{"lab":{"_id":"6ade8b29ff068247617080fc","accr_number":"2245","country":"CZ","accr_body":"ČIA","address":"JE Temelín, 373 05 Temelín","categories":["metrology"],"city":"Temelín","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[14.3812639,49.1805919]},"map_coord":[49.1805919,14.3812639],"map_geo":"cai-mapa","methods_count":93,"name":"ČEZ, a. s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie w dziedzinach: długość, kąt płaski, masa, moment siły, ciśnienie, temperatura, wilgotność, wielkości elektryczne, wielkości czasu i częstotliwości oraz ruch mechaniczny, w zakresie określonym w załączniku do świadectwa.","search_text":"čez, a. s. je temelín, 373 05 temelín 2245","source_page_url":"https://www.cai.cz/?subjekt=2245-cez-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"18-01-2029","website":"www.cez.cz/akl","certificate_date":"11.09.2026","certificate_no":"429/2026","certificate_replaces":"368/2025 z 17.07.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie w dziedzinach: długość, kąt płaski, masa, moment siły, ciśnienie, temperatura, wilgotność, wielkości elektryczne, wielkości czasu i częstotliwości oraz ruch mechaniczny, w zakresie określonym w załączniku do świadectwa.","en":"Calibration in the fields of length, plane angle, mass, torque, pressure, temperature, humidity, electrical quantities, time and frequency quantities and mechanical motion to the extent as specified in the appendix to this Certificate.","zh":"长度、平面角、质量、扭矩、压力、温度、湿度、电学量、时间和频率量以及机械运动领域的校准，范围见本证书附件。","cs":"Kalibrace v oborech délky, rovinného úhlu, hmotnosti, momentu síly, tlaku, teploty, vlhkosti, elektrických veličin, veličin času a frekvence a mechanického pohybu, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące – metrologia","lab_division_cs":"Kalibrační laboratoř – metrologie","lab_division_en":"Calibration Laboratory – Metrology","lab_division_zh":"校准实验室 – 计量","lab_locations":[{"code":null,"name":"ČEZ, a. s.","street":"JE Temelín","postal_code":"373 05","city":"Temelín","is_hq":true,"address":"JE Temelín, 373 05 Temelín","site":"37305|jetemelín"},{"code":null,"name":"Elektrownia jądrowa Dukovany","street":"Modřínová 1094","postal_code":"674 01","city":"Třebíč","is_hq":false,"address":"Modřínová 1094, 674 01 Třebíč","site":"67401|modřínová1094"},{"code":null,"name":"Elektrownia jądrowa Temelín","street":"","postal_code":"373 05","city":"Temelín","is_hq":false,"address":"373 05 Temelín","site":"37305|"}],"lab_locations_en":[{"code":null,"name":"ČEZ, a. s.","street":"JE Temelín","postal_code":"373 05","city":"Temelín","is_hq":true,"address":"JE Temelín, 373 05 Temelín","site":"37305|jetemelín"},{"code":null,"name":"Nuclear Power Plant Dukovany","street":"Modřínová 1094","postal_code":"674 01","city":"Třebíč","is_hq":false,"address":"Modřínová 1094, 674 01 Třebíč","site":"67401|modřínová1094"},{"code":null,"name":"Nuclear Power Plant Temelín","street":"","postal_code":"373 05","city":"Temelín","is_hq":false,"address":"373 05 Temelín","site":"37305|"}],"lab_locations_zh":[{"code":null,"name":"ČEZ, a. s.","street":"JE Temelín","postal_code":"373 05","city":"Temelín","is_hq":true,"address":"JE Temelín, 373 05 Temelín","site":"37305|jetemelín"},{"code":null,"name":"杜科瓦尼核电站","street":"Modřínová 1094","postal_code":"674 01","city":"Třebíč","is_hq":false,"address":"Modřínová 1094, 674 01 Třebíč","site":"67401|modřínová1094"},{"code":null,"name":"泰梅林核电站","street":"","postal_code":"373 05","city":"Temelín","is_hq":false,"address":"373 05 Temelín","site":"37305|"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"OST","pl":"rezystancyjny czujnik temperatury. Dla platynowego rezystancyjnego czujnika temperatury o współczynniku temperaturowym α = 0,003855 °C⁻¹ do przeliczenia stosuje się charakterystykę i stałe z tej normy. Dla pozostałych czujników – o innej rezystancji podstawowej i innym współczynniku temperaturowym, a także z innego materiału rezystora pomiarowego, np. Ni lub Cu – przy przeliczeniach stosuje się odpowiednie normy lub specyfikację producenta danego czujnika – charakterystykę, stałe, współczynnik czułości (°C/Ω).","en":"RTD – resistance temperature detector. For a platinum resistance temperature detector with a temperature coefficient of α = 0.003855 °C⁻¹, the characteristics and constants specified in this standard shall be used for conversion. For other RTDs – with a different initial resistance and temperature coefficient, as well as those made of a different measuring resistor material, such as Ni or Cu – the relevant standards or the manufacturer’s specifications for the given sensor – characteristics, constants, sensitivity coefficient (°C/Ω) – shall be used for conversions.","zh":"电阻式温度传感器。对于温度系数 α = 0,003855 °C⁻¹ 的铂电阻温度传感器，换算时采用该标准规定的特性和常数。对于其他电阻式温度传感器——具有不同基础电阻和温度系数，或测量电阻材料不同（如 Ni 或 Cu）——换算时采用相应标准或该传感器制造商的规格——特性、常数、灵敏度系数 (°C/Ω)。","cs":"odporový snímač teploty. Pro platinový odporový snímač teploty s teplotním koeficientem α = 0,003855 °C⁻¹ se použije pro přepočet charakteristika a konstanty z této normy. Pro ostatní OST – s jiným základním odporem a teplotním koeficientem, a dále pak s jiným materiálem měřicího odporu, např. Ni nebo Cu se při přepočtech použijí příslušné normy nebo specifikaci výrobce k danému snímači – charakteristika, konstanty, citlivostní koeficient (°C/Ω)."},{"abbr":"TC","pl":"termopara. Przy stosowaniu wewnętrznej kompensacji zimnego końca do najmniejszej niepewności należy dodać jeszcze 0,15 °C. Dla termopar wymienionych w normie ČSN EN 60584-1 ed. 2 do przeliczenia stosuje się charakterystyki i stałe z tej normy. Dla pozostałych, niewymienionych w tej normie, przy przeliczeniach należy stosować odpowiednie normy lub specyfikację producenta danego czujnika – charakterystykę, stałe, współczynnik czułości (°C/µV).","en":"TC – thermocouple. When using internal cold-junction compensation, 0.15 °C must be added to the lowest uncertainty. For TCs listed in the ČSN EN 60584-1, 2nd edition, the characteristics and constants from this standard shall be used for conversion. For others not listed in this standard, the relevant standards or the manufacturer’s specifications for the given sensor – characteristics, constants, sensitivity coefficient (°C/µV) – must be used for conversions.","zh":"热电偶。使用内部冷端补偿时，最低不确定度还须加上 0,15 °C。对于 ČSN EN 60584-1 第2版所列热电偶，换算时采用该标准的特性和常数。对于该标准未列出的其他热电偶，换算时须采用相应标准或该传感器制造商的规格——特性、常数、灵敏度系数 (°C/µV)。","cs":"termoelektrický článek. Při použití vnitřní kompenzace studeného konce je třeba k nejnižší nejistotě ještě přičíst 0,15 °C. Pro TC uvedené v normě ČSN EN 60584-1 ed. 2 se použijí pro přepočet charakteristiky a konstanty z této normy. Pro ostatní, které v této normě uvedeny nejsou, je třeba při přepočtech použít příslušné normy nebo specifikaci výrobce k danému snímači – charakteristika, konstanty, citlivostní koeficient (°C/µV)."}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"d83eff6e38b40a06f29869f812c7ecdf92aa958d78d64ef14b14e5fb5566dc2e","source_pdf_url":"https://www.cai.cz/OA/pdf/429_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/429_2026_EN.pdf"},"methods":[{"_id":"8214837b6aa8272111358516","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy mikrometryczne, mikrometry do pomiarów zewnętrznych","test_object_en":"Micrometer gauges, micrometers for external measurement","test_object_zh":"测微量具、外径千分尺","test_object_cs":"Mikrometrická měřidla, mikrometry pro vnější měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,0012 mm"},{"name":"","range":"od 100 mm do 500 mm","cmc":"0,0013 mm"},{"name":"","range":"od 500 mm do 700 mm","cmc":"0,0014 mm"},{"name":"","range":"od 700 mm do 900 mm","cmc":"0,0015 mm"},{"name":"","range":"od 900 mm do 1 000 mm","cmc":"0,0016 mm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,0012 mm"},{"name":"","range":"100 mm to 500 mm","cmc":"0,0013 mm"},{"name":"","range":"500 mm to 700 mm","cmc":"0,0014 mm"},{"name":"","range":"700 mm to 900 mm","cmc":"0,0015 mm"},{"name":"","range":"900 mm to 1 000 mm","cmc":"0,0016 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,0012 mm"},{"name":"","range":"100 mm 至 500 mm","cmc":"0,0013 mm"},{"name":"","range":"500 mm 至 700 mm","cmc":"0,0014 mm"},{"name":"","range":"700 mm 至 900 mm","cmc":"0,0015 mm"},{"name":"","range":"900 mm 至 1 000 mm","cmc":"0,0016 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,0012 mm"},{"name":"","range":"100 mm až 500 mm","cmc":"0,0013 mm"},{"name":"","range":"500 mm až 700 mm","cmc":"0,0014 mm"},{"name":"","range":"700 mm až 900 mm","cmc":"0,0015 mm"},{"name":"","range":"900 mm až 1 000 mm","cmc":"0,0016 mm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 100 mm CMC 0,0012 mm\nod 100 mm do 500 mm CMC 0,0013 mm\nod 500 mm do 700 mm CMC 0,0014 mm\nod 700 mm do 900 mm CMC 0,0015 mm\nod 900 mm do 1 000 mm CMC 0,0016 mm\nPomiar za pomocą płytek wzorcowych","reference":"J 62.03.G01","norm_bases":["J 62.03.G01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne, mikrometry do pomiarów zewnętrznych Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 100 mm CMC 0,0012 mm od 100 mm do 500 mm CMC 0,0013 mm od 500 mm do 700 mm CMC 0,0014 mm od 700 mm do 900 mm CMC 0,0015 mm od 900 mm do 1 000 mm CMC 0,0016 mm Mikrometrická měřidla, mikrometry pro vnější měření Kalibrace – délka Měření pomocí koncových měrek 0 mm až 100 mm CMC 0,0012 mm 100 mm až 500 mm CMC 0,0013 mm 500 mm až 700 mm CMC 0,0014 mm 700 mm až 900 mm CMC 0,0015 mm 900 mm až 1 000 mm CMC 0,0016 mm J 62.03.G01 Przyrzady mikrometryczne, mikrometry do pomiarow zewnetrznych Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 100 mm CMC 0,0012 mm od 100 mm do 500 mm CMC 0,0013 mm od 500 mm do 700 mm CMC 0,0014 mm od 700 mm do 900 mm CMC 0,0015 mm od 900 mm do 1 000 mm CMC 0,0016 mm Mikrometricka meridla, mikrometry pro vnejsi mereni Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 100 mm CMC 0,0012 mm 100 mm az 500 mm CMC 0,0013 mm 500 mm az 700 mm CMC 0,0014 mm 700 mm az 900 mm CMC 0,0015 mm 900 mm az 1 000 mm CMC 0,0016 mm J 62.03.G01","search_en":"Micrometer gauges, micrometers for external measurement Calibration – length Measurement using parallel gauge blocks 0 mm to 100 mm CMC 0,0012 mm 100 mm to 500 mm CMC 0,0013 mm 500 mm to 700 mm CMC 0,0014 mm 700 mm to 900 mm CMC 0,0015 mm 900 mm to 1 000 mm CMC 0,0016 mm J 62.03.G01","search_zh":"测微量具、外径千分尺 校准 – 长度 用量块测量 0 mm 至 100 mm CMC 0,0012 mm 100 mm 至 500 mm CMC 0,0013 mm 500 mm 至 700 mm CMC 0,0014 mm 700 mm 至 900 mm CMC 0,0015 mm 900 mm 至 1 000 mm CMC 0,0016 mm J 62.03.G01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cdd2d0ba1bb804079e8ae554","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Przyrządy mikrometryczne, mikrometry do pomiarów zewnętrznych","test_object_en":"Micrometer gauges, micrometers for external measurement","test_object_zh":"测微量具、外径千分尺","test_object_cs":"Mikrometrická měřidla, mikrometry pro vnější měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 100 mm","cmc":"0,0012 mm"},{"name":"","range":"od 100 mm do 500 mm","cmc":"0,0013 mm"},{"name":"","range":"od 500 mm do 700 mm","cmc":"0,0014 mm"},{"name":"","range":"od 700 mm do 900 mm","cmc":"0,0015 mm"},{"name":"","range":"od 900 mm do 1 000 mm","cmc":"0,0016 mm"}],"parameters_en":[{"name":"","range":"0 mm to 100 mm","cmc":"0,0012 mm"},{"name":"","range":"100 mm to 500 mm","cmc":"0,0013 mm"},{"name":"","range":"500 mm to 700 mm","cmc":"0,0014 mm"},{"name":"","range":"700 mm to 900 mm","cmc":"0,0015 mm"},{"name":"","range":"900 mm to 1 000 mm","cmc":"0,0016 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 100 mm","cmc":"0,0012 mm"},{"name":"","range":"100 mm 至 500 mm","cmc":"0,0013 mm"},{"name":"","range":"500 mm 至 700 mm","cmc":"0,0014 mm"},{"name":"","range":"700 mm 至 900 mm","cmc":"0,0015 mm"},{"name":"","range":"900 mm 至 1 000 mm","cmc":"0,0016 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 100 mm","cmc":"0,0012 mm"},{"name":"","range":"100 mm až 500 mm","cmc":"0,0013 mm"},{"name":"","range":"500 mm až 700 mm","cmc":"0,0014 mm"},{"name":"","range":"700 mm až 900 mm","cmc":"0,0015 mm"},{"name":"","range":"900 mm až 1 000 mm","cmc":"0,0016 mm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\nod 0 mm do 100 mm CMC 0,0012 mm\nod 100 mm do 500 mm CMC 0,0013 mm\nod 500 mm do 700 mm CMC 0,0014 mm\nod 700 mm do 900 mm CMC 0,0015 mm\nod 900 mm do 1 000 mm CMC 0,0016 mm\nPomiar za pomocą płytek wzorcowych","reference":"J 62.03.G01","norm_bases":["J 62.03.G01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przyrządy mikrometryczne, mikrometry do pomiarów zewnętrznych Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 100 mm CMC 0,0012 mm od 100 mm do 500 mm CMC 0,0013 mm od 500 mm do 700 mm CMC 0,0014 mm od 700 mm do 900 mm CMC 0,0015 mm od 900 mm do 1 000 mm CMC 0,0016 mm Mikrometrická měřidla, mikrometry pro vnější měření Kalibrace – délka Měření pomocí koncových měrek 0 mm až 100 mm CMC 0,0012 mm 100 mm až 500 mm CMC 0,0013 mm 500 mm až 700 mm CMC 0,0014 mm 700 mm až 900 mm CMC 0,0015 mm 900 mm až 1 000 mm CMC 0,0016 mm J 62.03.G01 Przyrzady mikrometryczne, mikrometry do pomiarow zewnetrznych Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 100 mm CMC 0,0012 mm od 100 mm do 500 mm CMC 0,0013 mm od 500 mm do 700 mm CMC 0,0014 mm od 700 mm do 900 mm CMC 0,0015 mm od 900 mm do 1 000 mm CMC 0,0016 mm Mikrometricka meridla, mikrometry pro vnejsi mereni Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 100 mm CMC 0,0012 mm 100 mm az 500 mm CMC 0,0013 mm 500 mm az 700 mm CMC 0,0014 mm 700 mm az 900 mm CMC 0,0015 mm 900 mm az 1 000 mm CMC 0,0016 mm J 62.03.G01","search_en":"Micrometer gauges, micrometers for external measurement Calibration – length Measurement using parallel gauge blocks 0 mm to 100 mm CMC 0,0012 mm 100 mm to 500 mm CMC 0,0013 mm 500 mm to 700 mm CMC 0,0014 mm 700 mm to 900 mm CMC 0,0015 mm 900 mm to 1 000 mm CMC 0,0016 mm J 62.03.G01","search_zh":"测微量具、外径千分尺 校准 – 长度 用量块测量 0 mm 至 100 mm CMC 0,0012 mm 100 mm 至 500 mm CMC 0,0013 mm 500 mm 至 700 mm CMC 0,0014 mm 700 mm 至 900 mm CMC 0,0015 mm 900 mm 至 1 000 mm CMC 0,0016 mm J 62.03.G01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b9a2866f2d3eaf562f06aef","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Mikrometry do pomiarów wewnętrznych","test_object_en":"Micrometers for internal measurement","test_object_zh":"内径千分尺","test_object_cs":"Mikrometry pro vnitřní měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 5 mm do 45 mm","cmc":"0,0019 mm"}],"parameters_en":[{"name":"","range":"5 mm to 45 mm","cmc":"0,0019 mm"}],"parameters_zh":[{"name":"","range":"5 mm 至 45 mm","cmc":"0,0019 mm"}],"parameters_cs":[{"name":"","range":"5 mm až 45 mm","cmc":"0,0019 mm"}],"technique":"Pomiar za pomocą pierścieni nastawczych","technique_en":"Measurement by setting rings","technique_zh":"用校对环规测量","technique_cs":"Měření pomocí nástavných kroužků","techniques":["Pomiar za pomocą pierścieni nastawczych"],"techniques_en":["Measurement by setting rings"],"techniques_zh":["用校对环规测量"],"techniques_cs":["Měření pomocí nástavných kroužků"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 5 mm do 45 mm CMC 0,0019 mm\nPomiar za pomocą pierścieni nastawczych","reference":"J 62.03.G01","norm_bases":["J 62.03.G01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mikrometry do pomiarów wewnętrznych Wzorcowanie – długość Pomiar za pomocą pierścieni nastawczych od 5 mm do 45 mm CMC 0,0019 mm Mikrometry pro vnitřní měření Kalibrace – délka Měření pomocí nástavných kroužků 5 mm až 45 mm CMC 0,0019 mm J 62.03.G01 Mikrometry do pomiarow wewnetrznych Wzorcowanie – dlugosc Pomiar za pomoca pierscieni nastawczych od 5 mm do 45 mm CMC 0,0019 mm Mikrometry pro vnitrni mereni Kalibrace – delka Mereni pomoci nastavnych krouzku 5 mm az 45 mm CMC 0,0019 mm J 62.03.G01","search_en":"Micrometers for internal measurement Calibration – length Measurement by setting rings 5 mm to 45 mm CMC 0,0019 mm J 62.03.G01","search_zh":"内径千分尺 校准 – 长度 用校对环规测量 5 mm 至 45 mm CMC 0,0019 mm J 62.03.G01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"21468f45b0c15cb930ddfbe3","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Mikrometry do pomiarów wewnętrznych","test_object_en":"Micrometers for internal measurement","test_object_zh":"内径千分尺","test_object_cs":"Mikrometry pro vnitřní měření","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 5 mm do 45 mm","cmc":"0,0019 mm"}],"parameters_en":[{"name":"","range":"5 mm to 45 mm","cmc":"0,0019 mm"}],"parameters_zh":[{"name":"","range":"5 mm 至 45 mm","cmc":"0,0019 mm"}],"parameters_cs":[{"name":"","range":"5 mm až 45 mm","cmc":"0,0019 mm"}],"technique":"Pomiar za pomocą pierścieni nastawczych","technique_en":"Measurement by setting rings","technique_zh":"用校对环规测量","technique_cs":"Měření pomocí nástavných kroužků","techniques":["Pomiar za pomocą pierścieni nastawczych"],"techniques_en":["Measurement by setting rings"],"techniques_zh":["用校对环规测量"],"techniques_cs":["Měření pomocí nástavných kroužků"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 5 mm do 45 mm CMC 0,0019 mm\nPomiar za pomocą pierścieni nastawczych","reference":"J 62.03.G01","norm_bases":["J 62.03.G01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mikrometry do pomiarów wewnętrznych Wzorcowanie – długość Pomiar za pomocą pierścieni nastawczych od 5 mm do 45 mm CMC 0,0019 mm Mikrometry pro vnitřní měření Kalibrace – délka Měření pomocí nástavných kroužků 5 mm až 45 mm CMC 0,0019 mm J 62.03.G01 Mikrometry do pomiarow wewnetrznych Wzorcowanie – dlugosc Pomiar za pomoca pierscieni nastawczych od 5 mm do 45 mm CMC 0,0019 mm Mikrometry pro vnitrni mereni Kalibrace – delka Mereni pomoci nastavnych krouzku 5 mm az 45 mm CMC 0,0019 mm J 62.03.G01","search_en":"Micrometers for internal measurement Calibration – length Measurement by setting rings 5 mm to 45 mm CMC 0,0019 mm J 62.03.G01","search_zh":"内径千分尺 校准 – 长度 用校对环规测量 5 mm 至 45 mm CMC 0,0019 mm J 62.03.G01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77c50b95e7aeacd001ea5e79","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Średnicówki trójpunktowe","test_object_en":"Three-contact internal gauges","test_object_zh":"三点式内径表","test_object_cs":"Třídotekové dutinoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 6 mm do 200 mm","cmc":"0,0019 mm"}],"parameters_en":[{"name":"","range":"6 mm to 200 mm","cmc":"0,0019 mm"}],"parameters_zh":[{"name":"","range":"6 mm 至 200 mm","cmc":"0,0019 mm"}],"parameters_cs":[{"name":"","range":"6 mm až 200 mm","cmc":"0,0019 mm"}],"technique":"Pomiar za pomocą pierścieni nastawczych","technique_en":"Measurement by setting rings","technique_zh":"用校对环规测量","technique_cs":"Měření pomocí nástavných kroužků","techniques":["Pomiar za pomocą pierścieni nastawczych"],"techniques_en":["Measurement by setting rings"],"techniques_zh":["用校对环规测量"],"techniques_cs":["Měření pomocí nástavných kroužků"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 6 mm do 200 mm CMC 0,0019 mm\nPomiar za pomocą pierścieni nastawczych","reference":"J 62.03.G01","norm_bases":["J 62.03.G01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki trójpunktowe Wzorcowanie – długość Pomiar za pomocą pierścieni nastawczych od 6 mm do 200 mm CMC 0,0019 mm Třídotekové dutinoměry Kalibrace – délka Měření pomocí nástavných kroužků 6 mm až 200 mm CMC 0,0019 mm J 62.03.G01 Srednicowki trojpunktowe Wzorcowanie – dlugosc Pomiar za pomoca pierscieni nastawczych od 6 mm do 200 mm CMC 0,0019 mm Tridotekove dutinomery Kalibrace – delka Mereni pomoci nastavnych krouzku 6 mm az 200 mm CMC 0,0019 mm J 62.03.G01","search_en":"Three-contact internal gauges Calibration – length Measurement by setting rings 6 mm to 200 mm CMC 0,0019 mm J 62.03.G01","search_zh":"三点式内径表 校准 – 长度 用校对环规测量 6 mm 至 200 mm CMC 0,0019 mm J 62.03.G01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"33914119c6e52cc9a0d3516f","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Średnicówki trójpunktowe","test_object_en":"Three-contact internal gauges","test_object_zh":"三点式内径表","test_object_cs":"Třídotekové dutinoměry","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 6 mm do 200 mm","cmc":"0,0019 mm"}],"parameters_en":[{"name":"","range":"6 mm to 200 mm","cmc":"0,0019 mm"}],"parameters_zh":[{"name":"","range":"6 mm 至 200 mm","cmc":"0,0019 mm"}],"parameters_cs":[{"name":"","range":"6 mm až 200 mm","cmc":"0,0019 mm"}],"technique":"Pomiar za pomocą pierścieni nastawczych","technique_en":"Measurement by setting rings","technique_zh":"用校对环规测量","technique_cs":"Měření pomocí nástavných kroužků","techniques":["Pomiar za pomocą pierścieni nastawczych"],"techniques_en":["Measurement by setting rings"],"techniques_zh":["用校对环规测量"],"techniques_cs":["Měření pomocí nástavných kroužků"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 6 mm do 200 mm CMC 0,0019 mm\nPomiar za pomocą pierścieni nastawczych","reference":"J 62.03.G01","norm_bases":["J 62.03.G01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Średnicówki trójpunktowe Wzorcowanie – długość Pomiar za pomocą pierścieni nastawczych od 6 mm do 200 mm CMC 0,0019 mm Třídotekové dutinoměry Kalibrace – délka Měření pomocí nástavných kroužků 6 mm až 200 mm CMC 0,0019 mm J 62.03.G01 Srednicowki trojpunktowe Wzorcowanie – dlugosc Pomiar za pomoca pierscieni nastawczych od 6 mm do 200 mm CMC 0,0019 mm Tridotekove dutinomery Kalibrace – delka Mereni pomoci nastavnych krouzku 6 mm az 200 mm CMC 0,0019 mm J 62.03.G01","search_en":"Three-contact internal gauges Calibration – length Measurement by setting rings 6 mm to 200 mm CMC 0,0019 mm J 62.03.G01","search_zh":"三点式内径表 校准 – 长度 用校对环规测量 6 mm 至 200 mm CMC 0,0019 mm J 62.03.G01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b18329d0abab35a342c04d2f","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Suwmiarki","test_object_en":"Slide gauges","test_object_zh":"游标卡尺","test_object_cs":"Posuvná měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 2 000 mm","cmc":"0,012 mm"}],"parameters_en":[{"name":"","range":"0 mm to 2 000 mm","cmc":"0,012 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 2 000 mm","cmc":"0,012 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 2 000 mm","cmc":"0,012 mm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 2 000 mm CMC 0,012 mm\nPomiar za pomocą płytek wzorcowych","reference":"J 62.03.G02","norm_bases":["J 62.03.G02"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Suwmiarki Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 2 000 mm CMC 0,012 mm Posuvná měřidla Kalibrace – délka Měření pomocí koncových měrek 0 mm až 2 000 mm CMC 0,012 mm J 62.03.G02 Suwmiarki Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 2 000 mm CMC 0,012 mm Posuvna meridla Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 2 000 mm CMC 0,012 mm J 62.03.G02","search_en":"Slide gauges Calibration – length Measurement using parallel gauge blocks 0 mm to 2 000 mm CMC 0,012 mm J 62.03.G02","search_zh":"游标卡尺 校准 – 长度 用量块测量 0 mm 至 2 000 mm CMC 0,012 mm J 62.03.G02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"24cf7c9837d6fd8746f69b7d","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Suwmiarki","test_object_en":"Slide gauges","test_object_zh":"游标卡尺","test_object_cs":"Posuvná měřidla","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 2 000 mm","cmc":"0,012 mm"}],"parameters_en":[{"name":"","range":"0 mm to 2 000 mm","cmc":"0,012 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 2 000 mm","cmc":"0,012 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 2 000 mm","cmc":"0,012 mm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 2 000 mm CMC 0,012 mm\nPomiar za pomocą płytek wzorcowych","reference":"J 62.03.G02","norm_bases":["J 62.03.G02"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Suwmiarki Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 0 mm do 2 000 mm CMC 0,012 mm Posuvná měřidla Kalibrace – délka Měření pomocí koncových měrek 0 mm až 2 000 mm CMC 0,012 mm J 62.03.G02 Suwmiarki Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 0 mm do 2 000 mm CMC 0,012 mm Posuvna meridla Kalibrace – delka Mereni pomoci koncovych merek 0 mm az 2 000 mm CMC 0,012 mm J 62.03.G02","search_en":"Slide gauges Calibration – length Measurement using parallel gauge blocks 0 mm to 2 000 mm CMC 0,012 mm J 62.03.G02","search_zh":"游标卡尺 校准 – 长度 用量块测量 0 mm 至 2 000 mm CMC 0,012 mm J 62.03.G02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"675c0e54dcffa26ace9cf00f","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Czujniki pomiarowe / zegarowe, cyfrowe, dźwigniowe","test_object_en":"Indicators / dial, digital, lever","test_object_zh":"指示表 / 指针式、数字式、杠杆式","test_object_cs":"Úchylkoměry / číselné, digitální, páčkové","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"działka 0,001 mm","range":"od 0 mm do 5 mm","cmc":"0,00033 mm"},{"name":"działka 0,001 mm","range":"od 5 mm do 13 mm","cmc":"0,00034 mm"},{"name":"działka 0,01 mm","range":"od 0 mm do 50 mm","cmc":"0,0012 mm"},{"name":"działka 0,01 mm","range":"od 50 mm do 100 mm","cmc":"0,0013 mm"}],"parameters_en":[{"name":"division 0.001 mm","range":"0 mm to 5 mm","cmc":"0,00033 mm"},{"name":"division 0.001 mm","range":"5 mm to 13 mm","cmc":"0,00034 mm"},{"name":"division 0.01 mm","range":"0 mm to 50 mm","cmc":"0,0012 mm"},{"name":"division 0.01 mm","range":"50 mm to 100 mm","cmc":"0,0013 mm"}],"parameters_zh":[{"name":"分度值 0,001 mm","range":"0 mm 至 5 mm","cmc":"0,00033 mm"},{"name":"分度值 0,001 mm","range":"5 mm 至 13 mm","cmc":"0,00034 mm"},{"name":"分度值 0,01 mm","range":"0 mm 至 50 mm","cmc":"0,0012 mm"},{"name":"分度值 0,01 mm","range":"50 mm 至 100 mm","cmc":"0,0013 mm"}],"parameters_cs":[{"name":"dílek 0,001 mm","range":"0 mm až 5 mm","cmc":"0,00033 mm"},{"name":"dílek 0,001 mm","range":"5 mm až 13 mm","cmc":"0,00034 mm"},{"name":"dílek 0,01 mm","range":"0 mm až 50 mm","cmc":"0,0012 mm"},{"name":"dílek 0,01 mm","range":"50 mm až 100 mm","cmc":"0,0013 mm"}],"technique":"Pomiar za pomocą przyrządu do wzorcowania czujników pomiarowych","technique_en":"Measurement on a dial indicator calibration instrument","technique_zh":"用指示表校准仪测量","technique_cs":"Měření pomocí přístroje pro kalibrace úchylkoměrů","techniques":["Pomiar za pomocą przyrządu do wzorcowania czujników pomiarowych"],"techniques_en":["Measurement on a dial indicator calibration instrument"],"techniques_zh":["用指示表校准仪测量"],"techniques_cs":["Měření pomocí přístroje pro kalibrace úchylkoměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndziałka 0,001 mm od 0 mm do 5 mm CMC 0,00033 mm\ndziałka 0,001 mm od 5 mm do 13 mm CMC 0,00034 mm\ndziałka 0,01 mm od 0 mm do 50 mm CMC 0,0012 mm\ndziałka 0,01 mm od 50 mm do 100 mm CMC 0,0013 mm\nPomiar za pomocą przyrządu do wzorcowania czujników pomiarowych","reference":"J 62.03.G03","norm_bases":["J 62.03.G03"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki pomiarowe / zegarowe, cyfrowe, dźwigniowe Wzorcowanie – długość Pomiar za pomocą przyrządu do wzorcowania czujników pomiarowych działka 0,001 mm od 0 mm do 5 mm CMC 0,00033 mm działka 0,001 mm od 5 mm do 13 mm CMC 0,00034 mm działka 0,01 mm od 0 mm do 50 mm CMC 0,0012 mm działka 0,01 mm od 50 mm do 100 mm CMC 0,0013 mm Úchylkoměry / číselné, digitální, páčkové Kalibrace – délka Měření pomocí přístroje pro kalibrace úchylkoměrů dílek 0,001 mm 0 mm až 5 mm CMC 0,00033 mm dílek 0,001 mm 5 mm až 13 mm CMC 0,00034 mm dílek 0,01 mm 0 mm až 50 mm CMC 0,0012 mm dílek 0,01 mm 50 mm až 100 mm CMC 0,0013 mm J 62.03.G03 Czujniki pomiarowe / zegarowe, cyfrowe, dzwigniowe Wzorcowanie – dlugosc Pomiar za pomoca przyrzadu do wzorcowania czujnikow pomiarowych dzialka 0,001 mm od 0 mm do 5 mm CMC 0,00033 mm dzialka 0,001 mm od 5 mm do 13 mm CMC 0,00034 mm dzialka 0,01 mm od 0 mm do 50 mm CMC 0,0012 mm dzialka 0,01 mm od 50 mm do 100 mm CMC 0,0013 mm Uchylkomery / ciselne, digitalni, packove Kalibrace – delka Mereni pomoci pristroje pro kalibrace uchylkomeru dilek 0,001 mm 0 mm az 5 mm CMC 0,00033 mm dilek 0,001 mm 5 mm az 13 mm CMC 0,00034 mm dilek 0,01 mm 0 mm az 50 mm CMC 0,0012 mm dilek 0,01 mm 50 mm az 100 mm CMC 0,0013 mm J 62.03.G03","search_en":"Indicators / dial, digital, lever Calibration – length Measurement on a dial indicator calibration instrument division 0.001 mm 0 mm to 5 mm CMC 0,00033 mm division 0.001 mm 5 mm to 13 mm CMC 0,00034 mm division 0.01 mm 0 mm to 50 mm CMC 0,0012 mm division 0.01 mm 50 mm to 100 mm CMC 0,0013 mm J 62.03.G03","search_zh":"指示表 / 指针式、数字式、杠杆式 校准 – 长度 用指示表校准仪测量 分度值 0,001 mm 0 mm 至 5 mm CMC 0,00033 mm 分度值 0,001 mm 5 mm 至 13 mm CMC 0,00034 mm 分度值 0,01 mm 0 mm 至 50 mm CMC 0,0012 mm 分度值 0,01 mm 50 mm 至 100 mm CMC 0,0013 mm J 62.03.G03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3add568b0ab072b1f8886f46","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Czujniki pomiarowe / zegarowe, cyfrowe, dźwigniowe","test_object_en":"Indicators / dial, digital, lever","test_object_zh":"指示表 / 指针式、数字式、杠杆式","test_object_cs":"Úchylkoměry / číselné, digitální, páčkové","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"działka 0,001 mm","range":"od 0 mm do 5 mm","cmc":"0,00033 mm"},{"name":"działka 0,001 mm","range":"od 5 mm do 13 mm","cmc":"0,00034 mm"},{"name":"działka 0,01 mm","range":"od 0 mm do 50 mm","cmc":"0,0012 mm"},{"name":"działka 0,01 mm","range":"od 50 mm do 100 mm","cmc":"0,0013 mm"}],"parameters_en":[{"name":"division 0.001 mm","range":"0 mm to 5 mm","cmc":"0,00033 mm"},{"name":"division 0.001 mm","range":"5 mm to 13 mm","cmc":"0,00034 mm"},{"name":"division 0.01 mm","range":"0 mm to 50 mm","cmc":"0,0012 mm"},{"name":"division 0.01 mm","range":"50 mm to 100 mm","cmc":"0,0013 mm"}],"parameters_zh":[{"name":"分度值 0,001 mm","range":"0 mm 至 5 mm","cmc":"0,00033 mm"},{"name":"分度值 0,001 mm","range":"5 mm 至 13 mm","cmc":"0,00034 mm"},{"name":"分度值 0,01 mm","range":"0 mm 至 50 mm","cmc":"0,0012 mm"},{"name":"分度值 0,01 mm","range":"50 mm 至 100 mm","cmc":"0,0013 mm"}],"parameters_cs":[{"name":"dílek 0,001 mm","range":"0 mm až 5 mm","cmc":"0,00033 mm"},{"name":"dílek 0,001 mm","range":"5 mm až 13 mm","cmc":"0,00034 mm"},{"name":"dílek 0,01 mm","range":"0 mm až 50 mm","cmc":"0,0012 mm"},{"name":"dílek 0,01 mm","range":"50 mm až 100 mm","cmc":"0,0013 mm"}],"technique":"Pomiar za pomocą przyrządu do wzorcowania czujników pomiarowych","technique_en":"Measurement on a dial indicator calibration instrument","technique_zh":"用指示表校准仪测量","technique_cs":"Měření pomocí přístroje pro kalibrace úchylkoměrů","techniques":["Pomiar za pomocą przyrządu do wzorcowania czujników pomiarowych"],"techniques_en":["Measurement on a dial indicator calibration instrument"],"techniques_zh":["用指示表校准仪测量"],"techniques_cs":["Měření pomocí přístroje pro kalibrace úchylkoměrů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nZakres:\ndziałka 0,001 mm od 0 mm do 5 mm CMC 0,00033 mm\ndziałka 0,001 mm od 5 mm do 13 mm CMC 0,00034 mm\ndziałka 0,01 mm od 0 mm do 50 mm CMC 0,0012 mm\ndziałka 0,01 mm od 50 mm do 100 mm CMC 0,0013 mm\nPomiar za pomocą przyrządu do wzorcowania czujników pomiarowych","reference":"J 62.03.G03","norm_bases":["J 62.03.G03"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki pomiarowe / zegarowe, cyfrowe, dźwigniowe Wzorcowanie – długość Pomiar za pomocą przyrządu do wzorcowania czujników pomiarowych działka 0,001 mm od 0 mm do 5 mm CMC 0,00033 mm działka 0,001 mm od 5 mm do 13 mm CMC 0,00034 mm działka 0,01 mm od 0 mm do 50 mm CMC 0,0012 mm działka 0,01 mm od 50 mm do 100 mm CMC 0,0013 mm Úchylkoměry / číselné, digitální, páčkové Kalibrace – délka Měření pomocí přístroje pro kalibrace úchylkoměrů dílek 0,001 mm 0 mm až 5 mm CMC 0,00033 mm dílek 0,001 mm 5 mm až 13 mm CMC 0,00034 mm dílek 0,01 mm 0 mm až 50 mm CMC 0,0012 mm dílek 0,01 mm 50 mm až 100 mm CMC 0,0013 mm J 62.03.G03 Czujniki pomiarowe / zegarowe, cyfrowe, dzwigniowe Wzorcowanie – dlugosc Pomiar za pomoca przyrzadu do wzorcowania czujnikow pomiarowych dzialka 0,001 mm od 0 mm do 5 mm CMC 0,00033 mm dzialka 0,001 mm od 5 mm do 13 mm CMC 0,00034 mm dzialka 0,01 mm od 0 mm do 50 mm CMC 0,0012 mm dzialka 0,01 mm od 50 mm do 100 mm CMC 0,0013 mm Uchylkomery / ciselne, digitalni, packove Kalibrace – delka Mereni pomoci pristroje pro kalibrace uchylkomeru dilek 0,001 mm 0 mm az 5 mm CMC 0,00033 mm dilek 0,001 mm 5 mm az 13 mm CMC 0,00034 mm dilek 0,01 mm 0 mm az 50 mm CMC 0,0012 mm dilek 0,01 mm 50 mm az 100 mm CMC 0,0013 mm J 62.03.G03","search_en":"Indicators / dial, digital, lever Calibration – length Measurement on a dial indicator calibration instrument division 0.001 mm 0 mm to 5 mm CMC 0,00033 mm division 0.001 mm 5 mm to 13 mm CMC 0,00034 mm division 0.01 mm 0 mm to 50 mm CMC 0,0012 mm division 0.01 mm 50 mm to 100 mm CMC 0,0013 mm J 62.03.G03","search_zh":"指示表 / 指针式、数字式、杠杆式 校准 – 长度 用指示表校准仪测量 分度值 0,001 mm 0 mm 至 5 mm CMC 0,00033 mm 分度值 0,001 mm 5 mm 至 13 mm CMC 0,00034 mm 分度值 0,01 mm 0 mm 至 50 mm CMC 0,0012 mm 分度值 0,01 mm 50 mm 至 100 mm CMC 0,0013 mm J 62.03.G03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"62781b53242b12f1b0d63200","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Wzorniki spoin / podziałki liniowe","test_object_en":"Weld gauges / linear scales","test_object_zh":"焊缝量规 / 长度刻度","test_object_cs":"Svarové měrky / délkové stupnice","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 50 mm","cmc":"0,026 mm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"0,026 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"0,026 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 50 mm","cmc":"0,026 mm"}],"technique":"Pomiar za pomocą suwmiarki","technique_en":"Measuring with a slide gauge","technique_zh":"用游标卡尺测量","technique_cs":"Měření pomocí posuvného měřidla","techniques":["Pomiar za pomocą suwmiarki"],"techniques_en":["Measuring with a slide gauge"],"techniques_zh":["用游标卡尺测量"],"techniques_cs":["Měření pomocí posuvného měřidla"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 50 mm CMC 0,026 mm\nPomiar za pomocą suwmiarki","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki liniowe Wzorcowanie – długość Pomiar za pomocą suwmiarki od 0 mm do 50 mm CMC 0,026 mm Svarové měrky / délkové stupnice Kalibrace – délka Měření pomocí posuvného měřidla 0 mm až 50 mm CMC 0,026 mm J 62.03.G04 Wzorniki spoin / podzialki liniowe Wzorcowanie – dlugosc Pomiar za pomoca suwmiarki od 0 mm do 50 mm CMC 0,026 mm Svarove merky / delkove stupnice Kalibrace – delka Mereni pomoci posuvneho meridla 0 mm az 50 mm CMC 0,026 mm J 62.03.G04","search_en":"Weld gauges / linear scales Calibration – length Measuring with a slide gauge 0 mm to 50 mm CMC 0,026 mm J 62.03.G04","search_zh":"焊缝量规 / 长度刻度 校准 – 长度 用游标卡尺测量 0 mm 至 50 mm CMC 0,026 mm J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44cc3a634663b46d01eead20","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Wzorniki spoin / podziałki liniowe","test_object_en":"Weld gauges / linear scales","test_object_zh":"焊缝量规 / 长度刻度","test_object_cs":"Svarové měrky / délkové stupnice","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 0 mm do 50 mm","cmc":"0,026 mm"}],"parameters_en":[{"name":"","range":"0 mm to 50 mm","cmc":"0,026 mm"}],"parameters_zh":[{"name":"","range":"0 mm 至 50 mm","cmc":"0,026 mm"}],"parameters_cs":[{"name":"","range":"0 mm až 50 mm","cmc":"0,026 mm"}],"technique":"Pomiar za pomocą suwmiarki","technique_en":"Measuring with a slide gauge","technique_zh":"用游标卡尺测量","technique_cs":"Měření pomocí posuvného měřidla","techniques":["Pomiar za pomocą suwmiarki"],"techniques_en":["Measuring with a slide gauge"],"techniques_zh":["用游标卡尺测量"],"techniques_cs":["Měření pomocí posuvného měřidla"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 0 mm do 50 mm CMC 0,026 mm\nPomiar za pomocą suwmiarki","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki liniowe Wzorcowanie – długość Pomiar za pomocą suwmiarki od 0 mm do 50 mm CMC 0,026 mm Svarové měrky / délkové stupnice Kalibrace – délka Měření pomocí posuvného měřidla 0 mm až 50 mm CMC 0,026 mm J 62.03.G04 Wzorniki spoin / podzialki liniowe Wzorcowanie – dlugosc Pomiar za pomoca suwmiarki od 0 mm do 50 mm CMC 0,026 mm Svarove merky / delkove stupnice Kalibrace – delka Mereni pomoci posuvneho meridla 0 mm az 50 mm CMC 0,026 mm J 62.03.G04","search_en":"Weld gauges / linear scales Calibration – length Measuring with a slide gauge 0 mm to 50 mm CMC 0,026 mm J 62.03.G04","search_zh":"焊缝量规 / 长度刻度 校准 – 长度 用游标卡尺测量 0 mm 至 50 mm CMC 0,026 mm J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73f90c181e2f098e1d2a2370","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Wzorniki spoin / podziałki liniowe","test_object_en":"Weld gauges / linear scales","test_object_zh":"焊缝量规 / 长度刻度","test_object_cs":"Svarové měrky / délkové stupnice","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 50 mm do 60 mm","cmc":"0,23 mm"}],"parameters_en":[{"name":"","range":"50 mm to 60 mm","cmc":"0,23 mm"}],"parameters_zh":[{"name":"","range":"50 mm 至 60 mm","cmc":"0,23 mm"}],"parameters_cs":[{"name":"","range":"50 mm až 60 mm","cmc":"0,23 mm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 50 mm do 60 mm CMC 0,23 mm\nPomiar za pomocą płytek wzorcowych","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki liniowe Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 50 mm do 60 mm CMC 0,23 mm Svarové měrky / délkové stupnice Kalibrace – délka Měření pomocí koncových měrek 50 mm až 60 mm CMC 0,23 mm J 62.03.G04 Wzorniki spoin / podzialki liniowe Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 50 mm do 60 mm CMC 0,23 mm Svarove