{"lab":{"_id":"69ad52a4de79e566650fd512","accr_number":"1665","country":"CZ","accr_body":"ČIA","address":"Dobrá 240, 739 51 Dobrá","categories":["environment","water","food","pharma"],"city":"Dobrá","imported_at":"2026-03-08T10:42:44.590Z","methods_count":12,"name":"E&H services a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1665_690_2024_CS.pdf","1665_690_2024_EN.pdf"],"scope_summary":"Specjalistyczne analizy organiczne wód, wyciągów, próbek stałych, materiału biologicznego, pasz, powietrza, żywności i suplementów diety, preparatów kosmetycznych, analizy substancji organicznych z próbników pasywnych, pobieranie próbek wód próbnikami pasywnymi (SPMD, POCIS, DGT) i pobieranie próbek materiałów stałych.","search_text":"e&h services a.s. dobrá 240, 739 51 dobrá 1665","status":"active","updated_at":"2026-03-08T14:52:14.452Z","valid_from":"","valid_until":"14-03-2027","website":"www.ehss.eu","email_confidence":"high","email_mx":true,"email_source":"https://www.ehss.eu","map_coord":[49.685584,18.40478],"map_geo":"nominatim-street","certificate_date":"18.12.2024","certificate_no":"690/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Specjalistyczne analizy organiczne wód, wyciągów, próbek stałych, materiału biologicznego, pasz, powietrza, żywności i suplementów diety, preparatów kosmetycznych, analizy substancji organicznych z próbników pasywnych, pobieranie próbek wód próbnikami pasywnymi (SPMD, POCIS, DGT) i pobieranie próbek materiałów stałych.","en":"Special organic analysis of water, extracts, solid samples, biological material, feed, air, food and food supplements, cosmetics; analysis of organic compounds from passive samplers; sampling of water by passive samplers (SPMD, POCIS, DGT) and sampling of solid materials.","zh":"水、浸出液、固体样品、生物材料、饲料、空气、食品及其补充剂、化妆品的专项有机分析，被动采样器中有机物的分析，用被动采样器（SPMD、POCIS、DGT）采集水样以及固体材料的采样。","cs":"Speciální organické analýzy vod, výluhů, pevných vzorků, biologického materiálu, krmiv, ovzduší, potravin a jejich doplňků, kosmetických přípravků, analýzy organických látek z pasivních vzorkovačů, odběr vzorků vod pasivními vzorkovači (SPMD, POCIS, DGT) a odběr pevných materiálů."}],"flexible_scope":true,"flexible_scope_url":"https://cannabilab.eu/seznam-cinnosti-v-ramci-flexibilniho-rozsahu-akreditace/","has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"FID","pl":"Detektor płomieniowo-jonizacyjny","en":"Flame ionization detector","zh":"火焰离子化检测器","cs":"Plamenově-ionizační detektor"},{"abbr":"HRMS","pl":"Spektrometria mas o wysokiej rozdzielczości","en":"High-resolution mass spectrometry","zh":"高分辨质谱","cs":"Hmotnostní spektrometrie s vysokým rozlišením"},{"abbr":"ISO","pl":"Międzynarodowa Organizacja Normalizacyjna (International Organization for Standardisation)","en":"International Organization for Standardisation","zh":"国际标准化组织（International Organization for Standardisation）","cs":"International Organization for Standardisation"},{"abbr":"MS","pl":"Spektrometria mas","en":"Mass spectrometry","zh":"质谱","cs":"Hmotová spektrometrie"},{"abbr":"MS/MS","pl":"Tandemowy detektor mas","en":"Tandem mass detector","zh":"串联质谱检测器","cs":"Tandemový hmotnostní detektor"},{"abbr":"POCIS","pl":"Polar Organic Chemical Integrative Sampler (pasywny próbnik związków polarnych)","en":"Polar Organic Chemical Integrative Sampler","zh":"Polar Organic Chemical Integrative Sampler（极性有机化合物整合采样器）","cs":"Polar Organic Chemical Integrative Sampler"},{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard operating procedure","zh":"标准操作程序","cs":"Standardní operační postup"},{"abbr":"SPMD","pl":"Semipermeable Membrane Device (urządzenie z membraną półprzepuszczalną)","en":"Semipermeable Membrane Device","zh":"Semipermeable Membrane Device（半透膜装置）","cs":"Semipermeable Membrane Device"},{"abbr":"STN","pl":"Słowacka norma techniczna","en":"Slovak technical standard","zh":"斯洛伐克技术标准","cs":"Slovenská technická norma"},{"abbr":"TEQ","pl":"Równoważnik toksyczności","en":"Toxic equivalent","zh":"毒性当量","cs":"Toxický ekvivalent"},{"abbr":"US EPA","pl":"U.S. Environmental Protection Agency (Agencja Ochrony Środowiska USA)","en":"U.S. Environmental Protection Agency","zh":"U.S. Environmental Protection Agency（美国环境保护署）","cs":"U.S. Environmental Protection Agency"}],"scope_notes":[{"pl":"Laboratorium przedstawia opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供意见和检测结果解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."},{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立进行采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"b095bac5547cda0705570a6385d87a8ae3f6023547b1f69db94ad0fd4646a651","source_pdf_url":"https://www.cai.cz/OA/pdf/P690_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P690_2024_EN.pdf"},"methods":[{"_id":"2baf9635e942b70327a37fcd","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"5","test_object":"Wody pitne, podziemne i powierzchniowe, dializaty z SPMD","test_object_en":"Drinking, underground and surface water, dialyzates from SPMD","test_object_zh":"饮用水、地下水和地表水，SPMD透析液","test_object_cs":"Vody pitné, podzemní a povrchové, dialyzáty z SPMD","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartości zmierzonych","methodology_en":"Determination of polyaromatic hydrocarbons (PAH) by gas chromatography (MS) and the sum of PAH by calculation from measured values","methodology_zh":"气相色谱法（MS）测定多环芳烃（PAU），并由测量值计算多环芳烃总和","methodology_cs":"Stanovení polyaromatických uhlovodíků (PAU) plynovou chromatografií (MS) a sumy PAU výpočtem z naměřených hodnot","parameters":[{"name":"naftalen","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoren","range":""},{"name":"fluoranten","range":""},{"name":"piren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"benzo(a)piren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"chryzen","range":""},{"name":"dibenzo(a,h)antracen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""}],"parameters_en":[{"name":"naphthalene","range":""},{"name":"acenaphthene","range":""},{"name":"acenaphthylene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"fluorene","range":""},{"name":"fluoranthene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(ghi)perylene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"chrysene","range":""},{"name":"dibenz(a,h)anthracene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"苊","range":""},{"name":"苊烯","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"芴","range":""},{"name":"荧蒽","range":""},{"name":"芘","range":""},{"name":"苯并(a)蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(ghi)苝","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"䓛","range":""},{"name":"二苯并(a,h)蒽","range":""},{"name":"茚并(1,2,3-cd)芘","range":""}],"parameters_cs":[{"name":"Naftalen","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoren","range":""},{"name":"fluoranten","range":""},{"name":"pyren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"benzo(a)pyren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"chrysen","range":""},{"name":"dibenz(a,h,)antracen","range":""},{"name":"indeno(123-cd)pyren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma WWA"],"computed_en":["sum of PAH"],"computed_zh":["多环芳烃总和"],"computed_cs":["suma