/h CMC 2,4 % OG-8 位置：5 9,5.10⁻² Sv/h 至 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc0a9a83ab48f8d3ae7858bc","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc przestrzennego równoważnika dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent rate","test_object_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon prostorového dávkového ekvivalentu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"pozycja OG-8: 2","range":"od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 2,1.10⁻² Sv/h do 8,6.10⁰ Sv/h","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 4,0.10⁻² Gy/h do 1,6.10¹ Gy/h","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"1,0.10⁻⁷ Sv/h to 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"OG-8 position: 2","range":"3,8.10⁻⁶ Sv/h to 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"4,3.10⁻⁴ Sv/h to 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"2,1.10⁻² Sv/h to 8,6.10⁰ Sv/h","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"4,0.10⁻² Gy/h to 1,6.10¹ Gy/h","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"1,0.10⁻⁷ Sv/h 至 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"OG-8 位置：2","range":"3,8.10⁻⁶ Sv/h 至 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"4,3.10⁻⁴ Sv/h 至 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"2,1.10⁻² Sv/h 至 8,6.10⁰ Sv/h","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"4,0.10⁻² Gy/h 至 1,6.10¹ Gy/h","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"1,0.10⁻⁷ Sv/h až 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"Pozice OG-8: 2","range":"3,8.10⁻⁶ Sv/h až 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"4,3.10⁻⁴ Sv/h až 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"2,1.10⁻² Sv/h až 8,6.10⁰ Sv/h","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"4,0.10⁻² Gy/h až 1,6.10¹ Gy/h","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h CMC 5,7 %\npozycja OG-8: 2 od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h CMC 2,7 %\npozycja OG-8: 3 od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h CMC 2,5 %\npozycja OG-8: 4 od 2,1.10⁻² Sv/h do 8,6.10⁰ Sv/h CMC 2,1 %\npozycja OG-8: 5 od 4,0.10⁻² Gy/h do 1,6.10¹ Gy/h CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc przestrzennego równoważnika dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h CMC 5,7 % pozycja OG-8: 2 od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h CMC 2,7 % pozycja OG-8: 3 od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h CMC 2,5 % pozycja OG-8: 4 od 2,1.10⁻² Sv/h do 8,6.10⁰ Sv/h CMC 2,1 % pozycja OG-8: 5 od 4,0.10⁻² Gy/h do 1,6.10¹ Gy/h CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon prostorového dávkového ekvivalentu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 1,0.10⁻⁷ Sv/h až 3,8.10⁻⁵ Sv/h CMC 5,7 % Pozice OG-8: 2 3,8.10⁻⁶ Sv/h až 1,5.10⁻³ Sv/h CMC 2,7 % Pozice OG-8: 3 4,3.10⁻⁴ Sv/h až 1,7.10⁻¹ Sv/h CMC 2,5 % Pozice OG-8: 4 2,1.10⁻² Sv/h až 8,6.10⁰ Sv/h CMC 2,1 % Pozice OG-8: 5 4,0.10⁻² Gy/h až 1,6.10¹ Gy/h CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc przestrzennego rownowaznika dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h CMC 5,7 % pozycja OG-8: 2 od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h CMC 2,7 % pozycja OG-8: 3 od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h CMC 2,5 % pozycja OG-8: 4 od 2,1.10⁻² Sv/h do 8,6.10⁰ Sv/h CMC 2,1 % pozycja OG-8: 5 od 4,0.10⁻² Gy/h do 1,6.10¹ Gy/h CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon prostoroveho davkoveho ekvivalentu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 1,0.10⁻⁷ Sv/h az 3,8.10⁻⁵ Sv/h CMC 5,7 % Pozice OG-8: 2 3,8.10⁻⁶ Sv/h az 1,5.10⁻³ Sv/h CMC 2,7 % Pozice OG-8: 3 4,3.10⁻⁴ Sv/h az 1,7.10⁻¹ Sv/h CMC 2,5 % Pozice OG-8: 4 2,1.10⁻² Sv/h az 8,6.10⁰ Sv/h CMC 2,1 % Pozice OG-8: 5 4,0.10⁻² Gy/h az 1,6.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 1,0.10⁻⁷ Sv/h to 3,8.10⁻⁵ Sv/h CMC 5,7 % OG-8 position: 2 3,8.10⁻⁶ Sv/h to 1,5.10⁻³ Sv/h CMC 2,7 % OG-8 position: 3 4,3.10⁻⁴ Sv/h to 1,7.10⁻¹ Sv/h CMC 2,5 % OG-8 position: 4 2,1.10⁻² Sv/h to 8,6.10⁰ Sv/h CMC 2,1 % OG-8 position: 5 4,0.10⁻² Gy/h to 1,6.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 1,0.10⁻⁷ Sv/h 至 3,8.10⁻⁵ Sv/h CMC 5,7 % OG-8 位置：2 3,8.10⁻⁶ Sv/h 至 1,5.10⁻³ Sv/h CMC 2,7 % OG-8 位置：3 4,3.10⁻⁴ Sv/h 至 1,7.10⁻¹ Sv/h CMC 2,5 % OG-8 位置：4 2,1.10⁻² Sv/h 至 8,6.10⁰ Sv/h CMC 2,1 % OG-8 位置：5 4,0.10⁻² Gy/h 至 1,6.10¹ Gy/h CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"169a0382ce1f90b35ab64f7e","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc indywidualnego równoważnika dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent rate","test_object_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon osobního dávkového ekvivalentu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"pozycja OG-8: 2","range":"od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"4,0.10⁻⁷ Sv/h to 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"OG-8 position: 2","range":"1,3.10⁻⁵ Sv/h to 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"3,7.10⁻⁴ Sv/h to 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"6,6.10⁻³ Sv/h to 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"9,5.10⁻² Sv/h to 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"4,0.10⁻⁷ Sv/h 至 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"OG-8 位置：2","range":"1,3.10⁻⁵ Sv/h 至 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"3,7.10⁻⁴ Sv/h 至 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"6,6.10⁻³ Sv/h 至 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"9,5.10⁻² Sv/h 至 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"4,0.10⁻⁷ Sv/h až 3,1.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"Pozice OG-8: 2","range":"1,3.10⁻⁵ Sv/h až 1,1.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"3,7.10⁻⁴ Sv/h až 2,9.10⁻² Sv/h","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"6,6.10⁻³ Sv/h až 5,2.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"9,5.10⁻² Sv/h až 7,4.10⁰ Sv/h","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h CMC 4,9 %\npozycja OG-8: 2 od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h CMC 3,6 %\npozycja OG-8: 3 od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h CMC 3,1 %\npozycja OG-8: 4 od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h CMC 2,4 %\npozycja OG-8: 5 od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc indywidualnego równoważnika dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h CMC 4,9 % pozycja OG-8: 2 od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h CMC 3,6 % pozycja OG-8: 3 od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h CMC 3,1 % pozycja OG-8: 4 od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h CMC 2,4 % pozycja OG-8: 5 od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon osobního dávkového ekvivalentu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 4,0.10⁻⁷ Sv/h až 3,1.10⁻⁵ Sv/h CMC 4,9 % Pozice OG-8: 2 1,3.10⁻⁵ Sv/h až 1,1.10⁻³ Sv/h CMC 3,6 % Pozice OG-8: 3 3,7.10⁻⁴ Sv/h až 2,9.10⁻² Sv/h CMC 3,1 % Pozice OG-8: 4 6,6.10⁻³ Sv/h až 5,2.10⁻¹ Sv/h CMC 2,4 % Pozice OG-8: 5 9,5.10⁻² Sv/h až 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc indywidualnego rownowaznika dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 4,0.10⁻⁷ Sv/h do 3,1.10⁻⁵ Sv/h CMC 4,9 % pozycja OG-8: 2 od 1,3.10⁻⁵ Sv/h do 1,1.10⁻³ Sv/h CMC 3,6 % pozycja OG-8: 3 od 3,7.10⁻⁴ Sv/h do 2,9.10⁻² Sv/h CMC 3,1 % pozycja OG-8: 4 od 6,6.10⁻³ Sv/h do 5,2.10⁻¹ Sv/h CMC 2,4 % pozycja OG-8: 5 od 9,5.10⁻² Sv/h do 7,4.10⁰ Sv/h CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon osobniho davkoveho ekvivalentu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 4,0.10⁻⁷ Sv/h az 3,1.10⁻⁵ Sv/h CMC 4,9 % Pozice OG-8: 2 1,3.10⁻⁵ Sv/h az 1,1.10⁻³ Sv/h CMC 3,6 % Pozice OG-8: 3 3,7.10⁻⁴ Sv/h az 2,9.10⁻² Sv/h CMC 3,1 % Pozice OG-8: 4 6,6.10⁻³ Sv/h az 5,2.10⁻¹ Sv/h CMC 2,4 % Pozice OG-8: 5 9,5.10⁻² Sv/h az 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 4,0.10⁻⁷ Sv/h to 3,1.10⁻⁵ Sv/h CMC 4,9 % OG-8 position: 2 1,3.10⁻⁵ Sv/h to 1,1.10⁻³ Sv/h CMC 3,6 % OG-8 position: 3 3,7.10⁻⁴ Sv/h to 2,9.10⁻² Sv/h CMC 3,1 % OG-8 position: 4 6,6.10⁻³ Sv/h to 5,2.10⁻¹ Sv/h CMC 2,4 % OG-8 position: 5 9,5.10⁻² Sv/h to 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 4,0.10⁻⁷ Sv/h 至 3,1.10⁻⁵ Sv/h CMC 4,9 % OG-8 位置：2 1,3.10⁻⁵ Sv/h 至 1,1.10⁻³ Sv/h CMC 3,6 % OG-8 位置：3 3,7.10⁻⁴ Sv/h 至 2,9.10⁻² Sv/h CMC 3,1 % OG-8 位置：4 6,6.10⁻³ Sv/h 至 5,2.10⁻¹ Sv/h CMC 2,4 % OG-8 位置：5 9,5.10⁻² Sv/h 至 7,4.