merky / delkove stupnice Kalibrace – delka Mereni pomoci koncovych merek 50 mm az 60 mm CMC 0,23 mm J 62.03.G04","search_en":"Weld gauges / linear scales Calibration – length Measurement using parallel gauge blocks 50 mm to 60 mm CMC 0,23 mm J 62.03.G04","search_zh":"焊缝量规 / 长度刻度 校准 – 长度 用量块测量 50 mm 至 60 mm CMC 0,23 mm J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d104971f8f1ede47e7adb2f6","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Wzorniki spoin / podziałki liniowe","test_object_en":"Weld gauges / linear scales","test_object_zh":"焊缝量规 / 长度刻度","test_object_cs":"Svarové měrky / délkové stupnice","methodology":"Wzorcowanie – długość","methodology_en":"Calibration – length","methodology_zh":"校准 – 长度","methodology_cs":"Kalibrace – délka","parameters":[{"name":"","range":"od 50 mm do 60 mm","cmc":"0,23 mm"}],"parameters_en":[{"name":"","range":"50 mm to 60 mm","cmc":"0,23 mm"}],"parameters_zh":[{"name":"","range":"50 mm 至 60 mm","cmc":"0,23 mm"}],"parameters_cs":[{"name":"","range":"50 mm až 60 mm","cmc":"0,23 mm"}],"technique":"Pomiar za pomocą płytek wzorcowych","technique_en":"Measurement using parallel gauge blocks","technique_zh":"用量块测量","technique_cs":"Měření pomocí koncových měrek","techniques":["Pomiar za pomocą płytek wzorcowych"],"techniques_en":["Measurement using parallel gauge blocks"],"techniques_zh":["用量块测量"],"techniques_cs":["Měření pomocí koncových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – długość\nod 50 mm do 60 mm CMC 0,23 mm\nPomiar za pomocą płytek wzorcowych","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: długość","regulatory_area_en":"CMC for the field of measured quantity: Length","regulatory_area_zh":"被测量领域的CMC：长度","regulatory_area_cs":"CMC pro obor měřené veličiny: Délka","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki liniowe Wzorcowanie – długość Pomiar za pomocą płytek wzorcowych od 50 mm do 60 mm CMC 0,23 mm Svarové měrky / délkové stupnice Kalibrace – délka Měření pomocí koncových měrek 50 mm až 60 mm CMC 0,23 mm J 62.03.G04 Wzorniki spoin / podzialki liniowe Wzorcowanie – dlugosc Pomiar za pomoca plytek wzorcowych od 50 mm do 60 mm CMC 0,23 mm Svarove merky / delkove stupnice Kalibrace – delka Mereni pomoci koncovych merek 50 mm az 60 mm CMC 0,23 mm J 62.03.G04","search_en":"Weld gauges / linear scales Calibration – length Measurement using parallel gauge blocks 50 mm to 60 mm CMC 0,23 mm J 62.03.G04","search_zh":"焊缝量规 / 长度刻度 校准 – 长度 用量块测量 50 mm 至 60 mm CMC 0,23 mm J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af7760e5957d9f218ac9e52b","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Wzorniki spoin / podziałki kątowe","test_object_en":"Weld gauges / angular scales","test_object_zh":"焊缝量规 / 角度刻度","test_object_cs":"Svarové měrky / úhlové stupnice","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0° do 90°","cmc":"0,1°"}],"parameters_en":[{"name":"","range":"0° to 90°","cmc":"0,1°"}],"parameters_zh":[{"name":"","range":"0° 至 90°","cmc":"0,1°"}],"parameters_cs":[{"name":"","range":"0° až 90°","cmc":"0,1°"}],"technique":"Pomiar za pomocą kątomierza","technique_en":"Measuring with an angle gauge","technique_zh":"用量角器测量","technique_cs":"Měření pomocí úhloměru","techniques":["Pomiar za pomocą kątomierza"],"techniques_en":["Measuring with an angle gauge"],"techniques_zh":["用量角器测量"],"techniques_cs":["Měření pomocí úhloměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0° do 90° CMC 0,1°\nPomiar za pomocą kątomierza","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki kątowe Wzorcowanie – kąt płaski Pomiar za pomocą kątomierza od 0° do 90° CMC 0,1° Svarové měrky / úhlové stupnice Kalibrace – rovinný úhel Měření pomocí úhloměru 0° až 90° CMC 0,1° J 62.03.G04 Wzorniki spoin / podzialki katowe Wzorcowanie – kat plaski Pomiar za pomoca katomierza od 0° do 90° CMC 0,1° Svarove merky / uhlove stupnice Kalibrace – rovinny uhel Mereni pomoci uhlomeru 0° az 90° CMC 0,1° J 62.03.G04","search_en":"Weld gauges / angular scales Calibration – plane angle Measuring with an angle gauge 0° to 90° CMC 0,1° J 62.03.G04","search_zh":"焊缝量规 / 角度刻度 校准 – 平面角 用量角器测量 0° 至 90° CMC 0,1° J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9169907dec474223862efe96","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Wzorniki spoin / podziałki kątowe","test_object_en":"Weld gauges / angular scales","test_object_zh":"焊缝量规 / 角度刻度","test_object_cs":"Svarové měrky / úhlové stupnice","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 0° do 90°","cmc":"0,1°"}],"parameters_en":[{"name":"","range":"0° to 90°","cmc":"0,1°"}],"parameters_zh":[{"name":"","range":"0° 至 90°","cmc":"0,1°"}],"parameters_cs":[{"name":"","range":"0° až 90°","cmc":"0,1°"}],"technique":"Pomiar za pomocą kątomierza","technique_en":"Measuring with an angle gauge","technique_zh":"用量角器测量","technique_cs":"Měření pomocí úhloměru","techniques":["Pomiar za pomocą kątomierza"],"techniques_en":["Measuring with an angle gauge"],"techniques_zh":["用量角器测量"],"techniques_cs":["Měření pomocí úhloměru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 0° do 90° CMC 0,1°\nPomiar za pomocą kątomierza","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki kątowe Wzorcowanie – kąt płaski Pomiar za pomocą kątomierza od 0° do 90° CMC 0,1° Svarové měrky / úhlové stupnice Kalibrace – rovinný úhel Měření pomocí úhloměru 0° až 90° CMC 0,1° J 62.03.G04 Wzorniki spoin / podzialki katowe Wzorcowanie – kat plaski Pomiar za pomoca katomierza od 0° do 90° CMC 0,1° Svarove merky / uhlove stupnice Kalibrace – rovinny uhel Mereni pomoci uhlomeru 0° az 90° CMC 0,1° J 62.03.G04","search_en":"Weld gauges / angular scales Calibration – plane angle Measuring with an angle gauge 0° to 90° CMC 0,1° J 62.03.G04","search_zh":"焊缝量规 / 角度刻度 校准 – 平面角 用量角器测量 0° 至 90° CMC 0,1° J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ec2f9a3e885f009c927583b","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Wzorniki spoin / podziałki kątowe","test_object_en":"Weld gauges / angular scales","test_object_zh":"焊缝量规 / 角度刻度","test_object_cs":"Svarové měrky / úhlové stupnice","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 90° do 150°","cmc":"1,2°"}],"parameters_en":[{"name":"","range":"90° to 150°","cmc":"1,2°"}],"parameters_zh":[{"name":"","range":"90° 至 150°","cmc":"1,2°"}],"parameters_cs":[{"name":"","range":"90° až 150°","cmc":"1,2°"}],"technique":"Pomiar za pomocą płytek kątowych","technique_en":"Measurement using angle gauges","technique_zh":"用角度量块测量","technique_cs":"Měření pomocí úhlových měrek","techniques":["Pomiar za pomocą płytek kątowych"],"techniques_en":["Measurement using angle gauges"],"techniques_zh":["用角度量块测量"],"techniques_cs":["Měření pomocí úhlových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 90° do 150° CMC 1,2°\nPomiar za pomocą płytek kątowych","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki kątowe Wzorcowanie – kąt płaski Pomiar za pomocą płytek kątowych od 90° do 150° CMC 1,2° Svarové měrky / úhlové stupnice Kalibrace – rovinný úhel Měření pomocí úhlových měrek 90° až 150° CMC 1,2° J 62.03.G04 Wzorniki spoin / podzialki katowe Wzorcowanie – kat plaski Pomiar za pomoca plytek katowych od 90° do 150° CMC 1,2° Svarove merky / uhlove stupnice Kalibrace – rovinny uhel Mereni pomoci uhlovych merek 90° az 150° CMC 1,2° J 62.03.G04","search_en":"Weld gauges / angular scales Calibration – plane angle Measurement using angle gauges 90° to 150° CMC 1,2° J 62.03.G04","search_zh":"焊缝量规 / 角度刻度 校准 – 平面角 用角度量块测量 90° 至 150° CMC 1,2° J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a930df3a5e2ca32f081a8367","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Wzorniki spoin / podziałki kątowe","test_object_en":"Weld gauges / angular scales","test_object_zh":"焊缝量规 / 角度刻度","test_object_cs":"Svarové měrky / úhlové stupnice","methodology":"Wzorcowanie – kąt płaski","methodology_en":"Calibration – plane angle","methodology_zh":"校准 – 平面角","methodology_cs":"Kalibrace – rovinný úhel","parameters":[{"name":"","range":"od 90° do 150°","cmc":"1,2°"}],"parameters_en":[{"name":"","range":"90° to 150°","cmc":"1,2°"}],"parameters_zh":[{"name":"","range":"90° 至 150°","cmc":"1,2°"}],"parameters_cs":[{"name":"","range":"90° až 150°","cmc":"1,2°"}],"technique":"Pomiar za pomocą płytek kątowych","technique_en":"Measurement using angle gauges","technique_zh":"用角度量块测量","technique_cs":"Měření pomocí úhlových měrek","techniques":["Pomiar za pomocą płytek kątowych"],"techniques_en":["Measurement using angle gauges"],"techniques_zh":["用角度量块测量"],"techniques_cs":["Měření pomocí úhlových měrek"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – kąt płaski\nod 90° do 150° CMC 1,2°\nPomiar za pomocą płytek kątowych","reference":"J 62.03.G04","norm_bases":["J 62.03.G04"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: kąt płaski","regulatory_area_en":"CMC for the field of measured quantity: Plane angle","regulatory_area_zh":"被测量领域的CMC：平面角","regulatory_area_cs":"CMC pro obor měřené veličiny: Rovinný úhel","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wzorniki spoin / podziałki kątowe Wzorcowanie – kąt płaski Pomiar za pomocą płytek kątowych od 90° do 150° CMC 1,2° Svarové měrky / úhlové stupnice Kalibrace – rovinný úhel Měření pomocí úhlových měrek 90° až 150° CMC 1,2° J 62.03.G04 Wzorniki spoin / podzialki katowe Wzorcowanie – kat plaski Pomiar za pomoca plytek katowych od 90° do 150° CMC 1,2° Svarove merky / uhlove stupnice Kalibrace – rovinny uhel Mereni pomoci uhlovych merek 90° az 150° CMC 1,2° J 62.03.G04","search_en":"Weld gauges / angular scales Calibration – plane angle Measurement using angle gauges 90° to 150° CMC 1,2° J 62.03.G04","search_zh":"焊缝量规 / 角度刻度 校准 – 平面角 用角度量块测量 90° 至 150° CMC 1,2° J 62.03.G04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"731c7e389fd5a397826d5a82","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne, elektroniczne","test_object_en":"Scales with non-automatic function, electronic","test_object_zh":"非自动衡器，电子式","test_object_cs":"Váhy s neautomatickou činností, elektronické","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"W zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować następujące wartości","range":"od 1 mg do 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"parameters_en":[{"name":"According to the weights used for calibration, Uᵢ can have the following values","range":"1 mg to 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"parameters_zh":[{"name":"根据校准所用砝码，Uᵢ 可取下列值","range":"1 mg 至 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"parameters_cs":[{"name":"Podle závaží použitých při kalibraci může Uᵢ nabývat těchto hodnot","range":"1 mg až 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2","technique_en":"Load with standard weights (according to OIML R 111-1:2004) class E2","technique_zh":"用E2级标准砝码加载（依据 OIML R 111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R 111-1:2004) třídy E2","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2"],"techniques_en":["Load with standard weights (according to OIML R 111-1:2004) class E2"],"techniques_zh":["用E2级标准砝码加载（依据 OIML R 111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R 111-1:2004) třídy E2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nW zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować następujące wartości od 1 mg do 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg\nObciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2","reference":"J 62.06.W01","norm_bases":["J 62.06.W01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne, elektroniczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 W zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować następujące wartości od 1 mg do 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg Váhy s neautomatickou činností, elektronické Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R 111-1:2004) třídy E2 Podle závaží použitých při kalibraci může Uᵢ nabývat těchto hodnot 1 mg až 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01 Wagi nieautomatyczne, elektroniczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 W zaleznosci od odwaznikow uzytych przy wzorcowaniu Uᵢ moze przyjmowac nastepujace wartosci od 1 mg do 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg Vahy s neautomatickou cinnosti, elektronicke Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R 111-1:2004) tridy E2 Podle zavazi pouzitych pri kalibraci muze Uᵢ nabyvat techto hodnot 1 mg az 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01","search_en":"Scales with non-automatic function, electronic Calibration – mass Load with standard weights (according to OIML R 111-1:2004) class E2 According to the weights used for calibration, Uᵢ can have the following values 1 mg to 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01","search_zh":"非自动衡器，电子式 校准 – 质量 用E2级标准砝码加载（依据 OIML R 111-1:2004） 根据校准所用砝码，Uᵢ 可取下列值 1 mg 至 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"15cd08c14614ccd2b1cfecbb","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Wagi nieautomatyczne, elektroniczne","test_object_en":"Scales with non-automatic function, electronic","test_object_zh":"非自动衡器，电子式","test_object_cs":"Váhy s neautomatickou činností, elektronické","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"W zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować następujące wartości","range":"od 1 mg do 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"parameters_en":[{"name":"According to the weights used for calibration, Uᵢ can have the following values","range":"1 mg to 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"parameters_zh":[{"name":"根据校准所用砝码，Uᵢ 可取下列值","range":"1 mg 至 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"parameters_cs":[{"name":"Podle závaží použitých při kalibraci může Uᵢ nabývat těchto hodnot","range":"1 mg až 19 kg","cmc":"U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg"}],"technique":"Obciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2","technique_en":"Load with standard weights (according to OIML R 111-1:2004) class E2","technique_zh":"用E2级标准砝码加载（依据 OIML R 111-1:2004）","technique_cs":"Zatížení etalonovým závažím (dle OIML R 111-1:2004) třídy E2","techniques":["Obciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2"],"techniques_en":["Load with standard weights (according to OIML R 111-1:2004) class E2"],"techniques_zh":["用E2级标准砝码加载（依据 OIML R 111-1:2004）"],"techniques_cs":["Zatížení etalonovým závažím (dle OIML R 111-1:2004) třídy E2"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nW zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować następujące wartości od 1 mg do 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg\nObciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2","reference":"J 62.06.W01","norm_bases":["J 62.06.W01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wagi nieautomatyczne, elektroniczne Wzorcowanie – masa Obciążenie odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 W zależności od odważników użytych przy wzorcowaniu Uᵢ może przyjmować następujące wartości od 1 mg do 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg Váhy s neautomatickou činností, elektronické Kalibrace – hmotnost Zatížení etalonovým závažím (dle OIML R 111-1:2004) třídy E2 Podle závaží použitých při kalibraci může Uᵢ nabývat těchto hodnot 1 mg až 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01 Wagi nieautomatyczne, elektroniczne Wzorcowanie – masa Obciazenie odwaznikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 W zaleznosci od odwaznikow uzytych przy wzorcowaniu Uᵢ moze przyjmowac nastepujace wartosci od 1 mg do 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg Vahy s neautomatickou cinnosti, elektronicke Kalibrace – hmotnost Zatizeni etalonovym zavazim (dle OIML R 111-1:2004) tridy E2 Podle zavazi pouzitych pri kalibraci muze Uᵢ nabyvat techto hodnot 1 mg az 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01","search_en":"Scales with non-automatic function, electronic Calibration – mass Load with standard weights (according to OIML R 111-1:2004) class E2 According to the weights used for calibration, Uᵢ can have the following values 1 mg to 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01","search_zh":"非自动衡器，电子式 校准 – 质量 用E2级标准砝码加载（依据 OIML R 111-1:2004） 根据校准所用砝码，Uᵢ 可取下列值 1 mg 至 19 kg CMC U₁ (1 mg) = 2,7·10⁻³ mg; U₂ (2 mg) = 2,7·10⁻³ mg; U₃ (5 mg) = 2,7·10⁻³ mg; U₄ (10 mg) = 3,6·10⁻³ mg; U₅ (20 mg) = 4,5·10⁻³ mg; U₆ (50 mg) = 5,3·10⁻³ mg; U₇ (100 mg) = 7,1·10⁻³ mg; U₈ (200 mg) = 8,9·10⁻³ mg; U₉ (500 mg) = 1,2·10⁻² mg; U₁₀ (1 g) = 1,4·10⁻² mg; U₁₁ (2 g) = 1,8·10⁻² mg; U₁₂ (5 g) = 2,3·10⁻² mg; U₁₃ (10 g) = 2,7·10⁻² mg; U₁₄ (20 g) = 3,6·10⁻² mg; U₁₅ (50 g) = 4,5·10⁻² mg; U₁₆ (100 g) = 7,1·10⁻² mg; U₁₇ (200 g) = 1,4·10⁻¹ mg; U₁₈ (500 g) = 3,6·10⁻¹ mg; U₁₉ (1 kg) = 7,1·10⁻¹ mg; U₂₀ (2 kg) = 1,3·10⁰ mg; U₂₁ (5 kg) = 3,5·10⁰ mg; U₂₂ (10 kg) = 7,1·10⁰ mg J 62.06.W01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be4e2c3db78a653dcf92ab94","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Odważniki klasy F1, F2, M","test_object_en":"F1, F2, M class weights","test_object_zh":"F1、F2、M 级砝码","test_object_cs":"Závaží třídy F1, F2, M","methodology":"Wzorcowanie – masa","methodology_en":"Calibration – mass","methodology_zh":"校准 – 质量","methodology_cs":"Kalibrace – hmotnost","parameters":[{"name":"","range":"od 1 mg do 5 mg","cmc":"4,6·10⁻³ mg"},{"name":"","range":"10 mg","cmc":"4,9·10⁻³ mg"},{"name":"","range":"20 mg","cmc":"5,3·10⁻³ mg"},{"name":"","range":"50 mg","cmc":"5,8·10⁻³ mg"},{"name":"","range":"100 mg","cmc":"6,8·10⁻³ mg"},{"name":"","range":"200 mg","cmc":"8,0·10⁻³ mg"},{"name":"","range":"500 mg","cmc":"1,0·10⁻² mg"},{"name":"","range":"1 g","cmc":"1,1·10⁻² mg"},{"name":"","range":"2 g","cmc":"1,4·10⁻² mg"},{"name":"","range":"5 g","cmc":"1,8·10⁻² mg"},{"name":"","range":"10 g","cmc":"2,1·10⁻² mg"},{"name":"","range":"20 g","cmc":"2,7·10⁻² mg"},{"name":"","range":"50 g","cmc":"3,4·10⁻² mg"},{"name":"","range":"100 g","cmc":"5,5·10⁻² mg"},{"name":"","range":"200 g","cmc":"1,1·10⁻¹ mg"},{"name":"","range":"500 g","cmc":"8,2·10⁰ mg"},{"name":"","range":"1 kg","cmc":"8,2·10⁰ mg"},{"name":"","range":"2 kg","cmc":"8,3·10⁰ mg"},{"name":"","range":"5 kg","cmc":"8,6·10⁰ mg"},{"name":"","range":"10 kg","cmc":"8,2·10¹ mg"}],"parameters_en":[{"name":"","range":"1 mg to 5 mg","cmc":"4,6·10⁻³ mg"},{"name":"","range":"10 mg","cmc":"4,9·10⁻³ mg"},{"name":"","range":"20 mg","cmc":"5,3·10⁻³ mg"},{"name":"","range":"50 mg","cmc":"5,8·10⁻³ mg"},{"name":"","range":"100 mg","cmc":"6,8·10⁻³ mg"},{"name":"","range":"200 mg","cmc":"8,0·10⁻³ mg"},{"name":"","range":"500 mg","cmc":"1,0·10⁻² mg"},{"name":"","range":"1 g","cmc":"1,1·10⁻² mg"},{"name":"","range":"2 g","cmc":"1,4·10⁻² mg"},{"name":"","range":"5 g","cmc":"1,8·10⁻² mg"},{"name":"","range":"10 g","cmc":"2,1·10⁻² mg"},{"name":"","range":"20 g","cmc":"2,7·10⁻² mg"},{"name":"","range":"50 g","cmc":"3,4·10⁻² mg"},{"name":"","range":"100 g","cmc":"5,5·10⁻² mg"},{"name":"","range":"200 g","cmc":"1,1·10⁻¹ mg"},{"name":"","range":"500 g","cmc":"8,2·10⁰ mg"},{"name":"","range":"1 kg","cmc":"8,2·10⁰ mg"},{"name":"","range":"2 kg","cmc":"8,3·10⁰ mg"},{"name":"","range":"5 kg","cmc":"8,6·10⁰ mg"},{"name":"","range":"10 kg","cmc":"8,2·10¹ mg"}],"parameters_zh":[{"name":"","range":"1 mg 至 5 mg","cmc":"4,6·10⁻³ mg"},{"name":"","range":"10 mg","cmc":"4,9·10⁻³ mg"},{"name":"","range":"20 mg","cmc":"5,3·10⁻³ mg"},{"name":"","range":"50 mg","cmc":"5,8·10⁻³ mg"},{"name":"","range":"100 mg","cmc":"6,8·10⁻³ mg"},{"name":"","range":"200 mg","cmc":"8,0·10⁻³ mg"},{"name":"","range":"500 mg","cmc":"1,0·10⁻² mg"},{"name":"","range":"1 g","cmc":"1,1·10⁻² mg"},{"name":"","range":"2 g","cmc":"1,4·10⁻² mg"},{"name":"","range":"5 g","cmc":"1,8·10⁻² mg"},{"name":"","range":"10 g","cmc":"2,1·10⁻² mg"},{"name":"","range":"20 g","cmc":"2,7·10⁻² mg"},{"name":"","range":"50 g","cmc":"3,4·10⁻² mg"},{"name":"","range":"100 g","cmc":"5,5·10⁻² mg"},{"name":"","range":"200 g","cmc":"1,1·10⁻¹ mg"},{"name":"","range":"500 g","cmc":"8,2·10⁰ mg"},{"name":"","range":"1 kg","cmc":"8,2·10⁰ mg"},{"name":"","range":"2 kg","cmc":"8,3·10⁰ mg"},{"name":"","range":"5 kg","cmc":"8,6·10⁰ mg"},{"name":"","range":"10 kg","cmc":"8,2·10¹ mg"}],"parameters_cs":[{"name":"","range":"1 mg až 5 mg","cmc":"4,6·10⁻³ mg"},{"name":"","range":"10 mg","cmc":"4,9·10⁻³ mg"},{"name":"","range":"20 mg","cmc":"5,3·10⁻³ mg"},{"name":"","range":"50 mg","cmc":"5,8·10⁻³ mg"},{"name":"","range":"100 mg","cmc":"6,8·10⁻³ mg"},{"name":"","range":"200 mg","cmc":"8,0·10⁻³ mg"},{"name":"","range":"500 mg","cmc":"1,0·10⁻² mg"},{"name":"","range":"1 g","cmc":"1,1·10⁻² mg"},{"name":"","range":"2 g","cmc":"1,4·10⁻² mg"},{"name":"","range":"5 g","cmc":"1,8·10⁻² mg"},{"name":"","range":"10 g","cmc":"2,1·10⁻² mg"},{"name":"","range":"20 g","cmc":"2,7·10⁻² mg"},{"name":"","range":"50 g","cmc":"3,4·10⁻² mg"},{"name":"","range":"100 g","cmc":"5,5·10⁻² mg"},{"name":"","range":"200 g","cmc":"1,1·10⁻¹ mg"},{"name":"","range":"500 g","cmc":"8,2·10⁰ mg"},{"name":"","range":"1 kg","cmc":"8,2·10⁰ mg"},{"name":"","range":"2 kg","cmc":"8,3·10⁰ mg"},{"name":"","range":"5 kg","cmc":"8,6·10⁰ mg"},{"name":"","range":"10 kg","cmc":"8,2·10¹ mg"}],"technique":"Porównanie z odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 na wagach wzorcowych","technique_en":"Comparison with a standard weight (according to OIML R 111-1:2004) of class E2 on reference scales","technique_zh":"在标准天平上与E2级标准砝码比较（依据 OIML R 111-1:2004）","technique_cs":"Porovnání s etalonovým závažím (dle OIML R 111-1:2004) třídy E2 na etalonových vahách","techniques":["Porównanie z odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 na wagach wzorcowych"],"techniques_en":["Comparison with a standard weight (according to OIML R 111-1:2004) of class E2 on reference scales"],"techniques_zh":["在标准天平上与E2级标准砝码比较（依据 OIML R 111-1:2004）"],"techniques_cs":["Porovnání s etalonovým závažím (dle OIML R 111-1:2004) třídy E2 na etalonových vahách"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – masa\nZakres:\nod 1 mg do 5 mg CMC 4,6·10⁻³ mg\n10 mg CMC 4,9·10⁻³ mg\n20 mg CMC 5,3·10⁻³ mg\n50 mg CMC 5,8·10⁻³ mg\n100 mg CMC 6,8·10⁻³ mg\n200 mg CMC 8,0·10⁻³ mg\n500 mg CMC 1,0·10⁻² mg\n1 g CMC 1,1·10⁻² mg\n2 g CMC 1,4·10⁻² mg\n5 g CMC 1,8·10⁻² mg\n10 g CMC 2,1·10⁻² mg\n20 g CMC 2,7·10⁻² mg\n50 g CMC 3,4·10⁻² mg\n100 g CMC 5,5·10⁻² mg\n200 g CMC 1,1·10⁻¹ mg\n500 g CMC 8,2·10⁰ mg\n1 kg CMC 8,2·10⁰ mg\n2 kg CMC 8,3·10⁰ mg\n5 kg CMC 8,6·10⁰ mg\n10 kg CMC 8,2·10¹ mg\nPorównanie z odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 na wagach wzorcowych","reference":"J 62.03.W02","norm_bases":["J 62.03.W02"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: masa","regulatory_area_en":"CMC for the field of measured quantity: Mass","regulatory_area_zh":"被测量领域的CMC：质量","regulatory_area_cs":"CMC pro obor měřené veličiny: Hmotnost","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Odważniki klasy F1, F2, M Wzorcowanie – masa Porównanie z odważnikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 na wagach wzorcowych od 1 mg do 5 mg CMC 4,6·10⁻³ mg 10 mg CMC 4,9·10⁻³ mg 20 mg CMC 5,3·10⁻³ mg 50 mg CMC 5,8·10⁻³ mg 100 mg CMC 6,8·10⁻³ mg 200 mg CMC 8,0·10⁻³ mg 500 mg CMC 1,0·10⁻² mg 1 g CMC 1,1·10⁻² mg 2 g CMC 1,4·10⁻² mg 5 g CMC 1,8·10⁻² mg 10 g CMC 2,1·10⁻² mg 20 g CMC 2,7·10⁻² mg 50 g CMC 3,4·10⁻² mg 100 g CMC 5,5·10⁻² mg 200 g CMC 1,1·10⁻¹ mg 500 g CMC 8,2·10⁰ mg 1 kg CMC 8,2·10⁰ mg 2 kg CMC 8,3·10⁰ mg 5 kg CMC 8,6·10⁰ mg 10 kg CMC 8,2·10¹ mg Závaží třídy F1, F2, M Kalibrace – hmotnost Porovnání s etalonovým závažím (dle OIML R 111-1:2004) třídy E2 na etalonových vahách 1 mg až 5 mg CMC 4,6·10⁻³ mg 10 mg CMC 4,9·10⁻³ mg 20 mg CMC 5,3·10⁻³ mg 50 mg CMC 5,8·10⁻³ mg 100 mg CMC 6,8·10⁻³ mg 200 mg CMC 8,0·10⁻³ mg 500 mg CMC 1,0·10⁻² mg 1 g CMC 1,1·10⁻² mg 2 g CMC 1,4·10⁻² mg 5 g CMC 1,8·10⁻² mg 10 g CMC 2,1·10⁻² mg 20 g CMC 2,7·10⁻² mg 50 g CMC 3,4·10⁻² mg 100 g CMC 5,5·10⁻² mg 200 g CMC 1,1·10⁻¹ mg 500 g CMC 8,2·10⁰ mg 1 kg CMC 8,2·10⁰ mg 2 kg CMC 8,3·10⁰ mg 5 kg CMC 8,6·10⁰ mg 10 kg CMC 8,2·10¹ mg J 62.03.W02 Odwazniki klasy F1, F2, M Wzorcowanie – masa Porownanie z odwaznikiem wzorcowym (wg OIML R 111-1:2004) klasy E2 na wagach wzorcowych od 1 mg do 5 mg CMC 4,6·10⁻³ mg 10 mg CMC 4,9·10⁻³ mg 20 mg CMC 5,3·10⁻³ mg 50 mg CMC 5,8·10⁻³ mg 100 mg CMC 6,8·10⁻³ mg 200 mg CMC 8,0·10⁻³ mg 500 mg CMC 1,0·10⁻² mg 1 g CMC 1,1·10⁻² mg 2 g CMC 1,4·10⁻² mg 5 g CMC 1,8·10⁻² mg 10 g CMC 2,1·10⁻² mg 20 g CMC 2,7·10⁻² mg 50 g CMC 3,4·10⁻² mg 100 g CMC 5,5·10⁻² mg 200 g CMC 1,1·10⁻¹ mg 500 g CMC 8,2·10⁰ mg 1 kg CMC 8,2·10⁰ mg 2 kg CMC 8,3·10⁰ mg 5 kg CMC 8,6·10⁰ mg 10 kg CMC 8,2·10¹ mg Zavazi tridy F1, F2, M Kalibrace – hmotnost Porovnani s etalonovym zavazim (dle OIML R 111-1:2004) tridy E2 na etalonovych vahach 1 mg az 5 mg CMC 4,6·10⁻³ mg 10 mg CMC 4,9·10⁻³ mg 20 mg CMC 5,3·10⁻³ mg 50 mg CMC 5,8·10⁻³ mg 100 mg CMC 6,8·10⁻³ mg 200 mg CMC 8,0·10⁻³ mg 500 mg CMC 1,0·10⁻² mg 1 g CMC 1,1·10⁻² mg 2 g CMC 1,4·10⁻² mg 5 g CMC 1,8·10⁻² mg 10 g CMC 2,1·10⁻² mg 20 g CMC 2,7·10⁻² mg 50 g CMC 3,4·10⁻² mg 100 g CMC 5,5·10⁻² mg 200 g CMC 1,1·10⁻¹ mg 500 g CMC 8,2·10⁰ mg 1 kg CMC 8,2·10⁰ mg 2 kg CMC 8,3·10⁰ mg 5 kg CMC 8,6·10⁰ mg 10 kg CMC 8,2·10¹ mg J 62.03.W02","search_en":"F1, F2, M class weights Calibration – mass Comparison with a standard weight (according to OIML R 111-1:2004) of class E2 on reference scales 1 mg to 5 mg CMC 4,6·10⁻³ mg 10 mg CMC 4,9·10⁻³ mg 20 mg CMC 5,3·10⁻³ mg 50 mg CMC 5,8·10⁻³ mg 100 mg CMC 6,8·10⁻³ mg 200 mg CMC 8,0·10⁻³ mg 500 mg CMC 1,0·10⁻² mg 1 g CMC 1,1·10⁻² mg 2 g CMC 1,4·10⁻² mg 5 g CMC 1,8·10⁻² mg 10 g CMC 2,1·10⁻² mg 20 g CMC 2,7·10⁻² mg 50 g CMC 3,4·10⁻² mg 100 g CMC 5,5·10⁻² mg 200 g CMC 1,1·10⁻¹ mg 500 g CMC 8,2·10⁰ mg 1 kg CMC 8,2·10⁰ mg 2 kg CMC 8,3·10⁰ mg 5 kg CMC 8,6·10⁰ mg 10 kg CMC 8,2·10¹ mg J 62.03.W02","search_zh":"F1、F2、M 级砝码 校准 – 质量 在标准天平上与E2级标准砝码比较（依据 OIML R 111-1:2004） 1 mg 至 5 mg CMC 4,6·10⁻³ mg 10 mg CMC 4,9·10⁻³ mg 20 mg CMC 5,3·10⁻³ mg 50 mg CMC 5,8·10⁻³ mg 100 mg CMC 6,8·10⁻³ mg 200 mg CMC 8,0·10⁻³ mg 500 mg CMC 1,0·10⁻² mg 1 g CMC 1,1·10⁻² mg 2 g CMC 1,4·10⁻² mg 5 g CMC 1,8·10⁻² mg 10 g CMC 2,1·10⁻² mg 20 g CMC 2,7·10⁻² mg 50 g CMC 3,4·10⁻² mg 100 g CMC 5,5·10⁻² mg 200 g CMC 1,1·10⁻¹ mg 500 g CMC 8,2·10⁰ mg 1 kg CMC 8,2·10⁰ mg 2 kg CMC 8,3·10⁰ mg 5 kg CMC 8,6·10⁰ mg 10 kg CMC 8,2·10¹ mg J 62.03.W02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1a3d26f34f176e14861f7593","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Wartość skuteczna prostoliniowych drgań mechanicznych o przebiegu harmonicznym / wibrometry, czujniki drgań","test_object_en":"Effective value of linear harmonic mechanical vibrations / Vibrometers, vibration sensors","test_object_zh":"直线简谐机械振动的有效值 / 振动计、振动传感器","test_object_cs":"Efektivní hodnota přímočarých mechanických vibrací harmonického průběhu / Vibrometry, snímače vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"przyspieszenie; 30 Hz do 1 000 Hz","range":"od 3 m·s⁻² do 60 m·s⁻²","cmc":"2,7 %"},{"name":"prędkość; 30 Hz do 1 000 Hz","range":"od 0,5 m·s⁻¹ do 320 m·s⁻¹","cmc":"2,7 %"},{"name":"wychylenie; 30 Hz do 1 000 Hz","range":"od 0 µm do 4800 µm","cmc":"2,7 %"}],"parameters_en":[{"name":"acceleration; 30 Hz to 1 000 Hz","range":"3 m·s⁻² to 60 m·s⁻²","cmc":"2,7 %"},{"name":"velocity; 30 Hz to 1 000 Hz","range":"0,5 m·s⁻¹ to 320 m·s⁻¹","cmc":"2,7 %"},{"name":"amplitude; 30 Hz to 1 000 Hz","range":"0 µm to 4800 µm","cmc":"2,7 %"}],"parameters_zh":[{"name":"加速度；30 Hz 至 1 000 Hz","range":"3 m·s⁻² 至 60 m·s⁻²","cmc":"2,7 %"},{"name":"速度；30 Hz 至 1 000 Hz","range":"0,5 m·s⁻¹ 至 320 m·s⁻¹","cmc":"2,7 %"},{"name":"位移；30 Hz 至 1 000 Hz","range":"0 µm 至 4800 µm","cmc":"2,7 %"}],"parameters_cs":[{"name":"zrychlení; 30 Hz až 1 000 Hz","range":"3 m·s⁻² až 60 m·s⁻²","cmc":"2,7 %"},{"name":"rychlost; 30 Hz až 1 000 Hz","range":"0,5 m·s⁻¹ až 320 m·s⁻¹","cmc":"2,7 %"},{"name":"výchylka; 30 Hz až 1 000 Hz","range":"0 µm až 4800 µm","cmc":"2,7 %"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a reference standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a reference standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\nZakres:\nprzyspieszenie; 30 Hz do 1 000 Hz od 3 m·s⁻² do 60 m·s⁻² CMC 2,7 %\nprędkość; 30 Hz do 1 000 Hz od 0,5 m·s⁻¹ do 320 m·s⁻¹ CMC 2,7 %\nwychylenie; 30 Hz do 1 000 Hz od 0 µm do 4800 µm CMC 2,7 %\nPorównanie z wzorcem","reference":"J 62.09.V01","norm_bases":["J 62.09.V01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wartość skuteczna prostoliniowych drgań mechanicznych o przebiegu harmonicznym / wibrometry, czujniki drgań Wzorcowanie – ruch mechaniczny Porównanie z wzorcem przyspieszenie; 30 Hz do 1 000 Hz od 3 m·s⁻² do 60 m·s⁻² CMC 2,7 % prędkość; 30 Hz do 1 000 Hz od 0,5 m·s⁻¹ do 320 m·s⁻¹ CMC 2,7 % wychylenie; 30 Hz do 1 000 Hz od 0 µm do 4800 µm CMC 2,7 % Efektivní hodnota přímočarých mechanických vibrací harmonického průběhu / Vibrometry, snímače vibrací Kalibrace – mechanický pohyb Porovnání s etalonem zrychlení; 30 Hz až 1 000 Hz 3 m·s⁻² až 60 m·s⁻² CMC 2,7 % rychlost; 30 Hz až 1 000 Hz 0,5 m·s⁻¹ až 320 m·s⁻¹ CMC 2,7 % výchylka; 30 Hz až 1 000 Hz 0 µm až 4800 µm CMC 2,7 % J 62.09.V01 Wartosc skuteczna prostoliniowych drgan mechanicznych o przebiegu harmonicznym / wibrometry, czujniki drgan Wzorcowanie – ruch mechaniczny Porownanie z wzorcem przyspieszenie; 30 Hz do 1 000 Hz od 3 m·s⁻² do 60 m·s⁻² CMC 2,7 % predkosc; 30 Hz do 1 000 Hz od 0,5 m·s⁻¹ do 320 m·s⁻¹ CMC 2,7 % wychylenie; 30 Hz do 1 000 Hz od 0 µm do 4800 µm CMC 2,7 % Efektivni hodnota primocarych mechanickych vibraci harmonickeho prubehu / Vibrometry, snimace vibraci Kalibrace – mechanicky pohyb Porovnani s etalonem zrychleni; 30 Hz az 1 000 Hz 3 m·s⁻² az 60 m·s⁻² CMC 2,7 % rychlost; 30 Hz az 1 000 Hz 0,5 m·s⁻¹ az 320 m·s⁻¹ CMC 2,7 % vychylka; 30 Hz az 1 000 Hz 0 µm az 4800 µm CMC 2,7 % J 62.09.V01","search_en":"Effective value of linear harmonic mechanical vibrations / Vibrometers, vibration sensors Calibration – mechanical motion Comparison with a reference standard acceleration; 30 Hz to 1 000 Hz 3 m·s⁻² to 60 m·s⁻² CMC 2,7 % velocity; 30 Hz to 1 000 Hz 0,5 m·s⁻¹ to 320 m·s⁻¹ CMC 2,7 % amplitude; 30 Hz to 1 000 Hz 0 µm to 4800 µm CMC 2,7 % J 62.09.V01","search_zh":"直线简谐机械振动的有效值 / 振动计、振动传感器 校准 – 机械运动 与标准器比较 加速度；30 Hz 至 1 000 Hz 3 m·s⁻² 至 60 m·s⁻² CMC 2,7 % 速度；30 Hz 至 1 000 Hz 0,5 m·s⁻¹ 至 320 m·s⁻¹ CMC 2,7 % 位移；30 Hz 至 1 000 Hz 0 µm 至 4800 µm CMC 2,7 % J 62.09.V01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"952f655de237d7219254ce54","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Czułość czujników drgań","test_object_en":"Sensitivity of vibration sensors","test_object_zh":"振动传感器灵敏度","test_object_cs":"Citlivost snímačů vibrací","methodology":"Wzorcowanie – ruch mechaniczny","methodology_en":"Calibration – mechanical motion","methodology_zh":"校准 – 机械运动","methodology_cs":"Kalibrace – mechanický pohyb","parameters":[{"name":"30 Hz do 1 000 Hz","range":"od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻²","cmc":"2,7 %"}],"parameters_en":[{"name":"30 Hz to 1 000 Hz","range":"0,01 mV/m·s⁻² to 10 000 mV/m·s⁻²","cmc":"2,7 %"}],"parameters_zh":[{"name":"30 Hz 至 1 000 Hz","range":"0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻²","cmc":"2,7 %"}],"parameters_cs":[{"name":"30 Hz až 1 000 Hz","range":"0,01 mV/m·s⁻² až 10 000 mV/m·s⁻²","cmc":"2,7 %"}],"technique":"Porównanie z wzorcem","technique_en":"Comparison with a reference standard","technique_zh":"与标准器比较","technique_cs":"Porovnání s etalonem","techniques":["Porównanie z wzorcem"],"techniques_en":["Comparison with a reference standard"],"techniques_zh":["与标准器比较"],"techniques_cs":["Porovnání s etalonem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ruch mechaniczny\n30 Hz do 1 000 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,7 %\nPorównanie z wzorcem","reference":"J 62.09.V01","norm_bases":["J 62.09.V01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ruch mechaniczny","regulatory_area_en":"CMC for the field of measured quantity: Mechanical motion","regulatory_area_zh":"被测量领域的CMC：机械运动","regulatory_area_cs":"CMC pro obor měřené veličiny: Mechanický pohyb","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czułość czujników drgań Wzorcowanie – ruch mechaniczny Porównanie z wzorcem 30 Hz do 1 000 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,7 % Citlivost snímačů vibrací Kalibrace – mechanický pohyb Porovnání s etalonem 30 Hz až 1 000 Hz 0,01 mV/m·s⁻² až 10 000 mV/m·s⁻² CMC 2,7 % J 62.09.V01 Czulosc czujnikow drgan Wzorcowanie – ruch mechaniczny Porownanie z wzorcem 30 Hz do 1 000 Hz od 0,01 mV/m·s⁻² do 10 000 mV/m·s⁻² CMC 2,7 % Citlivost snimacu vibraci Kalibrace – mechanicky pohyb Porovnani s etalonem 30 Hz az 1 000 Hz 0,01 mV/m·s⁻² az 10 000 mV/m·s⁻² CMC 2,7 % J 62.09.V01","search_en":"Sensitivity of vibration sensors Calibration – mechanical motion Comparison with a reference standard 30 Hz to 1 000 Hz 0,01 mV/m·s⁻² to 10 000 mV/m·s⁻² CMC 2,7 % J 62.09.V01","search_zh":"振动传感器灵敏度 校准 – 机械运动 与标准器比较 30 Hz 至 1 000 Hz 0,01 mV/m·s⁻² 至 10 000 mV/m·s⁻² CMC 2,7 % J 62.09.V01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"38cf7c64c7d65056e5fa12ad","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne","test_object_en":"Torque / torque wrenches, torque screwdrivers","test_object_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀","test_object_cs":"Moment síly / momentové klíče, momentové šroubováky","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 1 N·m do 1000 N·m","cmc":"0,7 %"}],"parameters_en":[{"name":"","range":"1 N·m to 1000 N·m","cmc":"0,7 %"}],"parameters_zh":[{"name":"","range":"1 N·m 至 1000 N·m","cmc":"0,7 %"}],"parameters_cs":[{"name":"","range":"1 N·m až 1000 N·m","cmc":"0,7 %"}],"technique":"Wzorcowanie wzorcowym urządzeniem momentu siły","technique_en":"Calibration with a reference torque device","technique_zh":"用标准扭矩装置校准","technique_cs":"Kalibrace etalonovým zařízením momentu síly","techniques":["Wzorcowanie wzorcowym urządzeniem momentu siły"],"techniques_en":["Calibration with a reference torque device"],"techniques_zh":["用标准扭矩装置校准"],"techniques_cs":["Kalibrace etalonovým zařízením momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nod 1 N·m do 1000 N·m CMC 0,7 %\nWzorcowanie wzorcowym urządzeniem momentu siły","reference":"J 62.03.S01","norm_bases":["J 62.03.S01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne Wzorcowanie – moment siły Wzorcowanie wzorcowym urządzeniem momentu siły od 1 N·m do 1000 N·m CMC 0,7 % Moment síly / momentové klíče, momentové šroubováky Kalibrace – moment síly Kalibrace etalonovým zařízením momentu síly 1 N·m až 1000 N·m CMC 0,7 % J 62.03.S01 Moment sily / klucze dynamometryczne, wkretaki dynamometryczne Wzorcowanie – moment sily Wzorcowanie wzorcowym urzadzeniem momentu sily od 1 N·m do 1000 N·m CMC 0,7 % Moment sily / momentove klice, momentove sroubovaky Kalibrace – moment sily Kalibrace etalonovym zarizenim momentu sily 1 N·m az 1000 N·m CMC 0,7 % J 62.03.S01","search_en":"Torque / torque wrenches, torque screwdrivers Calibration – torque Calibration with a reference torque device 1 N·m to 1000 N·m CMC 0,7 % J 62.03.S01","search_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀 校准 – 扭矩 用标准扭矩装置校准 1 N·m 至 1000 N·m CMC 0,7 % J 62.03.S01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"39a78069d26ac5da1bcef74d","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne","test_object_en":"Torque / torque wrenches, torque screwdrivers","test_object_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀","test_object_cs":"Moment síly / momentové klíče, momentové šroubováky","methodology":"Wzorcowanie – moment siły","methodology_en":"Calibration – torque","methodology_zh":"校准 – 扭矩","methodology_cs":"Kalibrace – moment síly","parameters":[{"name":"","range":"od 1 N·m do 1000 N·m","cmc":"0,7 %"}],"parameters_en":[{"name":"","range":"1 N·m to 1000 N·m","cmc":"0,7 %"}],"parameters_zh":[{"name":"","range":"1 N·m 至 1000 N·m","cmc":"0,7 %"}],"parameters_cs":[{"name":"","range":"1 N·m až 1000 N·m","cmc":"0,7 %"}],"technique":"Wzorcowanie wzorcowym urządzeniem momentu siły","technique_en":"Calibration with a reference torque device","technique_zh":"用标准扭矩装置校准","technique_cs":"Kalibrace etalonovým zařízením momentu síly","techniques":["Wzorcowanie wzorcowym urządzeniem momentu siły"],"techniques_en":["Calibration with a reference torque device"],"techniques_zh":["用标准扭矩装置校准"],"techniques_cs":["Kalibrace etalonovým zařízením momentu síly"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – moment siły\nod 1 N·m do 1000 N·m CMC 0,7 %\nWzorcowanie wzorcowym urządzeniem momentu siły","reference":"J 62.03.S01","norm_bases":["J 62.03.S01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: moment siły","regulatory_area_en":"CMC for the field of measured quantity: Torque","regulatory_area_zh":"被测量领域的CMC：扭矩","regulatory_area_cs":"CMC pro obor měřené veličiny: Moment síly","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moment siły / klucze dynamometryczne, wkrętaki dynamometryczne Wzorcowanie – moment siły Wzorcowanie wzorcowym urządzeniem momentu siły od 1 N·m do 1000 N·m CMC 0,7 % Moment síly / momentové klíče, momentové šroubováky Kalibrace – moment síly Kalibrace etalonovým zařízením momentu síly 1 N·m až 1000 N·m CMC 0,7 % J 62.03.S01 Moment sily / klucze dynamometryczne, wkretaki