🇨🇿 AFIRE s.r.o. PL

ČIA 1747 • Klecany, Czech Republic • 15 methods

ConstructionElectronics & EMC

AFIRE s.r.o. is a laboratory accredited by ČIA under number 1747 (Klecany, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Construction, Electronics & EMC. Test objects include: Building structures, Smoke barriers, Cables, Cables and cable supporting structures and systems, switchboards (u….

At a glance

  • Accreditation number: ČIA 1747
  • Methods in scope: 15
  • Types of test objects: 13
  • City: Klecany, Czech Republic
  • Valid until: 10-10-2029
Accreditation number
1747
Accreditation body
ČIA
Address
U Obalovny 488, 250 67 Klecany
City
Klecany, Czech Republic
Division
Laboratorium Badań Pożarowych AFIRE
Valid until
10-10-2029

What this laboratory tests (13)

Certificate information

Certificate date
10.02.2026

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Building structures Fire resistance tests ČSN EN 1363-1; EN 1363-1
2 Building structures Fire resistance tests ČSN EN 1363-2, mimo kap. 4, 6, 7; EN 1363-2, mimo kap. 4, 6, 7
3 Door, shutter and window assemblies Fire resistance tests ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A
4 Door assemblies Fire resistance tests ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A; ČSN EN 12605:2001, čl. 5.2; EN 12605:2000, čl. 5.2
5 Elements of building hardware Fire resistance tests ČSN EN 1634-2, mimo čl. 6.4; EN 1634-2, mimo čl. 6.4
6 Non-loadbearing walls Fire resistance tests ČSN EN 1364-1; EN 1364-1
7 Non-loadbearing air transfer grilles Fire resistance tests ČSN EN 1364-5; EN 1364-5
8 Penetration seals Fire resistance tests ČSN EN 1366-3; EN 1366-3
9 Linear joint seals Fire resistance tests ČSN EN 1366-4; EN 1366-4
10 Cables and cable supporting structures and systems, switchboards (up to 1 kV) Fire resistance tests ČSN 73 0895
11 Cables Fire resistance tests ČSN EN 50577; EN 50577
12 Light fire storage units, safes Fire resistance tests ČSN EN 15659; EN 15659
13 Smoke barriers Fire resistance tests ČSN EN 12101-1, příloha D; EN 12101-1, příloha D
14 Smoke barriers Smoke control tests ČSN EN 12101-1, příloha C; EN 12101-1, příloha C
15 Doors and shutters Smoke control tests ČSN EN 1634-3; EN 1634-3; ČSN EN 16034, příloha A; EN 16034, příloha A

Reference standards (31)

EN 12101-1, příloha C
EN 12101-1, příloha D
EN 12605:2000, čl. 5.2
EN 1363-1
EN 1363-2, mimo kap. 4, 6, 7
EN 1364-1
EN 1364-5
EN 1366-3
EN 1366-4
EN 15659
EN 16034, příloha A
EN 1634-1+A1
EN 1634-2, mimo čl. 6.4
EN 1634-3
EN 50577
ČSN 73 0895
ČSN EN 12101-1, příloha C
ČSN EN 12101-1, příloha D
ČSN EN 12605:2001, čl. 5.2
ČSN EN 1363-1
ČSN EN 1363-2, mimo kap. 4, 6, 7
ČSN EN 1364-1
ČSN EN 1364-5
ČSN EN 1366-3
ČSN EN 1366-4
ČSN EN 15659
ČSN EN 16034, příloha A
ČSN EN 1634-1+A1
ČSN EN 1634-2, mimo čl. 6.4
ČSN EN 1634-3
ČSN EN 50577

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1747