{"lab":{"_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","address":"Průmyslová 1038, Staré Město, 739 61 Třinec","categories":["metrology"],"city":"Třinec","imported_at":"2026-10-08T12:00:00.000Z","lab_kind":"calibration","location":{"type":"Point","coordinates":[18.65113,49.6861176]},"map_coord":[49.6861176,18.65113],"map_geo":"cai-mapa","methods_count":15,"name":"Strojírny a stavby Třinec, a.s.","parse_status":"parsed","parse_version":5,"pdf_files":[],"scope_summary":"Wzorcowanie przyrządów pomiarowych w dziedzinie wielkości elektrycznych, w zakresie określonym w załączniku do świadectwa.","search_text":"strojírny a stavby třinec, a.s. průmyslová 1038, staré město, 739 61 třinec 2241","source_page_url":"https://www.cai.cz/?subjekt=2241-strojirny-a-stavby-trinec-a-s","status":"active","updated_at":"2026-10-08T12:00:00.000Z","valid_from":"","valid_until":"20-10-2030","website":"www.sas-trinec.cz","certificate_date":"20.10.2025","certificate_no":"526/2025","certificate_replaces":"638/2020 z 24.10.2020","en_official":false,"fields_of_testing":[{"codes":"","pl":"Wzorcowanie przyrządów pomiarowych w dziedzinie wielkości elektrycznych, w zakresie określonym w załączniku do świadectwa.","en":"Calibration of measuring instruments in the field of electrical quantities, to the extent specified in the appendix to this Certificate.","zh":"电学量领域测量仪器的校准，范围见本证书附件。","cs":"Kalibrace měřidel v oboru elektrických veličin, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium wzorcujące Warsztatów Elektrotechnicznych","lab_division_cs":"Kalibrační laboratoř Elektrotechnických dílen","lab_division_en":"Calibration Laboratory of the Electrical Workshops","lab_division_zh":"电工车间校准实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"4c9db34ea2e8c3225352babafdb11e1ad7d0bf7ee140fc5c71cbcc15d0e55e87","source_pdf_url":"https://www.cai.cz/OA/pdf/526_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"b544538b0d426fdcb4b53fb1","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"1","test_object":"Napięcie stałe / przyrządy do pomiaru napięcia stałego (cyfrowe i analogowe multimetry i woltomierze)","test_object_en":"DC voltage / DC voltage meters (digital and analogue multimeters and voltmeters)","test_object_zh":"直流电压 / 直流电压测量仪器（数字和模拟万用表及电压表）","test_object_cs":"Stejnosměrné napětí / měřidla stejnosměrného napětí (digitální a analogové multimetry a voltmetry)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"od 10 mV do 50 mV","cmc":"0,05 %"},{"name":"","range":"od 50 mV do 100 mV","cmc":"0,018 %"},{"name":"","range":"od 100 mV do 1 000 V","cmc":"0,012 %"}],"parameters_en":[{"name":"","range":"0 mV to 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"10 mV to 50 mV","cmc":"0,05 %"},{"name":"","range":"50 mV to 100 mV","cmc":"0,018 %"},{"name":"","range":"100 mV to 1 000 V","cmc":"0,012 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"10 mV 至 50 mV","cmc":"0,05 %"},{"name":"","range":"50 mV 至 100 mV","cmc":"0,018 %"},{"name":"","range":"100 mV 至 1 000 V","cmc":"0,012 %"}],"parameters_cs":[{"name":"","range":"0 mV až 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"10 mV až 50 mV","cmc":"0,05 %"},{"name":"","range":"50 mV až 100 mV","cmc":"0,018 %"},{"name":"","range":"100 mV až 1 000 V","cmc":"0,012 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a standard calibrator or by comparison with a standard multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a standard calibrator or by comparison with a standard multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 10 mV CMC 0,5 % +20 µV\nod 10 mV do 50 mV CMC 0,05 %\nod 50 mV do 100 mV CMC 0,018 %\nod 100 mV do 1 000 V CMC 0,012 %\nPomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","reference":"KPM 1, KPM 3","norm_bases":["KPM 1","KPM 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / przyrządy do pomiaru napięcia stałego (cyfrowe i analogowe multimetry i woltomierze) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym od 0 mV do 10 mV CMC 0,5 % +20 µV od 10 mV do 50 mV CMC 0,05 % od 50 mV do 100 mV CMC 0,018 % od 100 mV do 1 000 V CMC 0,012 % Stejnosměrné napětí / měřidla stejnosměrného napětí (digitální a analogové multimetry a voltmetry) Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem 0 mV až 10 mV CMC 0,5 % +20 µV 10 mV až 50 mV CMC 0,05 % 50 mV až 100 mV CMC 0,018 % 100 mV až 1 000 V CMC 0,012 % KPM 1, KPM 3 Napiecie stale / przyrzady do pomiaru napiecia stalego (cyfrowe i analogowe multimetry i woltomierze) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub przez porownanie z multimetrem wzorcowym od 0 mV do 10 mV CMC 0,5 % +20 µV od 10 mV do 50 mV CMC 0,05 % od 50 mV do 100 mV CMC 0,018 % od 100 mV do 1 000 V CMC 0,012 % Stejnosmerne napeti / meridla stejnosmerneho napeti (digitalni a analogove multimetry a voltmetry) Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnanim s etalonovym multimetrem 0 mV az 10 mV CMC 0,5 % +20 µV 10 mV az 50 mV CMC 0,05 % 50 mV az 100 mV CMC 0,018 % 100 mV az 1 000 V CMC 0,012 % KPM 1, KPM 3","search_en":"DC voltage / DC voltage meters (digital and analogue multimeters and voltmeters) Calibration – electrical quantities Direct measurement on a standard calibrator or by comparison with a standard multimeter 0 mV to 10 mV CMC 0,5 % +20 µV 10 mV to 50 mV CMC 0,05 % 50 mV to 100 mV CMC 0,018 % 100 mV to 1 000 V CMC 0,012 % KPM 1, KPM 3","search_zh":"直流电压 / 直流电压测量仪器（数字和模拟万用表及电压表） 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 0 mV 至 10 mV CMC 0,5 % +20 µV 10 mV 至 50 mV CMC 0,05 % 50 mV 至 100 mV CMC 0,018 % 100 mV 至 1 000 V CMC 0,012 % KPM 1, KPM 3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"29c8227dfd43ac39e0340310","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"2","test_object":"Napięcie stałe / źródła napięcia stałego (zasilacze i kalibratory)","test_object_en":"DC voltage / DC voltage sources (sources and calibrators)","test_object_zh":"直流电压 / 直流电压源（电源和校准器）","test_object_cs":"Stejnosměrné napětí / zdroje stejnosměrného napětí (zdroje a kalibrátory)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mV do 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"od 10 mV do 50 mV","cmc":"0,05 %"},{"name":"","range":"od 50 mV do 100 mV","cmc":"0,018 %"},{"name":"","range":"od 100 mV do 1 000 V","cmc":"0,012 %"}],"parameters_en":[{"name":"","range":"0 mV to 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"10 mV to 50 mV","cmc":"0,05 %"},{"name":"","range":"50 mV to 100 mV","cmc":"0,018 %"},{"name":"","range":"100 mV to 1 000 V","cmc":"0,012 %"}],"parameters_zh":[{"name":"","range":"0 mV 至 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"10 mV 至 50 mV","cmc":"0,05 %"},{"name":"","range":"50 mV 至 100 mV","cmc":"0,018 %"},{"name":"","range":"100 mV 至 1 000 V","cmc":"0,012 %"}],"parameters_cs":[{"name":"","range":"0 mV až 10 mV","cmc":"0,5 % +20 µV"},{"name":"","range":"10 mV až 50 mV","cmc":"0,05 %"},{"name":"","range":"50 mV až 100 mV","cmc":"0,018 %"},{"name":"","range":"100 mV až 1 000 V","cmc":"0,012 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement with a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement with a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mV do 10 mV CMC 0,5 % +20 µV\nod 10 mV do 50 mV CMC 0,05 %\nod 50 mV do 100 mV CMC 0,018 %\nod 100 mV do 1 000 V CMC 0,012 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"KPM 1, KPM 3","norm_bases":["KPM 1","KPM 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie stałe / źródła napięcia stałego (zasilacze i kalibratory) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 mV do 10 mV CMC 0,5 % +20 µV od 10 mV do 50 mV CMC 0,05 % od 50 mV do 100 mV CMC 0,018 % od 100 mV do 1 000 V CMC 0,012 % Stejnosměrné napětí / zdroje stejnosměrného napětí (zdroje a kalibrátory) Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mV až 10 mV CMC 0,5 % +20 µV 10 mV až 50 mV CMC 0,05 % 50 mV až 100 mV CMC 0,018 % 100 mV až 1 000 V CMC 0,012 % KPM 1, KPM 3 Napiecie stale / zrodla napiecia stalego (zasilacze i kalibratory) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 mV do 10 mV CMC 0,5 % +20 µV od 10 mV do 50 mV CMC 0,05 % od 50 mV do 100 mV CMC 0,018 % od 100 mV do 1 000 V CMC 0,012 % Stejnosmerne napeti / zdroje stejnosmerneho napeti (zdroje a kalibratory) Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mV az 10 mV CMC 0,5 % +20 µV 10 mV az 50 mV CMC 0,05 % 50 mV az 100 mV CMC 0,018 % 100 mV az 1 000 V CMC 0,012 % KPM 1, KPM 3","search_en":"DC voltage / DC voltage sources (sources and calibrators) Calibration – electrical quantities Direct measurement with a standard multimeter 0 mV to 10 mV CMC 0,5 % +20 µV 10 mV to 50 mV CMC 0,05 % 50 mV to 100 mV CMC 0,018 % 100 mV to 1 000 V CMC 0,012 % KPM 1, KPM 3","search_zh":"直流电压 / 直流电压源（电源和校准器） 校准 – 电学量 用标准万用表直接测量 0 mV 至 10 mV CMC 0,5 % +20 µV 10 mV 至 50 mV CMC 0,05 % 50 mV 至 100 mV CMC 0,018 % 100 mV 至 1 000 V CMC 0,012 % KPM 1, KPM 3","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"23f30380df2521bf0c47766a","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"3","test_object":"Napięcie przemienne / przyrządy do pomiaru napięcia przemiennego (cyfrowe i analogowe multimetry i woltomierze)","test_object_en":"AC voltage / AC voltage meters (digital and analogue multimeters and voltmeters)","test_object_zh":"交流电压 / 交流电压测量仪器（数字和模拟万用表及电压表）","test_object_cs":"Střídavé napětí/ měřidla střídavého napětí (digitální a analogové multimetry a voltmetry)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 12 kHz","range":"od 10 mV do 50 mV","cmc":"0,70 %"},{"name":"40 Hz do 12 kHz","range":"od 50 mV do 20 V","cmc":"0,30 %"},{"name":"40 Hz do 1 kHz","range":"od 20 V do 750 V","cmc":"0,70 %"}],"parameters_en":[{"name":"40 Hz to 12 kHz","range":"10 mV to 50 mV","cmc":"0,70 %"},{"name":"40 Hz to 12 kHz","range":"50 mV to 20 V","cmc":"0,30 %"},{"name":"40 Hz to 1 kHz","range":"20 V to 750 V","cmc":"0,70 %"}],"parameters_zh":[{"name":"40 Hz 至 12 kHz","range":"10 mV 至 50 mV","cmc":"0,70 %"},{"name":"40 Hz 至 12 kHz","range":"50 mV 至 20 V","cmc":"0,30 %"},{"name":"40 Hz 至 1 kHz","range":"20 V 至 750 V","cmc":"0,70 %"}],"parameters_cs":[{"name":"40 Hz až 12 kHz","range":"10 mV až 50 mV","cmc":"0,70 %"},{"name":"40 Hz až 12 kHz","range":"50 mV až 20 V","cmc":"0,30 %"},{"name":"40 Hz až 1 kHz","range":"20 V až 750 V","cmc":"0,70 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a standard calibrator or by comparison with a standard multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a standard calibrator or by comparison with a standard multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 12 kHz od 10 mV do 50 mV CMC 0,70 %\n40 Hz do 12 kHz od 50 mV do 20 V CMC 0,30 %\n40 Hz do 1 kHz od 20 V do 750 V CMC 0,70 %\nPomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","reference":"KPM 2, KPM 4","norm_bases":["KPM 2","KPM 4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / przyrządy do pomiaru napięcia przemiennego (cyfrowe i analogowe multimetry i woltomierze) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym 40 Hz do 12 kHz od 10 mV do 50 mV CMC 0,70 % 40 Hz do 12 kHz od 50 mV do 20 V CMC 0,30 % 40 Hz do 1 kHz od 20 V do 750 V CMC 0,70 % Střídavé napětí/ měřidla střídavého napětí (digitální a analogové multimetry a voltmetry) Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem 40 Hz až 12 kHz 10 mV až 50 mV CMC 0,70 % 40 Hz až 12 kHz 50 mV až 20 V CMC 0,30 % 40 Hz až 1 kHz 20 V až 750 V CMC 0,70 % KPM 2, KPM 4 Napiecie przemienne / przyrzady do pomiaru napiecia przemiennego (cyfrowe i analogowe multimetry i woltomierze) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub przez porownanie z multimetrem wzorcowym 40 Hz do 12 kHz od 10 mV do 50 mV CMC 0,70 % 40 Hz do 12 kHz od 50 mV do 20 V CMC 0,30 % 40 Hz do 1 kHz od 20 V do 750 V CMC 0,70 % Stridave napeti/ meridla stridaveho napeti (digitalni a analogove multimetry a voltmetry) Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnanim s etalonovym multimetrem 40 Hz az 12 kHz 10 mV az 50 mV CMC 0,70 % 40 Hz az 12 kHz 50 mV az 20 V CMC 0,30 % 40 Hz az 1 kHz 20 V az 750 V CMC 0,70 % KPM 2, KPM 4","search_en":"AC voltage / AC voltage meters (digital and analogue multimeters and voltmeters) Calibration – electrical quantities Direct measurement on a standard calibrator or by comparison with a standard multimeter 40 Hz to 12 kHz 10 mV to 50 mV CMC 0,70 % 40 Hz to 12 kHz 50 mV to 20 V CMC 0,30 % 40 Hz to 1 kHz 20 V to 750 V CMC 0,70 % KPM 2, KPM 4","search_zh":"交流电压 / 交流电压测量仪器（数字和模拟万用表及电压表） 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 40 Hz 至 12 kHz 10 mV 至 50 mV CMC 0,70 % 40 Hz 至 12 kHz 50 mV 至 20 V CMC 0,30 % 40 Hz 至 1 kHz 20 V 至 750 V CMC 0,70 % KPM 2, KPM 4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"23523a07ffc6573a3aadce5a","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"4","test_object":"Napięcie przemienne / źródła napięcia przemiennego (zasilacze i kalibratory)","test_object_en":"AC voltage / AC voltage sources (sources and calibrators)","test_object_zh":"交流电压 / 交流电压源（电源和校准器）","test_object_cs":"Střídavé napětí/ zdroje střídavého napětí (zdroje a kalibrátory)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 12 kHz","range":"od 10 mV do 50 mV","cmc":"0,70 %"},{"name":"40 Hz do 12 kHz","range":"od 50 mV do 20 V","cmc":"0,30 %"},{"name":"40 Hz do 1 kHz","range":"od 20 V do 750 V","cmc":"0,70 %"}],"parameters_en":[{"name":"40 Hz to 12 kHz","range":"10 mV to 50 mV","cmc":"0,70 %"},{"name":"40 Hz to 12 kHz","range":"50 mV to 20 V","cmc":"0,30 %"},{"name":"40 Hz to 1 kHz","range":"20 V to 750 V","cmc":"0,70 %"}],"parameters_zh":[{"name":"40 Hz 至 12 kHz","range":"10 mV 至 50 mV","cmc":"0,70 %"},{"name":"40 Hz 至 12 kHz","range":"50 mV 至 20 V","cmc":"0,30 %"},{"name":"40 Hz 至 1 kHz","range":"20 V 至 750 V","cmc":"0,70 %"}],"parameters_cs":[{"name":"40 Hz až 12 kHz","range":"10 mV až 50 mV","cmc":"0,70 %"},{"name":"40 Hz až 12 kHz","range":"50 mV až 20 V","cmc":"0,30 %"},{"name":"40 Hz až 1 kHz","range":"20 V až 750 V","cmc":"0,70 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement with a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement with a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 12 kHz od 10 mV do 50 mV CMC 0,70 %\n40 Hz do 12 kHz od 50 mV