{"lab":{"_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","address":"Kamenice 753/5, budova A29, 625 00 Brno","categories":["environment","food"],"city":"Brno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":17,"name":"Masarykova univerzita","parse_status":"parsed","parse_version":5,"pdf_files":["1666_540_2024_CS.pdf","1666_540_2024_EN.pdf"],"scope_summary":"Specjalne analizy śladowe i ultraśladowe substancji organicznych i pierwiastków w próbkach środowiskowych, próbkach biotycznych, żywności i paszach, pobieranie próbek powietrza, gleb i osadów dennych.","search_text":"masarykova univerzita kamenice 753/5, budova a29, 625 00 brno 1666","status":"active","updated_at":"2026-03-08T14:52:14.453Z","valid_from":"","valid_until":"17-03-2027","website":"www.recetox.muni.cz","location":{"type":"Point","coordinates":[16.6068,49.1951]},"map_coord":[49.192244,16.611338],"map_geo":"nominatim-city","certificate_date":"10.10.2024","certificate_no":"540/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Specjalne analizy śladowe i ultraśladowe substancji organicznych i pierwiastków w próbkach środowiskowych, próbkach biotycznych, żywności i paszach, pobieranie próbek powietrza, gleb i osadów dennych.","en":"Special trace and ultratrace analysis of organic compounds and elements in environmental samples, biotic samples, food and feed; sampling of air, soils, and bottom sediments.","zh":"环境样品、生物样品、食品和饲料中有机物和元素的特殊痕量及超痕量分析，空气、土壤和底泥采样。","cs":"Speciální stopové a ultrastopové analýzy organických látek a prvků ve vzorcích životního prostředí, biotických vzorcích, potravinách a krmivech, odběr vzorků ovzduší, půd a dnových sedimentů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"RECETOX: Laboratoria Analizy Śladowej","lab_division_cs":"RECETOX: Laboratoře stopové analýzy","lab_division_en":"RECETOX: Trace Analytical Laboratories","lab_division_zh":"RECETOX：痕量分析实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"GC-MS/MS","pl":"chromatografia gazowa ze spektrometrem mas","en":"Gas Chromatography/Mass Spectrometry","zh":"气相色谱-质谱法","cs":"plynová chromatografie s hmotnostním spektrometrem"},{"abbr":"HRGC-HRMS","pl":"wysokorozdzielcza chromatografia gazowa z wysokorozdzielczym spektrometrem mas","en":"High Resolution Gas Chromatography/High Resolution Mass Spectrometry","zh":"高分辨气相色谱-高分辨质谱法","cs":"vysokorozlišovací plynová chromatografie s vysokorozlišovacím hmotnostním spektrometrem"},{"abbr":"ICP-MS","pl":"spektrometria mas z plazmą wzbudzoną indukcyjnie","en":"Inductively Coupled Plasma Mass Spectrometry","zh":"电感耦合等离子体质谱法","cs":"hmotnostní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"LC-MS/MS","pl":"chromatografia cieczowa ze spektrometrią mas","en":"Liquid Chromatography/Mass Spectrometry","zh":"液相色谱-质谱法","cs":"kapalinová chromatografie s hmotnostní spektrometrií"},{"abbr":"AAS","pl":"atomowa spektrometria absorpcyjna","en":"Atomic Absorption Spectrometry","zh":"原子吸收光谱法","cs":"atomová absorpční spektrometrie"},{"abbr":"AMA","pl":"jednofunkcyjny atomowy spektrometr absorpcyjny","en":"Single-Purpose Atomic Absorption Spectrometer","zh":"专用原子吸收光谱仪","cs":"jednoúčelový atomový absorpční spektrometr"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"c046ef440f1cfe84ade02910f8b39273583f2593f0dc9bf2b0dfd888cd4893f5","source_pdf_url":"https://www.cai.cz/OA/pdf/P540_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P540_2024_EN.pdf"},"methods":[{"_id":"9f5b6c864823da21ad6fba59","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"1","test_object":"Powietrze zewnętrzne i wewnętrzne","test_object_en":"Outdoor and indoor air","test_object_zh":"室外和室内空气","test_object_cs":"Vnější a vnitřní ovzduší","methodology":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS","methodology_en":"Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS","methodology_zh":"同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP）","methodology_cs":"Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego HRGC-HRMS","technique_en":"isotope dilution method HRGC-HRMS","technique_zh":"同位素稀释HRGC-HRMS法","technique_cs":"metodou isotopové zřeďovací HRGC-HRMS","techniques":["metoda rozcieńczenia izotopowego HRGC-HRMS"],"techniques_en":["isotope dilution method HRGC-HRMS"],"techniques_zh":["同位素稀释HRGC-HRMS法"],"techniques_cs":["metodou isotopové zřeďovací HRGC-HRMS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS\nmetoda rozcieńczenia izotopowego HRGC-HRMS","reference":"SOP-LSA-031 mimo kap. 3 bod b až o (EPA Method 1613B; ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4)","norm_bases":["SOP-LSA-031 mimo kap. 3 bod b až o","EPA Method 1613B","ČSN EN 1948-2","ČSN EN 1948-3","ČSN EN 1948-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: polichlorowane dibenzo-p-dioksyny PCDD i polichlorowane dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, obliczanie parametrów TEQ PCDD/F z wyników pomiarów); dioksynopodobne polichlorowane bifenyle PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, obliczanie sum PCB i parametrów TEQ z wyników pomiarów); wskaźnikowe polichlorowane bifenyle PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, obliczanie sum PCB z wyników pomiarów); polibromowane difenyloetery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_en":"Determined analytes: Polychlorinated dibenzo-p-dioxins PCDD and polychlorinated dibenzo-p-furans PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, calculation of TEQ PCDD/F parameters from measured values); dioxin-like polychlorinated biphenyls PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, calculation of PCB sum and TEQ parameters from measured values); indicator polychlorinated biphenyls PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, calculation of PCB sums from measured values); polybrominated diphenyl ethers PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_zh":"测定的分析物：多氯二苯并对二噁英PCDD和多氯二苯并呋喃PCDF（2378-TCDD、12378-PeCDD、123678-HxCDD、123478-HxCDD、234678-HxCDD、1234678-HpCDD、OCDD、2378-TCDF、12378-PeCDF、23478-PeCDF、123678-HxCDF、123478-HxCDF、234678-HxCDF、123789-HxCDF、1234678-HpCDF、1234789-HpCDF、OCDF，由测量值计算TEQ PCDD/F参数）；二噁英类多氯联苯PCB（PCB 77、PCB 81、PCB 105、PCB 114、PCB 118、PCB 123、PCB 126、PCB 156、PCB 157、PCB 167、PCB 169、PCB 189，由测量值计算PCB总量和TEQ参数）；指示性多氯联苯PCB（PCB 28、PCB 52、PCB 101、PCB 118、PCB 138、PCB 153、PCB 180，由测量值计算PCB总量）；多溴二苯醚PBDE（BDE 28、BDE 47、BDE 99、BDE 100、BDE 153、BDE 154、BDE 183、BDE 209）","note_cs":"Stanovované analyty: Polychlorované dibenzo-p-dioxiny PCDD a polychlorované dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, výpočet parametrů TEQ PCDD/F z naměřených hodnot); dioxinům podobné polychlorované bifenyly PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, výpočet sum PCB a parametrů TEQ z naměřených hodnot); indikátorové polychlorované bifenyly PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, výpočet sum PCB z naměřených hodnot); polybromované difenylétery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","search_text":"Powietrze zewnętrzne i wewnętrzne Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS metoda rozcieńczenia izotopowego HRGC-HRMS Vnější a vnitřní ovzduší Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS metodou isotopové zřeďovací HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod b až o (EPA Method 1613B; ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4) Powietrze zewnetrzne i wewnetrzne Oznaczanie wybranych trwalych zanieczyszczen organicznych (TZO/POP) metoda rozcienczenia izotopowego HRGC-HRMS metoda rozcienczenia izotopowego HRGC-HRMS Vnejsi a vnitrni ovzdusi Stanoveni vybranych perzistentnich organickych polutantu (POP) metodou isotopove zredovaci HRGC-HRMS metodou isotopove zredovaci HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod b az o (EPA Method 1613B; CSN EN 1948-2; CSN EN 1948-3; CSN EN 1948-4)","search_en":"Outdoor and indoor air Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod b až o (EPA Method 1613B; ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4)","search_zh":"室外和室内空气 同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP） 同位素稀释HRGC-HRMS法 SOP-LSA-031 mimo kap. 3 bod b až o (EPA Method 1613B; ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"591371b897a8918fedc4e9c4","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"3","test_object":"Gleby, osady denne, popiół lotny, mech, igliwie","test_object_en":"Soils, sediments, ash, moss, and needles","test_object_zh":"土壤、沉积物、飞灰、苔藓、针叶","test_object_cs":"Půdy, sedimenty, popílek, mech, jehličí","methodology":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS","methodology_en":"Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS","methodology_zh":"同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP）","methodology_cs":"Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego HRGC-HRMS","technique_en":"isotope dilution method HRGC-HRMS","technique_zh":"同位素稀释HRGC-HRMS法","technique_cs":"metodou isotopové zřeďovací HRGC-HRMS","techniques":["metoda rozcieńczenia izotopowego HRGC-HRMS"],"techniques_en":["isotope dilution method HRGC-HRMS"],"techniques_zh":["同位素稀释HRGC-HRMS法"],"techniques_cs":["metodou isotopové zřeďovací HRGC-HRMS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS\nmetoda rozcieńczenia izotopowego HRGC-HRMS","reference":"SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","norm_bases":["SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o","EPA Method 1613B","EPA Method 1668B","EPA Method 1614"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: polichlorowane dibenzo-p-dioksyny PCDD i polichlorowane dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, obliczanie parametrów TEQ PCDD/F z wyników pomiarów); dioksynopodobne polichlorowane bifenyle PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, obliczanie sum PCB i parametrów TEQ z wyników pomiarów); wskaźnikowe polichlorowane bifenyle PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, obliczanie sum PCB z wyników pomiarów); polibromowane difenyloetery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_en":"Determined analytes: Polychlorinated dibenzo-p-dioxins PCDD and polychlorinated dibenzo-p-furans PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, calculation of TEQ PCDD/F parameters from measured values); dioxin-like polychlorinated biphenyls PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, calculation of PCB sum and TEQ parameters from measured values); indicator polychlorinated biphenyls PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, calculation of PCB sums from measured values); polybrominated diphenyl ethers PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_zh":"测定的分析物：多氯二苯并对二噁英PCDD和多氯二苯并呋喃PCDF（2378-TCDD、12378-PeCDD、123678-HxCDD、123478-HxCDD、234678-HxCDD、1234678-HpCDD、OCDD、2378-TCDF、12378-PeCDF、23478-PeCDF、123678-HxCDF、123478-HxCDF、234678-HxCDF、123789-HxCDF、1234678-HpCDF、1234789-HpCDF、OCDF，由测量值计算TEQ PCDD/F参数）；二噁英类多氯联苯PCB（PCB 77、PCB 81、PCB 105、PCB 114、PCB 118、PCB 123、PCB 126、PCB 156、PCB 157、PCB 167、PCB 169、PCB 189，由测量值计算PCB总量和TEQ参数）；指示性多氯联苯PCB（PCB 28、PCB 52、PCB 101、PCB 118、PCB 138、PCB 153、PCB 180，由测量值计算PCB总量）；多溴二苯醚PBDE（BDE 28、BDE 47、BDE 99、BDE 100、BDE 153、BDE 154、BDE 183、BDE 209）","note_cs":"Stanovované analyty: Polychlorované dibenzo-p-dioxiny PCDD a polychlorované dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, výpočet parametrů TEQ PCDD/F z naměřených hodnot); dioxinům podobné polychlorované bifenyly PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, výpočet sum PCB a parametrů TEQ z naměřených hodnot); indikátorové polychlorované bifenyly PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, výpočet sum PCB z naměřených hodnot); polybromované difenylétery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","search_text":"Gleby, osady denne, popiół lotny, mech, igliwie Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS metoda rozcieńczenia izotopowego HRGC-HRMS Půdy, sedimenty, popílek, mech, jehličí Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS metodou isotopové zřeďovací HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614) Gleby, osady denne, popiol lotny, mech, igliwie Oznaczanie wybranych trwalych zanieczyszczen organicznych (TZO/POP) metoda rozcienczenia izotopowego HRGC-HRMS metoda rozcienczenia izotopowego HRGC-HRMS Pudy, sedimenty, popilek, mech, jehlici Stanoveni vybranych perzistentnich organickych polutantu (POP) metodou isotopove zredovaci HRGC-HRMS metodou isotopove zredovaci HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a az b a kap. 3 bod g az o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","search_en":"Soils, sediments, ash, moss, and needles Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","search_zh":"土壤、沉积物、飞灰、苔藓、针叶 同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP） 同位素稀释HRGC-HRMS法 SOP-LSA-031 mimo kap. 3 bod a až b a kap. 3 bod g až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c8548379f59d2f5037dadbd1","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"4","test_object":"Żywność i pasze","test_object_en":"Food and feed","test_object_zh":"食品和饲料","test_object_cs":"Potraviny a krmiva","methodology":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS","methodology_en":"Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS","methodology_zh":"同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP）","methodology_cs":"Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego HRGC-HRMS","technique_en":"isotope dilution method HRGC-HRMS","technique_zh":"同位素稀释HRGC-HRMS法","technique_cs":"metodou isotopové zřeďovací HRGC-HRMS","techniques":["metoda rozcieńczenia izotopowego HRGC-HRMS"],"techniques_en":["isotope dilution method HRGC-HRMS"],"techniques_zh":["同位素稀释HRGC-HRMS法"],"techniques_cs":["metodou isotopové zřeďovací HRGC-HRMS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS\nmetoda rozcieńczenia izotopowego HRGC-HRMS","reference":"SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o, (EPA Method 1613B; ČSN EN 1528-1; ČSN EN 1528-2; ČSN EN 1528-3; ČSN EN 1528-4)","norm_bases":["SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o,","EPA Method 1613B","ČSN EN 1528-1","ČSN EN 1528-2","ČSN EN 1528-3","ČSN EN 1528-4"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: polichlorowane dibenzo-p-dioksyny PCDD i polichlorowane dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, obliczanie parametrów TEQ PCDD/F z wyników pomiarów); dioksynopodobne polichlorowane bifenyle PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, obliczanie sum PCB i parametrów TEQ z wyników pomiarów); wskaźnikowe polichlorowane bifenyle PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, obliczanie sum PCB z wyników pomiarów); polibromowane difenyloetery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_en":"Determined analytes: Polychlorinated dibenzo-p-dioxins PCDD and polychlorinated dibenzo-p-furans PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, calculation of TEQ PCDD/F parameters from measured values); dioxin-like polychlorinated biphenyls PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, calculation of PCB sum and TEQ parameters from measured values); indicator polychlorinated biphenyls PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, calculation of PCB sums from measured values); polybrominated diphenyl ethers PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_zh":"测定的分析物：多氯二苯并对二噁英PCDD和多氯二苯并呋喃PCDF（2378-TCDD、12378-PeCDD、123678-HxCDD、123478-HxCDD、234678-HxCDD、1234678-HpCDD、OCDD、2378-TCDF、12378-PeCDF、23478-PeCDF、123678-HxCDF、123478-HxCDF、234678-HxCDF、123789-HxCDF、1234678-HpCDF、1234789-HpCDF、OCDF，由测量值计算TEQ PCDD/F参数）；二噁英类多氯联苯PCB（PCB 77、PCB 81、PCB 105、PCB 114、PCB 118、PCB 123、PCB 126、PCB 156、PCB 157、PCB 167、PCB 169、PCB 189，由测量值计算PCB总量和TEQ参数）；指示性多氯联苯PCB（PCB 28、PCB 52、PCB 101、PCB 118、PCB 138、PCB 153、PCB 180，由测量值计算PCB总量）；多溴二苯醚PBDE（BDE 28、BDE 47、BDE 99、BDE 100、BDE 153、BDE 154、BDE 183、BDE 209）","note_cs":"Stanovované analyty: Polychlorované dibenzo-p-dioxiny PCDD a polychlorované dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, výpočet parametrů TEQ PCDD/F z naměřených hodnot); dioxinům podobné polychlorované bifenyly PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, výpočet sum PCB a parametrů TEQ z naměřených hodnot); indikátorové polychlorované bifenyly PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, výpočet sum PCB z naměřených hodnot); polybromované difenylétery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","search_text":"Żywność i pasze Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS metoda rozcieńczenia izotopowego HRGC-HRMS Potraviny a krmiva Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS metodou isotopové zřeďovací HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o, (EPA Method 1613B; ČSN EN 1528-1; ČSN EN 1528-2; ČSN EN 1528-3; ČSN EN 1528-4) Zywnosc i pasze Oznaczanie wybranych trwalych zanieczyszczen organicznych (TZO/POP) metoda rozcienczenia izotopowego HRGC-HRMS metoda rozcienczenia izotopowego HRGC-HRMS Potraviny a krmiva Stanoveni vybranych perzistentnich organickych polutantu (POP) metodou isotopove zredovaci HRGC-HRMS metodou isotopove zredovaci HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a az f a kap. 3 bod o, (EPA Method 1613B; CSN EN 1528-1; CSN EN 1528-2; CSN EN 1528-3; CSN EN 1528-4)","search_en":"Food and feed Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o, (EPA Method 1613B; ČSN EN 1528-1; ČSN EN 1528-2; ČSN EN 1528-3; ČSN EN 1528-4)","search_zh":"食品和饲料 同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP） 同位素稀释HRGC-HRMS法 SOP-LSA-031 mimo kap. 3 bod a až f a kap. 3 bod o, (EPA Method 1613B; ČSN EN 1528-1; ČSN EN 1528-2; ČSN EN 1528-3; ČSN EN 1528-4)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"648a4bdd6971fc1cb7316daa","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"5","test_object":"Tkanki komórkowe i mleko matki","test_object_en":"Cell tissues and breast milk","test_object_zh":"细胞组织和母乳","test_object_cs":"Buněčné tkáně a mateřské mléko","methodology":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS","methodology_en":"Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS","methodology_zh":"同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP）","methodology_cs":"Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego HRGC-HRMS","technique_en":"isotope dilution method HRGC-HRMS","technique_zh":"同位素稀释HRGC-HRMS法","technique_cs":"metodou isotopové zřeďovací HRGC-HRMS","techniques":["metoda rozcieńczenia izotopowego HRGC-HRMS"],"techniques_en":["isotope dilution method HRGC-HRMS"],"techniques_zh":["同位素稀释HRGC-HRMS法"],"techniques_cs":["metodou isotopové zřeďovací HRGC-HRMS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS\nmetoda rozcieńczenia izotopowego HRGC-HRMS","reference":"SOP-LSA-031 mimo kap. 3 bod a až n (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","norm_bases":["SOP-LSA-031 mimo kap. 3 bod a až n","EPA Method 1613B","EPA Method 1668B","EPA Method 1614"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: polichlorowane dibenzo-p-dioksyny PCDD i polichlorowane dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, obliczanie parametrów TEQ PCDD/F z wyników pomiarów); dioksynopodobne polichlorowane bifenyle PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, obliczanie sum PCB i parametrów TEQ z wyników pomiarów); wskaźnikowe polichlorowane bifenyle PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, obliczanie sum PCB z wyników pomiarów); polibromowane difenyloetery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_en":"Determined analytes: Polychlorinated dibenzo-p-dioxins PCDD and polychlorinated dibenzo-p-furans PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, calculation of TEQ PCDD/F parameters from measured values); dioxin-like polychlorinated biphenyls PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, calculation of PCB sum and TEQ parameters from measured values); indicator polychlorinated biphenyls PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, calculation of PCB sums from measured values); polybrominated diphenyl ethers PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","note_zh":"测定的分析物：多氯二苯并对二噁英PCDD和多氯二苯并呋喃PCDF（2378-TCDD、12378-PeCDD、123678-HxCDD、123478-HxCDD、234678-HxCDD、1234678-HpCDD、OCDD、2378-TCDF、12378-PeCDF、23478-PeCDF、123678-HxCDF、123478-HxCDF、234678-HxCDF、123789-HxCDF、1234678-HpCDF、1234789-HpCDF、OCDF，由测量值计算TEQ PCDD/F参数）；二噁英类多氯联苯PCB（PCB 77、PCB 81、PCB 105、PCB 114、PCB 118、PCB 123、PCB 126、PCB 156、PCB 157、PCB 167、PCB 169、PCB 189，由测量值计算PCB总量和TEQ参数）；指示性多氯联苯PCB（PCB 28、PCB 52、PCB 101、PCB 118、PCB 138、PCB 153、PCB 180，由测量值计算PCB总量）；多溴二苯醚PBDE（BDE 28、BDE 47、BDE 99、BDE 100、BDE 153、BDE 154、BDE 183、BDE 209）","note_cs":"Stanovované analyty: Polychlorované dibenzo-p-dioxiny PCDD a polychlorované dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, výpočet parametrů TEQ PCDD/F z naměřených hodnot); dioxinům podobné polychlorované bifenyly PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, výpočet sum PCB a parametrů TEQ z naměřených hodnot); indikátorové polychlorované bifenyly PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, výpočet sum PCB z naměřených hodnot); polybromované difenylétery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209)","search_text":"Tkanki komórkowe i mleko matki Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego HRGC-HRMS metoda rozcieńczenia izotopowego HRGC-HRMS Buněčné tkáně a mateřské mléko Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací HRGC-HRMS metodou isotopové zřeďovací HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až n (EPA Method 1613B; EPA Method 1668B; EPA Method 1614) Tkanki komorkowe i mleko matki Oznaczanie wybranych trwalych zanieczyszczen organicznych (TZO/POP) metoda rozcienczenia izotopowego HRGC-HRMS metoda rozcienczenia izotopowego HRGC-HRMS Bunecne tkane a materske mleko Stanoveni vybranych perzistentnich organickych polutantu (POP) metodou isotopove zredovaci HRGC-HRMS metodou isotopove zredovaci HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a az n (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","search_en":"Cell tissues and breast milk Determination of persistent organic pollutants (POP) by isotope dilution method HRGC-HRMS isotope dilution method HRGC-HRMS SOP-LSA-031 mimo kap. 3 bod a až n (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","search_zh":"细胞组织和母乳 同位素稀释HRGC-HRMS法测定选定的持久性有机污染物（POP） 同位素稀释HRGC-HRMS法 SOP-LSA-031 mimo kap. 3 bod a až n (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"831dbe3f49fd8f558e03e075","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"6","test_object":"Powietrze zewnętrzne i wewnętrzne","test_object_en":"Outdoor and indoor air","test_object_zh":"室外和室内空气","test_object_cs":"Vnější a vnitřní ovzduší","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA/PAH) metodą GC-MS/MS","methodology_en":"Determination of polycyclic aromatic hydrocarbons (PAH) by GC-MS/MS method","methodology_zh":"GC-MS/MS法测定多环芳烃（PAH）","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků (PAH) metodou GC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda GC-MS/MS","technique_en":"GC-MS/MS method","technique_zh":"GC-MS/MS法","technique_cs":"metodou GC-MS/MS","techniques":["metoda GC-MS/MS"],"techniques_en":["GC-MS/MS method"],"techniques_zh":["GC-MS/MS法"],"techniques_cs":["metodou GC-MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA/PAH) metodą GC-MS/MS\nmetoda GC-MS/MS","reference":"SOP-LSA-055 (EPA Method TO-13A)","norm_bases":["SOP-LSA-055","EPA Method TO-13A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: naftalen, acenaftylen, acenaften, fluoren, fenantren, antracen, fluoranten, piren, benzo(a)antracen, chryzen, benzo(b)fluoranten, benzo(k)fluoranten, benzo(a)piren, indeno(123cd)piren, dibenzo(ah)antracen, benzo(ghi)perylen, bifenyl, reten, benzo(b)fluoren, benzonaftotiofen, benzo(ghi)fluoranten, cyklopenta(cd)piren, trifenylen, benzo(j)fluoranten, benzo(e)piren, perylen, dibenzo(ac)antracen, antantren, koronen) i obliczanie sum WWA z wyników pomiarów","note_en":"Determined analytes: Naphthalene, Acenaphthylene, Acenaphthene, Fluorene, Phenanthrene, Anthracene, Fluoranthene, Pyrene, Benzo(a)anthracene, Chrysene, Benzo(b)fluoranthene, Benzo(k)fluoranthene, Benzo(a)pyrene, Indeno(123cd)pyrene, Dibenzo(ah)anthracene, Benzo(ghi)perylene, Biphenyl, Retene, Benzo(b)fluorene, Benzo-naphtho-thiophene, Benzo(ghi)fluoranthene, Cyclopenta(cd)pyrene, Triphenylene, Benzo(j)fluoranthene, Benzo(e)pyrene, Perylene, Dibenzo(ac)anthracene, Anthanthrene, Coronene) and calculation of the sums of PAH from measured values","note_zh":"测定的分析物：萘、苊烯、苊、芴、菲、蒽、荧蒽、芘、苯并(a)蒽、䓛、苯并(b)荧蒽、苯并(k)荧蒽、苯并(a)芘、茚并(123cd)芘、二苯并(ah)蒽、苯并(ghi)苝、联苯、惹烯、苯并(b)芴、苯并萘并噻吩、苯并(ghi)荧蒽、环戊并(cd)芘、三亚苯、苯并(j)荧蒽、苯并(e)芘、苝、二苯并(ac)蒽、蒽嵌蒽、晕苯）及由测量值计算PAH总量","note_cs":"Stanovované analyty: Naftalen, Acenaftylen, Acenaften, Fluoren, Fenantren, Antracen, Fluoranten, Pyren, Benzo(a)antracen, Chrysen, Benzo(b)fluoranten, Benzo(k)fluoranten, Benzo(a)pyren, Indeno(123cd)pyren, Dibenzo(ah)antracen, Benzo(ghi)perylen, Bifenyl, Reten, Benzo(b)fluoren, Benzo-nafto-thiofen, Benzo(ghi)fluoranten, Cyclopenta(cd)pyren, Trifenylen, Benzo(j)fluoranten, Benzo(e)pyren, Perylen, Dibenzo(ac)antracen, Antantren, Coronen) a výpočet sum PAH z naměřených hodnot","search_text":"Powietrze zewnętrzne i wewnętrzne Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA/PAH) metodą GC-MS/MS metoda GC-MS/MS Vnější a vnitřní ovzduší Stanovení polycyklických aromatických uhlovodíků (PAH) metodou GC-MS/MS metodou GC-MS/MS SOP-LSA-055 (EPA Method TO-13A) Powietrze zewnetrzne i wewnetrzne Oznaczanie wielopierscieniowych weglowodorow aromatycznych (WWA/PAH) metoda GC-MS/MS metoda GC-MS/MS Vnejsi a vnitrni ovzdusi Stanoveni polycyklickych aromatickych uhlovodiku (PAH) metodou GC-MS/MS metodou GC-MS/MS SOP-LSA-055 (EPA Method TO-13A)","search_en":"Outdoor and indoor air Determination of polycyclic aromatic hydrocarbons (PAH) by GC-MS/MS method GC-MS/MS method SOP-LSA-055 (EPA Method TO-13A)","search_zh":"室外和室内空气 GC-MS/MS法测定多环芳烃（PAH） GC-MS/MS法 SOP-LSA-055 (EPA Method TO-13A)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79888de8c4d59fa7755b83d3","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"7","test_object":"Powietrze zewnętrzne i wewnętrzne","test_object_en":"Outdoor and indoor air","test_object_zh":"室外和室内空气","test_object_cs":"Vnější a vnitřní ovzduší","methodology":"Oznaczanie wskaźnikowych polichlorowanych bifenyli (PCB), pestycydów chloroorganicznych (OCP) i pestycydów cyklodienowych metodą rozcieńczenia izotopowego GC-MS/MS","methodology_en":"Determination of indicator polychlorinated biphenyls (PCB), organochlorine pesticides (OCP), and cyclodiene pesticides by isotope dilution method GC-MS/MS","methodology_zh":"同位素稀释GC-MS/MS法测定指示性多氯联苯（PCB）、有机氯农药（OCP）和环二烯类农药","methodology_cs":"Stanovení indikátorových polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP) a cyklodienových pesticidů, metodou isotopově zřeďovací GC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego GC-MS/MS","technique_en":"isotope dilution method GC-MS/MS","technique_zh":"同位素稀释GC-MS/MS法","technique_cs":"metodou isotopově zřeďovací GC-MS/MS","techniques":["metoda rozcieńczenia izotopowego GC-MS/MS"],"techniques_en":["isotope dilution method GC-MS/MS"],"techniques_zh":["同位素稀释GC-MS/MS法"],"techniques_cs":["metodou isotopově zřeďovací GC-MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wskaźnikowych polichlorowanych bifenyli (PCB), pestycydów chloroorganicznych (OCP) i pestycydów cyklodienowych metodą rozcieńczenia izotopowego GC-MS/MS\nmetoda rozcieńczenia izotopowego GC-MS/MS","reference":"SOP-LSA-056 (EPA Method TO-4A)","norm_bases":["SOP-LSA-056","EPA Method TO-4A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: polichlorowane bifenyle PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180), obliczanie sum PCB z wyników pomiarów; heptachlor, epoksyd heptachloru cis- (= egzo, B), epoksyd heptachloru trans- (= endo, A), aldryna, dieldryna, endryna, aldehyd endryny, keton endryny, izodryna, oksychlordan, cis-nonachlor, trans-nonachlor, trans-chlordan (= gamma), cis-chlordan (= alfa), endosulfan I (= alfa), endosulfan II (= beta), siarczan endosulfanu, chlordekon, metoksychlor, mireks, heksachlorocykloheksan HCH (alfa-HCH, beta-HCH, gamma-HCH, delta-HCH, epsilon-HCH), pestycydy (p,p'-DDT, o,p'-DDT, p,p'-DDE, o,p'-DDE, p,p'-DDD, o,p'-DDD), pentachlorobenzen, heksachlorobenzen, obliczanie sum HCH i pestycydów z wyników pomiarów","note_en":"Determined analytes: Polychlorinated biphenyls PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180), calculation of PCB sums from measured values; heptachlor, heptachloroepoxide cis- (= exo, B), heptachloroepoxide trans- (= endo, A), aldrin, dieldrin, endrin, endrin aldehyde, endrin ketone, isodrin, oxychlordane, cis-nonachlor, trans-nonachlor, trans-chlordane (= gama), cis-chlordane (= alfa), endosulfan I (= alpha), endosulfan II (= beta), endosulfan sulfate, chlordecon, methoxychlor, mirex, hexachlorocyclohexane HCH (alpha-HCH, beta-HCH, gamma-HCH, delta-HCH, epsilon-HCH), pesticides (p,p'-DDT, o,p'-DDT, p,p'-DDE, o,p'-DDE, p,p'-DDD, o,p'-DDD), pentachlorobenzene, hexachlorobenzene, calculation of the sums of HCH and pesticides from measured values","note_zh":"测定的分析物：多氯联苯PCB（PCB 28、PCB 52、PCB 101、PCB 118、PCB 138、PCB 153、PCB 180），由测量值计算PCB总量；七氯、顺式环氧七氯（= exo，B）、反式环氧七氯（= endo，A）、艾氏剂、狄氏剂、异狄氏剂、异狄氏剂醛、异狄氏剂酮、异艾氏剂、氧氯丹、顺式九氯、反式九氯、反式氯丹（= γ）、顺式氯丹（= α）、硫丹I（= α）、硫丹II（= β）、硫丹硫酸盐、十氯酮、甲氧滴滴涕、灭蚁灵、六氯环己烷HCH（α-HCH、β-HCH、γ-HCH、δ-HCH、ε-HCH）、农药（p,p'-DDT、o,p'-DDT、p,p'-DDE、o,p'-DDE、p,p'-DDD、o,p'-DDD）、五氯苯、六氯苯，由测量值计算HCH和农药总量","note_cs":"Stanovované analyty: Polychlorované bifenyly PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180), výpočet sum PCB z naměřených hodnot; heptachlor, heptachlorepoxid cis- (= exo, B), heptachlorepoxid trans- (= endo, A), aldrin, dieldrin, endrin, endrin aldehyd, endrin keton, isodrin, oxychlordan, cis-nonachlor, trans-nonachlor, trans-chlordane (= gama), cis-chlordane (= alfa), endosulfan I (= alfa), endosulfan II (= beta), endosulfan sulfát, chlordecon, methoxychlor, mirex, hexachlorcyklohexan HCH (alfa-HCH, beta-HCH, gama-HCH, delta-HCH, epsilon-HCH), pesticidy (p,p'-DDT, o,p'-DDT, p,p'-DDE, o,p'-DDE, p,p'-DDD, o,p'-DDD), pentachlorbenzen, hexachlorbenzen, výpočet sum HCH a pesticidů z naměřených hodnot","search_text":"Powietrze zewnętrzne i wewnętrzne Oznaczanie wskaźnikowych polichlorowanych bifenyli (PCB), pestycydów chloroorganicznych (OCP) i pestycydów cyklodienowych metodą rozcieńczenia izotopowego GC-MS/MS metoda rozcieńczenia izotopowego GC-MS/MS Vnější a vnitřní ovzduší Stanovení indikátorových polychlorovaných bifenylů (PCB), organochlorových pesticidů (OCP) a cyklodienových pesticidů, metodou isotopově zřeďovací GC-MS/MS metodou isotopově zřeďovací GC-MS/MS SOP-LSA-056 (EPA Method TO-4A) Powietrze zewnetrzne i wewnetrzne Oznaczanie wskaznikowych polichlorowanych bifenyli (PCB), pestycydow chloroorganicznych (OCP) i pestycydow cyklodienowych metoda rozcienczenia izotopowego GC-MS/MS metoda rozcienczenia izotopowego GC-MS/MS Vnejsi a vnitrni ovzdusi Stanoveni indikatorovych polychlorovanych bifenylu (PCB), organochlorovych pesticidu (OCP) a cyklodienovych pesticidu, metodou isotopove zredovaci GC-MS/MS metodou isotopove zredovaci GC-MS/MS SOP-LSA-056 (EPA Method TO-4A)","search_en":"Outdoor and indoor air Determination of indicator polychlorinated biphenyls (PCB), organochlorine pesticides (OCP), and cyclodiene pesticides by isotope dilution method GC-MS/MS isotope dilution method GC-MS/MS SOP-LSA-056 (EPA Method TO-4A)","search_zh":"室外和室内空气 同位素稀释GC-MS/MS法测定指示性多氯联苯（PCB）、有机氯农药（OCP）和环二烯类农药 同位素稀释GC-MS/MS法 SOP-LSA-056 (EPA Method TO-4A)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3dec1a309ec4ab0540951e1e","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"8","test_object":"Krew i jej składniki (surowica, osocze), mocz","test_object_en":"Whole blood and its components (serum, plasma) and urine","test_object_zh":"血液及其成分（血清、血浆）、尿液","test_object_cs":"Krev a její složky (sérum, plasma), moč","methodology":"Oznaczanie pierwiastków metodą ICP-MS","methodology_en":"Determination of trace elements by ICP-MS method","methodology_zh":"ICP-MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP-MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda ICP-MS","technique_en":"ICP-MS method","technique_zh":"ICP-MS法","technique_cs":"metodou ICP-MS","techniques":["metoda ICP-MS"],"techniques_en":["ICP-MS method"],"techniques_zh":["ICP-MS法"],"techniques_cs":["metodou ICP-MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP-MS\nmetoda ICP-MS","reference":"SOP-LSA-807","norm_bases":["SOP-LSA-807"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: As, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Zn. Literatura źródłowa: Gajek, R., Barley, F., & She, J. W. (2013). Determination of essential and toxic metals in blood by ICP-MS with calibration in synthetic matrix. Analytical Methods, 5(9), 2193-2202; Wahlen, R., Evans, L., Turner, J., & Hearn, R. (2005). The Use of Collision/Reaction Cell ICP-MS for the Simultaneous Determination of 18 Elements in Blood and Serum Samples. Agilent ICP-MS application literature.","note_en":"Determined analytes: As, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Zn. Source literature: Gajek, R., Barley, F., & She, J. W. (2013). Determination of essential and toxic metals in blood by ICP-MS with calibration in synthetic matrix. Analytical Methods, 5(9), 2193-2202; Wahlen, R., Evans, L., Turner, J., & Hearn, R. (2005). The Use of Collision/Reaction Cell ICP-MS for the Simultaneous Determination of 18 Elements in Blood and Serum Samples. Agilent ICP-MS application literature.","note_zh":"测定的分析物：As、Cd、Co、Cr、Cu、Hg、Mn、Ni、Pb、Sb、Se、Zn。参考文献：Gajek, R., Barley, F., & She, J. W. (2013). Determination of essential and toxic metals in blood by ICP-MS with calibration in synthetic matrix. Analytical Methods, 5(9), 2193-2202; Wahlen, R., Evans, L., Turner, J., & Hearn, R. (2005). The Use of Collision/Reaction Cell ICP-MS for the Simultaneous Determination of 18 Elements in Blood and Serum Samples. Agilent ICP-MS application literature.","note_cs":"Stanovované analyty: As, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Zn. Zdrojová literatura: Gajek, R., Barley, F., & She, J. W. (2013). Determination of essential and toxic metals in blood by ICP-MS with calibration in synthetic matrix. Analytical Methods, 5(9), 2193-2202; Wahlen, R., Evans, L., Turner, J., & Hearn, R. (2005). The Use of Collision/Reaction Cell ICP-MS for the Simultaneous Determination of 18 Elements in Blood and Serum Samples. Agilent ICP-MS application literature.","search_text":"Krew i jej składniki (surowica, osocze), mocz Oznaczanie pierwiastków metodą ICP-MS metoda ICP-MS Krev a její složky (sérum, plasma), moč Stanovení prvků metodou ICP-MS metodou ICP-MS SOP-LSA-807 Krew i jej skladniki (surowica, osocze), mocz Oznaczanie pierwiastkow metoda ICP-MS metoda ICP-MS Krev a jeji slozky (serum, plasma), moc Stanoveni prvku metodou ICP-MS metodou ICP-MS SOP-LSA-807","search_en":"Whole blood and its components (serum, plasma) and urine Determination of trace elements by ICP-MS method ICP-MS method SOP-LSA-807","search_zh":"血液及其成分（血清、血浆）、尿液 ICP-MS法测定元素 ICP-MS法 SOP-LSA-807","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc2f1adc1498e4a8aeccb466","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"9","test_object":"Gleby, żywność, pasze, materiał biologiczny pochodzenia zwierzęcego i roślinnego","test_object_en":"Soils, food, feed, biological material of animal and plant origin","test_object_zh":"土壤、食品、饲料、动植物源生物材料","test_object_cs":"Půdy, potraviny, krmiva, biologický materiál živočišného a rostlinného původu","methodology":"Oznaczanie suchej masy metodą grawimetryczną i zawartości wody (wilgotności) obliczeniowo z wyników pomiarów","methodology_en":"Determination of dry matter by gravimetry and water content (moisture content) by calculation from measured values","methodology_zh":"重量法测定干物质，由测量值计算含水量（水分）","methodology_cs":"Stanovení sušiny gravimetricky a obsahu vody (vlhkosti) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda grawimetryczna"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":["zawartość wody (wilgotność) obliczeniowo"],"computed_en":["water content (moisture content) by calculation from measured values"],"computed_zh":["含水量（水分）（计算）"],"computed_cs":["obsahu vody (vlhkosti) výpočtem z naměřených hodnot"],"activity":"Oznaczanie suchej masy metodą grawimetryczną i zawartości wody (wilgotności) obliczeniowo z wyników pomiarów\nmetoda grawimetryczna","reference":"SOP-LSA-057 (ČSN EN 15934, metoda A; ČSN 46 7092-3)","norm_bases":["SOP-LSA-057","ČSN EN 15934, metoda A","ČSN 46 7092-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, żywność, pasze, materiał biologiczny pochodzenia zwierzęcego i roślinnego Oznaczanie suchej masy metodą grawimetryczną i zawartości wody (wilgotności) obliczeniowo z wyników pomiarów metoda grawimetryczna zawartość wody (wilgotność) obliczeniowo Půdy, potraviny, krmiva, biologický materiál živočišného a rostlinného původu Stanovení sušiny gravimetricky a obsahu vody (vlhkosti) výpočtem z naměřených hodnot gravimetricky obsahu vody (vlhkosti) výpočtem z naměřených hodnot SOP-LSA-057 (ČSN EN 15934, metoda A; ČSN 46 7092-3) Gleby, zywnosc, pasze, material biologiczny pochodzenia zwierzecego i roslinnego Oznaczanie suchej masy metoda grawimetryczna i zawartosci wody (wilgotnosci) obliczeniowo z wynikow pomiarow metoda grawimetryczna zawartosc wody (wilgotnosc) obliczeniowo Pudy, potraviny, krmiva, biologicky material zivocisneho a rostlinneho puvodu Stanoveni susiny gravimetricky a obsahu vody (vlhkosti) vypoctem z namerenych hodnot gravimetricky obsahu vody (vlhkosti) vypoctem z namerenych hodnot SOP-LSA-057 (CSN EN 15934, metoda A; CSN 46 7092-3)","search_en":"Soils, food, feed, biological material of animal and plant origin Determination of dry matter by gravimetry and water content (moisture content) by calculation from measured values by gravimetry water content (moisture content) by calculation from measured values SOP-LSA-057 (ČSN EN 15934, metoda A; ČSN 46 7092-3)","search_zh":"土壤、食品、饲料、动植物源生物材料 重量法测定干物质，由测量值计算含水量（水分） 重量法 含水量（水分）（计算） SOP-LSA-057 (ČSN EN 15934, metoda A; ČSN 46 7092-3)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"055807bf78e91ef89d07216a","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"10","test_object":"Żywność i pasze","test_object_en":"Food and feed","test_object_zh":"食品和饲料","test_object_cs":"Potraviny a krmiva","methodology":"Oznaczanie tłuszczu metodą grawimetryczną","methodology_en":"Determination of fat by gravimetry","methodology_zh":"重量法测定脂肪","methodology_cs":"Stanovení tuku gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda grawimetryczna"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tłuszczu metodą grawimetryczną\nmetoda grawimetryczna","reference":"SOP-LSA-058 (ČSN EN ISO 2450; ČSN EN ISO 17189; ISO 11085)","norm_bases":["SOP-LSA-058","ČSN EN ISO 2450","ČSN EN ISO 17189","ISO 11085"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Żywność i pasze Oznaczanie tłuszczu metodą grawimetryczną metoda grawimetryczna Potraviny a krmiva Stanovení tuku gravimetricky gravimetricky SOP-LSA-058 (ČSN EN ISO 2450; ČSN EN ISO 17189; ISO 11085) Zywnosc i pasze Oznaczanie tluszczu metoda grawimetryczna metoda grawimetryczna Potraviny a krmiva Stanoveni tuku gravimetricky gravimetricky SOP-LSA-058 (CSN EN ISO 2450; CSN EN ISO 17189; ISO 11085)","search_en":"Food and feed Determination of fat by gravimetry by gravimetry SOP-LSA-058 (ČSN EN ISO 2450; ČSN EN ISO 17189; ISO 11085)","search_zh":"食品和饲料 重量法测定脂肪 重量法 SOP-LSA-058 (ČSN EN ISO 2450; ČSN EN ISO 17189; ISO 11085)","categories":["food","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eab9a30264281a756bb3f4c0","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"11","test_object":"Woda powierzchniowa, pitna i morska","test_object_en":"Surface, drinking and sea water","test_object_zh":"地表水、饮用水和海水","test_object_cs":"Povrchová, pitná a mořská voda","methodology":"Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metodą