🇨🇿 ČEZ, a. s. PL
Metrology & calibration
ČEZ, a. s. is a calibration laboratory accredited by ČIA under number 2245 (Temelín, Czech Republic). Its accreditation scope covers 93 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC current / AC current meters and generators, DC current / DC current meters and generators, AC voltage / AC voltage meters and generators, DC resistance / DC resistance meters and generators. Most frequently used calibration principles: Direct generation with a calibrator, Comparison with a reference resistance thermometer in a liquid bath, Direct measurement using a multimeter.
At a glance
- Accreditation number: ČIA 2245
- Calibration items in scope: 93
- Types of calibrated items: 34
- Calibration principles used: 27
- City: Temelín, Czech Republic
- Valid until: 18-01-2029
- Accreditation number
- 2245
- Accreditation body
- ČIA
- Address
- JE Temelín, 373 05 Temelín
- City
- Temelín, Czech Republic
- Division
- Laboratorium wzorcujące – metrologia
- Valid until
- 18-01-2029
What this laboratory calibrates (34)
- AC current / AC current meters and generators — 8 calibration items
- DC current / DC current meters and generators — 8 calibration items
- AC voltage / AC voltage meters and generators — 4 calibration items
- DC resistance / DC resistance meters and generators — 4 calibration items
- DC voltage / DC voltage meters and generators — 4 calibration items
- Deformation and digital manometers, pressure transducers including differential, pressure measuring chains — 4 calibration items
- Direct-indicating thermometers — 4 calibration items
- Measurement and simulation of temperature sensors / temperature gauges — 4 calibration items
- Resistance temperature sensors — 4 calibration items
- Weld gauges / angular scales — 4 calibration items
- Weld gauges / linear scales — 4 calibration items
- Conductivity / conductivity meters (only the electrical part of the instrument) — 2 calibration items
- Electrical power / power meters (50 Hz, up to 740 V) — 2 calibration items
- Glass thermometers — 2 calibration items
- Indicators / dial, digital, lever — 2 calibration items
- and 19 more
Calibration principles (27)
- Direct generation with a calibrator — 15 calibration items
- Comparison with a reference resistance thermometer in a liquid bath — 11 calibration items
- Direct measurement using a multimeter — 10 calibration items
- Measurement using parallel gauge blocks — 6 calibration items
- Calibrator generation with current simulation using a current coil — 5 calibration items
- Direct measurement at triple point of water — 5 calibration items
- Measurement by setting rings — 4 calibration items
- Calibration with a reference torque device — 2 calibration items
- Comparison with a reference digital manometer — 2 calibration items
- Comparison with a reference electronic thermometer in a vertical furnace — 2 calibration items
- Comparison with a reference standard — 2 calibration items
- Comparison with a standard piston pressure gauge — 2 calibration items
- Direct generation by calibrator / reference resistors / resistance boxes — 2 calibration items
- Direct resistance generation by a calibrator / resistance box — 2 calibration items
- Direct voltage generation by a calibrator — 2 calibration items
- and 12 more
Laboratory sections (2)
- Nuclear Power Plant Dukovany — 49 calibration items
- Nuclear Power Plant Temelín — 44 calibration items
Laboratory locations
- ČEZ, a. s. (main site) — JE Temelín, 373 05 Temelín
- Elektrownia jądrowa Dukovany — Modřínová 1094, 674 01 Třebíč
- Elektrownia jądrowa Temelín — 373 05 Temelín
Certificate information
- Certificate date
- 11.09.2026
Accreditation scope — calibration items (93)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Nuclear Power Plant Dukovany | |||||
| 1 | Micrometer gauges, micrometers for external measurement | Calibration – length 0 mm to 100 mm · CMC 0,0012 mm 100 mm to 500 mm · CMC 0,0013 mm 500 mm to 700 mm · CMC 0,0014 mm 700 mm to 900 mm · CMC 0,0015 mm 900 mm to 1 000 mm · CMC 0,0016 mm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | J 62.03.G01 | |
| 2 | Micrometers for internal measurement | Calibration – length 5 mm to 45 mm · CMC 0,0019 mm CMC for the field of measured quantity: Length |
Measurement by setting rings | J 62.03.G01 | |
| 3 | Three-contact internal gauges | Calibration – length 6 mm to 200 mm · CMC 0,0019 mm CMC for the field of measured quantity: Length |