do 20 V CMC 0,30 %\n40 Hz do 1 kHz od 20 V do 750 V CMC 0,70 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"KPM 2, KPM 4","norm_bases":["KPM 2","KPM 4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Napięcie przemienne / źródła napięcia przemiennego (zasilacze i kalibratory) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 40 Hz do 12 kHz od 10 mV do 50 mV CMC 0,70 % 40 Hz do 12 kHz od 50 mV do 20 V CMC 0,30 % 40 Hz do 1 kHz od 20 V do 750 V CMC 0,70 % Střídavé napětí/ zdroje střídavého napětí (zdroje a kalibrátory) Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 40 Hz až 12 kHz 10 mV až 50 mV CMC 0,70 % 40 Hz až 12 kHz 50 mV až 20 V CMC 0,30 % 40 Hz až 1 kHz 20 V až 750 V CMC 0,70 % KPM 2, KPM 4 Napiecie przemienne / zrodla napiecia przemiennego (zasilacze i kalibratory) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 40 Hz do 12 kHz od 10 mV do 50 mV CMC 0,70 % 40 Hz do 12 kHz od 50 mV do 20 V CMC 0,30 % 40 Hz do 1 kHz od 20 V do 750 V CMC 0,70 % Stridave napeti/ zdroje stridaveho napeti (zdroje a kalibratory) Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 40 Hz az 12 kHz 10 mV az 50 mV CMC 0,70 % 40 Hz az 12 kHz 50 mV az 20 V CMC 0,30 % 40 Hz az 1 kHz 20 V az 750 V CMC 0,70 % KPM 2, KPM 4","search_en":"AC voltage / AC voltage sources (sources and calibrators) Calibration – electrical quantities Direct measurement with a standard multimeter 40 Hz to 12 kHz 10 mV to 50 mV CMC 0,70 % 40 Hz to 12 kHz 50 mV to 20 V CMC 0,30 % 40 Hz to 1 kHz 20 V to 750 V CMC 0,70 % KPM 2, KPM 4","search_zh":"交流电压 / 交流电压源（电源和校准器） 校准 – 电学量 用标准万用表直接测量 40 Hz 至 12 kHz 10 mV 至 50 mV CMC 0,70 % 40 Hz 至 12 kHz 50 mV 至 20 V CMC 0,30 % 40 Hz 至 1 kHz 20 V 至 750 V CMC 0,70 % KPM 2, KPM 4","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8e26fa0137884834a2c7225f","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"5","test_object":"Prąd stały / przyrządy do pomiaru prądu stałego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe)","test_object_en":"DC current / DC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes)","test_object_zh":"直流电流 / 直流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头）","test_object_cs":"Stejnosměrný proud /měřidla stejnosměrného proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mA do 10 mA","cmc":"0,15 % + 4 µA"},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,12 %"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,20 %"},{"name":"","range":"od 1 A do 3 A","cmc":"0,25 %"},{"name":"","range":"od 3 A do 10 A","cmc":"0,30 %"},{"name":"","range":"od 10 A do 20 A","cmc":"0,30 %"}],"parameters_en":[{"name":"","range":"0 mA to 10 mA","cmc":"0,15 % + 4 µA"},{"name":"","range":"10 mA to 100 mA","cmc":"0,12 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,20 %"},{"name":"","range":"1 A to 3 A","cmc":"0,25 %"},{"name":"","range":"3 A to 10 A","cmc":"0,30 %"},{"name":"","range":"10 A to 20 A","cmc":"0,30 %"}],"parameters_zh":[{"name":"","range":"0 mA 至 10 mA","cmc":"0,15 % + 4 µA"},{"name":"","range":"10 mA 至 100 mA","cmc":"0,12 %"},{"name":"","range":"100 mA 至 1 A","cmc":"0,20 %"},{"name":"","range":"1 A 至 3 A","cmc":"0,25 %"},{"name":"","range":"3 A 至 10 A","cmc":"0,30 %"},{"name":"","range":"10 A 至 20 A","cmc":"0,30 %"}],"parameters_cs":[{"name":"","range":"0 mA až 10 mA","cmc":"0,15 % + 4 µA"},{"name":"","range":"10 mA až 100 mA","cmc":"0,12 %"},{"name":"","range":"100 mA až 1 A","cmc":"0,20 %"},{"name":"","range":"1 A až 3 A","cmc":"0,25 %"},{"name":"","range":"3 A až 10 A","cmc":"0,30 %"},{"name":"","range":"10 A až 20 A","cmc":"0,30 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a standard calibrator or by comparison with a standard multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a standard calibrator or by comparison with a standard multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mA do 10 mA CMC 0,15 % + 4 µA\nod 10 mA do 100 mA CMC 0,12 %\nod 100 mA do 1 A CMC 0,20 %\nod 1 A do 3 A CMC 0,25 %\nod 3 A do 10 A CMC 0,30 %\nod 10 A do 20 A CMC 0,30 %\nPomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","reference":"KPM 1, KPM 3, KPM 8, KPM 9","norm_bases":["KPM 1","KPM 3","KPM 8","KPM 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru prądu stałego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym od 0 mA do 10 mA CMC 0,15 % + 4 µA od 10 mA do 100 mA CMC 0,12 % od 100 mA do 1 A CMC 0,20 % od 1 A do 3 A CMC 0,25 % od 3 A do 10 A CMC 0,30 % od 10 A do 20 A CMC 0,30 % Stejnosměrný proud /měřidla stejnosměrného proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy) Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem 0 mA až 10 mA CMC 0,15 % + 4 µA 10 mA až 100 mA CMC 0,12 % 100 mA až 1 A CMC 0,20 % 1 A až 3 A CMC 0,25 % 3 A až 10 A CMC 0,30 % 10 A až 20 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9 Prad staly / przyrzady do pomiaru pradu stalego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cegowy, cegowe sondy pradowe) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub przez porownanie z multimetrem wzorcowym od 0 mA do 10 mA CMC 0,15 % + 4 µA od 10 mA do 100 mA CMC 0,12 % od 100 mA do 1 A CMC 0,20 % od 1 A do 3 A CMC 0,25 % od 3 A do 10 A CMC 0,30 % od 10 A do 20 A CMC 0,30 % Stejnosmerny proud /meridla stejnosmerneho proudu (digitalni a analogove multimetry, ampermetry, klestovy ampermetr a multimetr, klestove proudove sondy) Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnanim s etalonovym multimetrem 0 mA az 10 mA CMC 0,15 % + 4 µA 10 mA az 100 mA CMC 0,12 % 100 mA az 1 A CMC 0,20 % 1 A az 3 A CMC 0,25 % 3 A az 10 A CMC 0,30 % 10 A az 20 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9","search_en":"DC current / DC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes) Calibration – electrical quantities Direct measurement on a standard calibrator or by comparison with a standard multimeter 0 mA to 10 mA CMC 0,15 % + 4 µA 10 mA to 100 mA CMC 0,12 % 100 mA to 1 A CMC 0,20 % 1 A to 3 A CMC 0,25 % 3 A to 10 A CMC 0,30 % 10 A to 20 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9","search_zh":"直流电流 / 直流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头） 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 0 mA 至 10 mA CMC 0,15 % + 4 µA 10 mA 至 100 mA CMC 0,12 % 100 mA 至 1 A CMC 0,20 % 1 A 至 3 A CMC 0,25 % 3 A 至 10 A CMC 0,30 % 10 A 至 20 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c13cc99d26a11ffc2907ea44","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"5","test_object":"Prąd stały / przyrządy do pomiaru prądu stałego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe)","test_object_en":"DC current / DC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes)","test_object_zh":"直流电流 / 直流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头）","test_object_cs":"Stejnosměrný proud /měřidla stejnosměrného proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 20 A do 1000 A","cmc":"0,65 %"}],"parameters_en":[{"name":"","range":"20 A to 1000 A","cmc":"0,65 %"}],"parameters_zh":[{"name":"","range":"20 A 至 1000 A","cmc":"0,65 %"}],"parameters_cs":[{"name":"","range":"20 A až 1000 A","cmc":"0,65 %"}],"technique":"Pomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową)","technique_en":"Indirect measurement – measurement of simulated current (standard calibrator with a current coil)","technique_zh":"间接测量 – 测量模拟电流（带电流线圈的标准校准器）","technique_cs":"Nepřímé měření – měření simulovaného proudu (etalonový kalibrátor s proudovou cívkou)","techniques":["Pomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową)"],"techniques_en":["Indirect measurement – measurement of simulated current (standard calibrator with a current coil)"],"techniques_zh":["间接测量 – 测量模拟电流（带电流线圈的标准校准器）"],"techniques_cs":["Nepřímé měření – měření simulovaného proudu (etalonový kalibrátor s proudovou cívkou)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nod 20 A do 1000 A CMC 0,65 %\nPomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową)","reference":"KPM 1, KPM 3, KPM 8, KPM 9","norm_bases":["KPM 1","KPM 3","KPM 8","KPM 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / przyrządy do pomiaru prądu stałego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe) Wzorcowanie – wielkości elektryczne Pomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową) od 20 A do 1000 A CMC 0,65 % Stejnosměrný proud /měřidla stejnosměrného proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy) Kalibrace – elektrické veličiny Nepřímé měření – měření simulovaného proudu (etalonový kalibrátor s proudovou cívkou) 20 A až 1000 A CMC 0,65 % KPM 1, KPM 3, KPM 8, KPM 9 Prad staly / przyrzady do pomiaru pradu stalego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cegowy, cegowe sondy pradowe) Wzorcowanie – wielkosci elektryczne Pomiar posredni – pomiar pradu symulowanego (kalibrator wzorcowy z cewka pradowa) od 20 A do 1000 A CMC 0,65 % Stejnosmerny proud /meridla stejnosmerneho proudu (digitalni a analogove multimetry, ampermetry, klestovy ampermetr a multimetr, klestove proudove sondy) Kalibrace – elektricke veliciny Neprime mereni – mereni simulovaneho proudu (etalonovy kalibrator s proudovou civkou) 20 A az 1000 A CMC 0,65 % KPM 1, KPM 3, KPM 8, KPM 9","search_en":"DC current / DC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes) Calibration – electrical quantities Indirect measurement – measurement of simulated current (standard calibrator with a current coil) 20 A to 1000 A CMC 0,65 % KPM 1, KPM 3, KPM 8, KPM 9","search_zh":"直流电流 / 直流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头） 校准 – 电学量 间接测量 – 测量模拟电流（带电流线圈的标准校准器） 20 A 至 1000 A CMC 0,65 % KPM 1, KPM 3, KPM 8, KPM 9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6f603201b806d0265f75600","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"6","test_object":"Prąd stały / źródła prądu stałego","test_object_en":"DC current / DC current sources","test_object_zh":"直流电流 / 直流电流源","test_object_cs":"Stejnosměrný proud / zdroje stejnosměrného proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 mA do 10 mA","cmc":"0,15 % + 4 µA."},{"name":"","range":"od 10 mA do 100 mA","cmc":"0,12 %"},{"name":"","range":"od 100 mA do 1 A","cmc":"0,20 %"},{"name":"","range":"od 1 A do 3 A","cmc":"0,25 %"},{"name":"","range":"od 3 A do 10 A","cmc":"0,30 %"}],"parameters_en":[{"name":"","range":"0 mA to 10 mA","cmc":"0,15 % + 4 µA."},{"name":"","range":"10 mA to 100 mA","cmc":"0,12 %"},{"name":"","range":"100 mA to 1 A","cmc":"0,20 %"},{"name":"","range":"1 A to 3 A","cmc":"0,25 %"},{"name":"","range":"3 A to 10 A","cmc":"0,30 %"}],"parameters_zh":[{"name":"","range":"0 mA 至 10 mA","cmc":"0,15 % + 4 µA."},{"name":"","range":"10 mA 至 100 mA","cmc":"0,12 %"},{"name":"","range":"100 mA 至 1 A","cmc":"0,20 %"},{"name":"","range":"1 A 至 3 A","cmc":"0,25 %"},{"name":"","range":"3 A 至 10 A","cmc":"0,30 %"}],"parameters_cs":[{"name":"","range":"0 mA až 10 mA","cmc":"0,15 % + 4 µA."},{"name":"","range":"10 mA až 100 mA","cmc":"0,12 %"},{"name":"","range":"100 mA až 1 A","cmc":"0,20 %"},{"name":"","range":"1 A až 3 A","cmc":"0,25 %"},{"name":"","range":"3 A až 10 A","cmc":"0,30 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement with a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement with a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 mA do 10 mA CMC 0,15 % + 4 µA.\nod 10 mA do 100 mA CMC 0,12 %\nod 100 mA do 1 A CMC 0,20 %\nod 1 A do 3 A CMC 0,25 %\nod 3 A do 10 A CMC 0,30 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"KPM 1, KPM 3, KPM 8, KPM 9","norm_bases":["KPM 1","KPM 3","KPM 8","KPM 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd stały / źródła prądu stałego Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 mA do 10 mA CMC 0,15 % + 4 µA. od 10 mA do 100 mA CMC 0,12 % od 100 mA do 1 A CMC 0,20 % od 1 A do 3 A CMC 0,25 % od 3 A do 10 A CMC 0,30 % Stejnosměrný proud / zdroje stejnosměrného proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 mA až 10 mA CMC 0,15 % + 4 µA. 10 mA až 100 mA CMC 0,12 % 100 mA až 1 A CMC 0,20 % 1 A až 3 A CMC 0,25 % 3 A až 10 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9 Prad staly / zrodla pradu stalego Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 mA do 10 mA CMC 0,15 % + 4 µA. od 10 mA do 100 mA CMC 0,12 % od 100 mA do 1 A CMC 0,20 % od 1 A do 3 A CMC 0,25 % od 3 A do 10 A CMC 0,30 % Stejnosmerny proud / zdroje stejnosmerneho proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 mA az 10 mA CMC 0,15 % + 4 µA. 10 mA az 100 mA CMC 0,12 % 100 mA az 1 A CMC 0,20 % 1 A az 3 A CMC 0,25 % 3 A az 10 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9","search_en":"DC current / DC current sources Calibration – electrical quantities Direct measurement with a standard multimeter 0 mA to 10 mA CMC 0,15 % + 4 µA. 10 mA to 100 mA CMC 0,12 % 100 mA to 1 A CMC 0,20 % 1 A to 3 A CMC 0,25 % 3 A to 10 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9","search_zh":"直流电流 / 直流电流源 校准 – 电学量 用标准万用表直接测量 0 mA 至 10 mA CMC 0,15 % + 4 µA. 10 mA 至 100 mA CMC 0,12 % 100 mA 至 1 A CMC 0,20 % 1 A 至 3 A CMC 0,25 % 3 A 至 10 A CMC 0,30 % KPM 1, KPM 3, KPM 8, KPM 9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75701ce8694c06ef65ce321f","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe, mierniki do badań instalacji elektrycznych)","test_object_en":"AC current / AC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes, installation testers)","test_object_zh":"交流电流 / 交流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头、电气安装检测仪）","test_object_cs":"Střídavý proud / měřidla střídavého proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy, revizní přístroje)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 10 µA do 100 µA","cmc":"0,60 %"},{"name":"40 Hz do 1 kHz","range":"od 0,1 mA do 100 mA","cmc":"0,60 %"},{"name":"40 Hz do 1 kHz","range":"od 0,1 A do 10 A","cmc":"0,65 %"},{"name":"40 Hz do 1 kHz","range":"od 10 A do 20 A","cmc":"0,65 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"10 µA to 100 µA","cmc":"0,60 %"},{"name":"40 Hz to 1 kHz","range":"0,1 mA to 100 mA","cmc":"0,60 %"},{"name":"40 Hz to 1 kHz","range":"0,1 A to 10 A","cmc":"0,65 %"},{"name":"40 Hz to 1 kHz","range":"10 A to 20 A","cmc":"0,65 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"10 µA 至 100 µA","cmc":"0,60 %"},{"name":"40 Hz 至 1 kHz","range":"0,1 mA 至 100 mA","cmc":"0,60 %"},{"name":"40 Hz 至 1 kHz","range":"0,1 A 至 10 A","cmc":"0,65 %"},{"name":"40 Hz 至 1 kHz","range":"10 A 至 20 A","cmc":"0,65 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"10 µA až 100 µA","cmc":"0,60 %"},{"name":"40 Hz až 1 kHz","range":"0,1 mA až 100 mA","cmc":"0,60 %"},{"name":"40 Hz až 1 kHz","range":"0,1 A až 10 A","cmc":"0,65 %"},{"name":"40 Hz až 1 kHz","range":"10 A až 20 A","cmc":"0,65 %"}],"technique":"Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","technique_en":"Direct measurement on a standard calibrator or by comparison with a standard multimeter","technique_zh":"在标准校准器上直接测量或与标准万用表比较","technique_cs":"Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem","techniques":["Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym"],"techniques_en":["Direct measurement on a standard calibrator or by comparison with a standard multimeter"],"techniques_zh":["在标准校准器上直接测量或与标准万用表比较"],"techniques_cs":["Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 10 µA do 100 µA CMC 0,60 %\n40 Hz do 1 kHz od 0,1 mA do 100 mA CMC 0,60 %\n40 Hz do 1 kHz od 0,1 A do 10 A CMC 0,65 %\n40 Hz do 1 kHz od 10 A do 20 A CMC 0,65 %\nPomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym","reference":"KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","norm_bases":["KPM 2","KPM 4","KPM 7","KPM 8","KPM 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe, mierniki do badań instalacji elektrycznych) Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na kalibratorze wzorcowym lub przez porównanie z multimetrem wzorcowym 40 Hz do 1 kHz od 10 µA do 100 µA CMC 0,60 % 40 Hz do 1 kHz od 0,1 mA do 100 mA CMC 0,60 % 40 Hz do 1 kHz od 0,1 A do 10 A CMC 0,65 % 40 Hz do 1 kHz od 10 A do 20 A CMC 0,65 % Střídavý proud / měřidla střídavého proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy, revizní přístroje) Kalibrace – elektrické veličiny Přímé měření na etalonovém kalibrátoru nebo porovnáním s etalonovým multimetrem 40 Hz až 1 kHz 10 µA až 100 µA CMC 0,60 % 40 Hz až 1 kHz 0,1 mA až 100 mA CMC 0,60 % 40 Hz až 1 kHz 0,1 A až 10 A CMC 0,65 % 40 Hz až 1 kHz 10 A až 20 A CMC 0,65 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9 Prad przemienny / przyrzady do pomiaru pradu przemiennego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cegowy, cegowe sondy pradowe, mierniki do badan instalacji elektrycznych) Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na kalibratorze wzorcowym lub przez porownanie z multimetrem wzorcowym 40 Hz do 1 kHz od 10 µA do 100 µA CMC 0,60 % 40 Hz do 1 kHz od 0,1 mA do 100 mA CMC 0,60 % 40 Hz do 1 kHz od 0,1 A do 10 A CMC 0,65 % 40 Hz do 1 kHz od 10 A do 20 A CMC 0,65 % Stridavy proud / meridla stridaveho proudu (digitalni a analogove multimetry, ampermetry, klestovy ampermetr a multimetr, klestove proudove sondy, revizni pristroje) Kalibrace – elektricke veliciny Prime mereni na etalonovem kalibratoru nebo porovnanim s etalonovym multimetrem 40 Hz az 1 kHz 10 µA az 100 µA CMC 0,60 % 40 Hz az 1 kHz 0,1 mA az 100 mA CMC 0,60 % 40 Hz az 1 kHz 0,1 A az 10 A CMC 0,65 % 40 Hz az 1 kHz 10 A az 20 A CMC 0,65 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","search_en":"AC current / AC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes, installation testers) Calibration – electrical quantities Direct measurement on a standard calibrator or by comparison with a standard multimeter 40 Hz to 1 kHz 10 µA to 100 µA CMC 0,60 % 40 Hz to 1 kHz 0,1 mA to 100 mA CMC 0,60 % 40 Hz to 1 kHz 0,1 A to 10 A CMC 0,65 % 40 Hz to 1 kHz 10 A to 20 A CMC 0,65 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","search_zh":"交流电流 / 交流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头、电气安装检测仪） 校准 – 电学量 在标准校准器上直接测量或与标准万用表比较 40 Hz 至 1 kHz 10 µA 至 100 µA CMC 0,60 % 40 Hz 至 1 kHz 0,1 mA 至 100 mA CMC 0,60 % 40 Hz 至 1 kHz 0,1 A 至 10 A CMC 0,65 % 40 Hz 至 1 kHz 10 A 至 20 A CMC 0,65 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"206bf0784850a62c0dcd1f6d","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"7","test_object":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe, mierniki do badań instalacji elektrycznych)","test_object_en":"AC current / AC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes, installation testers)","test_object_zh":"交流电流 / 交流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头、电气安装检测仪）","test_object_cs":"Střídavý proud / měřidla střídavého proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy, revizní přístroje)","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 20 A do 1000 A","cmc":"0,95 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"20 A to 1000 A","cmc":"0,95 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"20 A 至 1000 A","cmc":"0,95 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"20 A až 1000 A","cmc":"0,95 %"}],"technique":"Pomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową)","technique_en":"Indirect measurement – measurement of simulated current (standard calibrator with a current coil)","technique_zh":"间接测量 – 测量模拟电流（带电流线圈的标准校准器）","technique_cs":"Nepřímé měření – měření simulovaného proudu (etalonový kalibrátor s proudovou cívkou)","techniques":["Pomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową)"],"techniques_en":["Indirect measurement – measurement of simulated current (standard calibrator with a current coil)"],"techniques_zh":["间接测量 – 测量模拟电流（带电流线圈的标准校准器）"],"techniques_cs":["Nepřímé měření – měření simulovaného proudu (etalonový kalibrátor s proudovou cívkou)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n40 Hz do 1 kHz od 20 A do 1000 A CMC 0,95 %\nPomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową)","reference":"KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","norm_bases":["KPM 2","KPM 4","KPM 7","KPM 8","KPM 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / przyrządy do pomiaru prądu przemiennego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cęgowy, cęgowe sondy prądowe, mierniki do badań instalacji elektrycznych) Wzorcowanie – wielkości elektryczne Pomiar pośredni – pomiar prądu symulowanego (kalibrator wzorcowy z cewką prądową) 40 Hz do 1 kHz od 20 A do 1000 A CMC 0,95 % Střídavý proud / měřidla střídavého proudu (digitální a analogové multimetry, ampérmetry, klešťový ampérmetr a multimetr, klešťové proudové sondy, revizní přístroje) Kalibrace – elektrické veličiny Nepřímé měření – měření simulovaného proudu (etalonový kalibrátor s proudovou cívkou) 40 Hz až 1 kHz 20 A až 1000 A CMC 0,95 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9 Prad przemienny / przyrzady do pomiaru pradu przemiennego (cyfrowe i analogowe multimetry, amperomierze, amperomierz i multimetr cegowy, cegowe sondy pradowe, mierniki do badan instalacji elektrycznych) Wzorcowanie – wielkosci elektryczne Pomiar posredni – pomiar pradu symulowanego (kalibrator wzorcowy z cewka pradowa) 40 Hz do 1 kHz od 20 A do 1000 A CMC 0,95 % Stridavy proud / meridla stridaveho proudu (digitalni a analogove multimetry, ampermetry, klestovy ampermetr a multimetr, klestove proudove sondy, revizni