{"lab":{"_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","address":"U Obalovny 488, 250 67 Klecany","categories":["construction","electronics"],"city":"Klecany","imported_at":"2026-03-08T10:42:44.590Z","methods_count":15,"name":"AFIRE s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1747_62_2026_CS.pdf","1747_62_2026_EN.pdf"],"scope_summary":"Badania odporności ogniowej i dymoszczelności w piecu pionowym, w zakresie określonym w załączniku do świadectwa.","search_text":"afire s.r.o. u obalovny 488, 250 67 klecany other","status":"active","updated_at":"2026-03-08T14:52:15.783Z","valid_from":"","valid_until":"10-10-2029","website":"www.afire.cz","parsed_at":"2026-09-28T12:00:00.000Z","map_coord":[50.17887,14.405938],"map_geo":"nominatim-street","certificate_date":"10.02.2026","certificate_no":"62/2026","certificate_replaces":"593/2025 z 18.11.2025","en_official":true,"fields_of_testing":[{"codes":"","pl":"Badania odporności ogniowej i dymoszczelności w piecu pionowym, w zakresie określonym w załączniku do świadectwa.","en":"Fire resistance tests and smoke control tests in a vertical furnace to the extent as specified in the appendix to this Certificate.","zh":"立式炉耐火性能和防烟性能试验，范围见本证书附件。","cs":"Zkoušky požární odolnosti a kouřotěsnosti ve vertikální peci, vymezené přílohou tohoto osvědčení."}],"flexible_scope":true,"flexible_scope_url":"https://www.afire.cz","has_en":true,"has_zh":true,"lab_division":"Laboratorium Badań Pożarowych AFIRE","lab_division_cs":"Požární zkušební laboratoř AFIRE","lab_division_en":"Fire Testing Laboratory AFIRE","lab_division_zh":"AFIRE消防检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."},{"pl":"Akredytacja do celów notyfikacji horyzontalnej zgodnie z pkt 3 załącznika V do rozporządzenia Parlamentu Europejskiego i Rady (UE) nr 305/2011: 1. Odporność ogniowa – rozporządzenie (UE) nr 305/2011, system 3 – EN 1634-1; EN 1634-2; EN 1634-3; EN 1364-1; EN 1366-3; EN 1366-4. 2. Klasyfikacja ogniowa wyrobów budowlanych – klasyfikacja na podstawie wyników badań odporności ogniowej – rozporządzenie (UE) nr 305/2011, system 3 – EN 13501-2.","en":"Accreditation for the purposes of horizontal notification pursuant to point 3 of Annex V to Regulation (EU) No 305/2011 of the European Parliament and of the Council: 1. Fire resistance – Regulation (EU) No 305/2011 of the European Parliament and of the Council, System 3 – EN 1634-1; EN 1634-2; EN 1634-3; EN 1364-1; EN 1366-3; EN 1366-4. 2. Fire classification of construction products – classification based on fire resistance test results – Regulation (EU) No 305/2011 of the European Parliament and of the Council, System 3 – EN 13501-2.","zh":"根据欧洲议会和理事会（EU）第305/2011号条例附件V第3点进行横向通报的认可：1. 耐火性能 – （EU）第305/2011号条例，体系3 – EN 1634-1；EN 1634-2；EN 1634-3；EN 1364-1；EN 1366-3；EN 1366-4。2. 建筑产品防火分级 – 基于耐火试验结果的分级 – （EU）第305/2011号条例，体系3 – EN 13501-2。","cs":"Akreditace pro účely horizontálního oznámení dle bodu 3., přílohy V, Nařízení Evropského parlamentu a Rady (EU) č. 305/2011: 1. Požární odolnost – Nařízení Evropského parlamentu a Rady (EU) č. 305/2011, systém 3 – EN 1634-1; EN 1634-2; EN 1634-3; EN 1364-1; EN 1366-3; EN 1366-4. 2. Požární klasifikace stavebních výrobků – klasifikace podle výsledků zkoušek požární odolnosti – Nařízení Evropského parlamentu a Rady (EU) č. 305/2011, systém 3 – EN 13501-2."