Measurement by setting rings | J 62.03.G01 | |
| 4 | Slide gauges | Calibration – length 0 mm to 2 000 mm · CMC 0,012 mm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | J 62.03.G02 | |
| 5 | Indicators / dial, digital, lever | Calibration – length division 0.001 mm — 0 mm to 5 mm · CMC 0,00033 mm division 0.001 mm — 5 mm to 13 mm · CMC 0,00034 mm division 0.01 mm — 0 mm to 50 mm · CMC 0,0012 mm division 0.01 mm — 50 mm to 100 mm · CMC 0,0013 mm CMC for the field of measured quantity: Length |
Measurement on a dial indicator calibration instrument | J 62.03.G03 | |
| 6 | Weld gauges / linear scales | Calibration – length 0 mm to 50 mm · CMC 0,026 mm CMC for the field of measured quantity: Length |
Measuring with a slide gauge | J 62.03.G04 | |
| 7 | Weld gauges / linear scales | Calibration – length 50 mm to 60 mm · CMC 0,23 mm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | J 62.03.G04 | |
| 8 | Weld gauges / angular scales | Calibration – plane angle 0° to 90° · CMC 0,1° CMC for the field of measured quantity: Plane angle |
Measuring with an angle gauge | J 62.03.G04 | |
| 9 | Weld gauges / angular scales | Calibration – plane angle 90° to 150° · CMC 1,2° CMC for the field of measured quantity: Plane angle |
Measurement using angle gauges | J 62.03.G04 | |
| 10 | Scales with non-automatic function, electronic | Calibration – mass According to the weights used for calibration, Uᵢ can have the following values — 1 mg to 19 kg · CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg CMC for the field of measured quantity: Mass |
Load with standard weights (according to OIML R 111-1:2004) class E2 | J 62.06.W01 | |
| 11 | F1, F2, M class weights | Calibration – mass 1 mg to 5 mg · CMC 4,6·10⁻³ mg 10 mg · CMC 4,9·10⁻³ mg 20 mg · CMC 5,3·10⁻³ mg 50 mg · CMC 5,8·10⁻³ mg 100 mg · CMC 6,8·10⁻³ mg 200 mg · CMC 8,0·10⁻³ mg 500 mg · CMC 1,0·10⁻² mg 1 g · CMC 1,1·10⁻² mg 2 g · CMC 1,4·10⁻² mg 5 g · CMC 1,8·10⁻² mg 10 g · CMC 2,1·10⁻² mg 20 g · CMC 2,7·10⁻² mg 50 g · CMC 3,4·10⁻² mg 100 g · CMC 5,5·10⁻² mg 200 g · CMC 1,1·10⁻¹ mg 500 g · CMC 8,2·10⁰ mg 1 kg · CMC 8,2·10⁰ mg 2 kg · CMC 8,3·10⁰ mg 5 kg · CMC 8,6·10⁰ mg 10 kg · CMC 8,2·10¹ mg CMC for the field of measured quantity: Mass |
Comparison with a standard weight (according to OIML R 111-1:2004) of class E2 on reference scales | J 62.03.W02 | |
| 12 | Torque / torque wrenches, torque screwdrivers | Calibration – torque 1 N·m to 1000 N·m · CMC 0,7 % CMC for the field of measured quantity: Torque |
Calibration with a reference torque device | J 62.03.S01 | |
| 13 | Deformation and digital manometers, pressure transducers including differential, pressure measuring chains | Calibration – pressure gas, absolute pressure — 0 kPa to 63 kPa · CMC 7,4 Pa gas, absolute pressure — 63 kPa to 7 MPa · CMC 0,007 % gas, gauge pressure — −100 kPa to −72 kPa · CMC 0,01 % gas, gauge pressure — −72 kPa to 0 kPa · CMC 8,5 Pa gas, gauge pressure — 16 kPa to 72 kPa · CMC 8,5 Pa gas, gauge pressure — 72 kPa to 7 MPa · CMC 0,007 % gas, barometric pressure — 70 kPa to 110 kPa · CMC 0,011 % CMC for the field of measured quantity: Pressure |
Comparison with a reference digital manometer | J62.03.P01, J62.03.P02, J62.03.P03 | |
| 14 | Deformation and digital manometers, pressure transducers including differential, pressure measuring chains | Calibration – pressure gas, gauge pressure — 0 Pa to 500 Pa · CMC 0,2 Pa gas, gauge pressure — 0,5 kPa to 16 kPa · CMC 0,027 % gas, gauge pressure — 7 MPa to 20 MPa · CMC 0,005 % gas, pressure difference at stat. pressure (0.1 to 20.1) MPa — 0 kPa to 500 kPa · CMC 0,014 % oil, gauge pressure, absolute pressure — 0 kPa to 350 kPa · CMC 0,042 kPa oil, gauge pressure, absolute pressure — 350 kPa to 3 MPa · CMC 0,009 % oil, gauge pressure, absolute pressure — 3 MPa to 10 MPa · CMC 0,46 kPa oil, gauge pressure, absolute pressure — 10 MPa to 100 MPa · CMC 0,005 % CMC for the field of measured quantity: Pressure |
Comparison with a standard piston pressure gauge | J62.03.P01, J62.03.P02, J62.03.P03 | |
| 15 | Platinum resistance thermometers | Calibration – temperature 0,01 °C · CMC 0,004 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | J 62.03.T04 | |
| 16 | Platinum resistance thermometers | Calibration – temperature −40 °C to 0 °C · CMC 0,010 °C 0 °C to 232 °C · CMC (1,3·10⁻⁵·t + 0,008) °C 232 °C to 420 °C · CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T04 | |