PAU"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartości zmierzonych\nZakres:\nnaftalen\nacenaften\nacenaftylen\nfenantren\nantracen\nfluoren\nfluoranten\npiren\nbenzo(a)antracen\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(ghi)perylen\nbenzo(k)fluoranten\nchryzen\ndibenzo(a,h)antracen\nindeno(1,2,3-cd)piren","reference":"SOP 6.00 (ČSN 75 7554)","norm_bases":["SOP 6.00","ČSN 75 7554"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne, podziemne i powierzchniowe, dializaty z SPMD Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartości zmierzonych naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  piren  benzo(a)antracen  benzo(a)piren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chryzen  dibenzo(a,h)antracen  indeno(1,2,3-cd)piren  suma WWA Vody pitné, podzemní a povrchové, dialyzáty z SPMD Stanovení polyaromatických uhlovodíků (PAU) plynovou chromatografií (MS) a sumy PAU výpočtem z naměřených hodnot Naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  pyren  benzo(a)antracen  benzo(a)pyren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chrysen  dibenz(a,h,)antracen  indeno(123-cd)pyren  suma PAU SOP 6.00 (ČSN 75 7554) Wody pitne, podziemne i powierzchniowe, dializaty z SPMD Oznaczanie wielopierscieniowych weglowodorow aromatycznych (WWA) metoda chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartosci zmierzonych naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  piren  benzo(a)antracen  benzo(a)piren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chryzen  dibenzo(a,h)antracen  indeno(1,2,3-cd)piren  suma WWA Vody pitne, podzemni a povrchove, dialyzaty z SPMD Stanoveni polyaromatickych uhlovodiku (PAU) plynovou chromatografii (MS) a sumy PAU vypoctem z namerenych hodnot Naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  pyren  benzo(a)antracen  benzo(a)pyren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chrysen  dibenz(a,h,)antracen  indeno(123-cd)pyren  suma PAU SOP 6.00 (CSN 75 7554)","search_en":"Drinking, underground and surface water, dialyzates from SPMD Determination of polyaromatic hydrocarbons (PAH) by gas chromatography (MS) and the sum of PAH by calculation from measured values naphthalene  acenaphthene  acenaphthylene  phenanthrene  anthracene  fluorene  fluoranthene  pyrene  benzo(a)anthracene  benzo(a)pyrene  benzo(b)fluoranthene  benzo(ghi)perylene  benzo(k)fluoranthene  chrysene  dibenz(a,h)anthracene  indeno(1,2,3-cd)pyrene  sum of PAH SOP 6.00 (ČSN 75 7554)","search_zh":"饮用水、地下水和地表水，SPMD透析液 气相色谱法（MS）测定多环芳烃（PAU），并由测量值计算多环芳烃总和 萘  苊  苊烯  菲  蒽  芴  荧蒽  芘  苯并(a)蒽  苯并(a)芘  苯并(b)荧蒽  苯并(ghi)苝  苯并(k)荧蒽  䓛  二苯并(a,h)蒽  茚并(1,2,3-cd)芘  多环芳烃总和 SOP 6.00 (ČSN 75 7554)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22c411dea1ecec1045f69370","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"6","test_object":"Emisje, powietrze","test_object_en":"Emission, air","test_object_zh":"排放物、空气","test_object_cs":"Emise, ovzduší","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartości zmierzonych","methodology_en":"Determination of polyaromatic hydrocarbons (PAH) by gas chromatography (MS) and the sum of PAH by calculation from measured values","methodology_zh":"气相色谱法（MS）测定多环芳烃（PAU），并由测量值计算多环芳烃总和","methodology_cs":"Stanovení polyaromatických uhlovodíků (PAU) plynovou chromatografií (MS) a sumy PAU výpočtem z naměřených hodnot","parameters":[{"name":"naftalen","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoren","range":""},{"name":"fluoranten","range":""},{"name":"piren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"benzo(a)piren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"chryzen","range":""},{"name":"dibenzo(a,h)antracen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""}],"parameters_en":[{"name":"naphthalene","range":""},{"name":"acenaphthene","range":""},{"name":"acenaphthylene","range":""},{"name":"phenanthrene","range":""},{"name":"anthracene","range":""},{"name":"fluorene","range":""},{"name":"fluoranthene","range":""},{"name":"pyrene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(ghi)perylene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"chrysene","range":""},{"name":"dibenz(a,h)anthracene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""}],"parameters_zh":[{"name":"萘","range":""},{"name":"苊","range":""},{"name":"苊烯","range":""},{"name":"菲","range":""},{"name":"蒽","range":""},{"name":"芴","range":""},{"name":"荧蒽","range":""},{"name":"芘","range":""},{"name":"苯并(a)蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(ghi)苝","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"䓛","range":""},{"name":"二苯并(a,h)蒽","range":""},{"name":"茚并(1,2,3-cd)芘","range":""}],"parameters_cs":[{"name":"Naftalen","range":""},{"name":"acenaften","range":""},{"name":"acenaftylen","range":""},{"name":"fenantren","range":""},{"name":"antracen","range":""},{"name":"fluoren","range":""},{"name":"fluoranten","range":""},{"name":"pyren","range":""},{"name":"benzo(a)antracen","range":""},{"name":"benzo(a)pyren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(ghi)perylen","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"chrysen","range":""},{"name":"dibenz(a,h,)antracen","range":""},{"name":"indeno(123-cd)pyren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma WWA"],"computed_en":["sum of PAH"],"computed_zh":["多环芳烃总和"],"computed_cs":["suma PAU"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartości zmierzonych\nZakres:\nnaftalen\nacenaften\nacenaftylen\nfenantren\nantracen\nfluoren\nfluoranten\npiren\nbenzo(a)antracen\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(ghi)perylen\nbenzo(k)fluoranten\nchryzen\ndibenzo(a,h)antracen\nindeno(1,2,3-cd)piren","reference":"SOP 6.04 (ČSN 75 7554; EPA TO 13; STN ISO 11338-2)","norm_bases":["SOP 6.04","ČSN 75 7554","EPA TO 13","STN ISO 11338-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Przedmiot badań: powietrze zewnętrzne, powietrze wewnętrzne, powietrze na stanowiskach pracy, emisje","note_en":"Tested subject: outdoor air, indoor air, working air, emissions","note_zh":"检测对象：室外空气、室内空气、工作场所空气、排放物","note_cs":"Předmět zkoušení: Vnější ovzduší, vnitřní ovzduší, pracovní ovzduší, emise","search_text":"Emisje, powietrze Oznaczanie wielopierścieniowych węglowodorów aromatycznych (WWA) metodą chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartości zmierzonych naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  piren  benzo(a)antracen  benzo(a)piren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chryzen  dibenzo(a,h)antracen  indeno(1,2,3-cd)piren  suma WWA Emise, ovzduší Stanovení polyaromatických uhlovodíků (PAU) plynovou chromatografií (MS) a sumy PAU výpočtem z naměřených hodnot Naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  pyren  benzo(a)antracen  benzo(a)pyren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chrysen  dibenz(a,h,)antracen  indeno(123-cd)pyren  suma PAU SOP 6.04 (ČSN 75 7554; EPA TO 13; STN ISO 11338-2) Emisje, powietrze Oznaczanie wielopierscieniowych weglowodorow aromatycznych (WWA) metoda chromatografii gazowej (MS) i sumy WWA obliczeniowo z wartosci zmierzonych naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  