dynamometryczne Wzorcowanie – moment sily Wzorcowanie wzorcowym urzadzeniem momentu sily od 1 N·m do 1000 N·m CMC 0,7 % Moment sily / momentove klice, momentove sroubovaky Kalibrace – moment sily Kalibrace etalonovym zarizenim momentu sily 1 N·m az 1000 N·m CMC 0,7 % J 62.03.S01","search_en":"Torque / torque wrenches, torque screwdrivers Calibration – torque Calibration with a reference torque device 1 N·m to 1000 N·m CMC 0,7 % J 62.03.S01","search_zh":"扭矩 / 扭矩扳手、扭矩螺丝刀 校准 – 扭矩 用标准扭矩装置校准 1 N·m 至 1000 N·m CMC 0,7 % J 62.03.S01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5ed938d2a6f66f84fc966d0f","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"gaz, ciśnienie bezwzględne","range":"od 0 kPa do 63 kPa","cmc":"7,4 Pa"},{"name":"gaz, ciśnienie bezwzględne","range":"od 63 kPa do 7 MPa","cmc":"0,007 %"},{"name":"gaz, nadciśnienie","range":"od −100 kPa do −72 kPa","cmc":"0,01 %"},{"name":"gaz, nadciśnienie","range":"od −72 kPa do 0 kPa","cmc":"8,5 Pa"},{"name":"gaz, nadciśnienie","range":"od 16 kPa do 72 kPa","cmc":"8,5 Pa"},{"name":"gaz, nadciśnienie","range":"od 72 kPa do 7 MPa","cmc":"0,007 %"},{"name":"gaz, ciśnienie barometryczne","range":"od 70 kPa do 110 kPa","cmc":"0,011 %"}],"parameters_en":[{"name":"gas, absolute pressure","range":"0 kPa to 63 kPa","cmc":"7,4 Pa"},{"name":"gas, absolute pressure","range":"63 kPa to 7 MPa","cmc":"0,007 %"},{"name":"gas, gauge pressure","range":"−100 kPa to −72 kPa","cmc":"0,01 %"},{"name":"gas, gauge pressure","range":"−72 kPa to 0 kPa","cmc":"8,5 Pa"},{"name":"gas, gauge pressure","range":"16 kPa to 72 kPa","cmc":"8,5 Pa"},{"name":"gas, gauge pressure","range":"72 kPa to 7 MPa","cmc":"0,007 %"},{"name":"gas, barometric pressure","range":"70 kPa to 110 kPa","cmc":"0,011 %"}],"parameters_zh":[{"name":"气体，绝对压力","range":"0 kPa 至 63 kPa","cmc":"7,4 Pa"},{"name":"气体，绝对压力","range":"63 kPa 至 7 MPa","cmc":"0,007 %"},{"name":"气体，表压","range":"−100 kPa 至 −72 kPa","cmc":"0,01 %"},{"name":"气体，表压","range":"−72 kPa 至 0 kPa","cmc":"8,5 Pa"},{"name":"气体，表压","range":"16 kPa 至 72 kPa","cmc":"8,5 Pa"},{"name":"气体，表压","range":"72 kPa 至 7 MPa","cmc":"0,007 %"},{"name":"气体，大气压力","range":"70 kPa 至 110 kPa","cmc":"0,011 %"}],"parameters_cs":[{"name":"plyn, absolutní tlak","range":"0 kPa až 63 kPa","cmc":"7,4 Pa"},{"name":"plyn, absolutní tlak","range":"63 kPa až 7 MPa","cmc":"0,007 %"},{"name":"plyn, přetlak","range":"−100 kPa až −72 kPa","cmc":"0,01 %"},{"name":"plyn, přetlak","range":"−72 kPa až 0 kPa","cmc":"8,5 Pa"},{"name":"plyn, přetlak","range":"16 kPa až 72 kPa","cmc":"8,5 Pa"},{"name":"plyn, přetlak","range":"72 kPa až 7 MPa","cmc":"0,007 %"},{"name":"plyn, barometrický tlak","range":"70 kPa až 110 kPa","cmc":"0,011 %"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a reference digital manometer","technique_zh":"与标准数字压力计比较","technique_cs":"Porovnání s etalonovým digitálním tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a reference digital manometer"],"techniques_zh":["与标准数字压力计比较"],"techniques_cs":["Porovnání s etalonovým digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\ngaz, ciśnienie bezwzględne od 0 kPa do 63 kPa CMC 7,4 Pa\ngaz, ciśnienie bezwzględne od 63 kPa do 7 MPa CMC 0,007 %\ngaz, nadciśnienie od −100 kPa do −72 kPa CMC 0,01 %\ngaz, nadciśnienie od −72 kPa do 0 kPa CMC 8,5 Pa\ngaz, nadciśnienie od 16 kPa do 72 kPa CMC 8,5 Pa\ngaz, nadciśnienie od 72 kPa do 7 MPa CMC 0,007 %\ngaz, ciśnienie barometryczne od 70 kPa do 110 kPa CMC 0,011 %\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"J62.03.P01, J62.03.P02, J62.03.P03","norm_bases":["J62.03.P01","J62.03.P02","J62.03.P03"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym gaz, ciśnienie bezwzględne od 0 kPa do 63 kPa CMC 7,4 Pa gaz, ciśnienie bezwzględne od 63 kPa do 7 MPa CMC 0,007 % gaz, nadciśnienie od −100 kPa do −72 kPa CMC 0,01 % gaz, nadciśnienie od −72 kPa do 0 kPa CMC 8,5 Pa gaz, nadciśnienie od 16 kPa do 72 kPa CMC 8,5 Pa gaz, nadciśnienie od 72 kPa do 7 MPa CMC 0,007 % gaz, ciśnienie barometryczne od 70 kPa do 110 kPa CMC 0,011 % Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku Kalibrace – tlak Porovnání s etalonovým digitálním tlakoměrem plyn, absolutní tlak 0 kPa až 63 kPa CMC 7,4 Pa plyn, absolutní tlak 63 kPa až 7 MPa CMC 0,007 % plyn, přetlak −100 kPa až −72 kPa CMC 0,01 % plyn, přetlak −72 kPa až 0 kPa CMC 8,5 Pa plyn, přetlak 16 kPa až 72 kPa CMC 8,5 Pa plyn, přetlak 72 kPa až 7 MPa CMC 0,007 % plyn, barometrický tlak 70 kPa až 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia, w tym roznicowe, tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym gaz, cisnienie bezwzgledne od 0 kPa do 63 kPa CMC 7,4 Pa gaz, cisnienie bezwzgledne od 63 kPa do 7 MPa CMC 0,007 % gaz, nadcisnienie od −100 kPa do −72 kPa CMC 0,01 % gaz, nadcisnienie od −72 kPa do 0 kPa CMC 8,5 Pa gaz, nadcisnienie od 16 kPa do 72 kPa CMC 8,5 Pa gaz, nadcisnienie od 72 kPa do 7 MPa CMC 0,007 % gaz, cisnienie barometryczne od 70 kPa do 110 kPa CMC 0,011 % Deformacni a cislicove tlakomery, prevodniky tlaku vcetne diferencnich, merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym digitalnim tlakomerem plyn, absolutni tlak 0 kPa az 63 kPa CMC 7,4 Pa plyn, absolutni tlak 63 kPa az 7 MPa CMC 0,007 % plyn, pretlak −100 kPa az −72 kPa CMC 0,01 % plyn, pretlak −72 kPa az 0 kPa CMC 8,5 Pa plyn, pretlak 16 kPa az 72 kPa CMC 8,5 Pa plyn, pretlak 72 kPa az 7 MPa CMC 0,007 % plyn, barometricky tlak 70 kPa az 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03","search_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains Calibration – pressure Comparison with a reference digital manometer gas, absolute pressure 0 kPa to 63 kPa CMC 7,4 Pa gas, absolute pressure 63 kPa to 7 MPa CMC 0,007 % gas, gauge pressure −100 kPa to −72 kPa CMC 0,01 % gas, gauge pressure −72 kPa to 0 kPa CMC 8,5 Pa gas, gauge pressure 16 kPa to 72 kPa CMC 8,5 Pa gas, gauge pressure 72 kPa to 7 MPa CMC 0,007 % gas, barometric pressure 70 kPa to 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03","search_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链 校准 – 压力 与标准数字压力计比较 气体，绝对压力 0 kPa 至 63 kPa CMC 7,4 Pa 气体，绝对压力 63 kPa 至 7 MPa CMC 0,007 % 气体，表压 −100 kPa 至 −72 kPa CMC 0,01 % 气体，表压 −72 kPa 至 0 kPa CMC 8,5 Pa 气体，表压 16 kPa 至 72 kPa CMC 8,5 Pa 气体，表压 72 kPa 至 7 MPa CMC 0,007 % 气体，大气压力 70 kPa 至 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"422089f646a93d8d41e0c579","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"gaz, ciśnienie bezwzględne","range":"od 0 kPa do 63 kPa","cmc":"7,4 Pa"},{"name":"gaz, ciśnienie bezwzględne","range":"od 63 kPa do 7 MPa","cmc":"0,007 %"},{"name":"gaz, nadciśnienie","range":"od −100 kPa do −72 kPa","cmc":"0,01 %"},{"name":"gaz, nadciśnienie","range":"od −72 kPa do 0 kPa","cmc":"8,5 Pa"},{"name":"gaz, nadciśnienie","range":"od 16 kPa do 72 kPa","cmc":"8,5 Pa"},{"name":"gaz, nadciśnienie","range":"od 72 kPa do 7 MPa","cmc":"0,007 %"},{"name":"gaz, ciśnienie barometryczne","range":"od 70 kPa do 110 kPa","cmc":"0,011 %"}],"parameters_en":[{"name":"gas, absolute pressure","range":"0 kPa to 63 kPa","cmc":"7,4 Pa"},{"name":"gas, absolute pressure","range":"63 kPa to 7 MPa","cmc":"0,007 %"},{"name":"gas, gauge pressure","range":"−100 kPa to −72 kPa","cmc":"0,01 %"},{"name":"gas, gauge pressure","range":"−72 kPa to 0 kPa","cmc":"8,5 Pa"},{"name":"gas, gauge pressure","range":"16 kPa to 72 kPa","cmc":"8,5 Pa"},{"name":"gas, gauge pressure","range":"72 kPa to 7 MPa","cmc":"0,007 %"},{"name":"gas, barometric pressure","range":"70 kPa to 110 kPa","cmc":"0,011 %"}],"parameters_zh":[{"name":"气体，绝对压力","range":"0 kPa 至 63 kPa","cmc":"7,4 Pa"},{"name":"气体，绝对压力","range":"63 kPa 至 7 MPa","cmc":"0,007 %"},{"name":"气体，表压","range":"−100 kPa 至 −72 kPa","cmc":"0,01 %"},{"name":"气体，表压","range":"−72 kPa 至 0 kPa","cmc":"8,5 Pa"},{"name":"气体，表压","range":"16 kPa 至 72 kPa","cmc":"8,5 Pa"},{"name":"气体，表压","range":"72 kPa 至 7 MPa","cmc":"0,007 %"},{"name":"气体，大气压力","range":"70 kPa 至 110 kPa","cmc":"0,011 %"}],"parameters_cs":[{"name":"plyn, absolutní tlak","range":"0 kPa až 63 kPa","cmc":"7,4 Pa"},{"name":"plyn, absolutní tlak","range":"63 kPa až 7 MPa","cmc":"0,007 %"},{"name":"plyn, přetlak","range":"−100 kPa až −72 kPa","cmc":"0,01 %"},{"name":"plyn, přetlak","range":"−72 kPa až 0 kPa","cmc":"8,5 Pa"},{"name":"plyn, přetlak","range":"16 kPa až 72 kPa","cmc":"8,5 Pa"},{"name":"plyn, přetlak","range":"72 kPa až 7 MPa","cmc":"0,007 %"},{"name":"plyn, barometrický tlak","range":"70 kPa až 110 kPa","cmc":"0,011 %"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem cyfrowym","technique_en":"Comparison with a reference digital manometer","technique_zh":"与标准数字压力计比较","technique_cs":"Porovnání s etalonovým digitálním tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem cyfrowym"],"techniques_en":["Comparison with a reference digital manometer"],"techniques_zh":["与标准数字压力计比较"],"techniques_cs":["Porovnání s etalonovým digitálním tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\ngaz, ciśnienie bezwzględne od 0 kPa do 63 kPa CMC 7,4 Pa\ngaz, ciśnienie bezwzględne od 63 kPa do 7 MPa CMC 0,007 %\ngaz, nadciśnienie od −100 kPa do −72 kPa CMC 0,01 %\ngaz, nadciśnienie od −72 kPa do 0 kPa CMC 8,5 Pa\ngaz, nadciśnienie od 16 kPa do 72 kPa CMC 8,5 Pa\ngaz, nadciśnienie od 72 kPa do 7 MPa CMC 0,007 %\ngaz, ciśnienie barometryczne od 70 kPa do 110 kPa CMC 0,011 %\nPorównanie z wzorcowym ciśnieniomierzem cyfrowym","reference":"J62.03.P01, J62.03.P02, J62.03.P03","norm_bases":["J62.03.P01","J62.03.P02","J62.03.P03"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem cyfrowym gaz, ciśnienie bezwzględne od 0 kPa do 63 kPa CMC 7,4 Pa gaz, ciśnienie bezwzględne od 63 kPa do 7 MPa CMC 0,007 % gaz, nadciśnienie od −100 kPa do −72 kPa CMC 0,01 % gaz, nadciśnienie od −72 kPa do 0 kPa CMC 8,5 Pa gaz, nadciśnienie od 16 kPa do 72 kPa CMC 8,5 Pa gaz, nadciśnienie od 72 kPa do 7 MPa CMC 0,007 % gaz, ciśnienie barometryczne od 70 kPa do 110 kPa CMC 0,011 % Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku Kalibrace – tlak Porovnání s etalonovým digitálním tlakoměrem plyn, absolutní tlak 0 kPa až 63 kPa CMC 7,4 Pa plyn, absolutní tlak 63 kPa až 7 MPa CMC 0,007 % plyn, přetlak −100 kPa až −72 kPa CMC 0,01 % plyn, přetlak −72 kPa až 0 kPa CMC 8,5 Pa plyn, přetlak 16 kPa až 72 kPa CMC 8,5 Pa plyn, přetlak 72 kPa až 7 MPa CMC 0,007 % plyn, barometrický tlak 70 kPa až 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia, w tym roznicowe, tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem cyfrowym gaz, cisnienie bezwzgledne od 0 kPa do 63 kPa CMC 7,4 Pa gaz, cisnienie bezwzgledne od 63 kPa do 7 MPa CMC 0,007 % gaz, nadcisnienie od −100 kPa do −72 kPa CMC 0,01 % gaz, nadcisnienie od −72 kPa do 0 kPa CMC 8,5 Pa gaz, nadcisnienie od 16 kPa do 72 kPa CMC 8,5 Pa gaz, nadcisnienie od 72 kPa do 7 MPa CMC 0,007 % gaz, cisnienie barometryczne od 70 kPa do 110 kPa CMC 0,011 % Deformacni a cislicove tlakomery, prevodniky tlaku vcetne diferencnich, merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym digitalnim tlakomerem plyn, absolutni tlak 0 kPa az 63 kPa CMC 7,4 Pa plyn, absolutni tlak 63 kPa az 7 MPa CMC 0,007 % plyn, pretlak −100 kPa az −72 kPa CMC 0,01 % plyn, pretlak −72 kPa az 0 kPa CMC 8,5 Pa plyn, pretlak 16 kPa az 72 kPa CMC 8,5 Pa plyn, pretlak 72 kPa az 7 MPa CMC 0,007 % plyn, barometricky tlak 70 kPa az 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03","search_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains Calibration – pressure Comparison with a reference digital manometer gas, absolute pressure 0 kPa to 63 kPa CMC 7,4 Pa gas, absolute pressure 63 kPa to 7 MPa CMC 0,007 % gas, gauge pressure −100 kPa to −72 kPa CMC 0,01 % gas, gauge pressure −72 kPa to 0 kPa CMC 8,5 Pa gas, gauge pressure 16 kPa to 72 kPa CMC 8,5 Pa gas, gauge pressure 72 kPa to 7 MPa CMC 0,007 % gas, barometric pressure 70 kPa to 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03","search_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链 校准 – 压力 与标准数字压力计比较 气体，绝对压力 0 kPa 至 63 kPa CMC 7,4 Pa 气体，绝对压力 63 kPa 至 7 MPa CMC 0,007 % 气体，表压 −100 kPa 至 −72 kPa CMC 0,01 % 气体，表压 −72 kPa 至 0 kPa CMC 8,5 Pa 气体，表压 16 kPa 至 72 kPa CMC 8,5 Pa 气体，表压 72 kPa 至 7 MPa CMC 0,007 % 气体，大气压力 70 kPa 至 110 kPa CMC 0,011 % J62.03.P01, J62.03.P02, J62.03.P03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"32fb9436dccbb0a6fa124285","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"gaz, nadciśnienie","range":"od 0 Pa do 500 Pa","cmc":"0,2 Pa"},{"name":"gaz, nadciśnienie","range":"od 0,5 kPa do 16 kPa","cmc":"0,027 %"},{"name":"gaz, nadciśnienie","range":"od 7 MPa do 20 MPa","cmc":"0,005 %"},{"name":"gaz, różnica ciśnień przy ciśnieniu statycznym (0,1 do 20,1) MPa","range":"od 0 kPa do 500 kPa","cmc":"0,014 %"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 0 kPa do 350 kPa","cmc":"0,042 kPa"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 350 kPa do 3 MPa","cmc":"0,009 %"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 3 MPa do 10 MPa","cmc":"0,46 kPa"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 10 MPa do 100 MPa","cmc":"0,005 %"}],"parameters_en":[{"name":"gas, gauge pressure","range":"0 Pa to 500 Pa","cmc":"0,2 Pa"},{"name":"gas, gauge pressure","range":"0,5 kPa to 16 kPa","cmc":"0,027 %"},{"name":"gas, gauge pressure","range":"7 MPa to 20 MPa","cmc":"0,005 %"},{"name":"gas, pressure difference at stat. pressure (0.1 to 20.1) MPa","range":"0 kPa to 500 kPa","cmc":"0,014 %"},{"name":"oil, gauge pressure, absolute pressure","range":"0 kPa to 350 kPa","cmc":"0,042 kPa"},{"name":"oil, gauge pressure, absolute pressure","range":"350 kPa to 3 MPa","cmc":"0,009 %"},{"name":"oil, gauge pressure, absolute pressure","range":"3 MPa to 10 MPa","cmc":"0,46 kPa"},{"name":"oil, gauge pressure, absolute pressure","range":"10 MPa to 100 MPa","cmc":"0,005 %"}],"parameters_zh":[{"name":"气体，表压","range":"0 Pa 至 500 Pa","cmc":"0,2 Pa"},{"name":"气体，表压","range":"0,5 kPa 至 16 kPa","cmc":"0,027 %"},{"name":"气体，表压","range":"7 MPa 至 20 MPa","cmc":"0,005 %"},{"name":"气体，静压 (0,1 至 20,1) MPa 下的压差","range":"0 kPa 至 500 kPa","cmc":"0,014 %"},{"name":"油，表压、绝对压力","range":"0 kPa 至 350 kPa","cmc":"0,042 kPa"},{"name":"油，表压、绝对压力","range":"350 kPa 至 3 MPa","cmc":"0,009 %"},{"name":"油，表压、绝对压力","range":"3 MPa 至 10 MPa","cmc":"0,46 kPa"},{"name":"油，表压、绝对压力","range":"10 MPa 至 100 MPa","cmc":"0,005 %"}],"parameters_cs":[{"name":"plyn, přetlak","range":"0 Pa až 500 Pa","cmc":"0,2 Pa"},{"name":"plyn, přetlak","range":"0,5 kPa až 16 kPa","cmc":"0,027 %"},{"name":"plyn, přetlak","range":"7 MPa až 20 MPa","cmc":"0,005 %"},{"name":"plyn, tlaková diference při stat. tlaku (0,1 až 20,1) MPa","range":"0 kPa až 500 kPa","cmc":"0,014 %"},{"name":"olej, přetlak, absolutní tlak","range":"0 kPa až 350 kPa","cmc":"0,042 kPa"},{"name":"olej, přetlak, absolutní tlak","range":"350 kPa až 3 MPa","cmc":"0,009 %"},{"name":"olej, přetlak, absolutní tlak","range":"3 MPa až 10 MPa","cmc":"0,46 kPa"},{"name":"olej, přetlak, absolutní tlak","range":"10 MPa až 100 MPa","cmc":"0,005 %"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym","technique_en":"Comparison with a standard piston pressure gauge","technique_zh":"与标准活塞式压力计比较","technique_cs":"Porovnání s etalonovým pístovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym"],"techniques_en":["Comparison with a standard piston pressure gauge"],"techniques_zh":["与标准活塞式压力计比较"],"techniques_cs":["Porovnání s etalonovým pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\ngaz, nadciśnienie od 0 Pa do 500 Pa CMC 0,2 Pa\ngaz, nadciśnienie od 0,5 kPa do 16 kPa CMC 0,027 %\ngaz, nadciśnienie od 7 MPa do 20 MPa CMC 0,005 %\ngaz, różnica ciśnień przy ciśnieniu statycznym (0,1 do 20,1) MPa od 0 kPa do 500 kPa CMC 0,014 %\nolej, nadciśnienie, ciśnienie bezwzględne od 0 kPa do 350 kPa CMC 0,042 kPa\nolej, nadciśnienie, ciśnienie bezwzględne od 350 kPa do 3 MPa CMC 0,009 %\nolej, nadciśnienie, ciśnienie bezwzględne od 3 MPa do 10 MPa CMC 0,46 kPa\nolej, nadciśnienie, ciśnienie bezwzględne od 10 MPa do 100 MPa CMC 0,005 %\nPorównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym","reference":"J62.03.P01, J62.03.P02, J62.03.P03","norm_bases":["J62.03.P01","J62.03.P02","J62.03.P03"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym gaz, nadciśnienie od 0 Pa do 500 Pa CMC 0,2 Pa gaz, nadciśnienie od 0,5 kPa do 16 kPa CMC 0,027 % gaz, nadciśnienie od 7 MPa do 20 MPa CMC 0,005 % gaz, różnica ciśnień przy ciśnieniu statycznym (0,1 do 20,1) MPa od 0 kPa do 500 kPa CMC 0,014 % olej, nadciśnienie, ciśnienie bezwzględne od 0 kPa do 350 kPa CMC 0,042 kPa olej, nadciśnienie, ciśnienie bezwzględne od 350 kPa do 3 MPa CMC 0,009 % olej, nadciśnienie, ciśnienie bezwzględne od 3 MPa do 10 MPa CMC 0,46 kPa olej, nadciśnienie, ciśnienie bezwzględne od 10 MPa do 100 MPa CMC 0,005 % Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku Kalibrace – tlak Porovnání s etalonovým pístovým tlakoměrem plyn, přetlak 0 Pa až 500 Pa CMC 0,2 Pa plyn, přetlak 0,5 kPa až 16 kPa CMC 0,027 % plyn, přetlak 7 MPa až 20 MPa CMC 0,005 % plyn, tlaková diference při stat. tlaku (0,1 až 20,1) MPa 0 kPa až 500 kPa CMC 0,014 % olej, přetlak, absolutní tlak 0 kPa až 350 kPa CMC 0,042 kPa olej, přetlak, absolutní tlak 350 kPa až 3 MPa CMC 0,009 % olej, přetlak, absolutní tlak 3 MPa až 10 MPa CMC 0,46 kPa olej, přetlak, absolutní tlak 10 MPa až 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia, w tym roznicowe, tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem obciaznikowo-tlokowym gaz, nadcisnienie od 0 Pa do 500 Pa CMC 0,2 Pa gaz, nadcisnienie od 0,5 kPa do 16 kPa CMC 0,027 % gaz, nadcisnienie od 7 MPa do 20 MPa CMC 0,005 % gaz, roznica cisnien przy cisnieniu statycznym (0,1 do 20,1) MPa od 0 kPa do 500 kPa CMC 0,014 % olej, nadcisnienie, cisnienie bezwzgledne od 0 kPa do 350 kPa CMC 0,042 kPa olej, nadcisnienie, cisnienie bezwzgledne od 350 kPa do 3 MPa CMC 0,009 % olej, nadcisnienie, cisnienie bezwzgledne od 3 MPa do 10 MPa CMC 0,46 kPa olej, nadcisnienie, cisnienie bezwzgledne od 10 MPa do 100 MPa CMC 0,005 % Deformacni a cislicove tlakomery, prevodniky tlaku vcetne diferencnich, merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym pistovym tlakomerem plyn, pretlak 0 Pa az 500 Pa CMC 0,2 Pa plyn, pretlak 0,5 kPa az 16 kPa CMC 0,027 % plyn, pretlak 7 MPa az 20 MPa CMC 0,005 % plyn, tlakova diference pri stat. tlaku (0,1 az 20,1) MPa 0 kPa az 500 kPa CMC 0,014 % olej, pretlak, absolutni tlak 0 kPa az 350 kPa CMC 0,042 kPa olej, pretlak, absolutni tlak 350 kPa az 3 MPa CMC 0,009 % olej, pretlak, absolutni tlak 3 MPa az 10 MPa CMC 0,46 kPa olej, pretlak, absolutni tlak 10 MPa az 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03","search_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains Calibration – pressure Comparison with a standard piston pressure gauge gas, gauge pressure 0 Pa to 500 Pa CMC 0,2 Pa gas, gauge pressure 0,5 kPa to 16 kPa CMC 0,027 % gas, gauge pressure 7 MPa to 20 MPa CMC 0,005 % gas, pressure difference at stat. pressure (0.1 to 20.1) MPa 0 kPa to 500 kPa CMC 0,014 % oil, gauge pressure, absolute pressure 0 kPa to 350 kPa CMC 0,042 kPa oil, gauge pressure, absolute pressure 350 kPa to 3 MPa CMC 0,009 % oil, gauge pressure, absolute pressure 3 MPa to 10 MPa CMC 0,46 kPa oil, gauge pressure, absolute pressure 10 MPa to 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03","search_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链 校准 – 压力 与标准活塞式压力计比较 气体，表压 0 Pa 至 500 Pa CMC 0,2 Pa 气体，表压 0,5 kPa 至 16 kPa CMC 0,027 % 气体，表压 7 MPa 至 20 MPa CMC 0,005 % 气体，静压 (0,1 至 20,1) MPa 下的压差 0 kPa 至 500 kPa CMC 0,014 % 油，表压、绝对压力 0 kPa 至 350 kPa CMC 0,042 kPa 油，表压、绝对压力 350 kPa 至 3 MPa CMC 0,009 % 油，表压、绝对压力 3 MPa 至 10 MPa CMC 0,46 kPa 油，表压、绝对压力 10 MPa 至 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7e5fa1392656ad1afd49f242","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia","test_object_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains","test_object_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链","test_object_cs":"Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku","methodology":"Wzorcowanie – ciśnienie","methodology_en":"Calibration – pressure","methodology_zh":"校准 – 压力","methodology_cs":"Kalibrace – tlak","parameters":[{"name":"gaz, nadciśnienie","range":"od 0 Pa do 500 Pa","cmc":"0,2 Pa"},{"name":"gaz, nadciśnienie","range":"od 0,5 kPa do 16 kPa","cmc":"0,027 %"},{"name":"gaz, nadciśnienie","range":"od 7 MPa do 20 MPa","cmc":"0,005 %"},{"name":"gaz, różnica ciśnień przy ciśnieniu statycznym (0,1 do 20,1) MPa","range":"od 0 kPa do 500 kPa","cmc":"0,014 %"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 0 kPa do 350 kPa","cmc":"0,042 kPa"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 350 kPa do 3 MPa","cmc":"0,009 %"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 3 MPa do 10 MPa","cmc":"0,46 kPa"},{"name":"olej, nadciśnienie, ciśnienie bezwzględne","range":"od 10 MPa do 100 MPa","cmc":"0,005 %"}],"parameters_en":[{"name":"gas, gauge pressure","range":"0 Pa to 500 Pa","cmc":"0,2 Pa"},{"name":"gas, gauge pressure","range":"0,5 kPa to 16 kPa","cmc":"0,027 %"},{"name":"gas, gauge pressure","range":"7 MPa to 20 MPa","cmc":"0,005 %"},{"name":"gas, pressure difference at stat. pressure (0.1 to 20.1) MPa","range":"0 kPa to 500 kPa","cmc":"0,014 %"},{"name":"oil, gauge pressure, absolute pressure","range":"0 kPa to 350 kPa","cmc":"0,042 kPa"},{"name":"oil, gauge pressure, absolute pressure","range":"350 kPa to 3 MPa","cmc":"0,009 %"},{"name":"oil, gauge pressure, absolute pressure","range":"3 MPa to 10 MPa","cmc":"0,46 kPa"},{"name":"oil, gauge pressure, absolute pressure","range":"10 MPa to 100 MPa","cmc":"0,005 %"}],"parameters_zh":[{"name":"气体，表压","range":"0 Pa 至 500 Pa","cmc":"0,2 Pa"},{"name":"气体，表压","range":"0,5 kPa 至 16 kPa","cmc":"0,027 %"},{"name":"气体，表压","range":"7 MPa 至 20 MPa","cmc":"0,005 %"},{"name":"气体，静压 (0,1 至 20,1) MPa 下的压差","range":"0 kPa 至 500 kPa","cmc":"0,014 %"},{"name":"油，表压、绝对压力","range":"0 kPa 至 350 kPa","cmc":"0,042 kPa"},{"name":"油，表压、绝对压力","range":"350 kPa 至 3 MPa","cmc":"0,009 %"},{"name":"油，表压、绝对压力","range":"3 MPa 至 10 MPa","cmc":"0,46 kPa"},{"name":"油，表压、绝对压力","range":"10 MPa 至 100 MPa","cmc":"0,005 %"}],"parameters_cs":[{"name":"plyn, přetlak","range":"0 Pa až 500 Pa","cmc":"0,2 Pa"},{"name":"plyn, přetlak","range":"0,5 kPa až 16 kPa","cmc":"0,027 %"},{"name":"plyn, přetlak","range":"7 MPa až 20 MPa","cmc":"0,005 %"},{"name":"plyn, tlaková diference při stat. tlaku (0,1 až 20,1) MPa","range":"0 kPa až 500 kPa","cmc":"0,014 %"},{"name":"olej, přetlak, absolutní tlak","range":"0 kPa až 350 kPa","cmc":"0,042 kPa"},{"name":"olej, přetlak, absolutní tlak","range":"350 kPa až 3 MPa","cmc":"0,009 %"},{"name":"olej, přetlak, absolutní tlak","range":"3 MPa až 10 MPa","cmc":"0,46 kPa"},{"name":"olej, přetlak, absolutní tlak","range":"10 MPa až 100 MPa","cmc":"0,005 %"}],"technique":"Porównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym","technique_en":"Comparison with a standard piston pressure gauge","technique_zh":"与标准活塞式压力计比较","technique_cs":"Porovnání s etalonovým pístovým tlakoměrem","techniques":["Porównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym"],"techniques_en":["Comparison with a standard piston pressure gauge"],"techniques_zh":["与标准活塞式压力计比较"],"techniques_cs":["Porovnání s etalonovým pístovým tlakoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – ciśnienie\nZakres:\ngaz, nadciśnienie od 0 Pa do 500 Pa CMC 0,2 Pa\ngaz, nadciśnienie od 0,5 kPa do 16 kPa CMC 0,027 %\ngaz, nadciśnienie od 7 MPa do 20 MPa CMC 0,005 %\ngaz, różnica ciśnień przy ciśnieniu statycznym (0,1 do 20,1) MPa od 0 kPa do 500 kPa CMC 0,014 %\nolej, nadciśnienie, ciśnienie bezwzględne od 0 kPa do 350 kPa CMC 0,042 kPa\nolej, nadciśnienie, ciśnienie bezwzględne od 350 kPa do 3 MPa CMC 0,009 %\nolej, nadciśnienie, ciśnienie bezwzględne od 3 MPa do 10 MPa CMC 0,46 kPa\nolej, nadciśnienie, ciśnienie bezwzględne od 10 MPa do 100 MPa CMC 0,005 %\nPorównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym","reference":"J62.03.P01, J62.03.P02, J62.03.P03","norm_bases":["J62.03.P01","J62.03.P02","J62.03.P03"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: ciśnienie","regulatory_area_en":"CMC for the field of measured quantity: Pressure","regulatory_area_zh":"被测量领域的CMC：压力","regulatory_area_cs":"CMC pro obor měřené veličiny: Tlak","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ciśnieniomierze sprężyste i cyfrowe, przetworniki ciśnienia, w tym różnicowe, tory pomiarowe ciśnienia Wzorcowanie – ciśnienie Porównanie z wzorcowym ciśnieniomierzem obciążnikowo-tłokowym gaz, nadciśnienie od 0 Pa do 500 Pa CMC 0,2 Pa gaz, nadciśnienie od 0,5 kPa do 16 kPa CMC 0,027 % gaz, nadciśnienie od 7 MPa do 20 MPa CMC 0,005 % gaz, różnica ciśnień przy ciśnieniu statycznym (0,1 do 20,1) MPa od 0 kPa do 500 kPa CMC 0,014 % olej, nadciśnienie, ciśnienie bezwzględne od 0 kPa do 350 kPa CMC 0,042 kPa olej, nadciśnienie, ciśnienie bezwzględne od 350 kPa do 3 MPa CMC 0,009 % olej, nadciśnienie, ciśnienie bezwzględne od 3 MPa do 10 MPa CMC 0,46 kPa olej, nadciśnienie, ciśnienie bezwzględne od 10 MPa do 100 MPa CMC 0,005 % Deformační a číslicové tlakoměry, převodníky tlaku včetně diferenčních, měřicí řetězce tlaku Kalibrace – tlak Porovnání s etalonovým pístovým tlakoměrem plyn, přetlak 0 Pa až 500 Pa CMC 0,2 Pa plyn, přetlak 0,5 kPa až 16 kPa CMC 0,027 % plyn, přetlak 7 MPa až 20 MPa CMC 0,005 % plyn, tlaková diference při stat. tlaku (0,1 až 20,1) MPa 0 kPa až 500 kPa CMC 0,014 % olej, přetlak, absolutní tlak 0 kPa až 350 kPa CMC 0,042 kPa olej, přetlak, absolutní tlak 350 kPa až 3 MPa CMC 0,009 % olej, přetlak, absolutní tlak 3 MPa až 10 MPa CMC 0,46 kPa olej, přetlak, absolutní tlak 10 MPa až 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03 Cisnieniomierze sprezyste i cyfrowe, przetworniki cisnienia, w tym roznicowe, tory pomiarowe cisnienia Wzorcowanie – cisnienie Porownanie z wzorcowym cisnieniomierzem obciaznikowo-tlokowym gaz, nadcisnienie od 0 Pa do 500 Pa CMC 0,2 Pa gaz, nadcisnienie od 0,5 kPa do 16 kPa CMC 0,027 % gaz, nadcisnienie od 7 MPa do 20 MPa CMC 0,005 % gaz, roznica cisnien przy cisnieniu statycznym (0,1 do 20,1) MPa od 0 kPa do 500 kPa CMC 0,014 % olej, nadcisnienie, cisnienie bezwzgledne od 0 kPa do 350 kPa CMC 0,042 kPa olej, nadcisnienie, cisnienie bezwzgledne od 350 kPa do 3 MPa CMC 0,009 % olej, nadcisnienie, cisnienie bezwzgledne od 3 MPa do 10 MPa CMC 0,46 kPa olej, nadcisnienie, cisnienie bezwzgledne od 10 MPa do 100 MPa CMC 0,005 % Deformacni a cislicove tlakomery, prevodniky tlaku vcetne diferencnich, merici retezce tlaku Kalibrace – tlak Porovnani s etalonovym pistovym tlakomerem plyn, pretlak 0 Pa az 500 Pa CMC 0,2 Pa plyn, pretlak 0,5 kPa az 16 kPa CMC 0,027 % plyn, pretlak 7 MPa az 20 MPa CMC 0,005 % plyn, tlakova diference pri stat. tlaku (0,1 az 20,1) MPa 0 kPa az 500 kPa CMC 0,014 % olej, pretlak, absolutni tlak 0 kPa az 350 kPa CMC 0,042 kPa olej, pretlak, absolutni tlak 350 kPa az 3 MPa CMC 0,009 % olej, pretlak, absolutni tlak 3 MPa az 10 MPa CMC 0,46 kPa olej, pretlak, absolutni tlak 10 MPa az 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03","search_en":"Deformation and digital manometers, pressure transducers including differential, pressure measuring chains Calibration – pressure Comparison with a standard piston pressure gauge gas, gauge pressure 0 Pa to 500 Pa CMC 0,2 Pa gas, gauge pressure 0,5 kPa to 16 kPa CMC 0,027 % gas, gauge pressure 7 MPa to 20 MPa CMC 0,005 % gas, pressure difference at stat. pressure (0.1 to 20.1) MPa 0 kPa to 500 kPa CMC 0,014 % oil, gauge pressure, absolute pressure 0 kPa to 350 kPa CMC 0,042 kPa oil, gauge pressure, absolute pressure 350 kPa to 3 MPa CMC 0,009 % oil, gauge pressure, absolute pressure 3 MPa to 10 MPa CMC 0,46 kPa oil, gauge pressure, absolute pressure 10 MPa to 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03","search_zh":"弹性式和数字式压力表、压力变送器（含差压变送器）、压力测量链 校准 – 压力 与标准活塞式压力计比较 气体，表压 0 Pa 至 500 Pa CMC 0,2 Pa 气体，表压 0,5 kPa 至 16 kPa CMC 0,027 % 气体，表压 7 MPa 至 20 MPa CMC 0,005 % 气体，静压 (0,1 至 20,1) MPa 下的压差 0 kPa 至 500 kPa CMC 0,014 % 油，表压、绝对压力 0 kPa 至 350 kPa CMC 0,042 kPa 油，表压、绝对压力 350 kPa 至 3 MPa CMC 0,009 % 油，表压、绝对压力 3 MPa 至 10 MPa CMC 0,46 kPa 油，表压、绝对压力 10 MPa 至 100 MPa CMC 0,005 % J62.03.P01, J62.03.P02, J62.03.P03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc4b2c9a4db6e891da33aa78","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Platynowe termometry rezystancyjne","test_object_en":"Platinum resistance thermometers","test_object_zh":"铂电阻温度计","test_object_cs":"Platinové odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_en":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_zh":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_cs":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"technique":"Pomiar bezpośredni w punkcie potrójnym wody","technique_en":"Direct measurement at triple point of water","technique_zh":"在水三相点直接测量","technique_cs":"Přímé měření v trojném bodě vody","techniques":["Pomiar bezpośredni w punkcie potrójnym wody"],"techniques_en":["Direct measurement at triple point of water"],"techniques_zh":["在水三相点直接测量"],"techniques_cs":["Přímé měření v trojném bodě vody"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0,01 °C CMC 0,004 °C\nPomiar bezpośredni w punkcie potrójnym wody","reference":"J 62.03.T04","norm_bases":["J 62.03.T04"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Platynowe termometry rezystancyjne Wzorcowanie – temperatura Pomiar bezpośredni w punkcie potrójnym wody 0,01 °C CMC 0,004 °C Platinové odporové teploměry Kalibrace – teplota Přímé měření v trojném bodě vody 0,01 °C CMC 0,004 °C J 62.03.T04 Platynowe termometry rezystancyjne Wzorcowanie – temperatura Pomiar bezposredni w punkcie potrojnym wody 0,01 °C CMC 0,004 °C Platinove odporove teplomery Kalibrace – teplota Prime mereni v trojnem bode vody 0,01 °C CMC 0,004 °C J 62.03.T04","search_en":"Platinum resistance thermometers Calibration – temperature Direct measurement at triple point of water 0,01 °C CMC 0,004 °C J 62.03.T04","search_zh":"铂电阻温度计 校准 – 温度 在水三相点直接测量 0,01 °C CMC 0,004 °C J 62.03.T04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73476145688a4011d3cd9f99","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Platynowe termometry rezystancyjne","test_object_en":"Platinum resistance thermometers","test_object_zh":"铂电阻温度计","test_object_cs":"Platinové odporové teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,010 °C"},{"name":"","range":"od 0 °C do 232 °C","cmc":"(1,3·10⁻⁵·t + 0,008) °C"},{"name":"","range":"od 232 °C do 420 °C","cmc":"(4,8·10⁻⁵·(t − 232) + 0,011) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,010 °C"},{"name":"","range":"0 °C to 232 °C","cmc":"(1,3·10⁻⁵·t + 0,008) °C"},{"name":"","range":"232 °C to 420 °C","cmc":"(4,8·10⁻⁵·(t − 232) + 0,011) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,010 °C"},{"name":"","range":"0 °C 至 232 °C","cmc":"(1,3·10⁻⁵·t + 0,008) °C"},{"name":"","range":"232 °C 至 420 °C","cmc":"(4,8·10⁻⁵·(t − 232) + 0,011) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,010 °C"},{"name":"","range":"0 °C až 232 °C","cmc":"(1,3·10⁻⁵·t + 0,008) °C"},{"name":"","range":"232 °C až 420 °C","cmc":"(4,8·10⁻⁵·(t − 232) + 0,011) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,010 °C\nod 0 °C do 232 °C CMC (1,3·10⁻⁵·t + 0,008) °C\nod 232 °C do 420 °C CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T04","norm_bases":["J 62.03.T04"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Platynowe termometry rezystancyjne Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,010 °C od 0 °C do 232 °C CMC (1,3·10⁻⁵·t + 0,008) °C od 232 °C do 420 °C CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C Platinové odporové teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,010 °C 0 °C až 232 °C CMC (1,3·10⁻⁵·t + 0,008) °C 232 °C až 420 °C CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C J 62.03.T04 Platynowe termometry rezystancyjne Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,010 °C od 0 °C do 232 °C CMC (1,3·10⁻⁵·t + 0,008) °C od 232 °C do 420 °C CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C Platinove odporove teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,010 °C 0 °C az 232 °C CMC (1,3·10⁻⁵·t + 0,008) °C 232 °C az 420 °C CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C J 62.03.T04","search_en":"Platinum resistance thermometers Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,010 °C 0 °C to 232 °C CMC (1,3·10⁻⁵·t + 0,008) °C 232 °C to 420 °C CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C J 62.03.T04","search_zh":"铂电阻温度计 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,010 °C 0 °C 至 232 °C CMC (1,3·10⁻⁵·t + 0,008) °C 232 °C 至 420 °C CMC (4,8·10⁻⁵·(t − 232) + 0,011) °C J 62.03.T04","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"388d4e32dcf1eaca297ac341","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"parameters_en":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"parameters_zh":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"parameters_cs":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"technique":"Pomiar bezpośredni w punkcie potrójnym wody","technique_en":"Direct measurement at triple point of water","technique_zh":"在水三相点直接测量","technique_cs":"Přímé měření v trojném bodě vody","techniques":["Pomiar bezpośredni w punkcie potrójnym wody"],"techniques_en":["Direct measurement at triple point of water"],"techniques_zh":["在水三相点直接测量"],"techniques_cs":["Přímé měření v trojném bodě vody"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0,01 °C CMC 0,01 °C\nPomiar bezpośredni w punkcie potrójnym wody","reference":"J 62.03.T01","norm_bases":["J 62.03.T01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":"Pomiar bezpośredni w punkcie potrójnym wody: nie dotyczy wzorcowań wykonywanych poza stałymi pomieszczeniami laboratorium.","note_en":"Direct measurement at triple point of water: Does not apply to calibrations performed outside the laboratory's permanent premises.","note_zh":"在水三相点直接测量：不适用于在实验室固定场所以外进行的校准。","note_cs":"Přímé měření v trojném bodě vody: Neplatí pro kalibrace prováděné mimo stálé prostory laboratoře.","search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Pomiar bezpośredni w punkcie potrójnym wody 0,01 °C CMC 0,01 °C Odporové snímače teploty Kalibrace – teplota Přímé měření v trojném bodě vody 0,01 °C CMC 0,01 °C J 62.03.T01 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Pomiar bezposredni w punkcie potrojnym wody 0,01 °C CMC 0,01 °C Odporove snimace teploty Kalibrace – teplota Prime mereni v trojnem bode vody 0,01 °C CMC 0,01 °C J 62.03.T01","search_en":"Resistance temperature sensors Calibration – temperature Direct measurement at triple point of water 0,01 °C CMC 0,01 °C J 62.03.T01","search_zh":"电阻式温度传感器 校准 – 温度 在水三相点直接测量 0,01 °C CMC 0,01 °C J 62.03.T01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d88b40f3609a53bd16f3088a","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"parameters_en":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"parameters_zh":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"parameters_cs":[{"name":"","range":"0,01 °C","cmc":"0,01 °C"}],"technique":"Pomiar bezpośredni w punkcie potrójnym wody","technique_en":"Direct measurement at triple point of water","technique_zh":"在水三相点直接测量","technique_cs":"Přímé měření v trojném bodě vody","techniques":["Pomiar bezpośredni w punkcie potrójnym wody"],"techniques_en":["Direct measurement at triple point of water"],"techniques_zh":["在水三相点直接测量"],"techniques_cs":["Přímé měření v trojném bodě vody"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0,01 °C CMC 0,01 °C\nPomiar bezpośredni w punkcie potrójnym wody","reference":"J 62.03.T01","norm_bases":["J 62.03.T01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":"Pomiar bezpośredni w punkcie potrójnym wody: nie dotyczy wzorcowań wykonywanych poza stałymi pomieszczeniami laboratorium.","note_en":"Direct measurement at triple point of water: Does not apply to calibrations performed outside the laboratory's permanent premises.","note_zh":"在水三相点直接测量：不适用于在实验室固定场所以外进行的校准。","note_cs":"Přímé měření v trojném bodě vody: Neplatí pro kalibrace prováděné mimo stálé prostory laboratoře.","search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Pomiar bezpośredni w punkcie potrójnym wody 0,01 °C CMC 0,01 °C Odporové snímače teploty Kalibrace – teplota Přímé měření v trojném bodě vody 0,01 °C CMC 0,01 °C J 62.03.T01 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Pomiar bezposredni w punkcie potrojnym wody 0,01 °C CMC 0,01 °C Odporove snimace teploty Kalibrace – teplota Prime mereni v trojnem bode vody 0,01 °C CMC 0,01 °C J 62.03.T01","search_en":"Resistance temperature sensors Calibration – temperature Direct measurement at triple point of water 0,01 °C CMC 0,01 °C J 62.03.T01","search_zh":"电阻式温度传感器 校准 – 温度 在水三相点直接测量 0,01 °C CMC 0,01 °C J 62.03.T01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e3df313f3781fbb52e701ef9","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,02 °C"},{"name":"","range":"od 0 °C do 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"od 232 °C do 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C to 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"232 °C to 