| 17 | Resistance temperature sensors | Calibration – temperature 0,01 °C · CMC 0,01 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | J 62.03.T01 | |
| 18 | Resistance temperature sensors | Calibration – temperature −40 °C to 0 °C · CMC 0,02 °C 0 °C to 232 °C · CMC (5·10⁻⁵·t + 0,02) °C 232 °C to 400 °C · CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C to 550 °C · CMC (2·10⁻⁴·(t − 400) + 0,06) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T01 | |
| 19 | Glass thermometers | Calibration – temperature −40 °C to 100 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T03 | |
| 20 | Thermocouple temperature sensors | Calibration – temperature −40 °C to 0 °C · CMC 0,5 °C 0 °C to 400 °C · CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C to 550 °C · CMC (2·10⁻³·(t − 400) + 0,5) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T02 | |
| 21 | Temperature sensors with transducer | Calibration – temperature −40 °C to 0 °C · CMC 0,03 °C 0 °C to 400 °C · CMC (1·10⁻⁴·t + 0,03) °C 400 °C to 550 °C · CMC (4·10⁻⁴·(t − 400) + 0,07) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T06 | |
| 22 | Direct-indicating thermometers | Calibration – temperature 0,01 °C · CMC 0,004 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | J 62.03.T05 | |
| 23 | Direct-indicating thermometers | Calibration – temperature −40 °C to 0 °C · CMC 0,02 °C 0 °C to 400 °C · CMC (1·10⁻⁴·t + 0,02) °C 400 °C to 550 °C · CMC (2·10⁻⁴·(t − 400) + 0,06) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T05 | |
| 24 | Temperature measuring chains, including thermal sensors | Calibration – temperature −30 °C to 0 °C · CMC 0,1 °C 0 °C to 400 °C · CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C to 660 °C · CMC 1,5·10⁻³·(t − 400) + 0,2) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference electronic thermometer in a vertical furnace | J 62.03.T05 | |
| 25 | Analogue and digital hygrometers, humidity transducers and humidity measuring chains, including humidity probes | Calibration – air humidity (15 to 35) °C — 10 % RH to 70 % RH · CMC 2,0 % RH (15 to 35) °C — 70 % RH to 90 % RH · CMC 2,3 % RH CMC for the field of measured quantity: Air humidity |
Comparison with a reference humidity transducer in a climatic chamber | J 62.03.M01 | |
| 26 | DC voltage / DC voltage meters and generators | Calibration – electrical quantities 0 mV to 220 mV · CMC 11 µV/V + 0,4 µV 220 mV to 2,2 V · CMC 6,4 µV/V 2,2 V to 11 V · CMC 4,9 µV/V 11 V to 22 V · CMC 4,7 µV/V 22 V to 220 V · CMC 6,4 µV/V 220 V to 1100 V · CMC 8,5 µV/V CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 | |
| 27 | DC voltage / DC voltage meters and generators | Calibration – electrical quantities 0 mV to 100 mV · CMC 9 µV/V + 0,3 µV 100 mV to 1 V · CMC 6,2 µV/V 1 V to 10 V · CMC 5,4 µV/V 10 V to 1000 V · CMC 8,2 µV/V CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 | |
| 28 | DC current / DC current meters and generators | Calibration – electrical quantities 0 µA to 220 µA · CMC 80 µA/A + 6 nA 220 µA to 2,2 mA · CMC 46 µA/A 2,2 mA to 22 mA · CMC 44 µA/A 22 mA to 220 mA · CMC 57 µA/A 220 mA to 2,2 A · CMC 0,01 % 2,2 A to 20 A · CMC 0,048 % 20 A to 120 A · CMC 0,035 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 29 | DC current / DC current meters and generators | Calibration – electrical quantities 120 A to 1000 A · CMC 0,65 % CMC for the field of measured quantity: Electrical quantities |
Calibrator generation with current simulation using a current coil | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 30 | DC current / DC current meters and generators | Calibration – electrical quantities 0 µA to 10 µA · CMC 0,018 % + 1,2 nA 10 µA to 100 µA · CMC 63 µA/A 100 µA to 1 mA · CMC 39 µA/A 1 mA to 10 mA · CMC 38 µA/A 10 mA to 100 mA · CMC 54 µA/A 100 mA to 1 A · CMC 0,015 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 31 | DC current / DC current meters and generators | Calibration – electrical quantities 1 A to 20 A · CMC 0,024 % 20 A to 100 A · CMC 0,058 % CMC for the field of measured quantity: Electrical quantities |