rozcieńczenia izotopowego LC-MS/MS","methodology_en":"Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS","methodology_zh":"同位素稀释LC-MS/MS法测定选定的极性全氟和多氟烷基物质（PFAS）","methodology_cs":"Stanovení vybraných polárních per- a polyfluorovaných látek (PFAS) metodou isotopově zřeďovací LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego LC-MS/MS","technique_en":"isotope dilution method LC-MS/MS","technique_zh":"同位素稀释LC-MS/MS法","technique_cs":"metodou isotopově zřeďovací LC-MS/MS","techniques":["metoda rozcieńczenia izotopowego LC-MS/MS"],"techniques_en":["isotope dilution method LC-MS/MS"],"techniques_zh":["同位素稀释LC-MS/MS法"],"techniques_cs":["metodou isotopově zřeďovací LC-MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metodą rozcieńczenia izotopowego LC-MS/MS\nmetoda rozcieńczenia izotopowego LC-MS/MS","reference":"SOP-LSA-510","norm_bases":["SOP-LSA-510"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: substancje per- i polifluoroalkilowe PFAS w zakresie: kwas perfluoro-n-butanowy (PFBA), kwas perfluoro-n-pentanowy (PFPeA), kwas perfluoro-n-heksanowy (PFHxA), kwas perfluoro-n-heptanowy (PFHpA), kwas perfluoro-n-oktanowy (PFOA), kwas perfluoro-n-nonanowy (PFNA), kwas perfluoro-n-dekanowy (PFDA), perfluoro-1-butanosulfonian (PFBS), perfluoro-n-heksanosulfonian (PFHxS), perfluoro-n-oktanosulfonian (PFOS). Literatura źródłowa: Susan T. Wolf and William K. Reagen, Method and validation for the analysis of perfluorinated compounds in water by pre-sampling isotope dilution-direct injection-LC/MS/MS, Anal. Methods, 2013, 5, 2444. SOP 511","note_en":"Determined analytes: Per-and polyfluoroalkyl substances PFAS in the range of: Perfluoro-n-butanoic acid (PFBA), perfluoro-n-pentanoic acid (PFPeA), perfluoro-n-hexanoic acid (PFHxA), perfluoro-n-heptanoic acid (PFHpA), perfluoro-n-octanoic acid (PFOA), perfluoro-n-nonanoic acid (PFNA), perfluoro-n-decanoic acid (PFDA), perfluoro-1-butanesulfonate (PFBS), perfluoro-n-hexanesulfonate (PFHxS), perfluoro-n-octanesulfonate (PFOS). Source literature: Susan T. Wolf and William K. Reagen, Method and validation for the analysis of perfluorinated compounds in water by pre-sampling isotope dilution-direct injection-LC/MS/MS, Anal. Methods, 2013, 5, 2444. SOP 511","note_zh":"测定的分析物：全氟和多氟烷基物质PFAS，范围：全氟正丁酸（PFBA）、全氟正戊酸（PFPeA）、全氟正己酸（PFHxA）、全氟正庚酸（PFHpA）、全氟正辛酸（PFOA）、全氟正壬酸（PFNA）、全氟正癸酸（PFDA）、全氟-1-丁烷磺酸盐（PFBS）、全氟正己烷磺酸盐（PFHxS）、全氟正辛烷磺酸盐（PFOS）。参考文献：Susan T. Wolf and William K. Reagen, Method and validation for the analysis of perfluorinated compounds in water by pre-sampling isotope dilution-direct injection-LC/MS/MS, Anal. Methods, 2013, 5, 2444. SOP 511","note_cs":"Stanovované analyty: Per- a polyfluorované alkylové sloučeniny PFAS v rozsahu: Perfluoro-n-butanová kyselina (PFBA), perfluoro-n-pentanová kyselina (PFPeA), perfluoro-n-hexanová kyselina (PFHxA), perfluoro-n-heptanová kyselina (PFHpA), perfluoro-n-oktanová kyselina (PFOA), perfluoro-n-nonanová kyselina (PFNA), perfluoro-n-dekanová kyselina (PFDA), perfluoro-1-butansulfonát (PFBS), perfluoro-n-hexansulfonát (PFHxS), perfluoro-n-oktansulfonát (PFOS). Zdrojová literatura: Susan T. Wolf and William K. Reagen, Method and validation for the analysis of perfluorinated compounds in water by pre-sampling isotope dilution-direct injection-LC/MS/MS, Anal. Methods, 2013, 5, 2444. SOP 511","search_text":"Woda powierzchniowa, pitna i morska Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metodą rozcieńczenia izotopowego LC-MS/MS metoda rozcieńczenia izotopowego LC-MS/MS Povrchová, pitná a mořská voda Stanovení vybraných polárních per- a polyfluorovaných látek (PFAS) metodou isotopově zřeďovací LC-MS/MS metodou isotopově zřeďovací LC-MS/MS SOP-LSA-510 Woda powierzchniowa, pitna i morska Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metoda rozcienczenia izotopowego LC-MS/MS metoda rozcienczenia izotopowego LC-MS/MS Povrchova, pitna a morska voda Stanoveni vybranych polarnich per- a polyfluorovanych latek (PFAS) metodou isotopove zredovaci LC-MS/MS metodou isotopove zredovaci LC-MS/MS SOP-LSA-510","search_en":"Surface, drinking and sea water Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS isotope dilution method LC-MS/MS SOP-LSA-510","search_zh":"地表水、饮用水和海水 同位素稀释LC-MS/MS法测定选定的极性全氟和多氟烷基物质（PFAS） 同位素稀释LC-MS/MS法 SOP-LSA-510","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"78085afcec77a470b5e8eae1","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"12","test_object":"Surowica krwi, osocze, mleko matki","test_object_en":"Blood serum, plasma, and breast milk","test_object_zh":"血清、血浆、母乳","test_object_cs":"Krevní sérum, plasma, mateřské mléko","methodology":"Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metodą rozcieńczenia izotopowego LC-MS/MS","methodology_en":"Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS","methodology_zh":"同位素稀释LC-MS/MS法测定选定的极性全氟和多氟烷基物质（PFAS）","methodology_cs":"Stanovení vybraných polárních per- a polyfluorovaných látek (PFAS) metodou isotopově zřeďovací LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego LC-MS/MS","technique_en":"isotope dilution method LC-MS/MS","technique_zh":"同位素稀释LC-MS/MS法","technique_cs":"metodou isotopově zřeďovací LC-MS/MS","techniques":["metoda rozcieńczenia izotopowego LC-MS/MS"],"techniques_en":["isotope dilution method LC-MS/MS"],"techniques_zh":["同位素稀释LC-MS/MS法"],"techniques_cs":["metodou isotopově zřeďovací LC-MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metodą rozcieńczenia izotopowego LC-MS/MS\nmetoda rozcieńczenia izotopowego LC-MS/MS","reference":"SOP-LSA-510","norm_bases":["SOP-LSA-510"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: substancje per- i polifluoroalkilowe PFAS w zakresie: kwas perfluoro-n-butanowy (PFBA), kwas perfluoro-n-pentanowy (PFPeA), kwas perfluoro-n-heksanowy (PFHxA), kwas perfluoro-n-heptanowy (PFHpA), kwas perfluoro-n-oktanowy (PFOA), kwas perfluoro-n-nonanowy (PFNA), kwas perfluoro-n-dekanowy (PFDA), perfluoro-1-butanosulfonian (PFBS), perfluoro-n-heksanosulfonian (PFHxS), perfluoro-n-oktanosulfonian (PFOS). Literatura źródłowa: S. Salihovic, A. Kärrman, G. Lindström, P. Monica Lind, L. Lind, B. van Bavel, A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry, J Chromatogr. A, Volume 1305, 2013, Pages 164-170. SOP 514, SOP 515","note_en":"Determined analytes: Per-and polyfluoroalkyl substances PFAS in the range of: Perfluoro-n-butanoic acid (PFBA), perfluoro-n-pentanoic acid (PFPeA), perfluoro-n-hexanoic acid (PFHxA), perfluoro-n-heptanoic acid (PFHpA), perfluoro-n-octanoic acid (PFOA), perfluoro-n-nonanoic acid (PFNA), perfluoro-n-decanoic acid (PFDA), perfluoro-1-butanesulfonate (PFBS), perfluoro-n-hexanesulfonate (PFHxS), perfluoro-n-octanesulfonate (PFOS). Source literature: S. Salihovic, A. Kärrman, G. Lindström, P. Monica Lind, L. Lind, B. van Bavel, A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry, J Chromatogr. A, Volume 1305, 2013, Pages 164-170. SOP 514, SOP 515","note_zh":"测定的分析物：全氟和多氟烷基物质PFAS，范围：全氟正丁酸（PFBA）、全氟正戊酸（PFPeA）、全氟正己酸（PFHxA）、全氟正庚酸（PFHpA）、全氟正辛酸（PFOA）、全氟正壬酸（PFNA）、全氟正癸酸（PFDA）、全氟-1-丁烷磺酸盐（PFBS）、全氟正己烷磺酸盐（PFHxS）、全氟正辛烷磺酸盐（PFOS）。参考文献：S. Salihovic, A. Kärrman, G. Lindström, P. Monica Lind, L. Lind, B. van Bavel, A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry, J Chromatogr. A, Volume 1305, 2013, Pages 164-170. SOP 514, SOP 515","note_cs":"Stanovované analyty: Per- a polyfluorované alkylové sloučeniny PFAS v rozsahu: Perfluoro-n-butanová kyselina (PFBA), perfluoro-n-pentanová kyselina (PFPeA), perfluoro-n-hexanová kyselina (PFHxA), perfluoro-n-heptanová kyselina (PFHpA), perfluoro-n-oktanová kyselina (PFOA), perfluoro-n-nonanová kyselina (PFNA), perfluoro-n-dekanová kyselina (PFDA), perfluoro-1-butansulfonát (PFBS), perfluoro-n-hexansulfonát (PFHxS), perfluoro-n-oktansulfonát (PFOS). Zdrojová literatura: S. Salihovic, A. Kärrman, G. Lindström, P. Monica Lind, L. Lind, B. van Bavel, A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry, J Chromatogr. A, Volume 1305, 2013, Pages 164-170. SOP 514, SOP 515","search_text":"Surowica krwi, osocze, mleko matki Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metodą rozcieńczenia izotopowego LC-MS/MS metoda rozcieńczenia izotopowego LC-MS/MS Krevní sérum, plasma, mateřské mléko Stanovení vybraných polárních per- a polyfluorovaných látek (PFAS) metodou isotopově zřeďovací LC-MS/MS metodou isotopově zřeďovací LC-MS/MS SOP-LSA-510 Surowica krwi, osocze, mleko matki Oznaczanie wybranych polarnych substancji per- i polifluoroalkilowych (PFAS) metoda rozcienczenia izotopowego LC-MS/MS metoda rozcienczenia izotopowego LC-MS/MS Krevni serum, plasma, materske mleko Stanoveni vybranych polarnich per- a polyfluorovanych latek (PFAS) metodou isotopove zredovaci LC-MS/MS metodou isotopove zredovaci LC-MS/MS SOP-LSA-510","search_en":"Blood serum, plasma, and breast milk Determination of selected polar per- and polyfluorinated substances (PFASs) by isotope dilution method LC-MS/MS isotope dilution method LC-MS/MS SOP-LSA-510","search_zh":"血清、血浆、母乳 同位素稀释LC-MS/MS法测定选定的极性全氟和多氟烷基物质（PFAS） 同位素稀释LC-MS/MS法 SOP-LSA-510","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d0992722831102594c61145c","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"13","test_object":"Krew i jej składniki (surowica, osocze), mocz i mleko matki, włosy, gleby, osady denne, popiół lotny, mech, igliwie","test_object_en":"Whole blood and its components (serum, plasma), urine, breast milk, hair, soils, sediments, fly ash, moss, and needles","test_object_zh":"血液及其成分（血清、血浆）、尿液和母乳、头发、土壤、沉积物、飞灰、苔藓、针叶","test_object_cs":"Krev a její složky (sérum, plasma), moč a mateřské mléko, vlasy, půdy, sedimenty, popílek, mech, jehličí","methodology":"Oznaczanie rtęci metodą AAS analizatorem AMA 254","methodology_en":"Determination of mercury by AAS method using the AMA 254 analyzer","methodology_zh":"使用AMA 254分析仪AAS法测定汞","methodology_cs":"Stanovení rtuti metodou AAS analyzátorem AMA 254","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda AAS, analizator AMA 254","technique_en":"AAS method using the AMA 254 