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b072890306dfcaf74e1526d2","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc indywidualnego równoważnika dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent rate","test_object_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon osobního dávkového ekvivalentu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"pozycja OG-8: 2","range":"od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 2,1.10⁻² Sv/h do 8,7.10⁰ Sv/h","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 4,0.10⁻² Gy/h do 1,5.10¹ Gy/h","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"1,0.10⁻⁷ Sv/h to 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"OG-8 position: 2","range":"3,8.10⁻⁶ Sv/h to 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"4,3.10⁻⁴ Sv/h to 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"2,1.10⁻² Sv/h to 8,7.10⁰ Sv/h","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"4,0.10⁻² Gy/h to 1,5.10¹ Gy/h","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"1,0.10⁻⁷ Sv/h 至 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"OG-8 位置：2","range":"3,8.10⁻⁶ Sv/h 至 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"4,3.10⁻⁴ Sv/h 至 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"2,1.10⁻² Sv/h 至 8,7.10⁰ Sv/h","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"4,0.10⁻² Gy/h 至 1,5.10¹ Gy/h","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"1,0.10⁻⁷ Sv/h až 3,8.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"Pozice OG-8: 2","range":"3,8.10⁻⁶ Sv/h až 1,5.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"4,3.10⁻⁴ Sv/h až 1,7.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"2,1.10⁻² Sv/h až 8,7.10⁰ Sv/h","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"4,0.10⁻² Gy/h až 1,5.10¹ Gy/h","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h CMC 5,7 %\npozycja OG-8: 2 od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h CMC 2,7 %\npozycja OG-8: 3 od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h CMC 2,5 %\npozycja OG-8: 4 od 2,1.10⁻² Sv/h do 8,7.10⁰ Sv/h CMC 2,1 %\npozycja OG-8: 5 od 4,0.10⁻² Gy/h do 1,5.10¹ Gy/h CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc indywidualnego równoważnika dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h CMC 5,7 % pozycja OG-8: 2 od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h CMC 2,7 % pozycja OG-8: 3 od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h CMC 2,5 % pozycja OG-8: 4 od 2,1.10⁻² Sv/h do 8,7.10⁰ Sv/h CMC 2,1 % pozycja OG-8: 5 od 4,0.10⁻² Gy/h do 1,5.10¹ Gy/h CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon osobního dávkového ekvivalentu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 1,0.10⁻⁷ Sv/h až 3,8.10⁻⁵ Sv/h CMC 5,7 % Pozice OG-8: 2 3,8.10⁻⁶ Sv/h až 1,5.10⁻³ Sv/h CMC 2,7 % Pozice OG-8: 3 4,3.10⁻⁴ Sv/h až 1,7.10⁻¹ Sv/h CMC 2,5 % Pozice OG-8: 4 2,1.10⁻² Sv/h až 8,7.10⁰ Sv/h CMC 2,1 % Pozice OG-8: 5 4,0.10⁻² Gy/h až 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc indywidualnego rownowaznika dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,8.10⁻⁵ Sv/h CMC 5,7 % pozycja OG-8: 2 od 3,8.10⁻⁶ Sv/h do 1,5.10⁻³ Sv/h CMC 2,7 % pozycja OG-8: 3 od 4,3.10⁻⁴ Sv/h do 1,7.10⁻¹ Sv/h CMC 2,5 % pozycja OG-8: 4 od 2,1.10⁻² Sv/h do 8,7.10⁰ Sv/h CMC 2,1 % pozycja OG-8: 5 od 4,0.10⁻² Gy/h do 1,5.10¹ Gy/h CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon osobniho davkoveho ekvivalentu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 1,0.10⁻⁷ Sv/h az 3,8.10⁻⁵ Sv/h CMC 5,7 % Pozice OG-8: 2 3,8.10⁻⁶ Sv/h az 1,5.10⁻³ Sv/h CMC 2,7 % Pozice OG-8: 3 4,3.10⁻⁴ Sv/h az 1,7.10⁻¹ Sv/h CMC 2,5 % Pozice OG-8: 4 2,1.10⁻² Sv/h az 8,7.10⁰ Sv/h CMC 2,1 % Pozice OG-8: 5 4,0.10⁻² Gy/h az 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 1,0.10⁻⁷ Sv/h to 3,8.10⁻⁵ Sv/h CMC 5,7 % OG-8 position: 2 3,8.10⁻⁶ Sv/h to 1,5.10⁻³ Sv/h CMC 2,7 % OG-8 position: 3 4,3.10⁻⁴ Sv/h to 1,7.10⁻¹ Sv/h CMC 2,5 % OG-8 position: 4 2,1.10⁻² Sv/h to 8,7.10⁰ Sv/h CMC 2,1 % OG-8 position: 5 4,0.10⁻² Gy/h to 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 1,0.10⁻⁷ Sv/h 至 3,8.10⁻⁵ Sv/h CMC 5,7 % OG-8 位置：2 3,8.10⁻⁶ Sv/h 至 1,5.10⁻³ Sv/h CMC 2,7 % OG-8 位置：3 4,3.10⁻⁴ Sv/h 至 1,7.10⁻¹ Sv/h CMC 2,5 % OG-8 位置：4 2,1.10⁻² Sv/h 至 8,7.10⁰ Sv/h CMC 2,1 % OG-8 位置：5 4,0.10⁻² Gy/h 至 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b4ad68d11603e5b489237e05","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc fotonowego równoważnika dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent rate","test_object_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon fotonového dávkového ekvivalentu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 3,5.10⁻⁷ Sv/h do 3,0.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"pozycja OG-8: 2","range":"od 1,2.10⁻⁵ Sv/h do 1,0.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 3,5.10⁻⁴ Sv/h do 2,7.10⁻² Sv/h","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 6,3.10⁻³ Sv/h do 5,0.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 9,0.10⁻² Sv/h do 7,5.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"3,5.10⁻⁷ Sv/h to 3,0.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"OG-8 position: 2","range":"1,2.10⁻⁵ Sv/h to 1,0.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"3,5.10⁻⁴ Sv/h to 2,7.10⁻² Sv/h","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"6,3.10⁻³ Sv/h to 5,0.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"9,0.10⁻² Sv/h to 7,5.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"3,5.10⁻⁷ Sv/h 至 3,0.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"OG-8 位置：2","range":"1,2.10⁻⁵ Sv/h 至 1,0.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"3,5.10⁻⁴ Sv/h 至 2,7.10⁻² Sv/h","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"6,3.10⁻³ Sv/h 至 5,0.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"9,0.10⁻² Sv/h 至 7,5.10⁰ Sv/h","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"3,5.10⁻⁷ Sv/h až 3,0.10⁻⁵ Sv/h","cmc":"4,9 %"},{"name":"Pozice OG-8: 2","range":"1,2.10⁻⁵ Sv/h až 1,0.10⁻³ Sv/h","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"3,5.10⁻⁴ Sv/h až 2,7.10⁻² Sv/h","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"6,3.10⁻³ Sv/h až 5,0.10⁻¹ Sv/h","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"9,0.10⁻² Sv/h až 7,5.10⁰ Sv/h","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 3,5.10⁻⁷ Sv/h do 3,0.10⁻⁵ Sv/h CMC 4,9 %\npozycja OG-8: 2 od 1,2.10⁻⁵ Sv/h do 1,0.10⁻³ Sv/h CMC 3,6 %\npozycja OG-8: 3 od 3,5.10⁻⁴ Sv/h do 2,7.10⁻² Sv/h CMC 3,1 %\npozycja OG-8: 4 od 6,3.10⁻³ Sv/h do 5,0.10⁻¹ Sv/h CMC 2,4 %\npozycja OG-8: 5 od 9,0.10⁻² Sv/h do 7,5.10⁰ Sv/h CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc fotonowego równoważnika dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 3,5.10⁻⁷ Sv/h do 3,0.10⁻⁵ Sv/h CMC 4,9 % pozycja OG-8: 2 od 1,2.10⁻⁵ Sv/h do 1,0.10⁻³ Sv/h CMC 3,6 % pozycja OG-8: 3 od 3,5.10⁻⁴ Sv/h do 2,7.10⁻² Sv/h CMC 3,1 % pozycja OG-8: 4 od 6,3.10⁻³ Sv/h do 5,0.10⁻¹ Sv/h CMC 2,4 % pozycja OG-8: 5 od 9,0.10⁻² Sv/h do 7,5.10⁰ Sv/h CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon fotonového dávkového ekvivalentu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 3,5.10⁻⁷ Sv/h až 3,0.10⁻⁵ Sv/h CMC 4,9 % Pozice OG-8: 2 1,2.10⁻⁵ Sv/h až 1,0.10⁻³ Sv/h CMC 3,6 % Pozice OG-8: 3 3,5.10⁻⁴ Sv/h až 2,7.10⁻² Sv/h CMC 3,1 % Pozice OG-8: 4 6,3.10⁻³ Sv/h až 5,0.10⁻¹ Sv/h CMC 2,4 % Pozice OG-8: 5 9,0.10⁻² Sv/h až 7,5.10⁰ Sv/h CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc fotonowego rownowaznika dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 3,5.10⁻⁷ Sv/h do 3,0.10⁻⁵ Sv/h CMC 4,9 % pozycja OG-8: 2 od 1,2.10⁻⁵ Sv/h do 1,0.10⁻³ Sv/h CMC 3,6 % pozycja OG-8: 3 od 3,5.10⁻⁴ Sv/h do 2,7.10⁻² Sv/h CMC 3,1 % pozycja OG-8: 4 od 6,3.10⁻³ Sv/h do 5,0.10⁻¹ Sv/h CMC 2,4 % pozycja OG-8: 5 od 9,0.10⁻² Sv/h do 7,5.10⁰ Sv/h CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon fotonoveho davkoveho ekvivalentu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 3,5.10⁻⁷ Sv/h az 3,0.10⁻⁵ Sv/h CMC 4,9 % Pozice OG-8: 2 1,2.10⁻⁵ Sv/h az 1,0.10⁻³ Sv/h CMC 3,6 % Pozice OG-8: 3 3,5.10⁻⁴ Sv/h az 2,7.10⁻² Sv/h CMC 3,1 % Pozice OG-8: 4 6,3.10⁻³ Sv/h az 5,0.10⁻¹ Sv/h CMC 2,4 % Pozice OG-8: 5 9,0.10⁻² Sv/h az 7,5.