Measurement with a multimeter on a current shunt | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 32 | DC resistance / DC resistance meters and generators | Calibration – electrical quantities 0 Ω · CMC 50 µΩ 0,01 Ω to 0,1 Ω · CMC 1 % 0,1 Ω to 1 Ω · CMC 0,2 % 1 Ω to 10 Ω · CMC 0,05 % 10 Ω to 100 kΩ · CMC 0,01 % 100 kΩ to 1 MΩ · CMC 0,02 % 1 MΩ to 10 MΩ · CMC 0,05 % 10 MΩ to 100 MΩ · CMC 0,1 % 100 MΩ to 100 GΩ · CMC 1 % 100 GΩ to 1000 GΩ · CMC 4 % 1 mΩ · CMC 0,01 % 10 mΩ · CMC 0,01 % 100 mΩ · CMC 0,01 % 1 Ω · CMC 0,01 % 1,9 Ω · CMC 0,011 % 10 Ω · CMC 27 µΩ/Ω 19 Ω · CMC 27 µΩ/Ω 100 Ω · CMC 12 µΩ/Ω 190 Ω · CMC 12 µΩ/Ω 1 kΩ · CMC 8 µΩ/Ω 1,9 kΩ · CMC 8 µΩ/Ω 10 kΩ · CMC 8 µΩ/Ω 19 kΩ · CMC 8 µΩ/Ω 100 kΩ · CMC 10 µΩ/Ω 190 kΩ · CMC 12 µΩ/Ω 1 MΩ · CMC 15 µΩ/Ω 1,9 MΩ · CMC 21 µΩ/Ω 10 MΩ · CMC 46 µΩ/Ω 19 MΩ · CMC 55 µΩ/Ω 100 MΩ · CMC 0,012 % 10 GΩ · CMC 0,2 % CMC for the field of measured quantity: Electrical quantities |
Direct generation by calibrator / reference resistors / resistance boxes | J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 | |
| 33 | DC resistance / DC resistance meters and generators | Calibration – electrical quantities 0,01 Ω to 10 Ω · CMC 27 µΩ/Ω 10 Ω to 100 Ω · CMC 22 µΩ/Ω 100 Ω to 10 kΩ · CMC 14 µΩ/Ω 10 kΩ to 100 kΩ · CMC 15 µΩ/Ω 100 kΩ to 1 MΩ · CMC 26 µΩ/Ω 1 MΩ to 10 MΩ · CMC 77 µΩ/Ω 10 MΩ to 100 MΩ · CMC 0,064 % 100 MΩ to 1 GΩ · CMC 0,58 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 | |
| 34 | AC voltage / AC voltage meters and generators | Calibration – electrical quantities 40 Hz to 20 kHz — 1 mV to 22 mV · CMC 0,41 % 40 Hz to 20 kHz — 22 mV to 220 mV · CMC 0,038 % 40 Hz to 20 kHz — 220 mV to 2,2 V · CMC 0,015 % 40 Hz to 20 kHz — 2,2 V to 11 V · CMC 59 µV/V 40 Hz to 20 kHz — 11 V to 22 V · CMC 57 µV/V 40 Hz to 20 kHz — 22 V to 220 V · CMC 65 µV/V 50 Hz to 1 kHz — 220 V to 1100 V · CMC 97 µV/V CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 | |
| 35 | AC voltage / AC voltage meters and generators | Calibration – electrical quantities 40 Hz to 20 kHz — 1 mV to 10 mV · CMC 0,14 % 40 Hz to 20 kHz — 10 mV to 10 V · CMC 0,034 % 40 Hz to 20 kHz — 10 V to 100 V · CMC 0,040 % 40 Hz to 20 kHz — 100 V to 1000 V · CMC 0,080 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 | |
| 36 | AC current / AC current meters and generators | Calibration – electrical quantities 40 Hz to 1 kHz — 10 µA to 220 µA · CMC 0,026 % 40 Hz to 1 kHz — 220 µA to 22 mA · CMC 0,017 % 40 Hz to 1 kHz — 22 mA to 220 mA · CMC 0,016 % 40 Hz to 1 kHz — 220 mA to 2,2 A · CMC 0,033 % 40 Hz to 1 kHz — 2,2 A to 20 A · CMC 0,11 % 50 Hz to 1 kHz — 20 A to 120 A · CMC 0,11 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 37 | AC current / AC current meters and generators | Calibration – electrical quantities 45 Hz to 65 Hz — 120 A to 1000 A · CMC 0,67 % CMC for the field of measured quantity: Electrical quantities |
Calibrator generation with current simulation using a current coil | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 38 | AC current / AC current meters and generators | Calibration – electrical quantities 45 Hz to 5 kHz — 10 µA to 100 µA · CMC 0,11 % 45 Hz to 5 kHz — 100 µA to 100 mA · CMC 0,092 % 45 Hz to 5 kHz — 100 mA to 1 A · CMC 0,11 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 39 | AC current / AC current meters and generators | Calibration – electrical quantities 50 Hz to 1 kHz — 1 A to 100 A · CMC 0,14 % CMC for the field of measured quantity: Electrical quantities |
measurement with a multimeter on a current shunt | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 40 | Electrical power / power meters (50 Hz, up to 740 V) | Calibration – electrical quantities (0.011 to 11) A, cos φ = 1 — 0,1 kW to 37 kW · CMC 0,058 % (0.011 to 11) A, cos φ = 0.8 to 0.9 — 0,1 kW to 37 kW · CMC 0,093 % (0.011 to 11) A, cos φ = 0.1 to 0.7 — 0,1 kW to 37 kW · CMC 0,14 % (11 to 50) A, cos φ = 1 — 0,1 kW to 37 kW · CMC 0,075 % (11 to 50) A, cos φ = 0.8 to 0.9 — 0,1 kW to 37 kW · CMC 0,11 % (11 to 50) A, cos φ = 0.1 to 0.7 — 0,1 kW to 37 kW · CMC 0,16 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E14.0 | |
| 41 | Electrical power / power meters (50 Hz, up to 740 V) | Calibration – electrical quantities (50 to 1000) A, cos φ = 1 — 37 kW to 740 kW · CMC 0,76 % (50 to 1000) A, cos φ = 0.8 to 0.9 — 37 kW to 740 kW · CMC 0,77 % (50 to 1000) A, cos φ = 0.1 to 0.7 — 37 kW to 740 kW · CMC 0,78 % CMC for the field of measured quantity: Electrical quantities |
Calibrator generation with current simulation using a current coil | J 62.03.E14.0 | |
| 42 | pH / pH meters (only the electrical part of the instrument) | Calibration – electrical quantities 0 to 14 · CMC 0,001 CMC for the field of measured quantity: Electrical quantities |
Simulation of pH using voltage | J 62.03.Q01.0 | |