analyzer","technique_zh":"AAS法（AMA 254分析仪）","technique_cs":"metodou AAS analyzátorem AMA 254","techniques":["metoda AAS, analizator AMA 254"],"techniques_en":["AAS method using the AMA 254 analyzer"],"techniques_zh":["AAS法（AMA 254分析仪）"],"techniques_cs":["metodou AAS analyzátorem AMA 254"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci metodą AAS analizatorem AMA 254\nmetoda AAS, analizator AMA 254","reference":"SOP-LSA-808","norm_bases":["SOP-LSA-808"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Literatura źródłowa: Instrukcja obsługi, Altec s.r.o., Praga, 2002. Díez, S., Montuori, P., Querol, X., Bayona, J.M. Total mercury in the hair of children by combustion atomic absorption spectrometry (Comb-AAS), (2007) Journal of Analytical Toxicology, 31 (3), pp. 144-149. Száková, J., Kolihová, D., Miholová, D., Mader, P. Single-purpose atomic absorption spectrometer AMA-254 for mercury determination and its performance in analysis of agricultural and environmental materials (2004) Chemical Papers, 58 (5), pp. 311-315. Spevácková, V., Korunová, V., Cejchanová, M., Vobecký, M. Sampling procedure and a radio-indicator study of mercury determination in whole blood by using an AMA 254 atomic absorption spectrometer (2004) Analytical and bioanalytical chemistry, 380 (2), pp. 346-350.","note_en":"Source literature: Operating Instructions, Altec s.r.o., Prague, 2002. Díez, S., Montuori, P., Querol, X., Bayona, J.M. Total mercury in the hair of children by combustion atomic absorption spectrometry (Comb-AAS), (2007) Journal of Analytical Toxicology, 31 (3), pp. 144-149. Száková, J., Kolihová, D., Miholová, D., Mader, P. Single-purpose atomic absorption spectrometer AMA-254 for mercury determination and its performance in analysis of agricultural and environmental materials (2004) Chemical Papers, 58 (5), pp. 311-315. Spevácková, V., Korunová, V., Cejchanová, M., Vobecký, M. Sampling procedure and a radio-indicator study of mercury determination in whole blood by using an AMA 254 atomic absorption spectrometer (2004) Analytical and bioanalytical chemistry, 380 (2), pp. 346-350.","note_zh":"参考文献：操作说明书，Altec s.r.o.，布拉格，2002。Díez, S., Montuori, P., Querol, X., Bayona, J.M. Total mercury in the hair of children by combustion atomic absorption spectrometry (Comb-AAS), (2007) Journal of Analytical Toxicology, 31 (3), pp. 144-149. Száková, J., Kolihová, D., Miholová, D., Mader, P. Single-purpose atomic absorption spectrometer AMA-254 for mercury determination and its performance in analysis of agricultural and environmental materials (2004) Chemical Papers, 58 (5), pp. 311-315. Spevácková, V., Korunová, V., Cejchanová, M., Vobecký, M. Sampling procedure and a radio-indicator study of mercury determination in whole blood by using an AMA 254 atomic absorption spectrometer (2004) Analytical and bioanalytical chemistry, 380 (2), pp. 346-350.","note_cs":"Zdrojová literatura: Návod k obsluze, Altec s.r.o., Praha, 2002. Díez, S., Montuori, P., Querol, X., Bayona, J.M. Total mercury in the hair of children by combustion atomic absorption spectrometry (Comb-AAS), (2007) Journal of Analytical Toxicology, 31 (3), pp. 144-149. Száková, J., Kolihová, D., Miholová, D., Mader, P. Single-purpose atomic absorption spectrometer AMA-254 for mercury determination and its performance in analysis of agricultural and environmental materials (2004) Chemical Papers, 58 (5), pp. 311-315. Spevácková, V., Korunová, V., Cejchanová, M., Vobecký, M. Sampling procedure and a radio-indicator study of mercury determination in whole blood by using an AMA 254 atomic absorption spectrometer (2004) Analytical and bioanalytical chemistry, 380 (2), pp. 346-350.","search_text":"Krew i jej składniki (surowica, osocze), mocz i mleko matki, włosy, gleby, osady denne, popiół lotny, mech, igliwie Oznaczanie rtęci metodą AAS analizatorem AMA 254 metoda AAS, analizator AMA 254 Krev a její složky (sérum, plasma), moč a mateřské mléko, vlasy, půdy, sedimenty, popílek, mech, jehličí Stanovení rtuti metodou AAS analyzátorem AMA 254 metodou AAS analyzátorem AMA 254 SOP-LSA-808 Krew i jej skladniki (surowica, osocze), mocz i mleko matki, wlosy, gleby, osady denne, popiol lotny, mech, igliwie Oznaczanie rteci metoda AAS analizatorem AMA 254 metoda AAS, analizator AMA 254 Krev a jeji slozky (serum, plasma), moc a materske mleko, vlasy, pudy, sedimenty, popilek, mech, jehlici Stanoveni rtuti metodou AAS analyzatorem AMA 254 metodou AAS analyzatorem AMA 254 SOP-LSA-808","search_en":"Whole blood and its components (serum, plasma), urine, breast milk, hair, soils, sediments, fly ash, moss, and needles Determination of mercury by AAS method using the AMA 254 analyzer AAS method using the AMA 254 analyzer SOP-LSA-808","search_zh":"血液及其成分（血清、血浆）、尿液和母乳、头发、土壤、沉积物、飞灰、苔藓、针叶 使用AMA 254分析仪AAS法测定汞 AAS法（AMA 254分析仪） SOP-LSA-808","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b1a1c6ee9c392b696316a9c4","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"14","test_object":"Powietrze zewnętrzne i wewnętrzne","test_object_en":"Outdoor and indoor air","test_object_zh":"室外和室内空气","test_object_cs":"Vnější a vnitřní ovzduší","methodology":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego GC-MS/MS","methodology_en":"Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS","methodology_zh":"同位素稀释GC-MS/MS法测定选定的持久性有机污染物（POP）","methodology_cs":"Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací GC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego GC-MS/MS","technique_en":"isotope dilution method GC-MS/MS","technique_zh":"同位素稀释GC-MS/MS法","technique_cs":"metodou isotopové zřeďovací GC-MS/MS","techniques":["metoda rozcieńczenia izotopowego GC-MS/MS"],"techniques_en":["isotope dilution method GC-MS/MS"],"techniques_zh":["同位素稀释GC-MS/MS法"],"techniques_cs":["metodou isotopové zřeďovací GC-MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego GC-MS/MS\nmetoda rozcieńczenia izotopowego GC-MS/MS","reference":"SOP-LSA-031 mimo kap. 3, bod b až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","norm_bases":["SOP-LSA-031 mimo kap. 3, bod b až o","EPA Method 1613B","EPA Method 1668B","EPA Method 1614"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: polichlorowane dibenzo-p-dioksyny PCDD i polichlorowane dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, obliczanie parametrów TEQ PCDD/F z wyników pomiarów); dioksynopodobne polichlorowane bifenyle PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, obliczanie sum PCB i parametrów TEQ z wyników pomiarów); wskaźnikowe polichlorowane bifenyle PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, obliczanie sum PCB z wyników pomiarów); polibromowane difenyloetery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209). Literatura źródłowa: van Bavel B, Geng D, Cherta L, Nácher-Mestre J, Portolés T, Ábalos M, Sauló J, Abad E, Dunstan J, Jones R, Kotz A, Winterhalter H, Malisch R, Traag W, Hagberg J, Ericson Jogsten I, Beltran J, Hernández F. Atmospheric-pressure chemical ionization tandem mass spectrometry (APGC/MS/MS) an alternative to high-resolution mass spectrometry (HRGC/HRMS) for the determination of dioxins. Anal Chem. 2015 Sep 1;87(17):9047-53.","note_en":"Determined analytes: Polychlorinated dibenzo-p-dioxins PCDD and polychlorinated dibenzo-p-furans PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, calculation of TEQ PCDD/F parameters from measured values); dioxin-like polychlorinated biphenyls PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, calculation of PCB sum and TEQ parameters from measured values); indicator polychlorinated biphenyls PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, calculation of PCB sums from measured values); polybrominated diphenyl ethers PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209). Source literature: van Bavel B, Geng D, Cherta L, Nácher-Mestre J, Portolés T, Ábalos M, Sauló J, Abad E, Dunstan J, Jones R, Kotz A, Winterhalter H, Malisch R, Traag W, Hagberg J, Ericson Jogsten I, Beltran J, Hernández F. Atmospheric-pressure chemical ionization tandem mass spectrometry (APGC/MS/MS) an alternative to high-resolution mass spectrometry (HRGC/HRMS) for the determination of dioxins. Anal Chem. 2015 Sep 1;87(17):9047-53.","note_zh":"测定的分析物：多氯二苯并对二噁英PCDD和多氯二苯并呋喃PCDF（2378-TCDD、12378-PeCDD、123678-HxCDD、123478-HxCDD、234678-HxCDD、1234678-HpCDD、OCDD、2378-TCDF、12378-PeCDF、23478-PeCDF、123678-HxCDF、123478-HxCDF、234678-HxCDF、123789-HxCDF、1234678-HpCDF、1234789-HpCDF、OCDF，由测量值计算TEQ PCDD/F参数）；二噁英类多氯联苯PCB（PCB 77、PCB 81、PCB 105、PCB 114、PCB 118、PCB 123、PCB 126、PCB 156、PCB 157、PCB 167、PCB 169、PCB 189，由测量值计算PCB总量和TEQ参数）；指示性多氯联苯PCB（PCB 28、PCB 52、PCB 101、PCB 118、PCB 138、PCB 153、PCB 180，由测量值计算PCB总量）；多溴二苯醚PBDE（BDE 28、BDE 47、BDE 99、BDE 100、BDE 153、BDE 154、BDE 183、BDE 209）。