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 3,5.10⁻⁷ Sv/h to 3,0.10⁻⁵ Sv/h CMC 4,9 % OG-8 position: 2 1,2.10⁻⁵ Sv/h to 1,0.10⁻³ Sv/h CMC 3,6 % OG-8 position: 3 3,5.10⁻⁴ Sv/h to 2,7.10⁻² Sv/h CMC 3,1 % OG-8 position: 4 6,3.10⁻³ Sv/h to 5,0.10⁻¹ Sv/h CMC 2,4 % OG-8 position: 5 9,0.10⁻² Sv/h to 7,5.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 3,5.10⁻⁷ Sv/h 至 3,0.10⁻⁵ Sv/h CMC 4,9 % OG-8 位置：2 1,2.10⁻⁵ Sv/h 至 1,0.10⁻³ Sv/h CMC 3,6 % OG-8 位置：3 3,5.10⁻⁴ Sv/h 至 2,7.10⁻² Sv/h CMC 3,1 % OG-8 位置：4 6,3.10⁻³ Sv/h 至 5,0.10⁻¹ Sv/h CMC 2,4 % OG-8 位置：5 9,0.10⁻² Sv/h 至 7,5.10⁰ Sv/h CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4b4b625ed5374bfa89883ad2","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc fotonowego równoważnika dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent rate","test_object_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量率","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon fotonového dávkového ekvivalentu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 1","range":"od 1,0.10⁻⁷ Sv/h do 3,6.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"pozycja OG-8: 2","range":"od 3,6.10⁻⁶ Sv/h do 1,4.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 4,1.10⁻⁴ Sv/h do 1,6.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 2,0.10⁻² Sv/h do 8,2.10⁰ Sv/h","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 3,7.10⁻² Gy/h do 1,5.10¹ Gy/h","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 1","range":"1,0.10⁻⁷ Sv/h to 3,6.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"OG-8 position: 2","range":"3,6.10⁻⁶ Sv/h to 1,4.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"4,1.10⁻⁴ Sv/h to 1,6.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"2,0.10⁻² Sv/h to 8,2.10⁰ Sv/h","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"3,7.10⁻² Gy/h to 1,5.10¹ Gy/h","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：1","range":"1,0.10⁻⁷ Sv/h 至 3,6.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"OG-8 位置：2","range":"3,6.10⁻⁶ Sv/h 至 1,4.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"4,1.10⁻⁴ Sv/h 至 1,6.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"2,0.10⁻² Sv/h 至 8,2.10⁰ Sv/h","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"3,7.10⁻² Gy/h 至 1,5.10¹ Gy/h","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 1","range":"1,0.10⁻⁷ Sv/h až 3,6.10⁻⁵ Sv/h","cmc":"5,7 %"},{"name":"Pozice OG-8: 2","range":"3,6.10⁻⁶ Sv/h až 1,4.10⁻³ Sv/h","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"4,1.10⁻⁴ Sv/h až 1,6.10⁻¹ Sv/h","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"2,0.10⁻² Sv/h až 8,2.10⁰ Sv/h","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"3,7.10⁻² Gy/h až 1,5.10¹ Gy/h","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,6.10⁻⁵ Sv/h CMC 5,7 %\npozycja OG-8: 2 od 3,6.10⁻⁶ Sv/h do 1,4.10⁻³ Sv/h CMC 2,7 %\npozycja OG-8: 3 od 4,1.10⁻⁴ Sv/h do 1,6.10⁻¹ Sv/h CMC 2,5 %\npozycja OG-8: 4 od 2,0.10⁻² Sv/h do 8,2.10⁰ Sv/h CMC 2,1 %\npozycja OG-8: 5 od 3,7.10⁻² Gy/h do 1,5.10¹ Gy/h CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – moc fotonowego równoważnika dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,6.10⁻⁵ Sv/h CMC 5,7 % pozycja OG-8: 2 od 3,6.10⁻⁶ Sv/h do 1,4.10⁻³ Sv/h CMC 2,7 % pozycja OG-8: 3 od 4,1.10⁻⁴ Sv/h do 1,6.10⁻¹ Sv/h CMC 2,5 % pozycja OG-8: 4 od 2,0.10⁻² Sv/h do 8,2.10⁰ Sv/h CMC 2,1 % pozycja OG-8: 5 od 3,7.10⁻² Gy/h do 1,5.10¹ Gy/h CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Příkon fotonového dávkového ekvivalentu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 1 1,0.10⁻⁷ Sv/h až 3,6.10⁻⁵ Sv/h CMC 5,7 % Pozice OG-8: 2 3,6.10⁻⁶ Sv/h až 1,4.10⁻³ Sv/h CMC 2,7 % Pozice OG-8: 3 4,1.10⁻⁴ Sv/h až 1,6.10⁻¹ Sv/h CMC 2,5 % Pozice OG-8: 4 2,0.10⁻² Sv/h až 8,2.10⁰ Sv/h CMC 2,1 % Pozice OG-8: 5 3,7.10⁻² Gy/h až 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – moc fotonowego rownowaznika dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 1 od 1,0.10⁻⁷ Sv/h do 3,6.10⁻⁵ Sv/h CMC 5,7 % pozycja OG-8: 2 od 3,6.10⁻⁶ Sv/h do 1,4.10⁻³ Sv/h CMC 2,7 % pozycja OG-8: 3 od 4,1.10⁻⁴ Sv/h do 1,6.10⁻¹ Sv/h CMC 2,5 % pozycja OG-8: 4 od 2,0.10⁻² Sv/h do 8,2.10⁰ Sv/h CMC 2,1 % pozycja OG-8: 5 od 3,7.10⁻² Gy/h do 1,5.10¹ Gy/h CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prikon fotonoveho davkoveho ekvivalentu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 1 1,0.10⁻⁷ Sv/h az 3,6.10⁻⁵ Sv/h CMC 5,7 % Pozice OG-8: 2 3,6.10⁻⁶ Sv/h az 1,4.10⁻³ Sv/h CMC 2,7 % Pozice OG-8: 3 4,1.10⁻⁴ Sv/h az 1,6.10⁻¹ Sv/h CMC 2,5 % Pozice OG-8: 4 2,0.10⁻² Sv/h az 8,2.10⁰ Sv/h CMC 2,1 % Pozice OG-8: 5 3,7.10⁻² Gy/h az 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent rate Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 1 1,0.10⁻⁷ Sv/h to 3,6.10⁻⁵ Sv/h CMC 5,7 % OG-8 position: 2 3,6.10⁻⁶ Sv/h to 1,4.10⁻³ Sv/h CMC 2,7 % OG-8 position: 3 4,1.10⁻⁴ Sv/h to 1,6.10⁻¹ Sv/h CMC 2,5 % OG-8 position: 4 2,0.10⁻² Sv/h to 8,2.10⁰ Sv/h CMC 2,1 % OG-8 position: 5 3,7.10⁻² Gy/h to 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量率 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：1 1,0.10⁻⁷ Sv/h 至 3,6.10⁻⁵ Sv/h CMC 5,7 % OG-8 位置：2 3,6.10⁻⁶ Sv/h 至 1,4.10⁻³ Sv/h CMC 2,7 % OG-8 位置：3 4,1.10⁻⁴ Sv/h 至 1,6.10⁻¹ Sv/h CMC 2,5 % OG-8 位置：4 2,0.10⁻² Sv/h 至 8,2.10⁰ Sv/h CMC 2,1 % OG-8 位置：5 3,7.10⁻² Gy/h 至 1,5.10¹ Gy/h CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8e42098dd6b63cab90d024a8","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – kerma w powietrzu","test_object_en":"Meters of ambient and personal dosimetric quantities – air kerma","test_object_zh":"周围和个人剂量学量测量仪器 – 空气比释动能","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Kerma ve vzduchu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,0.10⁻⁶ Gy do 1,0.10³ Gy","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 2,5.10⁻⁵ Gy do 1,0.10³ Gy","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 4,5.10⁻⁴ Gy do 1,0.10³ Gy","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 6,5.10⁻³ Gy do 1,0.10³ Gy","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,0.10⁻⁶ Gy to 1,0.10³ Gy","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"2,5.10⁻⁵ Gy to 1,0.10³ Gy","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"4,5.10⁻⁴ Gy to 1,0.10³ Gy","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"6,5.10⁻³ Gy to 1,0.10³ Gy","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,0.10⁻⁶ Gy 至 1,0.10³ Gy","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"2,5.10⁻⁵ Gy 至 1,0.10³ Gy","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"4,5.10⁻⁴ Gy 至 1,0.10³ Gy","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"6,5.10⁻³ Gy 至 1,0.10³ Gy","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,0.10⁻⁶ Gy až 1,0.10³ Gy","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"2,5.10⁻⁵ Gy až 1,0.10³ Gy","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"4,5.10⁻⁴ Gy až 1,0.10³ Gy","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"6,5.10⁻³ Gy až 1,0.10³ Gy","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 3,6 %\npozycja OG-8: 3 od 2,5.10⁻⁵ Gy do 1,0.10³ Gy CMC 3,1 %\npozycja OG-8: 4 od 4,5.10⁻⁴ Gy do 1,0.10³ Gy CMC 2,4 %\npozycja OG-8: 5 od 6,5.10⁻³ Gy do 1,0.10³ Gy CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – kerma w powietrzu Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 3,6 % pozycja OG-8: 3 od 2,5.10⁻⁵ Gy do 1,0.10³ Gy CMC 3,1 % pozycja OG-8: 4 od 4,5.10⁻⁴ Gy do 1,0.10³ Gy CMC 2,4 % pozycja OG-8: 5 od 6,5.10⁻³ Gy do 1,0.10³ Gy CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Kerma ve vzduchu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,0.10⁻⁶ Gy až 1,0.10³ Gy CMC 3,6 % Pozice OG-8: 3 2,5.10⁻⁵ Gy až 1,0.10³ Gy CMC 3,1 % Pozice OG-8: 4 4,5.10⁻⁴ Gy až 1,0.10³ Gy CMC 2,4 % Pozice OG-8: 5 6,5.10⁻³ Gy až 1,0.10³ Gy CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – kerma w powietrzu Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 3,6 % pozycja OG-8: 3 od 2,5.10⁻⁵ Gy do 1,0.10³ Gy CMC 3,1 % pozycja OG-8: 4 od 4,5.10⁻⁴ Gy do 1,0.10³ Gy CMC 2,4 % pozycja OG-8: 5 od 6,5.10⁻³ Gy do 1,0.10³ Gy CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Kerma ve vzduchu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,0.10⁻⁶ Gy az 1,0.10³ Gy CMC 3,6 % Pozice OG-8: 3 2,5.10⁻⁵ Gy az 1,0.10³ Gy CMC 3,1 % Pozice OG-8: 4 4,5.10⁻⁴ Gy az 1,0.10³ Gy CMC 2,4 % Pozice OG-8: 5 6,5.10⁻³ Gy az 1,0.10³ Gy CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – air kerma Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,0.10⁻⁶ Gy to 1,0.10³ Gy CMC 3,6 % OG-8 position: 3 2,5.10⁻⁵ Gy to 1,0.10³ Gy CMC 3,1 % OG-8 position: 4 4,5.10⁻⁴ Gy to 1,0.10³ Gy CMC 2,4 % OG-8 position: 5 6,5.10⁻³ Gy to 1,0.10³ Gy CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 空气比释动能 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,0.10⁻⁶ Gy 至 1,0.10³ Gy CMC 3,6 % OG-8 位置：3 2,5.10⁻⁵ Gy 至 1,0.10³ Gy CMC 3,1 % OG-8 位置：4 4,5.10⁻⁴ Gy 至 1,0.10³ Gy CMC 2,4 % OG-8 位置：5 6,5.10⁻³ Gy 至 1,0.10³ Gy CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"142c83032209f8f236a4c210","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – kerma w powietrzu","test_object_en":"Meters of ambient and personal dosimetric quantities – air kerma","test_object_zh":"周围和个人剂量学量测量仪器 – 空气比释动能","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Kerma ve vzduchu","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,0.10⁻⁶ Gy do 1,0.10³ Gy","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 3,0.10⁻⁶ Gy do 1,0.10³ Gy","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 1,5.10⁻⁴ Gy/h do 1,0.10³ Gy","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 2,8.10⁻⁴ Gy/h do 1,0.10³ Gy","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,0.10⁻⁶ Gy to 1,0.10³ Gy","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"3,0.10⁻⁶ Gy to 1,0.10³ Gy","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"1,5.10⁻⁴ Gy/h to 1,0.10³ Gy","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"2,8.10⁻⁴ Gy/h to 1,0.10³ Gy","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,0.10⁻⁶ Gy 至 1,0.10³ Gy","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"3,0.10⁻⁶ Gy 至 1,0.10³ Gy","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"1,5.10⁻⁴ Gy/h 至 1,0.10³ Gy","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"2,8.10⁻⁴ Gy/h 至 1,0.10³ Gy","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,0.10⁻⁶ Gy až 1,0.10³ Gy","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"3,0.10⁻⁶ Gy až 1,0.10³ Gy","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"1,5.10⁻⁴ Gy/h až 1,0.10³ Gy","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"2,8.10⁻⁴ Gy/h až 1,0.10³ Gy","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 2,7 %\npozycja OG-8: 3 od 3,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 2,5 %\npozycja OG-8: 4 od 1,5.10⁻⁴ Gy/h do 1,0.10³ Gy CMC 2,1 %\npozycja OG-8: 5 od 2,8.10⁻⁴ Gy/h do 1,0.10³ Gy CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – kerma w powietrzu Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 2,7 % pozycja OG-8: 3 od 3,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 2,5 % pozycja OG-8: 4 od 1,5.10⁻⁴ Gy/h do 1,0.10³ Gy CMC 2,1 % pozycja OG-8: 5 od 2,8.10⁻⁴ Gy/h do 1,0.10³ Gy CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Kerma ve vzduchu Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,0.10⁻⁶ Gy až 1,0.10³ Gy CMC 2,7 % Pozice OG-8: 3 3,0.10⁻⁶ Gy až 1,0.10³ Gy CMC 2,5 % Pozice OG-8: 4 1,5.10⁻⁴ Gy/h až 1,0.10³ Gy CMC 2,1 % Pozice OG-8: 5 2,8.10⁻⁴ Gy/h až 1,0.10³ Gy CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – kerma w powietrzu Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 2,7 % pozycja OG-8: 3 od 3,0.10⁻⁶ Gy do 1,0.10³ Gy CMC 2,5 % pozycja OG-8: 4 od 1,5.10⁻⁴ Gy/h do 1,0.10³ Gy CMC 2,1 % pozycja OG-8: 5 od 2,8.10⁻⁴ Gy/h do 1,0.10³ Gy CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Kerma ve vzduchu Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,0.10⁻⁶ Gy az 1,0.10³ Gy CMC 2,7 % Pozice OG-8: 3 3,0.10⁻⁶ Gy az 1,0.10³ Gy CMC 2,5 % Pozice OG-8: 4 1,5.10⁻⁴ Gy/h az 1,0.10³ Gy CMC 2,1 % Pozice OG-8: 5 2,8.10⁻⁴ Gy/h az 1,0.10³ Gy CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – air kerma Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,0.10⁻⁶ Gy to 1,0.10³ Gy CMC 2,7 % OG-8 position: 3 3,0.10⁻⁶ Gy to 1,0.10³ Gy CMC 2,5 % OG-8 position: 4 1,5.10⁻⁴ Gy/h to 1,0.10³ Gy CMC 2,1 % OG-8 position: 5 2,8.10⁻⁴ Gy/h to 1,0.10³ Gy CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 空气比释动能 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,0.10⁻⁶ Gy 至 1,0.10³ Gy CMC 2,7 % OG-8 位置：3 3,0.10⁻⁶ Gy 至 1,0.10³ Gy CMC 2,5 % OG-8 位置：4 1,5.10⁻⁴ Gy/h 至 1,0.10³ Gy CMC 2,1 % OG-8 位置：5 2,8.10⁻⁴ Gy/h 至 1,0.10³ Gy CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"093d8da202a328a5829e5496","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – fotonowy równoważnik dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent","test_object_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Fotonový dávkový ekvivalent","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,1.10⁻⁶ Sv do 1,1.10³ Sv","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 2,8.10⁻⁵ Sv do 1,1.10³ Sv","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 5,1.10⁻⁴ Sv do 1,1.10³ Sv","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 7,4.10⁻³ Sv do 1,1.10³ Sv","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,1.10⁻⁶ Sv to 1,1.10³ Sv","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"2,8.10⁻⁵ Sv to 1,1.10³ Sv","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"5,1.10⁻⁴ Sv to 1,1.10³ Sv","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"7,4.10⁻³ Sv to 1,1.10³ Sv","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,1.10⁻⁶ Sv 至 1,1.10³ Sv","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"2,8.10⁻⁵ Sv 至 1,1.10³ Sv","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"5,1.10⁻⁴ Sv 至 1,1.10³ Sv","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"7,4.10⁻³ Sv 至 1,1.10³ Sv","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,1.10⁻⁶ Sv až 1,1.10³ Sv","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"2,8.10⁻⁵ Sv až 1,1.10³ Sv","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"5,1.10⁻⁴ Sv až 1,1.10³ Sv","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"7,4.10⁻³ Sv až 1,1.10³ Sv","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,1.10⁻⁶ Sv do 1,1.10³ Sv CMC 3,6 %\npozycja OG-8: 3 od 2,8.10⁻⁵ Sv do 1,1.10³ Sv CMC 3,1 %\npozycja OG-8: 4 od 5,1.10⁻⁴ Sv do 1,1.10³ Sv CMC 2,4 %\npozycja OG-8: 5 od 7,4.10⁻³ Sv do 1,1.10³ Sv CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – fotonowy równoważnik dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,1.10⁻⁶ Sv do 1,1.10³ Sv CMC 3,6 % pozycja OG-8: 3 od 2,8.10⁻⁵ Sv do 1,1.10³ Sv CMC 3,1 % pozycja OG-8: 4 od 5,1.10⁻⁴ Sv do 1,1.10³ Sv CMC 2,4 % pozycja OG-8: 5 od 7,4.10⁻³ Sv do 1,1.10³ Sv CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Fotonový dávkový ekvivalent Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,1.10⁻⁶ Sv až 1,1.10³ Sv CMC 3,6 % Pozice OG-8: 3 2,8.10⁻⁵ Sv až 1,1.10³ Sv CMC 3,1 % Pozice OG-8: 4 5,1.10⁻⁴ Sv až 1,1.10³ Sv CMC 2,4 % Pozice OG-8: 5 7,4.10⁻³ Sv až 1,1.10³ Sv CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – fotonowy rownowaznik dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,1.10⁻⁶ Sv do 1,1.10³ Sv CMC 3,6 % pozycja OG-8: 3 od 2,8.10⁻⁵ Sv do 1,1.10³ Sv CMC 3,1 % pozycja OG-8: 4 od 5,1.10⁻⁴ Sv do 1,1.10³ Sv CMC 2,4 % pozycja OG-8: 5 od 7,4.10⁻³ Sv do 1,1.10³ Sv CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Fotonovy davkovy ekvivalent Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,1.10⁻⁶ Sv az 1,1.10³ Sv CMC 3,6 % Pozice OG-8: 3 2,8.10⁻⁵ Sv az 1,1.10³ Sv CMC 3,1 % Pozice OG-8: 4 5,1.10⁻⁴ Sv az 1,1.10³ Sv CMC 2,4 % Pozice OG-8: 5 7,4.10⁻³ Sv az 1,1.10³ Sv CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,1.10⁻⁶ Sv to 1,1.10³ Sv CMC 3,6 % OG-8 position: 3 2,8.10⁻⁵ Sv to 1,1.10³ Sv CMC 3,1 % OG-8 position: 4 5,1.10⁻⁴ Sv to 1,1.10³ Sv CMC 2,4 % OG-8 position: 5 7,4.10⁻³ Sv to 1,1.10³ Sv CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,1.10⁻⁶ Sv 至 1,1.10³ Sv CMC 3,6 % OG-8 位置：3 2,8.10⁻⁵ Sv 至 1,1.10³ Sv CMC 3,1 % OG-8 位置：4 5,1.10⁻⁴ Sv 至 1,1.10³ Sv CMC 2,4 % OG-8 位置：5 7,4.10⁻³ Sv 至 1,1.10³ Sv CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b77fb4b2a1d2ad2a72ec06d7","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – fotonowy równoważnik dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent","test_object_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Fotonový dávkový ekvivalent","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,0.