piren  benzo(a)antracen  benzo(a)piren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chryzen  dibenzo(a,h)antracen  indeno(1,2,3-cd)piren  suma WWA Emise, ovzdusi Stanoveni polyaromatickych uhlovodiku (PAU) plynovou chromatografii (MS) a sumy PAU vypoctem z namerenych hodnot Naftalen  acenaften  acenaftylen  fenantren  antracen  fluoren  fluoranten  pyren  benzo(a)antracen  benzo(a)pyren  benzo(b)fluoranten  benzo(ghi)perylen  benzo(k)fluoranten  chrysen  dibenz(a,h,)antracen  indeno(123-cd)pyren  suma PAU SOP 6.04 (CSN 75 7554; EPA TO 13; STN ISO 11338-2)","search_en":"Emission, air Determination of polyaromatic hydrocarbons (PAH) by gas chromatography (MS) and the sum of PAH by calculation from measured values naphthalene  acenaphthene  acenaphthylene  phenanthrene  anthracene  fluorene  fluoranthene  pyrene  benzo(a)anthracene  benzo(a)pyrene  benzo(b)fluoranthene  benzo(ghi)perylene  benzo(k)fluoranthene  chrysene  dibenz(a,h)anthracene  indeno(1,2,3-cd)pyrene  sum of PAH SOP 6.04 (ČSN 75 7554; EPA TO 13; STN ISO 11338-2)","search_zh":"排放物、空气 气相色谱法（MS）测定多环芳烃（PAU），并由测量值计算多环芳烃总和 萘  苊  苊烯  菲  蒽  芴  荧蒽  芘  苯并(a)蒽  苯并(a)芘  苯并(b)荧蒽  苯并(ghi)苝  苯并(k)荧蒽  䓛  二苯并(a,h)蒽  茚并(1,2,3-cd)芘  多环芳烃总和 SOP 6.04 (ČSN 75 7554; EPA TO 13; STN ISO 11338-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c31e36b2620ef0fb9e3dbf2","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"7","test_object":"Wody, wyciągi, dializaty z SPMD","test_object_en":"Water, extracts, dialyzates from SPMD","test_object_zh":"水、浸出液、SPMD透析液","test_object_cs":"Vody, výluhy, dialyzáty z SPMD","methodology":"Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych","methodology_en":"Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values","methodology_zh":"气相色谱法（MS/MS、HRMS）测定多氯二苯并对二噁英和呋喃（PCDD/F）、选定的多氯联苯（PCB）同类物和选定的多溴二苯醚（PBDE）同类物，并由测量值计算PCDD/F、PCB和PBDE总和","methodology_cs":"Stanovení polychlorovaných dibenzo–p-dioxinů a furanů (PCDD/F), vybraných kongenerů polychlorovaných bifenylů (PCB) a vybraných kongenerů polybromovaných difenyleterů (PBDE) plynovou chromatografií (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE výpočtem z naměřených hodnot","parameters":[{"name":"Dibenzo-p-dioksyny i furany (PCDD/F)","range":""},{"name":"Polichlorowane bifenyle (PCB)","range":""},{"name":"Polibromowane difenyloetery (PBDE)","range":""}],"parameters_en":[{"name":"Dibenzo-p-dioxines and -furanes (PCDD/F)","range":""},{"name":"Polychlorinated biphenyls (PCB)","range":""},{"name":"polybrominated diphenylethers (PBDE)","range":""}],"parameters_zh":[{"name":"二苯并对二噁英和呋喃（PCDD/F）","range":""},{"name":"多氯联苯（PCB）","range":""},{"name":"多溴二苯醚（PBDE）","range":""}],"parameters_cs":[{"name":"Dibenzo-p-dioxiny a furany (PCDD/F)","range":""},{"name":"Polychlorované bifenyly (PCB)","range":""},{"name":"Polybromované difenyletery (PBDE)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCDD/F, PCB i PBDE"],"computed_en":["sum of PCDD/F, PCB and PBDE"],"computed_zh":["PCDD/F、PCB和PBDE总和"],"computed_cs":["suma PCDD/F, PCB a PBDE"],"activity":"Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych\nZakres:\nDibenzo-p-dioksyny i furany (PCDD/F)\nPolichlorowane bifenyle (PCB)\nPolibromowane difenyloetery (PBDE)","reference":"SOP 7.00 (EPA 1613)","norm_bases":["SOP 7.00","EPA 1613"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality: dibenzo-p-dioksyny i furany (PCDD/F) – 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, suma TCDD, suma PeCCD, suma HxCDD, suma HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, suma TCDF, suma PCDF, suma HxCDF, suma HpCDF; polichlorowane bifenyle (PCB) – trichlorowane, tetrachlorowane, pentachlorowane, heksachlorowane, heptachlorowane, oktachlorowane, nonachlorowane i dekachlorowane kongenery PCB; polibromowane difenyloetery (PBDE) – PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Przedmiot badań: wody pitne, wody ciepłe, wody butelkowane, wody powierzchniowe, wody podziemne, wody w kąpieliskach, ścieki, wyciągi wodne z odpadów, dializaty z SPMD","note_en":"Determined analytes: dibenzo-p-dioxines and -furanes (PCDD/F) – 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, sum of TCDD, sum of PeCCD, sum of HxCDD, sum of HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, sum of TCDF, sum of PCDF, sum of HxCDF, sum of HpCDF; polychlorinated biphenyls (PCB) – trichlorinated, tetrachlorinated, pentachlorinated, hexachlorinated, heptachlorinated, octachlorinated, nonachlorinated and decachlorinated PCB congeners; polybrominated diphenylethers (PBDE) – PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Tested subject: drinking water, hot water, bottled water, surface water, underground water, bathing water and waste water, aqueous extracts of waste, dialyzates from SPMD","note_zh":"测定的分析物：二苯并对二噁英和呋喃（PCDD/F）——2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD、TCDD总和、PeCCD总和、HxCDD总和、HpCDD总和、2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF、TCDF总和、PCDF总和、HxCDF总和、HpCDF总和；多氯联苯（PCB）——三氯、四氯、五氯、六氯、七氯、八氯、九氯和十氯PCB同类物；多溴二苯醚（PBDE）——PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209。检测对象：饮用水、热水、瓶装水、地表水、地下水、浴场水、废水、废物水浸出液、SPMD透析液","note_cs":"Stanovované analyty: Dibenzo-p-dioxiny a furany (PCDD/F) - 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, suma TCDD, suma PeCCD, suma HxCDD, suma HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, suma TCDF, suma PCDF, suma HxCDF, suma HpCDF; Polychlorované bifenyly (PCB) - trichlorované, tetrachlorované, pentachlorované, hexachlorované, heptachlorované, oktachlorované, nonachlorované a dekachlorované kongenery PCB; Polybromované difenyletery (PBDE) - PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Předmět zkoušení: Vody pitné, vody teplé, vody balené, vody povrchové, vody podzemní, vody ke koupání, vody odpadní, vodné výluhy odpadů, dialyzáty z SPMD","search_text":"Wody, wyciągi, dializaty z SPMD Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych Dibenzo-p-dioksyny i furany (PCDD/F)  Polichlorowane bifenyle (PCB)  Polibromowane difenyloetery (PBDE)  suma PCDD/F, PCB i PBDE Vody, výluhy, dialyzáty z SPMD Stanovení polychlorovaných dibenzo–p-dioxinů a furanů (PCDD/F), vybraných kongenerů polychlorovaných bifenylů (PCB) a vybraných kongenerů polybromovaných difenyleterů (PBDE) plynovou chromatografií (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE výpočtem z naměřených hodnot Dibenzo-p-dioxiny a furany (PCDD/F)  Polychlorované bifenyly (PCB)  Polybromované difenyletery (PBDE)  suma PCDD/F, PCB a PBDE SOP 7.00 (EPA 1613) Wody, wyciagi, dializaty z SPMD Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanow (PCDD/F), wybranych kongenerow polichlorowanych bifenyli (PCB) i wybranych kongenerow polibromowanych difenyloeterow (PBDE) metoda chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartosci zmierzonych Dibenzo-p-dioksyny i furany (PCDD/F)  Polichlorowane bifenyle (PCB)  Polibromowane difenyloetery (PBDE)  suma PCDD/F, PCB i PBDE Vody, vyluhy, dialyzaty z SPMD Stanoveni polychlorovanych dibenzo–p-dioxinu a furanu (PCDD/F), vybranych kongeneru polychlorovanych bifenylu (PCB) a vybranych kongeneru polybromovanych difenyleteru (PBDE) plynovou