参考文献：van Bavel B, Geng D, Cherta L, Nácher-Mestre J, Portolés T, Ábalos M, Sauló J, Abad E, Dunstan J, Jones R, Kotz A, Winterhalter H, Malisch R, Traag W, Hagberg J, Ericson Jogsten I, Beltran J, Hernández F. Atmospheric-pressure chemical ionization tandem mass spectrometry (APGC/MS/MS) an alternative to high-resolution mass spectrometry (HRGC/HRMS) for the determination of dioxins. Anal Chem. 2015 Sep 1;87(17):9047-53.","note_cs":"Stanovované analyty: Polychlorované dibenzo-p-dioxiny PCDD a polychlorované dibenzo-p-furany PCDF (2378-TCDD, 12378-PeCDD, 123678-HxCDD, 123478-HxCDD, 234678-HxCDD, 1234678-HpCDD, OCDD, 2378-TCDF, 12378-PeCDF, 23478-PeCDF, 123678-HxCDF, 123478-HxCDF, 234678-HxCDF, 123789-HxCDF, 1234678-HpCDF, 1234789-HpCDF, OCDF, výpočet parametrů TEQ PCDD/F z naměřených hodnot); dioxinům podobné polychlorované bifenyly PCB (PCB 77, PCB 81, PCB 105, PCB 114, PCB 118, PCB 123, PCB 126, PCB 156, PCB 157, PCB 167, PCB 169, PCB 189, výpočet sum PCB a parametrů TEQ z naměřených hodnot); indikátorové polychlorované bifenyly PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, výpočet sum PCB z naměřených hodnot); polybromované difenylétery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209). Zdrojová literatura: van Bavel B, Geng D, Cherta L, Nácher-Mestre J, Portolés T, Ábalos M, Sauló J, Abad E, Dunstan J, Jones R, Kotz A, Winterhalter H, Malisch R, Traag W, Hagberg J, Ericson Jogsten I, Beltran J, Hernández F. Atmospheric-pressure chemical ionization tandem mass spectrometry (APGC/MS/MS) an alternative to high-resolution mass spectrometry (HRGC/HRMS) for the determination of dioxins. Anal Chem. 2015 Sep 1;87(17):9047-53.","search_text":"Powietrze zewnętrzne i wewnętrzne Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego GC-MS/MS metoda rozcieńczenia izotopowego GC-MS/MS Vnější a vnitřní ovzduší Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací GC-MS/MS metodou isotopové zřeďovací GC-MS/MS SOP-LSA-031 mimo kap. 3, bod b až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614) Powietrze zewnetrzne i wewnetrzne Oznaczanie wybranych trwalych zanieczyszczen organicznych (TZO/POP) metoda rozcienczenia izotopowego GC-MS/MS metoda rozcienczenia izotopowego GC-MS/MS Vnejsi a vnitrni ovzdusi Stanoveni vybranych perzistentnich organickych polutantu (POP) metodou isotopove zredovaci GC-MS/MS metodou isotopove zredovaci GC-MS/MS SOP-LSA-031 mimo kap. 3, bod b az o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","search_en":"Outdoor and indoor air Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS isotope dilution method GC-MS/MS SOP-LSA-031 mimo kap. 3, bod b až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","search_zh":"室外和室内空气 同位素稀释GC-MS/MS法测定选定的持久性有机污染物（POP） 同位素稀释GC-MS/MS法 SOP-LSA-031 mimo kap. 3, bod b až o (EPA Method 1613B; EPA Method 1668B; EPA Method 1614)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"64f187f780e7ab8a0c983843","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"15","test_object":"Surowica krwi, osocze","test_object_en":"Blood serum, plasma","test_object_zh":"血清、血浆","test_object_cs":"Krevní sérum, plasma","methodology":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego GC-MS/MS","methodology_en":"Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS","methodology_zh":"同位素稀释GC-MS/MS法测定选定的持久性有机污染物（POP）","methodology_cs":"Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací GC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego GC-MS/MS","technique_en":"isotope dilution method GC-MS/MS","technique_zh":"同位素稀释GC-MS/MS法","technique_cs":"metodou isotopové zřeďovací GC-MS/MS","techniques":["metoda rozcieńczenia izotopowego GC-MS/MS"],"techniques_en":["isotope dilution method GC-MS/MS"],"techniques_zh":["同位素稀释GC-MS/MS法"],"techniques_cs":["metodou isotopové zřeďovací GC-MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego GC-MS/MS\nmetoda rozcieńczenia izotopowego GC-MS/MS","reference":"SOP-LSA-066","norm_bases":["SOP-LSA-066"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: wskaźnikowe polichlorowane bifenyle PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, obliczanie sum PCB z wyników pomiarów); polibromowane difenyloetery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209), uniepalniacze nowego typu (aDP, sDP), pestycydy (p,p'-DDT, o,p'-DDT, p,p'-DDE, o,p'-DDE, p,p'-DDD, o,p'-DDD). Literatura źródłowa: Samira Salihovic, Lisa Mattioli, Gunilla Lindström, Lars Lind, P. Monica Lind, Bert van Bavel, A rapid method for screening of the Stockholm Convention POPs in small amounts of human plasma using SPE and HRGC/HRMS, Chemosphere, Volume 86, Issue 7, 2012, Pages 747-753. Samira Salihovic, Helena Nilsson, Jessika Hagberg, Gunilla Lindström, Trends in the analysis of persistent organic pollutants (POPs) in human blood, TrAC Trends in Analytical Chemistry, Volume 46, 2013, Pages 129-138. Jordan Stubleski, Petr Kukucka, Samira Salihovic, P. Monica Lind, Lars Lind, Anna Kärrman, A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction, Journal of Chromatography A, Volume 1546, 2018, Pages 18-27.","note_en":"Determined analytes: Indicator polychlorinated biphenyls PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, calculation of the sums of PCB from measured values); polybrominated diphenyl ethers PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209), new type retardants (aDP, sDP), pesticides (p,p'-DDT, o,p'-DDT, p,p'-DDE, o,p'-DDE, p,p'-DDD, o,p'-DDD). Source literature: Samira Salihovic, Lisa Mattioli, Gunilla Lindström, Lars Lind, P. Monica Lind, Bert van Bavel, A rapid method for screening of the Stockholm Convention POPs in small amounts of human plasma using SPE and HRGC/HRMS, Chemosphere, Volume 86, Issue 7, 2012, Pages 747-753. Samira Salihovic, Helena Nilsson, Jessika Hagberg, Gunilla Lindström, Trends in the analysis of persistent organic pollutants (POPs) in human blood, TrAC Trends in Analytical Chemistry, Volume 46, 2013, Pages 129-138. Jordan Stubleski, Petr Kukucka, Samira Salihovic, P. Monica Lind, Lars Lind, Anna Kärrman, A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction, Journal of Chromatography A, Volume 1546, 2018, Pages 18-27.","note_zh":"测定的分析物：指示性多氯联苯PCB（PCB 28、PCB 52、PCB 101、PCB 118、PCB 138、PCB 153、PCB 180，由测量值计算PCB总量）；多溴二苯醚PBDE（BDE 28、BDE 47、BDE 99、BDE 100、BDE 153、BDE 154、BDE 183、BDE 209）、新型阻燃剂（aDP、sDP）、农药（p,p'-DDT、o,p'-DDT、p,p'-DDE、o,p'-DDE、p,p'-DDD、o,p'-DDD）。参考文献：Samira Salihovic, Lisa Mattioli, Gunilla Lindström, Lars Lind, P. Monica Lind, Bert van Bavel, A rapid method for screening of the Stockholm Convention POPs in small amounts of human plasma using SPE and HRGC/HRMS, Chemosphere, Volume 86, Issue 7, 2012, Pages 747-753. Samira Salihovic, Helena Nilsson, Jessika Hagberg, Gunilla Lindström, Trends in the analysis of persistent organic pollutants (POPs) in human blood, TrAC Trends in Analytical Chemistry, Volume 46, 2013, Pages 129-138. Jordan Stubleski, Petr Kukucka, Samira Salihovic, P. Monica Lind, Lars Lind, Anna Kärrman, A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction, Journal of Chromatography A, Volume 1546, 2018, Pages 18-27.","note_cs":"Stanovované analyty: Indikátorové polychlorované bifenyly PCB (PCB 28, PCB 52, PCB 101, PCB 118, PCB 138, PCB 153, PCB 180, výpočet sum PCB z naměřených hodnot); polybromované difenylétery PBDE (BDE 28, BDE 47, BDE 99, BDE 100, BDE 153, BDE 154, BDE 183, BDE 209), zpomalovače nového typu (aDP, sDP), pesticidy (p,p'-DDT, o,p'-DDT, p,p'-DDE, o,p'-DDE, p,p'-DDD, o,p'-DDD). Zdrojová literatura: Samira Salihovic, Lisa Mattioli, Gunilla Lindström, Lars Lind, P. Monica Lind, Bert van Bavel, A rapid method for screening of the Stockholm Convention POPs in small amounts of human plasma using SPE and HRGC/HRMS, Chemosphere, Volume 86, Issue 7, 2012, Pages 747-753. Samira Salihovic, Helena Nilsson, Jessika Hagberg, Gunilla Lindström, Trends in the analysis of persistent organic pollutants (POPs) in human blood, TrAC Trends in Analytical Chemistry, Volume 46, 2013, Pages 129-138. Jordan Stubleski, Petr Kukucka, Samira Salihovic, P. Monica Lind, Lars Lind, Anna Kärrman, A method for analysis of marker persistent organic pollutants in low-volume plasma and serum samples using 96-well plate solid phase extraction, Journal of Chromatography A, Volume 1546, 2018, Pages 18-27.","search_text":"Surowica krwi, osocze Oznaczanie wybranych trwałych zanieczyszczeń organicznych (TZO/POP) metodą rozcieńczenia izotopowego GC-MS/MS metoda rozcieńczenia izotopowego GC-MS/MS Krevní sérum, plasma Stanovení vybraných perzistentních organických polutantů (POP) metodou isotopové zřeďovací GC-MS/MS metodou isotopové zřeďovací GC-MS/MS SOP-LSA-066 Surowica krwi, osocze Oznaczanie wybranych trwalych zanieczyszczen organicznych (TZO/POP) metoda rozcienczenia izotopowego GC-MS/MS metoda rozcienczenia izotopowego GC-MS/MS Krevni serum, plasma Stanoveni vybranych perzistentnich organickych polutantu (POP) metodou isotopove zredovaci GC-MS/MS metodou isotopove zredovaci GC-MS/MS SOP-LSA-066","search_en":"Blood serum, plasma Determination of selected persistent organic pollutants (POP) by isotope dilution method GC-MS/MS isotope dilution method GC-MS/MS SOP-LSA-066","search_zh":"血清、血浆 同位素稀释GC-MS/MS法测定选定的持久性有机污染物（POP） 同位素稀释GC-MS/MS法 SOP-LSA-066","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8644bea03564e5afe539c0bb","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"16","test_object":"Mocz","test_object_en":"Urine","test_object_zh":"尿液","test_object_cs":"Moč","methodology":"Oznaczanie metabolitów ftalanów, ich zamienników i bisfenoli metodą rozcieńczenia izotopowego LC-MS/MS","methodology_en":"Determination of metabolites of phthalates, phthalate alternatives and bisphenols by isotopic dilution method LC-MS/MS","methodology_zh":"同位素稀释LC-MS/MS法测定邻苯二甲酸酯及其替代物代谢物和双酚类","methodology_cs":"Stanovení metabolitů ftalátů, jejich alternativ a bisfenolů metodou isotopově zřeďovací LC-MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda rozcieńczenia izotopowego LC-MS/MS","technique_en":"isotope dilution method LC-MS/MS","technique_zh":"同位素稀释LC-MS/MS法","technique_cs":"metodou isotopově zřeďovací LC-MS/MS","techniques":["metoda rozcieńczenia izotopowego LC-MS/MS"],"techniques_en":["isotope dilution method LC-MS/MS"],"techniques_zh":["同位素稀释LC-MS/MS法"],"techniques_cs":["metodou isotopově zřeďovací LC-MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metabolitów ftalanów, ich zamienników i bisfenoli metodą rozcieńczenia izotopowego LC-MS/MS\nmetoda rozcieńczenia izotopowego LC-MS/MS","reference":"SOP-LSA-515","norm_bases":["SOP-LSA-515"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Oznaczane anality: bisfenole w zakresie: bisfenol A, bisfenol S, bisfenol F; metabolity ftalanów w zakresie: ftalan mono(2-etylo-5-oksoheksylu) (5-OH-MEHP), ftalan mono(2-etylo-5-oksoheksylu) (5-oxo-MEHP), ftalan mono(2-etylo-5-karboksypentylu) (5-cx-MEPP), ftalan mono(2-etyloheksylu) (MEHP), ftalan mono-n-butylu (MnBP), ftalan monoizobutylu (MiBP), ftalan monobenzylu (MBzP), ftalan monoetylu (MEP), ftalan monohydroksyizononylu (OH-MiNP), ftalan mono-(7-karboksy-4-metyloheptylu) (cx-MiNP), ftalan mono-n-oktylu (MnOP), ftalan monocykloheksylu (MCHP), ftalan 6-hydroksymonopropyloheptylu (OH-MiDP); metabolity zamienników ftalanów w zakresie: ester mono-(7-hydroksy-4-metylo)oktylowy