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 3,6.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 1,8.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 3,4.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,0.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"3,6.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"1,8.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"3,4.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,0.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"3,6.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"1,8.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"3,4.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,0.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"3,6.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"1,8.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"3,4.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 %\npozycja OG-8: 3 od 3,6.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 %\npozycja OG-8: 4 od 1,8.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 %\npozycja OG-8: 5 od 3,4.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – fotonowy równoważnik dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 % pozycja OG-8: 3 od 3,6.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 % pozycja OG-8: 4 od 1,8.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 % pozycja OG-8: 5 od 3,4.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Fotonový dávkový ekvivalent Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,0.10⁻⁶ Sv až 1,2.10³ Sv CMC 2,7 % Pozice OG-8: 3 3,6.10⁻⁶ Sv až 1,2.10³ Sv CMC 2,5 % Pozice OG-8: 4 1,8.10⁻⁴ Sv až 1,2.10³ Sv CMC 2,1 % Pozice OG-8: 5 3,4.10⁻⁴ Sv až 1,2.10³ Sv CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – fotonowy rownowaznik dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 % pozycja OG-8: 3 od 3,6.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 % pozycja OG-8: 4 od 1,8.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 % pozycja OG-8: 5 od 3,4.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Fotonovy davkovy ekvivalent Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,0.10⁻⁶ Sv az 1,2.10³ Sv CMC 2,7 % Pozice OG-8: 3 3,6.10⁻⁶ Sv az 1,2.10³ Sv CMC 2,5 % Pozice OG-8: 4 1,8.10⁻⁴ Sv az 1,2.10³ Sv CMC 2,1 % Pozice OG-8: 5 3,4.10⁻⁴ Sv az 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – photon dose equivalent Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,0.10⁻⁶ Sv to 1,2.10³ Sv CMC 2,7 % OG-8 position: 3 3,6.10⁻⁶ Sv to 1,2.10³ Sv CMC 2,5 % OG-8 position: 4 1,8.10⁻⁴ Sv to 1,2.10³ Sv CMC 2,1 % OG-8 position: 5 3,4.10⁻⁴ Sv to 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 光子剂量当量 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,0.10⁻⁶ Sv 至 1,2.10³ Sv CMC 2,7 % OG-8 位置：3 3,6.10⁻⁶ Sv 至 1,2.10³ Sv CMC 2,5 % OG-8 位置：4 1,8.10⁻⁴ Sv 至 1,2.10³ Sv CMC 2,1 % OG-8 位置：5 3,4.10⁻⁴ Sv 至 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"30908a6d802da5cb7f8d33e8","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – przestrzenny równoważnik dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent","test_object_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Prostorový dávkový ekvivalent","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,2.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 3,0.10⁻⁵ Sv do 1,2.10³ Sv","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 5,5.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 7,8.10⁻³ Sv do 1,2.10³ Sv","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,2.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"3,0.10⁻⁵ Sv to 1,2.10³ Sv","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"5,5.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"7,8.10⁻³ Sv to 1,2.10³ Sv","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,2.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"3,0.10⁻⁵ Sv 至 1,2.10³ Sv","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"5,5.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"7,8.10⁻³ Sv 至 1,2.10³ Sv","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,2.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"3,0.10⁻⁵ Sv až 1,2.10³ Sv","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"5,5.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"7,8.10⁻³ Sv až 1,2.10³ Sv","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,2.10⁻⁶ Sv do 1,2.10³ Sv CMC 3,6 %\npozycja OG-8: 3 od 3,0.10⁻⁵ Sv do 1,2.10³ Sv CMC 3,1 %\npozycja OG-8: 4 od 5,5.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,4 %\npozycja OG-8: 5 od 7,8.10⁻³ Sv do 1,2.10³ Sv CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – przestrzenny równoważnik dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,2.10⁻⁶ Sv do 1,2.10³ Sv CMC 3,6 % pozycja OG-8: 3 od 3,0.10⁻⁵ Sv do 1,2.10³ Sv CMC 3,1 % pozycja OG-8: 4 od 5,5.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,4 % pozycja OG-8: 5 od 7,8.10⁻³ Sv do 1,2.10³ Sv CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Prostorový dávkový ekvivalent Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,2.10⁻⁶ Sv až 1,2.10³ Sv CMC 3,6 % Pozice OG-8: 3 3,0.10⁻⁵ Sv až 1,2.10³ Sv CMC 3,1 % Pozice OG-8: 4 5,5.10⁻⁴ Sv až 1,2.10³ Sv CMC 2,4 % Pozice OG-8: 5 7,8.10⁻³ Sv až 1,2.10³ Sv CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – przestrzenny rownowaznik dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,2.10⁻⁶ Sv do 1,2.10³ Sv CMC 3,6 % pozycja OG-8: 3 od 3,0.10⁻⁵ Sv do 1,2.10³ Sv CMC 3,1 % pozycja OG-8: 4 od 5,5.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,4 % pozycja OG-8: 5 od 7,8.10⁻³ Sv do 1,2.10³ Sv CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prostorovy davkovy ekvivalent Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,2.10⁻⁶ Sv az 1,2.10³ Sv CMC 3,6 % Pozice OG-8: 3 3,0.10⁻⁵ Sv az 1,2.10³ Sv CMC 3,1 % Pozice OG-8: 4 5,5.10⁻⁴ Sv az 1,2.10³ Sv CMC 2,4 % Pozice OG-8: 5 7,8.10⁻³ Sv az 1,2.10³ Sv CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,2.10⁻⁶ Sv to 1,2.10³ Sv CMC 3,6 % OG-8 position: 3 3,0.10⁻⁵ Sv to 1,2.10³ Sv CMC 3,1 % OG-8 position: 4 5,5.10⁻⁴ Sv to 1,2.10³ Sv CMC 2,4 % OG-8 position: 5 7,8.10⁻³ Sv to 1,2.10³ Sv CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,2.10⁻⁶ Sv 至 1,2.10³ Sv CMC 3,6 % OG-8 位置：3 3,0.10⁻⁵ Sv 至 1,2.10³ Sv CMC 3,1 % OG-8 位置：4 5,5.10⁻⁴ Sv 至 1,2.10³ Sv CMC 2,4 % OG-8 位置：5 7,8.10⁻³ Sv 至 1,2.10³ Sv CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"76bcba5a54b630c66dc022ea","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – przestrzenny równoważnik dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent","test_object_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Prostorový dávkový ekvivalent","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,0.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 3,6.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 1,8.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 3,4.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,0.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"3,6.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"1,8.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"3,4.