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C 至 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"232 °C 至 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C až 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"232 °C až 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,02 °C\nod 0 °C do 232 °C CMC (5·10⁻⁵·t + 0,02) °C\nod 232 °C do 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C\nod 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T01","norm_bases":["J 62.03.T01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 232 °C CMC (5·10⁻⁵·t + 0,02) °C od 232 °C do 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,02 °C 0 °C až 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C až 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C až 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 232 °C CMC (5·10⁻⁵·t + 0,02) °C od 232 °C do 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,02 °C 0 °C az 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C az 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C az 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,02 °C 0 °C to 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C to 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C to 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01","search_zh":"电阻式温度传感器 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,02 °C 0 °C 至 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C 至 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C 至 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a08a15afa21dea796ebf9f1","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Rezystancyjne czujniki temperatury","test_object_en":"Resistance temperature sensors","test_object_zh":"电阻式温度传感器","test_object_cs":"Odporové snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,02 °C"},{"name":"","range":"od 0 °C do 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"od 232 °C do 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C to 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"232 °C to 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C 至 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"232 °C 至 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C až 232 °C","cmc":"(5·10⁻⁵·t + 0,02) °C"},{"name":"","range":"232 °C až 400 °C","cmc":"(5·10⁻⁵·(t − 232) + 0,032) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,02 °C\nod 0 °C do 232 °C CMC (5·10⁻⁵·t + 0,02) °C\nod 232 °C do 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C\nod 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T01","norm_bases":["J 62.03.T01"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 232 °C CMC (5·10⁻⁵·t + 0,02) °C od 232 °C do 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Odporové snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,02 °C 0 °C až 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C až 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C až 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01 Rezystancyjne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 232 °C CMC (5·10⁻⁵·t + 0,02) °C od 232 °C do 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Odporove snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,02 °C 0 °C az 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C az 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C az 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01","search_en":"Resistance temperature sensors Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,02 °C 0 °C to 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C to 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C to 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01","search_zh":"电阻式温度传感器 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,02 °C 0 °C 至 232 °C CMC (5·10⁻⁵·t + 0,02) °C 232 °C 至 400 °C CMC (5·10⁻⁵·(t − 232) + 0,032) °C 400 °C 至 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5ddb9320d4aa3d81d9b7079","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 100 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"","range":"−40 °C to 100 °C","cmc":"0,03 °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 100 °C","cmc":"0,03 °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 100 °C","cmc":"0,03 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod −40 °C do 100 °C CMC 0,03 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T03","norm_bases":["J 62.03.T03"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 100 °C CMC 0,03 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 100 °C CMC 0,03 °C J 62.03.T03 Termometry szklane Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 100 °C CMC 0,03 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 100 °C CMC 0,03 °C J 62.03.T03","search_en":"Glass thermometers Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 100 °C CMC 0,03 °C J 62.03.T03","search_zh":"玻璃温度计 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 100 °C CMC 0,03 °C J 62.03.T03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43c90be9060dd0d86a0e5411","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Termometry szklane","test_object_en":"Glass thermometers","test_object_zh":"玻璃温度计","test_object_cs":"Skleněné teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 100 °C","cmc":"0,03 °C"}],"parameters_en":[{"name":"","range":"−40 °C to 100 °C","cmc":"0,03 °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 100 °C","cmc":"0,03 °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 100 °C","cmc":"0,03 °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nod −40 °C do 100 °C CMC 0,03 °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T03","norm_bases":["J 62.03.T03"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry szklane Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 100 °C CMC 0,03 °C Skleněné teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 100 °C CMC 0,03 °C J 62.03.T03 Termometry szklane Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 100 °C CMC 0,03 °C Sklenene teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 100 °C CMC 0,03 °C J 62.03.T03","search_en":"Glass thermometers Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 100 °C CMC 0,03 °C J 62.03.T03","search_zh":"玻璃温度计 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 100 °C CMC 0,03 °C J 62.03.T03","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b78fd20a6631b5e6a95ffc34","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermocouple temperature sensors","test_object_zh":"热电偶温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,5 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,5 °C\nod 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C\nod 400 °C do 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T02","norm_bases":["J 62.03.T02"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,5 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C od 400 °C do 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,5 °C 0 °C až 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C až 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,5 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C od 400 °C do 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,5 °C 0 °C az 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C az 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02","search_en":"Thermocouple temperature sensors Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,5 °C 0 °C to 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C to 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02","search_zh":"热电偶温度传感器 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,5 °C 0 °C 至 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C 至 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3aacce32d64ee0f376daddfc","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Termoelektryczne czujniki temperatury","test_object_en":"Thermocouple temperature sensors","test_object_zh":"热电偶温度传感器","test_object_cs":"Termoelektrické snímače teploty","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,5 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,5 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(2,5·10⁻⁴·t + 0,4) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(2·10⁻³·(t − 400) + 0,5) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,5 °C\nod 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C\nod 400 °C do 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T02","norm_bases":["J 62.03.T02"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,5 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C od 400 °C do 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C Termoelektrické snímače teploty Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,5 °C 0 °C až 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C až 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02 Termoelektryczne czujniki temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,5 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C od 400 °C do 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C Termoelektricke snimace teploty Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,5 °C 0 °C az 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C az 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02","search_en":"Thermocouple temperature sensors Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,5 °C 0 °C to 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C to 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02","search_zh":"热电偶温度传感器 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,5 °C 0 °C 至 400 °C CMC (2,5·10⁻⁴·t + 0,4) °C 400 °C 至 550 °C CMC (2·10⁻³·(t − 400) + 0,5) °C J 62.03.T02","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a073885a5d1c62ea3bd6fbda","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Czujniki temperatury z przetwornikiem","test_object_en":"Temperature sensors with transducer","test_object_zh":"带变送器的温度传感器","test_object_cs":"Snímače teploty s převodníkem","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,03 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,03 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,03 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,03 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,03 °C\nod 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,03) °C\nod 400 °C do 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T06","norm_bases":["J 62.03.T06"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,03 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,03) °C od 400 °C do 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C Snímače teploty s převodníkem Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,03 °C 0 °C až 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C až 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06 Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,03 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,03) °C od 400 °C do 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C Snimace teploty s prevodnikem Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,03 °C 0 °C az 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C az 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06","search_en":"Temperature sensors with transducer Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,03 °C 0 °C to 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C to 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06","search_zh":"带变送器的温度传感器 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,03 °C 0 °C 至 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C 至 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4971ef2da868ea552c4cd4c8","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Czujniki temperatury z przetwornikiem","test_object_en":"Temperature sensors with transducer","test_object_zh":"带变送器的温度传感器","test_object_cs":"Snímače teploty s převodníkem","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,03 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,03 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,03 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,03 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(1·10⁻⁴·t + 0,03) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(4·10⁻⁴·(t − 400) + 0,07) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,03 °C\nod 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,03) °C\nod 400 °C do 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T06","norm_bases":["J 62.03.T06"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,03 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,03) °C od 400 °C do 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C Snímače teploty s převodníkem Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,03 °C 0 °C až 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C až 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06 Czujniki temperatury z przetwornikiem Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,03 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,03) °C od 400 °C do 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C Snimace teploty s prevodnikem Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,03 °C 0 °C az 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C az 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06","search_en":"Temperature sensors with transducer Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,03 °C 0 °C to 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C to 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06","search_zh":"带变送器的温度传感器 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,03 °C 0 °C 至 400 °C CMC (1·10⁻⁴·t + 0,03) °C 400 °C 至 550 °C CMC (4·10⁻⁴·(t − 400) + 0,07) °C J 62.03.T06","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cd7912ac1ab4b4e4be9b5ff8","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"6","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_en":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_zh":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_cs":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"technique":"Pomiar bezpośredni w punkcie potrójnym wody","technique_en":"Direct measurement at triple point of water","technique_zh":"在水三相点直接测量","technique_cs":"Přímé měření v trojném bodě vody","techniques":["Pomiar bezpośredni w punkcie potrójnym wody"],"techniques_en":["Direct measurement at triple point of water"],"techniques_zh":["在水三相点直接测量"],"techniques_cs":["Přímé měření v trojném bodě vody"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0,01 °C CMC 0,004 °C\nPomiar bezpośredni w punkcie potrójnym wody","reference":"J 62.03.T05","norm_bases":["J 62.03.T05"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":"Pomiar bezpośredni w punkcie potrójnym wody: nie dotyczy wzorcowań wykonywanych poza stałymi pomieszczeniami laboratorium.","note_en":"Direct measurement at triple point of water: Does not apply to calibrations performed outside the laboratory's permanent premises.","note_zh":"在水三相点直接测量：不适用于在实验室固定场所以外进行的校准。","note_cs":"Přímé měření v trojném bodě vody: Neplatí pro kalibrace prováděné mimo stálé prostory laboratoře.","search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Pomiar bezpośredni w punkcie potrójnym wody 0,01 °C CMC 0,004 °C Přímoukazující teploměry Kalibrace – teplota Přímé měření v trojném bodě vody 0,01 °C CMC 0,004 °C J 62.03.T05 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Pomiar bezposredni w punkcie potrojnym wody 0,01 °C CMC 0,004 °C Primoukazujici teplomery Kalibrace – teplota Prime mereni v trojnem bode vody 0,01 °C CMC 0,004 °C J 62.03.T05","search_en":"Direct-indicating thermometers Calibration – temperature Direct measurement at triple point of water 0,01 °C CMC 0,004 °C J 62.03.T05","search_zh":"直读式温度计 校准 – 温度 在水三相点直接测量 0,01 °C CMC 0,004 °C J 62.03.T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5d47e65cb3cf81cec7a76d3a","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"6","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_en":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_zh":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"parameters_cs":[{"name":"","range":"0,01 °C","cmc":"0,004 °C"}],"technique":"Pomiar bezpośredni w punkcie potrójnym wody","technique_en":"Direct measurement at triple point of water","technique_zh":"在水三相点直接测量","technique_cs":"Přímé měření v trojném bodě vody","techniques":["Pomiar bezpośredni w punkcie potrójnym wody"],"techniques_en":["Direct measurement at triple point of water"],"techniques_zh":["在水三相点直接测量"],"techniques_cs":["Přímé měření v trojném bodě vody"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\n0,01 °C CMC 0,004 °C\nPomiar bezpośredni w punkcie potrójnym wody","reference":"J 62.03.T05","norm_bases":["J 62.03.T05"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":false,"note":"Pomiar bezpośredni w punkcie potrójnym wody: nie dotyczy wzorcowań wykonywanych poza stałymi pomieszczeniami laboratorium.","note_en":"Direct measurement at triple point of water: Does not apply to calibrations performed outside the laboratory's permanent premises.","note_zh":"在水三相点直接测量：不适用于在实验室固定场所以外进行的校准。","note_cs":"Přímé měření v trojném bodě vody: Neplatí pro kalibrace prováděné mimo stálé prostory laboratoře.","search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Pomiar bezpośredni w punkcie potrójnym wody 0,01 °C CMC 0,004 °C Přímoukazující teploměry Kalibrace – teplota Přímé měření v trojném bodě vody 0,01 °C CMC 0,004 °C J 62.03.T05 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Pomiar bezposredni w punkcie potrojnym wody 0,01 °C CMC 0,004 °C Primoukazujici teplomery Kalibrace – teplota Prime mereni v trojnem bode vody 0,01 °C CMC 0,004 °C J 62.03.T05","search_en":"Direct-indicating thermometers Calibration – temperature Direct measurement at triple point of water 0,01 °C CMC 0,004 °C J 62.03.T05","search_zh":"直读式温度计 校准 – 温度 在水三相点直接测量 0,01 °C CMC 0,004 °C J 62.03.T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f56708443c1ab333ecc1e7c","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"6","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,02 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,02 °C\nod 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,02) °C\nod 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T05","norm_bases":["J 62.03.T05"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,02) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,02 °C 0 °C až 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C až 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,02) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,02 °C 0 °C az 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C az 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,02 °C 0 °C to 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C to 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05","search_zh":"直读式温度计 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,02 °C 0 °C 至 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C 至 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e7bb8e2b63b2e8957f3b8441","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"6","test_object":"Termometry bezpośrednio wskazujące","test_object_en":"Direct-indicating thermometers","test_object_zh":"直读式温度计","test_object_cs":"Přímoukazující teploměry","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −40 °C do 0 °C","cmc":"0,02 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"od 400 °C do 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_en":[{"name":"","range":"−40 °C to 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"400 °C to 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_zh":[{"name":"","range":"−40 °C 至 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"400 °C 至 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"parameters_cs":[{"name":"","range":"−40 °C až 0 °C","cmc":"0,02 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(1·10⁻⁴·t + 0,02) °C"},{"name":"","range":"400 °C až 550 °C","cmc":"(2·10⁻⁴·(t − 400) + 0,06) °C"}],"technique":"Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","technique_en":"Comparison with a reference resistance thermometer in a liquid bath","technique_zh":"在液体槽中与标准电阻温度计比较","technique_cs":"Porovnání s etalonovým odporovým teploměrem v kapalinové lázni","techniques":["Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej"],"techniques_en":["Comparison with a reference resistance thermometer in a liquid bath"],"techniques_zh":["在液体槽中与标准电阻温度计比较"],"techniques_cs":["Porovnání s etalonovým odporovým teploměrem v kapalinové lázni"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −40 °C do 0 °C CMC 0,02 °C\nod 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,02) °C\nod 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C\nPorównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej","reference":"J 62.03.T05","norm_bases":["J 62.03.T05"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Termometry bezpośrednio wskazujące Wzorcowanie – temperatura Porównanie z wzorcowym termometrem rezystancyjnym w łaźni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,02) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Přímoukazující teploměry Kalibrace – teplota Porovnání s etalonovým odporovým teploměrem v kapalinové lázni −40 °C až 0 °C CMC 0,02 °C 0 °C až 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C až 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05 Termometry bezposrednio wskazujace Wzorcowanie – temperatura Porownanie z wzorcowym termometrem rezystancyjnym w lazni cieczowej od −40 °C do 0 °C CMC 0,02 °C od 0 °C do 400 °C CMC (1·10⁻⁴·t + 0,02) °C od 400 °C do 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C Primoukazujici teplomery Kalibrace – teplota Porovnani s etalonovym odporovym teplomerem v kapalinove lazni −40 °C az 0 °C CMC 0,02 °C 0 °C az 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C az 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05","search_en":"Direct-indicating thermometers Calibration – temperature Comparison with a reference resistance thermometer in a liquid bath −40 °C to 0 °C CMC 0,02 °C 0 °C to 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C to 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05","search_zh":"直读式温度计 校准 – 温度 在液体槽中与标准电阻温度计比较 −40 °C 至 0 °C CMC 0,02 °C 0 °C 至 400 °C CMC (1·10⁻⁴·t + 0,02) °C 400 °C 至 550 °C CMC (2·10⁻⁴·(t − 400) + 0,06) °C J 62.03.T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f5c7e0c2cf7508ac2ee5914c","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"7","test_object":"Tory pomiarowe temperatury wraz z czujnikami temperatury","test_object_en":"Temperature measuring chains, including thermal sensors","test_object_zh":"温度测量链（含温度传感器）","test_object_cs":"Měřicí řetězce teploty včetně teplotních čidel","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −30 °C do 0 °C","cmc":"0,1 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"od 400 °C do 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"parameters_en":[{"name":"","range":"−30 °C to 0 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"400 °C to 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"parameters_zh":[{"name":"","range":"−30 °C 至 0 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"400 °C 至 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"parameters_cs":[{"name":"","range":"−30 °C až 0 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"400 °C až 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"technique":"Porównanie z wzorcowym termometrem elektronicznym w piecu pionowym","technique_en":"Comparison with a reference electronic thermometer in a vertical furnace","technique_zh":"在立式炉中与标准电子温度计比较","technique_cs":"Porovnání s etalonovým elektronickým teploměrem ve vertikální peci","techniques":["Porównanie z wzorcowym termometrem elektronicznym w piecu pionowym"],"techniques_en":["Comparison with a reference electronic thermometer in a vertical furnace"],"techniques_zh":["在立式炉中与标准电子温度计比较"],"techniques_cs":["Porovnání s etalonovým elektronickým teploměrem ve vertikální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −30 °C do 0 °C CMC 0,1 °C\nod 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C\nod 400 °C do 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C\nPorównanie z wzorcowym termometrem elektronicznym w piecu pionowym","reference":"J 62.03.T05","norm_bases":["J 62.03.T05"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe temperatury wraz z czujnikami temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem elektronicznym w piecu pionowym od −30 °C do 0 °C CMC 0,1 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C od 400 °C do 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C Měřicí řetězce teploty včetně teplotních čidel Kalibrace – teplota Porovnání s etalonovým elektronickým teploměrem ve vertikální peci −30 °C až 0 °C CMC 0,1 °C 0 °C až 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C až 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05 Tory pomiarowe temperatury wraz z czujnikami temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem elektronicznym w piecu pionowym od −30 °C do 0 °C CMC 0,1 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C od 400 °C do 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C Merici retezce teploty vcetne teplotnich cidel Kalibrace – teplota Porovnani s etalonovym elektronickym teplomerem ve vertikalni peci −30 °C az 0 °C CMC 0,1 °C 0 °C az 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C az 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05","search_en":"Temperature measuring chains, including thermal sensors Calibration – temperature Comparison with a reference electronic thermometer in a vertical furnace −30 °C to 0 °C CMC 0,1 °C 0 °C to 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C to 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05","search_zh":"温度测量链（含温度传感器） 校准 – 温度 在立式炉中与标准电子温度计比较 −30 °C 至 0 °C CMC 0,1 °C 0 °C 至 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C 至 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"971faccb27f0248caca69fa0","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"7","test_object":"Tory pomiarowe temperatury wraz z czujnikami temperatury","test_object_en":"Temperature measuring chains, including thermal sensors","test_object_zh":"温度测量链（含温度传感器）","test_object_cs":"Měřicí řetězce teploty včetně teplotních čidel","methodology":"Wzorcowanie – temperatura","methodology_en":"Calibration – temperature","methodology_zh":"校准 – 温度","methodology_cs":"Kalibrace – teplota","parameters":[{"name":"","range":"od −30 °C do 0 °C","cmc":"0,1 °C"},{"name":"","range":"od 0 °C do 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"od 400 °C do 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"parameters_en":[{"name":"","range":"−30 °C to 0 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C to 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"400 °C to 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"parameters_zh":[{"name":"","range":"−30 °C 至 0 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C 至 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"400 °C 至 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"parameters_cs":[{"name":"","range":"−30 °C až 0 °C","cmc":"0,1 °C"},{"name":"","range":"0 °C až 400 °C","cmc":"(2,5·10⁻⁴·t + 0,1) °C"},{"name":"","range":"400 °C až 660 °C","cmc":"1,5·10⁻³·(t − 400) + 0,2) °C"}],"technique":"Porównanie z wzorcowym termometrem elektronicznym w piecu pionowym","technique_en":"Comparison with a reference electronic thermometer in a vertical furnace","technique_zh":"在立式炉中与标准电子温度计比较","technique_cs":"Porovnání s etalonovým elektronickým teploměrem ve vertikální peci","techniques":["Porównanie z wzorcowym termometrem elektronicznym w piecu pionowym"],"techniques_en":["Comparison with a reference electronic thermometer in a vertical furnace"],"techniques_zh":["在立式炉中与标准电子温度计比较"],"techniques_cs":["Porovnání s etalonovým elektronickým teploměrem ve vertikální peci"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – temperatura\nZakres:\nod −30 °C do 0 °C CMC 0,1 °C\nod 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C\nod 400 °C do 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C\nPorównanie z wzorcowym termometrem elektronicznym w piecu pionowym","reference":"J 62.03.T05","norm_bases":["J 62.03.T05"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: temperatura","regulatory_area_en":"CMC for the field of measured quantity: Temperature","regulatory_area_zh":"被测量领域的CMC：温度","regulatory_area_cs":"CMC pro obor měřené veličiny: Teplota","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Tory pomiarowe temperatury wraz z czujnikami temperatury Wzorcowanie – temperatura Porównanie z wzorcowym termometrem elektronicznym w piecu pionowym od −30 °C do 0 °C CMC 0,1 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C od 400 °C do 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C Měřicí řetězce teploty včetně teplotních čidel Kalibrace – teplota Porovnání s etalonovým elektronickým teploměrem ve vertikální peci −30 °C až 0 °C CMC 0,1 °C 0 °C až 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C až 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05 Tory pomiarowe temperatury wraz z czujnikami temperatury Wzorcowanie – temperatura Porownanie z wzorcowym termometrem elektronicznym w piecu pionowym od −30 °C do 0 °C CMC 0,1 °C od 0 °C do 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C od 400 °C do 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C Merici retezce teploty vcetne teplotnich cidel Kalibrace – teplota Porovnani s etalonovym elektronickym teplomerem ve vertikalni peci −30 °C az 0 °C CMC 0,1 °C 0 °C az 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C az 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05","search_en":"Temperature measuring chains, including thermal sensors Calibration – temperature Comparison with a reference electronic thermometer in a vertical furnace −30 °C to 0 °C CMC 0,1 °C 0 °C to 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C to 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05","search_zh":"温度测量链（含温度传感器） 校准 – 温度 在立式炉中与标准电子温度计比较 −30 °C 至 0 °C CMC 0,1 °C 0 °C 至 400 °C CMC (2,5·10⁻⁴·t + 0,1) °C 400 °C 至 660 °C CMC 1,5·10⁻³·(t − 400) + 0,2) °C J 62.03.T05","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6f7ddb77025b7ddcb8d925a4","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Higrometry analogowe i cyfrowe, przetworniki wilgotności i tory pomiarowe wilgotności wraz z sondami wilgotności","test_object_en":"Analogue and digital hygrometers, humidity transducers and humidity measuring chains, including humidity probes","test_object_zh":"模拟和数字湿度计、湿度变送器及湿度测量链（含湿度探头）","test_object_cs":"Analogové a digitální vlhkoměry, převodníky vlhkosti a měřicí řetězce vlhkosti včetně vlhkostních sond","methodology":"Wzorcowanie – wilgotność powietrza","methodology_en":"Calibration – air humidity","methodology_zh":"校准 – 空气湿度","methodology_cs":"Kalibrace – vlhkost vzduchu","parameters":[{"name":"(15 do 35) °C","range":"od 10 % RH do 70 % RH","cmc":"2,0 % RH"},{"name":"(15 do 35) °C","range":"od 70 % RH do 90 % RH","cmc":"2,3 % RH"}],"parameters_en":[{"name":"(15 to 35) °C","range":"10 % RH to 70 % RH","cmc":"2,0 % RH"},{"name":"(15 to 35) °C","range":"70 % RH to 90 % RH","cmc":"2,3 % RH"}],"parameters_zh":[{"name":"(15 至 35) °C","range":"10 % RH 至 70 % RH","cmc":"2,0 % RH"},{"name":"(15 至 35) °C","range":"70 % RH 至 90 % RH","cmc":"2,3 % RH"}],"parameters_cs":[{"name":"(15 až 35) °C","range":"10 % RH až 70 % RH","cmc":"2,0 % RH"},{"name":"(15 až 35) °C","range":"70 % RH až 90 % RH","cmc":"2,3 % RH"}],"technique":"Porównanie z wzorcowym przetwornikiem wilgotności w komorze klimatycznej","technique_en":"Comparison with a reference humidity transducer in a climatic chamber","technique_zh":"在气候箱中与标准湿度变送器比较","technique_cs":"Porovnání s etalonovým převodníkem vlhkosti v klimatické komoře","techniques":["Porównanie z wzorcowym przetwornikiem wilgotności w komorze klimatycznej"],"techniques_en":["Comparison with a reference humidity transducer in a climatic chamber"],"techniques_zh":["在气候箱中与标准湿度变送器比较"],"techniques_cs":["Porovnání s etalonovým převodníkem vlhkosti v klimatické komoře"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wilgotność powietrza\nZakres:\n(15 do 35) °C od 10 % RH do 70 % RH CMC 2,0 % RH\n(15 do 35) °C od 70 % RH do 90 % RH CMC 2,3 % RH\nPorównanie z wzorcowym przetwornikiem wilgotności w komorze klimatycznej","reference":"J 62.03.M01","norm_bases":["J 62.03.M01"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wilgotność powietrza","regulatory_area_en":"CMC for the field of measured quantity: Air humidity","regulatory_area_zh":"被测量领域的CMC：空气湿度","regulatory_area_cs":"CMC pro obor měřené veličiny: Vlhkost vzduchu","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Higrometry analogowe i cyfrowe, przetworniki wilgotności i tory pomiarowe wilgotności wraz z sondami wilgotności Wzorcowanie – wilgotność powietrza Porównanie z wzorcowym przetwornikiem wilgotności w komorze klimatycznej (15 do 35) °C od 10 % RH do 70 % RH CMC 2,0 % RH (15 do 35) °C od 70 % RH do 90 % RH CMC 2,3 % RH Analogové a digitální vlhkoměry, převodníky vlhkosti a měřicí řetězce vlhkosti včetně vlhkostních sond Kalibrace – vlhkost vzduchu Porovnání s etalonovým převodníkem vlhkosti v klimatické komoře (15 až 35) °C 10 % RH až 70 % RH CMC 2,0 % RH (15 až 35) °C 70 % RH až 90 % RH CMC 2,3 % RH J 62.03.M01 Higrometry analogowe i cyfrowe, przetworniki wilgotnosci i tory pomiarowe wilgotnosci wraz z sondami wilgotnosci Wzorcowanie – wilgotnosc powietrza Porownanie z wzorcowym przetwornikiem wilgotnosci w komorze klimatycznej (15 do 35) °C od 10 % RH do 70 % RH CMC 2,0 % RH (15 do 35) °C od 70 % RH do 90 % RH CMC 2,3 % RH Analogove a digitalni vlhkomery, prevodniky vlhkosti a merici retezce vlhkosti vcetne vlhkostnich sond Kalibrace – vlhkost vzduchu Porovnani s etalonovym prevodnikem vlhkosti v klimaticke komore (15 az 35) °C 10 % RH az 70 % RH CMC 2,0 % RH (15 az 35) °C 70 % RH az 90 % RH CMC 2,3 % RH J 62.03.M01","search_en":"Analogue and digital hygrometers, humidity transducers and humidity measuring chains, including humidity probes Calibration – air humidity Comparison with a reference humidity transducer in a climatic chamber (15 to 35) °C 10 % RH to 70 % RH CMC 2,0 % RH (15 to 35) °C 70 % RH to 90 % RH CMC 2,3 % RH J 62.03.M01","search_zh":"模拟和数字湿度计、湿度变送器及湿度测量链（含湿度探头） 校准 – 空气湿度 在气候箱中与标准湿度变送器比较 (15 至 35) °C 10 % RH 至 70 % RH CMC 2,0 % RH (15 至 35) °C 70 % RH 至 90 % RH CMC 2,3 % RH J 62.03.M01","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1bcd1b5d21fe45fc9532cb1e","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego","test_object_en":"DC voltage / DC voltage meters and generators","test_object_zh":"直流电压 / 直流电压测量仪器和发生器","test_object_cs":"Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"od 220 mV do 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"od 2,2 V do 11 V","cmc":"4,9 µV/V"},{"name":"","range":"od 11 V do 22 V","cmc":"4,7 µV/V"},{"name":"","range":"od 22 V do 220 V","cmc":"6,4 µV/V"},{"name":"","range":"od 220 V do 1100 V","cmc":"8,5 µV/V"}],"parameters_en":[{"name":"","range":"0 mV to 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"220 mV to 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"2,2 V to 11 V","cmc":"4,9 µV/V"},{"name":"","range":"11 V to 22 V","cmc":"4,7 µV/V"},{"name":"","range":"22 V to 220 V","cmc":"6,4 µV/V"},{"name":"","range":"220 V to 1100 V","cmc":"8,5 µV/V"}],"parameters_zh":[{"name":"","range":"0 mV 至 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"220 mV 至 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"2,2 V 至 11 V","cmc":"4,9 µV/V"},{"name":"","range":"11 V 至 22 V","cmc":"4,7 µV/V"},{"name":"","range":"22 V 至 220 V","cmc":"6,4 µV/V"},{"name":"","range":"220 V 至 1100 V","cmc":"8,5 µV/V"}],"parameters_cs":[{"name":"","range":"0 mV až 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"220 mV až 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"2,2 V až 11 V","cmc":"4,9 µV/V"},{"name":"","range":"11 V až 22 V","cmc":"4,7 µV/V"},{"name":"","range":"22 V až 220 V","cmc":"6,4 µV/V"},{"name":"","range":"220 V až 1100 V","cmc":"8,5 µV/V"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 220 mV CMC 11 µV/V + 0,4 µV\nod 220 mV do 2,2 V CMC 6,4 µV/V\nod 2,2 V do 11 V CMC 4,9 µV/V\nod 11 V do 22 V CMC 4,7 µV/V\nod 22 V do 220 V CMC 6,4 µV/V\nod 220 V do 1100 V CMC 8,5 µV/V\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","norm_bases":["J 62.03.E01.0","J 62.03.E08.