| 43 | Conductivity / conductivity meters (only the electrical part of the instrument) | Calibration – electrical quantities 0,1 µS to 1 µS · CMC 0,024 % 1 µS to 10 µS · CMC 0,012 % 10 µS to 100 mS · CMC 0,012 % 100 mS to 500 mS · CMC 0,058 % CMC for the field of measured quantity: Electrical quantities |
Simulation of conductivity using resistance | J 62.03.Q02.0 | |
| 44 | Measurement and simulation of temperature sensors / temperature gauges | Calibration – electrical quantities OST — 0 Ω to 100 Ω · CMC 20 mΩ OST — 100 Ω to 400 Ω · CMC 0,01 % + 10 mΩ OST — 400 Ω to 4000 Ω · CMC 0,015 % + 20 mΩ CMC for the field of measured quantity: Electrical quantities |
Direct resistance generation by a calibrator / resistance box | J 62.03.T07 | |
| 45 | Measurement and simulation of temperature sensors / temperature gauges | Calibration – electrical quantities TC — −10 mV to 60 mV · CMC 0,007 % + 4 µV CMC for the field of measured quantity: Electrical quantities |
Direct voltage generation by a calibrator | J 62.03.T07 | |
| 46 | Mains impedance / Inspection instruments | Calibration – electrical quantities 25 mΩ · CMC 5 mΩ 50 mΩ · CMC 5 mΩ 100 mΩ · CMC 5 mΩ 330 mΩ · CMC 7 mΩ 500 mΩ · CMC 8 mΩ 1 Ω · CMC 10 mΩ 1,8 Ω · CMC 18 mΩ 5 Ω · CMC 30 mΩ 10 Ω · CMC 60 mΩ 18 Ω · CMC 100 mΩ 50 Ω · CMC 300 mΩ 100 Ω · CMC 500 mΩ 180 Ω · CMC 1 Ω 500 Ω · CMC 2.5 Ω 1 kΩ · CMC 5 Ω 1,8 kΩ · CMC 10 Ω CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | 62.03.E15.0 kap. 7.3.6 | |
| 47 | Leakage current / Inspection instruments | Calibration – electrical quantities 0,1 mA to 1 mA · CMC 0,5 % 1 mA to 30 mA · CMC 0,32 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | 62.03.E15.0 kap. 7.3.7 | |
| 48 | Frequency / Electronic counters and generators | Calibration – time and frequency quantities 1 Hz to 100 Hz · CMC 2,5·10⁻⁶ Hz 100 Hz to 1 kHz · CMC 1,2·10⁻⁶ Hz 1 kHz to 10 kHz · CMC 1,5·10⁻⁶ Hz 10 kHz to 100 kHz · CMC 1,6·10⁻⁶ Hz 100 kHz to 1 MHz · CMC 3,6·10⁻⁵ Hz 1 MHz to 10 MHz · CMC 3,6·10⁻⁵ Hz 10 MHz to 100 MHz · CMC 1,5·10⁻⁴ Hz 100 MHz to 1 GHz · CMC 3,5·10⁻² Hz CMC for the field of measured quantity: Time and frequency quantities |
Direct generation (measurement) by a generator (counter) controlled from a GPS receiver | J 62.03.E06.0, J 62.03.E07.0 | |
| 49 | Time / Inspection equipment | Calibration – time and frequency quantities 10 ms to 50 ms · CMC 0,52 % 50 ms to 100 ms · CMC 0,27 % 100 ms to 500 ms · CMC 0,07 % 500 ms to 1 s · CMC 0,045 % 1 s to 5 s · CMC 0,025 % CMC for the field of measured quantity: Time and frequency quantities |
Direct generation with a calibrator | 62.03.E15.0 kap. 7.3.9 | |
| Nuclear Power Plant Temelín | |||||
| 50 | Micrometer gauges, micrometers for external measurement | Calibration – length 0 mm to 100 mm · CMC 0,0012 mm 100 mm to 500 mm · CMC 0,0013 mm 500 mm to 700 mm · CMC 0,0014 mm 700 mm to 900 mm · CMC 0,0015 mm 900 mm to 1 000 mm · CMC 0,0016 mm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | J 62.03.G01 | |
| 51 | Micrometers for internal measurement | Calibration – length 5 mm to 45 mm · CMC 0,0019 mm CMC for the field of measured quantity: Length |
Measurement by setting rings | J 62.03.G01 | |
| 52 | Three-contact internal gauges | Calibration – length 6 mm to 200 mm · CMC 0,0019 mm CMC for the field of measured quantity: Length |
Measurement by setting rings | J 62.03.G01 | |
| 53 | Slide gauges | Calibration – length 0 mm to 2 000 mm · CMC 0,012 mm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | J 62.03.G02 | |
| 54 | Indicators / dial, digital, lever | Calibration – length division 0.001 mm — 0 mm to 5 mm · CMC 0,00033 mm division 0.001 mm — 5 mm to 13 mm · CMC 0,00034 mm division 0.01 mm — 0 mm to 50 mm · CMC 0,0012 mm division 0.01 mm — 50 mm to 100 mm · CMC 0,0013 mm CMC for the field of measured quantity: Length |
Measurement on a dial indicator calibration instrument | J 62.03.G03 | |
| 55 | Weld gauges / linear scales | Calibration – length 0 mm to 50 mm · CMC 0,026 mm CMC for the field of measured quantity: Length |
Measuring with a slide gauge | J 62.03.G04 | |
| 56 | Weld gauges / linear scales | Calibration – length 50 mm to 60 mm · CMC 0,23 mm CMC for the field of measured quantity: Length |
Measurement using parallel gauge blocks | J 62.03.G04 | |
| 57 | Weld gauges / angular scales | Calibration – plane angle 0° to 90° · CMC 0,1° CMC for the field of measured quantity: Plane angle |
Measuring with an angle gauge | J 62.03.G04 | |