chromatografii (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE vypoctem z namerenych hodnot Dibenzo-p-dioxiny a furany (PCDD/F)  Polychlorovane bifenyly (PCB)  Polybromovane difenyletery (PBDE)  suma PCDD/F, PCB a PBDE SOP 7.00 (EPA 1613)","search_en":"Water, extracts, dialyzates from SPMD Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values Dibenzo-p-dioxines and -furanes (PCDD/F)  Polychlorinated biphenyls (PCB)  polybrominated diphenylethers (PBDE)  sum of PCDD/F, PCB and PBDE SOP 7.00 (EPA 1613)","search_zh":"水、浸出液、SPMD透析液 气相色谱法（MS/MS、HRMS）测定多氯二苯并对二噁英和呋喃（PCDD/F）、选定的多氯联苯（PCB）同类物和选定的多溴二苯醚（PBDE）同类物，并由测量值计算PCDD/F、PCB和PBDE总和 二苯并对二噁英和呋喃（PCDD/F）  多氯联苯（PCB）  多溴二苯醚（PBDE）  PCDD/F、PCB和PBDE总和 SOP 7.00 (EPA 1613)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ab5428039e9ff10b596d832d","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"8","test_object":"Próbki stałe","test_object_en":"Solid samples","test_object_zh":"固体样品","test_object_cs":"Pevné vzorky","methodology":"Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych","methodology_en":"Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values","methodology_zh":"气相色谱法（MS/MS、HRMS）测定多氯二苯并对二噁英和呋喃（PCDD/F）、选定的多氯联苯（PCB）同类物和选定的多溴二苯醚（PBDE）同类物，并由测量值计算PCDD/F、PCB和PBDE总和","methodology_cs":"Stanovení polychlorovaných dibenzo –p-dioxinů a furanů (PCDD/F), vybraných kongenerů polychlorovaných bifenylů (PCB a vybraných kongenerů polybromovaných difenyleterů (PBDE) plynovou chromatografií (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE výpočtem z naměřených hodnot","parameters":[{"name":"Dibenzo-p-dioksyny i furany (PCDD/F)","range":""},{"name":"Polichlorowane bifenyle (PCB)","range":""},{"name":"Polibromowane difenyloetery (PBDE)","range":""}],"parameters_en":[{"name":"Dibenzo-p-dioxines and -furanes (PCDD/F)","range":""},{"name":"Polychlorinated biphenyls (PCB)","range":""},{"name":"polybrominated diphenylethers (PBDE)","range":""}],"parameters_zh":[{"name":"二苯并对二噁英和呋喃（PCDD/F）","range":""},{"name":"多氯联苯（PCB）","range":""},{"name":"多溴二苯醚（PBDE）","range":""}],"parameters_cs":[{"name":"Dibenzo-p-dioxiny a furany (PCDD/F)","range":""},{"name":"Polychlorované bifenyly (PCB)","range":""},{"name":"Polybromované difenyletery (PBDE)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCDD/F, PCB i PBDE"],"computed_en":["sum of PCDD/F, PCB and PBDE"],"computed_zh":["PCDD/F、PCB和PBDE总和"],"computed_cs":["suma PCDD/F, PCB a PBDE"],"activity":"Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych\nZakres:\nDibenzo-p-dioksyny i furany (PCDD/F)\nPolichlorowane bifenyle (PCB)\nPolibromowane difenyloetery (PBDE)","reference":"SOP 7.01 (EPA 1613)","norm_bases":["SOP 7.01","EPA 1613"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality: dibenzo-p-dioksyny i furany (PCDD/F) – 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, suma TCDD, suma PeCCD, suma HxCDD, suma HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, suma TCDF, suma PCDF, suma HxCDF, suma HpCDF; polichlorowane bifenyle (PCB) – trichlorowane, tetrachlorowane, pentachlorowane, heksachlorowane, heptachlorowane, oktachlorowane, nonachlorowane i dekachlorowane kongenery PCB; polibromowane difenyloetery (PBDE) – PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Przedmiot badań: gleby, piaski, osady denne, odpady, szlamy","note_en":"Determined analytes: dibenzo-p-dioxines and -furanes (PCDD/F) – 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, sum of TCDD, sum of PeCCD, sum of HxCDD, sum of HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, sum of TCDF, sum of PCDF, sum of HxCDF, sum of HpCDF; polychlorinated biphenyls (PCB) – trichlorinated, tetrachlorinated, pentachlorinated, hexachlorinated, heptachlorinated, octachlorinated, nonachlorinated and decachlorinated PCB congeners; polybrominated diphenylethers (PBDE) – PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Tested subject: soils, sands, sediments, waste, sludge","note_zh":"测定的分析物：二苯并对二噁英和呋喃（PCDD/F）——2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD、TCDD总和、PeCCD总和、HxCDD总和、HpCDD总和、2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF、TCDF总和、PCDF总和、HxCDF总和、HpCDF总和；多氯联苯（PCB）——三氯、四氯、五氯、六氯、七氯、八氯、九氯和十氯PCB同类物；多溴二苯醚（PBDE）——PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209。检测对象：土壤、沙、沉积物、废物、污泥","note_cs":"Stanovované analyty: Dibenzo-p-dioxiny a furany (PCDD/F) - 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, suma TCDD, suma PeCCD, suma HxCDD, suma HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, suma TCDF, suma PCDF, suma HxCDF, suma HpCDF; Polychlorované bifenyly (PCB) - trichlorované, tetrachlorované, pentachlorované, hexachlorované, heptachlorované, oktachlorované, nonachlorované a dekachlorované kongenery PCB; Polybromované difenyletery (PBDE) - PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Předmět zkoušení: Zeminy, písky, sedimenty, odpady, kaly","search_text":"Próbki stałe Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych Dibenzo-p-dioksyny i furany (PCDD/F)  Polichlorowane bifenyle (PCB)  Polibromowane difenyloetery (PBDE)  suma PCDD/F, PCB i PBDE Pevné vzorky Stanovení polychlorovaných dibenzo –p-dioxinů a furanů (PCDD/F), vybraných kongenerů polychlorovaných bifenylů (PCB a vybraných kongenerů polybromovaných difenyleterů (PBDE) plynovou chromatografií (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE výpočtem z naměřených hodnot Dibenzo-p-dioxiny a furany (PCDD/F)  Polychlorované bifenyly (PCB)  Polybromované difenyletery (PBDE)  suma PCDD/F, PCB a PBDE SOP 7.01 (EPA 1613) Probki stale Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanow (PCDD/F), wybranych kongenerow polichlorowanych bifenyli (PCB) i wybranych kongenerow polibromowanych difenyloeterow (PBDE) metoda chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartosci zmierzonych Dibenzo-p-dioksyny i furany (PCDD/F)  Polichlorowane bifenyle (PCB)  Polibromowane difenyloetery (PBDE)  suma PCDD/F, PCB i PBDE Pevne vzorky Stanoveni polychlorovanych dibenzo –p-dioxinu a furanu (PCDD/F), vybranych kongeneru polychlorovanych bifenylu (PCB a vybranych kongeneru polybromovanych difenyleteru (PBDE) plynovou chromatografii (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE vypoctem z namerenych hodnot Dibenzo-p-dioxiny a furany (PCDD/F)  Polychlorovane bifenyly (PCB)  Polybromovane difenyletery (PBDE)  suma PCDD/F, PCB a PBDE SOP 7.01 (EPA 1613)","search_en":"Solid samples Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values Dibenzo-p-dioxines and -furanes (PCDD/F)  Polychlorinated biphenyls (PCB)  polybrominated diphenylethers (PBDE)  sum of PCDD/F, PCB and PBDE SOP 7.01 (EPA 1613)","search_zh":"固体样品 气相色谱法（MS/MS、HRMS）测定多氯二苯并对二噁英和呋喃（PCDD/F）、选定的多氯联苯（PCB）同类物和选定的多溴二苯醚（PBDE）同类物，并由测量值计算PCDD/F、PCB和PBDE总和 二苯并对二噁英和呋喃（PCDD/F）  多氯联苯（PCB）  多溴二苯醚（PBDE）  PCDD/F、PCB和PBDE总和 SOP 7.01 (EPA 1613)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"898eb077bf8f022a936fb566","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"11","test_object":"Powietrze, emisje","test_object_en":"Air, emission","test_object_zh":"空气、排放物","test_object_cs":"Ovzduší, emise","methodology":"Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych","methodology_en":"Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values","methodology_zh":"气相色谱法（MS/MS、HRMS）测定多氯二苯并对二噁英和呋喃（PCDD/F）、选定的多氯联苯（PCB）同类物和选定的多溴二苯醚（PBDE）同类物，并由测量值计算PCDD/F、PCB和PBDE总和","methodology_cs":"Stanovení