🇨🇿 E&H services a.s. PL

ČIA 1665 • Dobrá, Czech Republic • 12 methods

EnvironmentWater & wastewaterFood & beveragesPharma & cosmetics

E&H services a.s. is a laboratory accredited by ČIA under number 1665 (Dobrá, Czech Republic). Its accreditation scope covers 12 test methods in the following areas: Environment, Water & wastewater, Food & beverages, Pharma & cosmetics. Test objects include: Air, emission, Cosmetics, Drinking, surface, underground and waste water, Drinking, underground and surface water, dialyzates from SPMD.

At a glance

  • Accreditation number: ČIA 1665
  • Methods in scope: 12
  • Types of test objects: 12
  • City: Dobrá, Czech Republic
  • Valid until: 14-03-2027
Accreditation number
1665
Accreditation body
ČIA
Address
Dobrá 240, 739 51 Dobrá
City
Dobrá, Czech Republic
Division
Laboratorium Badawcze
Valid until
14-03-2027

What this laboratory tests (12)

Certificate information

Certificate date
18.12.2024

Accreditation scope — test methods (12)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, underground and surface water, dialyzates from SPMD Determination of polyaromatic hydrocarbons (PAH) by gas chromatography (MS) and the sum of PAH by calculation from measured values
naphthalene acenaphthene acenaphthylene phenanthrene anthracene fluorene fluoranthene pyrene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene chrysene dibenz(a,h)anthracene indeno(1,2,3-cd)pyrene
sum of PAH (calculated)
Regulated area: Tests
SOP 6.00 (ČSN 75 7554)
2 Emission, air Determination of polyaromatic hydrocarbons (PAH) by gas chromatography (MS) and the sum of PAH by calculation from measured values
naphthalene acenaphthene acenaphthylene phenanthrene anthracene fluorene fluoranthene pyrene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(ghi)perylene benzo(k)fluoranthene chrysene dibenz(a,h)anthracene indeno(1,2,3-cd)pyrene
sum of PAH (calculated)
Regulated area: Tests
SOP 6.04 (ČSN 75 7554; EPA TO 13; STN ISO 11338-2)
3 Water, extracts, dialyzates from SPMD Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values
Dibenzo-p-dioxines and -furanes (PCDD/F) Polychlorinated biphenyls (PCB) polybrominated diphenylethers (PBDE)
sum of PCDD/F, PCB and PBDE (calculated)
Regulated area: Tests
SOP 7.00 (EPA 1613)
4 Solid samples Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values
Dibenzo-p-dioxines and -furanes (PCDD/F) Polychlorinated biphenyls (PCB) polybrominated diphenylethers (PBDE)
sum of PCDD/F, PCB and PBDE (calculated)
Regulated area: Tests
SOP 7.01 (EPA 1613)
5 Air, emission Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values
Dibenzo-p-dioxines and -furanes (PCDD/F) Polychlorinated biphenyls (PCB) polybrominated diphenylethers (PBDE)
sum of PCDD/F, PCB and PBDE (calculated)
Regulated area: Tests
SOP 7.04 (ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4+A1)
6 Water, dialyzates from SPMD Determination of hydrocarbons C10 to C40 by gas chromatography (FID)
Regulated area: Tests
SOP 10.00 (ČSN EN ISO 9377-2)
7 Solid samples, feedstuffs, biological materials Determination of dry matter by gravimetry and water content (moisture content) by calculation from measured values
Regulated area: Tests
SOP 13.00 (ČSN EN 14346, část A)
8 Vegetable materials Determination of cannabinoids by liquid chromatography (MS)
CBD (cannabidiol) CBDA (cannabidiolic acid) THC (tetrahydrocannabinol) THCA (tetrahydrocannabinolic acid) CBG (cannabigerol) CBGA (cannabigerolic acid) CBN (cannabinol)
Regulated area: Tests
SOP 16.02
9 Food and food supplements Determination of cannabinoids by liquid chromatography (MS)
CBD (cannabidiol) CBDA (cannabidiolic acid) THC (tetrahydrocannabinol) THCA (tetrahydrocannabinolic acid) CBG (cannabigerol) CBGA (cannabigerolic acid) CBN (cannabinol)
Regulated area: Tests
SOP 16.03
10 Cosmetics Determination of cannabinoids by liquid chromatography (MS)
CBD (cannabidiol) CBDA (cannabidiolic acid) THC (tetrahydrocannabinol) THCA (tetrahydrocannabinolic acid) CBG (cannabigerol) CBGA (cannabigerolic acid) CBN (cannabinol)
Regulated area: Tests
SOP 16.05
11 Drinking, surface, underground and waste water Sampling with semipermeable membrane devices (SPMD), passive sampler POCIS and DGT
Regulated area: Sampling
SOP 1.00 VZ (ČSN EN ISO 5667-23)
12 Soils, sands, sludge, waste Manual sampling of waste and solid samples
Regulated area: Sampling
SOP 2.00 VZ (ČSN EN ISO 5667–1; ČSN EN ISO 5667–3; ČSN EN ISO 5667–13; ČSN ISO 5667–14; ČSN ISO 5667–15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN 015110; ČSN 015111; ČSN 015112; ČSN EN 14899; ČSN EN ISO 19458; ČSN EN ISO 3170; Metodický pokyn MŽP ke vzorkování odpadů 2008, 101s)

Reference standards (39)

EPA 1613
EPA TO 13
Metodický pokyn MŽP ke vzorkování odpadů 2008, 101s
SOP 1.00 VZ
SOP 10.00
SOP 13.00
SOP 16.02
SOP 16.03
SOP 16.05
SOP 2.00 VZ
SOP 6.00
SOP 6.04
SOP 7.00
SOP 7.01
SOP 7.04
STN ISO 11338-2
TNI CEN/TR 15310-1
TNI CEN/TR 15310-2
TNI CEN/TR 15310-3
TNI CEN/TR 15310-4
TNI CEN/TR 15310-5
ČSN 015110
ČSN 015111
ČSN 015112
ČSN 75 7554
ČSN EN 14346, část A
ČSN EN 14899
ČSN EN 1948-2
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN ISO 19458
ČSN EN ISO 3170
ČSN EN ISO 5667-23
ČSN EN ISO 5667–1
ČSN EN ISO 5667–13
ČSN EN ISO 5667–3
ČSN EN ISO 9377-2
ČSN ISO 5667–14
ČSN ISO 5667–15

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1665