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,0.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"3,6.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"1,8.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"3,4.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,0.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"3,6.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"1,8.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"3,4.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 %\npozycja OG-8: 3 od 3,6.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 %\npozycja OG-8: 4 od 1,8.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 %\npozycja OG-8: 5 od 3,4.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – przestrzenny równoważnik dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 % pozycja OG-8: 3 od 3,6.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 % pozycja OG-8: 4 od 1,8.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 % pozycja OG-8: 5 od 3,4.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Prostorový dávkový ekvivalent Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,0.10⁻⁶ Sv až 1,2.10³ Sv CMC 2,7 % Pozice OG-8: 3 3,6.10⁻⁶ Sv až 1,2.10³ Sv CMC 2,5 % Pozice OG-8: 4 1,8.10⁻⁴ Sv až 1,2.10³ Sv CMC 2,1 % Pozice OG-8: 5 3,4.10⁻⁴ Sv až 1,2.10³ Sv CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – przestrzenny rownowaznik dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 % pozycja OG-8: 3 od 3,6.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 % pozycja OG-8: 4 od 1,8.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 % pozycja OG-8: 5 od 3,4.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Prostorovy davkovy ekvivalent Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,0.10⁻⁶ Sv az 1,2.10³ Sv CMC 2,7 % Pozice OG-8: 3 3,6.10⁻⁶ Sv az 1,2.10³ Sv CMC 2,5 % Pozice OG-8: 4 1,8.10⁻⁴ Sv az 1,2.10³ Sv CMC 2,1 % Pozice OG-8: 5 3,4.10⁻⁴ Sv az 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – ambient dose equivalent Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,0.10⁻⁶ Sv to 1,2.10³ Sv CMC 2,7 % OG-8 position: 3 3,6.10⁻⁶ Sv to 1,2.10³ Sv CMC 2,5 % OG-8 position: 4 1,8.10⁻⁴ Sv to 1,2.10³ Sv CMC 2,1 % OG-8 position: 5 3,4.10⁻⁴ Sv to 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 周围剂量当量 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,0.10⁻⁶ Sv 至 1,2.10³ Sv CMC 2,7 % OG-8 位置：3 3,6.10⁻⁶ Sv 至 1,2.10³ Sv CMC 2,5 % OG-8 位置：4 1,8.10⁻⁴ Sv 至 1,2.10³ Sv CMC 2,1 % OG-8 位置：5 3,4.10⁻⁴ Sv 至 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9cd477019964b998534fa510","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – indywidualny równoważnik dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent","test_object_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Osobní dávkový ekvivalent","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,2.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"3,6 %"},{"name":"pozycja OG-8: 3","range":"od 3,0.10⁻⁵ Sv do 1,2.10³ Sv","cmc":"3,1 %"},{"name":"pozycja OG-8: 4","range":"od 5,5.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"2,4 %"},{"name":"pozycja OG-8: 5","range":"od 7,8.10⁻³ Sv do 1,2.10³ Sv","cmc":"2,0 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,2.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"3,6 %"},{"name":"OG-8 position: 3","range":"3,0.10⁻⁵ Sv to 1,2.10³ Sv","cmc":"3,1 %"},{"name":"OG-8 position: 4","range":"5,5.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"2,4 %"},{"name":"OG-8 position: 5","range":"7,8.10⁻³ Sv to 1,2.10³ Sv","cmc":"2,0 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,2.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"3,6 %"},{"name":"OG-8 位置：3","range":"3,0.10⁻⁵ Sv 至 1,2.10³ Sv","cmc":"3,1 %"},{"name":"OG-8 位置：4","range":"5,5.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"2,4 %"},{"name":"OG-8 位置：5","range":"7,8.10⁻³ Sv 至 1,2.10³ Sv","cmc":"2,0 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,2.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"3,6 %"},{"name":"Pozice OG-8: 3","range":"3,0.10⁻⁵ Sv až 1,2.10³ Sv","cmc":"3,1 %"},{"name":"Pozice OG-8: 4","range":"5,5.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"2,4 %"},{"name":"Pozice OG-8: 5","range":"7,8.10⁻³ Sv až 1,2.10³ Sv","cmc":"2,0 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,2.10⁻⁶ Sv do 1,2.10³ Sv CMC 3,6 %\npozycja OG-8: 3 od 3,0.10⁻⁵ Sv do 1,2.10³ Sv CMC 3,1 %\npozycja OG-8: 4 od 5,5.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,4 %\npozycja OG-8: 5 od 7,8.10⁻³ Sv do 1,2.10³ Sv CMC 2,0 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – indywidualny równoważnik dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,2.10⁻⁶ Sv do 1,2.10³ Sv CMC 3,6 % pozycja OG-8: 3 od 3,0.10⁻⁵ Sv do 1,2.10³ Sv CMC 3,1 % pozycja OG-8: 4 od 5,5.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,4 % pozycja OG-8: 5 od 7,8.10⁻³ Sv do 1,2.10³ Sv CMC 2,0 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Osobní dávkový ekvivalent Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,2.10⁻⁶ Sv až 1,2.10³ Sv CMC 3,6 % Pozice OG-8: 3 3,0.10⁻⁵ Sv až 1,2.10³ Sv CMC 3,1 % Pozice OG-8: 4 5,5.10⁻⁴ Sv až 1,2.10³ Sv CMC 2,4 % Pozice OG-8: 5 7,8.10⁻³ Sv až 1,2.10³ Sv CMC 2,0 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – indywidualny rownowaznik dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,2.10⁻⁶ Sv do 1,2.10³ Sv CMC 3,6 % pozycja OG-8: 3 od 3,0.10⁻⁵ Sv do 1,2.10³ Sv CMC 3,1 % pozycja OG-8: 4 od 5,5.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,4 % pozycja OG-8: 5 od 7,8.10⁻³ Sv do 1,2.10³ Sv CMC 2,0 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Osobni davkovy ekvivalent Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,2.10⁻⁶ Sv az 1,2.10³ Sv CMC 3,6 % Pozice OG-8: 3 3,0.10⁻⁵ Sv az 1,2.10³ Sv CMC 3,1 % Pozice OG-8: 4 5,5.10⁻⁴ Sv az 1,2.10³ Sv CMC 2,4 % Pozice OG-8: 5 7,8.10⁻³ Sv az 1,2.10³ Sv CMC 2,0 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,2.10⁻⁶ Sv to 1,2.10³ Sv CMC 3,6 % OG-8 position: 3 3,0.10⁻⁵ Sv to 1,2.10³ Sv CMC 3,1 % OG-8 position: 4 5,5.10⁻⁴ Sv to 1,2.10³ Sv CMC 2,4 % OG-8 position: 5 7,8.10⁻³ Sv to 1,2.10³ Sv CMC 2,0 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,2.10⁻⁶ Sv 至 1,2.10³ Sv CMC 3,6 % OG-8 位置：3 3,0.10⁻⁵ Sv 至 1,2.10³ Sv CMC 3,1 % OG-8 位置：4 5,5.10⁻⁴ Sv 至 1,2.10³ Sv CMC 2,4 % OG-8 位置：5 7,8.10⁻³ Sv 至 1,2.10³ Sv CMC 2,0 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bee8793e23efca0f2fc8693d","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – indywidualny równoważnik dawki","test_object_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent","test_object_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量","test_object_cs":"Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Osobní dávkový ekvivalent","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"pozycja OG-8: 2","range":"od 1,0.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"2,7 %"},{"name":"pozycja OG-8: 3","range":"od 3,5.10⁻⁶ Sv do 1,2.10³ Sv","cmc":"2,5 %"},{"name":"pozycja OG-8: 4","range":"od 1,7.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"2,1 %"},{"name":"pozycja OG-8: 5","range":"od 3,1.10⁻⁴ Sv do 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_en":[{"name":"OG-8 position: 2","range":"1,0.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"2,7 %"},{"name":"OG-8 position: 3","range":"3,5.10⁻⁶ Sv to 1,2.10³ Sv","cmc":"2,5 %"},{"name":"OG-8 position: 4","range":"1,7.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"2,1 %"},{"name":"OG-8 position: 5","range":"3,1.10⁻⁴ Sv to 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_zh":[{"name":"OG-8 位置：2","range":"1,0.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"2,7 %"},{"name":"OG-8 位置：3","range":"3,5.10⁻⁶ Sv 至 1,2.10³ Sv","cmc":"2,5 %"},{"name":"OG-8 位置：4","range":"1,7.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"2,1 %"},{"name":"OG-8 位置：5","range":"3,1.10⁻⁴ Sv 至 1,2.10³ Sv","cmc":"1,7 %"}],"parameters_cs":[{"name":"Pozice OG-8: 2","range":"1,0.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"2,7 %"},{"name":"Pozice OG-8: 3","range":"3,5.10⁻⁶ Sv až 1,2.10³ Sv","cmc":"2,5 %"},{"name":"Pozice OG-8: 4","range":"1,7.