polychlorovaných dibenzo –p-dioxinů a furanů (PCDD/F), vybraných kongenerů polychlorovaných bifenylů (PCB) a vybraných kongenerů polybromovaných difenyleterů (PBDE) plynovou chromatografií (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE výpočtem z naměřených hodnot","parameters":[{"name":"Dibenzo-p-dioksyny i furany (PCDD/F)","range":""},{"name":"Polichlorowane bifenyle (PCB)","range":""},{"name":"Polibromowane difenyloetery (PBDE)","range":""}],"parameters_en":[{"name":"Dibenzo-p-dioxines and -furanes (PCDD/F)","range":""},{"name":"Polychlorinated biphenyls (PCB)","range":""},{"name":"polybrominated diphenylethers (PBDE)","range":""}],"parameters_zh":[{"name":"二苯并对二噁英和呋喃（PCDD/F）","range":""},{"name":"多氯联苯（PCB）","range":""},{"name":"多溴二苯醚（PBDE）","range":""}],"parameters_cs":[{"name":"Dibenzo-p-dioxiny a furany (PCDD/F)","range":""},{"name":"Polychlorované bifenyly (PCB)","range":""},{"name":"Polybromované difenyletery (PBDE)","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma PCDD/F, PCB i PBDE"],"computed_en":["sum of PCDD/F, PCB and PBDE"],"computed_zh":["PCDD/F、PCB和PBDE总和"],"computed_cs":["suma PCDD/F, PCB a PBDE"],"activity":"Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych\nZakres:\nDibenzo-p-dioksyny i furany (PCDD/F)\nPolichlorowane bifenyle (PCB)\nPolibromowane difenyloetery (PBDE)","reference":"SOP 7.04 (ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4+A1)","norm_bases":["SOP 7.04","ČSN EN 1948-2","ČSN EN 1948-3","ČSN EN 1948-4+A1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Oznaczane anality: dibenzo-p-dioksyny i furany (PCDD/F) – 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, suma TCDD, suma PeCCD, suma HxCDD, suma HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, suma TCDF, suma PCDF, suma HxCDF, suma HpCDF; polichlorowane bifenyle (PCB) – trichlorowane, tetrachlorowane, pentachlorowane, heksachlorowane, heptachlorowane, oktachlorowane, nonachlorowane i dekachlorowane kongenery PCB; polibromowane difenyloetery (PBDE) – PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Przedmiot badań: powietrze zewnętrzne, powietrze wewnętrzne, powietrze na stanowiskach pracy, emisje","note_en":"Determined analytes: dibenzo-p-dioxines and -furanes (PCDD/F) – 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, sum of TCDD, sum of PeCCD, sum of HxCDD, sum of HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, sum of TCDF, sum of PCDF, sum of HxCDF, sum of HpCDF; polychlorinated biphenyls (PCB) – trichlorinated, tetrachlorinated, pentachlorinated, hexachlorinated, heptachlorinated, octachlorinated, nonachlorinated and decachlorinated PCB congeners; polybrominated diphenylethers (PBDE) – PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Tested subject: outdoor air, indoor air, working air, emissions","note_zh":"测定的分析物：二苯并对二噁英和呋喃（PCDD/F）——2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD、TCDD总和、PeCCD总和、HxCDD总和、HpCDD总和、2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF、TCDF总和、PCDF总和、HxCDF总和、HpCDF总和；多氯联苯（PCB）——三氯、四氯、五氯、六氯、七氯、八氯、九氯和十氯PCB同类物；多溴二苯醚（PBDE）——PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209。检测对象：室外空气、室内空气、工作场所空气、排放物","note_cs":"Stanovované analyty: Dibenzo-p-dioxiny a furany (PCDD/F) - 2,3,7,8-TCDD, 1,2,3,7,8-PeCDD, 1,2,3,4,7,8-HxCDD, 1,2,3,6,7,8-HxCDD, 1,2,3,7,8,9-HxCDD, 1,2,3,4,6,7,8-HpCDD, 1,2,3,4,6,7,8,9-OCDD, suma TCDD, suma PeCCD, suma HxCDD, suma HpCDD, 2,3,7,8-TCDF, 1,2,3,7,8-PeCDF, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 2,3,4,6,7,8-HxCDF, 1,2,3,7,8,9-HxCDF, 1,2,3,4,6,7,8-HpCDF, 1,2,3,4,7,8,9-HpCDF, 1,2,3,4,6,7,8,9-OCDF, suma TCDF, suma PCDF, suma HxCDF, suma HpCDF; Polychlorované bifenyly (PCB) - trichlorované, tetrachlorované, pentachlorované, hexachlorované, heptachlorované, oktachlorované, nonachlorované a dekachlorované kongenery PCB; Polybromované difenyletery (PBDE) - PBDE15, PBDE17, PBDE28, PBDE47, PBDE49, PBDE66, PBDE71, PBDE77, PBDE99, PBDE100, PBDE138, PBDE153, PBDE154, PBDE156, PBDE183, PBDE206, PBDE207, PBDE209. Předmět zkoušení: Vnější ovzduší, vnitřní ovzduší, pracovní ovzduší, emise","search_text":"Powietrze, emisje Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanów (PCDD/F), wybranych kongenerów polichlorowanych bifenyli (PCB) i wybranych kongenerów polibromowanych difenyloeterów (PBDE) metodą chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartości zmierzonych Dibenzo-p-dioksyny i furany (PCDD/F)  Polichlorowane bifenyle (PCB)  Polibromowane difenyloetery (PBDE)  suma PCDD/F, PCB i PBDE Ovzduší, emise Stanovení polychlorovaných dibenzo –p-dioxinů a furanů (PCDD/F), vybraných kongenerů polychlorovaných bifenylů (PCB) a vybraných kongenerů polybromovaných difenyleterů (PBDE) plynovou chromatografií (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE výpočtem z naměřených hodnot Dibenzo-p-dioxiny a furany (PCDD/F)  Polychlorované bifenyly (PCB)  Polybromované difenyletery (PBDE)  suma PCDD/F, PCB a PBDE SOP 7.04 (ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4+A1) Powietrze, emisje Oznaczanie polichlorowanych dibenzo-p-dioksyn i furanow (PCDD/F), wybranych kongenerow polichlorowanych bifenyli (PCB) i wybranych kongenerow polibromowanych difenyloeterow (PBDE) metoda chromatografii gazowej (MS/MS, HRMS) oraz sumy PCDD/F, PCB i PBDE obliczeniowo z wartosci zmierzonych Dibenzo-p-dioksyny i furany (PCDD/F)  Polichlorowane bifenyle (PCB)  Polibromowane difenyloetery (PBDE)  suma PCDD/F, PCB i PBDE Ovzdusi, emise Stanoveni polychlorovanych dibenzo –p-dioxinu a furanu (PCDD/F), vybranych kongeneru polychlorovanych bifenylu (PCB) a vybranych kongeneru polybromovanych difenyleteru (PBDE) plynovou chromatografii (MS/MS, HRMS) a sumy PCDD/F, PCB a PBDE vypoctem z namerenych hodnot Dibenzo-p-dioxiny a furany (PCDD/F)  Polychlorovane bifenyly (PCB)  Polybromovane difenyletery (PBDE)  suma PCDD/F, PCB a PBDE SOP 7.04 (CSN EN 1948-2; CSN EN 1948-3; CSN EN 1948-4+A1)","search_en":"Air, emission Determination of polychlorinated dibenzo-p-dioxines and furanes (PCDD/F), specified congeners of polychlorinated biphenyls (PCB) and specified congeners of polybrominated diphenylethers (PBDE) by gas chromatography (MS/MS, HRMS) and the sum of PCDD/F, PCB and PBDE by calculation from measured values Dibenzo-p-dioxines and -furanes (PCDD/F)  Polychlorinated biphenyls (PCB)  polybrominated diphenylethers (PBDE)  sum of PCDD/F, PCB and PBDE SOP 7.04 (ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4+A1)","search_zh":"空气、排放物 气相色谱法（MS/MS、HRMS）测定多氯二苯并对二噁英和呋喃（PCDD/F）、选定的多氯联苯（PCB）同类物和选定的多溴二苯醚（PBDE）同类物，并由测量值计算PCDD/F、PCB和PBDE总和 二苯并对二噁英和呋喃（PCDD/F）  多氯联苯（PCB）  多溴二苯醚（PBDE）  PCDD/F、PCB和PBDE总和 SOP 7.04 (ČSN EN 1948-2; ČSN EN 1948-3; ČSN EN 1948-4+A1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"555d894b4b10015f83c0266b","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"12","test_object":"Wody, dializaty z SPMD","test_object_en":"Water, dialyzates from SPMD","test_object_zh":"水、SPMD透析液","test_object_cs":"Vody, dialyzáty