}],"source_lang":"cs","source_pdf_sha256":"4fadcdbcc100091694c86015aca5d7c070785068e74ef5560c83020901aba2d0","source_pdf_url":"https://www.cai.cz/OA/pdf/62_2026_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/62_2026_EN.pdf"},"methods":[{"_id":"aea6273933af5adb409edad5","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"1","test_object":"Konstrukcje budowlane","test_object_en":"Building structures","test_object_zh":"建筑构件","test_object_cs":"Stavební konstrukce","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1363-1; EN 1363-1","norm_bases":["ČSN EN 1363-1","EN 1363-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"A, C, D","outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Konstrukcje budowlane Badanie odporności ogniowej Stavební konstrukce Zkoušení požární odolnosti ČSN EN 1363-1; EN 1363-1 Konstrukcje budowlane Badanie odpornosci ogniowej Stavebni konstrukce Zkouseni pozarni odolnosti CSN EN 1363-1; EN 1363-1","search_en":"Building structures Fire resistance tests ČSN EN 1363-1; EN 1363-1","search_zh":"建筑构件 耐火性能试验 ČSN EN 1363-1; EN 1363-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"808ff7009fa37854cab76850","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"2","test_object":"Konstrukcje budowlane","test_object_en":"Building structures","test_object_zh":"建筑构件","test_object_cs":"Stavební konstrukce","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1363-2, mimo kap. 4, 6, 7; EN 1363-2, mimo kap. 4, 6, 7","norm_bases":["ČSN EN 1363-2, mimo kap. 4, 6, 7","EN 1363-2, mimo kap. 4, 6, 7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"A, C, D","outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Konstrukcje budowlane Badanie odporności ogniowej Stavební konstrukce Zkoušení požární odolnosti ČSN EN 1363-2, mimo kap. 4, 6, 7; EN 1363-2, mimo kap. 4, 6, 7 Konstrukcje budowlane Badanie odpornosci ogniowej Stavebni konstrukce Zkouseni pozarni odolnosti CSN EN 1363-2, mimo kap. 4, 6, 7; EN 1363-2, mimo kap. 4, 6, 7","search_en":"Building structures Fire resistance tests ČSN EN 1363-2, mimo kap. 4, 6, 7; EN 1363-2, mimo kap. 4, 6, 7","search_zh":"建筑构件 耐火性能试验 ČSN EN 1363-2, mimo kap. 4, 6, 7; EN 1363-2, mimo kap. 4, 6, 7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d83d5f61d45d1d24cbcf9455","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"3","test_object":"Zestawy drzwiowe, zamknięć i okien otwieranych","test_object_en":"Door, shutter and window assemblies","test_object_zh":"门、卷帘及可开启窗组件","test_object_cs":"Sestavy dveří, uzávěrů a otevíravých oken","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A","norm_bases":["ČSN EN 1634-1+A1","EN 1634-1+A1","ČSN EN 16034, příloha A","EN 16034, příloha A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Zestawy drzwiowe, zamknięć i okien otwieranych Badanie odporności ogniowej Sestavy dveří, uzávěrů a otevíravých oken Zkoušení požární odolnosti ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A Zestawy drzwiowe, zamkniec i okien otwieranych Badanie odpornosci ogniowej Sestavy dveri, uzaveru a oteviravych oken Zkouseni pozarni odolnosti CSN EN 1634-1+A1; EN 1634-1+A1; CSN EN 16034, priloha A; EN 16034, priloha A","search_en":"Door, shutter and window assemblies Fire resistance tests ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A","search_zh":"门、卷帘及可开启窗组件 耐火性能试验 ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5f2503b95c13911a4cc49e9","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"4","test_object":"Zestawy bram","test_object_en":"Door assemblies","test_object_zh":"大门组件","test_object_cs":"Sestavy vrat","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A; ČSN EN 12605:2001, čl. 5.2; EN 12605:2000, čl. 5.2","norm_bases":["ČSN EN 1634-1+A1","EN 1634-1+A1","ČSN EN 16034, příloha A","EN 16034, příloha A","ČSN EN 12605:2001, čl. 5.2","EN 12605:2000, čl. 5.2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Zestawy bram Badanie odporności ogniowej Sestavy vrat Zkoušení požární odolnosti ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A; ČSN EN 12605:2001, čl. 5.2; EN 12605:2000, čl. 5.2 Zestawy bram Badanie odpornosci ogniowej Sestavy vrat Zkouseni pozarni odolnosti CSN EN 1634-1+A1; EN 1634-1+A1; CSN EN 16034, priloha A; EN 16034, priloha A; CSN EN 12605:2001, cl. 5.2; EN 12605:2000, cl. 5.2","search_en":"Door assemblies Fire resistance tests ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A; ČSN EN 12605:2001, čl. 5.2; EN 12605:2000, čl. 5.2","search_zh":"大门组件 