| 58 | Weld gauges / angular scales | Calibration – plane angle 90° to 150° · CMC 1,2° CMC for the field of measured quantity: Plane angle |
Measurement using angle gauges | J 62.03.G04 | |
| 59 | Scales with non-automatic function, electronic | Calibration – mass According to the weights used for calibration, Uᵢ can have the following values — 1 mg to 19 kg · CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg CMC for the field of measured quantity: Mass |
Load with standard weights (according to OIML R 111-1:2004) class E2 | J 62.06.W01 | |
| 60 | Effective value of linear harmonic mechanical vibrations / Vibrometers, vibration sensors | Calibration – mechanical motion acceleration; 30 Hz to 1 000 Hz — 3 m·s⁻² to 60 m·s⁻² · CMC 2,7 % velocity; 30 Hz to 1 000 Hz — 0,5 m·s⁻¹ to 320 m·s⁻¹ · CMC 2,7 % amplitude; 30 Hz to 1 000 Hz — 0 µm to 4800 µm · CMC 2,7 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference standard | J 62.09.V01 | |
| 61 | Sensitivity of vibration sensors | Calibration – mechanical motion 30 Hz to 1 000 Hz — 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² · CMC 2,7 % CMC for the field of measured quantity: Mechanical motion |
Comparison with a reference standard | J 62.09.V01 | |
| 62 | Torque / torque wrenches, torque screwdrivers | Calibration – torque 1 N·m to 1000 N·m · CMC 0,7 % CMC for the field of measured quantity: Torque |
Calibration with a reference torque device | J 62.03.S01 | |
| 63 | Deformation and digital manometers, pressure transducers including differential, pressure measuring chains | Calibration – pressure gas, absolute pressure — 0 kPa to 63 kPa · CMC 7,4 Pa gas, absolute pressure — 63 kPa to 7 MPa · CMC 0,007 % gas, gauge pressure — −100 kPa to −72 kPa · CMC 0,01 % gas, gauge pressure — −72 kPa to 0 kPa · CMC 8,5 Pa gas, gauge pressure — 16 kPa to 72 kPa · CMC 8,5 Pa gas, gauge pressure — 72 kPa to 7 MPa · CMC 0,007 % gas, barometric pressure — 70 kPa to 110 kPa · CMC 0,011 % CMC for the field of measured quantity: Pressure |
Comparison with a reference digital manometer | J62.03.P01, J62.03.P02, J62.03.P03 | |
| 64 | Deformation and digital manometers, pressure transducers including differential, pressure measuring chains | Calibration – pressure gas, gauge pressure — 0 Pa to 500 Pa · CMC 0,2 Pa gas, gauge pressure — 0,5 kPa to 16 kPa · CMC 0,027 % gas, gauge pressure — 7 MPa to 20 MPa · CMC 0,005 % gas, pressure difference at stat. pressure (0.1 to 20.1) MPa — 0 kPa to 500 kPa · CMC 0,014 % oil, gauge pressure, absolute pressure — 0 kPa to 350 kPa · CMC 0,042 kPa oil, gauge pressure, absolute pressure — 350 kPa to 3 MPa · CMC 0,009 % oil, gauge pressure, absolute pressure — 3 MPa to 10 MPa · CMC 0,46 kPa oil, gauge pressure, absolute pressure — 10 MPa to 100 MPa · CMC 0,005 % CMC for the field of measured quantity: Pressure |
Comparison with a standard piston pressure gauge | J62.03.P01, J62.03.P02, J62.03.P03 | |
| 65 | Resistance temperature sensors | Calibration – temperature 0,01 °C · CMC 0,01 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | J 62.03.T01 | |
| 66 | Resistance temperature sensors | Calibration – temperature −40 °C to 0 °C · CMC 0,02 °C 0 °C to 232 °C · CMC (5·10⁻⁵·t + 0,02) °C 232 °C to 400 °C · CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C to 550 °C · CMC (2·10⁻⁴·(t − 400) + 0,06) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T01 | |
| 67 | Glass thermometers | Calibration – temperature −40 °C to 100 °C · CMC 0,03 °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T03 | |
| 68 | Thermocouple temperature sensors | Calibration – temperature −40 °C to 0 °C · CMC 0,5 °C 0 °C to 400 °C · CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C to 550 °C · CMC (2·10⁻³·(t − 400) + 0,5) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T02 | |
| 69 | Temperature sensors with transducer | Calibration – temperature −40 °C to 0 °C · CMC 0,03 °C 0 °C to 400 °C · CMC (1·10⁻⁴·t + 0,03) °C 400 °C to 550 °C · CMC (4·10⁻⁴·(t − 400) + 0,07) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T06 | |
| 70 | Direct-indicating thermometers | Calibration – temperature 0,01 °C · CMC 0,004 °C CMC for the field of measured quantity: Temperature |
Direct measurement at triple point of water | J 62.03.T05 | |