kwasu cykloheksano-1,2-dikarboksylowego (OH-MINCH), ester mono-4-metylo-7-karboksyheptylowy kwasu 1,2-cykloheksanodikarboksylowego (cx-MINCH), ester mono-(7-okso-4-metylo)oktylowy kwasu cykloheksano-1,2-dikarboksylowego (oxo-MINCH), tereftalan mono(2-etylo-5-hydroksyheksylu) (5OH-MEHTP), tereftalan mono-2-etylo-5-karboksypentylu (5cx-MEPTP). Literatura źródłowa: The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6306.04, Metabolites of phthalates and phthalate alternatives/Urine/HPLC/ESI-MS/MS, April, 2013 The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6301.02, Benzophenone-3, bisphenol A, 2,4-dichlorophenol, 2,5-dichlorophenol, methyl-, ethyl-, propyl-, and butyl parabens, triclosan / Urine/ On line SPE-HPLC-Isotope dilution-MS/MS, April 16, 2013","note_en":"Determined analytes: Bisphenols: Bisphenol A, Bisphenol S, Bisphenol F; Metabolites of phthalates: Mono(2-ethyl-5-oxohexyl) phthalate (5-OH-MEHP), Mono(2-ethyl-5-oxohexyl) phthalate (5-oxo-MEHP), Mono-(2-ethyl-5-carboxypentyl) phthalate (5-cx-MEPP), Mono(2-ethylhexyl) phthalate (MEHP), Mono-n-butyl phthalate (MnBP), Monoisobutyl phthalate (MiBP), Monobenzyl phthalate (MBzP), Monoethyl phthalate (MEP), Monohydroxyisononyl phthalate (OH-MiNP), Mono-(7-carboxy-4-methylheptyl) phthalate (cx-MiNP), Mono-n-octyl phthalate (MnOP), Monocyclohexyl phthalate (MCHP), 6-Hydroxy monopropylheptyl phthalate (OH-MiDP); Phthalate alternatives: Cyclohexane-1,2-dicarboxylate-mono-(7-hydroxy-4-methyl)octyl ester (OH-MINCH), 1,2-Cyclohexanedicarboxylic acid mono 4-methyl-7-carboxy-heptyl ester (cx-MINCH), Cyclohexane-1,2-dicarboxylate-mono-(7-oxo-4-methyl)octyl ester (oxo-MINCH), Mono(2-ethyl-5-hydroxyhexyl) terephthalate (5OH-MEHTP), Mono-2-ethyl-5-carboxypentyl terephthalate (5cx-MEPTP). Source literature: The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6306.04, Metabolites of phthalates and phthalate alternatives/Urine/HPLC/ESI-MS/MS, April, 2013 The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6301.02, Benzophenone-3, bisphenol A, 2,4-dichlorophenol, 2,5-dichlorophenol, methyl-, ethyl-, propyl-, and butyl parabens, triclosan / Urine/ On line SPE-HPLC-Isotope dilution-MS/MS, April 16, 2013","note_zh":"测定的分析物：双酚类，范围：双酚A、双酚S、双酚F；邻苯二甲酸酯代谢物，范围：邻苯二甲酸单(2-乙基-5-氧代己基)酯（5-OH-MEHP）、邻苯二甲酸单(2-乙基-5-氧代己基)酯（5-oxo-MEHP）、邻苯二甲酸单(2-乙基-5-羧基戊基)酯（5-cx-MEPP）、邻苯二甲酸单(2-乙基己基)酯（MEHP）、邻苯二甲酸单正丁酯（MnBP）、邻苯二甲酸单异丁酯（MiBP）、邻苯二甲酸单苄酯（MBzP）、邻苯二甲酸单乙酯（MEP）、邻苯二甲酸单羟基异壬酯（OH-MiNP）、邻苯二甲酸单(7-羧基-4-甲基庚基)酯（cx-MiNP）、邻苯二甲酸单正辛酯（MnOP）、邻苯二甲酸单环己酯（MCHP）、邻苯二甲酸6-羟基单丙基庚酯（OH-MiDP）；邻苯二甲酸酯替代物代谢物，范围：环己烷-1,2-二甲酸单(7-羟基-4-甲基)辛酯（OH-MINCH）、1,2-环己烷二甲酸单4-甲基-7-羧基庚酯（cx-MINCH）、环己烷-1,2-二甲酸单(7-氧代-4-甲基)辛酯（oxo-MINCH）、对苯二甲酸单(2-乙基-5-羟基己基)酯（5OH-MEHTP）、对苯二甲酸单2-乙基-5-羧基戊酯（5cx-MEPTP）。参考文献：The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6306.04, Metabolites of phthalates and phthalate alternatives/Urine/HPLC/ESI-MS/MS, April, 2013 The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6301.02, Benzophenone-3, bisphenol A, 2,4-dichlorophenol, 2,5-dichlorophenol, methyl-, ethyl-, propyl-, and butyl parabens, triclosan / Urine/ On line SPE-HPLC-Isotope dilution-MS/MS, April 16, 2013","note_cs":"Stanovované analyty: Bisfenoly v rozsahu: bisfenol A, bisfenol S, bisfenol F; Metabolity ftalátů v rozsahu: mono(2-ethyl-5-oxohexyl) ftalát (5-OH-MEHP), mono(2-ethyl-5-oxohexyl) ftalát (5-oxo-MEHP), mono(2-ethyl-5-karboxypentyl) ftalát (5-cx-MEPP), mono(2-ethylhexyl) ftalát (MEHP), mono-n-butyl ftalát (MnBP), monoisobutyl ftalát (MiBP), monobenzyl ftalát (MBzP), monoethyl ftalát (MEP), monohydroxyisononyl ftalát (OH-MiNP), mono-(7-carboxy-4-methylheptyl) ftalát (cx-MiNP), mono-n-oktyl ftalát (MnOP), monocyklohexyl ftalát (MCHP), 6-hydroxy monopropylheptyl ftalát (OH-MiDP); Metabolity alternativ ftalátů v rozsahu: cyclohexane-1,2- dicarboxylate-mono-(7- hydroxy-4-methyl)octyl ester (OH-MINCH), 1,2-Cyclohexanedicarboxylic Acid Mono 4-Methyl-7-carboxy-heptyl ester (cx-MINCH), cyclohexane-1,2- dicarboxylate-mono-(7-oxo- 4-methyl)octyl ester (oxo-MINCH), Mono(2-ethyl-5-hydroxyhexyl) tereftalát (5OH-MEHTP), Mono-2-ethyl-5-carboxypentyl tereftalát (5cx-MEPTP). Zdrojová literatura: The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6306.04, Metabolites of phthalates and phthalate alternatives/Urine/HPLC/ESI-MS/MS, April, 2013 The Centers for Disease Control and Prevention (CDC), Laboratory Procedure Manual, Method No. 6301.02, Benzophenone-3, bisphenol A, 2,4-dichlorophenol, 2,5-dichlorophenol, methyl-, ethyl-, propyl-, and butyl parabens, triclosan / Urine/ On line SPE-HPLC-Isotope dilution-MS/MS, April 16, 2013","search_text":"Mocz Oznaczanie metabolitów ftalanów, ich zamienników i bisfenoli metodą rozcieńczenia izotopowego LC-MS/MS metoda rozcieńczenia izotopowego LC-MS/MS Moč Stanovení metabolitů ftalátů, jejich alternativ a bisfenolů metodou isotopově zřeďovací LC-MS/MS metodou isotopově zřeďovací LC-MS/MS SOP-LSA-515 Mocz Oznaczanie metabolitow ftalanow, ich zamiennikow i bisfenoli metoda rozcienczenia izotopowego LC-MS/MS metoda rozcienczenia izotopowego LC-MS/MS Moc Stanoveni metabolitu ftalatu, jejich alternativ a bisfenolu metodou isotopove zredovaci LC-MS/MS metodou isotopove zredovaci LC-MS/MS SOP-LSA-515","search_en":"Urine Determination of metabolites of phthalates, phthalate alternatives and bisphenols by isotopic dilution method LC-MS/MS isotope dilution method LC-MS/MS SOP-LSA-515","search_zh":"尿液 同位素稀释LC-MS/MS法测定邻苯二甲酸酯及其替代物代谢物和双酚类 同位素稀释LC-MS/MS法 SOP-LSA-515","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9a092611a8028f636e077c5f","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"1","test_object":"Powietrze zewnętrzne i wewnętrzne","test_object_en":"Outdoor and indoor air","test_object_zh":"室外和室内空气","test_object_cs":"Vnější a vnitřní ovzduší","methodology":"Pobieranie próbek powietrza do oznaczania trwałych zanieczyszczeń organicznych (POP) i metali z poborem na sorbent stały (pianka poliuretanowa, filtr, pianka poliuretanowa + filtr)","methodology_en":"Air sampling for the determination of persistent organic pollutants (POPs) and metals using solid sorbent (polyurethane foam, filter, polyurethane foam + filter)","methodology_zh":"用固体吸附剂（聚氨酯泡沫、滤膜、聚氨酯泡沫+滤膜）采集空气样品以测定持久性有机污染物（POP）和金属","methodology_cs":"Odběry vzorků ovzduší pro stanovení perzistentních organických látek (POP) a kovů po odběru na pevný sorbent (polyuretanová pěna, filtr, polyuretanová pěna + filtr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza do oznaczania trwałych zanieczyszczeń organicznych (POP) i metali z poborem na sorbent stały (pianka poliuretanowa, filtr, pianka poliuretanowa + filtr)","reference":"SOP-LSA-921 (ČSN EN ISO 16000-1; ČSN EN ISO 16000-12; ČSN EN 12341; ČSN EN 14902; ČSN EN 15549; ISO 12884)","norm_bases":["SOP-LSA-921","ČSN EN ISO 16000-1","ČSN EN ISO 16000-12","ČSN EN 12341","ČSN EN 14902","ČSN EN 15549","ISO 12884"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze zewnętrzne i wewnętrzne Pobieranie próbek powietrza do oznaczania trwałych zanieczyszczeń organicznych (POP) i metali z poborem na sorbent stały (pianka poliuretanowa, filtr, pianka poliuretanowa + filtr) Vnější a vnitřní ovzduší Odběry vzorků ovzduší pro stanovení perzistentních organických látek (POP) a kovů po odběru na pevný sorbent (polyuretanová pěna, filtr, polyuretanová pěna + filtr) SOP-LSA-921 (ČSN EN ISO 16000-1; ČSN EN ISO 16000-12; ČSN EN 12341; ČSN EN 14902; ČSN EN 15549; ISO 12884) Powietrze zewnetrzne i wewnetrzne Pobieranie probek powietrza do oznaczania trwalych zanieczyszczen organicznych (POP) i metali z poborem na sorbent staly (pianka poliuretanowa, filtr, pianka poliuretanowa + filtr) Vnejsi a vnitrni ovzdusi Odbery vzorku ovzdusi pro stanoveni perzistentnich organickych latek (POP) a kovu po odberu na pevny sorbent (polyuretanova pena, filtr, polyuretanova pena + filtr) SOP-LSA-921 (CSN EN ISO 16000-1; CSN EN ISO 16000-12; CSN EN 12341; CSN EN 14902; CSN EN 15549; ISO 12884)","search_en":"Outdoor and indoor air Air sampling for the determination of persistent organic pollutants (POPs) and metals using solid sorbent (polyurethane foam, filter, polyurethane foam + filter) SOP-LSA-921 (ČSN EN ISO 16000-1; ČSN EN ISO 16000-12; ČSN EN 12341; ČSN EN 14902; ČSN EN 15549; ISO 12884)","search_zh":"室外和室内空气 用固体吸附剂（聚氨酯泡沫、滤膜、聚氨酯泡沫+滤膜）采集空气样品以测定持久性有机污染物（POP）和金属 SOP-LSA-921 (ČSN EN ISO 16000-1; ČSN EN ISO 16000-12; ČSN EN 12341; ČSN EN 14902; ČSN EN 15549; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"659562495d79e8c0fefe7889","lab_id":"69ad52a4de79e566650fd514","country":"CZ","accr_number":"1666","accr_body":"ČIA","row_label":"4","test_object":"Gleba","test_object_en":"Soil","test_object_zh":"土壤","test_object_cs":"Půda","methodology":"Pobieranie próbek gleb do oznaczania trwałych zanieczyszczeń organicznych (POP) i metali","methodology_en":"Soil sampling for the determination of persistent organic pollutants (POPs) and metals","methodology_zh":"采集土壤样品以测定持久性有机污染物（POP）和金属","methodology_cs":"Odběry vzorků půd pro stanovení perzistentních organických látek (POP) a kovů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gleb do oznaczania trwałych zanieczyszczeń organicznych (POP) i metali","reference":"SOP-LSA-985 (ISO 18400; ČSN EN ISO 16133)","norm_bases":["SOP-LSA-985","ISO 18400","ČSN EN ISO 16133"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleba Pobieranie próbek gleb do oznaczania trwałych zanieczyszczeń organicznych (POP) i metali Půda Odběry vzorků půd pro stanovení perzistentních organických látek (POP) a kovů SOP-LSA-985 (ISO 18400; ČSN EN ISO 16133) Gleba Pobieranie probek gleb do oznaczania trwalych zanieczyszczen organicznych (POP) i metali Puda Odbery vzorku pud pro stanoveni perzistentnich organickych latek (POP) a kovu SOP-LSA-985 (ISO 18400; CSN EN ISO 16133)","search_en":"Soil Soil sampling for the determination of persistent organic pollutants (POPs) and metals SOP-LSA-985 (ISO 18400; ČSN EN ISO 16133)","search_zh":"土壤 采集土壤样品以测定持久性有机污染物（POP）和金属 SOP-LSA-985 (ISO 18400; ČSN EN ISO 16133)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}