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"2,1 %"},{"name":"Pozice OG-8: 5","range":"3,1.10⁻⁴ Sv až 1,2.10³ Sv","cmc":"1,7 %"}],"technique":"Pomiar na napromienniaczu OG8","technique_en":"Measurement on the OG8 irradiator","technique_zh":"在 OG8 辐照器上测量","technique_cs":"Měření na ozařovači OG8","techniques":["Pomiar na napromienniaczu OG8"],"techniques_en":["Measurement on the OG8 irradiator"],"techniques_zh":["在 OG8 辐照器上测量"],"techniques_cs":["Měření na ozařovači OG8"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\npozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 %\npozycja OG-8: 3 od 3,5.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 %\npozycja OG-8: 4 od 1,7.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 %\npozycja OG-8: 5 od 3,1.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 %\nPomiar na napromienniaczu OG8","reference":"J61.02.R01.2","norm_bases":["J61.02.R01.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy do pomiaru przestrzennych i indywidualnych wielkości dozymetrycznych – indywidualny równoważnik dawki Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 % pozycja OG-8: 3 od 3,5.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 % pozycja OG-8: 4 od 1,7.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 % pozycja OG-8: 5 od 3,1.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 % Měřidla prostorových dozimetrických a osobních dozimetrických veličin – Osobní dávkový ekvivalent Kalibrace – veličiny atomové a jaderné fyziky Měření na ozařovači OG8 Pozice OG-8: 2 1,0.10⁻⁶ Sv až 1,2.10³ Sv CMC 2,7 % Pozice OG-8: 3 3,5.10⁻⁶ Sv až 1,2.10³ Sv CMC 2,5 % Pozice OG-8: 4 1,7.10⁻⁴ Sv až 1,2.10³ Sv CMC 2,1 % Pozice OG-8: 5 3,1.10⁻⁴ Sv až 1,2.10³ Sv CMC 1,7 % J61.02.R01.2 Przyrzady do pomiaru przestrzennych i indywidualnych wielkosci dozymetrycznych – indywidualny rownowaznik dawki Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar na napromienniaczu OG8 pozycja OG-8: 2 od 1,0.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,7 % pozycja OG-8: 3 od 3,5.10⁻⁶ Sv do 1,2.10³ Sv CMC 2,5 % pozycja OG-8: 4 od 1,7.10⁻⁴ Sv do 1,2.10³ Sv CMC 2,1 % pozycja OG-8: 5 od 3,1.10⁻⁴ Sv do 1,2.10³ Sv CMC 1,7 % Meridla prostorovych dozimetrickych a osobnich dozimetrickych velicin – Osobni davkovy ekvivalent Kalibrace – veliciny atomove a jaderne fyziky Mereni na ozarovaci OG8 Pozice OG-8: 2 1,0.10⁻⁶ Sv az 1,2.10³ Sv CMC 2,7 % Pozice OG-8: 3 3,5.10⁻⁶ Sv az 1,2.10³ Sv CMC 2,5 % Pozice OG-8: 4 1,7.10⁻⁴ Sv az 1,2.10³ Sv CMC 2,1 % Pozice OG-8: 5 3,1.10⁻⁴ Sv az 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","search_en":"Meters of ambient and personal dosimetric quantities – personal dose equivalent Calibration – atomic and nuclear physics quantities Measurement on the OG8 irradiator OG-8 position: 2 1,0.10⁻⁶ Sv to 1,2.10³ Sv CMC 2,7 % OG-8 position: 3 3,5.10⁻⁶ Sv to 1,2.10³ Sv CMC 2,5 % OG-8 position: 4 1,7.10⁻⁴ Sv to 1,2.10³ Sv CMC 2,1 % OG-8 position: 5 3,1.10⁻⁴ Sv to 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","search_zh":"周围和个人剂量学量测量仪器 – 个人剂量当量 校准 – 原子和核物理量 在 OG8 辐照器上测量 OG-8 位置：2 1,0.10⁻⁶ Sv 至 1,2.10³ Sv CMC 2,7 % OG-8 位置：3 3,5.10⁻⁶ Sv 至 1,2.10³ Sv CMC 2,5 % OG-8 位置：4 1,7.10⁻⁴ Sv 至 1,2.10³ Sv CMC 2,1 % OG-8 位置：5 3,1.10⁻⁴ Sv 至 1,2.10³ Sv CMC 1,7 % J61.02.R01.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"668a3929a6dc73c21c9337e7","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"2","test_object":"Mierniki skażenia powierzchni radionuklidami alfa i beta","test_object_en":"Meters of surface contamination by alpha and beta radionuclides","test_object_zh":"α和β放射性核素表面污染测量仪","test_object_cs":"Měřidla kontaminace povrchu radionuklidy alfa a beta","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"Aktywność powierzchniowa radionuklidów alfa","range":"od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"Aktywność powierzchniowa radionuklidów beta","range":"od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"Aktywność radionuklidów alfa","range":"od 2,0.10¹ Bq do 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"Aktywność radionuklidów beta","range":"od 4,0.10¹ Bq do 1,0.10⁶ Bq","cmc":"2,0 %"}],"parameters_en":[{"name":"Surface activity of alpha radionuclides","range":"1,0.10⁻¹ Bq/cm² to 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"Surface activity of beta radionuclides","range":"1,0.10⁻¹ Bq/cm² to 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"Activity of alpha radionuclides","range":"2,0.10¹ Bq to 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"Activity of beta radionuclides","range":"4,0.10¹ Bq to 1,0.10⁶ Bq","cmc":"2,0 %"}],"parameters_zh":[{"name":"α放射性核素表面活度","range":"1,0.10⁻¹ Bq/cm² 至 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"β放射性核素表面活度","range":"1,0.10⁻¹ Bq/cm² 至 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"α放射性核素活度","range":"2,0.10¹ Bq 至 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"β放射性核素活度","range":"4,0.10¹ Bq 至 1,0.10⁶ Bq","cmc":"2,0 %"}],"parameters_cs":[{"name":"Plošná aktivita radionuklidů alfa","range":"1,0.10⁻¹ Bq/cm² až 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"Plošná aktivita radionuklidů beta","range":"1,0.10⁻¹ Bq/cm² až 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"Aktivita radionuklidů alfa","range":"2,0.10¹ Bq až 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"Aktivita radionuklidů beta","range":"4,0.10¹ Bq až 1,0.10⁶ Bq","cmc":"2,0 %"}],"technique":"Pomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ)","technique_en":"Measurement using area sources of ionising radiation (IZ)","technique_zh":"使用电离辐射 (IZ) 面源测量","technique_cs":"Měření pomocí plošných zdrojů IZ","techniques":["Pomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ)"],"techniques_en":["Measurement using area sources of ionising radiation (IZ)"],"techniques_zh":["使用电离辐射 (IZ) 面源测量"],"techniques_cs":["Měření pomocí plošných zdrojů IZ"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\nAktywność powierzchniowa radionuklidów alfa od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm² CMC 1,6 %\nAktywność powierzchniowa radionuklidów beta od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm² CMC 1,6 %\nAktywność radionuklidów alfa od 2,0.10¹ Bq do 2,0.10⁵ Bq CMC 1,0 %\nAktywność radionuklidów beta od 4,0.10¹ Bq do 1,0.10⁶ Bq CMC 2,0 %\nPomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ)","reference":"J61.02.R03.2","norm_bases":["J61.02.R03.2"],"lab_section":"Metrologia promieniowania jonizującego EDU","lab_section_en":"Ionising Radiation Metrology EDU","lab_section_zh":"电离辐射计量 EDU","lab_section_cs":"Metrologie ionizujícího záření EDU","lab_address":"Jaderná elektrárna Dukovany, 675 50","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki skażenia powierzchni radionuklidami alfa i beta Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ) Aktywność powierzchniowa radionuklidów alfa od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm² CMC 1,6 % Aktywność powierzchniowa radionuklidów beta od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm² CMC 1,6 % Aktywność radionuklidów alfa od 2,0.10¹ Bq do 2,0.10⁵ Bq CMC 1,0 % Aktywność radionuklidów beta od 4,0.10¹ Bq do 1,0.10⁶ Bq CMC 2,0 % Měřidla kontaminace povrchu radionuklidy alfa a beta Kalibrace – veličiny atomové a jaderné fyziky Měření pomocí plošných zdrojů IZ Plošná aktivita radionuklidů alfa 1,0.10⁻¹ Bq/cm² až 4,0.10² Bq/cm² CMC 1,6 % Plošná aktivita radionuklidů beta 1,0.10⁻¹ Bq/cm² až 35.10³ Bq/cm² CMC 1,6 % Aktivita radionuklidů alfa 2,0.10¹ Bq až 2,0.10⁵ Bq CMC 1,0 % Aktivita radionuklidů beta 4,0.10¹ Bq až 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2 Mierniki skazenia powierzchni radionuklidami alfa i beta Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar za pomoca powierzchniowych zrodel promieniowania jonizujacego (IZ) Aktywnosc powierzchniowa radionuklidow alfa od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm² CMC 1,6 % Aktywnosc powierzchniowa radionuklidow beta od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm² CMC 