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 mV do 220 mV CMC 11 µV/V + 0,4 µV od 220 mV do 2,2 V CMC 6,4 µV/V od 2,2 V do 11 V CMC 4,9 µV/V od 11 V do 22 V CMC 4,7 µV/V od 22 V do 220 V CMC 6,4 µV/V od 220 V do 1100 V CMC 8,5 µV/V Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 mV až 220 mV CMC 11 µV/V + 0,4 µV 220 mV až 2,2 V CMC 6,4 µV/V 2,2 V až 11 V CMC 4,9 µV/V 11 V až 22 V CMC 4,7 µV/V 22 V až 220 V CMC 6,4 µV/V 220 V až 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 Napiecie stale / przyrzady do pomiaru i generatory napiecia stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 mV do 220 mV CMC 11 µV/V + 0,4 µV od 220 mV do 2,2 V CMC 6,4 µV/V od 2,2 V do 11 V CMC 4,9 µV/V od 11 V do 22 V CMC 4,7 µV/V od 22 V do 220 V CMC 6,4 µV/V od 220 V do 1100 V CMC 8,5 µV/V Stejnosmerne napeti / meridla a generatory stejnosmerneho napeti Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 mV az 220 mV CMC 11 µV/V + 0,4 µV 220 mV az 2,2 V CMC 6,4 µV/V 2,2 V az 11 V CMC 4,9 µV/V 11 V az 22 V CMC 4,7 µV/V 22 V az 220 V CMC 6,4 µV/V 220 V az 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_en":"DC voltage / DC voltage meters and generators Calibration – electrical quantities Direct generation with a calibrator 0 mV to 220 mV CMC 11 µV/V + 0,4 µV 220 mV to 2,2 V CMC 6,4 µV/V 2,2 V to 11 V CMC 4,9 µV/V 11 V to 22 V CMC 4,7 µV/V 22 V to 220 V CMC 6,4 µV/V 220 V to 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_zh":"直流电压 / 直流电压测量仪器和发生器 校准 – 电学量 用校准器直接产生 0 mV 至 220 mV CMC 11 µV/V + 0,4 µV 220 mV 至 2,2 V CMC 6,4 µV/V 2,2 V 至 11 V CMC 4,9 µV/V 11 V 至 22 V CMC 4,7 µV/V 22 V 至 220 V CMC 6,4 µV/V 220 V 至 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f0e440711e17ccfdd545a07e","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego","test_object_en":"DC voltage / DC voltage meters and generators","test_object_zh":"直流电压 / 直流电压测量仪器和发生器","test_object_cs":"Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"od 220 mV do 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"od 2,2 V do 11 V","cmc":"4,9 µV/V"},{"name":"","range":"od 11 V do 22 V","cmc":"4,7 µV/V"},{"name":"","range":"od 22 V do 220 V","cmc":"6,4 µV/V"},{"name":"","range":"od 220 V do 1100 V","cmc":"8,5 µV/V"}],"parameters_en":[{"name":"","range":"0 mV to 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"220 mV to 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"2,2 V to 11 V","cmc":"4,9 µV/V"},{"name":"","range":"11 V to 22 V","cmc":"4,7 µV/V"},{"name":"","range":"22 V to 220 V","cmc":"6,4 µV/V"},{"name":"","range":"220 V to 1100 V","cmc":"8,5 µV/V"}],"parameters_zh":[{"name":"","range":"0 mV 至 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"220 mV 至 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"2,2 V 至 11 V","cmc":"4,9 µV/V"},{"name":"","range":"11 V 至 22 V","cmc":"4,7 µV/V"},{"name":"","range":"22 V 至 220 V","cmc":"6,4 µV/V"},{"name":"","range":"220 V 至 1100 V","cmc":"8,5 µV/V"}],"parameters_cs":[{"name":"","range":"0 mV až 220 mV","cmc":"11 µV/V + 0,4 µV"},{"name":"","range":"220 mV až 2,2 V","cmc":"6,4 µV/V"},{"name":"","range":"2,2 V až 11 V","cmc":"4,9 µV/V"},{"name":"","range":"11 V až 22 V","cmc":"4,7 µV/V"},{"name":"","range":"22 V až 220 V","cmc":"6,4 µV/V"},{"name":"","range":"220 V až 1100 V","cmc":"8,5 µV/V"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 220 mV CMC 11 µV/V + 0,4 µV\nod 220 mV do 2,2 V CMC 6,4 µV/V\nod 2,2 V do 11 V CMC 4,9 µV/V\nod 11 V do 22 V CMC 4,7 µV/V\nod 22 V do 220 V CMC 6,4 µV/V\nod 220 V do 1100 V CMC 8,5 µV/V\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","norm_bases":["J 62.03.E01.0","J 62.03.E08.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 mV do 220 mV CMC 11 µV/V + 0,4 µV od 220 mV do 2,2 V CMC 6,4 µV/V od 2,2 V do 11 V CMC 4,9 µV/V od 11 V do 22 V CMC 4,7 µV/V od 22 V do 220 V CMC 6,4 µV/V od 220 V do 1100 V CMC 8,5 µV/V Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 mV až 220 mV CMC 11 µV/V + 0,4 µV 220 mV až 2,2 V CMC 6,4 µV/V 2,2 V až 11 V CMC 4,9 µV/V 11 V až 22 V CMC 4,7 µV/V 22 V až 220 V CMC 6,4 µV/V 220 V až 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 Napiecie stale / przyrzady do pomiaru i generatory napiecia stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 mV do 220 mV CMC 11 µV/V + 0,4 µV od 220 mV do 2,2 V CMC 6,4 µV/V od 2,2 V do 11 V CMC 4,9 µV/V od 11 V do 22 V CMC 4,7 µV/V od 22 V do 220 V CMC 6,4 µV/V od 220 V do 1100 V CMC 8,5 µV/V Stejnosmerne napeti / meridla a generatory stejnosmerneho napeti Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 mV az 220 mV CMC 11 µV/V + 0,4 µV 220 mV az 2,2 V CMC 6,4 µV/V 2,2 V az 11 V CMC 4,9 µV/V 11 V az 22 V CMC 4,7 µV/V 22 V az 220 V CMC 6,4 µV/V 220 V az 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_en":"DC voltage / DC voltage meters and generators Calibration – electrical quantities Direct generation with a calibrator 0 mV to 220 mV CMC 11 µV/V + 0,4 µV 220 mV to 2,2 V CMC 6,4 µV/V 2,2 V to 11 V CMC 4,9 µV/V 11 V to 22 V CMC 4,7 µV/V 22 V to 220 V CMC 6,4 µV/V 220 V to 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_zh":"直流电压 / 直流电压测量仪器和发生器 校准 – 电学量 用校准器直接产生 0 mV 至 220 mV CMC 11 µV/V + 0,4 µV 220 mV 至 2,2 V CMC 6,4 µV/V 2,2 V 至 11 V CMC 4,9 µV/V 11 V 至 22 V CMC 4,7 µV/V 22 V 至 220 V CMC 6,4 µV/V 220 V 至 1100 V CMC 8,5 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2f0e52847fa479e1af69f4bd","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego","test_object_en":"DC voltage / DC voltage meters and generators","test_object_zh":"直流电压 / 直流电压测量仪器和发生器","test_object_cs":"Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"od 100 mV do 1 V","cmc":"6,2 µV/V"},{"name":"","range":"od 1 V do 10 V","cmc":"5,4 µV/V"},{"name":"","range":"od 10 V do 1000 V","cmc":"8,2 µV/V"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"100 mV to 1 V","cmc":"6,2 µV/V"},{"name":"","range":"1 V to 10 V","cmc":"5,4 µV/V"},{"name":"","range":"10 V to 1000 V","cmc":"8,2 µV/V"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"100 mV 至 1 V","cmc":"6,2 µV/V"},{"name":"","range":"1 V 至 10 V","cmc":"5,4 µV/V"},{"name":"","range":"10 V 至 1000 V","cmc":"8,2 µV/V"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"100 mV až 1 V","cmc":"6,2 µV/V"},{"name":"","range":"1 V až 10 V","cmc":"5,4 µV/V"},{"name":"","range":"10 V až 1000 V","cmc":"8,2 µV/V"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 9 µV/V + 0,3 µV\nod 100 mV do 1 V CMC 6,2 µV/V\nod 1 V do 10 V CMC 5,4 µV/V\nod 10 V do 1000 V CMC 8,2 µV/V\nPomiar bezpośredni multimetrem","reference":"J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","norm_bases":["J 62.03.E01.0","J 62.03.E08.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 mV do 100 mV CMC 9 µV/V + 0,3 µV od 100 mV do 1 V CMC 6,2 µV/V od 1 V do 10 V CMC 5,4 µV/V od 10 V do 1000 V CMC 8,2 µV/V Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 0 mV až 100 mV CMC 9 µV/V + 0,3 µV 100 mV až 1 V CMC 6,2 µV/V 1 V až 10 V CMC 5,4 µV/V 10 V až 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 Napiecie stale / przyrzady do pomiaru i generatory napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 mV do 100 mV CMC 9 µV/V + 0,3 µV od 100 mV do 1 V CMC 6,2 µV/V od 1 V do 10 V CMC 5,4 µV/V od 10 V do 1000 V CMC 8,2 µV/V Stejnosmerne napeti / meridla a generatory stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 0 mV az 100 mV CMC 9 µV/V + 0,3 µV 100 mV az 1 V CMC 6,2 µV/V 1 V az 10 V CMC 5,4 µV/V 10 V az 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_en":"DC voltage / DC voltage meters and generators Calibration – electrical quantities Direct measurement using a multimeter 0 mV to 100 mV CMC 9 µV/V + 0,3 µV 100 mV to 1 V CMC 6,2 µV/V 1 V to 10 V CMC 5,4 µV/V 10 V to 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_zh":"直流电压 / 直流电压测量仪器和发生器 校准 – 电学量 用万用表直接测量 0 mV 至 100 mV CMC 9 µV/V + 0,3 µV 100 mV 至 1 V CMC 6,2 µV/V 1 V 至 10 V CMC 5,4 µV/V 10 V 至 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d35d1886c6f8e53814beda83","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego","test_object_en":"DC voltage / DC voltage meters and generators","test_object_zh":"直流电压 / 直流电压测量仪器和发生器","test_object_cs":"Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"od 100 mV do 1 V","cmc":"6,2 µV/V"},{"name":"","range":"od 1 V do 10 V","cmc":"5,4 µV/V"},{"name":"","range":"od 10 V do 1000 V","cmc":"8,2 µV/V"}],"parameters_en":[{"name":"","range":"0 mV to 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"100 mV to 1 V","cmc":"6,2 µV/V"},{"name":"","range":"1 V to 10 V","cmc":"5,4 µV/V"},{"name":"","range":"10 V to 1000 V","cmc":"8,2 µV/V"}],"parameters_zh":[{"name":"","range":"0 mV 至 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"100 mV 至 1 V","cmc":"6,2 µV/V"},{"name":"","range":"1 V 至 10 V","cmc":"5,4 µV/V"},{"name":"","range":"10 V 至 1000 V","cmc":"8,2 µV/V"}],"parameters_cs":[{"name":"","range":"0 mV až 100 mV","cmc":"9 µV/V + 0,3 µV"},{"name":"","range":"100 mV až 1 V","cmc":"6,2 µV/V"},{"name":"","range":"1 V až 10 V","cmc":"5,4 µV/V"},{"name":"","range":"10 V až 1000 V","cmc":"8,2 µV/V"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 100 mV CMC 9 µV/V + 0,3 µV\nod 100 mV do 1 V CMC 6,2 µV/V\nod 1 V do 10 V CMC 5,4 µV/V\nod 10 V do 1000 V CMC 8,2 µV/V\nPomiar bezpośredni multimetrem","reference":"J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","norm_bases":["J 62.03.E01.0","J 62.03.E08.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / przyrządy do pomiaru i generatory napięcia stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 mV do 100 mV CMC 9 µV/V + 0,3 µV od 100 mV do 1 V CMC 6,2 µV/V od 1 V do 10 V CMC 5,4 µV/V od 10 V do 1000 V CMC 8,2 µV/V Stejnosměrné napětí / měřidla a generátory stejnosměrného napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 0 mV až 100 mV CMC 9 µV/V + 0,3 µV 100 mV až 1 V CMC 6,2 µV/V 1 V až 10 V CMC 5,4 µV/V 10 V až 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0 Napiecie stale / przyrzady do pomiaru i generatory napiecia stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 mV do 100 mV CMC 9 µV/V + 0,3 µV od 100 mV do 1 V CMC 6,2 µV/V od 1 V do 10 V CMC 5,4 µV/V od 10 V do 1000 V CMC 8,2 µV/V Stejnosmerne napeti / meridla a generatory stejnosmerneho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 0 mV az 100 mV CMC 9 µV/V + 0,3 µV 100 mV az 1 V CMC 6,2 µV/V 1 V az 10 V CMC 5,4 µV/V 10 V az 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_en":"DC voltage / DC voltage meters and generators Calibration – electrical quantities Direct measurement using a multimeter 0 mV to 100 mV CMC 9 µV/V + 0,3 µV 100 mV to 1 V CMC 6,2 µV/V 1 V to 10 V CMC 5,4 µV/V 10 V to 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","search_zh":"直流电压 / 直流电压测量仪器和发生器 校准 – 电学量 用万用表直接测量 0 mV 至 100 mV CMC 9 µV/V + 0,3 µV 100 mV 至 1 V CMC 6,2 µV/V 1 V 至 10 V CMC 5,4 µV/V 10 V 至 1000 V CMC 8,2 µV/V J 62.03.E01.0, J 62.03.E08.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6439d192ea12028fed56873f","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"od 220 µA do 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"od 2,2 mA do 22 mA","cmc":"44 µA/A"},{"name":"","range":"od 22 mA do 220 mA","cmc":"57 µA/A"},{"name":"","range":"od 220 mA do 2,2 A","cmc":"0,01 %"},{"name":"","range":"od 2,2 A do 20 A","cmc":"0,048 %"},{"name":"","range":"od 20 A do 120 A","cmc":"0,035 %"}],"parameters_en":[{"name":"","range":"0 µA to 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"2,2 mA to 22 mA","cmc":"44 µA/A"},{"name":"","range":"22 mA to 220 mA","cmc":"57 µA/A"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,01 %"},{"name":"","range":"2,2 A to 20 A","cmc":"0,048 %"},{"name":"","range":"20 A to 120 A","cmc":"0,035 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"220 µA 至 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"2,2 mA 至 22 mA","cmc":"44 µA/A"},{"name":"","range":"22 mA 至 220 mA","cmc":"57 µA/A"},{"name":"","range":"220 mA 至 2,2 A","cmc":"0,01 %"},{"name":"","range":"2,2 A 至 20 A","cmc":"0,048 %"},{"name":"","range":"20 A 至 120 A","cmc":"0,035 %"}],"parameters_cs":[{"name":"","range":"0 µA až 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"220 µA až 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"2,2 mA až 22 mA","cmc":"44 µA/A"},{"name":"","range":"22 mA až 220 mA","cmc":"57 µA/A"},{"name":"","range":"220 mA až 2,2 A","cmc":"0,01 %"},{"name":"","range":"2,2 A až 20 A","cmc":"0,048 %"},{"name":"","range":"20 A až 120 A","cmc":"0,035 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 220 µA CMC 80 µA/A + 6 nA\nod 220 µA do 2,2 mA CMC 46 µA/A\nod 2,2 mA do 22 mA CMC 44 µA/A\nod 22 mA do 220 mA CMC 57 µA/A\nod 220 mA do 2,2 A CMC 0,01 %\nod 2,2 A do 20 A CMC 0,048 %\nod 20 A do 120 A CMC 0,035 %\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 µA do 220 µA CMC 80 µA/A + 6 nA od 220 µA do 2,2 mA CMC 46 µA/A od 2,2 mA do 22 mA CMC 44 µA/A od 22 mA do 220 mA CMC 57 µA/A od 220 mA do 2,2 A CMC 0,01 % od 2,2 A do 20 A CMC 0,048 % od 20 A do 120 A CMC 0,035 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 µA až 220 µA CMC 80 µA/A + 6 nA 220 µA až 2,2 mA CMC 46 µA/A 2,2 mA až 22 mA CMC 44 µA/A 22 mA až 220 mA CMC 57 µA/A 220 mA až 2,2 A CMC 0,01 % 2,2 A až 20 A CMC 0,048 % 20 A až 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 µA do 220 µA CMC 80 µA/A + 6 nA od 220 µA do 2,2 mA CMC 46 µA/A od 2,2 mA do 22 mA CMC 44 µA/A od 22 mA do 220 mA CMC 57 µA/A od 220 mA do 2,2 A CMC 0,01 % od 2,2 A do 20 A CMC 0,048 % od 20 A do 120 A CMC 0,035 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 µA az 220 µA CMC 80 µA/A + 6 nA 220 µA az 2,2 mA CMC 46 µA/A 2,2 mA az 22 mA CMC 44 µA/A 22 mA az 220 mA CMC 57 µA/A 220 mA az 2,2 A CMC 0,01 % 2,2 A az 20 A CMC 0,048 % 20 A az 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Direct generation with a calibrator 0 µA to 220 µA CMC 80 µA/A + 6 nA 220 µA to 2,2 mA CMC 46 µA/A 2,2 mA to 22 mA CMC 44 µA/A 22 mA to 220 mA CMC 57 µA/A 220 mA to 2,2 A CMC 0,01 % 2,2 A to 20 A CMC 0,048 % 20 A to 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 用校准器直接产生 0 µA 至 220 µA CMC 80 µA/A + 6 nA 220 µA 至 2,2 mA CMC 46 µA/A 2,2 mA 至 22 mA CMC 44 µA/A 22 mA 至 220 mA CMC 57 µA/A 220 mA 至 2,2 A CMC 0,01 % 2,2 A 至 20 A CMC 0,048 % 20 A 至 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b76e603a186a1c25fb8e5b8c","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"od 220 µA do 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"od 2,2 mA do 22 mA","cmc":"44 µA/A"},{"name":"","range":"od 22 mA do 220 mA","cmc":"57 µA/A"},{"name":"","range":"od 220 mA do 2,2 A","cmc":"0,01 %"},{"name":"","range":"od 2,2 A do 20 A","cmc":"0,048 %"},{"name":"","range":"od 20 A do 120 A","cmc":"0,035 %"}],"parameters_en":[{"name":"","range":"0 µA to 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"220 µA to 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"2,2 mA to 22 mA","cmc":"44 µA/A"},{"name":"","range":"22 mA to 220 mA","cmc":"57 µA/A"},{"name":"","range":"220 mA to 2,2 A","cmc":"0,01 %"},{"name":"","range":"2,2 A to 20 A","cmc":"0,048 %"},{"name":"","range":"20 A to 120 A","cmc":"0,035 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"220 µA 至 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"2,2 mA 至 22 mA","cmc":"44 µA/A"},{"name":"","range":"22 mA 至 220 mA","cmc":"57 µA/A"},{"name":"","range":"220 mA 至 2,2 A","cmc":"0,01 %"},{"name":"","range":"2,2 A 至 20 A","cmc":"0,048 %"},{"name":"","range":"20 A 至 120 A","cmc":"0,035 %"}],"parameters_cs":[{"name":"","range":"0 µA až 220 µA","cmc":"80 µA/A + 6 nA"},{"name":"","range":"220 µA až 2,2 mA","cmc":"46 µA/A"},{"name":"","range":"2,2 mA až 22 mA","cmc":"44 µA/A"},{"name":"","range":"22 mA až 220 mA","cmc":"57 µA/A"},{"name":"","range":"220 mA až 2,2 A","cmc":"0,01 %"},{"name":"","range":"2,2 A až 20 A","cmc":"0,048 %"},{"name":"","range":"20 A až 120 A","cmc":"0,035 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 220 µA CMC 80 µA/A + 6 nA\nod 220 µA do 2,2 mA CMC 46 µA/A\nod 2,2 mA do 22 mA CMC 44 µA/A\nod 22 mA do 220 mA CMC 57 µA/A\nod 220 mA do 2,2 A CMC 0,01 %\nod 2,2 A do 20 A CMC 0,048 %\nod 20 A do 120 A CMC 0,035 %\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0 µA do 220 µA CMC 80 µA/A + 6 nA od 220 µA do 2,2 mA CMC 46 µA/A od 2,2 mA do 22 mA CMC 44 µA/A od 22 mA do 220 mA CMC 57 µA/A od 220 mA do 2,2 A CMC 0,01 % od 2,2 A do 20 A CMC 0,048 % od 20 A do 120 A CMC 0,035 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0 µA až 220 µA CMC 80 µA/A + 6 nA 220 µA až 2,2 mA CMC 46 µA/A 2,2 mA až 22 mA CMC 44 µA/A 22 mA až 220 mA CMC 57 µA/A 220 mA až 2,2 A CMC 0,01 % 2,2 A až 20 A CMC 0,048 % 20 A až 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0 µA do 220 µA CMC 80 µA/A + 6 nA od 220 µA do 2,2 mA CMC 46 µA/A od 2,2 mA do 22 mA CMC 44 µA/A od 22 mA do 220 mA CMC 57 µA/A od 220 mA do 2,2 A CMC 0,01 % od 2,2 A do 20 A CMC 0,048 % od 20 A do 120 A CMC 0,035 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Prime generovani kalibratorem 0 µA az 220 µA CMC 80 µA/A + 6 nA 220 µA az 2,2 mA CMC 46 µA/A 2,2 mA az 22 mA CMC 44 µA/A 22 mA az 220 mA CMC 57 µA/A 220 mA az 2,2 A CMC 0,01 % 2,2 A az 20 A CMC 0,048 % 20 A az 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Direct generation with a calibrator 0 µA to 220 µA CMC 80 µA/A + 6 nA 220 µA to 2,2 mA CMC 46 µA/A 2,2 mA to 22 mA CMC 44 µA/A 22 mA to 220 mA CMC 57 µA/A 220 mA to 2,2 A CMC 0,01 % 2,2 A to 20 A CMC 0,048 % 20 A to 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 用校准器直接产生 0 µA 至 220 µA CMC 80 µA/A + 6 nA 220 µA 至 2,2 mA CMC 46 µA/A 2,2 mA 至 22 mA CMC 44 µA/A 22 mA 至 220 mA CMC 57 µA/A 220 mA 至 2,2 A CMC 0,01 % 2,2 A 至 20 A CMC 0,048 % 20 A 至 120 A CMC 0,035 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d4dc6b0008139f42fcae2b5a","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 120 A do 1000 A","cmc":"0,65 %"}],"parameters_en":[{"name":"","range":"120 A to 1000 A","cmc":"0,65 %"}],"parameters_zh":[{"name":"","range":"120 A 至 1000 A","cmc":"0,65 %"}],"parameters_cs":[{"name":"","range":"120 A až 1000 A","cmc":"0,65 %"}],"technique":"Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","technique_en":"Calibrator generation with current simulation using a current coil","technique_zh":"用校准器借助电流线圈模拟电流产生","technique_cs":"Generování kalibrátorem se simulací proudu pomocí proudové cívky","techniques":["Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej"],"techniques_en":["Calibrator generation with current simulation using a current coil"],"techniques_zh":["用校准器借助电流线圈模拟电流产生"],"techniques_cs":["Generování kalibrátorem se simulací proudu pomocí proudové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 120 A do 1000 A CMC 0,65 %\nGenerowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej od 120 A do 1000 A CMC 0,65 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Generování kalibrátorem se simulací proudu pomocí proudové cívky 120 A až 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem z symulacja pradu za pomoca cewki pradowej od 120 A do 1000 A CMC 0,65 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Generovani kalibratorem se simulaci proudu pomoci proudove civky 120 A az 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Calibrator generation with current simulation using a current coil 120 A to 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 用校准器借助电流线圈模拟电流产生 120 A 至 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"32639ca8daa87b9dac83a139","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 120 A do 1000 A","cmc":"0,65 %"}],"parameters_en":[{"name":"","range":"120 A to 1000 A","cmc":"0,65 %"}],"parameters_zh":[{"name":"","range":"120 A 至 1000 A","cmc":"0,65 %"}],"parameters_cs":[{"name":"","range":"120 A až 1000 A","cmc":"0,65 %"}],"technique":"Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","technique_en":"Calibrator generation with current simulation using a current coil","technique_zh":"用校准器借助电流线圈模拟电流产生","technique_cs":"Generování kalibrátorem se simulací proudu pomocí proudové cívky","techniques":["Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej"],"techniques_en":["Calibrator generation with current simulation using a current coil"],"techniques_zh":["用校准器借助电流线圈模拟电流产生"],"techniques_cs":["Generování kalibrátorem se simulací proudu pomocí proudové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 120 A do 1000 A CMC 0,65 %\nGenerowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej od 120 A do 1000 A CMC 0,65 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Generování kalibrátorem se simulací proudu pomocí proudové cívky 120 A až 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem z symulacja pradu za pomoca cewki pradowej od 120 A do 1000 A CMC 0,65 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Generovani kalibratorem se simulaci proudu pomoci proudove civky 120 A az 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Calibrator generation with current simulation using a current coil 120 A to 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 用校准器借助电流线圈模拟电流产生 120 A 至 1000 A CMC 0,65 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"84af95baa01f092e949fee87","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"od 10 µA do 100 µA","cmc":"63 µA/A"},{"name":"","range":"od 100 µA do 1 mA","cmc":"39 µA/A"},{"name":"","range":"od 1 mA do 10 mA","cmc":"38 µA/A"},{"name":"","range":"od 10 mA do 100 mA","cmc":"54 µA/A"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,015 %"}],"parameters_en":[{"name":"","range":"0 µA to 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"63 µA/A"},{"name":"","range":"100 µA to 1 mA","cmc":"39 µA/A"},{"name":"","range":"1 mA to 10 mA","cmc":"38 µA/A"},{"name":"","range":"10 mA to 100 mA","cmc":"54 µA/A"},{"name":"","range":"100 mA to 1 A","cmc":"0,015 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"10 µA 至 100 µA","cmc":"63 µA/A"},{"name":"","range":"100 µA 至 1 mA","cmc":"39 µA/A"},{"name":"","range":"1 mA 至 10 mA","cmc":"38 µA/A"},{"name":"","range":"10 mA 至 100 mA","cmc":"54 µA/A"},{"name":"","range":"100 mA 至 1 A","cmc":"0,015 %"}],"parameters_cs":[{"name":"","range":"0 µA až 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"10 µA až 100 µA","cmc":"63 µA/A"},{"name":"","range":"100 µA až 1 mA","cmc":"39 µA/A"},{"name":"","range":"1 mA až 10 mA","cmc":"38 µA/A"},{"name":"","range":"10 mA až 100 mA","cmc":"54 µA/A"},{"name":"","range":"100 mA až 1 A","cmc":"0,015 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 10 µA CMC 0,018 % + 1,2 nA\nod 10 µA do 100 µA CMC 63 µA/A\nod 100 µA do 1 mA CMC 39 µA/A\nod 1 mA do 10 mA CMC 38 µA/A\nod 10 mA do 100 mA CMC 54 µA/A\nod 100 mA do 1 A CMC 0,015 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 µA do 10 µA CMC 0,018 % + 1,2 nA od 10 µA do 100 µA CMC 63 µA/A od 100 µA do 1 mA CMC 39 µA/A od 1 mA do 10 mA CMC 38 µA/A od 10 mA do 100 mA CMC 54 µA/A od 100 mA do 1 A CMC 0,015 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření multimetrem 0 µA až 10 µA CMC 0,018 % + 1,2 nA 10 µA až 100 µA CMC 63 µA/A 100 µA až 1 mA CMC 39 µA/A 1 mA až 10 mA CMC 38 µA/A 10 mA až 100 mA CMC 54 µA/A 100 mA až 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 µA do 10 µA CMC 0,018 % + 1,2 nA od 10 µA do 100 µA CMC 63 µA/A od 100 µA do 1 mA CMC 39 µA/A od 1 mA do 10 mA CMC 38 µA/A od 10 mA do 100 mA CMC 54 µA/A od 100 mA do 1 A CMC 0,015 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem 0 µA az 10 µA CMC 0,018 % + 1,2 nA 10 µA az 100 µA CMC 63 µA/A 100 µA az 1 mA CMC 39 µA/A 1 mA az 10 mA CMC 38 µA/A 10 mA az 100 mA CMC 54 µA/A 100 mA az 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Direct measurement using a multimeter 0 µA to 10 µA CMC 0,018 % + 1,2 nA 10 µA to 100 µA CMC 63 µA/A 100 µA to 1 mA CMC 39 µA/A 1 mA to 10 mA CMC 38 µA/A 10 mA to 100 mA CMC 54 µA/A 100 mA to 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 用万用表直接测量 0 µA 至 10 µA CMC 0,018 % + 1,2 nA 10 µA 至 100 µA CMC 63 µA/A 100 µA 至 1 mA CMC 39 µA/A 1 mA 至 10 mA CMC 38 µA/A 10 mA 至 100 mA CMC 54 µA/A 100 mA 至 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"24926f043525a80732040a92","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 µA do 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"od 10 µA do 100 µA","cmc":"63 µA/A"},{"name":"","range":"od 100 µA do 1 mA","cmc":"39 µA/A"},{"name":"","range":"od 1 mA do 10 mA","cmc":"38 µA/A"},{"name":"","range":"od 10 mA do 100 mA","cmc":"54 µA/A"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,015 %"}],"parameters_en":[{"name":"","range":"0 µA to 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"10 µA to 100 µA","cmc":"63 µA/A"},{"name":"","range":"100 µA to 1 mA","cmc":"39 µA/A"},{"name":"","range":"1 mA to 10 mA","cmc":"38 µA/A"},{"name":"","range":"10 mA to 100 mA","cmc":"54 µA/A"},{"name":"","range":"100 mA to 1 A","cmc":"0,015 %"}],"parameters_zh":[{"name":"","range":"0 µA 至 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"10 µA 至 100 µA","cmc":"63 µA/A"},{"name":"","range":"100 µA 至 1 mA","cmc":"39 µA/A"},{"name":"","range":"1 mA 至 10 mA","cmc":"38 µA/A"},{"name":"","range":"10 mA 至 100 mA","cmc":"54 µA/A"},{"name":"","range":"100 mA 至 1 A","cmc":"0,015 %"}],"parameters_cs":[{"name":"","range":"0 µA až 10 µA","cmc":"0,018 % + 1,2 nA"},{"name":"","range":"10 µA až 100 µA","cmc":"63 µA/A"},{"name":"","range":"100 µA až 1 mA","cmc":"39 µA/A"},{"name":"","range":"1 mA až 10 mA","cmc":"38 µA/A"},{"name":"","range":"10 mA až 100 mA","cmc":"54 µA/A"},{"name":"","range":"100 mA až 1 A","cmc":"0,015 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 µA do 10 µA CMC 0,018 % + 1,2 nA\nod 10 µA do 100 µA CMC 63 µA/A\nod 100 µA do 1 mA CMC 39 µA/A\nod 1 mA do 10 mA CMC 38 µA/A\nod 10 mA do 100 mA CMC 54 µA/A\nod 100 mA do 1 A CMC 0,015 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0 µA do 10 µA CMC 0,018 % + 1,2 nA od 10 µA do 100 µA CMC 63 µA/A od 100 µA do 1 mA CMC 39 µA/A od 1 mA do 10 mA CMC 38 µA/A od 10 mA do 100 mA CMC 54 µA/A od 100 mA do 1 A CMC 0,015 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření multimetrem 0 µA až 10 µA CMC 0,018 % + 1,2 nA 10 µA až 100 µA CMC 63 µA/A 100 µA až 1 mA CMC 39 µA/A 1 mA až 10 mA CMC 38 µA/A 10 mA až 100 mA CMC 54 µA/A 100 mA až 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0 µA do 10 µA CMC 0,018 % + 1,2 nA od 10 µA do 100 µA CMC 63 µA/A od 100 µA do 1 mA CMC 39 µA/A od 1 mA do 10 mA CMC 38 µA/A od 10 mA do 100 mA CMC 54 µA/A od 100 mA do 1 A CMC 0,015 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem 0 µA az 10 µA CMC 0,018 % + 1,2 nA 10 µA az 100 µA CMC 63 µA/A 100 µA az 1 mA CMC 39 µA/A 1 mA az 10 mA CMC 38 µA/A 10 mA az 100 mA CMC 54 µA/A 100 mA az 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Direct measurement using a multimeter 0 µA to 10 µA CMC 0,018 % + 1,2 nA 10 µA to 100 µA CMC 63 µA/A 100 µA to 1 mA CMC 39 µA/A 1 mA to 10 mA CMC 38 µA/A 10 mA to 100 mA CMC 54 µA/A 100 mA to 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 用万用表直接测量 0 µA 至 10 µA CMC 0,018 % + 1,2 nA 10 µA 至 100 µA CMC 63 µA/A 100 µA 至 1 mA CMC 39 µA/A 1 mA 至 10 mA CMC 38 µA/A 10 mA 至 100 mA CMC 54 µA/A 100 mA 至 1 A CMC 0,015 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"83a08de86069d868193f50bc","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 A do 20 A","cmc":"0,024 %"},{"name":"","range":"od 20 A do 100 A","cmc":"0,058 %"}],"parameters_en":[{"name":"","range":"1 A to 20 A","cmc":"0,024 %"},{"name":"","range":"20 A to 100 A","cmc":"0,058 %"}],"parameters_zh":[{"name":"","range":"1 A 至 20 A","cmc":"0,024 %"},{"name":"","range":"20 A 至 100 A","cmc":"0,058 %"}],"parameters_cs":[{"name":"","range":"1 A až 20 A","cmc":"0,024 %"},{"name":"","range":"20 A až 100 A","cmc":"0,058 %"}],"technique":"Pomiar multimetrem na boczniku prądowym","technique_en":"Measurement with a multimeter on a current shunt","technique_zh":"在电流分流器上用万用表测量","technique_cs":"Měření multimetrem na proudovém bočníku","techniques":["Pomiar multimetrem na boczniku prądowym"],"techniques_en":["Measurement with a multimeter on a current shunt"],"techniques_zh":["在电流分流器上用万用表测量"],"techniques_cs":["Měření multimetrem na proudovém bočníku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 A do 20 A CMC 0,024 %\nod 20 A do 100 A CMC 0,058 %\nPomiar multimetrem na boczniku prądowym","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Pomiar multimetrem na boczniku prądowym od 1 A do 20 A CMC 0,024 % od 20 A do 100 A CMC 0,058 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Měření multimetrem na proudovém bočníku 1 A až 20 A CMC 0,024 % 20 A až 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar multimetrem na boczniku pradowym od 1 A do 20 A CMC 0,024 % od 20 A do 100 A CMC 0,058 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Mereni multimetrem na proudovem bocniku 1 A az 20 A CMC 0,024 % 20 A az 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Measurement with a multimeter on a current shunt 1 A to 20 A CMC 0,024 % 20 A to 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 在电流分流器上用万用表测量 1 A 至 20 A CMC 0,024 % 20 A 至 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"700662e72ac735883c1662e5","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego","test_object_en":"DC current / DC current meters and generators","test_object_zh":"直流电流 / 直流电流测量仪器和发生器","test_object_cs":"Stejnosměrný proud / měřidla a generátory stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 1 A do 20 A","cmc":"0,024 %"},{"name":"","range":"od 20 A do 100 A","cmc":"0,058 %"}],"parameters_en":[{"name":"","range":"1 A to 20 A","cmc":"0,024 %"},{"name":"","range":"20 A to 100 A","cmc":"0,058 %"}],"parameters_zh":[{"name":"","range":"1 A 至 20 A","cmc":"0,024 %"},{"name":"","range":"20 A 至 100 A","cmc":"0,058 %"}],"parameters_cs":[{"name":"","range":"1 A až 20 A","cmc":"0,024 %"},{"name":"","range":"20 A až 100 A","cmc":"0,058 %"}],"technique":"Pomiar multimetrem na boczniku prądowym","technique_en":"Measurement with a multimeter on a current shunt","technique_zh":"在电流分流器上用万用表测量","technique_cs":"Měření multimetrem na proudovém bočníku","techniques":["Pomiar multimetrem na boczniku prądowym"],"techniques_en":["Measurement with a multimeter on a current shunt"],"techniques_zh":["在电流分流器上用万用表测量"],"techniques_cs":["Měření multimetrem na proudovém bočníku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 1 A do 20 A CMC 0,024 %\nod 20 A do 100 A CMC 0,058 %\nPomiar multimetrem na boczniku prądowym","reference":"J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","norm_bases":["J 62.03.E03.0","J 62.03.E10.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru i generatory prądu stałego Wzorcowanie – wielkości elektryczne Pomiar multimetrem na boczniku prądowym od 1 A do 20 A CMC 0,024 % od 20 A do 100 A CMC 0,058 % Stejnosměrný proud / měřidla a generátory stejnosměrného proudu Kalibrace – elektrické veličiny Měření multimetrem na proudovém bočníku 1 A až 20 A CMC 0,024 % 20 A až 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0 Prad staly / przyrzady do pomiaru i generatory pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar multimetrem na boczniku pradowym od 1 A do 20 A CMC 0,024 % od 20 A do 100 A CMC 0,058 % Stejnosmerny proud / meridla a generatory stejnosmerneho proudu Kalibrace – elektricke veliciny Mereni multimetrem na proudovem bocniku 1 A az 20 A CMC 0,024 % 20 A az 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_en":"DC current / DC current meters and generators Calibration – electrical quantities Measurement with a multimeter on a current shunt 1 A to 20 A CMC 0,024 % 20 A to 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","search_zh":"直流电流 / 直流电流测量仪器和发生器 校准 – 电学量 在电流分流器上用万用表测量 1 A 至 20 A CMC 0,024 % 20 A 至 100 A CMC 0,058 % J 62.03.E03.0, J 62.03.E10.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9d4da297b09ce85834939431","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji","test_object_en":"DC resistance / DC resistance meters and generators","test_object_zh":"直流电阻 / 直流电阻测量仪器和发生器","test_object_cs":"Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"od 0,01 Ω do 0,1 Ω","cmc":"1 %"},{"name":"","range":"od 0,1 Ω do 1 Ω","cmc":"0,2 %"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"0,05 %"},{"name":"","range":"od 10 Ω do 100 kΩ","cmc":"0,01 %"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"0,02 %"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,05 %"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,1 %"},{"name":"","range":"od 100 MΩ do 100 GΩ","cmc":"1 %"},{"name":"","range":"od 100 GΩ do 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"1 %"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,2 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"","range":"10 Ω to 100 kΩ","cmc":"0,01 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,02 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,05 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,1 %"},{"name":"","range":"100 MΩ to 100 GΩ","cmc":"1 %"},{"name":"","range":"100 GΩ to 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"parameters_zh":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"0,01 Ω 至 0,1 Ω","cmc":"1 %"},{"name":"","range":"0,1 Ω 至 1 Ω","cmc":"0,2 %"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"0,05 %"},{"name":"","range":"10 Ω 至 100 kΩ","cmc":"0,01 %"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"0,02 %"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,05 %"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,1 %"},{"name":"","range":"100 MΩ 至 100 GΩ","cmc":"1 %"},{"name":"","range":"100 GΩ 至 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"parameters_cs":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"0,01 Ω až 0,1 Ω","cmc":"1 %"},{"name":"","range":"0,1 Ω až 1 Ω","cmc":"0,2 %"},{"name":"","range":"1 Ω až 10 Ω","cmc":"0,05 %"},{"name":"","range":"10 Ω až 100 kΩ","cmc":"0,01 %"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"0,02 %"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,05 %"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,1 %"},{"name":"","range":"100 MΩ až 100 GΩ","cmc":"1 %"},{"name":"","range":"100 GΩ až 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"technique":"Bezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi","technique_en":"Direct generation by calibrator / reference resistors / resistance boxes","technique_zh":"用校准器 / 标准电阻器 / 电阻箱直接产生","technique_cs":"Přímé generování kalibrátorem / etalonovými odpory / odporovými dekádami","techniques":["Bezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi"],"techniques_en":["Direct generation by calibrator / reference resistors / resistance boxes"],"techniques_zh":["用校准器 / 标准电阻器 / 电阻箱直接产生"],"techniques_cs":["Přímé generování kalibrátorem / etalonovými odpory / odporovými dekádami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Ω CMC 50 µΩ\nod 0,01 Ω do 0,1 Ω CMC 1 %\nod 0,1 Ω do 1 Ω CMC 0,2 %\nod 1 Ω do 10 Ω CMC 0,05 %\nod 10 Ω do 100 kΩ CMC 0,01 %\nod 100 kΩ do 1 MΩ CMC 0,02 %\nod 1 MΩ do 10 MΩ CMC 0,05 %\nod 10 MΩ do 100 MΩ CMC 0,1 %\nod 100 MΩ do 100 GΩ CMC 1 %\nod 100 GΩ do 1000 GΩ CMC 4 %\n1 mΩ CMC 0,01 %\n10 mΩ CMC 0,01 %\n100 mΩ CMC 0,01 %\n1 Ω CMC 0,01 %\n1,9 Ω CMC 0,011 %\n10 Ω CMC 27 µΩ/Ω\n19 Ω CMC 27 µΩ/Ω\n100 Ω CMC 12 µΩ/Ω\n190 Ω CMC 12 µΩ/Ω\n1 kΩ CMC 8 µΩ/Ω\n1,9 kΩ CMC 8 µΩ/Ω\n10 kΩ CMC 8 µΩ/Ω\n19 kΩ CMC 8 µΩ/Ω\n100 kΩ CMC 10 µΩ/Ω\n190 kΩ CMC 12 µΩ/Ω\n1 MΩ CMC 15 µΩ/Ω\n1,9 MΩ CMC 21 µΩ/Ω\n10 MΩ CMC 46 µΩ/Ω\n19 MΩ CMC 55 µΩ/Ω\n100 MΩ CMC 0,012 %\n10 GΩ CMC 0,2 %\nBezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi","reference":"J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","norm_bases":["J 62.03.E05.0","J 62.03.E12.0","J 62.03.E13.