z SPMD","methodology":"Oznaczanie węglowodorów C10 do C40 metodą chromatografii gazowej (FID)","methodology_en":"Determination of hydrocarbons C10 to C40 by gas chromatography (FID)","methodology_zh":"气相色谱法（FID）测定C10至C40烃类","methodology_cs":"Stanovení uhlovodíků C10 až C40 plynovou chromatografií (FID)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10 do C40 metodą chromatografii gazowej (FID)","reference":"SOP 10.00 (ČSN EN ISO 9377-2)","norm_bases":["SOP 10.00","ČSN EN ISO 9377-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Przedmiot badań: wody pitne, wody ciepłe, wody butelkowane, wody powierzchniowe, wody podziemne, wody w kąpieliskach, ścieki, dializaty z SPMD","note_en":"Tested subject: drinking water, hot water, bottled water, surface water, underground water, bathing water and waste water, dialyzates from SPMD","note_zh":"检测对象：饮用水、热水、瓶装水、地表水、地下水、浴场水、废水、SPMD透析液","note_cs":"Předmět zkoušení: Vody pitné, vody teplé, vody balené, vody povrchové, vody podzemní, vody ke koupání, vody odpadní, dialyzáty z SPMD","search_text":"Wody, dializaty z SPMD Oznaczanie węglowodorów C10 do C40 metodą chromatografii gazowej (FID) Vody, dialyzáty z SPMD Stanovení uhlovodíků C10 až C40 plynovou chromatografií (FID) SOP 10.00 (ČSN EN ISO 9377-2) Wody, dializaty z SPMD Oznaczanie weglowodorow C10 do C40 metoda chromatografii gazowej (FID) Vody, dialyzaty z SPMD Stanoveni uhlovodiku C10 az C40 plynovou chromatografii (FID) SOP 10.00 (CSN EN ISO 9377-2)","search_en":"Water, dialyzates from SPMD Determination of hydrocarbons C10 to C40 by gas chromatography (FID) SOP 10.00 (ČSN EN ISO 9377-2)","search_zh":"水、SPMD透析液 气相色谱法（FID）测定C10至C40烃类 SOP 10.00 (ČSN EN ISO 9377-2)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a1dd14ef4bb7cb544e3c16c2","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"13","test_object":"Próbki stałe, pasze, materiał biologiczny","test_object_en":"Solid samples, feedstuffs, biological materials","test_object_zh":"固体样品、饲料、生物材料","test_object_cs":"Pevné vzorky, krmiva, biologický materiál","methodology":"Oznaczanie suchej masy metodą wagową i zawartości wody (wilgotności) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of dry matter by gravimetry and water content (moisture content) by calculation from measured values","methodology_zh":"重量法测定干物质，并由测量值计算含水量（湿度）","methodology_cs":"Stanovení sušiny gravimetricky a obsahu vody (vlhkosti) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy metodą wagową i zawartości wody (wilgotności) obliczeniowo z wartości zmierzonych","reference":"SOP 13.00 (ČSN EN 14346, část A)","norm_bases":["SOP 13.00","ČSN EN 14346, část A"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, D","outside_premises":false,"note":"Przedmiot badań: gleby, piaski, osady denne, odpady, szlamy, pasze, materiał zwierzęcy, materiał roślinny","note_en":"Tested subject: soils, sands, sediments, waste, sludge, feedstuffs, animal material, vegetable material","note_zh":"检测对象：土壤、沙、沉积物、废物、污泥、饲料、动物材料、植物材料","note_cs":"Předmět zkoušení: Zeminy, písky, sedimenty, odpady, kaly, krmiva, živočišný materiál, rostlinný materiál","search_text":"Próbki stałe, pasze, materiał biologiczny Oznaczanie suchej masy metodą wagową i zawartości wody (wilgotności) obliczeniowo z wartości zmierzonych Pevné vzorky, krmiva, biologický materiál Stanovení sušiny gravimetricky a obsahu vody (vlhkosti) výpočtem z naměřených hodnot SOP 13.00 (ČSN EN 14346, část A) Probki stale, pasze, material biologiczny Oznaczanie suchej masy metoda wagowa i zawartosci wody (wilgotnosci) obliczeniowo z wartosci zmierzonych Pevne vzorky, krmiva, biologicky material Stanoveni susiny gravimetricky a obsahu vody (vlhkosti) vypoctem z namerenych hodnot SOP 13.00 (CSN EN 14346, cast A)","search_en":"Solid samples, feedstuffs, biological materials Determination of dry matter by gravimetry and water content (moisture content) by calculation from measured values SOP 13.00 (ČSN EN 14346, část A)","search_zh":"固体样品、饲料、生物材料 重量法测定干物质，并由测量值计算含水量（湿度） SOP 13.00 (ČSN EN 14346, část A)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e2c00501c4e64177ba1a7835","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"14","test_object":"Materiał roślinny","test_object_en":"Vegetable materials","test_object_zh":"植物材料","test_object_cs":"Rostlinný materiál","methodology":"Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS)","methodology_en":"Determination of cannabinoids by liquid chromatography (MS)","methodology_zh":"液相色谱法（MS）测定大麻素","methodology_cs":"Stanovení cannabinoidů kapalinovou chromatografií (MS)","parameters":[{"name":"CBD (kannabidiol)","range":""},{"name":"CBDA (kwas kannabidiolowy)","range":""},{"name":"THC (tetrahydrokannabinol)","range":""},{"name":"THCA (kwas tetrahydrokannabinolowy)","range":""},{"name":"CBG (kannabigerol)","range":""},{"name":"CBGA (kwas kannabigerolowy)","range":""},{"name":"CBN (kannabinol)","range":""}],"parameters_en":[{"name":"CBD (cannabidiol)","range":""},{"name":"CBDA (cannabidiolic acid)","range":""},{"name":"THC (tetrahydrocannabinol)","range":""},{"name":"THCA (tetrahydrocannabinolic acid)","range":""},{"name":"CBG (cannabigerol)","range":""},{"name":"CBGA (cannabigerolic acid)","range":""},{"name":"CBN (cannabinol)","range":""}],"parameters_zh":[{"name":"CBD（大麻二酚）","range":""},{"name":"CBDA（大麻二酚酸）","range":""},{"name":"THC（四氢大麻酚）","range":""},{"name":"THCA（四氢大麻酚酸）","range":""},{"name":"CBG（大麻萜酚）","range":""},{"name":"CBGA（大麻萜酚酸）","range":""},{"name":"CBN（大麻酚）","range":""}],"parameters_cs":[{"name":"CBD","range":""},{"name":"CBDA","range":""},{"name":"THC","range":""},{"name":"THCA","range":""},{"name":"CBG","range":""},{"name":"CBGA","range":""},{"name":"CBN","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS)\nZakres:\nCBD (kannabidiol)\nCBDA (kwas kannabidiolowy)\nTHC (tetrahydrokannabinol)\nTHCA (kwas tetrahydrokannabinolowy)\nCBG (kannabigerol)\nCBGA (kwas kannabigerolowy)\nCBN (kannabinol)","reference":"SOP 16.02","norm_bases":["SOP 16.02"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Literatura źródłowa: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233","note_en":"Source literature: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233","note_zh":"参考文献：A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233","note_cs":"Zdrojová literatura: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233","search_text":"Materiał roślinny Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS) CBD (kannabidiol)  CBDA (kwas kannabidiolowy)  THC (tetrahydrokannabinol)  THCA (kwas tetrahydrokannabinolowy)  CBG (kannabigerol)  CBGA (kwas kannabigerolowy)  CBN (kannabinol)  Rostlinný materiál Stanovení cannabinoidů kapalinovou chromatografií (MS) CBD  CBDA  THC  THCA  CBG  CBGA  CBN  SOP 16.02 Material roslinny Oznaczanie kannabinoidow metoda chromatografii cieczowej (MS) CBD (kannabidiol)  CBDA (kwas kannabidiolowy)  THC (tetrahydrokannabinol)  THCA (kwas tetrahydrokannabinolowy)  CBG (kannabigerol)  CBGA (kwas kannabigerolowy)  CBN (kannabinol)  Rostlinny material Stanoveni cannabinoidu kapalinovou chromatografii (MS) CBD  CBDA  THC  THCA  CBG  CBGA  CBN  SOP 