1,6 % Aktywnosc radionuklidow alfa od 2,0.10¹ Bq do 2,0.10⁵ Bq CMC 1,0 % Aktywnosc radionuklidow beta od 4,0.10¹ Bq do 1,0.10⁶ Bq CMC 2,0 % Meridla kontaminace povrchu radionuklidy alfa a beta Kalibrace – veliciny atomove a jaderne fyziky Mereni pomoci plosnych zdroju IZ Plosna aktivita radionuklidu alfa 1,0.10⁻¹ Bq/cm² az 4,0.10² Bq/cm² CMC 1,6 % Plosna aktivita radionuklidu beta 1,0.10⁻¹ Bq/cm² az 35.10³ Bq/cm² CMC 1,6 % Aktivita radionuklidu alfa 2,0.10¹ Bq az 2,0.10⁵ Bq CMC 1,0 % Aktivita radionuklidu beta 4,0.10¹ Bq az 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2","search_en":"Meters of surface contamination by alpha and beta radionuclides Calibration – atomic and nuclear physics quantities Measurement using area sources of ionising radiation (IZ) Surface activity of alpha radionuclides 1,0.10⁻¹ Bq/cm² to 4,0.10² Bq/cm² CMC 1,6 % Surface activity of beta radionuclides 1,0.10⁻¹ Bq/cm² to 35.10³ Bq/cm² CMC 1,6 % Activity of alpha radionuclides 2,0.10¹ Bq to 2,0.10⁵ Bq CMC 1,0 % Activity of beta radionuclides 4,0.10¹ Bq to 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2","search_zh":"α和β放射性核素表面污染测量仪 校准 – 原子和核物理量 使用电离辐射 (IZ) 面源测量 α放射性核素表面活度 1,0.10⁻¹ Bq/cm² 至 4,0.10² Bq/cm² CMC 1,6 % β放射性核素表面活度 1,0.10⁻¹ Bq/cm² 至 35.10³ Bq/cm² CMC 1,6 % α放射性核素活度 2,0.10¹ Bq 至 2,0.10⁵ Bq CMC 1,0 % β放射性核素活度 4,0.10¹ Bq 至 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f743437baa24d01263d944f","lab_id":"6ade8b2aff068247617080fd","country":"CZ","accr_number":"2245.2","accr_body":"ČIA","row_label":"2","test_object":"Mierniki skażenia powierzchni radionuklidami alfa i beta","test_object_en":"Meters of surface contamination by alpha and beta radionuclides","test_object_zh":"α和β放射性核素表面污染测量仪","test_object_cs":"Měřidla kontaminace povrchu radionuklidy alfa a beta","methodology":"Wzorcowanie – wielkości fizyki atomowej i jądrowej","methodology_en":"Calibration – atomic and nuclear physics quantities","methodology_zh":"校准 – 原子和核物理量","methodology_cs":"Kalibrace – veličiny atomové a jaderné fyziky","parameters":[{"name":"Aktywność powierzchniowa radionuklidów alfa","range":"od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"Aktywność powierzchniowa radionuklidów beta","range":"od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"Aktywność radionuklidów alfa","range":"od 2,0.10¹ Bq do 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"Aktywność radionuklidów beta","range":"od 4,0.10¹ Bq do 1,0.10⁶ Bq","cmc":"2,0 %"}],"parameters_en":[{"name":"Surface activity of alpha radionuclides","range":"1,0.10⁻¹ Bq/cm² to 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"Surface activity of beta radionuclides","range":"1,0.10⁻¹ Bq/cm² to 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"Activity of alpha radionuclides","range":"2,0.10¹ Bq to 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"Activity of beta radionuclides","range":"4,0.10¹ Bq to 1,0.10⁶ Bq","cmc":"2,0 %"}],"parameters_zh":[{"name":"α放射性核素表面活度","range":"1,0.10⁻¹ Bq/cm² 至 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"β放射性核素表面活度","range":"1,0.10⁻¹ Bq/cm² 至 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"α放射性核素活度","range":"2,0.10¹ Bq 至 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"β放射性核素活度","range":"4,0.10¹ Bq 至 1,0.10⁶ Bq","cmc":"2,0 %"}],"parameters_cs":[{"name":"Plošná aktivita radionuklidů alfa","range":"1,0.10⁻¹ Bq/cm² až 4,0.10² Bq/cm²","cmc":"1,6 %"},{"name":"Plošná aktivita radionuklidů beta","range":"1,0.10⁻¹ Bq/cm² až 35.10³ Bq/cm²","cmc":"1,6 %"},{"name":"Aktivita radionuklidů alfa","range":"2,0.10¹ Bq až 2,0.10⁵ Bq","cmc":"1,0 %"},{"name":"Aktivita radionuklidů beta","range":"4,0.10¹ Bq až 1,0.10⁶ Bq","cmc":"2,0 %"}],"technique":"Pomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ)","technique_en":"Measurement using area sources of ionising radiation (IZ)","technique_zh":"使用电离辐射 (IZ) 面源测量","technique_cs":"Měření pomocí plošných zdrojů IZ","techniques":["Pomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ)"],"techniques_en":["Measurement using area sources of ionising radiation (IZ)"],"techniques_zh":["使用电离辐射 (IZ) 面源测量"],"techniques_cs":["Měření pomocí plošných zdrojů IZ"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości fizyki atomowej i jądrowej\nZakres:\nAktywność powierzchniowa radionuklidów alfa od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm² CMC 1,6 %\nAktywność powierzchniowa radionuklidów beta od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm² CMC 1,6 %\nAktywność radionuklidów alfa od 2,0.10¹ Bq do 2,0.10⁵ Bq CMC 1,0 %\nAktywność radionuklidów beta od 4,0.10¹ Bq do 1,0.10⁶ Bq CMC 2,0 %\nPomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ)","reference":"J61.02.R03.2","norm_bases":["J61.02.R03.2"],"lab_section":"Metrologia promieniowania jonizującego ETE","lab_section_en":"Ionising Radiation Metrology ETE","lab_section_zh":"电离辐射计量 ETE","lab_section_cs":"Metrologie ionizujícího záření ETE","lab_address":"Jaderná elektrárna Temelín, 373 05","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości fizyki atomowej i jądrowej","regulatory_area_en":"CMC for the field of measured quantity: Atomic and nuclear physics quantities","regulatory_area_zh":"被测量领域的CMC：原子和核物理量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny atomové a jaderné fyziky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mierniki skażenia powierzchni radionuklidami alfa i beta Wzorcowanie – wielkości fizyki atomowej i jądrowej Pomiar za pomocą powierzchniowych źródeł promieniowania jonizującego (IZ) Aktywność powierzchniowa radionuklidów alfa od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm² CMC 1,6 % Aktywność powierzchniowa radionuklidów beta od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm² CMC 1,6 % Aktywność radionuklidów alfa od 2,0.10¹ Bq do 2,0.10⁵ Bq CMC 1,0 % Aktywność radionuklidów beta od 4,0.10¹ Bq do 1,0.10⁶ Bq CMC 2,0 % Měřidla kontaminace povrchu radionuklidy alfa a beta Kalibrace – veličiny atomové a jaderné fyziky Měření pomocí plošných zdrojů IZ Plošná aktivita radionuklidů alfa 1,0.10⁻¹ Bq/cm² až 4,0.10² Bq/cm² CMC 1,6 % Plošná aktivita radionuklidů beta 1,0.10⁻¹ Bq/cm² až 35.10³ Bq/cm² CMC 1,6 % Aktivita radionuklidů alfa 2,0.10¹ Bq až 2,0.10⁵ Bq CMC 1,0 % Aktivita radionuklidů beta 4,0.10¹ Bq až 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2 Mierniki skazenia powierzchni radionuklidami alfa i beta Wzorcowanie – wielkosci fizyki atomowej i jadrowej Pomiar za pomoca powierzchniowych zrodel promieniowania jonizujacego (IZ) Aktywnosc powierzchniowa radionuklidow alfa od 1,0.10⁻¹ Bq/cm² do 4,0.10² Bq/cm² CMC 1,6 % Aktywnosc powierzchniowa radionuklidow beta od 1,0.10⁻¹ Bq/cm² do 35.10³ Bq/cm² CMC 1,6 % Aktywnosc radionuklidow alfa od 2,0.10¹ Bq do 2,0.10⁵ Bq CMC 1,0 % Aktywnosc radionuklidow beta od 4,0.10¹ Bq do 1,0.10⁶ Bq CMC 2,0 % Meridla kontaminace povrchu radionuklidy alfa a beta Kalibrace – veliciny atomove a jaderne fyziky Mereni pomoci plosnych zdroju IZ Plosna aktivita radionuklidu alfa 1,0.10⁻¹ Bq/cm² az 4,0.10² Bq/cm² CMC 1,6 % Plosna aktivita radionuklidu beta 1,0.10⁻¹ Bq/cm² az 35.10³ Bq/cm² CMC 1,6 % Aktivita radionuklidu alfa 2,0.10¹ Bq az 2,0.10⁵ Bq CMC 1,0 % Aktivita radionuklidu beta 4,0.10¹ Bq az 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2","search_en":"Meters of surface contamination by alpha and beta radionuclides Calibration – atomic and nuclear physics quantities Measurement using area sources of ionising radiation (IZ) Surface activity of alpha radionuclides 1,0.10⁻¹ Bq/cm² to 4,0.10² Bq/cm² CMC 1,6 % Surface activity of beta radionuclides 1,0.10⁻¹ Bq/cm² to 35.10³ Bq/cm² CMC 1,6 % Activity of alpha radionuclides 2,0.10¹ Bq to 2,0.10⁵ Bq CMC 1,0 % Activity of beta radionuclides 4,0.10¹ Bq to 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2","search_zh":"α和β放射性核素表面污染测量仪 校准 – 原子和核物理量 使用电离辐射 (IZ) 面源测量 α放射性核素表面活度 1,0.10⁻¹ Bq/cm² 至 4,0.10² Bq/cm² CMC 1,6 % β放射性核素表面活度 1,0.10⁻¹ Bq/cm² 至 35.10³ Bq/cm² CMC 1,6 % α放射性核素活度 2,0.10¹ Bq 至 2,0.10⁵ Bq CMC 1,0 % β放射性核素活度 4,0.10¹ Bq 至 1,0.10⁶ Bq CMC 2,0 % J61.02.R03.2","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}