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi 0 Ω CMC 50 µΩ od 0,01 Ω do 0,1 Ω CMC 1 % od 0,1 Ω do 1 Ω CMC 0,2 % od 1 Ω do 10 Ω CMC 0,05 % od 10 Ω do 100 kΩ CMC 0,01 % od 100 kΩ do 1 MΩ CMC 0,02 % od 1 MΩ do 10 MΩ CMC 0,05 % od 10 MΩ do 100 MΩ CMC 0,1 % od 100 MΩ do 100 GΩ CMC 1 % od 100 GΩ do 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu Kalibrace – elektrické veličiny Přímé generování kalibrátorem / etalonovými odpory / odporovými dekádami 0 Ω CMC 50 µΩ 0,01 Ω až 0,1 Ω CMC 1 % 0,1 Ω až 1 Ω CMC 0,2 % 1 Ω až 10 Ω CMC 0,05 % 10 Ω až 100 kΩ CMC 0,01 % 100 kΩ až 1 MΩ CMC 0,02 % 1 MΩ až 10 MΩ CMC 0,05 % 10 MΩ až 100 MΩ CMC 0,1 % 100 MΩ až 100 GΩ CMC 1 % 100 GΩ až 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 Rezystancja przy pradzie stalym / przyrzady do pomiaru i generatory rezystancji Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi 0 Ω CMC 50 µΩ od 0,01 Ω do 0,1 Ω CMC 1 % od 0,1 Ω do 1 Ω CMC 0,2 % od 1 Ω do 10 Ω CMC 0,05 % od 10 Ω do 100 kΩ CMC 0,01 % od 100 kΩ do 1 MΩ CMC 0,02 % od 1 MΩ do 10 MΩ CMC 0,05 % od 10 MΩ do 100 MΩ CMC 0,1 % od 100 MΩ do 100 GΩ CMC 1 % od 100 GΩ do 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % Stejnosmerny odpor / meridla a generatory stejnosmerneho odporu Kalibrace – elektricke veliciny Prime generovani kalibratorem / etalonovymi odpory / odporovymi dekadami 0 Ω CMC 50 µΩ 0,01 Ω az 0,1 Ω CMC 1 % 0,1 Ω az 1 Ω CMC 0,2 % 1 Ω az 10 Ω CMC 0,05 % 10 Ω az 100 kΩ CMC 0,01 % 100 kΩ az 1 MΩ CMC 0,02 % 1 MΩ az 10 MΩ CMC 0,05 % 10 MΩ az 100 MΩ CMC 0,1 % 100 MΩ az 100 GΩ CMC 1 % 100 GΩ az 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_en":"DC resistance / DC resistance meters and generators Calibration – electrical quantities Direct generation by calibrator / reference resistors / resistance boxes 0 Ω CMC 50 µΩ 0,01 Ω to 0,1 Ω CMC 1 % 0,1 Ω to 1 Ω CMC 0,2 % 1 Ω to 10 Ω CMC 0,05 % 10 Ω to 100 kΩ CMC 0,01 % 100 kΩ to 1 MΩ CMC 0,02 % 1 MΩ to 10 MΩ CMC 0,05 % 10 MΩ to 100 MΩ CMC 0,1 % 100 MΩ to 100 GΩ CMC 1 % 100 GΩ to 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_zh":"直流电阻 / 直流电阻测量仪器和发生器 校准 – 电学量 用校准器 / 标准电阻器 / 电阻箱直接产生 0 Ω CMC 50 µΩ 0,01 Ω 至 0,1 Ω CMC 1 % 0,1 Ω 至 1 Ω CMC 0,2 % 1 Ω 至 10 Ω CMC 0,05 % 10 Ω 至 100 kΩ CMC 0,01 % 100 kΩ 至 1 MΩ CMC 0,02 % 1 MΩ 至 10 MΩ CMC 0,05 % 10 MΩ 至 100 MΩ CMC 0,1 % 100 MΩ 至 100 GΩ CMC 1 % 100 GΩ 至 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3954e5e213771420cb383af9","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji","test_object_en":"DC resistance / DC resistance meters and generators","test_object_zh":"直流电阻 / 直流电阻测量仪器和发生器","test_object_cs":"Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"od 0,01 Ω do 0,1 Ω","cmc":"1 %"},{"name":"","range":"od 0,1 Ω do 1 Ω","cmc":"0,2 %"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"0,05 %"},{"name":"","range":"od 10 Ω do 100 kΩ","cmc":"0,01 %"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"0,02 %"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,05 %"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,1 %"},{"name":"","range":"od 100 MΩ do 100 GΩ","cmc":"1 %"},{"name":"","range":"od 100 GΩ do 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"parameters_en":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"1 %"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,2 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,05 %"},{"name":"","range":"10 Ω to 100 kΩ","cmc":"0,01 %"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"0,02 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,05 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,1 %"},{"name":"","range":"100 MΩ to 100 GΩ","cmc":"1 %"},{"name":"","range":"100 GΩ to 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"parameters_zh":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"0,01 Ω 至 0,1 Ω","cmc":"1 %"},{"name":"","range":"0,1 Ω 至 1 Ω","cmc":"0,2 %"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"0,05 %"},{"name":"","range":"10 Ω 至 100 kΩ","cmc":"0,01 %"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"0,02 %"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,05 %"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,1 %"},{"name":"","range":"100 MΩ 至 100 GΩ","cmc":"1 %"},{"name":"","range":"100 GΩ 至 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"parameters_cs":[{"name":"","range":"0 Ω","cmc":"50 µΩ"},{"name":"","range":"0,01 Ω až 0,1 Ω","cmc":"1 %"},{"name":"","range":"0,1 Ω až 1 Ω","cmc":"0,2 %"},{"name":"","range":"1 Ω až 10 Ω","cmc":"0,05 %"},{"name":"","range":"10 Ω až 100 kΩ","cmc":"0,01 %"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"0,02 %"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,05 %"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,1 %"},{"name":"","range":"100 MΩ až 100 GΩ","cmc":"1 %"},{"name":"","range":"100 GΩ až 1000 GΩ","cmc":"4 %"},{"name":"","range":"1 mΩ","cmc":"0,01 %"},{"name":"","range":"10 mΩ","cmc":"0,01 %"},{"name":"","range":"100 mΩ","cmc":"0,01 %"},{"name":"","range":"1 Ω","cmc":"0,01 %"},{"name":"","range":"1,9 Ω","cmc":"0,011 %"},{"name":"","range":"10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"19 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"100 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"190 Ω","cmc":"12 µΩ/Ω"},{"name":"","range":"1 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"1,9 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"10 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"19 kΩ","cmc":"8 µΩ/Ω"},{"name":"","range":"100 kΩ","cmc":"10 µΩ/Ω"},{"name":"","range":"190 kΩ","cmc":"12 µΩ/Ω"},{"name":"","range":"1 MΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"1,9 MΩ","cmc":"21 µΩ/Ω"},{"name":"","range":"10 MΩ","cmc":"46 µΩ/Ω"},{"name":"","range":"19 MΩ","cmc":"55 µΩ/Ω"},{"name":"","range":"100 MΩ","cmc":"0,012 %"},{"name":"","range":"10 GΩ","cmc":"0,2 %"}],"technique":"Bezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi","technique_en":"Direct generation by calibrator / reference resistors / resistance boxes","technique_zh":"用校准器 / 标准电阻器 / 电阻箱直接产生","technique_cs":"Přímé generování kalibrátorem / etalonovými odpory / odporovými dekádami","techniques":["Bezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi"],"techniques_en":["Direct generation by calibrator / reference resistors / resistance boxes"],"techniques_zh":["用校准器 / 标准电阻器 / 电阻箱直接产生"],"techniques_cs":["Přímé generování kalibrátorem / etalonovými odpory / odporovými dekádami"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0 Ω CMC 50 µΩ\nod 0,01 Ω do 0,1 Ω CMC 1 %\nod 0,1 Ω do 1 Ω CMC 0,2 %\nod 1 Ω do 10 Ω CMC 0,05 %\nod 10 Ω do 100 kΩ CMC 0,01 %\nod 100 kΩ do 1 MΩ CMC 0,02 %\nod 1 MΩ do 10 MΩ CMC 0,05 %\nod 10 MΩ do 100 MΩ CMC 0,1 %\nod 100 MΩ do 100 GΩ CMC 1 %\nod 100 GΩ do 1000 GΩ CMC 4 %\n1 mΩ CMC 0,01 %\n10 mΩ CMC 0,01 %\n100 mΩ CMC 0,01 %\n1 Ω CMC 0,01 %\n1,9 Ω CMC 0,011 %\n10 Ω CMC 27 µΩ/Ω\n19 Ω CMC 27 µΩ/Ω\n100 Ω CMC 12 µΩ/Ω\n190 Ω CMC 12 µΩ/Ω\n1 kΩ CMC 8 µΩ/Ω\n1,9 kΩ CMC 8 µΩ/Ω\n10 kΩ CMC 8 µΩ/Ω\n19 kΩ CMC 8 µΩ/Ω\n100 kΩ CMC 10 µΩ/Ω\n190 kΩ CMC 12 µΩ/Ω\n1 MΩ CMC 15 µΩ/Ω\n1,9 MΩ CMC 21 µΩ/Ω\n10 MΩ CMC 46 µΩ/Ω\n19 MΩ CMC 55 µΩ/Ω\n100 MΩ CMC 0,012 %\n10 GΩ CMC 0,2 %\nBezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi","reference":"J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","norm_bases":["J 62.03.E05.0","J 62.03.E12.0","J 62.03.E13.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi 0 Ω CMC 50 µΩ od 0,01 Ω do 0,1 Ω CMC 1 % od 0,1 Ω do 1 Ω CMC 0,2 % od 1 Ω do 10 Ω CMC 0,05 % od 10 Ω do 100 kΩ CMC 0,01 % od 100 kΩ do 1 MΩ CMC 0,02 % od 1 MΩ do 10 MΩ CMC 0,05 % od 10 MΩ do 100 MΩ CMC 0,1 % od 100 MΩ do 100 GΩ CMC 1 % od 100 GΩ do 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu Kalibrace – elektrické veličiny Přímé generování kalibrátorem / etalonovými odpory / odporovými dekádami 0 Ω CMC 50 µΩ 0,01 Ω až 0,1 Ω CMC 1 % 0,1 Ω až 1 Ω CMC 0,2 % 1 Ω až 10 Ω CMC 0,05 % 10 Ω až 100 kΩ CMC 0,01 % 100 kΩ až 1 MΩ CMC 0,02 % 1 MΩ až 10 MΩ CMC 0,05 % 10 MΩ až 100 MΩ CMC 0,1 % 100 MΩ až 100 GΩ CMC 1 % 100 GΩ až 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 Rezystancja przy pradzie stalym / przyrzady do pomiaru i generatory rezystancji Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem / rezystorami wzorcowymi / dekadami rezystancyjnymi 0 Ω CMC 50 µΩ od 0,01 Ω do 0,1 Ω CMC 1 % od 0,1 Ω do 1 Ω CMC 0,2 % od 1 Ω do 10 Ω CMC 0,05 % od 10 Ω do 100 kΩ CMC 0,01 % od 100 kΩ do 1 MΩ CMC 0,02 % od 1 MΩ do 10 MΩ CMC 0,05 % od 10 MΩ do 100 MΩ CMC 0,1 % od 100 MΩ do 100 GΩ CMC 1 % od 100 GΩ do 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % Stejnosmerny odpor / meridla a generatory stejnosmerneho odporu Kalibrace – elektricke veliciny Prime generovani kalibratorem / etalonovymi odpory / odporovymi dekadami 0 Ω CMC 50 µΩ 0,01 Ω az 0,1 Ω CMC 1 % 0,1 Ω az 1 Ω CMC 0,2 % 1 Ω az 10 Ω CMC 0,05 % 10 Ω az 100 kΩ CMC 0,01 % 100 kΩ az 1 MΩ CMC 0,02 % 1 MΩ az 10 MΩ CMC 0,05 % 10 MΩ az 100 MΩ CMC 0,1 % 100 MΩ az 100 GΩ CMC 1 % 100 GΩ az 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_en":"DC resistance / DC resistance meters and generators Calibration – electrical quantities Direct generation by calibrator / reference resistors / resistance boxes 0 Ω CMC 50 µΩ 0,01 Ω to 0,1 Ω CMC 1 % 0,1 Ω to 1 Ω CMC 0,2 % 1 Ω to 10 Ω CMC 0,05 % 10 Ω to 100 kΩ CMC 0,01 % 100 kΩ to 1 MΩ CMC 0,02 % 1 MΩ to 10 MΩ CMC 0,05 % 10 MΩ to 100 MΩ CMC 0,1 % 100 MΩ to 100 GΩ CMC 1 % 100 GΩ to 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_zh":"直流电阻 / 直流电阻测量仪器和发生器 校准 – 电学量 用校准器 / 标准电阻器 / 电阻箱直接产生 0 Ω CMC 50 µΩ 0,01 Ω 至 0,1 Ω CMC 1 % 0,1 Ω 至 1 Ω CMC 0,2 % 1 Ω 至 10 Ω CMC 0,05 % 10 Ω 至 100 kΩ CMC 0,01 % 100 kΩ 至 1 MΩ CMC 0,02 % 1 MΩ 至 10 MΩ CMC 0,05 % 10 MΩ 至 100 MΩ CMC 0,1 % 100 MΩ 至 100 GΩ CMC 1 % 100 GΩ 至 1000 GΩ CMC 4 % 1 mΩ CMC 0,01 % 10 mΩ CMC 0,01 % 100 mΩ CMC 0,01 % 1 Ω CMC 0,01 % 1,9 Ω CMC 0,011 % 10 Ω CMC 27 µΩ/Ω 19 Ω CMC 27 µΩ/Ω 100 Ω CMC 12 µΩ/Ω 190 Ω CMC 12 µΩ/Ω 1 kΩ CMC 8 µΩ/Ω 1,9 kΩ CMC 8 µΩ/Ω 10 kΩ CMC 8 µΩ/Ω 19 kΩ CMC 8 µΩ/Ω 100 kΩ CMC 10 µΩ/Ω 190 kΩ CMC 12 µΩ/Ω 1 MΩ CMC 15 µΩ/Ω 1,9 MΩ CMC 21 µΩ/Ω 10 MΩ CMC 46 µΩ/Ω 19 MΩ CMC 55 µΩ/Ω 100 MΩ CMC 0,012 % 10 GΩ CMC 0,2 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3b2c4fbb2ecaf31259687d73","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji","test_object_en":"DC resistance / DC resistance meters and generators","test_object_zh":"直流电阻 / 直流电阻测量仪器和发生器","test_object_cs":"Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,01 Ω do 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"od 100 Ω do 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,064 %"},{"name":"","range":"od 100 MΩ do 1 GΩ","cmc":"0,58 %"}],"parameters_en":[{"name":"","range":"0,01 Ω to 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"10 Ω to 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"100 Ω to 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,064 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,58 %"}],"parameters_zh":[{"name":"","range":"0,01 Ω 至 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"100 Ω 至 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,064 %"},{"name":"","range":"100 MΩ 至 1 GΩ","cmc":"0,58 %"}],"parameters_cs":[{"name":"","range":"0,01 Ω až 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"10 Ω až 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"100 Ω až 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,064 %"},{"name":"","range":"100 MΩ až 1 GΩ","cmc":"0,58 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,01 Ω do 10 Ω CMC 27 µΩ/Ω\nod 10 Ω do 100 Ω CMC 22 µΩ/Ω\nod 100 Ω do 10 kΩ CMC 14 µΩ/Ω\nod 10 kΩ do 100 kΩ CMC 15 µΩ/Ω\nod 100 kΩ do 1 MΩ CMC 26 µΩ/Ω\nod 1 MΩ do 10 MΩ CMC 77 µΩ/Ω\nod 10 MΩ do 100 MΩ CMC 0,064 %\nod 100 MΩ do 1 GΩ CMC 0,58 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","norm_bases":["J 62.03.E05.0","J 62.03.E12.0","J 62.03.E13.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0,01 Ω do 10 Ω CMC 27 µΩ/Ω od 10 Ω do 100 Ω CMC 22 µΩ/Ω od 100 Ω do 10 kΩ CMC 14 µΩ/Ω od 10 kΩ do 100 kΩ CMC 15 µΩ/Ω od 100 kΩ do 1 MΩ CMC 26 µΩ/Ω od 1 MΩ do 10 MΩ CMC 77 µΩ/Ω od 10 MΩ do 100 MΩ CMC 0,064 % od 100 MΩ do 1 GΩ CMC 0,58 % Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu Kalibrace – elektrické veličiny Přímé měření multimetrem 0,01 Ω až 10 Ω CMC 27 µΩ/Ω 10 Ω až 100 Ω CMC 22 µΩ/Ω 100 Ω až 10 kΩ CMC 14 µΩ/Ω 10 kΩ až 100 kΩ CMC 15 µΩ/Ω 100 kΩ až 1 MΩ CMC 26 µΩ/Ω 1 MΩ až 10 MΩ CMC 77 µΩ/Ω 10 MΩ až 100 MΩ CMC 0,064 % 100 MΩ až 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 Rezystancja przy pradzie stalym / przyrzady do pomiaru i generatory rezystancji Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0,01 Ω do 10 Ω CMC 27 µΩ/Ω od 10 Ω do 100 Ω CMC 22 µΩ/Ω od 100 Ω do 10 kΩ CMC 14 µΩ/Ω od 10 kΩ do 100 kΩ CMC 15 µΩ/Ω od 100 kΩ do 1 MΩ CMC 26 µΩ/Ω od 1 MΩ do 10 MΩ CMC 77 µΩ/Ω od 10 MΩ do 100 MΩ CMC 0,064 % od 100 MΩ do 1 GΩ CMC 0,58 % Stejnosmerny odpor / meridla a generatory stejnosmerneho odporu Kalibrace – elektricke veliciny Prime mereni multimetrem 0,01 Ω az 10 Ω CMC 27 µΩ/Ω 10 Ω az 100 Ω CMC 22 µΩ/Ω 100 Ω az 10 kΩ CMC 14 µΩ/Ω 10 kΩ az 100 kΩ CMC 15 µΩ/Ω 100 kΩ az 1 MΩ CMC 26 µΩ/Ω 1 MΩ az 10 MΩ CMC 77 µΩ/Ω 10 MΩ az 100 MΩ CMC 0,064 % 100 MΩ az 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_en":"DC resistance / DC resistance meters and generators Calibration – electrical quantities Direct measurement using a multimeter 0,01 Ω to 10 Ω CMC 27 µΩ/Ω 10 Ω to 100 Ω CMC 22 µΩ/Ω 100 Ω to 10 kΩ CMC 14 µΩ/Ω 10 kΩ to 100 kΩ CMC 15 µΩ/Ω 100 kΩ to 1 MΩ CMC 26 µΩ/Ω 1 MΩ to 10 MΩ CMC 77 µΩ/Ω 10 MΩ to 100 MΩ CMC 0,064 % 100 MΩ to 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_zh":"直流电阻 / 直流电阻测量仪器和发生器 校准 – 电学量 用万用表直接测量 0,01 Ω 至 10 Ω CMC 27 µΩ/Ω 10 Ω 至 100 Ω CMC 22 µΩ/Ω 100 Ω 至 10 kΩ CMC 14 µΩ/Ω 10 kΩ 至 100 kΩ CMC 15 µΩ/Ω 100 kΩ 至 1 MΩ CMC 26 µΩ/Ω 1 MΩ 至 10 MΩ CMC 77 µΩ/Ω 10 MΩ 至 100 MΩ CMC 0,064 % 100 MΩ 至 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0692e8e35daa4720a281512a","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"3","test_object":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji","test_object_en":"DC resistance / DC resistance meters and generators","test_object_zh":"直流电阻 / 直流电阻测量仪器和发生器","test_object_cs":"Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,01 Ω do 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"od 100 Ω do 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"od 10 kΩ do 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"od 100 kΩ do 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,064 %"},{"name":"","range":"od 100 MΩ do 1 GΩ","cmc":"0,58 %"}],"parameters_en":[{"name":"","range":"0,01 Ω to 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"10 Ω to 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"100 Ω to 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"10 kΩ to 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"100 kΩ to 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,064 %"},{"name":"","range":"100 MΩ to 1 GΩ","cmc":"0,58 %"}],"parameters_zh":[{"name":"","range":"0,01 Ω 至 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"100 Ω 至 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"10 kΩ 至 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"100 kΩ 至 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,064 %"},{"name":"","range":"100 MΩ 至 1 GΩ","cmc":"0,58 %"}],"parameters_cs":[{"name":"","range":"0,01 Ω až 10 Ω","cmc":"27 µΩ/Ω"},{"name":"","range":"10 Ω až 100 Ω","cmc":"22 µΩ/Ω"},{"name":"","range":"100 Ω až 10 kΩ","cmc":"14 µΩ/Ω"},{"name":"","range":"10 kΩ až 100 kΩ","cmc":"15 µΩ/Ω"},{"name":"","range":"100 kΩ až 1 MΩ","cmc":"26 µΩ/Ω"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"77 µΩ/Ω"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,064 %"},{"name":"","range":"100 MΩ až 1 GΩ","cmc":"0,58 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,01 Ω do 10 Ω CMC 27 µΩ/Ω\nod 10 Ω do 100 Ω CMC 22 µΩ/Ω\nod 100 Ω do 10 kΩ CMC 14 µΩ/Ω\nod 10 kΩ do 100 kΩ CMC 15 µΩ/Ω\nod 100 kΩ do 1 MΩ CMC 26 µΩ/Ω\nod 1 MΩ do 10 MΩ CMC 77 µΩ/Ω\nod 10 MΩ do 100 MΩ CMC 0,064 %\nod 100 MΩ do 1 GΩ CMC 0,58 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","norm_bases":["J 62.03.E05.0","J 62.03.E12.0","J 62.03.E13.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / przyrządy do pomiaru i generatory rezystancji Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem od 0,01 Ω do 10 Ω CMC 27 µΩ/Ω od 10 Ω do 100 Ω CMC 22 µΩ/Ω od 100 Ω do 10 kΩ CMC 14 µΩ/Ω od 10 kΩ do 100 kΩ CMC 15 µΩ/Ω od 100 kΩ do 1 MΩ CMC 26 µΩ/Ω od 1 MΩ do 10 MΩ CMC 77 µΩ/Ω od 10 MΩ do 100 MΩ CMC 0,064 % od 100 MΩ do 1 GΩ CMC 0,58 % Stejnosměrný odpor / měřidla a generátory stejnosměrného odporu Kalibrace – elektrické veličiny Přímé měření multimetrem 0,01 Ω až 10 Ω CMC 27 µΩ/Ω 10 Ω až 100 Ω CMC 22 µΩ/Ω 100 Ω až 10 kΩ CMC 14 µΩ/Ω 10 kΩ až 100 kΩ CMC 15 µΩ/Ω 100 kΩ až 1 MΩ CMC 26 µΩ/Ω 1 MΩ až 10 MΩ CMC 77 µΩ/Ω 10 MΩ až 100 MΩ CMC 0,064 % 100 MΩ až 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0 Rezystancja przy pradzie stalym / przyrzady do pomiaru i generatory rezystancji Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem od 0,01 Ω do 10 Ω CMC 27 µΩ/Ω od 10 Ω do 100 Ω CMC 22 µΩ/Ω od 100 Ω do 10 kΩ CMC 14 µΩ/Ω od 10 kΩ do 100 kΩ CMC 15 µΩ/Ω od 100 kΩ do 1 MΩ CMC 26 µΩ/Ω od 1 MΩ do 10 MΩ CMC 77 µΩ/Ω od 10 MΩ do 100 MΩ CMC 0,064 % od 100 MΩ do 1 GΩ CMC 0,58 % Stejnosmerny odpor / meridla a generatory stejnosmerneho odporu Kalibrace – elektricke veliciny Prime mereni multimetrem 0,01 Ω az 10 Ω CMC 27 µΩ/Ω 10 Ω az 100 Ω CMC 22 µΩ/Ω 100 Ω az 10 kΩ CMC 14 µΩ/Ω 10 kΩ az 100 kΩ CMC 15 µΩ/Ω 100 kΩ az 1 MΩ CMC 26 µΩ/Ω 1 MΩ az 10 MΩ CMC 77 µΩ/Ω 10 MΩ az 100 MΩ CMC 0,064 % 100 MΩ az 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_en":"DC resistance / DC resistance meters and generators Calibration – electrical quantities Direct measurement using a multimeter 0,01 Ω to 10 Ω CMC 27 µΩ/Ω 10 Ω to 100 Ω CMC 22 µΩ/Ω 100 Ω to 10 kΩ CMC 14 µΩ/Ω 10 kΩ to 100 kΩ CMC 15 µΩ/Ω 100 kΩ to 1 MΩ CMC 26 µΩ/Ω 1 MΩ to 10 MΩ CMC 77 µΩ/Ω 10 MΩ to 100 MΩ CMC 0,064 % 100 MΩ to 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","search_zh":"直流电阻 / 直流电阻测量仪器和发生器 校准 – 电学量 用万用表直接测量 0,01 Ω 至 10 Ω CMC 27 µΩ/Ω 10 Ω 至 100 Ω CMC 22 µΩ/Ω 100 Ω 至 10 kΩ CMC 14 µΩ/Ω 10 kΩ 至 100 kΩ CMC 15 µΩ/Ω 100 kΩ 至 1 MΩ CMC 26 µΩ/Ω 1 MΩ 至 10 MΩ CMC 77 µΩ/Ω 10 MΩ 至 100 MΩ CMC 0,064 % 100 MΩ 至 1 GΩ CMC 0,58 % J 62.03.E05.0, J 62.03.E12.0, J 62.03.E13.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4250977336819fc4405d45b1","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters and generators","test_object_zh":"交流电压 / 交流电压测量仪器和发生器","test_object_cs":"Střídavé napětí / měřidla a generátory střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 20 kHz","range":"od 1 mV do 22 mV","cmc":"0,41 %"},{"name":"40 Hz do 20 kHz","range":"od 22 mV do 220 mV","cmc":"0,038 %"},{"name":"40 Hz do 20 kHz","range":"od 220 mV do 2,2 V","cmc":"0,015 %"},{"name":"40 Hz do 20 kHz","range":"od 2,2 V do 11 V","cmc":"59 µV/V"},{"name":"40 Hz do 20 kHz","range":"od 11 V do 22 V","cmc":"57 µV/V"},{"name":"40 Hz do 20 kHz","range":"od 22 V do 220 V","cmc":"65 µV/V"},{"name":"50 Hz do 1 kHz","range":"od 220 V do 1100 V","cmc":"97 µV/V"}],"parameters_en":[{"name":"40 Hz to 20 kHz","range":"1 mV to 22 mV","cmc":"0,41 %"},{"name":"40 Hz to 20 kHz","range":"22 mV to 220 mV","cmc":"0,038 %"},{"name":"40 Hz to 20 kHz","range":"220 mV to 2,2 V","cmc":"0,015 %"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 11 V","cmc":"59 µV/V"},{"name":"40 Hz to 20 kHz","range":"11 V to 22 V","cmc":"57 µV/V"},{"name":"40 Hz to 20 kHz","range":"22 V to 220 V","cmc":"65 µV/V"},{"name":"50 Hz to 1 kHz","range":"220 V to 1100 V","cmc":"97 µV/V"}],"parameters_zh":[{"name":"40 Hz 至 20 kHz","range":"1 mV 至 22 mV","cmc":"0,41 %"},{"name":"40 Hz 至 20 kHz","range":"22 mV 至 220 mV","cmc":"0,038 %"},{"name":"40 Hz 至 20 kHz","range":"220 mV 至 2,2 V","cmc":"0,015 %"},{"name":"40 Hz 至 20 kHz","range":"2,2 V 至 11 V","cmc":"59 µV/V"},{"name":"40 Hz 至 20 kHz","range":"11 V 至 22 V","cmc":"57 µV/V"},{"name":"40 Hz 至 20 kHz","range":"22 V 至 220 V","cmc":"65 µV/V"},{"name":"50 Hz 至 1 kHz","range":"220 V 至 1100 V","cmc":"97 µV/V"}],"parameters_cs":[{"name":"40 Hz až 20 kHz","range":"1 mV až 22 mV","cmc":"0,41 %"},{"name":"40 Hz až 20 kHz","range":"22 mV až 220 mV","cmc":"0,038 %"},{"name":"40 Hz až 20 kHz","range":"220 mV až 2,2 V","cmc":"0,015 %"},{"name":"40 Hz až 20 kHz","range":"2,2 V až 11 V","cmc":"59 µV/V"},{"name":"40 Hz až 20 kHz","range":"11 V až 22 V","cmc":"57 µV/V"},{"name":"40 Hz až 20 kHz","range":"22 V až 220 V","cmc":"65 µV/V"},{"name":"50 Hz až 1 kHz","range":"220 V až 1100 V","cmc":"97 µV/V"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 20 kHz od 1 mV do 22 mV CMC 0,41 %\n40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,038 %\n40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,015 %\n40 Hz do 20 kHz od 2,2 V do 11 V CMC 59 µV/V\n40 Hz do 20 kHz od 11 V do 22 V CMC 57 µV/V\n40 Hz do 20 kHz od 22 V do 220 V CMC 65 µV/V\n50 Hz do 1 kHz od 220 V do 1100 V CMC 97 µV/V\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","norm_bases":["J 62.03.E02.0","J 62.03.E09.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 40 Hz do 20 kHz od 1 mV do 22 mV CMC 0,41 % 40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,038 % 40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,015 % 40 Hz do 20 kHz od 2,2 V do 11 V CMC 59 µV/V 40 Hz do 20 kHz od 11 V do 22 V CMC 57 µV/V 40 Hz do 20 kHz od 22 V do 220 V CMC 65 µV/V 50 Hz do 1 kHz od 220 V do 1100 V CMC 97 µV/V Střídavé napětí / měřidla a generátory střídavého napětí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 40 Hz až 20 kHz 1 mV až 22 mV CMC 0,41 % 40 Hz až 20 kHz 22 mV až 220 mV CMC 0,038 % 40 Hz až 20 kHz 220 mV až 2,2 V CMC 0,015 % 40 Hz až 20 kHz 2,2 V až 11 V CMC 59 µV/V 40 Hz až 20 kHz 11 V až 22 V CMC 57 µV/V 40 Hz až 20 kHz 22 V až 220 V CMC 65 µV/V 50 Hz až 1 kHz 220 V až 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 Napiecie przemienne / przyrzady do pomiaru i generatory napiecia przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 40 Hz do 20 kHz od 1 mV do 22 mV CMC 0,41 % 40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,038 % 40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,015 % 40 Hz do 20 kHz od 2,2 V do 11 V CMC 59 µV/V 40 Hz do 20 kHz od 11 V do 22 V CMC 57 µV/V 40 Hz do 20 kHz od 22 V do 220 V CMC 65 µV/V 50 Hz do 1 kHz od 220 V do 1100 V CMC 97 µV/V Stridave napeti / meridla a generatory stridaveho napeti Kalibrace – elektricke veliciny Prime generovani kalibratorem 40 Hz az 20 kHz 1 mV az 22 mV CMC 0,41 % 40 Hz az 20 kHz 22 mV az 220 mV CMC 0,038 % 40 Hz az 20 kHz 220 mV az 2,2 V CMC 0,015 % 40 Hz az 20 kHz 2,2 V az 11 V CMC 59 µV/V 40 Hz az 20 kHz 11 V az 22 V CMC 57 µV/V 40 Hz az 20 kHz 22 V az 220 V CMC 65 µV/V 50 Hz az 1 kHz 220 V az 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_en":"AC voltage / AC voltage meters and generators Calibration – electrical quantities Direct generation with a calibrator 40 Hz to 20 kHz 1 mV to 22 mV CMC 0,41 % 40 Hz to 20 kHz 22 mV to 220 mV CMC 0,038 % 40 Hz to 20 kHz 220 mV to 2,2 V CMC 0,015 % 40 Hz to 20 kHz 2,2 V to 11 V CMC 59 µV/V 40 Hz to 20 kHz 11 V to 22 V CMC 57 µV/V 40 Hz to 20 kHz 22 V to 220 V CMC 65 µV/V 50 Hz to 1 kHz 220 V to 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_zh":"交流电压 / 交流电压测量仪器和发生器 校准 – 电学量 用校准器直接产生 40 Hz 至 20 kHz 1 mV 至 22 mV CMC 0,41 % 40 Hz 至 20 kHz 22 mV 至 220 mV CMC 0,038 % 40 Hz 至 20 kHz 220 mV 至 2,2 V CMC 0,015 % 40 Hz 至 20 kHz 2,2 V 至 11 V CMC 59 µV/V 40 Hz 至 20 kHz 11 V 至 22 V CMC 57 µV/V 40 Hz 至 20 kHz 22 V 至 220 V CMC 65 µV/V 50 Hz 至 1 kHz 220 V 至 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67fdd7203169de8c91030ed0","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters and generators","test_object_zh":"交流电压 / 交流电压测量仪器和发生器","test_object_cs":"Střídavé napětí / měřidla a generátory střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 20 kHz","range":"od 1 mV do 22 mV","cmc":"0,41 %"},{"name":"40 Hz do 20 kHz","range":"od 22 mV do 220 mV","cmc":"0,038 %"},{"name":"40 Hz do 20 kHz","range":"od 220 mV do 2,2 V","cmc":"0,015 %"},{"name":"40 Hz do 20 kHz","range":"od 2,2 V do 11 V","cmc":"59 µV/V"},{"name":"40 Hz do 20 kHz","range":"od 11 V do 22 V","cmc":"57 µV/V"},{"name":"40 Hz do 20 kHz","range":"od 22 V do 220 V","cmc":"65 µV/V"},{"name":"50 Hz do 1 kHz","range":"od 220 V do 1100 V","cmc":"97 µV/V"}],"parameters_en":[{"name":"40 Hz to 20 kHz","range":"1 mV to 22 mV","cmc":"0,41 %"},{"name":"40 Hz to 20 kHz","range":"22 mV to 220 mV","cmc":"0,038 %"},{"name":"40 Hz to 20 kHz","range":"220 mV to 2,2 V","cmc":"0,015 %"},{"name":"40 Hz to 20 kHz","range":"2,2 V to 11 V","cmc":"59 µV/V"},{"name":"40 Hz to 20 kHz","range":"11 V to 22 V","cmc":"57 µV/V"},{"name":"40 Hz to 20 kHz","range":"22 V to 220 V","cmc":"65 µV/V"},{"name":"50 Hz to 1 kHz","range":"220 V to 1100 V","cmc":"97 µV/V"}],"parameters_zh":[{"name":"40 Hz 至 20 kHz","range":"1 mV 至 22 mV","cmc":"0,41 %"},{"name":"40 Hz 至 20 kHz","range":"22 mV 至 220 mV","cmc":"0,038 %"},{"name":"40 Hz 至 20 kHz","range":"220 mV 至 2,2 V","cmc":"0,015 %"},{"name":"40 Hz 至 20 kHz","range":"2,2 V 至 11 V","cmc":"59 µV/V"},{"name":"40 Hz 至 20 kHz","range":"11 V 至 22 V","cmc":"57 µV/V"},{"name":"40 Hz 至 20 kHz","range":"22 V 至 220 V","cmc":"65 µV/V"},{"name":"50 Hz 至 1 kHz","range":"220 V 至 1100 V","cmc":"97 µV/V"}],"parameters_cs":[{"name":"40 Hz až 20 kHz","range":"1 mV až 22 mV","cmc":"0,41 %"},{"name":"40 Hz až 20 kHz","range":"22 mV až 220 mV","cmc":"0,038 %"},{"name":"40 Hz až 20 kHz","range":"220 mV až 2,2 V","cmc":"0,015 %"},{"name":"40 Hz až 20 kHz","range":"2,2 V až 11 V","cmc":"59 µV/V"},{"name":"40 Hz až 20 kHz","range":"11 V až 22 V","cmc":"57 µV/V"},{"name":"40 Hz až 20 kHz","range":"22 V až 220 V","cmc":"65 µV/V"},{"name":"50 Hz až 1 kHz","range":"220 V až 1100 V","cmc":"97 µV/V"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 20 kHz od 1 mV do 22 mV CMC 0,41 %\n40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,038 %\n40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,015 %\n40 Hz do 20 kHz od 2,2 V do 11 V CMC 59 µV/V\n40 Hz do 20 kHz od 11 V do 22 V CMC 57 µV/V\n40 Hz do 20 kHz od 22 V do 220 V CMC 65 µV/V\n50 Hz do 1 kHz od 220 V do 1100 V CMC 97 µV/V\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","norm_bases":["J 62.03.E02.0","J 62.03.E09.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 40 Hz do 20 kHz od 1 mV do 22 mV CMC 0,41 % 40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,038 % 40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,015 % 40 Hz do 20 kHz od 2,2 V do 11 V CMC 59 µV/V 40 Hz do 20 kHz od 11 V do 22 V CMC 57 µV/V 40 Hz do 20 kHz od 22 V do 220 V CMC 65 µV/V 50 Hz do 1 kHz od 220 V do 1100 V CMC 97 µV/V Střídavé napětí / měřidla a generátory střídavého napětí Kalibrace – elektrické veličiny Přímé generování kalibrátorem 40 Hz až 20 kHz 1 mV až 22 mV CMC 0,41 % 40 Hz až 20 kHz 22 mV až 220 mV CMC 0,038 % 40 Hz až 20 kHz 220 mV až 2,2 V CMC 0,015 % 40 Hz až 20 kHz 2,2 V až 11 V CMC 59 µV/V 40 Hz až 20 kHz 11 V až 22 V CMC 57 µV/V 40 Hz až 20 kHz 22 V až 220 V CMC 65 µV/V 50 Hz až 1 kHz 220 V až 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 Napiecie przemienne / przyrzady do pomiaru i generatory napiecia przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 40 Hz do 20 kHz od 1 mV do 22 mV CMC 0,41 % 40 Hz do 20 kHz od 22 mV do 220 mV CMC 0,038 % 40 Hz do 20 kHz od 220 mV do 2,2 V CMC 0,015 % 40 Hz do 20 kHz od 2,2 V do 11 V CMC 59 µV/V 40 Hz do 20 kHz od 11 V do 22 V CMC 57 µV/V 40 Hz do 20 kHz od 22 V do 220 V CMC 65 µV/V 50 Hz do 1 kHz od 220 V do 1100 V CMC 97 µV/V Stridave napeti / meridla a generatory stridaveho napeti Kalibrace – elektricke veliciny Prime generovani kalibratorem 40 Hz az 20 kHz 1 mV az 22 mV CMC 0,41 % 40 Hz az 20 kHz 22 mV az 220 mV CMC 0,038 % 40 Hz az 20 kHz 220 mV az 2,2 V CMC 0,015 % 40 Hz az 20 kHz 2,2 V az 11 V CMC 59 µV/V 40 Hz az 20 kHz 11 V az 22 V CMC 57 µV/V 40 Hz az 20 kHz 22 V az 220 V CMC 65 µV/V 50 Hz az 1 kHz 220 V az 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_en":"AC voltage / AC voltage meters and generators Calibration – electrical quantities Direct generation with a calibrator 40 Hz to 20 kHz 1 mV to 22 mV CMC 0,41 % 40 Hz to 20 kHz 22 mV to 220 mV CMC 0,038 % 40 Hz to 20 kHz 220 mV to 2,2 V CMC 0,015 % 40 Hz to 20 kHz 2,2 V to 11 V CMC 59 µV/V 40 Hz to 20 kHz 11 V to 22 V CMC 57 µV/V 40 Hz to 20 kHz 22 V to 220 V CMC 65 µV/V 50 Hz to 1 kHz 220 V to 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_zh":"交流电压 / 交流电压测量仪器和发生器 校准 – 电学量 用校准器直接产生 40 Hz 至 20 kHz 1 mV 至 22 mV CMC 0,41 % 40 Hz 至 20 kHz 22 mV 至 220 mV CMC 0,038 % 40 Hz 至 20 kHz 220 mV 至 2,2 V CMC 0,015 % 40 Hz 至 20 kHz 2,2 V 至 11 V CMC 59 µV/V 40 Hz 至 20 kHz 11 V 至 22 V CMC 57 µV/V 40 Hz 至 20 kHz 22 V 至 220 V CMC 65 µV/V 50 Hz 至 1 kHz 220 V 至 1100 V CMC 97 µV/V J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b60dd55d58c1e122fba0bfd","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters and generators","test_object_zh":"交流电压 / 交流电压测量仪器和发生器","test_object_cs":"Střídavé napětí / měřidla a generátory střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 20 kHz","range":"od 1 mV do 10 mV","cmc":"0,14 %"},{"name":"40 Hz do 20 kHz","range":"od 10 mV do 10 V","cmc":"0,034 %"},{"name":"40 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,040 %"},{"name":"40 Hz do 20 kHz","range":"od 100 V do 1000 V","cmc":"0,080 %"}],"parameters_en":[{"name":"40 Hz to 20 kHz","range":"1 mV to 10 mV","cmc":"0,14 %"},{"name":"40 Hz to 20 kHz","range":"10 mV to 10 V","cmc":"0,034 %"},{"name":"40 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,040 %"},{"name":"40 Hz to 20 kHz","range":"100 V to 1000 V","cmc":"0,080 %"}],"parameters_zh":[{"name":"40 Hz 至 20 kHz","range":"1 mV 至 10 mV","cmc":"0,14 %"},{"name":"40 Hz 至 20 kHz","range":"10 mV 至 10 V","cmc":"0,034 %"},{"name":"40 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,040 %"},{"name":"40 Hz 至 20 kHz","range":"100 V 至 1000 V","cmc":"0,080 %"}],"parameters_cs":[{"name":"40 Hz až 20 kHz","range":"1 mV až 10 mV","cmc":"0,14 %"},{"name":"40 Hz až 20 kHz","range":"10 mV až 10 V","cmc":"0,034 %"},{"name":"40 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,040 %"},{"name":"40 Hz až 20 kHz","range":"100 V až 1000 V","cmc":"0,080 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 20 kHz od 1 mV do 10 mV CMC 0,14 %\n40 Hz do 20 kHz od 10 mV do 10 V CMC 0,034 %\n40 Hz do 20 kHz od 10 V do 100 V CMC 0,040 %\n40 Hz do 20 kHz od 100 V do 1000 V CMC 0,080 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","norm_bases":["J 62.03.E02.0","J 62.03.E09.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 40 Hz do 20 kHz od 1 mV do 10 mV CMC 0,14 % 40 Hz do 20 kHz od 10 mV do 10 V CMC 0,034 % 40 Hz do 20 kHz od 10 V do 100 V CMC 0,040 % 40 Hz do 20 kHz od 100 V do 1000 V CMC 0,080 % Střídavé napětí / měřidla a generátory střídavého napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 40 Hz až 20 kHz 1 mV až 10 mV CMC 0,14 % 40 Hz až 20 kHz 10 mV až 10 V CMC 0,034 % 40 Hz až 20 kHz 10 V až 100 V CMC 0,040 % 40 Hz až 20 kHz 100 V až 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 Napiecie przemienne / przyrzady do pomiaru i generatory napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 40 Hz do 20 kHz od 1 mV do 10 mV CMC 0,14 % 40 Hz do 20 kHz od 10 mV do 10 V CMC 0,034 % 40 Hz do 20 kHz od 10 V do 100 V CMC 0,040 % 40 Hz do 20 kHz od 100 V do 1000 V CMC 0,080 % Stridave napeti / meridla a generatory stridaveho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 40 Hz az 20 kHz 1 mV az 10 mV CMC 0,14 % 40 Hz az 20 kHz 10 mV az 10 V CMC 0,034 % 40 Hz az 20 kHz 10 V az 100 V CMC 0,040 % 40 Hz az 20 kHz 100 V az 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_en":"AC voltage / AC voltage meters and generators Calibration – electrical quantities Direct measurement using a multimeter 40 Hz to 20 kHz 1 mV to 10 mV CMC 0,14 % 40 Hz to 20 kHz 10 mV to 10 V CMC 0,034 % 40 Hz to 20 kHz 10 V to 100 V CMC 0,040 % 40 Hz to 20 kHz 100 V to 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_zh":"交流电压 / 交流电压测量仪器和发生器 校准 – 电学量 用万用表直接测量 40 Hz 至 20 kHz 1 mV 至 10 mV CMC 0,14 % 40 Hz 至 20 kHz 10 mV 至 10 V CMC 0,034 % 40 Hz 至 20 kHz 10 V 至 100 V CMC 0,040 % 40 Hz 至 20 kHz 100 V 至 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bea055b728dfc73b59bfdd4","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego","test_object_en":"AC voltage / AC voltage meters and generators","test_object_zh":"交流电压 / 交流电压测量仪器和发生器","test_object_cs":"Střídavé napětí / měřidla a generátory střídavého napětí","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 20 kHz","range":"od 1 mV do 10 mV","cmc":"0,14 %"},{"name":"40 Hz do 20 kHz","range":"od 10 mV do 10 V","cmc":"0,034 %"},{"name":"40 Hz do 20 kHz","range":"od 10 V do 100 V","cmc":"0,040 %"},{"name":"40 Hz do 20 kHz","range":"od 100 V do 1000 V","cmc":"0,080 %"}],"parameters_en":[{"name":"40 Hz to 20 kHz","range":"1 mV to 10 mV","cmc":"0,14 %"},{"name":"40 Hz to 20 kHz","range":"10 mV to 10 V","cmc":"0,034 %"},{"name":"40 Hz to 20 kHz","range":"10 V to 100 V","cmc":"0,040 %"},{"name":"40 Hz to 20 kHz","range":"100 V to 1000 V","cmc":"0,080 %"}],"parameters_zh":[{"name":"40 Hz 至 20 kHz","range":"1 mV 至 10 mV","cmc":"0,14 %"},{"name":"40 Hz 至 20 kHz","range":"10 mV 至 10 V","cmc":"0,034 %"},{"name":"40 Hz 至 20 kHz","range":"10 V 至 100 V","cmc":"0,040 %"},{"name":"40 Hz 至 20 kHz","range":"100 V 至 1000 V","cmc":"0,080 %"}],"parameters_cs":[{"name":"40 Hz až 20 kHz","range":"1 mV až 10 mV","cmc":"0,14 %"},{"name":"40 Hz až 20 kHz","range":"10 mV až 10 V","cmc":"0,034 %"},{"name":"40 Hz až 20 kHz","range":"10 V až 100 V","cmc":"0,040 %"},{"name":"40 Hz až 20 kHz","range":"100 V až 1000 V","cmc":"0,080 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 20 kHz od 1 mV do 10 mV CMC 0,14 %\n40 Hz do 20 kHz od 10 mV do 10 V CMC 0,034 %\n40 Hz do 20 kHz od 10 V do 100 V CMC 0,040 %\n40 Hz do 20 kHz od 100 V do 1000 V CMC 0,080 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","norm_bases":["J 62.03.E02.0","J 62.03.E09.