耐火性能试验 ČSN EN 1634-1+A1; EN 1634-1+A1; ČSN EN 16034, příloha A; EN 16034, příloha A; ČSN EN 12605:2001, čl. 5.2; EN 12605:2000, čl. 5.2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"39a3d61bd33c3915588cd6c5","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"5","test_object":"Elementy okuć budowlanych","test_object_en":"Elements of building hardware","test_object_zh":"建筑五金件","test_object_cs":"Prvky stavebního kování","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1634-2, mimo čl. 6.4; EN 1634-2, mimo čl. 6.4","norm_bases":["ČSN EN 1634-2, mimo čl. 6.4","EN 1634-2, mimo čl. 6.4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Elementy okuć budowlanych Badanie odporności ogniowej Prvky stavebního kování Zkoušení požární odolnosti ČSN EN 1634-2, mimo čl. 6.4; EN 1634-2, mimo čl. 6.4 Elementy okuc budowlanych Badanie odpornosci ogniowej Prvky stavebniho kovani Zkouseni pozarni odolnosti CSN EN 1634-2, mimo cl. 6.4; EN 1634-2, mimo cl. 6.4","search_en":"Elements of building hardware Fire resistance tests ČSN EN 1634-2, mimo čl. 6.4; EN 1634-2, mimo čl. 6.4","search_zh":"建筑五金件 耐火性能试验 ČSN EN 1634-2, mimo čl. 6.4; EN 1634-2, mimo čl. 6.4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"caabfe7c53c3a723d589718d","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"6","test_object":"Ściany nienośne","test_object_en":"Non-loadbearing walls","test_object_zh":"非承重墙","test_object_cs":"Nenosné stěny","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1364-1; EN 1364-1","norm_bases":["ČSN EN 1364-1","EN 1364-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Ściany nienośne Badanie odporności ogniowej Nenosné stěny Zkoušení požární odolnosti ČSN EN 1364-1; EN 1364-1 Sciany nienosne Badanie odpornosci ogniowej Nenosne steny Zkouseni pozarni odolnosti CSN EN 1364-1; EN 1364-1","search_en":"Non-loadbearing walls Fire resistance tests ČSN EN 1364-1; EN 1364-1","search_zh":"非承重墙 耐火性能试验 ČSN EN 1364-1; EN 1364-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e3fc8b280b592914fb073693","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"7","test_object":"Nienośne kratki wentylacyjne","test_object_en":"Non-loadbearing air transfer grilles","test_object_zh":"非承重通风格栅","test_object_cs":"Nenosné větrací mřížky","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1364-5; EN 1364-5","norm_bases":["ČSN EN 1364-5","EN 1364-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Nienośne kratki wentylacyjne Badanie odporności ogniowej Nenosné větrací mřížky Zkoušení požární odolnosti ČSN EN 1364-5; EN 1364-5 Nienosne kratki wentylacyjne Badanie odpornosci ogniowej Nenosne vetraci mrizky Zkouseni pozarni odolnosti CSN EN 1364-5; EN 1364-5","search_en":"Non-loadbearing air transfer grilles Fire resistance tests ČSN EN 1364-5; EN 1364-5","search_zh":"非承重通风格栅 耐火性能试验 ČSN EN 1364-5; EN 1364-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2b31fe850732f75f8c0f9b57","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"8","test_object":"Uszczelnienia przejść instalacyjnych","test_object_en":"Penetration seals","test_object_zh":"贯穿封堵","test_object_cs":"Těsnění prostupů","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1366-3; EN 1366-3","norm_bases":["ČSN EN 1366-3","EN 1366-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Uszczelnienia przejść instalacyjnych Badanie odporności ogniowej Těsnění prostupů Zkoušení požární odolnosti ČSN EN 1366-3; EN 1366-3 Uszczelnienia przejsc instalacyjnych Badanie odpornosci ogniowej Tesneni prostupu Zkouseni pozarni odolnosti CSN EN 1366-3; EN 1366-3","search_en":"Penetration seals Fire resistance tests ČSN EN 1366-3; EN 1366-3","search_zh":"贯穿封堵 耐火性能试验 ČSN EN 1366-3; EN 1366-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a9efca36ee0c8fcf907354c2","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"9","test_object":"Uszczelnienia szczelin liniowych","test_object_en":"Linear