🇨🇿 Masarykova univerzita PL

ČIA 1666 • Brno, Czech Republic • 17 methods

EnvironmentFood & beverages

Masarykova univerzita is a laboratory accredited by ČIA under number 1666 (Brno, Czech Republic). Its accreditation scope covers 17 test methods in the following areas: Environment, Food & beverages. Test objects include: Outdoor and indoor air, Food and feed, Blood serum, plasma, Blood serum, plasma, and breast milk. Most frequently used techniques: isotope dilution method HRGC-HRMS, isotope dilution method GC-MS/MS, isotope dilution method LC-MS/MS.

At a glance

  • Accreditation number: ČIA 1666
  • Methods in scope: 17
  • Types of test objects: 12
  • Techniques used: 7
  • City: Brno, Czech Republic
  • Valid until: 17-03-2027
Accreditation number
1666
Accreditation body
ČIA
Address
Kamenice 753/5, budova A29, 625 00 Brno
City
Brno, Czech Republic
Division
RECETOX: Laboratoria Analizy Śladowej
Valid until
17-03-2027

What this laboratory tests (12)

Analytical techniques used (7)

Certificate information

Certificate date
10.10.2024

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Outdoor and indoor air Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS
Regulated area: Tests
isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod b až o (EPA Method 1613B; ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4)
2 Soils, sediments, ash, moss, and needles Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS
Regulated area: Tests
isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)
3 Food and feed Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS
Regulated area: Tests
isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o, (EPA Method 1613B; ČSN EN 1528-1; ČSN EN 1528-2; ČSN EN 1528-3; ČSN EN 1528-4)
4 Cell tissues and breast milk Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS
Regulated area: Tests
isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až n (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)
5 Outdoor and indoor air Determination of polycyclic aromatic hydrocarbons (PAH) by GC-MS/MS method
Regulated area: Tests
GC-MS/MS method SOP-LSA-055 (EPA Method TO-13A)
6 Outdoor and indoor air Determination of indicator polychlorinated biphenyls (PCB), organochlorine pesticides (OCP), and cyclodiene pesticides by isotope dilution method GC-MS/MS
Regulated area: Tests
isotope dilution method GC-MS/MS SOP-LSA-056 (EPA Method TO-4A)
7 Whole blood and its components (serum, plasma) and urine Determination of trace elements by ICP-MS method
Regulated area: Tests
ICP-MS method SOP-LSA-807
8 Soils, food, feed, biological material of animal and plant origin Determination of dry matter by gravimetry and water content (moisture content) by calculation from measured values
water content (moisture content) by calculation from measured values (calculated)
Regulated area: Tests
by gravimetry SOP-LSA-057 (ČSN EN 15934, metoda A; ČSN 46 7092-3)
9 Food and feed Determination of fat by gravimetry
Regulated area: Tests
by gravimetry SOP-LSA-058 (ČSN EN ISO 2450; ČSN EN ISO 17189; ISO 11085)
10 Surface, drinking and sea water Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS
Regulated area: Tests
isotope dilution method LC-MS/MS SOP-LSA-510
11 Blood serum, plasma, and breast milk Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS
Regulated area: Tests
isotope dilution method LC-MS/MS SOP-LSA-510
12 Whole blood and its components (serum, plasma), urine, breast milk, hair, soils, sediments, fly ash, moss, and needles Determination of mercury by AAS method using the AMA 254 analyzer
Regulated area: Tests
AAS method using the AMA 254 analyzer SOP-LSA-808
13 Outdoor and indoor air Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS
Regulated area: Tests
isotope dilution method GC-MS/MS SOP-LSA-031 mimo kap. 3, bod b až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)
14 Blood serum, plasma Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS
Regulated area: Tests
isotope dilution method GC-MS/MS SOP-LSA-066
15 Urine Determination of metabolites of phthalates, phthalate alternatives and bisphenols by isotopic dilution method LC-MS/MS
Regulated area: Tests
isotope dilution method LC-MS/MS SOP-LSA-515
16 Outdoor and indoor air Air sampling for the determination of persistent organic pollutants (POPs) and metals using solid sorbent (polyurethane foam, filter, polyurethane foam + filter)
Regulated area: Sampling
SOP-LSA-921 (ČSN EN ISO 16000-1; ČSN EN ISO 16000-12; ČSN EN 12341; ČSN EN 14902; ČSN EN 15549; ISO 12884)
17 Soil Soil sampling for the determination of persistent organic pollutants (POPs) and metals
Regulated area: Sampling
SOP-LSA-985 (ISO 18400; ČSN EN ISO 16133)

Reference standards (41)

EPA Method 1613B
EPA Method 1614
EPA Method 1668B
EPA Method TO-13A
EPA Method TO-4A
ISO 11085
ISO 12884
ISO 18400
SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o
SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o,
SOP-LSA-031 mimo kap. 3 bod a až n
SOP-LSA-031 mimo kap. 3 bod b až o
SOP-LSA-031 mimo kap. 3, bod b až o
SOP-LSA-055
SOP-LSA-056
SOP-LSA-057
SOP-LSA-058
SOP-LSA-066
SOP-LSA-510
SOP-LSA-515
SOP-LSA-807
SOP-LSA-808
SOP-LSA-921
SOP-LSA-985
ČSN 46 7092-3
ČSN EN 12341
ČSN EN 14902
ČSN EN 1528-1
ČSN EN 1528-2
ČSN EN 1528-3
ČSN EN 1528-4
ČSN EN 15549
ČSN EN 15934, metoda A
ČSN EN 1948-2
ČSN EN 1948-3
ČSN EN 1948-4
ČSN EN ISO 16000-1
ČSN EN ISO 16000-12
ČSN EN ISO 16133
ČSN EN ISO 17189
ČSN EN ISO 2450

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1666