| 71 | Direct-indicating thermometers | Calibration – temperature −40 °C to 0 °C · CMC 0,02 °C 0 °C to 400 °C · CMC (1·10⁻⁴·t + 0,02) °C 400 °C to 550 °C · CMC (2·10⁻⁴·(t − 400) + 0,06) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference resistance thermometer in a liquid bath | J 62.03.T05 | |
| 72 | Temperature measuring chains, including thermal sensors | Calibration – temperature −30 °C to 0 °C · CMC 0,1 °C 0 °C to 400 °C · CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C to 660 °C · CMC 1,5·10⁻³·(t − 400) + 0,2) °C CMC for the field of measured quantity: Temperature |
Comparison with a reference electronic thermometer in a vertical furnace | J 62.03.T05 | |
| 73 | DC voltage / DC voltage meters and generators | Calibration – electrical quantities 0 mV to 220 mV · CMC 11 µV/V + 0,4 µV 220 mV to 2,2 V · CMC 6,4 µV/V 2,2 V to 11 V · CMC 4,9 µV/V 11 V to 22 V · CMC 4,7 µV/V 22 V to 220 V · CMC 6,4 µV/V 220 V to 1100 V · CMC 8,5 µV/V CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 | |
| 74 | DC voltage / DC voltage meters and generators | Calibration – electrical quantities 0 mV to 100 mV · CMC 9 µV/V + 0,3 µV 100 mV to 1 V · CMC 6,2 µV/V 1 V to 10 V · CMC 5,4 µV/V 10 V to 1000 V · CMC 8,2 µV/V CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 | |
| 75 | DC current / DC current meters and generators | Calibration – electrical quantities 0 µA to 220 µA · CMC 80 µA/A + 6 nA 220 µA to 2,2 mA · CMC 46 µA/A 2,2 mA to 22 mA · CMC 44 µA/A 22 mA to 220 mA · CMC 57 µA/A 220 mA to 2,2 A · CMC 0,01 % 2,2 A to 20 A · CMC 0,048 % 20 A to 120 A · CMC 0,035 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 76 | DC current / DC current meters and generators | Calibration – electrical quantities 120 A to 1000 A · CMC 0,65 % CMC for the field of measured quantity: Electrical quantities |
Calibrator generation with current simulation using a current coil | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 77 | DC current / DC current meters and generators | Calibration – electrical quantities 0 µA to 10 µA · CMC 0,018 % + 1,2 nA 10 µA to 100 µA · CMC 63 µA/A 100 µA to 1 mA · CMC 39 µA/A 1 mA to 10 mA · CMC 38 µA/A 10 mA to 100 mA · CMC 54 µA/A 100 mA to 1 A · CMC 0,015 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 78 | DC current / DC current meters and generators | Calibration – electrical quantities 1 A to 20 A · CMC 0,024 % 20 A to 100 A · CMC 0,058 % CMC for the field of measured quantity: Electrical quantities |
Measurement with a multimeter on a current shunt | J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 | |
| 79 | DC resistance / DC resistance meters and generators | Calibration – electrical quantities 0 Ω · CMC 50 µΩ 0,01 Ω to 0,1 Ω · CMC 1 % 0,1 Ω to 1 Ω · CMC 0,2 % 1 Ω to 10 Ω · CMC 0,05 % 10 Ω to 100 kΩ · CMC 0,01 % 100 kΩ to 1 MΩ · CMC 0,02 % 1 MΩ to 10 MΩ · CMC 0,05 % 10 MΩ to 100 MΩ · CMC 0,1 % 100 MΩ to 100 GΩ · CMC 1 % 100 GΩ to 1000 GΩ · CMC 4 % 1 mΩ · CMC 0,01 % 10 mΩ · CMC 0,01 % 100 mΩ · CMC 0,01 % 1 Ω · CMC 0,01 % 1,9 Ω · CMC 0,011 % 10 Ω · CMC 27 µΩ/Ω 19 Ω · CMC 27 µΩ/Ω 100 Ω · CMC 12 µΩ/Ω 190 Ω · CMC 12 µΩ/Ω 1 kΩ · CMC 8 µΩ/Ω 1,9 kΩ · CMC 8 µΩ/Ω 10 kΩ · CMC 8 µΩ/Ω 19 kΩ · CMC 8 µΩ/Ω 100 kΩ · CMC 10 µΩ/Ω 190 kΩ · CMC 12 µΩ/Ω 1 MΩ · CMC 15 µΩ/Ω 1,9 MΩ · CMC 21 µΩ/Ω 10 MΩ · CMC 46 µΩ/Ω 19 MΩ · CMC 55 µΩ/Ω 100 MΩ · CMC 0,012 % 10 GΩ · CMC 0,2 % CMC for the field of measured quantity: Electrical quantities |
Direct generation by calibrator / reference resistors / resistance boxes | J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 | |
| 80 | DC resistance / DC resistance meters and generators | Calibration – electrical quantities 0,01 Ω to 10 Ω · CMC 27 µΩ/Ω 10 Ω to 100 Ω · CMC 22 µΩ/Ω 100 Ω to 10 kΩ · CMC 14 µΩ/Ω 10 kΩ to 100 kΩ · CMC 15 µΩ/Ω 100 kΩ to 1 MΩ · CMC 26 µΩ/Ω 1 MΩ to 10 MΩ · CMC 77 µΩ/Ω 10 MΩ to 100 MΩ · CMC 0,064 % 100 MΩ to 1 GΩ · CMC 0,58 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 | |
| 81 | AC voltage / AC voltage meters and generators | Calibration – electrical quantities 40 Hz to 20 kHz — 1 mV to 22 mV · CMC 0,41 % 40 Hz to 20 kHz — 22 mV to 220 mV · CMC 0,038 % 40 Hz to 20 kHz — 220 mV to 2,2 V · CMC 0,015 % 40 Hz to 20 kHz — 2,2 V to 11 V · CMC 59 µV/V 40 Hz to 20 kHz — 11 V to 22 V · CMC 57 µV/V 40 Hz to 20 kHz — 22 V to 220 V · CMC 65 µV/V 50 Hz to 1 kHz — 220 V to 1100 V · CMC 97 µV/V CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 | |
| 82 | AC voltage / AC voltage meters and generators | Calibration – electrical quantities 40 Hz to 20 kHz — 1 mV to 10 mV · CMC 0,14 % 40 Hz to 20 kHz — 10 mV to 10 V · CMC 0,034 % 40 Hz to 20 kHz — 10 V to 100 V · CMC 0,040 % 40 Hz to 20 kHz — 100 V to 1000 V · CMC 0,080 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 | |
