🇨🇿 Masarykova univerzita PL
EnvironmentFood & beverages
Masarykova univerzita is a laboratory accredited by ČIA under number 1666 (Brno, Czech Republic). Its accreditation scope covers 17 test methods in the following areas: Environment, Food & beverages. Test objects include: Outdoor and indoor air, Food and feed, Blood serum, plasma, Blood serum, plasma, and breast milk. Most frequently used techniques: isotope dilution method HRGC-HRMS, isotope dilution method GC-MS/MS, isotope dilution method LC-MS/MS.
At a glance
- Accreditation number: ČIA 1666
- Methods in scope: 17
- Types of test objects: 12
- Techniques used: 7
- City: Brno, Czech Republic
- Valid until: 17-03-2027
- Accreditation number
- 1666
- Accreditation body
- ČIA
- Address
- Kamenice 753/5, budova A29, 625 00 Brno
- City
- Brno, Czech Republic
- Division
- RECETOX: Laboratoria Analizy Śladowej
- Valid until
- 17-03-2027
What this laboratory tests (12)
- Outdoor and indoor air — 5 methods
- Food and feed — 2 methods
- Blood serum, plasma — 1 method
- Blood serum, plasma, and breast milk — 1 method
- Cell tissues and breast milk — 1 method
- Soil — 1 method
- Soils, food, feed, biological material of animal and plant origin — 1 method
- Soils, sediments, ash, moss, and needles — 1 method
- Surface, drinking and sea water — 1 method
- Urine — 1 method
- Whole blood and its components (serum, plasma) and urine — 1 method
- Whole blood and its components (serum, plasma), urine, breast milk, hair, soils, sediments, fly ash, moss, and needles — 1 method
Analytical techniques used (7)
- isotope dilution method HRGC-HRMS — 4 methods
- isotope dilution method GC-MS/MS — 3 methods
- isotope dilution method LC-MS/MS — 3 methods
- by gravimetry — 2 methods
- AAS method using the AMA 254 analyzer — 1 method
- GC-MS/MS method — 1 method
- ICP-MS method — 1 method
Certificate information
- Certificate date
- 10.10.2024
Accreditation scope — test methods (17)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Outdoor and indoor air | Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS Regulated area: Tests |
isotope dilution method HRGC-HRMS | SOP-LSA-031 mimo kap. 3 bod b až o (EPA Method 1613B; ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4) | |
| 2 | Soils, sediments, ash, moss, and needles | Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS Regulated area: Tests |
isotope dilution method HRGC-HRMS | SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614) | |
| 3 | Food and feed | Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS Regulated area: Tests |
isotope dilution method HRGC-HRMS | SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o, (EPA Method 1613B; ČSN EN 1528-1; ČSN EN 1528-2; ČSN EN 1528-3; ČSN EN 1528-4) | |
| 4 | Cell tissues and breast milk | Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS Regulated area: Tests |
isotope dilution method HRGC-HRMS | SOP-LSA-031 mimo kap. 3 bod a až n (EPA Method 1613B; EPA Method 1668B; EPA Method 1614) | |
| 5 | Outdoor and indoor air | Determination of polycyclic aromatic hydrocarbons (PAH) by GC-MS/MS method Regulated area: Tests |
GC-MS/MS method | SOP-LSA-055 (EPA Method TO-13A) | |
| 6 | Outdoor and indoor air | Determination of indicator polychlorinated biphenyls (PCB), organochlorine pesticides (OCP), and cyclodiene pesticides by isotope dilution method GC-MS/MS Regulated area: Tests |
isotope dilution method GC-MS/MS | SOP-LSA-056 (EPA Method TO-4A) | |
| 7 | Whole blood and its components (serum, plasma) and urine | Determination of trace elements by ICP-MS method Regulated area: Tests |
ICP-MS method | SOP-LSA-807 | |
| 8 | Soils, food, feed, biological material of animal and plant origin | Determination of dry matter by gravimetry and water content (moisture content) by calculation from measured values water content (moisture content) by calculation from measured values (calculated) Regulated area: Tests |
by gravimetry | SOP-LSA-057 (ČSN EN 15934, metoda A; ČSN 46 7092-3) | |
| 9 | Food and feed | Determination of fat by gravimetry Regulated area: Tests |
by gravimetry | SOP-LSA-058 (ČSN EN ISO 2450; ČSN EN ISO 17189; ISO 11085) | |
| 10 | Surface, drinking and sea water | Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS Regulated area: Tests |
isotope dilution method LC-MS/MS | SOP-LSA-510 | |
| 11 | Blood serum, plasma, and breast milk | Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS Regulated area: Tests |
isotope dilution method LC-MS/MS | SOP-LSA-510 | |
| 12 | Whole blood and its components (serum, plasma), urine, breast milk, hair, soils, sediments, fly ash, moss, and needles | Determination of mercury by AAS method using the AMA 254 analyzer Regulated area: Tests |
AAS method using the AMA 254 analyzer | SOP-LSA-808 | |
| 13 | Outdoor and indoor air | Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS Regulated area: Tests |
isotope dilution method GC-MS/MS | SOP-LSA-031 mimo kap. 3, bod b až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614) | |
| 14 | Blood serum, plasma | Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS Regulated area: Tests |
isotope dilution method GC-MS/MS | SOP-LSA-066 | |
| 15 | Urine | Determination of metabolites of phthalates, phthalate alternatives and bisphenols by isotopic dilution method LC-MS/MS Regulated area: Tests |
isotope dilution method LC-MS/MS | SOP-LSA-515 | |
| 16 | Outdoor and indoor air | Air sampling for the determination of persistent organic pollutants (POPs) and metals using solid sorbent (polyurethane foam, filter, polyurethane foam + filter) Regulated area: Sampling |
SOP-LSA-921 (ČSN EN ISO 16000-1; ČSN EN ISO 16000-12; ČSN EN 12341; ČSN EN 14902; ČSN EN 15549; ISO 12884) | ||
| 17 | Soil | Soil sampling for the determination of persistent organic pollutants (POPs) and metals Regulated area: Sampling |
SOP-LSA-985 (ISO 18400; ČSN EN ISO 16133) | ||
Reference standards (41)
EPA Method 1613B
EPA Method 1614
EPA Method 1668B
EPA Method TO-13A
EPA Method TO-4A
ISO 11085
ISO 12884
ISO 18400
SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o
SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o,
SOP-LSA-031 mimo kap. 3 bod a až n
SOP-LSA-031 mimo kap. 3 bod b až o
SOP-LSA-031 mimo kap. 3, bod b až o
SOP-LSA-055
SOP-LSA-056
SOP-LSA-057
SOP-LSA-058
SOP-LSA-066
SOP-LSA-510
SOP-LSA-515
SOP-LSA-807
SOP-LSA-808
SOP-LSA-921
SOP-LSA-985
ČSN 46 7092-3
ČSN EN 12341
ČSN EN 14902
ČSN EN 1528-1
ČSN EN 1528-2
ČSN EN 1528-3
ČSN EN 1528-4
ČSN EN 15549
ČSN EN 15934, metoda A
ČSN EN 1948-2
ČSN EN 1948-3
ČSN EN 1948-4
ČSN EN ISO 16000-1
ČSN EN ISO 16000-12
ČSN EN ISO 16133
ČSN EN ISO 17189
ČSN EN ISO 2450