pristroje) Kalibrace – elektricke veliciny Neprime mereni – mereni simulovaneho proudu (etalonovy kalibrator s proudovou civkou) 40 Hz az 1 kHz 20 A az 1000 A CMC 0,95 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","search_en":"AC current / AC current meters (digital and analogue multimeters, ammeters, clamp ammeter and multimeter, clamp current probes, installation testers) Calibration – electrical quantities Indirect measurement – measurement of simulated current (standard calibrator with a current coil) 40 Hz to 1 kHz 20 A to 1000 A CMC 0,95 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","search_zh":"交流电流 / 交流电流测量仪器（数字和模拟万用表、电流表、钳形电流表和万用表、钳形电流探头、电气安装检测仪） 校准 – 电学量 间接测量 – 测量模拟电流（带电流线圈的标准校准器） 40 Hz 至 1 kHz 20 A 至 1000 A CMC 0,95 % KPM 2, KPM 4, KPM 7, KPM 8, KPM 9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6fb0ff0d0ca799a58531893c","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"8","test_object":"Prąd przemienny / źródła prądu","test_object_en":"AC current / current sources","test_object_zh":"交流电流 / 电流源","test_object_cs":"Střídavý proud / zdroje proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"40 Hz do 1 kHz","range":"od 10 µA do 100 µA","cmc":"0,60 %"},{"name":"40 Hz do 1 kHz","range":"od 0,1 mA do 100 mA","cmc":"0,60 %"},{"name":"40 Hz do 1 kHz","range":"od 0,1 A do 10 A","cmc":"0,65 %"}],"parameters_en":[{"name":"40 Hz to 1 kHz","range":"10 µA to 100 µA","cmc":"0,60 %"},{"name":"40 Hz to 1 kHz","range":"0,1 mA to 100 mA","cmc":"0,60 %"},{"name":"40 Hz to 1 kHz","range":"0,1 A to 10 A","cmc":"0,65 %"}],"parameters_zh":[{"name":"40 Hz 至 1 kHz","range":"10 µA 至 100 µA","cmc":"0,60 %"},{"name":"40 Hz 至 1 kHz","range":"0,1 mA 至 100 mA","cmc":"0,60 %"},{"name":"40 Hz 至 1 kHz","range":"0,1 A 至 10 A","cmc":"0,65 %"}],"parameters_cs":[{"name":"40 Hz až 1 kHz","range":"10 µA až 100 µA","cmc":"0,60 %"},{"name":"40 Hz až 1 kHz","range":"0,1 mA až 100 mA","cmc":"0,60 %"},{"name":"40 Hz až 1 kHz","range":"0,1 A až 10 A","cmc":"0,65 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement with a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement with a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n40 Hz do 1 kHz od 10 µA do 100 µA CMC 0,60 %\n40 Hz do 1 kHz od 0,1 mA do 100 mA CMC 0,60 %\n40 Hz do 1 kHz od 0,1 A do 10 A CMC 0,65 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"KPM 2, KPM 4, KPM 8, KPM 9","norm_bases":["KPM 2","KPM 4","KPM 8","KPM 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym 40 Hz do 1 kHz od 10 µA do 100 µA CMC 0,60 % 40 Hz do 1 kHz od 0,1 mA do 100 mA CMC 0,60 % 40 Hz do 1 kHz od 0,1 A do 10 A CMC 0,65 % Střídavý proud / zdroje proudu Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 40 Hz až 1 kHz 10 µA až 100 µA CMC 0,60 % 40 Hz až 1 kHz 0,1 mA až 100 mA CMC 0,60 % 40 Hz až 1 kHz 0,1 A až 10 A CMC 0,65 % KPM 2, KPM 4, KPM 8, KPM 9 Prad przemienny / zrodla pradu Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym 40 Hz do 1 kHz od 10 µA do 100 µA CMC 0,60 % 40 Hz do 1 kHz od 0,1 mA do 100 mA CMC 0,60 % 40 Hz do 1 kHz od 0,1 A do 10 A CMC 0,65 % Stridavy proud / zdroje proudu Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 40 Hz az 1 kHz 10 µA az 100 µA CMC 0,60 % 40 Hz az 1 kHz 0,1 mA az 100 mA CMC 0,60 % 40 Hz az 1 kHz 0,1 A az 10 A CMC 0,65 % KPM 2, KPM 4, KPM 8, KPM 9","search_en":"AC current / current sources Calibration – electrical quantities Direct measurement with a standard multimeter 40 Hz to 1 kHz 10 µA to 100 µA CMC 0,60 % 40 Hz to 1 kHz 0,1 mA to 100 mA CMC 0,60 % 40 Hz to 1 kHz 0,1 A to 10 A CMC 0,65 % KPM 2, KPM 4, KPM 8, KPM 9","search_zh":"交流电流 / 电流源 校准 – 电学量 用标准万用表直接测量 40 Hz 至 1 kHz 10 µA 至 100 µA CMC 0,60 % 40 Hz 至 1 kHz 0,1 mA 至 100 mA CMC 0,60 % 40 Hz 至 1 kHz 0,1 A 至 10 A CMC 0,65 % KPM 2, KPM 4, KPM 8, KPM 9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e39f6e14e4c890eafde53528","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"8","test_object":"Prąd przemienny / źródła prądu","test_object_en":"AC current / current sources","test_object_zh":"交流电流 / 电流源","test_object_cs":"Střídavý proud / zdroje proudu","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"50 Hz","range":"od 10 A do 100 A","cmc":"0,95 %"}],"parameters_en":[{"name":"50 Hz","range":"10 A to 100 A","cmc":"0,95 %"}],"parameters_zh":[{"name":"50 Hz","range":"10 A 至 100 A","cmc":"0,95 %"}],"parameters_cs":[{"name":"50 Hz","range":"10 A až 100 A","cmc":"0,95 %"}],"technique":"Pomiar przekładnikiem prądowym z multimetrem wzorcowym","technique_en":"Measurement with a current transformer and a standard multimeter","technique_zh":"用电流互感器和标准万用表测量","technique_cs":"Měření proudovým transformátorem s etalonovým multimetrem","techniques":["Pomiar przekładnikiem prądowym z multimetrem wzorcowym"],"techniques_en":["Measurement with a current transformer and a standard multimeter"],"techniques_zh":["用电流互感器和标准万用表测量"],"techniques_cs":["Měření proudovým transformátorem s etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\n50 Hz od 10 A do 100 A CMC 0,95 %\nPomiar przekładnikiem prądowym z multimetrem wzorcowym","reference":"KPM 2, KPM 4, KPM 8, KPM 9","norm_bases":["KPM 2","KPM 4","KPM 8","KPM 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Prąd przemienny / źródła prądu Wzorcowanie – wielkości elektryczne Pomiar przekładnikiem prądowym z multimetrem wzorcowym 50 Hz od 10 A do 100 A CMC 0,95 % Střídavý proud / zdroje proudu Kalibrace – elektrické veličiny Měření proudovým transformátorem s etalonovým multimetrem 50 Hz 10 A až 100 A CMC 0,95 % KPM 2, KPM 4, KPM 8, KPM 9 Prad przemienny / zrodla pradu Wzorcowanie – wielkosci elektryczne Pomiar przekladnikiem pradowym z multimetrem wzorcowym 50 Hz od 10 A do 100 A CMC 0,95 % Stridavy proud / zdroje proudu Kalibrace – elektricke veliciny Mereni proudovym transformatorem s etalonovym multimetrem 50 Hz 10 A az 100 A CMC 0,95 % KPM 2, KPM 4, KPM 8, KPM 9","search_en":"AC current / current sources Calibration – electrical quantities Measurement with a current transformer and a standard multimeter 50 Hz 10 A to 100 A CMC 0,95 % KPM 2, KPM 4, KPM 8, KPM 9","search_zh":"交流电流 / 电流源 校准 – 电学量 用电流互感器和标准万用表测量 50 Hz 10 A 至 100 A CMC 0,95 % KPM 2, KPM 4, KPM 8, KPM 9","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4d2e73990e74a3199ace9e28","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"9","test_object":"Rezystancja przy prądzie stałym / omomierze","test_object_en":"DC resistance / ohmmeters","test_object_zh":"直流电阻 / 欧姆表","test_object_cs":"Stejnosměrný odpor / ohmmetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"0,001 Ω","cmc":"0,015 %"},{"name":"","range":"0,01 Ω","cmc":"0,015 %"},{"name":"","range":"0,1 Ω","cmc":"0,030 %"},{"name":"","range":"1 Ω","cmc":"0,015 %"}],"parameters_en":[{"name":"","range":"0,001 Ω","cmc":"0,015 %"},{"name":"","range":"0,01 Ω","cmc":"0,015 %"},{"name":"","range":"0,1 Ω","cmc":"0,030 %"},{"name":"","range":"1 Ω","cmc":"0,015 %"}],"parameters_zh":[{"name":"","range":"0,001 Ω","cmc":"0,015 %"},{"name":"","range":"0,01 Ω","cmc":"0,015 %"},{"name":"","range":"0,1 Ω","cmc":"0,030 %"},{"name":"","range":"1 