| 83 | AC current / AC current meters and generators | Calibration – electrical quantities 40 Hz to 1 kHz — 10 µA to 220 µA · CMC 0,026 % 40 Hz to 1 kHz — 220 µA to 22 mA · CMC 0,017 % 40 Hz to 1 kHz — 22 mA to 220 mA · CMC 0,016 % 40 Hz to 1 kHz — 220 mA to 2,2 A · CMC 0,033 % 40 Hz to 1 kHz — 2,2 A to 20 A · CMC 0,11 % 50 Hz to 1 kHz — 20 A to 120 A · CMC 0,11 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 84 | AC current / AC current meters and generators | Calibration – electrical quantities 45 Hz to 65 Hz — 120 A to 1000 A · CMC 0,67 % CMC for the field of measured quantity: Electrical quantities |
Calibrator generation with current simulation using a current coil | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 85 | AC current / AC current meters and generators | Calibration – electrical quantities 45 Hz to 5 kHz — 10 µA to 100 µA · CMC 0,11 % 45 Hz to 5 kHz — 100 µA to 100 mA · CMC 0,092 % 45 Hz to 5 kHz — 100 mA to 1 A · CMC 0,11 % CMC for the field of measured quantity: Electrical quantities |
Direct measurement using a multimeter | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 86 | AC current / AC current meters and generators | Calibration – electrical quantities 50 Hz to 1 kHz — 1 A to 100 A · CMC 0,14 % CMC for the field of measured quantity: Electrical quantities |
measurement with a multimeter on a current shunt | J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 | |
| 87 | pH / pH meters (only the electrical part of the instrument) | Calibration – electrical quantities 0 to 14 · CMC 0,001 CMC for the field of measured quantity: Electrical quantities |
Simulation of pH using voltage | J 62.03.Q01.0 | |
| 88 | Conductivity / conductivity meters (only the electrical part of the instrument) | Calibration – electrical quantities 0,1 µS to 1 µS · CMC 0,024 % 1 µS to 10 µS · CMC 0,012 % 10 µS to 100 mS · CMC 0,012 % 100 mS to 500 mS · CMC 0,058 % CMC for the field of measured quantity: Electrical quantities |
Simulation of conductivity using resistance | J 62.03.Q02.0 | |
| 89 | Measurement and simulation of temperature sensors / temperature gauges | Calibration – electrical quantities OST — 0 Ω to 100 Ω · CMC 20 mΩ OST — 100 Ω to 400 Ω · CMC 0,01 % + 10 mΩ OST — 400 Ω to 4000 Ω · CMC 0,015 % + 20 mΩ CMC for the field of measured quantity: Electrical quantities |
Direct resistance generation by a calibrator / resistance box | J 62.03.T07 | |
| 90 | Measurement and simulation of temperature sensors / temperature gauges | Calibration – electrical quantities TC — −10 mV to 60 mV · CMC 0,007 % + 4 µV CMC for the field of measured quantity: Electrical quantities |
Direct voltage generation by a calibrator | J 62.03.T07 | |
| 91 | Mains impedance / Inspection instruments | Calibration – electrical quantities 25 mΩ · CMC 5 mΩ 50 mΩ · CMC 5 mΩ 100 mΩ · CMC 5 mΩ 330 mΩ · CMC 7 mΩ 500 mΩ · CMC 8 mΩ 1 Ω · CMC 10 mΩ 1,8 Ω · CMC 18 mΩ 5 Ω · CMC 30 mΩ 10 Ω · CMC 60 mΩ 18 Ω · CMC 100 mΩ 50 Ω · CMC 300 mΩ 100 Ω · CMC 500 mΩ 180 Ω · CMC 1 Ω 500 Ω · CMC 2.5 Ω 1 kΩ · CMC 5 Ω 1,8 kΩ · CMC 10 Ω CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | 62.03.E15.0 kap. 7.3.6 | |
| 92 | Leakage current / Inspection instruments | Calibration – electrical quantities 0,1 mA to 1 mA · CMC 0,5 % 1 mA to 30 mA · CMC 0,32 % CMC for the field of measured quantity: Electrical quantities |
Direct generation with a calibrator | 62.03.E15.0 kap. 7.3.7 | |
| 93 | Time / Inspection equipment | Calibration – time and frequency quantities 10 ms to 50 ms · CMC 0,52 % 50 ms to 100 ms · CMC 0,27 % 100 ms to 500 ms · CMC 0,07 % 500 ms to 1 s · CMC 0,045 % 1 s to 5 s · CMC 0,025 % CMC for the field of measured quantity: Time and frequency quantities |
Direct generation with a calibrator | 62.03.E15.0 kap. 7.3.9 | |
Reference standards (37)
62.03.E15.0
J 62.03.E01.0
J 62.03.E02.0
J 62.03.E03.0
J 62.03.E04.0
J 62.03.E05.0
J 62.03.E06.0
J 62.03.E07.0
J 62.03.E08.0
J 62.03.E09.0
J 62.03.E10.0
J 62.03.E11.0
J 62.03.E12.0
J 62.03.E13.0
J 62.03.E14.0
J 62.03.E15.0
J 62.03.G01
J 62.03.G02
J 62.03.G03
J 62.03.G04
J 62.03.M01
J 62.03.Q01.0
J 62.03.Q02.0
J 62.03.S01
J 62.03.T01
J 62.03.T02
J 62.03.T03
J 62.03.T04
J 62.03.T05
J 62.03.T06
J 62.03.T07
J 62.03.W02
J 62.06.W01
J 62.09.V01
J62.03.P01
J62.03.P02
J62.03.P03