joint seals","test_object_zh":"线性缝隙密封","test_object_cs":"Těsnění spár","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 1366-4; EN 1366-4","norm_bases":["ČSN EN 1366-4","EN 1366-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Uszczelnienia szczelin liniowych Badanie odporności ogniowej Těsnění spár Zkoušení požární odolnosti ČSN EN 1366-4; EN 1366-4 Uszczelnienia szczelin liniowych Badanie odpornosci ogniowej Tesneni spar Zkouseni pozarni odolnosti CSN EN 1366-4; EN 1366-4","search_en":"Linear joint seals Fire resistance tests ČSN EN 1366-4; EN 1366-4","search_zh":"线性缝隙密封 耐火性能试验 ČSN EN 1366-4; EN 1366-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d95ea49f889ea9b50b41a281","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"10","test_object":"Kable i konstrukcje nośne oraz systemy kablowe, rozdzielnice (do 1 kV)","test_object_en":"Cables and cable supporting structures and systems, switchboards (up to 1 kV)","test_object_zh":"电缆及电缆支撑结构和系统、配电柜（1 kV以下）","test_object_cs":"Kabely a kabelové nosné konstrukce a systémy, rozváděče (do 1 kV)","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN 73 0895","norm_bases":["ČSN 73 0895"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Kable i konstrukcje nośne oraz systemy kablowe, rozdzielnice (do 1 kV) Badanie odporności ogniowej Kabely a kabelové nosné konstrukce a systémy, rozváděče (do 1 kV) Zkoušení požární odolnosti ČSN 73 0895 Kable i konstrukcje nosne oraz systemy kablowe, rozdzielnice (do 1 kV) Badanie odpornosci ogniowej Kabely a kabelove nosne konstrukce a systemy, rozvadece (do 1 kV) Zkouseni pozarni odolnosti CSN 73 0895","search_en":"Cables and cable supporting structures and systems, switchboards (up to 1 kV) Fire resistance tests ČSN 73 0895","search_zh":"电缆及电缆支撑结构和系统、配电柜（1 kV以下） 耐火性能试验 ČSN 73 0895","categories":["construction","electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b13f6ab5b8add4c0bc44329","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"11","test_object":"Kable","test_object_en":"Cables","test_object_zh":"电缆","test_object_cs":"Kabely","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 50577; EN 50577","norm_bases":["ČSN EN 50577","EN 50577"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Kable Badanie odporności ogniowej Kabely Zkoušení požární odolnosti ČSN EN 50577; EN 50577 Kable Badanie odpornosci ogniowej Kabely Zkouseni pozarni odolnosti CSN EN 50577; EN 50577","search_en":"Cables Fire resistance tests ČSN EN 50577; EN 50577","search_zh":"电缆 耐火性能试验 ČSN EN 50577; EN 50577","categories":["construction","electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6c41313a2b8472136d26f6d5","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"12","test_object":"Lekkie szafy ognioodporne, sejfy","test_object_en":"Light fire storage units, safes","test_object_zh":"轻型防火柜、保险柜","test_object_cs":"Lehké ohnivzdorné skříně, trezory","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 15659; EN 15659","norm_bases":["ČSN EN 15659","EN 15659"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Lekkie szafy ognioodporne, sejfy Badanie odporności ogniowej Lehké ohnivzdorné skříně, trezory Zkoušení požární odolnosti ČSN EN 15659; EN 15659 Lekkie szafy ognioodporne, sejfy Badanie odpornosci ogniowej Lehke ohnivzdorne skrine, trezory Zkouseni pozarni odolnosti CSN EN 15659; EN 15659","search_en":"Light fire storage units, safes Fire resistance tests ČSN EN 15659; EN 15659","search_zh":"轻型防火柜、保险柜 耐火性能试验 ČSN EN 15659; EN 15659","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e5616f7ff326b0c92df7c2cf","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"13","test_object":"Przegrody dymowe","test_object_en":"Smoke barriers","test_object_zh":"挡烟垂壁","test_object_cs":"Kouřové zábrany","methodology":"Badanie odporności ogniowej","methodology_en":"Fire resistance tests","methodology_zh":"耐火性能试验","methodology_cs":"Zkoušení požární odolnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności ogniowej","reference":"ČSN EN 12101-1, příloha D; EN 12101-1, příloha D","norm_bases":["ČSN EN 12101-1, příloha D","EN 12101-1, příloha D"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"Procedury/metody badawcze dotyczą wyłącznie badań w ramach nieobciążonych, wyłącznie w pionowym (ściennym) piecu badawczym, przy czasie trwania do 300 minut i temperaturze do 1187 °C","note_en":"The test procedures/methods apply only to tests in unloaded frames, only in a vertical (wall) test furnace and for a duration of up to 300 minutes and up to a temperature of 1,187 °C","note_zh":"试验程序/方法仅适用于非承载框架中的试验，仅限立式（墙式）试验炉，持续时间不超过300分钟，温度不超过1187 °C","note_cs":"Zkušební postupy/metody platí pouze pro zkoušky v nezatěžovacích rámech, pouze ve svislé (stěnové) zkušební peci a v době trvání do 300 minut a do teploty 1187 °C","search_text":"Przegrody dymowe Badanie odporności ogniowej Kouřové zábrany Zkoušení požární odolnosti ČSN EN 12101-1, příloha D; EN 12101-1, příloha D Przegrody dymowe Badanie odpornosci ogniowej Kourove zabrany Zkouseni pozarni odolnosti CSN EN 12101-1, priloha D; EN 12101-1, priloha D","search_en":"Smoke barriers Fire resistance tests ČSN EN 12101-1, příloha D; EN 12101-1, příloha D","search_zh":"挡烟垂壁 耐火性能试验 ČSN EN 12101-1, příloha D; EN 12101-1, příloha D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"978b2cd03e5bee27a2d29cdd","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"14","test_object":"Przegrody dymowe","test_object_en":"Smoke barriers","test_object_zh":"挡烟垂壁","test_object_cs":"Kouřové zábrany","methodology":"Badanie dymoszczelności","methodology_en":"Smoke control tests","methodology_zh":"防烟性能试验","methodology_cs":"Zkoušení kouřotěsnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie dymoszczelności","reference":"ČSN EN 12101-1, příloha C; EN 12101-1, příloha C","norm_bases":["ČSN EN 12101-1, příloha C","EN 12101-1, příloha C"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody dymowe Badanie dymoszczelności Kouřové zábrany Zkoušení kouřotěsnosti ČSN EN 12101-1, příloha C; EN 12101-1, příloha C Przegrody dymowe Badanie dymoszczelnosci Kourove zabrany Zkouseni kourotesnosti CSN EN 12101-1, priloha C; EN 12101-1, priloha C","search_en":"Smoke barriers Smoke control tests ČSN EN 12101-1, příloha C; EN 12101-1, příloha C","search_zh":"挡烟垂壁 防烟性能试验 ČSN EN 12101-1, příloha C; EN 12101-1, příloha C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"17f629107c7d1241b607e723","lab_id":"69ad52a4de79e566650fd584","country":"CZ","accr_number":"1747","accr_body":"ČIA","row_label":"15","test_object":"Drzwi i zamknięcia otworów","test_object_en":"Doors and shutters","test_object_zh":"门和洞口封闭件","test_object_cs":"Dveře a uzávěry otvorů","methodology":"Badanie dymoszczelności","methodology_en":"Smoke control tests","methodology_zh":"防烟性能试验","methodology_cs":"Zkoušení kouřotěsnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie dymoszczelności","reference":"ČSN EN 1634-3; EN 1634-3; ČSN EN 16034, příloha A; EN 16034, příloha A","norm_bases":["ČSN EN 1634-3","EN 1634-3","ČSN EN 16034, příloha A","EN 16034, příloha A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":true,"flexibility":"A, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Drzwi i zamknięcia otworów Badanie dymoszczelności Dveře a uzávěry otvorů Zkoušení kouřotěsnosti ČSN EN 1634-3; EN 1634-3; ČSN EN 16034, příloha A; EN 16034, příloha A Drzwi i zamkniecia otworow Badanie dymoszczelnosci Dvere a uzavery otvoru Zkouseni kourotesnosti CSN EN 1634-3; EN 1634-3; CSN EN 16034, priloha A; EN 16034, priloha A","search_en":"Doors and shutters Smoke control tests ČSN EN 1634-3; EN 1634-3; ČSN EN 16034, příloha A; EN 16034, příloha A","search_zh":"门和洞口封闭件 防烟性能试验 ČSN EN 1634-3; EN 1634-3; ČSN EN 16034, příloha A; EN 16034, příloha A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}