Ω","cmc":"0,015 %"}],"parameters_cs":[{"name":"","range":"0,001 Ω","cmc":"0,015 %"},{"name":"","range":"0,01 Ω","cmc":"0,015 %"},{"name":"","range":"0,1 Ω","cmc":"0,030 %"},{"name":"","range":"1 Ω","cmc":"0,015 %"}],"technique":"Pomiar bezpośredni stałych wzorców rezystancji","technique_en":"Direct measurement of fixed resistance standards","technique_zh":"直接测量固定电阻标准器","technique_cs":"Přímé měření fixních odporových etalonů","techniques":["Pomiar bezpośredni stałych wzorców rezystancji"],"techniques_en":["Direct measurement of fixed resistance standards"],"techniques_zh":["直接测量固定电阻标准器"],"techniques_cs":["Přímé měření fixních odporových etalonů"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\n0,001 Ω CMC 0,015 %\n0,01 Ω CMC 0,015 %\n0,1 Ω CMC 0,030 %\n1 Ω CMC 0,015 %\nPomiar bezpośredni stałych wzorców rezystancji","reference":"KPM 5","norm_bases":["KPM 5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / omomierze Wzorcowanie – wielkości elektryczne Pomiar bezpośredni stałych wzorców rezystancji 0,001 Ω CMC 0,015 % 0,01 Ω CMC 0,015 % 0,1 Ω CMC 0,030 % 1 Ω CMC 0,015 % Stejnosměrný odpor / ohmmetry Kalibrace – elektrické veličiny Přímé měření fixních odporových etalonů 0,001 Ω CMC 0,015 % 0,01 Ω CMC 0,015 % 0,1 Ω CMC 0,030 % 1 Ω CMC 0,015 % KPM 5 Rezystancja przy pradzie stalym / omomierze Wzorcowanie – wielkosci elektryczne Pomiar bezposredni stalych wzorcow rezystancji 0,001 Ω CMC 0,015 % 0,01 Ω CMC 0,015 % 0,1 Ω CMC 0,030 % 1 Ω CMC 0,015 % Stejnosmerny odpor / ohmmetry Kalibrace – elektricke veliciny Prime mereni fixnich odporovych etalonu 0,001 Ω CMC 0,015 % 0,01 Ω CMC 0,015 % 0,1 Ω CMC 0,030 % 1 Ω CMC 0,015 % KPM 5","search_en":"DC resistance / ohmmeters Calibration – electrical quantities Direct measurement of fixed resistance standards 0,001 Ω CMC 0,015 % 0,01 Ω CMC 0,015 % 0,1 Ω CMC 0,030 % 1 Ω CMC 0,015 % KPM 5","search_zh":"直流电阻 / 欧姆表 校准 – 电学量 直接测量固定电阻标准器 0,001 Ω CMC 0,015 % 0,01 Ω CMC 0,015 % 0,1 Ω CMC 0,030 % 1 Ω CMC 0,015 % KPM 5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2423a8a474ec868d01e1b955","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"10","test_object":"Rezystancja przy prądzie stałym / omomierze","test_object_en":"DC resistance / ohmmeters","test_object_zh":"直流电阻 / 欧姆表","test_object_cs":"Stejnosměrný odpor / ohmmetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,01 Ω do 0,1 Ω","cmc":"0,050 %"},{"name":"","range":"od 0,1 Ω do 1 Ω","cmc":"0,060 %"},{"name":"","range":"od 1 Ω do 10 Ω","cmc":"0,050 %"},{"name":"","range":"od 10 Ω do 100 Ω","cmc":"0,060 %"},{"name":"","range":"od 100 Ω do 1 MΩ","cmc":"0,050 %"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,10 %"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"0,50 %"},{"name":"","range":"od 100 MΩ do 10 GΩ","cmc":"1,5 %"}],"parameters_en":[{"name":"","range":"0,01 Ω to 0,1 Ω","cmc":"0,050 %"},{"name":"","range":"0,1 Ω to 1 Ω","cmc":"0,060 %"},{"name":"","range":"1 Ω to 10 Ω","cmc":"0,050 %"},{"name":"","range":"10 Ω to 100 Ω","cmc":"0,060 %"},{"name":"","range":"100 Ω to 1 MΩ","cmc":"0,050 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,10 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"0,50 %"},{"name":"","range":"100 MΩ to 10 GΩ","cmc":"1,5 %"}],"parameters_zh":[{"name":"","range":"0,01 Ω 至 0,1 Ω","cmc":"0,050 %"},{"name":"","range":"0,1 Ω 至 1 Ω","cmc":"0,060 %"},{"name":"","range":"1 Ω 至 10 Ω","cmc":"0,050 %"},{"name":"","range":"10 Ω 至 100 Ω","cmc":"0,060 %"},{"name":"","range":"100 Ω 至 1 MΩ","cmc":"0,050 %"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,10 %"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"0,50 %"},{"name":"","range":"100 MΩ 至 10 GΩ","cmc":"1,5 %"}],"parameters_cs":[{"name":"","range":"0,01 Ω až 0,1 Ω","cmc":"0,050 %"},{"name":"","range":"0,1 Ω až 1 Ω","cmc":"0,060 %"},{"name":"","range":"1 Ω až 10 Ω","cmc":"0,050 %"},{"name":"","range":"10 Ω až 100 Ω","cmc":"0,060 %"},{"name":"","range":"100 Ω až 1 MΩ","cmc":"0,050 %"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,10 %"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"0,50 %"},{"name":"","range":"100 MΩ až 10 GΩ","cmc":"1,5 %"}],"technique":"Pomiar bezpośredni na dekadzie rezystancyjnej","technique_en":"Direct measurement on a resistance decade","technique_zh":"在电阻箱上直接测量","technique_cs":"Přímé měření na odporové dekádě","techniques":["Pomiar bezpośredni na dekadzie rezystancyjnej"],"techniques_en":["Direct measurement on a resistance decade"],"techniques_zh":["在电阻箱上直接测量"],"techniques_cs":["Přímé měření na odporové dekádě"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,01 Ω do 0,1 Ω CMC 0,050 %\nod 0,1 Ω do 1 Ω CMC 0,060 %\nod 1 Ω do 10 Ω CMC 0,050 %\nod 10 Ω do 100 Ω CMC 0,060 %\nod 100 Ω do 1 MΩ CMC 0,050 %\nod 1 MΩ do 10 MΩ CMC 0,10 %\nod 10 MΩ do 100 MΩ CMC 0,50 %\nod 100 MΩ do 10 GΩ CMC 1,5 %\nPomiar bezpośredni na dekadzie rezystancyjnej","reference":"KPM 5","norm_bases":["KPM 5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / omomierze Wzorcowanie – wielkości elektryczne Pomiar bezpośredni na dekadzie rezystancyjnej od 0,01 Ω do 0,1 Ω CMC 0,050 % od 0,1 Ω do 1 Ω CMC 0,060 % od 1 Ω do 10 Ω CMC 0,050 % od 10 Ω do 100 Ω CMC 0,060 % od 100 Ω do 1 MΩ CMC 0,050 % od 1 MΩ do 10 MΩ CMC 0,10 % od 10 MΩ do 100 MΩ CMC 0,50 % od 100 MΩ do 10 GΩ CMC 1,5 % Stejnosměrný odpor / ohmmetry Kalibrace – elektrické veličiny Přímé měření na odporové dekádě 0,01 Ω až 0,1 Ω CMC 0,050 % 0,1 Ω až 1 Ω CMC 0,060 % 1 Ω až 10 Ω CMC 0,050 % 10 Ω až 100 Ω CMC 0,060 % 100 Ω až 1 MΩ CMC 0,050 % 1 MΩ až 10 MΩ CMC 0,10 % 10 MΩ až 100 MΩ CMC 0,50 % 100 MΩ až 10 GΩ CMC 1,5 % KPM 5 Rezystancja przy pradzie stalym / omomierze Wzorcowanie – wielkosci elektryczne Pomiar bezposredni na dekadzie rezystancyjnej od 0,01 Ω do 0,1 Ω CMC 0,050 % od 0,1 Ω do 1 Ω CMC 0,060 % od 1 Ω do 10 Ω CMC 0,050 % od 10 Ω do 100 Ω CMC 0,060 % od 100 Ω do 1 MΩ CMC 0,050 % od 1 MΩ do 10 MΩ CMC 0,10 % od 10 MΩ do 100 MΩ CMC 0,50 % od 100 MΩ do 10 GΩ CMC 1,5 % Stejnosmerny odpor / ohmmetry Kalibrace – elektricke veliciny Prime mereni na odporove dekade 0,01 Ω az 0,1 Ω CMC 0,050 % 0,1 Ω az 1 Ω CMC 0,060 % 1 Ω az 10 Ω CMC 0,050 % 10 Ω az 100 Ω CMC 0,060 % 100 Ω az 1 MΩ CMC 0,050 % 1 MΩ az 10 MΩ CMC 0,10 % 10 MΩ az 100 MΩ CMC 0,50 % 100 MΩ az 10 GΩ CMC 1,5 % KPM 5","search_en":"DC resistance / ohmmeters Calibration – electrical quantities Direct measurement on a resistance decade 0,01 Ω to 0,1 Ω CMC 0,050 % 0,1 Ω to 1 Ω CMC 0,060 % 1 Ω to 10 Ω CMC 0,050 % 10 Ω to 100 Ω CMC 0,060 % 100 Ω to 1 MΩ CMC 0,050 % 1 MΩ to 10 MΩ CMC 0,10 % 10 MΩ to 100 MΩ CMC 0,50 % 100 MΩ to 10 GΩ CMC 1,5 % KPM 5","search_zh":"直流电阻 / 欧姆表 校准 – 电学量 在电阻箱上直接测量 0,01 Ω 至 0,1 Ω CMC 0,050 % 0,1 Ω 至 1 Ω CMC 0,060 % 1 Ω 至 10 Ω CMC 0,050 % 10 Ω 至 100 Ω CMC 0,060 % 100 Ω 至 1 MΩ CMC 0,050 % 1 MΩ 至 10 MΩ CMC 0,10 % 10 MΩ 至 100 MΩ CMC 0,50 % 100 MΩ 至 10 GΩ CMC 1,5 % KPM 5","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b40899165d2442e2053404f5","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"11","test_object":"Rezystancja przy prądzie stałym / rezystory, kalibratory, dekady rezystancyjne","test_object_en":"DC resistance / resistors, calibrators, resistance decades","test_object_zh":"直流电阻 / 电阻器、校准器、电阻箱","test_object_cs":"Stejnosměrný odpor / odpory, kalibrátory, odporové dekády","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0 Ω do 100 Ω","cmc":"0,05 % +20 mΩ"},{"name":"","range":"od 100 Ω do 1 MΩ","cmc":"0,05 %"},{"name":"","range":"od 1 MΩ do 10 MΩ","cmc":"0,10 %"},{"name":"","range":"od 10 MΩ do 100 MΩ","cmc":"1,5 %"}],"parameters_en":[{"name":"","range":"0 Ω to 100 Ω","cmc":"0,05 % +20 mΩ"},{"name":"","range":"100 Ω to 1 MΩ","cmc":"0,05 %"},{"name":"","range":"1 MΩ to 10 MΩ","cmc":"0,10 %"},{"name":"","range":"10 MΩ to 100 MΩ","cmc":"1,5 %"}],"parameters_zh":[{"name":"","range":"0 Ω 至 100 Ω","cmc":"0,05 % +20 mΩ"},{"name":"","range":"100 Ω 至 1 MΩ","cmc":"0,05 %"},{"name":"","range":"1 MΩ 至 10 MΩ","cmc":"0,10 %"},{"name":"","range":"10 MΩ 至 100 MΩ","cmc":"1,5 %"}],"parameters_cs":[{"name":"","range":"0 Ω až 100 Ω","cmc":"0,05 % +20 mΩ"},{"name":"","range":"100 Ω až 1 MΩ","cmc":"0,05 %"},{"name":"","range":"1 MΩ až 10 MΩ","cmc":"0,10 %"},{"name":"","range":"10 MΩ až 100 MΩ","cmc":"1,5 %"}],"technique":"Pomiar bezpośredni multimetrem wzorcowym","technique_en":"Direct measurement with a standard multimeter","technique_zh":"用标准万用表直接测量","technique_cs":"Přímé měření etalonovým multimetrem","techniques":["Pomiar bezpośredni multimetrem wzorcowym"],"techniques_en":["Direct measurement with a standard multimeter"],"techniques_zh":["用标准万用表直接测量"],"techniques_cs":["Přímé měření etalonovým multimetrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0 Ω do 100 Ω CMC 0,05 % +20 mΩ\nod 100 Ω do 1 MΩ CMC 0,05 %\nod 1 MΩ do 10 MΩ CMC 0,10 %\nod 10 MΩ do 100 MΩ CMC 1,5 %\nPomiar bezpośredni multimetrem wzorcowym","reference":"KPM 6","norm_bases":["KPM 6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie stałym / rezystory, kalibratory, dekady rezystancyjne Wzorcowanie – wielkości elektryczne Pomiar bezpośredni multimetrem wzorcowym od 0 Ω do 100 Ω CMC 0,05 % +20 mΩ od 100 Ω do 1 MΩ CMC 0,05 % od 1 MΩ do 10 MΩ CMC 0,10 % od 10 MΩ do 100 MΩ CMC 1,5 % Stejnosměrný odpor / odpory, kalibrátory, odporové dekády Kalibrace – elektrické veličiny Přímé měření etalonovým multimetrem 0 Ω až 100 Ω CMC 0,05 % +20 mΩ 100 Ω až 1 MΩ CMC 0,05 % 1 MΩ až 10 MΩ CMC 0,10 % 10 MΩ až 100 MΩ CMC 1,5 % KPM 6 Rezystancja przy pradzie stalym / rezystory, kalibratory, dekady rezystancyjne Wzorcowanie – wielkosci elektryczne Pomiar bezposredni multimetrem wzorcowym od 0 Ω do 100 Ω CMC 0,05 % +20 mΩ od 100 Ω do 1 MΩ CMC 0,05 % od 1 MΩ do 10 MΩ CMC 0,10 % od 10 MΩ do 100 MΩ CMC 1,5 % Stejnosmerny odpor / odpory, kalibratory, odporove dekady Kalibrace – elektricke veliciny Prime mereni etalonovym multimetrem 0 Ω az 100 Ω CMC 0,05 % +20 mΩ 100 Ω az 1 MΩ CMC 0,05 % 1 MΩ az 10 MΩ CMC 0,10 % 10 MΩ az 100 MΩ CMC 1,5 % KPM 6","search_en":"DC resistance / resistors, calibrators, resistance decades Calibration – electrical quantities Direct measurement with a standard multimeter 0 Ω to 100 Ω CMC 0,05 % +20 mΩ 100 Ω to 1 MΩ CMC 0,05 % 1 MΩ to 10 MΩ CMC 0,10 % 10 MΩ to 100 MΩ CMC 1,5 % KPM 6","search_zh":"直流电阻 / 电阻器、校准器、电阻箱 校准 – 电学量 用标准万用表直接测量 0 Ω 至 100 Ω CMC 0,05 % +20 mΩ 100 Ω 至 1 MΩ CMC 0,05 % 1 MΩ 至 10 MΩ CMC 0,10 % 10 MΩ 至 100 MΩ CMC 1,5 % KPM 6","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5048208290673108e090e90b","lab_id":"6ade8b28ff068247617080fb","country":"CZ","accr_number":"2241","accr_body":"ČIA","row_label":"12","test_object":"Rezystancja przy prądzie przemiennym / mierniki do badań instalacji elektrycznych, omomierze","test_object_en":"AC resistance / installation testers, ohmmeters","test_object_zh":"交流电阻 / 电气安装检测仪、欧姆表","test_object_cs":"Střídavý odpor / revizní přístroje, ohmmetry","methodology":"Wzorcowanie – wielkości elektryczne","methodology_en":"Calibration – electrical quantities","methodology_zh":"校准 – 电学量","methodology_cs":"Kalibrace – elektrické veličiny","parameters":[{"name":"","range":"od 0,5 Ω do 100 Ω","cmc":"0,11 Ω"},{"name":"","range":"od 100 Ω do 1 kΩ","cmc":"0,65 Ω"},{"name":"","range":"od 1 kΩ do 10 kΩ","cmc":"6,5 Ω"}],"parameters_en":[{"name":"","range":"0,5 Ω to 100 Ω","cmc":"0,11 Ω"},{"name":"","range":"100 Ω to 1 kΩ","cmc":"0,65 Ω"},{"name":"","range":"1 kΩ to 10 kΩ","cmc":"6,5 Ω"}],"parameters_zh":[{"name":"","range":"0,5 Ω 至 100 Ω","cmc":"0,11 Ω"},{"name":"","range":"100 Ω 至 1 kΩ","cmc":"0,65 Ω"},{"name":"","range":"1 kΩ 至 10 kΩ","cmc":"6,5 Ω"}],"parameters_cs":[{"name":"","range":"0,5 Ω až 100 Ω","cmc":"0,11 Ω"},{"name":"","range":"100 Ω až 1 kΩ","cmc":"0,65 Ω"},{"name":"","range":"1 kΩ až 10 kΩ","cmc":"6,5 Ω"}],"technique":"Pomiar impedancji wzorcowej dekady rezystancyjnej","technique_en":"Measurement of the impedance of a standard resistance decade","technique_zh":"测量标准电阻箱的阻抗","technique_cs":"Měření impedance etalonové odporové dekády","techniques":["Pomiar impedancji wzorcowej dekady rezystancyjnej"],"techniques_en":["Measurement of the impedance of a standard resistance decade"],"techniques_zh":["测量标准电阻箱的阻抗"],"techniques_cs":["Měření impedance etalonové odporové dekády"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wzorcowanie – wielkości elektryczne\nZakres:\nod 0,5 Ω do 100 Ω CMC 0,11 Ω\nod 100 Ω do 1 kΩ CMC 0,65 Ω\nod 1 kΩ do 10 kΩ CMC 6,5 Ω\nPomiar impedancji wzorcowej dekady rezystancyjnej","reference":"KPM 6, KPM 7","norm_bases":["KPM 6","KPM 7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"CMC dla dziedziny wielkości mierzonej: wielkości elektryczne","regulatory_area_en":"CMC for the field of measured quantity: Electrical quantities","regulatory_area_zh":"被测量领域的CMC：电学量","regulatory_area_cs":"CMC pro obor měřené veličiny: Elektrické veličiny","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Rezystancja przy prądzie przemiennym / mierniki do badań instalacji elektrycznych, omomierze Wzorcowanie – wielkości elektryczne Pomiar impedancji wzorcowej dekady rezystancyjnej od 0,5 Ω do 100 Ω CMC 0,11 Ω od 100 Ω do 1 kΩ CMC 0,65 Ω od 1 kΩ do 10 kΩ CMC 6,5 Ω Střídavý odpor / revizní přístroje, ohmmetry Kalibrace – elektrické veličiny Měření impedance etalonové odporové dekády 0,5 Ω až 100 Ω CMC 0,11 Ω 100 Ω až 1 kΩ CMC 0,65 Ω 1 kΩ až 10 kΩ CMC 6,5 Ω KPM 6, KPM 7 Rezystancja przy pradzie przemiennym / mierniki do badan instalacji elektrycznych, omomierze Wzorcowanie – wielkosci elektryczne Pomiar impedancji wzorcowej dekady rezystancyjnej od 0,5 Ω do 100 Ω CMC 0,11 Ω od 100 Ω do 1 kΩ CMC 0,65 Ω od 1 kΩ do 10 kΩ CMC 6,5 Ω Stridavy odpor / revizni pristroje, ohmmetry Kalibrace – elektricke veliciny Mereni impedance etalonove odporove dekady 0,5 Ω az 100 Ω CMC 0,11 Ω 100 Ω az 1 kΩ CMC 0,65 Ω 1 kΩ az 10 kΩ CMC 6,5 Ω KPM 6, KPM 7","search_en":"AC resistance / installation testers, ohmmeters Calibration – electrical quantities Measurement of the impedance of a standard resistance decade 0,5 Ω to 100 Ω CMC 0,11 Ω 100 Ω to 1 kΩ CMC 0,65 Ω 1 kΩ to 10 kΩ CMC 6,5 Ω KPM 6, KPM 7","search_zh":"交流电阻 / 电气安装检测仪、欧姆表 校准 – 电学量 测量标准电阻箱的阻抗 0,5 Ω 至 100 Ω CMC 0,11 Ω 100 Ω 至 1 kΩ CMC 0,65 Ω 1 kΩ 至 10 kΩ CMC 6,5 Ω KPM 6, KPM 7","categories":["metrology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}