Strojírny a stavby Třinec, a.s. is a calibration laboratory accredited by ČIA under number 2241 (Třinec, Czech Republic). Its accreditation scope covers 15 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC current / AC current meters (digital and analogue multimeters, a…, AC current / current sources, DC current / DC current meters (digital and analogue multimeters, a…, DC resistance / ohmmeters. Most frequently used calibration principles: Direct measurement with a standard multimeter, Direct measurement on a standard calibrator or by comparison with a…, Indirect measurement – measurement of simulated current (standard c….

At a glance

  • Accreditation number: ČIA 2241
  • Calibration items in scope: 15
  • Types of calibrated items: 11
  • Calibration principles used: 7
  • City: Třinec, Czech Republic
  • Valid until: 20-10-2030
Accreditation number
2241
Accreditation body
ČIA
Address
Průmyslová 1038, Staré Město, 739 61 Třinec
City
Třinec, Czech Republic
Division
Laboratorium wzorcujące Warsztatów Elektrotechnicznych
Valid until
20-10-2030

What this laboratory calibrates (11)

Calibration principles (7)

Certificate information

Certificate date
20.10.2025

Accreditation scope — calibration items (15)

CMC — lowest stated expanded measurement uncertainty (ILAC-P14, EA-4/02 M); if not stated otherwise, coverage probability approx. 95 % and values without a unit are relative to the measured value. The uncertainty of a specific calibration may be higher.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 DC voltage / DC voltage meters (digital and analogue multimeters and voltmeters) Calibration – electrical quantities
0 mV to 10 mV · CMC 0,5 % +20 µV 10 mV to 50 mV · CMC 0,05 % 50 mV to 100 mV · CMC 0,018 % 100 mV to 1 000 V · CMC 0,012 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a standard calibrator or by comparison with a standard multimeter KPM 1, KPM 3
2 DC voltage / DC voltage sources (sources and calibrators) Calibration – electrical quantities
0 mV to 10 mV · CMC 0,5 % +20 µV 10 mV to 50 mV · CMC 0,05 % 50 mV to 100 mV · CMC 0,018 % 100 mV to 1 000 V · CMC 0,012 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter KPM 1, KPM 3
3 AC voltage / AC voltage meters (digital and analogue multimeters and voltmeters) Calibration – electrical quantities
40 Hz to 12 kHz — 10 mV to 50 mV · CMC 0,70 % 40 Hz to 12 kHz — 50 mV to 20 V · CMC 0,30 % 40 Hz to 1 kHz — 20 V to 750 V · CMC 0,70 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a standard calibrator or by comparison with a standard multimeter KPM 2, KPM 4
4 AC voltage / AC voltage sources (sources and calibrators) Calibration – electrical quantities
40 Hz to 12 kHz — 10 mV to 50 mV · CMC 0,70 % 40 Hz to 12 kHz — 50 mV to 20 V · CMC 0,30 % 40 Hz to 1 kHz — 20 V to 750 V · CMC 0,70 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter KPM 2, KPM 4
5 DC current / DC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes) Calibration – electrical quantities
0 mA to 10 mA · CMC 0,15 % + 4 µA 10 mA to 100 mA · CMC 0,12 % 100 mA to 1 A · CMC 0,20 % 1 A to 3 A · CMC 0,25 % 3 A to 10 A · CMC 0,30 % 10 A to 20 A · CMC 0,30 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a standard calibrator or by comparison with a standard multimeter KPM 1, KPM 3, KPM 8, KPM 9
6 DC current / DC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes) Calibration – electrical quantities
20 A to 1000 A · CMC 0,65 %
CMC for the field of measured quantity: Electrical quantities
Indirect measurement – measurement of simulated current (standard calibrator with a current coil) KPM 1, KPM 3, KPM 8, KPM 9
7 DC current / DC current sources Calibration – electrical quantities
0 mA to 10 mA · CMC 0,15 % + 4 µA. 10 mA to 100 mA · CMC 0,12 % 100 mA to 1 A · CMC 0,20 % 1 A to 3 A · CMC 0,25 % 3 A to 10 A · CMC 0,30 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter KPM 1, KPM 3, KPM 8, KPM 9
8 AC current / AC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes, installation testers) Calibration – electrical quantities
40 Hz to 1 kHz — 10 µA to 100 µA · CMC 0,60 % 40 Hz to 1 kHz — 0,1 mA to 100 mA · CMC 0,60 % 40 Hz to 1 kHz — 0,1 A to 10 A · CMC 0,65 % 40 Hz to 1 kHz — 10 A to 20 A · CMC 0,65 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a standard calibrator or by comparison with a standard multimeter KPM 2, KPM 4, KPM 7, KPM 8, KPM 9
9 AC current / AC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes, installation testers) Calibration – electrical quantities
40 Hz to 1 kHz — 20 A to 1000 A · CMC 0,95 %
CMC for the field of measured quantity: Electrical quantities
Indirect measurement – measurement of simulated current (standard calibrator with a current coil) KPM 2, KPM 4, KPM 7, KPM 8, KPM 9
10 AC current / current sources Calibration – electrical quantities
40 Hz to 1 kHz — 10 µA to 100 µA · CMC 0,60 % 40 Hz to 1 kHz — 0,1 mA to 100 mA · CMC 0,60 % 40 Hz to 1 kHz — 0,1 A to 10 A · CMC 0,65 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter KPM 2, KPM 4, KPM 8, KPM 9
11 AC current / current sources Calibration – electrical quantities
50 Hz — 10 A to 100 A · CMC 0,95 %
CMC for the field of measured quantity: Electrical quantities
Measurement with a current transformer and a standard multimeter KPM 2, KPM 4, KPM 8, KPM 9
12 DC resistance / ohmmeters Calibration – electrical quantities
0,001 Ω · CMC 0,015 % 0,01 Ω · CMC 0,015 % 0,1 Ω · CMC 0,030 % 1 Ω · CMC 0,015 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement of fixed resistance standards KPM 5
13 DC resistance / ohmmeters Calibration – electrical quantities
0,01 Ω to 0,1 Ω · CMC 0,050 % 0,1 Ω to 1 Ω · CMC 0,060 % 1 Ω to 10 Ω · CMC 0,050 % 10 Ω to 100 Ω · CMC 0,060 % 100 Ω to 1 MΩ · CMC 0,050 % 1 MΩ to 10 MΩ · CMC 0,10 % 10 MΩ to 100 MΩ · CMC 0,50 % 100 MΩ to 10 GΩ · CMC 1,5 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement on a resistance decade KPM 5
14 DC resistance / resistors, calibrators, resistance decades Calibration – electrical quantities
0 Ω to 100 Ω · CMC 0,05 % +20 mΩ 100 Ω to 1 MΩ · CMC 0,05 % 1 MΩ to 10 MΩ · CMC 0,10 % 10 MΩ to 100 MΩ · CMC 1,5 %
CMC for the field of measured quantity: Electrical quantities
Direct measurement with a standard multimeter KPM 6
15 AC resistance / installation testers, ohmmeters Calibration – electrical quantities
0,5 Ω to 100 Ω · CMC 0,11 Ω 100 Ω to 1 kΩ · CMC 0,65 Ω 1 kΩ to 10 kΩ · CMC 6,5 Ω
CMC for the field of measured quantity: Electrical quantities
Measurement of the impedance of a standard resistance decade KPM 6, KPM 7

Reference standards (9)

KPM 1
KPM 2
KPM 3
KPM 4
KPM 5
KPM 6
KPM 7
KPM 8
KPM 9