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / przyrządy do pomiaru i generatory napięcia przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 40 Hz do 20 kHz od 1 mV do 10 mV CMC 0,14 % 40 Hz do 20 kHz od 10 mV do 10 V CMC 0,034 % 40 Hz do 20 kHz od 10 V do 100 V CMC 0,040 % 40 Hz do 20 kHz od 100 V do 1000 V CMC 0,080 % Střídavé napětí / měřidla a generátory střídavého napětí Kalibrace – elektrické veličiny Přímé měření multimetrem 40 Hz až 20 kHz 1 mV až 10 mV CMC 0,14 % 40 Hz až 20 kHz 10 mV až 10 V CMC 0,034 % 40 Hz až 20 kHz 10 V až 100 V CMC 0,040 % 40 Hz až 20 kHz 100 V až 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0 Napiecie przemienne / przyrzady do pomiaru i generatory napiecia przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 40 Hz do 20 kHz od 1 mV do 10 mV CMC 0,14 % 40 Hz do 20 kHz od 10 mV do 10 V CMC 0,034 % 40 Hz do 20 kHz od 10 V do 100 V CMC 0,040 % 40 Hz do 20 kHz od 100 V do 1000 V CMC 0,080 % Stridave napeti / meridla a generatory stridaveho napeti Kalibrace – elektricke veliciny Prime mereni multimetrem 40 Hz az 20 kHz 1 mV az 10 mV CMC 0,14 % 40 Hz az 20 kHz 10 mV az 10 V CMC 0,034 % 40 Hz az 20 kHz 10 V az 100 V CMC 0,040 % 40 Hz az 20 kHz 100 V az 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_en":"AC voltage / AC voltage meters and generators Calibration – electrical quantities Direct measurement using a multimeter 40 Hz to 20 kHz 1 mV to 10 mV CMC 0,14 % 40 Hz to 20 kHz 10 mV to 10 V CMC 0,034 % 40 Hz to 20 kHz 10 V to 100 V CMC 0,040 % 40 Hz to 20 kHz 100 V to 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","search_zh":"交流电压 / 交流电压测量仪器和发生器 校准 – 电学量 用万用表直接测量 40 Hz 至 20 kHz 1 mV 至 10 mV CMC 0,14 % 40 Hz 至 20 kHz 10 mV 至 10 V CMC 0,034 % 40 Hz 至 20 kHz 10 V 至 100 V CMC 0,040 % 40 Hz 至 20 kHz 100 V 至 1000 V CMC 0,080 % J 62.03.E02.0, J 62.03.E09.0, J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec029158014b7c4b7c8db491","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 10 µA do 220 µA","cmc":"0,026 %"},{"name":"40 Hz do 1 kHz","range":"od 220 µA do 22 mA","cmc":"0,017 %"},{"name":"40 Hz do 1 kHz","range":"od 22 mA do 220 mA","cmc":"0,016 %"},{"name":"40 Hz do 1 kHz","range":"od 220 mA do 2,2 A","cmc":"0,033 %"},{"name":"40 Hz do 1 kHz","range":"od 2,2 A do 20 A","cmc":"0,11 %"},{"name":"50 Hz do 1 kHz","range":"od 20 A do 120 A","cmc":"0,11 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"10 µA to 220 µA","cmc":"0,026 %"},{"name":"40 Hz to 1 kHz","range":"220 µA to 22 mA","cmc":"0,017 %"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"0,016 %"},{"name":"40 Hz to 1 kHz","range":"220 mA to 2,2 A","cmc":"0,033 %"},{"name":"40 Hz to 1 kHz","range":"2,2 A to 20 A","cmc":"0,11 %"},{"name":"50 Hz to 1 kHz","range":"20 A to 120 A","cmc":"0,11 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"10 µA 至 220 µA","cmc":"0,026 %"},{"name":"40 Hz 至 1 kHz","range":"220 µA 至 22 mA","cmc":"0,017 %"},{"name":"40 Hz 至 1 kHz","range":"22 mA 至 220 mA","cmc":"0,016 %"},{"name":"40 Hz 至 1 kHz","range":"220 mA 至 2,2 A","cmc":"0,033 %"},{"name":"40 Hz 至 1 kHz","range":"2,2 A 至 20 A","cmc":"0,11 %"},{"name":"50 Hz 至 1 kHz","range":"20 A 至 120 A","cmc":"0,11 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"10 µA až 220 µA","cmc":"0,026 %"},{"name":"40 Hz až 1 kHz","range":"220 µA až 22 mA","cmc":"0,017 %"},{"name":"40 Hz až 1 kHz","range":"22 mA až 220 mA","cmc":"0,016 %"},{"name":"40 Hz až 1 kHz","range":"220 mA až 2,2 A","cmc":"0,033 %"},{"name":"40 Hz až 1 kHz","range":"2,2 A až 20 A","cmc":"0,11 %"},{"name":"50 Hz až 1 kHz","range":"20 A až 120 A","cmc":"0,11 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 10 µA do 220 µA CMC 0,026 %\n40 Hz do 1 kHz od 220 µA do 22 mA CMC 0,017 %\n40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,016 %\n40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,033 %\n40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,11 %\n50 Hz do 1 kHz od 20 A do 120 A CMC 0,11 %\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 40 Hz do 1 kHz od 10 µA do 220 µA CMC 0,026 % 40 Hz do 1 kHz od 220 µA do 22 mA CMC 0,017 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,016 % 40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,033 % 40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,11 % 50 Hz do 1 kHz od 20 A do 120 A CMC 0,11 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 40 Hz až 1 kHz 10 µA až 220 µA CMC 0,026 % 40 Hz až 1 kHz 220 µA až 22 mA CMC 0,017 % 40 Hz až 1 kHz 22 mA až 220 mA CMC 0,016 % 40 Hz až 1 kHz 220 mA až 2,2 A CMC 0,033 % 40 Hz až 1 kHz 2,2 A až 20 A CMC 0,11 % 50 Hz až 1 kHz 20 A až 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 40 Hz do 1 kHz od 10 µA do 220 µA CMC 0,026 % 40 Hz do 1 kHz od 220 µA do 22 mA CMC 0,017 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,016 % 40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,033 % 40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,11 % 50 Hz do 1 kHz od 20 A do 120 A CMC 0,11 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny Prime generovani kalibratorem 40 Hz az 1 kHz 10 µA az 220 µA CMC 0,026 % 40 Hz az 1 kHz 220 µA az 22 mA CMC 0,017 % 40 Hz az 1 kHz 22 mA az 220 mA CMC 0,016 % 40 Hz az 1 kHz 220 mA az 2,2 A CMC 0,033 % 40 Hz az 1 kHz 2,2 A az 20 A CMC 0,11 % 50 Hz az 1 kHz 20 A az 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities Direct generation with a calibrator 40 Hz to 1 kHz 10 µA to 220 µA CMC 0,026 % 40 Hz to 1 kHz 220 µA to 22 mA CMC 0,017 % 40 Hz to 1 kHz 22 mA to 220 mA CMC 0,016 % 40 Hz to 1 kHz 220 mA to 2,2 A CMC 0,033 % 40 Hz to 1 kHz 2,2 A to 20 A CMC 0,11 % 50 Hz to 1 kHz 20 A to 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 用校准器直接产生 40 Hz 至 1 kHz 10 µA 至 220 µA CMC 0,026 % 40 Hz 至 1 kHz 220 µA 至 22 mA CMC 0,017 % 40 Hz 至 1 kHz 22 mA 至 220 mA CMC 0,016 % 40 Hz 至 1 kHz 220 mA 至 2,2 A CMC 0,033 % 40 Hz 至 1 kHz 2,2 A 至 20 A CMC 0,11 % 50 Hz 至 1 kHz 20 A 至 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f976055edc072cc54f88b813","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 10 µA do 220 µA","cmc":"0,026 %"},{"name":"40 Hz do 1 kHz","range":"od 220 µA do 22 mA","cmc":"0,017 %"},{"name":"40 Hz do 1 kHz","range":"od 22 mA do 220 mA","cmc":"0,016 %"},{"name":"40 Hz do 1 kHz","range":"od 220 mA do 2,2 A","cmc":"0,033 %"},{"name":"40 Hz do 1 kHz","range":"od 2,2 A do 20 A","cmc":"0,11 %"},{"name":"50 Hz do 1 kHz","range":"od 20 A do 120 A","cmc":"0,11 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"10 µA to 220 µA","cmc":"0,026 %"},{"name":"40 Hz to 1 kHz","range":"220 µA to 22 mA","cmc":"0,017 %"},{"name":"40 Hz to 1 kHz","range":"22 mA to 220 mA","cmc":"0,016 %"},{"name":"40 Hz to 1 kHz","range":"220 mA to 2,2 A","cmc":"0,033 %"},{"name":"40 Hz to 1 kHz","range":"2,2 A to 20 A","cmc":"0,11 %"},{"name":"50 Hz to 1 kHz","range":"20 A to 120 A","cmc":"0,11 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"10 µA 至 220 µA","cmc":"0,026 %"},{"name":"40 Hz 至 1 kHz","range":"220 µA 至 22 mA","cmc":"0,017 %"},{"name":"40 Hz 至 1 kHz","range":"22 mA 至 220 mA","cmc":"0,016 %"},{"name":"40 Hz 至 1 kHz","range":"220 mA 至 2,2 A","cmc":"0,033 %"},{"name":"40 Hz 至 1 kHz","range":"2,2 A 至 20 A","cmc":"0,11 %"},{"name":"50 Hz 至 1 kHz","range":"20 A 至 120 A","cmc":"0,11 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"10 µA až 220 µA","cmc":"0,026 %"},{"name":"40 Hz až 1 kHz","range":"220 µA až 22 mA","cmc":"0,017 %"},{"name":"40 Hz až 1 kHz","range":"22 mA až 220 mA","cmc":"0,016 %"},{"name":"40 Hz až 1 kHz","range":"220 mA až 2,2 A","cmc":"0,033 %"},{"name":"40 Hz až 1 kHz","range":"2,2 A až 20 A","cmc":"0,11 %"},{"name":"50 Hz až 1 kHz","range":"20 A až 120 A","cmc":"0,11 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 10 µA do 220 µA CMC 0,026 %\n40 Hz do 1 kHz od 220 µA do 22 mA CMC 0,017 %\n40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,016 %\n40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,033 %\n40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,11 %\n50 Hz do 1 kHz od 20 A do 120 A CMC 0,11 %\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 40 Hz do 1 kHz od 10 µA do 220 µA CMC 0,026 % 40 Hz do 1 kHz od 220 µA do 22 mA CMC 0,017 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,016 % 40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,033 % 40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,11 % 50 Hz do 1 kHz od 20 A do 120 A CMC 0,11 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny Přímé generování kalibrátorem 40 Hz až 1 kHz 10 µA až 220 µA CMC 0,026 % 40 Hz až 1 kHz 220 µA až 22 mA CMC 0,017 % 40 Hz až 1 kHz 22 mA až 220 mA CMC 0,016 % 40 Hz až 1 kHz 220 mA až 2,2 A CMC 0,033 % 40 Hz až 1 kHz 2,2 A až 20 A CMC 0,11 % 50 Hz až 1 kHz 20 A až 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 40 Hz do 1 kHz od 10 µA do 220 µA CMC 0,026 % 40 Hz do 1 kHz od 220 µA do 22 mA CMC 0,017 % 40 Hz do 1 kHz od 22 mA do 220 mA CMC 0,016 % 40 Hz do 1 kHz od 220 mA do 2,2 A CMC 0,033 % 40 Hz do 1 kHz od 2,2 A do 20 A CMC 0,11 % 50 Hz do 1 kHz od 20 A do 120 A CMC 0,11 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny Prime generovani kalibratorem 40 Hz az 1 kHz 10 µA az 220 µA CMC 0,026 % 40 Hz az 1 kHz 220 µA az 22 mA CMC 0,017 % 40 Hz az 1 kHz 22 mA az 220 mA CMC 0,016 % 40 Hz az 1 kHz 220 mA az 2,2 A CMC 0,033 % 40 Hz az 1 kHz 2,2 A az 20 A CMC 0,11 % 50 Hz az 1 kHz 20 A az 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities Direct generation with a calibrator 40 Hz to 1 kHz 10 µA to 220 µA CMC 0,026 % 40 Hz to 1 kHz 220 µA to 22 mA CMC 0,017 % 40 Hz to 1 kHz 22 mA to 220 mA CMC 0,016 % 40 Hz to 1 kHz 220 mA to 2,2 A CMC 0,033 % 40 Hz to 1 kHz 2,2 A to 20 A CMC 0,11 % 50 Hz to 1 kHz 20 A to 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 用校准器直接产生 40 Hz 至 1 kHz 10 µA 至 220 µA CMC 0,026 % 40 Hz 至 1 kHz 220 µA 至 22 mA CMC 0,017 % 40 Hz 至 1 kHz 22 mA 至 220 mA CMC 0,016 % 40 Hz 至 1 kHz 220 mA 至 2,2 A CMC 0,033 % 40 Hz 至 1 kHz 2,2 A 至 20 A CMC 0,11 % 50 Hz 至 1 kHz 20 A 至 120 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b351304217f183b5caf67170","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 120 A do 1000 A","cmc":"0,67 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"120 A to 1000 A","cmc":"0,67 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"120 A 至 1000 A","cmc":"0,67 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"120 A až 1000 A","cmc":"0,67 %"}],"technique":"Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","technique_en":"Calibrator generation with current simulation using a current coil","technique_zh":"用校准器借助电流线圈模拟电流产生","technique_cs":"Generování kalibrátorem se simulací proudu pomocí proudové cívky","techniques":["Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej"],"techniques_en":["Calibrator generation with current simulation using a current coil"],"techniques_zh":["用校准器借助电流线圈模拟电流产生"],"techniques_cs":["Generování kalibrátorem se simulací proudu pomocí proudové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n45 Hz do 65 Hz od 120 A do 1000 A CMC 0,67 %\nGenerowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej 45 Hz do 65 Hz od 120 A do 1000 A CMC 0,67 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny Generování kalibrátorem se simulací proudu pomocí proudové cívky 45 Hz až 65 Hz 120 A až 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem z symulacja pradu za pomoca cewki pradowej 45 Hz do 65 Hz od 120 A do 1000 A CMC 0,67 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny Generovani kalibratorem se simulaci proudu pomoci proudove civky 45 Hz az 65 Hz 120 A az 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities Calibrator generation with current simulation using a current coil 45 Hz to 65 Hz 120 A to 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 用校准器借助电流线圈模拟电流产生 45 Hz 至 65 Hz 120 A 至 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dc8e3693639575dc34c9d442","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 65 Hz","range":"od 120 A do 1000 A","cmc":"0,67 %"}],"parameters_en":[{"name":"45 Hz to 65 Hz","range":"120 A to 1000 A","cmc":"0,67 %"}],"parameters_zh":[{"name":"45 Hz 至 65 Hz","range":"120 A 至 1000 A","cmc":"0,67 %"}],"parameters_cs":[{"name":"45 Hz až 65 Hz","range":"120 A až 1000 A","cmc":"0,67 %"}],"technique":"Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","technique_en":"Calibrator generation with current simulation using a current coil","technique_zh":"用校准器借助电流线圈模拟电流产生","technique_cs":"Generování kalibrátorem se simulací proudu pomocí proudové cívky","techniques":["Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej"],"techniques_en":["Calibrator generation with current simulation using a current coil"],"techniques_zh":["用校准器借助电流线圈模拟电流产生"],"techniques_cs":["Generování kalibrátorem se simulací proudu pomocí proudové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n45 Hz do 65 Hz od 120 A do 1000 A CMC 0,67 %\nGenerowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej 45 Hz do 65 Hz od 120 A do 1000 A CMC 0,67 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny Generování kalibrátorem se simulací proudu pomocí proudové cívky 45 Hz až 65 Hz 120 A až 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem z symulacja pradu za pomoca cewki pradowej 45 Hz do 65 Hz od 120 A do 1000 A CMC 0,67 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny Generovani kalibratorem se simulaci proudu pomoci proudove civky 45 Hz az 65 Hz 120 A az 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities Calibrator generation with current simulation using a current coil 45 Hz to 65 Hz 120 A to 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 用校准器借助电流线圈模拟电流产生 45 Hz 至 65 Hz 120 A 至 1000 A CMC 0,67 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"62c9a671ff826c4a024f123a","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 5 kHz","range":"od 10 µA do 100 µA","cmc":"0,11 %"},{"name":"45 Hz do 5 kHz","range":"od 100 µA do 100 mA","cmc":"0,092 %"},{"name":"45 Hz do 5 kHz","range":"od 100 mA do 1 A","cmc":"0,11 %"}],"parameters_en":[{"name":"45 Hz to 5 kHz","range":"10 µA to 100 µA","cmc":"0,11 %"},{"name":"45 Hz to 5 kHz","range":"100 µA to 100 mA","cmc":"0,092 %"},{"name":"45 Hz to 5 kHz","range":"100 mA to 1 A","cmc":"0,11 %"}],"parameters_zh":[{"name":"45 Hz 至 5 kHz","range":"10 µA 至 100 µA","cmc":"0,11 %"},{"name":"45 Hz 至 5 kHz","range":"100 µA 至 100 mA","cmc":"0,092 %"},{"name":"45 Hz 至 5 kHz","range":"100 mA 至 1 A","cmc":"0,11 %"}],"parameters_cs":[{"name":"45 Hz až 5 kHz","range":"10 µA až 100 µA","cmc":"0,11 %"},{"name":"45 Hz až 5 kHz","range":"100 µA až 100 mA","cmc":"0,092 %"},{"name":"45 Hz až 5 kHz","range":"100 mA až 1 A","cmc":"0,11 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 5 kHz od 10 µA do 100 µA CMC 0,11 %\n45 Hz do 5 kHz od 100 µA do 100 mA CMC 0,092 %\n45 Hz do 5 kHz od 100 mA do 1 A CMC 0,11 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 45 Hz do 5 kHz od 10 µA do 100 µA CMC 0,11 % 45 Hz do 5 kHz od 100 µA do 100 mA CMC 0,092 % 45 Hz do 5 kHz od 100 mA do 1 A CMC 0,11 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny Přímé měření multimetrem 45 Hz až 5 kHz 10 µA až 100 µA CMC 0,11 % 45 Hz až 5 kHz 100 µA až 100 mA CMC 0,092 % 45 Hz až 5 kHz 100 mA až 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 45 Hz do 5 kHz od 10 µA do 100 µA CMC 0,11 % 45 Hz do 5 kHz od 100 µA do 100 mA CMC 0,092 % 45 Hz do 5 kHz od 100 mA do 1 A CMC 0,11 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem 45 Hz az 5 kHz 10 µA az 100 µA CMC 0,11 % 45 Hz az 5 kHz 100 µA az 100 mA CMC 0,092 % 45 Hz az 5 kHz 100 mA az 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities Direct measurement using a multimeter 45 Hz to 5 kHz 10 µA to 100 µA CMC 0,11 % 45 Hz to 5 kHz 100 µA to 100 mA CMC 0,092 % 45 Hz to 5 kHz 100 mA to 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 用万用表直接测量 45 Hz 至 5 kHz 10 µA 至 100 µA CMC 0,11 % 45 Hz 至 5 kHz 100 µA 至 100 mA CMC 0,092 % 45 Hz 至 5 kHz 100 mA 至 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3aeed38e31f8c245bdbdb39f","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"45 Hz do 5 kHz","range":"od 10 µA do 100 µA","cmc":"0,11 %"},{"name":"45 Hz do 5 kHz","range":"od 100 µA do 100 mA","cmc":"0,092 %"},{"name":"45 Hz do 5 kHz","range":"od 100 mA do 1 A","cmc":"0,11 %"}],"parameters_en":[{"name":"45 Hz to 5 kHz","range":"10 µA to 100 µA","cmc":"0,11 %"},{"name":"45 Hz to 5 kHz","range":"100 µA to 100 mA","cmc":"0,092 %"},{"name":"45 Hz to 5 kHz","range":"100 mA to 1 A","cmc":"0,11 %"}],"parameters_zh":[{"name":"45 Hz 至 5 kHz","range":"10 µA 至 100 µA","cmc":"0,11 %"},{"name":"45 Hz 至 5 kHz","range":"100 µA 至 100 mA","cmc":"0,092 %"},{"name":"45 Hz 至 5 kHz","range":"100 mA 至 1 A","cmc":"0,11 %"}],"parameters_cs":[{"name":"45 Hz až 5 kHz","range":"10 µA až 100 µA","cmc":"0,11 %"},{"name":"45 Hz až 5 kHz","range":"100 µA až 100 mA","cmc":"0,092 %"},{"name":"45 Hz až 5 kHz","range":"100 mA až 1 A","cmc":"0,11 %"}],"technique":"Pomiar bezpośredni multimetrem","technique_en":"Direct measurement using a multimeter","technique_zh":"用万用表直接测量","technique_cs":"Přímé měření multimetrem","techniques":["Pomiar bezpośredni multimetrem"],"techniques_en":["Direct measurement using a multimeter"],"techniques_zh":["用万用表直接测量"],"techniques_cs":["Přímé měření multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n45 Hz do 5 kHz od 10 µA do 100 µA CMC 0,11 %\n45 Hz do 5 kHz od 100 µA do 100 mA CMC 0,092 %\n45 Hz do 5 kHz od 100 mA do 1 A CMC 0,11 %\nPomiar bezpośredni multimetrem","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem 45 Hz do 5 kHz od 10 µA do 100 µA CMC 0,11 % 45 Hz do 5 kHz od 100 µA do 100 mA CMC 0,092 % 45 Hz do 5 kHz od 100 mA do 1 A CMC 0,11 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny Přímé měření multimetrem 45 Hz až 5 kHz 10 µA až 100 µA CMC 0,11 % 45 Hz až 5 kHz 100 µA až 100 mA CMC 0,092 % 45 Hz až 5 kHz 100 mA až 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem 45 Hz do 5 kHz od 10 µA do 100 µA CMC 0,11 % 45 Hz do 5 kHz od 100 µA do 100 mA CMC 0,092 % 45 Hz do 5 kHz od 100 mA do 1 A CMC 0,11 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny Prime mereni multimetrem 45 Hz az 5 kHz 10 µA az 100 µA CMC 0,11 % 45 Hz az 5 kHz 100 µA az 100 mA CMC 0,092 % 45 Hz az 5 kHz 100 mA az 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities Direct measurement using a multimeter 45 Hz to 5 kHz 10 µA to 100 µA CMC 0,11 % 45 Hz to 5 kHz 100 µA to 100 mA CMC 0,092 % 45 Hz to 5 kHz 100 mA to 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 用万用表直接测量 45 Hz 至 5 kHz 10 µA 至 100 µA CMC 0,11 % 45 Hz 至 5 kHz 100 µA 至 100 mA CMC 0,092 % 45 Hz 至 5 kHz 100 mA 至 1 A CMC 0,11 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"68c2517bc7807d6d709bcc68","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 1 kHz","range":"od 1 A do 100 A","cmc":"0,14 %"}],"parameters_en":[{"name":"50 Hz to 1 kHz","range":"1 A to 100 A","cmc":"0,14 %"}],"parameters_zh":[{"name":"50 Hz 至 1 kHz","range":"1 A 至 100 A","cmc":"0,14 %"}],"parameters_cs":[{"name":"50 Hz až 1 kHz","range":"1 A až 100 A","cmc":"0,14 %"}],"technique":"pomiar multimetrem na boczniku prądowym","technique_en":"measurement with a multimeter on a current shunt","technique_zh":"在电流分流器上用万用表测量","technique_cs":"měření multimetrem na proudovém bočníku","techniques":["pomiar multimetrem na boczniku prądowym"],"techniques_en":["measurement with a multimeter on a current shunt"],"techniques_zh":["在电流分流器上用万用表测量"],"techniques_cs":["měření multimetrem na proudovém bočníku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz do 1 kHz od 1 A do 100 A CMC 0,14 %\npomiar multimetrem na boczniku prądowym","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne pomiar multimetrem na boczniku prądowym 50 Hz do 1 kHz od 1 A do 100 A CMC 0,14 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny měření multimetrem na proudovém bočníku 50 Hz až 1 kHz 1 A až 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne pomiar multimetrem na boczniku pradowym 50 Hz do 1 kHz od 1 A do 100 A CMC 0,14 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny mereni multimetrem na proudovem bocniku 50 Hz az 1 kHz 1 A az 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities measurement with a multimeter on a current shunt 50 Hz to 1 kHz 1 A to 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 在电流分流器上用万用表测量 50 Hz 至 1 kHz 1 A 至 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d780c0e2b85bbb76f558ad91","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"5","test_object":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego","test_object_en":"AC current / AC current meters and generators","test_object_zh":"交流电流 / 交流电流测量仪器和发生器","test_object_cs":"Střídavý proud / měřidla a generátory střídavého proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz do 1 kHz","range":"od 1 A do 100 A","cmc":"0,14 %"}],"parameters_en":[{"name":"50 Hz to 1 kHz","range":"1 A to 100 A","cmc":"0,14 %"}],"parameters_zh":[{"name":"50 Hz 至 1 kHz","range":"1 A 至 100 A","cmc":"0,14 %"}],"parameters_cs":[{"name":"50 Hz až 1 kHz","range":"1 A až 100 A","cmc":"0,14 %"}],"technique":"pomiar multimetrem na boczniku prądowym","technique_en":"measurement with a multimeter on a current shunt","technique_zh":"在电流分流器上用万用表测量","technique_cs":"měření multimetrem na proudovém bočníku","techniques":["pomiar multimetrem na boczniku prądowym"],"techniques_en":["measurement with a multimeter on a current shunt"],"techniques_zh":["在电流分流器上用万用表测量"],"techniques_cs":["měření multimetrem na proudovém bočníku"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz do 1 kHz od 1 A do 100 A CMC 0,14 %\npomiar multimetrem na boczniku prądowym","reference":"J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","norm_bases":["J 62.03.E04.0","J 62.03.E11.0","J 62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru i generatory prądu przemiennego Wzorcowanie – wielkości elektryczne pomiar multimetrem na boczniku prądowym 50 Hz do 1 kHz od 1 A do 100 A CMC 0,14 % Střídavý proud / měřidla a generátory střídavého proudu Kalibrace – elektrické veličiny měření multimetrem na proudovém bočníku 50 Hz až 1 kHz 1 A až 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0 Prad przemienny / przyrzady do pomiaru i generatory pradu przemiennego Wzorcowanie – wielkosci elektryczne pomiar multimetrem na boczniku pradowym 50 Hz do 1 kHz od 1 A do 100 A CMC 0,14 % Stridavy proud / meridla a generatory stridaveho proudu Kalibrace – elektricke veliciny mereni multimetrem na proudovem bocniku 50 Hz az 1 kHz 1 A az 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_en":"AC current / AC current meters and generators Calibration – electrical quantities measurement with a multimeter on a current shunt 50 Hz to 1 kHz 1 A to 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","search_zh":"交流电流 / 交流电流测量仪器和发生器 校准 – 电学量 在电流分流器上用万用表测量 50 Hz 至 1 kHz 1 A 至 100 A CMC 0,14 % J 62.03.E04.0 J 62.03.E11.0 J 62.03.E15.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b4ef8dd558409d774ccac5ea","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"6","test_object":"Moc elektryczna / mierniki mocy elektrycznej (50 Hz, do 740 V)","test_object_en":"Electrical power / power meters (50 Hz, up to 740 V)","test_object_zh":"电功率 / 电功率测量仪器（50 Hz，最高 740 V）","test_object_cs":"Elektrický výkon / měřidla elektrického výkonu (50 Hz, do 740 V)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"(0,011 do 11) A, cos φ = 1","range":"od 0,1 kW do 37 kW","cmc":"0,058 %"},{"name":"(0,011 do 11) A, cos φ = 0,8 do 0,9","range":"od 0,1 kW do 37 kW","cmc":"0,093 %"},{"name":"(0,011 do 11) A, cos φ = 0,1 do 0,7","range":"od 0,1 kW do 37 kW","cmc":"0,14 %"},{"name":"(11 do 50) A, cos φ = 1","range":"od 0,1 kW do 37 kW","cmc":"0,075 %"},{"name":"(11 do 50) A, cos φ = 0,8 do 0,9","range":"od 0,1 kW do 37 kW","cmc":"0,11 %"},{"name":"(11 do 50) A, cos φ = 0,1 do 0,7","range":"od 0,1 kW do 37 kW","cmc":"0,16 %"}],"parameters_en":[{"name":"(0.011 to 11) A, cos φ = 1","range":"0,1 kW to 37 kW","cmc":"0,058 %"},{"name":"(0.011 to 11) A, cos φ = 0.8 to 0.9","range":"0,1 kW to 37 kW","cmc":"0,093 %"},{"name":"(0.011 to 11) A, cos φ = 0.1 to 0.7","range":"0,1 kW to 37 kW","cmc":"0,14 %"},{"name":"(11 to 50) A, cos φ = 1","range":"0,1 kW to 37 kW","cmc":"0,075 %"},{"name":"(11 to 50) A, cos φ = 0.8 to 0.9","range":"0,1 kW to 37 kW","cmc":"0,11 %"},{"name":"(11 to 50) A, cos φ = 0.1 to 0.7","range":"0,1 kW to 37 kW","cmc":"0,16 %"}],"parameters_zh":[{"name":"(0,011 至 11) A，cos φ = 1","range":"0,1 kW 至 37 kW","cmc":"0,058 %"},{"name":"(0,011 至 11) A，cos φ = 0,8 至 0,9","range":"0,1 kW 至 37 kW","cmc":"0,093 %"},{"name":"(0,011 至 11) A，cos φ = 0,1 至 0,7","range":"0,1 kW 至 37 kW","cmc":"0,14 %"},{"name":"(11 至 50) A，cos φ = 1","range":"0,1 kW 至 37 kW","cmc":"0,075 %"},{"name":"(11 至 50) A，cos φ = 0,8 至 0,9","range":"0,1 kW 至 37 kW","cmc":"0,11 %"},{"name":"(11 至 50) A，cos φ = 0,1 至 0,7","range":"0,1 kW 至 37 kW","cmc":"0,16 %"}],"parameters_cs":[{"name":"(0,011 až 11) A, cos φ = 1","range":"0,1 kW až 37 kW","cmc":"0,058 %"},{"name":"(0,011 až 11) A, cos φ = 0,8 až 0,9","range":"0,1 kW až 37 kW","cmc":"0,093 %"},{"name":"(0,011 až 11) A, cos φ = 0,1 až 0,7","range":"0,1 kW až 37 kW","cmc":"0,14 %"},{"name":"(11 až 50) A, cos φ = 1","range":"0,1 kW až 37 kW","cmc":"0,075 %"},{"name":"(11 až 50) A, cos φ = 0,8 až 0,9","range":"0,1 kW až 37 kW","cmc":"0,11 %"},{"name":"(11 až 50) A, cos φ = 0,1 až 0,7","range":"0,1 kW až 37 kW","cmc":"0,16 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n(0,011 do 11) A, cos φ = 1 od 0,1 kW do 37 kW CMC 0,058 %\n(0,011 do 11) A, cos φ = 0,8 do 0,9 od 0,1 kW do 37 kW CMC 0,093 %\n(0,011 do 11) A, cos φ = 0,1 do 0,7 od 0,1 kW do 37 kW CMC 0,14 %\n(11 do 50) A, cos φ = 1 od 0,1 kW do 37 kW CMC 0,075 %\n(11 do 50) A, cos φ = 0,8 do 0,9 od 0,1 kW do 37 kW CMC 0,11 %\n(11 do 50) A, cos φ = 0,1 do 0,7 od 0,1 kW do 37 kW CMC 0,16 %\nBezpośrednie generowanie kalibratorem","reference":"J 62.03.E14.0","norm_bases":["J 62.03.E14.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc elektryczna / mierniki mocy elektrycznej (50 Hz, do 740 V) Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem (0,011 do 11) A, cos φ = 1 od 0,1 kW do 37 kW CMC 0,058 % (0,011 do 11) A, cos φ = 0,8 do 0,9 od 0,1 kW do 37 kW CMC 0,093 % (0,011 do 11) A, cos φ = 0,1 do 0,7 od 0,1 kW do 37 kW CMC 0,14 % (11 do 50) A, cos φ = 1 od 0,1 kW do 37 kW CMC 0,075 % (11 do 50) A, cos φ = 0,8 do 0,9 od 0,1 kW do 37 kW CMC 0,11 % (11 do 50) A, cos φ = 0,1 do 0,7 od 0,1 kW do 37 kW CMC 0,16 % Elektrický výkon / měřidla elektrického výkonu (50 Hz, do 740 V) Kalibrace – elektrické veličiny Přímé generování kalibrátorem (0,011 až 11) A, cos φ = 1 0,1 kW až 37 kW CMC 0,058 % (0,011 až 11) A, cos φ = 0,8 až 0,9 0,1 kW až 37 kW CMC 0,093 % (0,011 až 11) A, cos φ = 0,1 až 0,7 0,1 kW až 37 kW CMC 0,14 % (11 až 50) A, cos φ = 1 0,1 kW až 37 kW CMC 0,075 % (11 až 50) A, cos φ = 0,8 až 0,9 0,1 kW až 37 kW CMC 0,11 % (11 až 50) A, cos φ = 0,1 až 0,7 0,1 kW až 37 kW CMC 0,16 % J 62.03.E14.0 Moc elektryczna / mierniki mocy elektrycznej (50 Hz, do 740 V) Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem (0,011 do 11) A, cos φ = 1 od 0,1 kW do 37 kW CMC 0,058 % (0,011 do 11) A, cos φ = 0,8 do 0,9 od 0,1 kW do 37 kW CMC 0,093 % (0,011 do 11) A, cos φ = 0,1 do 0,7 od 0,1 kW do 37 kW CMC 0,14 % (11 do 50) A, cos φ = 1 od 0,1 kW do 37 kW CMC 0,075 % (11 do 50) A, cos φ = 0,8 do 0,9 od 0,1 kW do 37 kW CMC 0,11 % (11 do 50) A, cos φ = 0,1 do 0,7 od 0,1 kW do 37 kW CMC 0,16 % Elektricky vykon / meridla elektrickeho vykonu (50 Hz, do 740 V) Kalibrace – elektricke veliciny Prime generovani kalibratorem (0,011 az 11) A, cos φ = 1 0,1 kW az 37 kW CMC 0,058 % (0,011 az 11) A, cos φ = 0,8 az 0,9 0,1 kW az 37 kW CMC 0,093 % (0,011 az 11) A, cos φ = 0,1 az 0,7 0,1 kW az 37 kW CMC 0,14 % (11 az 50) A, cos φ = 1 0,1 kW az 37 kW CMC 0,075 % (11 az 50) A, cos φ = 0,8 az 0,9 0,1 kW az 37 kW CMC 0,11 % (11 az 50) A, cos φ = 0,1 az 0,7 0,1 kW az 37 kW CMC 0,16 % J 62.03.E14.0","search_en":"Electrical power / power meters (50 Hz, up to 740 V) Calibration – electrical quantities Direct generation with a calibrator (0.011 to 11) A, cos φ = 1 0,1 kW to 37 kW CMC 0,058 % (0.011 to 11) A, cos φ = 0.8 to 0.9 0,1 kW to 37 kW CMC 0,093 % (0.011 to 11) A, cos φ = 0.1 to 0.7 0,1 kW to 37 kW CMC 0,14 % (11 to 50) A, cos φ = 1 0,1 kW to 37 kW CMC 0,075 % (11 to 50) A, cos φ = 0.8 to 0.9 0,1 kW to 37 kW CMC 0,11 % (11 to 50) A, cos φ = 0.1 to 0.7 0,1 kW to 37 kW CMC 0,16 % J 62.03.E14.0","search_zh":"电功率 / 电功率测量仪器（50 Hz，最高 740 V） 校准 – 电学量 用校准器直接产生 (0,011 至 11) A，cos φ = 1 0,1 kW 至 37 kW CMC 0,058 % (0,011 至 11) A，cos φ = 0,8 至 0,9 0,1 kW 至 37 kW CMC 0,093 % (0,011 至 11) A，cos φ = 0,1 至 0,7 0,1 kW 至 37 kW CMC 0,14 % (11 至 50) A，cos φ = 1 0,1 kW 至 37 kW CMC 0,075 % (11 至 50) A，cos φ = 0,8 至 0,9 0,1 kW 至 37 kW CMC 0,11 % (11 至 50) A，cos φ = 0,1 至 0,7 0,1 kW 至 37 kW CMC 0,16 % J 62.03.E14.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"07999c7f77af70f302e66f34","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"6","test_object":"Moc elektryczna / mierniki mocy elektrycznej (50 Hz, do 740 V)","test_object_en":"Electrical power / power meters (50 Hz, up to 740 V)","test_object_zh":"电功率 / 电功率测量仪器（50 Hz，最高 740 V）","test_object_cs":"Elektrický výkon / měřidla elektrického výkonu (50 Hz, do 740 V)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"(50 do 1000) A, cos φ = 1","range":"od 37 kW do 740 kW","cmc":"0,76 %"},{"name":"(50 do 1000) A, cos φ = 0,8 do 0,9","range":"od 37 kW do 740 kW","cmc":"0,77 %"},{"name":"(50 do 1000) A, cos φ = 0,1 do 0,7","range":"od 37 kW do 740 kW","cmc":"0,78 %"}],"parameters_en":[{"name":"(50 to 1000) A, cos φ = 1","range":"37 kW to 740 kW","cmc":"0,76 %"},{"name":"(50 to 1000) A, cos φ = 0.8 to 0.9","range":"37 kW to 740 kW","cmc":"0,77 %"},{"name":"(50 to 1000) A, cos φ = 0.1 to 0.7","range":"37 kW to 740 kW","cmc":"0,78 %"}],"parameters_zh":[{"name":"(50 至 1000) A，cos φ = 1","range":"37 kW 至 740 kW","cmc":"0,76 %"},{"name":"(50 至 1000) A，cos φ = 0,8 至 0,9","range":"37 kW 至 740 kW","cmc":"0,77 %"},{"name":"(50 至 1000) A，cos φ = 0,1 至 0,7","range":"37 kW 至 740 kW","cmc":"0,78 %"}],"parameters_cs":[{"name":"(50 až 1000) A, cos φ = 1","range":"37 kW až 740 kW","cmc":"0,76 %"},{"name":"(50 až 1000) A, cos φ = 0,8 až 0,9","range":"37 kW až 740 kW","cmc":"0,77 %"},{"name":"(50 až 1000) A, cos φ = 0,1 až 0,7","range":"37 kW až 740 kW","cmc":"0,78 %"}],"technique":"Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","technique_en":"Calibrator generation with current simulation using a current coil","technique_zh":"用校准器借助电流线圈模拟电流产生","technique_cs":"Generování kalibrátorem se simulací proudu pomocí proudové cívky","techniques":["Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej"],"techniques_en":["Calibrator generation with current simulation using a current coil"],"techniques_zh":["用校准器借助电流线圈模拟电流产生"],"techniques_cs":["Generování kalibrátorem se simulací proudu pomocí proudové cívky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n(50 do 1000) A, cos φ = 1 od 37 kW do 740 kW CMC 0,76 %\n(50 do 1000) A, cos φ = 0,8 do 0,9 od 37 kW do 740 kW CMC 0,77 %\n(50 do 1000) A, cos φ = 0,1 do 0,7 od 37 kW do 740 kW CMC 0,78 %\nGenerowanie kalibratorem z symulacją prądu za pomocą cewki prądowej","reference":"J 62.03.E14.0","norm_bases":["J 62.03.E14.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Moc elektryczna / mierniki mocy elektrycznej (50 Hz, do 740 V) Wzorcowanie – wielkości elektryczne Generowanie kalibratorem z symulacją prądu za pomocą cewki prądowej (50 do 1000) A, cos φ = 1 od 37 kW do 740 kW CMC 0,76 % (50 do 1000) A, cos φ = 0,8 do 0,9 od 37 kW do 740 kW CMC 0,77 % (50 do 1000) A, cos φ = 0,1 do 0,7 od 37 kW do 740 kW CMC 0,78 % Elektrický výkon / měřidla elektrického výkonu (50 Hz, do 740 V) Kalibrace – elektrické veličiny Generování kalibrátorem se simulací proudu pomocí proudové cívky (50 až 1000) A, cos φ = 1 37 kW až 740 kW CMC 0,76 % (50 až 1000) A, cos φ = 0,8 až 0,9 37 kW až 740 kW CMC 0,77 % (50 až 1000) A, cos φ = 0,1 až 0,7 37 kW až 740 kW CMC 0,78 % J 62.03.E14.0 Moc elektryczna / mierniki mocy elektrycznej (50 Hz, do 740 V) Wzorcowanie – wielkosci elektryczne Generowanie kalibratorem z symulacja pradu za pomoca cewki pradowej (50 do 1000) A, cos φ = 1 od 37 kW do 740 kW CMC 0,76 % (50 do 1000) A, cos φ = 0,8 do 0,9 od 37 kW do 740 kW CMC 0,77 % (50 do 1000) A, cos φ = 0,1 do 0,7 od 37 kW do 740 kW CMC 0,78 % Elektricky vykon / meridla elektrickeho vykonu (50 Hz, do 740 V) Kalibrace – elektricke veliciny Generovani kalibratorem se simulaci proudu pomoci proudove civky (50 az 1000) A, cos φ = 1 37 kW az 740 kW CMC 0,76 % (50 az 1000) A, cos φ = 0,8 az 0,9 37 kW az 740 kW CMC 0,77 % (50 az 1000) A, cos φ = 0,1 az 0,7 37 kW az 740 kW CMC 0,78 % J 62.03.E14.0","search_en":"Electrical power / power meters (50 Hz, up to 740 V) Calibration – electrical quantities Calibrator generation with current simulation using a current coil (50 to 1000) A, cos φ = 1 37 kW to 740 kW CMC 0,76 % (50 to 1000) A, cos φ = 0.8 to 0.9 37 kW to 740 kW CMC 0,77 % (50 to 1000) A, cos φ = 0.1 to 0.7 37 kW to 740 kW CMC 0,78 % J 62.03.E14.0","search_zh":"电功率 / 电功率测量仪器（50 Hz，最高 740 V） 校准 – 电学量 用校准器借助电流线圈模拟电流产生 (50 至 1000) A，cos φ = 1 37 kW 至 740 kW CMC 0,76 % (50 至 1000) A，cos φ = 0,8 至 0,9 37 kW 至 740 kW CMC 0,77 % (50 至 1000) A，cos φ = 0,1 至 0,7 37 kW 至 740 kW CMC 0,78 % J 62.03.E14.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f240d32bfd0eb64af19a4d92","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"7","test_object":"pH / pehametry (tylko część elektryczna przyrządu)","test_object_en":"pH / pH meters (only the electrical part of the instrument)","test_object_zh":"pH / pH 计（仅仪器电气部分）","test_object_cs":"pH / měřidla pH (pouze elektrická část přístroje)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 do 14","cmc":"0,001"}],"parameters_en":[{"name":"","range":"0 to 14","cmc":"0,001"}],"parameters_zh":[{"name":"","range":"0 至 14","cmc":"0,001"}],"parameters_cs":[{"name":"","range":"0 až 14","cmc":"0,001"}],"technique":"Symulacja pH napięciem","technique_en":"Simulation of pH using voltage","technique_zh":"用电压模拟 pH","technique_cs":"Simulace pH napětím","techniques":["Symulacja pH napięciem"],"techniques_en":["Simulation of pH using voltage"],"techniques_zh":["用电压模拟 pH"],"techniques_cs":["Simulace pH napětím"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 0 do 14 CMC 0,001\nSymulacja pH napięciem","reference":"J 62.03.Q01.0","norm_bases":["J 62.03.Q01.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"pH / pehametry (tylko część elektryczna przyrządu) Wzorcowanie – wielkości elektryczne Symulacja pH napięciem od 0 do 14 CMC 0,001 pH / měřidla pH (pouze elektrická část přístroje) Kalibrace – elektrické veličiny Simulace pH napětím 0 až 14 CMC 0,001 J 62.03.Q01.0 pH / pehametry (tylko czesc elektryczna przyrzadu) Wzorcowanie – wielkosci elektryczne Symulacja pH napieciem od 0 do 14 CMC 0,001 pH / meridla pH (pouze elektricka cast pristroje) Kalibrace – elektricke veliciny Simulace pH napetim 0 az 14 CMC 0,001 J 62.03.Q01.0","search_en":"pH / pH meters (only the electrical part of the instrument) Calibration – electrical quantities Simulation of pH using voltage 0 to 14 CMC 0,001 J 62.03.Q01.0","search_zh":"pH / pH 计（仅仪器电气部分） 校准 – 电学量 用电压模拟 pH 0 至 14 CMC 0,001 J 62.03.Q01.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b3aab544a5b4457a28e3ef98","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"7","test_object":"pH / pehametry (tylko część elektryczna przyrządu)","test_object_en":"pH / pH meters (only the electrical part of the instrument)","test_object_zh":"pH / pH 计（仅仪器电气部分）","test_object_cs":"pH / měřidla pH (pouze elektrická část přístroje)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 do 14","cmc":"0,001"}],"parameters_en":[{"name":"","range":"0 to 14","cmc":"0,001"}],"parameters_zh":[{"name":"","range":"0 至 14","cmc":"0,001"}],"parameters_cs":[{"name":"","range":"0 až 14","cmc":"0,001"}],"technique":"Symulacja pH napięciem","technique_en":"Simulation of pH using voltage","technique_zh":"用电压模拟 pH","technique_cs":"Simulace pH napětím","techniques":["Symulacja pH napięciem"],"techniques_en":["Simulation of pH using voltage"],"techniques_zh":["用电压模拟 pH"],"techniques_cs":["Simulace pH napětím"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 0 do 14 CMC 0,001\nSymulacja pH napięciem","reference":"J 62.03.Q01.0","norm_bases":["J 62.03.Q01.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"pH / pehametry (tylko część elektryczna przyrządu) Wzorcowanie – wielkości elektryczne Symulacja pH napięciem od 0 do 14 CMC 0,001 pH / měřidla pH (pouze elektrická část přístroje) Kalibrace – elektrické veličiny Simulace pH napětím 0 až 14 CMC 0,001 J 62.03.Q01.0 pH / pehametry (tylko czesc elektryczna przyrzadu) Wzorcowanie – wielkosci elektryczne Symulacja pH napieciem od 0 do 14 CMC 0,001 pH / meridla pH (pouze elektricka cast pristroje) Kalibrace – elektricke veliciny Simulace pH napetim 0 az 14 CMC 0,001 J 62.03.Q01.0","search_en":"pH / pH meters (only the electrical part of the instrument) Calibration – electrical quantities Simulation of pH using voltage 0 to 14 CMC 0,001 J 62.03.Q01.0","search_zh":"pH / pH 计（仅仪器电气部分） 校准 – 电学量 用电压模拟 pH 0 至 14 CMC 0,001 J 62.03.Q01.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f5932898bf86e36c7719f1c1","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"8","test_object":"Przewodność / konduktometry (tylko część elektryczna przyrządu)","test_object_en":"Conductivity / conductivity meters (only the electrical part of the instrument)","test_object_zh":"电导率 / 电导率仪（仅仪器电气部分）","test_object_cs":"Vodivost / měřidla vodivosti (pouze elektrická část přístroje)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 µS do 1 µS","cmc":"0,024 %"},{"name":"","range":"od 1 µS do 10 µS","cmc":"0,012 %"},{"name":"","range":"od 10 µS do 100 mS","cmc":"0,012 %"},{"name":"","range":"od 100 mS do 500 mS","cmc":"0,058 %"}],"parameters_en":[{"name":"","range":"0,1 µS to 1 µS","cmc":"0,024 %"},{"name":"","range":"1 µS to 10 µS","cmc":"0,012 %"},{"name":"","range":"10 µS to 100 mS","cmc":"0,012 %"},{"name":"","range":"100 mS to 500 mS","cmc":"0,058 %"}],"parameters_zh":[{"name":"","range":"0,1 µS 至 1 µS","cmc":"0,024 %"},{"name":"","range":"1 µS 至 10 µS","cmc":"0,012 %"},{"name":"","range":"10 µS 至 100 mS","cmc":"0,012 %"},{"name":"","range":"100 mS 至 500 mS","cmc":"0,058 %"}],"parameters_cs":[{"name":"","range":"0,1 µS až 1 µS","cmc":"0,024 %"},{"name":"","range":"1 µS až 10 µS","cmc":"0,012 %"},{"name":"","range":"10 µS až 100 mS","cmc":"0,012 %"},{"name":"","range":"100 mS až 500 mS","cmc":"0,058 %"}],"technique":"Symulacja przewodności rezystancją","technique_en":"Simulation of conductivity using resistance","technique_zh":"用电阻模拟电导率","technique_cs":"Simulace vodivosti odporem","techniques":["Symulacja przewodności rezystancją"],"techniques_en":["Simulation of conductivity using resistance"],"techniques_zh":["用电阻模拟电导率"],"techniques_cs":["Simulace vodivosti odporem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,1 µS do 1 µS CMC 0,024 %\nod 1 µS do 10 µS CMC 0,012 %\nod 10 µS do 100 mS CMC 0,012 %\nod 100 mS do 500 mS CMC 0,058 %\nSymulacja przewodności rezystancją","reference":"J 62.03.Q02.0","norm_bases":["J 62.03.Q02.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przewodność / konduktometry (tylko część elektryczna przyrządu) Wzorcowanie – wielkości elektryczne Symulacja przewodności rezystancją od 0,1 µS do 1 µS CMC 0,024 % od 1 µS do 10 µS CMC 0,012 % od 10 µS do 100 mS CMC 0,012 % od 100 mS do 500 mS CMC 0,058 % Vodivost / měřidla vodivosti (pouze elektrická část přístroje) Kalibrace – elektrické veličiny Simulace vodivosti odporem 0,1 µS až 1 µS CMC 0,024 % 1 µS až 10 µS CMC 0,012 % 10 µS až 100 mS CMC 0,012 % 100 mS až 500 mS CMC 0,058 % J 62.03.Q02.0 Przewodnosc / konduktometry (tylko czesc elektryczna przyrzadu) Wzorcowanie – wielkosci elektryczne Symulacja przewodnosci rezystancja od 0,1 µS do 1 µS CMC 0,024 % od 1 µS do 10 µS CMC 0,012 % od 10 µS do 100 mS CMC 0,012 % od 100 mS do 500 mS CMC 0,058 % Vodivost / meridla vodivosti (pouze elektricka cast pristroje) Kalibrace – elektricke veliciny Simulace vodivosti odporem 0,1 µS az 1 µS CMC 0,024 % 1 µS az 10 µS CMC 0,012 % 10 µS az 100 mS CMC 0,012 % 100 mS az 500 mS CMC 0,058 % J 62.03.Q02.0","search_en":"Conductivity / conductivity meters (only the electrical part of the instrument) Calibration – electrical quantities Simulation of conductivity using resistance 0,1 µS to 1 µS CMC 0,024 % 1 µS to 10 µS CMC 0,012 % 10 µS to 100 mS CMC 0,012 % 100 mS to 500 mS CMC 0,058 % J 62.03.Q02.0","search_zh":"电导率 / 电导率仪（仅仪器电气部分） 校准 – 电学量 用电阻模拟电导率 0,1 µS 至 1 µS CMC 0,024 % 1 µS 至 10 µS CMC 0,012 % 10 µS 至 100 mS CMC 0,012 % 100 mS 至 500 mS CMC 0,058 % J 62.03.Q02.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"90bf54de28f90bc66df15f0a","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"8","test_object":"Przewodność / konduktometry (tylko część elektryczna przyrządu)","test_object_en":"Conductivity / conductivity meters (only the electrical part of the instrument)","test_object_zh":"电导率 / 电导率仪（仅仪器电气部分）","test_object_cs":"Vodivost / měřidla vodivosti (pouze elektrická část přístroje)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 µS do 1 µS","cmc":"0,024 %"},{"name":"","range":"od 1 µS do 10 µS","cmc":"0,012 %"},{"name":"","range":"od 10 µS do 100 mS","cmc":"0,012 %"},{"name":"","range":"od 100 mS do 500 mS","cmc":"0,058 %"}],"parameters_en":[{"name":"","range":"0,1 µS to 1 µS","cmc":"0,024 %"},{"name":"","range":"1 µS to 10 µS","cmc":"0,012 %"},{"name":"","range":"10 µS to 100 mS","cmc":"0,012 %"},{"name":"","range":"100 mS to 500 mS","cmc":"0,058 %"}],"parameters_zh":[{"name":"","range":"0,1 µS 至 1 µS","cmc":"0,024 %"},{"name":"","range":"1 µS 至 10 µS","cmc":"0,012 %"},{"name":"","range":"10 µS 至 100 mS","cmc":"0,012 %"},{"name":"","range":"100 mS 至 500 mS","cmc":"0,058 %"}],"parameters_cs":[{"name":"","range":"0,1 µS až 1 µS","cmc":"0,024 %"},{"name":"","range":"1 µS až 10 µS","cmc":"0,012 %"},{"name":"","range":"10 µS až 100 mS","cmc":"0,012 %"},{"name":"","range":"100 mS až 500 mS","cmc":"0,058 %"}],"technique":"Symulacja przewodności rezystancją","technique_en":"Simulation of conductivity using resistance","technique_zh":"用电阻模拟电导率","technique_cs":"Simulace vodivosti odporem","techniques":["Symulacja przewodności rezystancją"],"techniques_en":["Simulation of conductivity using resistance"],"techniques_zh":["用电阻模拟电导率"],"techniques_cs":["Simulace vodivosti odporem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,1 µS do 1 µS CMC 0,024 %\nod 1 µS do 10 µS CMC 0,012 %\nod 10 µS do 100 mS CMC 0,012 %\nod 100 mS do 500 mS CMC 0,058 %\nSymulacja przewodności rezystancją","reference":"J 62.03.Q02.0","norm_bases":["J 62.03.Q02.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przewodność / konduktometry (tylko część elektryczna przyrządu) Wzorcowanie – wielkości elektryczne Symulacja przewodności rezystancją od 0,1 µS do 1 µS CMC 0,024 % od 1 µS do 10 µS CMC 0,012 % od 10 µS do 100 mS CMC 0,012 % od 100 mS do 500 mS CMC 0,058 % Vodivost / měřidla vodivosti (pouze elektrická část přístroje) Kalibrace – elektrické veličiny Simulace vodivosti odporem 0,1 µS až 1 µS CMC 0,024 % 1 µS až 10 µS CMC 0,012 % 10 µS až 100 mS CMC 0,012 % 100 mS až 500 mS CMC 0,058 % J 62.03.Q02.0 Przewodnosc / konduktometry (tylko czesc elektryczna przyrzadu) Wzorcowanie – wielkosci elektryczne Symulacja przewodnosci rezystancja od 0,1 µS do 1 µS CMC 0,024 % od 1 µS do 10 µS CMC 0,012 % od 10 µS do 100 mS CMC 0,012 % od 100 mS do 500 mS CMC 0,058 % Vodivost / meridla vodivosti (pouze elektricka cast pristroje) Kalibrace – elektricke veliciny Simulace vodivosti odporem 0,1 µS az 1 µS CMC 0,024 % 1 µS az 10 µS CMC 0,012 % 10 µS az 100 mS CMC 0,012 % 100 mS az 500 mS CMC 0,058 % J 62.03.Q02.0","search_en":"Conductivity / conductivity meters (only the electrical part of the instrument) Calibration – electrical quantities Simulation of conductivity using resistance 0,1 µS to 1 µS CMC 0,024 % 1 µS to 10 µS CMC 0,012 % 10 µS to 100 mS CMC 0,012 % 100 mS to 500 mS CMC 0,058 % J 62.03.Q02.0","search_zh":"电导率 / 电导率仪（仅仪器电气部分） 校准 – 电学量 用电阻模拟电导率 0,1 µS 至 1 µS CMC 0,024 % 1 µS 至 10 µS CMC 0,012 % 10 µS 至 100 mS CMC 0,012 % 100 mS 至 500 mS CMC 0,058 % J 62.03.Q02.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b03ee4a6c8efb01eecc3c6fc","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"9","test_object":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury","test_object_en":"Measurement and simulation of temperature sensors / temperature gauges","test_object_zh":"温度传感器信号的测量和模拟 / 温度测量仪器","test_object_cs":"Měření a simulace signálů snímačů teploty / měřidla teploty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"OST","range":"od 0 Ω do 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"od 100 Ω do 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"od 400 Ω do 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"parameters_en":[{"name":"OST","range":"0 Ω to 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"100 Ω to 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"400 Ω to 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"parameters_zh":[{"name":"OST","range":"0 Ω 至 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"100 Ω 至 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"400 Ω 至 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"parameters_cs":[{"name":"OST","range":"0 Ω až 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"100 Ω až 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"400 Ω až 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"technique":"Bezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną","technique_en":"Direct resistance generation by a calibrator / resistance box","technique_zh":"用校准器 / 电阻箱直接产生电阻","technique_cs":"Přímé generování odporu kalibrátorem / odporovou dekádou","techniques":["Bezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną"],"techniques_en":["Direct resistance generation by a calibrator / resistance box"],"techniques_zh":["用校准器 / 电阻箱直接产生电阻"],"techniques_cs":["Přímé generování odporu kalibrátorem / odporovou dekádou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nOST od 0 Ω do 100 Ω CMC 20 mΩ\nOST od 100 Ω do 400 Ω CMC 0,01 % + 10 mΩ\nOST od 400 Ω do 4000 Ω CMC 0,015 % + 20 mΩ\nBezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną","reference":"J 62.03.T07","norm_bases":["J 62.03.T07"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną OST od 0 Ω do 100 Ω CMC 20 mΩ OST od 100 Ω do 400 Ω CMC 0,01 % + 10 mΩ OST od 400 Ω do 4000 Ω CMC 0,015 % + 20 mΩ Měření a simulace signálů snímačů teploty / měřidla teploty Kalibrace – elektrické veličiny Přímé generování odporu kalibrátorem / odporovou dekádou OST 0 Ω až 100 Ω CMC 20 mΩ OST 100 Ω až 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω až 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07 Pomiar i symulacja sygnalow czujnikow temperatury / przyrzady do pomiaru temperatury Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie rezystancji kalibratorem / dekada rezystancyjna OST od 0 Ω do 100 Ω CMC 20 mΩ OST od 100 Ω do 400 Ω CMC 0,01 % + 10 mΩ OST od 400 Ω do 4000 Ω CMC 0,015 % + 20 mΩ Mereni a simulace signalu snimacu teploty / meridla teploty Kalibrace – elektricke veliciny Prime generovani odporu kalibratorem / odporovou dekadou OST 0 Ω az 100 Ω CMC 20 mΩ OST 100 Ω az 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω az 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07","search_en":"Measurement and simulation of temperature sensors / temperature gauges Calibration – electrical quantities Direct resistance generation by a calibrator / resistance box OST 0 Ω to 100 Ω CMC 20 mΩ OST 100 Ω to 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω to 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07","search_zh":"温度传感器信号的测量和模拟 / 温度测量仪器 校准 – 电学量 用校准器 / 电阻箱直接产生电阻 OST 0 Ω 至 100 Ω CMC 20 mΩ OST 100 Ω 至 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω 至 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"905d68e6bec25fd7301de0d2","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"9","test_object":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury","test_object_en":"Measurement and simulation of temperature sensors / temperature gauges","test_object_zh":"温度传感器信号的测量和模拟 / 温度测量仪器","test_object_cs":"Měření a simulace signálů snímačů teploty / měřidla teploty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"OST","range":"od 0 Ω do 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"od 100 Ω do 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"od 400 Ω do 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"parameters_en":[{"name":"OST","range":"0 Ω to 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"100 Ω to 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"400 Ω to 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"parameters_zh":[{"name":"OST","range":"0 Ω 至 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"100 Ω 至 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"400 Ω 至 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"parameters_cs":[{"name":"OST","range":"0 Ω až 100 Ω","cmc":"20 mΩ"},{"name":"OST","range":"100 Ω až 400 Ω","cmc":"0,01 % + 10 mΩ"},{"name":"OST","range":"400 Ω až 4000 Ω","cmc":"0,015 % + 20 mΩ"}],"technique":"Bezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną","technique_en":"Direct resistance generation by a calibrator / resistance box","technique_zh":"用校准器 / 电阻箱直接产生电阻","technique_cs":"Přímé generování odporu kalibrátorem / odporovou dekádou","techniques":["Bezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną"],"techniques_en":["Direct resistance generation by a calibrator / resistance box"],"techniques_zh":["用校准器 / 电阻箱直接产生电阻"],"techniques_cs":["Přímé generování odporu kalibrátorem / odporovou dekádou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nOST od 0 Ω do 100 Ω CMC 20 mΩ\nOST od 100 Ω do 400 Ω CMC 0,01 % + 10 mΩ\nOST od 400 Ω do 4000 Ω CMC 0,015 % + 20 mΩ\nBezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną","reference":"J 62.03.T07","norm_bases":["J 62.03.T07"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie rezystancji kalibratorem / dekadą rezystancyjną OST od 0 Ω do 100 Ω CMC 20 mΩ OST od 100 Ω do 400 Ω CMC 0,01 % + 10 mΩ OST od 400 Ω do 4000 Ω CMC 0,015 % + 20 mΩ Měření a simulace signálů snímačů teploty / měřidla teploty Kalibrace – elektrické veličiny Přímé generování odporu kalibrátorem / odporovou dekádou OST 0 Ω až 100 Ω CMC 20 mΩ OST 100 Ω až 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω až 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07 Pomiar i symulacja sygnalow czujnikow temperatury / przyrzady do pomiaru temperatury Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie rezystancji kalibratorem / dekada rezystancyjna OST od 0 Ω do 100 Ω CMC 20 mΩ OST od 100 Ω do 400 Ω CMC 0,01 % + 10 mΩ OST od 400 Ω do 4000 Ω CMC 0,015 % + 20 mΩ Mereni a simulace signalu snimacu teploty / meridla teploty Kalibrace – elektricke veliciny Prime generovani odporu kalibratorem / odporovou dekadou OST 0 Ω az 100 Ω CMC 20 mΩ OST 100 Ω az 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω az 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07","search_en":"Measurement and simulation of temperature sensors / temperature gauges Calibration – electrical quantities Direct resistance generation by a calibrator / resistance box OST 0 Ω to 100 Ω CMC 20 mΩ OST 100 Ω to 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω to 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07","search_zh":"温度传感器信号的测量和模拟 / 温度测量仪器 校准 – 电学量 用校准器 / 电阻箱直接产生电阻 OST 0 Ω 至 100 Ω CMC 20 mΩ OST 100 Ω 至 400 Ω CMC 0,01 % + 10 mΩ OST 400 Ω 至 4000 Ω CMC 0,015 % + 20 mΩ J 62.03.T07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0575c6b32c0cf414b63d9954","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"9","test_object":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury","test_object_en":"Measurement and simulation of temperature sensors / temperature gauges","test_object_zh":"温度传感器信号的测量和模拟 / 温度测量仪器","test_object_cs":"Měření a simulace signálů snímačů teploty / měřidla teploty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"TC","range":"od −10 mV do 60 mV","cmc":"0,007 % + 4 µV"}],"parameters_en":[{"name":"TC","range":"−10 mV to 60 mV","cmc":"0,007 % + 4 µV"}],"parameters_zh":[{"name":"TC","range":"−10 mV 至 60 mV","cmc":"0,007 % + 4 µV"}],"parameters_cs":[{"name":"TC","range":"−10 mV až 60 mV","cmc":"0,007 % + 4 µV"}],"technique":"Bezpośrednie generowanie napięcia kalibratorem","technique_en":"Direct voltage generation by a calibrator","technique_zh":"用校准器直接产生电压","technique_cs":"Přímé generování napětí kalibrátorem","techniques":["Bezpośrednie generowanie napięcia kalibratorem"],"techniques_en":["Direct voltage generation by a calibrator"],"techniques_zh":["用校准器直接产生电压"],"techniques_cs":["Přímé generování napětí kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nTC od −10 mV do 60 mV CMC 0,007 % + 4 µV\nBezpośrednie generowanie napięcia kalibratorem","reference":"J 62.03.T07","norm_bases":["J 62.03.T07"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie napięcia kalibratorem TC od −10 mV do 60 mV CMC 0,007 % + 4 µV Měření a simulace signálů snímačů teploty / měřidla teploty Kalibrace – elektrické veličiny Přímé generování napětí kalibrátorem TC −10 mV až 60 mV CMC 0,007 % + 4 µV J 62.03.T07 Pomiar i symulacja sygnalow czujnikow temperatury / przyrzady do pomiaru temperatury Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie napiecia kalibratorem TC od −10 mV do 60 mV CMC 0,007 % + 4 µV Mereni a simulace signalu snimacu teploty / meridla teploty Kalibrace – elektricke veliciny Prime generovani napeti kalibratorem TC −10 mV az 60 mV CMC 0,007 % + 4 µV J 62.03.T07","search_en":"Measurement and simulation of temperature sensors / temperature gauges Calibration – electrical quantities Direct voltage generation by a calibrator TC −10 mV to 60 mV CMC 0,007 % + 4 µV J 62.03.T07","search_zh":"温度传感器信号的测量和模拟 / 温度测量仪器 校准 – 电学量 用校准器直接产生电压 TC −10 mV 至 60 mV CMC 0,007 % + 4 µV J 62.03.T07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":84,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"828574668182478b7536d5a6","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"9","test_object":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury","test_object_en":"Measurement and simulation of temperature sensors / temperature gauges","test_object_zh":"温度传感器信号的测量和模拟 / 温度测量仪器","test_object_cs":"Měření a simulace signálů snímačů teploty / měřidla teploty","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"TC","range":"od −10 mV do 60 mV","cmc":"0,007 % + 4 µV"}],"parameters_en":[{"name":"TC","range":"−10 mV to 60 mV","cmc":"0,007 % + 4 µV"}],"parameters_zh":[{"name":"TC","range":"−10 mV 至 60 mV","cmc":"0,007 % + 4 µV"}],"parameters_cs":[{"name":"TC","range":"−10 mV až 60 mV","cmc":"0,007 % + 4 µV"}],"technique":"Bezpośrednie generowanie napięcia kalibratorem","technique_en":"Direct voltage generation by a calibrator","technique_zh":"用校准器直接产生电压","technique_cs":"Přímé generování napětí kalibrátorem","techniques":["Bezpośrednie generowanie napięcia kalibratorem"],"techniques_en":["Direct voltage generation by a calibrator"],"techniques_zh":["用校准器直接产生电压"],"techniques_cs":["Přímé generování napětí kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nTC od −10 mV do 60 mV CMC 0,007 % + 4 µV\nBezpośrednie generowanie napięcia kalibratorem","reference":"J 62.03.T07","norm_bases":["J 62.03.T07"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomiar i symulacja sygnałów czujników temperatury / przyrządy do pomiaru temperatury Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie napięcia kalibratorem TC od −10 mV do 60 mV CMC 0,007 % + 4 µV Měření a simulace signálů snímačů teploty / měřidla teploty Kalibrace – elektrické veličiny Přímé generování napětí kalibrátorem TC −10 mV až 60 mV CMC 0,007 % + 4 µV J 62.03.T07 Pomiar i symulacja sygnalow czujnikow temperatury / przyrzady do pomiaru temperatury Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie napiecia kalibratorem TC od −10 mV do 60 mV CMC 0,007 % + 4 µV Mereni a simulace signalu snimacu teploty / meridla teploty Kalibrace – elektricke veliciny Prime generovani napeti kalibratorem TC −10 mV az 60 mV CMC 0,007 % + 4 µV J 62.03.T07","search_en":"Measurement and simulation of temperature sensors / temperature gauges Calibration – electrical quantities Direct voltage generation by a calibrator TC −10 mV to 60 mV CMC 0,007 % + 4 µV J 62.03.T07","search_zh":"温度传感器信号的测量和模拟 / 温度测量仪器 校准 – 电学量 用校准器直接产生电压 TC −10 mV 至 60 mV CMC 0,007 % + 4 µV J 62.03.T07","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":85,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ae258aaa7dd0b394c46e40cf","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"10","test_object":"Impedancja sieci / mierniki do badań instalacji elektrycznych","test_object_en":"Mains impedance / Inspection instruments","test_object_zh":"电网阻抗 / 电气安装检测仪","test_object_cs":"Impedance sítě / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"parameters_en":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"parameters_zh":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"parameters_cs":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n25 mΩ CMC 5 mΩ\n50 mΩ CMC 5 mΩ\n100 mΩ CMC 5 mΩ\n330 mΩ CMC 7 mΩ\n500 mΩ CMC 8 mΩ\n1 Ω CMC 10 mΩ\n1,8 Ω CMC 18 mΩ\n5 Ω CMC 30 mΩ\n10 Ω CMC 60 mΩ\n18 Ω CMC 100 mΩ\n50 Ω CMC 300 mΩ\n100 Ω CMC 500 mΩ\n180 Ω CMC 1 Ω\n500 Ω CMC 2.5 Ω\n1 kΩ CMC 5 Ω\n1,8 kΩ CMC 10 Ω\nBezpośrednie generowanie kalibratorem","reference":"62.03.E15.0 kap. 7.3.6","norm_bases":["62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja sieci / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω Impedance sítě / Revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6 Impedancja sieci / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω Impedance site / Revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6","search_en":"Mains impedance / Inspection instruments Calibration – electrical quantities Direct generation with a calibrator 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6","search_zh":"电网阻抗 / 电气安装检测仪 校准 – 电学量 用校准器直接产生 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":86,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd2ccfb449ea2958833a5d15","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"10","test_object":"Impedancja sieci / mierniki do badań instalacji elektrycznych","test_object_en":"Mains impedance / Inspection instruments","test_object_zh":"电网阻抗 / 电气安装检测仪","test_object_cs":"Impedance sítě / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"parameters_en":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"parameters_zh":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"parameters_cs":[{"name":"","range":"25 mΩ","cmc":"5 mΩ"},{"name":"","range":"50 mΩ","cmc":"5 mΩ"},{"name":"","range":"100 mΩ","cmc":"5 mΩ"},{"name":"","range":"330 mΩ","cmc":"7 mΩ"},{"name":"","range":"500 mΩ","cmc":"8 mΩ"},{"name":"","range":"1 Ω","cmc":"10 mΩ"},{"name":"","range":"1,8 Ω","cmc":"18 mΩ"},{"name":"","range":"5 Ω","cmc":"30 mΩ"},{"name":"","range":"10 Ω","cmc":"60 mΩ"},{"name":"","range":"18 Ω","cmc":"100 mΩ"},{"name":"","range":"50 Ω","cmc":"300 mΩ"},{"name":"","range":"100 Ω","cmc":"500 mΩ"},{"name":"","range":"180 Ω","cmc":"1 Ω"},{"name":"","range":"500 Ω","cmc":"2.5 Ω"},{"name":"","range":"1 kΩ","cmc":"5 Ω"},{"name":"","range":"1,8 kΩ","cmc":"10 Ω"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n25 mΩ CMC 5 mΩ\n50 mΩ CMC 5 mΩ\n100 mΩ CMC 5 mΩ\n330 mΩ CMC 7 mΩ\n500 mΩ CMC 8 mΩ\n1 Ω CMC 10 mΩ\n1,8 Ω CMC 18 mΩ\n5 Ω CMC 30 mΩ\n10 Ω CMC 60 mΩ\n18 Ω CMC 100 mΩ\n50 Ω CMC 300 mΩ\n100 Ω CMC 500 mΩ\n180 Ω CMC 1 Ω\n500 Ω CMC 2.5 Ω\n1 kΩ CMC 5 Ω\n1,8 kΩ CMC 10 Ω\nBezpośrednie generowanie kalibratorem","reference":"62.03.E15.0 kap. 7.3.6","norm_bases":["62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Impedancja sieci / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω Impedance sítě / Revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6 Impedancja sieci / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω Impedance site / Revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6","search_en":"Mains impedance / Inspection instruments Calibration – electrical quantities Direct generation with a calibrator 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6","search_zh":"电网阻抗 / 电气安装检测仪 校准 – 电学量 用校准器直接产生 25 mΩ CMC 5 mΩ 50 mΩ CMC 5 mΩ 100 mΩ CMC 5 mΩ 330 mΩ CMC 7 mΩ 500 mΩ CMC 8 mΩ 1 Ω CMC 10 mΩ 1,8 Ω CMC 18 mΩ 5 Ω CMC 30 mΩ 10 Ω CMC 60 mΩ 18 Ω CMC 100 mΩ 50 Ω CMC 300 mΩ 100 Ω CMC 500 mΩ 180 Ω CMC 1 Ω 500 Ω CMC 2.5 Ω 1 kΩ CMC 5 Ω 1,8 kΩ CMC 10 Ω 62.03.E15.0 kap. 7.3.6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":87,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"efe56dab3c15cdcc784ef0c0","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"11","test_object":"Prąd upływu / mierniki do badań instalacji elektrycznych","test_object_en":"Leakage current / Inspection instruments","test_object_zh":"泄漏电流 / 电气安装检测仪","test_object_cs":"Unikající proud / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 mA do 1 mA","cmc":"0,5 %"},{"name":"","range":"od 1 mA do 30 mA","cmc":"0,32 %"}],"parameters_en":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,5 %"},{"name":"","range":"1 mA to 30 mA","cmc":"0,32 %"}],"parameters_zh":[{"name":"","range":"0,1 mA 至 1 mA","cmc":"0,5 %"},{"name":"","range":"1 mA 至 30 mA","cmc":"0,32 %"}],"parameters_cs":[{"name":"","range":"0,1 mA až 1 mA","cmc":"0,5 %"},{"name":"","range":"1 mA až 30 mA","cmc":"0,32 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,1 mA do 1 mA CMC 0,5 %\nod 1 mA do 30 mA CMC 0,32 %\nBezpośrednie generowanie kalibratorem","reference":"62.03.E15.0 kap. 7.3.7","norm_bases":["62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd upływu / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0,1 mA do 1 mA CMC 0,5 % od 1 mA do 30 mA CMC 0,32 % Unikající proud / Revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0,1 mA až 1 mA CMC 0,5 % 1 mA až 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7 Prad uplywu / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0,1 mA do 1 mA CMC 0,5 % od 1 mA do 30 mA CMC 0,32 % Unikajici proud / Revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 0,1 mA az 1 mA CMC 0,5 % 1 mA az 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7","search_en":"Leakage current / Inspection instruments Calibration – electrical quantities Direct generation with a calibrator 0,1 mA to 1 mA CMC 0,5 % 1 mA to 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7","search_zh":"泄漏电流 / 电气安装检测仪 校准 – 电学量 用校准器直接产生 0,1 mA 至 1 mA CMC 0,5 % 1 mA 至 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":88,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a266888e6319d13622bf3f9b","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"11","test_object":"Prąd upływu / mierniki do badań instalacji elektrycznych","test_object_en":"Leakage current / Inspection instruments","test_object_zh":"泄漏电流 / 电气安装检测仪","test_object_cs":"Unikající proud / Revizní přístroje","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,1 mA do 1 mA","cmc":"0,5 %"},{"name":"","range":"od 1 mA do 30 mA","cmc":"0,32 %"}],"parameters_en":[{"name":"","range":"0,1 mA to 1 mA","cmc":"0,5 %"},{"name":"","range":"1 mA to 30 mA","cmc":"0,32 %"}],"parameters_zh":[{"name":"","range":"0,1 mA 至 1 mA","cmc":"0,5 %"},{"name":"","range":"1 mA 至 30 mA","cmc":"0,32 %"}],"parameters_cs":[{"name":"","range":"0,1 mA až 1 mA","cmc":"0,5 %"},{"name":"","range":"1 mA až 30 mA","cmc":"0,32 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,1 mA do 1 mA CMC 0,5 %\nod 1 mA do 30 mA CMC 0,32 %\nBezpośrednie generowanie kalibratorem","reference":"62.03.E15.0 kap. 7.3.7","norm_bases":["62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd upływu / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości elektryczne Bezpośrednie generowanie kalibratorem od 0,1 mA do 1 mA CMC 0,5 % od 1 mA do 30 mA CMC 0,32 % Unikající proud / Revizní přístroje Kalibrace – elektrické veličiny Přímé generování kalibrátorem 0,1 mA až 1 mA CMC 0,5 % 1 mA až 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7 Prad uplywu / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci elektryczne Bezposrednie generowanie kalibratorem od 0,1 mA do 1 mA CMC 0,5 % od 1 mA do 30 mA CMC 0,32 % Unikajici proud / Revizni pristroje Kalibrace – elektricke veliciny Prime generovani kalibratorem 0,1 mA az 1 mA CMC 0,5 % 1 mA az 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7","search_en":"Leakage current / Inspection instruments Calibration – electrical quantities Direct generation with a calibrator 0,1 mA to 1 mA CMC 0,5 % 1 mA to 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7","search_zh":"泄漏电流 / 电气安装检测仪 校准 – 电学量 用校准器直接产生 0,1 mA 至 1 mA CMC 0,5 % 1 mA 至 30 mA CMC 0,32 % 62.03.E15.0 kap. 7.3.7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":89,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d39f3a18f30e92932a3a3370","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"1","test_object":"Częstotliwość / elektroniczne liczniki i generatory","test_object_en":"Frequency / Electronic counters and generators","test_object_zh":"频率 / 电子计数器和发生器","test_object_cs":"Frekvence / Elektronické čítače a generátory","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 1 Hz do 100 Hz","cmc":"2,5·10⁻⁶ Hz"},{"name":"","range":"od 100 Hz do 1 kHz","cmc":"1,2·10⁻⁶ Hz"},{"name":"","range":"od 1 kHz do 10 kHz","cmc":"1,5·10⁻⁶ Hz"},{"name":"","range":"od 10 kHz do 100 kHz","cmc":"1,6·10⁻⁶ Hz"},{"name":"","range":"od 100 kHz do 1 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"od 1 MHz do 10 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"od 10 MHz do 100 MHz","cmc":"1,5·10⁻⁴ Hz"},{"name":"","range":"od 100 MHz do 1 GHz","cmc":"3,5·10⁻² Hz"}],"parameters_en":[{"name":"","range":"1 Hz to 100 Hz","cmc":"2,5·10⁻⁶ Hz"},{"name":"","range":"100 Hz to 1 kHz","cmc":"1,2·10⁻⁶ Hz"},{"name":"","range":"1 kHz to 10 kHz","cmc":"1,5·10⁻⁶ Hz"},{"name":"","range":"10 kHz to 100 kHz","cmc":"1,6·10⁻⁶ Hz"},{"name":"","range":"100 kHz to 1 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"1 MHz to 10 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"10 MHz to 100 MHz","cmc":"1,5·10⁻⁴ Hz"},{"name":"","range":"100 MHz to 1 GHz","cmc":"3,5·10⁻² Hz"}],"parameters_zh":[{"name":"","range":"1 Hz 至 100 Hz","cmc":"2,5·10⁻⁶ Hz"},{"name":"","range":"100 Hz 至 1 kHz","cmc":"1,2·10⁻⁶ Hz"},{"name":"","range":"1 kHz 至 10 kHz","cmc":"1,5·10⁻⁶ Hz"},{"name":"","range":"10 kHz 至 100 kHz","cmc":"1,6·10⁻⁶ Hz"},{"name":"","range":"100 kHz 至 1 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"1 MHz 至 10 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"10 MHz 至 100 MHz","cmc":"1,5·10⁻⁴ Hz"},{"name":"","range":"100 MHz 至 1 GHz","cmc":"3,5·10⁻² Hz"}],"parameters_cs":[{"name":"","range":"1 Hz až 100 Hz","cmc":"2,5·10⁻⁶ Hz"},{"name":"","range":"100 Hz až 1 kHz","cmc":"1,2·10⁻⁶ Hz"},{"name":"","range":"1 kHz až 10 kHz","cmc":"1,5·10⁻⁶ Hz"},{"name":"","range":"10 kHz až 100 kHz","cmc":"1,6·10⁻⁶ Hz"},{"name":"","range":"100 kHz až 1 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"1 MHz až 10 MHz","cmc":"3,6·10⁻⁵ Hz"},{"name":"","range":"10 MHz až 100 MHz","cmc":"1,5·10⁻⁴ Hz"},{"name":"","range":"100 MHz až 1 GHz","cmc":"3,5·10⁻² Hz"}],"technique":"Bezpośrednie generowanie (pomiar) generatorem (licznikiem) sterowanym z odbiornika GPS","technique_en":"Direct generation (measurement) by a generator (counter) controlled from a GPS receiver","technique_zh":"用由 GPS 接收机控制的发生器（计数器）直接产生（测量）","technique_cs":"Přímé generování (měření) generátorem (čítačem) řízených z GPS přijímače","techniques":["Bezpośrednie generowanie (pomiar) generatorem (licznikiem) sterowanym z odbiornika GPS"],"techniques_en":["Direct generation (measurement) by a generator (counter) controlled from a GPS receiver"],"techniques_zh":["用由 GPS 接收机控制的发生器（计数器）直接产生（测量）"],"techniques_cs":["Přímé generování (měření) generátorem (čítačem) řízených z GPS přijímače"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 1 Hz do 100 Hz CMC 2,5·10⁻⁶ Hz\nod 100 Hz do 1 kHz CMC 1,2·10⁻⁶ Hz\nod 1 kHz do 10 kHz CMC 1,5·10⁻⁶ Hz\nod 10 kHz do 100 kHz CMC 1,6·10⁻⁶ Hz\nod 100 kHz do 1 MHz CMC 3,6·10⁻⁵ Hz\nod 1 MHz do 10 MHz CMC 3,6·10⁻⁵ Hz\nod 10 MHz do 100 MHz CMC 1,5·10⁻⁴ Hz\nod 100 MHz do 1 GHz CMC 3,5·10⁻² Hz\nBezpośrednie generowanie (pomiar) generatorem (licznikiem) sterowanym z odbiornika GPS","reference":"J 62.03.E06.0, J 62.03.E07.0","norm_bases":["J 62.03.E06.0","J 62.03.E07.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Częstotliwość / elektroniczne liczniki i generatory Wzorcowanie – wielkości czasu i częstotliwości Bezpośrednie generowanie (pomiar) generatorem (licznikiem) sterowanym z odbiornika GPS od 1 Hz do 100 Hz CMC 2,5·10⁻⁶ Hz od 100 Hz do 1 kHz CMC 1,2·10⁻⁶ Hz od 1 kHz do 10 kHz CMC 1,5·10⁻⁶ Hz od 10 kHz do 100 kHz CMC 1,6·10⁻⁶ Hz od 100 kHz do 1 MHz CMC 3,6·10⁻⁵ Hz od 1 MHz do 10 MHz CMC 3,6·10⁻⁵ Hz od 10 MHz do 100 MHz CMC 1,5·10⁻⁴ Hz od 100 MHz do 1 GHz CMC 3,5·10⁻² Hz Frekvence / Elektronické čítače a generátory Kalibrace – veličiny času a frekvence Přímé generování (měření) generátorem (čítačem) řízených z GPS přijímače 1 Hz až 100 Hz CMC 2,5·10⁻⁶ Hz 100 Hz až 1 kHz CMC 1,2·10⁻⁶ Hz 1 kHz až 10 kHz CMC 1,5·10⁻⁶ Hz 10 kHz až 100 kHz CMC 1,6·10⁻⁶ Hz 100 kHz až 1 MHz CMC 3,6·10⁻⁵ Hz 1 MHz až 10 MHz CMC 3,6·10⁻⁵ Hz 10 MHz až 100 MHz CMC 1,5·10⁻⁴ Hz 100 MHz až 1 GHz CMC 3,5·10⁻² Hz J 62.03.E06.0, J 62.03.E07.0 Czestotliwosc / elektroniczne liczniki i generatory Wzorcowanie – wielkosci czasu i czestotliwosci Bezposrednie generowanie (pomiar) generatorem (licznikiem) sterowanym z odbiornika GPS od 1 Hz do 100 Hz CMC 2,5·10⁻⁶ Hz od 100 Hz do 1 kHz CMC 1,2·10⁻⁶ Hz od 1 kHz do 10 kHz CMC 1,5·10⁻⁶ Hz od 10 kHz do 100 kHz CMC 1,6·10⁻⁶ Hz od 100 kHz do 1 MHz CMC 3,6·10⁻⁵ Hz od 1 MHz do 10 MHz CMC 3,6·10⁻⁵ Hz od 10 MHz do 100 MHz CMC 1,5·10⁻⁴ Hz od 100 MHz do 1 GHz CMC 3,5·10⁻² Hz Frekvence / Elektronicke citace a generatory Kalibrace – veliciny casu a frekvence Prime generovani (mereni) generatorem (citacem) rizenych z GPS prijimace 1 Hz az 100 Hz CMC 2,5·10⁻⁶ Hz 100 Hz az 1 kHz CMC 1,2·10⁻⁶ Hz 1 kHz az 10 kHz CMC 1,5·10⁻⁶ Hz 10 kHz az 100 kHz CMC 1,6·10⁻⁶ Hz 100 kHz az 1 MHz CMC 3,6·10⁻⁵ Hz 1 MHz az 10 MHz CMC 3,6·10⁻⁵ Hz 10 MHz az 100 MHz CMC 1,5·10⁻⁴ Hz 100 MHz az 1 GHz CMC 3,5·10⁻² Hz J 62.03.E06.0, J 62.03.E07.0","search_en":"Frequency / Electronic counters and generators Calibration – time and frequency quantities Direct generation (measurement) by a generator (counter) controlled from a GPS receiver 1 Hz to 100 Hz CMC 2,5·10⁻⁶ Hz 100 Hz to 1 kHz CMC 1,2·10⁻⁶ Hz 1 kHz to 10 kHz CMC 1,5·10⁻⁶ Hz 10 kHz to 100 kHz CMC 1,6·10⁻⁶ Hz 100 kHz to 1 MHz CMC 3,6·10⁻⁵ Hz 1 MHz to 10 MHz CMC 3,6·10⁻⁵ Hz 10 MHz to 100 MHz CMC 1,5·10⁻⁴ Hz 100 MHz to 1 GHz CMC 3,5·10⁻² Hz J 62.03.E06.0, J 62.03.E07.0","search_zh":"频率 / 电子计数器和发生器 校准 – 时间和频率量 用由 GPS 接收机控制的发生器（计数器）直接产生（测量） 1 Hz 至 100 Hz CMC 2,5·10⁻⁶ Hz 100 Hz 至 1 kHz CMC 1,2·10⁻⁶ Hz 1 kHz 至 10 kHz CMC 1,5·10⁻⁶ Hz 10 kHz 至 100 kHz CMC 1,6·10⁻⁶ Hz 100 kHz 至 1 MHz CMC 3,6·10⁻⁵ Hz 1 MHz 至 10 MHz CMC 3,6·10⁻⁵ Hz 10 MHz 至 100 MHz CMC 1,5·10⁻⁴ Hz 100 MHz 至 1 GHz CMC 3,5·10⁻² Hz J 62.03.E06.0, J 62.03.E07.0","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":90,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9e1d001dc9cc2a7add903560","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Czas / mierniki do badań instalacji elektrycznych","test_object_en":"Time / Inspection equipment","test_object_zh":"时间 / 电气安装检测仪","test_object_cs":"Čas / Revizní přístroje","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 10 ms do 50 ms","cmc":"0,52 %"},{"name":"","range":"od 50 ms do 100 ms","cmc":"0,27 %"},{"name":"","range":"od 100 ms do 500 ms","cmc":"0,07 %"},{"name":"","range":"od 500 ms do 1 s","cmc":"0,045 %"},{"name":"","range":"od 1 s do 5 s","cmc":"0,025 %"}],"parameters_en":[{"name":"","range":"10 ms to 50 ms","cmc":"0,52 %"},{"name":"","range":"50 ms to 100 ms","cmc":"0,27 %"},{"name":"","range":"100 ms to 500 ms","cmc":"0,07 %"},{"name":"","range":"500 ms to 1 s","cmc":"0,045 %"},{"name":"","range":"1 s to 5 s","cmc":"0,025 %"}],"parameters_zh":[{"name":"","range":"10 ms 至 50 ms","cmc":"0,52 %"},{"name":"","range":"50 ms 至 100 ms","cmc":"0,27 %"},{"name":"","range":"100 ms 至 500 ms","cmc":"0,07 %"},{"name":"","range":"500 ms 至 1 s","cmc":"0,045 %"},{"name":"","range":"1 s 至 5 s","cmc":"0,025 %"}],"parameters_cs":[{"name":"","range":"10 ms až 50 ms","cmc":"0,52 %"},{"name":"","range":"50 ms až 100 ms","cmc":"0,27 %"},{"name":"","range":"100 ms až 500 ms","cmc":"0,07 %"},{"name":"","range":"500 ms až 1 s","cmc":"0,045 %"},{"name":"","range":"1 s až 5 s","cmc":"0,025 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 10 ms do 50 ms CMC 0,52 %\nod 50 ms do 100 ms CMC 0,27 %\nod 100 ms do 500 ms CMC 0,07 %\nod 500 ms do 1 s CMC 0,045 %\nod 1 s do 5 s CMC 0,025 %\nBezpośrednie generowanie kalibratorem","reference":"62.03.E15.0 kap. 7.3.9","norm_bases":["62.03.E15.0"],"lab_section":"Elektrownia jądrowa Dukovany","lab_section_en":"Nuclear Power Plant Dukovany","lab_section_zh":"杜科瓦尼核电站","lab_section_cs":"Jaderná elektrárna Dukovany","lab_address":"Modřínová 1094, 674 01 Třebíč","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czas / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości czasu i częstotliwości Bezpośrednie generowanie kalibratorem od 10 ms do 50 ms CMC 0,52 % od 50 ms do 100 ms CMC 0,27 % od 100 ms do 500 ms CMC 0,07 % od 500 ms do 1 s CMC 0,045 % od 1 s do 5 s CMC 0,025 % Čas / Revizní přístroje Kalibrace – veličiny času a frekvence Přímé generování kalibrátorem 10 ms až 50 ms CMC 0,52 % 50 ms až 100 ms CMC 0,27 % 100 ms až 500 ms CMC 0,07 % 500 ms až 1 s CMC 0,045 % 1 s až 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9 Czas / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu i czestotliwosci Bezposrednie generowanie kalibratorem od 10 ms do 50 ms CMC 0,52 % od 50 ms do 100 ms CMC 0,27 % od 100 ms do 500 ms CMC 0,07 % od 500 ms do 1 s CMC 0,045 % od 1 s do 5 s CMC 0,025 % Cas / Revizni pristroje Kalibrace – veliciny casu a frekvence Prime generovani kalibratorem 10 ms az 50 ms CMC 0,52 % 50 ms az 100 ms CMC 0,27 % 100 ms az 500 ms CMC 0,07 % 500 ms az 1 s CMC 0,045 % 1 s az 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9","search_en":"Time / Inspection equipment Calibration – time and frequency quantities Direct generation with a calibrator 10 ms to 50 ms CMC 0,52 % 50 ms to 100 ms CMC 0,27 % 100 ms to 500 ms CMC 0,07 % 500 ms to 1 s CMC 0,045 % 1 s to 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9","search_zh":"时间 / 电气安装检测仪 校准 – 时间和频率量 用校准器直接产生 10 ms 至 50 ms CMC 0,52 % 50 ms 至 100 ms CMC 0,27 % 100 ms 至 500 ms CMC 0,07 % 500 ms 至 1 s CMC 0,045 % 1 s 至 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":91,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7a14fa49e150087afe1b7876","lab_id":"6ade8b29ff068247617080fc","country":"CZ","accr_number":"2245","accr_body":"ČIA","row_label":"2","test_object":"Czas / mierniki do badań instalacji elektrycznych","test_object_en":"Time / Inspection equipment","test_object_zh":"时间 / 电气安装检测仪","test_object_cs":"Čas / Revizní přístroje","methodology":"Wzorcowanie – wielkości czasu i częstotliwości","methodology_en":"Calibration – time and frequency quantities","methodology_zh":"校准 – 时间和频率量","methodology_cs":"Kalibrace – veličiny času a frekvence","parameters":[{"name":"","range":"od 10 ms do 50 ms","cmc":"0,52 %"},{"name":"","range":"od 50 ms do 100 ms","cmc":"0,27 %"},{"name":"","range":"od 100 ms do 500 ms","cmc":"0,07 %"},{"name":"","range":"od 500 ms do 1 s","cmc":"0,045 %"},{"name":"","range":"od 1 s do 5 s","cmc":"0,025 %"}],"parameters_en":[{"name":"","range":"10 ms to 50 ms","cmc":"0,52 %"},{"name":"","range":"50 ms to 100 ms","cmc":"0,27 %"},{"name":"","range":"100 ms to 500 ms","cmc":"0,07 %"},{"name":"","range":"500 ms to 1 s","cmc":"0,045 %"},{"name":"","range":"1 s to 5 s","cmc":"0,025 %"}],"parameters_zh":[{"name":"","range":"10 ms 至 50 ms","cmc":"0,52 %"},{"name":"","range":"50 ms 至 100 ms","cmc":"0,27 %"},{"name":"","range":"100 ms 至 500 ms","cmc":"0,07 %"},{"name":"","range":"500 ms 至 1 s","cmc":"0,045 %"},{"name":"","range":"1 s 至 5 s","cmc":"0,025 %"}],"parameters_cs":[{"name":"","range":"10 ms až 50 ms","cmc":"0,52 %"},{"name":"","range":"50 ms až 100 ms","cmc":"0,27 %"},{"name":"","range":"100 ms až 500 ms","cmc":"0,07 %"},{"name":"","range":"500 ms až 1 s","cmc":"0,045 %"},{"name":"","range":"1 s až 5 s","cmc":"0,025 %"}],"technique":"Bezpośrednie generowanie kalibratorem","technique_en":"Direct generation with a calibrator","technique_zh":"用校准器直接产生","technique_cs":"Přímé generování kalibrátorem","techniques":["Bezpośrednie generowanie kalibratorem"],"techniques_en":["Direct generation with a calibrator"],"techniques_zh":["用校准器直接产生"],"techniques_cs":["Přímé generování kalibrátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości czasu i częstotliwości\nZakres:\nod 10 ms do 50 ms CMC 0,52 %\nod 50 ms do 100 ms CMC 0,27 %\nod 100 ms do 500 ms CMC 0,07 %\nod 500 ms do 1 s CMC 0,045 %\nod 1 s do 5 s CMC 0,025 %\nBezpośrednie generowanie kalibratorem","reference":"62.03.E15.0 kap. 7.3.9","norm_bases":["62.03.E15.0"],"lab_section":"Elektrownia jądrowa Temelín","lab_section_en":"Nuclear Power Plant Temelín","lab_section_zh":"泰梅林核电站","lab_section_cs":"Jaderná elektrárna Temelín","lab_address":"373 05 Temelín","regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości czasu i częstotliwości","regulatory_area_en":"CMC for the field of measured quantity: Time and frequency quantities","regulatory_area_zh":"被测量领域的CMC：时间和频率量","regulatory_area_cs":"CMC pro obor měřené veličiny: Veličiny času a frekvence","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Czas / mierniki do badań instalacji elektrycznych Wzorcowanie – wielkości czasu i częstotliwości Bezpośrednie generowanie kalibratorem od 10 ms do 50 ms CMC 0,52 % od 50 ms do 100 ms CMC 0,27 % od 100 ms do 500 ms CMC 0,07 % od 500 ms do 1 s CMC 0,045 % od 1 s do 5 s CMC 0,025 % Čas / Revizní přístroje Kalibrace – veličiny času a frekvence Přímé generování kalibrátorem 10 ms až 50 ms CMC 0,52 % 50 ms až 100 ms CMC 0,27 % 100 ms až 500 ms CMC 0,07 % 500 ms až 1 s CMC 0,045 % 1 s až 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9 Czas / mierniki do badan instalacji elektrycznych Wzorcowanie – wielkosci czasu i czestotliwosci Bezposrednie generowanie kalibratorem od 10 ms do 50 ms CMC 0,52 % od 50 ms do 100 ms CMC 0,27 % od 100 ms do 500 ms CMC 0,07 % od 500 ms do 1 s CMC 0,045 % od 1 s do 5 s CMC 0,025 % Cas / Revizni pristroje Kalibrace – veliciny casu a frekvence Prime generovani kalibratorem 10 ms az 50 ms CMC 0,52 % 50 ms az 100 ms CMC 0,27 % 100 ms az 500 ms CMC 0,07 % 500 ms az 1 s CMC 0,045 % 1 s az 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9","search_en":"Time / Inspection equipment Calibration – time and frequency quantities Direct generation with a calibrator 10 ms to 50 ms CMC 0,52 % 50 ms to 100 ms CMC 0,27 % 100 ms to 500 ms CMC 0,07 % 500 ms to 1 s CMC 0,045 % 1 s to 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9","search_zh":"时间 / 电气安装检测仪 校准 – 时间和频率量 用校准器直接产生 10 ms 至 50 ms CMC 0,52 % 50 ms 至 100 ms CMC 0,27 % 100 ms 至 500 ms CMC 0,07 % 500 ms 至 1 s CMC 0,045 % 1 s 至 5 s CMC 0,025 % 62.03.E15.0 kap. 7.3.9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":92,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}