16.02","search_en":"Vegetable materials Determination of cannabinoids by liquid chromatography (MS) CBD (cannabidiol)  CBDA (cannabidiolic acid)  THC (tetrahydrocannabinol)  THCA (tetrahydrocannabinolic acid)  CBG (cannabigerol)  CBGA (cannabigerolic acid)  CBN (cannabinol)  SOP 16.02","search_zh":"植物材料 液相色谱法（MS）测定大麻素 CBD（大麻二酚）  CBDA（大麻二酚酸）  THC（四氢大麻酚）  THCA（四氢大麻酚酸）  CBG（大麻萜酚）  CBGA（大麻萜酚酸）  CBN（大麻酚）  SOP 16.02","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"00ef38bc68264ba1b319f640","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"15","test_object":"Żywność i suplementy diety","test_object_en":"Food and food supplements","test_object_zh":"食品和食品补充剂","test_object_cs":"Potraviny a potravinové doplňky","methodology":"Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS)","methodology_en":"Determination of cannabinoids by liquid chromatography (MS)","methodology_zh":"液相色谱法（MS）测定大麻素","methodology_cs":"Stanovení cannabinoidů kapalinovou chromatografií (MS)","parameters":[{"name":"CBD (kannabidiol)","range":""},{"name":"CBDA (kwas kannabidiolowy)","range":""},{"name":"THC (tetrahydrokannabinol)","range":""},{"name":"THCA (kwas tetrahydrokannabinolowy)","range":""},{"name":"CBG (kannabigerol)","range":""},{"name":"CBGA (kwas kannabigerolowy)","range":""},{"name":"CBN (kannabinol)","range":""}],"parameters_en":[{"name":"CBD (cannabidiol)","range":""},{"name":"CBDA (cannabidiolic acid)","range":""},{"name":"THC (tetrahydrocannabinol)","range":""},{"name":"THCA (tetrahydrocannabinolic acid)","range":""},{"name":"CBG (cannabigerol)","range":""},{"name":"CBGA (cannabigerolic acid)","range":""},{"name":"CBN (cannabinol)","range":""}],"parameters_zh":[{"name":"CBD（大麻二酚）","range":""},{"name":"CBDA（大麻二酚酸）","range":""},{"name":"THC（四氢大麻酚）","range":""},{"name":"THCA（四氢大麻酚酸）","range":""},{"name":"CBG（大麻萜酚）","range":""},{"name":"CBGA（大麻萜酚酸）","range":""},{"name":"CBN（大麻酚）","range":""}],"parameters_cs":[{"name":"CBD","range":""},{"name":"CBDA","range":""},{"name":"THC","range":""},{"name":"THCA","range":""},{"name":"CBG","range":""},{"name":"CBGA","range":""},{"name":"CBN","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS)\nZakres:\nCBD (kannabidiol)\nCBDA (kwas kannabidiolowy)\nTHC (tetrahydrokannabinol)\nTHCA (kwas tetrahydrokannabinolowy)\nCBG (kannabigerol)\nCBGA (kwas kannabigerolowy)\nCBN (kannabinol)","reference":"SOP 16.03","norm_bases":["SOP 16.03"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Literatura źródłowa: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Pellegrini M., Marchei E., et al (2004), A rapid and simple procedure for the determinanation of cannabinoids in hemp food products by gas chromatography-mass specrometry, Journal of Pharmaceutical and Biomedical Analysis 36(2005) 939-946, Koch J., delta9 –THC stimulates food intake in Lewis rats Effects on chow, high-fat and sweet hight-fat diets, 2000, Pharmacology, Biochemistry and Behavior 68 (2001) 539-543","note_en":"Source literature: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Pellegrini M., Marchei E., et al (2004), A rapid and simple procedure for the determinanation of cannabinoids in hemp food products by gas chromatography-mass specrometry, Journal of Pharmaceutical and Biomedical Analysis 36(2005) 939-946, Koch J., delta9 –THC stimulates food intake in Lewis rats Effects on chow, high-fat and sweet hight-fat diets, 2000, Pharmacology, Biochemistry and Behavior 68 (2001) 539-543","note_zh":"参考文献：A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Pellegrini M., Marchei E., et al (2004), A rapid and simple procedure for the determinanation of cannabinoids in hemp food products by gas chromatography-mass specrometry, Journal of Pharmaceutical and Biomedical Analysis 36(2005) 939-946, Koch J., delta9 –THC stimulates food intake in Lewis rats Effects on chow, high-fat and sweet hight-fat diets, 2000, Pharmacology, Biochemistry and Behavior 68 (2001) 539-543","note_cs":"Zdrojová literatura: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Pellegrini M., Marchei E., et al (2004), A rapid and simple procedure for the determinanation of cannabinoids in hemp food products by gas chromatography-mass specrometry, Journal of Pharmaceutical and Biomedical Analysis 36(2005) 939-946, Koch J., delta9 –THC stimulates food intake in Lewis rats Effects on chow, high-fat and sweet hight-fat diets, 2000, Pharmacology, Biochemistry and Behavior 68 (2001) 539-543","search_text":"Żywność i suplementy diety Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS) CBD (kannabidiol)  CBDA (kwas kannabidiolowy)  THC (tetrahydrokannabinol)  THCA (kwas tetrahydrokannabinolowy)  CBG (kannabigerol)  CBGA (kwas kannabigerolowy)  CBN (kannabinol)  Potraviny a potravinové doplňky Stanovení cannabinoidů kapalinovou chromatografií (MS) CBD  CBDA  THC  THCA  CBG  CBGA  CBN  SOP 16.03 Zywnosc i suplementy diety Oznaczanie kannabinoidow metoda chromatografii cieczowej (MS) CBD (kannabidiol)  CBDA (kwas kannabidiolowy)  THC (tetrahydrokannabinol)  THCA (kwas tetrahydrokannabinolowy)  CBG (kannabigerol)  CBGA (kwas kannabigerolowy)  CBN (kannabinol)  Potraviny a potravinove doplnky Stanoveni cannabinoidu kapalinovou chromatografii (MS) CBD  CBDA  THC  THCA  CBG  CBGA  CBN  SOP 16.03","search_en":"Food and food supplements Determination of cannabinoids by liquid chromatography (MS) CBD (cannabidiol)  CBDA (cannabidiolic acid)  THC (tetrahydrocannabinol)  THCA (tetrahydrocannabinolic acid)  CBG (cannabigerol)  CBGA (cannabigerolic acid)  CBN (cannabinol)  SOP 16.03","search_zh":"食品和食品补充剂 液相色谱法（MS）测定大麻素 CBD（大麻二酚）  CBDA（大麻二酚酸）  THC（四氢大麻酚）  THCA（四氢大麻酚酸）  CBG（大麻萜酚）  CBGA（大麻萜酚酸）  CBN（大麻酚）  SOP 16.03","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"337e9d4d1275a25070330135","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"16","test_object":"Preparaty kosmetyczne","test_object_en":"Cosmetics","test_object_zh":"化妆品","test_object_cs":"Kosmetické přípravky","methodology":"Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS)","methodology_en":"Determination of cannabinoids by liquid chromatography (MS)","methodology_zh":"液相色谱法（MS）测定大麻素","methodology_cs":"Stanovení cannabinoidů kapalinovou chromatografií (MS)","parameters":[{"name":"CBD (kannabidiol)","range":""},{"name":"CBDA (kwas kannabidiolowy)","range":""},{"name":"THC (tetrahydrokannabinol)","range":""},{"name":"THCA (kwas tetrahydrokannabinolowy)","range":""},{"name":"CBG (kannabigerol)","range":""},{"name":"CBGA (kwas kannabigerolowy)","range":""},{"name":"CBN (kannabinol)","range":""}],"parameters_en":[{"name":"CBD (cannabidiol)","range":""},{"name":"CBDA (cannabidiolic acid)","range":""},{"name":"THC (tetrahydrocannabinol)","range":""},{"name":"THCA (tetrahydrocannabinolic acid)","range":""},{"name":"CBG (cannabigerol)","range":""},{"name":"CBGA (cannabigerolic acid)","range":""},{"name":"CBN (cannabinol)","range":""}],"parameters_zh":[{"name":"CBD（大麻二酚）","range":""},{"name":"CBDA（大麻二酚酸）","range":""},{"name":"THC（四氢大麻酚）","range":""},{"name":"THCA（四氢大麻酚酸）","range":""},{"name":"CBG（大麻萜酚）","range":""},{"name":"CBGA（大麻萜酚酸）","range":""},{"name":"CBN（大麻酚）","range":""}],"parameters_cs":[{"name":"CBD","range":""},{"name":"CBDA","range":""},{"name":"THC","range":""},{"name":"THCA","range":""},{"name":"CBG","range":""},{"name":"CBGA","range":""},{"name":"CBN","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS)\nZakres:\nCBD (kannabidiol)\nCBDA (kwas kannabidiolowy)\nTHC (tetrahydrokannabinol)\nTHCA (kwas tetrahydrokannabinolowy)\nCBG (kannabigerol)\nCBGA (kwas kannabigerolowy)\nCBN (kannabinol)","reference":"SOP 16.05","norm_bases":["SOP 16.05"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":true,"flexibility":"A, B, D","outside_premises":false,"note":"Literatura źródłowa: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Jurado C.,et al (1997), Influence of the cosmetic treatment of hair on drug testing, Int. J. legal Med. 110:159-163","note_en":"Source literature: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Jurado C.,et al (1997), Influence of the cosmetic treatment of hair on drug testing, Int. J. legal Med. 110:159-163","note_zh":"参考文献：A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Jurado C.,et al (1997), Influence of the cosmetic treatment of hair on drug testing, Int. J. legal Med. 110:159-163","note_cs":"Zdrojová literatura: A.A.M. Stolker, J. van Schoonhoven, A.J. de Vries, I. Bobeldijk-Pastorova, W.H.J. Vaes, R. van den Berg (2004): Determination of cannabinoids in cannabis products using liquid chromatography–ion trap mass spektrometry, Journal of Chromatography A, 1058 (2004) 143–151, Roth, N., Moosmann, B. and Auwärter, V. (2013), Development and validation of an LC-MS/MS method for quantification of Δ9-tetrahydrocannabinolic acid A (THCA-A), THC, CBN and CBD in hair. J. Mass Spectrom., 48: 227–233, Jurado C.,et al (1997), Influence of the cosmetic treatment of hair on drug testing, Int. J. legal Med. 110:159-163","search_text":"Preparaty kosmetyczne Oznaczanie kannabinoidów metodą chromatografii cieczowej (MS) CBD (kannabidiol)  CBDA (kwas kannabidiolowy)  THC (tetrahydrokannabinol)  THCA (kwas tetrahydrokannabinolowy)  CBG (kannabigerol)  CBGA (kwas kannabigerolowy)  CBN (kannabinol)  Kosmetické přípravky Stanovení cannabinoidů kapalinovou chromatografií (MS) CBD  CBDA  THC  THCA  CBG  CBGA  CBN  SOP 16.05 Preparaty kosmetyczne Oznaczanie kannabinoidow metoda chromatografii cieczowej (MS) CBD (kannabidiol)  CBDA (kwas kannabidiolowy)  THC (tetrahydrokannabinol)  THCA (kwas tetrahydrokannabinolowy)  CBG (kannabigerol)  CBGA (kwas kannabigerolowy)  CBN (kannabinol)  Kosmeticke pripravky Stanoveni cannabinoidu kapalinovou chromatografii (MS) CBD  CBDA  THC  THCA  CBG  CBGA  CBN  SOP 16.05","search_en":"Cosmetics Determination of cannabinoids by liquid chromatography (MS) CBD (cannabidiol)  CBDA (cannabidiolic acid)  THC (tetrahydrocannabinol)  THCA (tetrahydrocannabinolic acid)  CBG (cannabigerol)  CBGA (cannabigerolic acid)  CBN (cannabinol)  SOP 16.05","search_zh":"化妆品 液相色谱法（MS）测定大麻素 CBD（大麻二酚）  CBDA（大麻二酚酸）  THC（四氢大麻酚）  THCA（四氢大麻酚酸）  CBG（大麻萜酚）  CBGA（大麻萜酚酸）  CBN（大麻酚）  SOP 16.05","categories":["pharma"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8cb18f408e6c5dd9d878019f","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"1","test_object":"Wody pitne, powierzchniowe, podziemne, ścieki","test_object_en":"Drinking, surface, underground and waste water","test_object_zh":"饮用水、地表水、地下水、废水","test_object_cs":"Vody pitné, povrchové, podzemní, odpadní","methodology":"Pobieranie próbek za pomocą membran półprzepuszczalnych (SPMD), próbników pasywnych POCIS i DGT","methodology_en":"Sampling with semipermeable membrane devices (SPMD), passive sampler POCIS and DGT","methodology_zh":"使用半透膜装置（SPMD）、被动采样器POCIS和DGT采样","methodology_cs":"Odběr vzorků pomocí semipermeabilních membrán (SPMD), pasivních vzorkovačů POCIS a DGT","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek za pomocą membran półprzepuszczalnych (SPMD), próbników pasywnych POCIS i DGT","reference":"SOP 1.00 VZ (ČSN EN ISO 5667-23)","norm_bases":["SOP 1.00 VZ","ČSN EN ISO 5667-23"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne, powierzchniowe, podziemne, ścieki Pobieranie próbek za pomocą membran półprzepuszczalnych (SPMD), próbników pasywnych POCIS i DGT Vody pitné, povrchové, podzemní, odpadní Odběr vzorků pomocí semipermeabilních membrán (SPMD), pasivních vzorkovačů POCIS a DGT SOP 1.00 VZ (ČSN EN ISO 5667-23) Wody pitne, powierzchniowe, podziemne, scieki Pobieranie probek za pomoca membran polprzepuszczalnych (SPMD), probnikow pasywnych POCIS i DGT Vody pitne, povrchove, podzemni, odpadni Odber vzorku pomoci semipermeabilnich membran (SPMD), pasivnich vzorkovacu POCIS a DGT SOP 1.00 VZ (CSN EN ISO 5667-23)","search_en":"Drinking, surface, underground and waste water Sampling with semipermeable membrane devices (SPMD), passive sampler POCIS and DGT SOP 1.00 VZ (ČSN EN ISO 5667-23)","search_zh":"饮用水、地表水、地下水、废水 使用半透膜装置（SPMD）、被动采样器POCIS和DGT采样 SOP 1.00 VZ (ČSN EN ISO 5667-23)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"14cbb800b0fe30f330301158","lab_id":"69ad52a4de79e566650fd512","country":"CZ","accr_number":"1665","accr_body":"ČIA","row_label":"2","test_object":"Gleby, piaski, szlamy, odpady","test_object_en":"Soils, sands, sludge, waste","test_object_zh":"土壤、沙、污泥、废物","test_object_cs":"Zeminy, písky, kaly, odpady","methodology":"Ręczne pobieranie próbek odpadów i próbek stałych","methodology_en":"Manual sampling of waste and solid samples","methodology_zh":"废物和固体样品的手工采样","methodology_cs":"Odběr vzorku odpadů a pevných vzorků manuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Ręczne pobieranie próbek odpadów i próbek stałych","reference":"SOP 2.00 VZ (ČSN EN ISO 5667–1; ČSN EN ISO 5667–3; ČSN EN ISO 5667–13; ČSN ISO 5667–14; ČSN ISO 5667–15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN 015110; ČSN 015111; ČSN 015112; ČSN EN 14899; ČSN EN ISO 19458; ČSN EN ISO 3170; Metodický pokyn MŽP ke vzorkování odpadů 2008, 101s)","norm_bases":["SOP 2.00 VZ","ČSN EN ISO 5667–1","ČSN EN ISO 5667–3","ČSN EN ISO 5667–13","ČSN ISO 5667–14","ČSN ISO 5667–15","TNI CEN/TR 15310-1","TNI CEN/TR 15310-2","TNI CEN/TR 15310-3","TNI CEN/TR 15310-4","TNI CEN/TR 15310-5","ČSN 015110","ČSN 015111","ČSN 015112","ČSN EN 14899","ČSN EN ISO 19458","ČSN EN ISO 3170","Metodický pokyn MŽP ke vzorkování odpadů 2008, 101s"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Gleby, piaski, szlamy, odpady Ręczne pobieranie próbek odpadów i próbek stałych Zeminy, písky, kaly, odpady Odběr vzorku odpadů a pevných vzorků manuálně SOP 2.00 VZ (ČSN EN ISO 5667–1; ČSN EN ISO 5667–3; ČSN EN ISO 5667–13; ČSN ISO 5667–14; ČSN ISO 5667–15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN 015110; ČSN 015111; ČSN 015112; ČSN EN 14899; ČSN EN ISO 19458; ČSN EN ISO 3170; Metodický pokyn MŽP ke vzorkování odpadů 2008, 101s) Gleby, piaski, szlamy, odpady Reczne pobieranie probek odpadow i probek stalych Zeminy, pisky, kaly, odpady Odber vzorku odpadu a pevnych vzorku manualne SOP 2.00 VZ (CSN EN ISO 5667–1; CSN EN ISO 5667–3; CSN EN ISO 5667–13; CSN ISO 5667–14; CSN ISO 5667–15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; CSN 015110; CSN 015111; CSN 015112; CSN EN 14899; CSN EN ISO 19458; CSN EN ISO 3170; Metodicky pokyn MZP ke vzorkovani odpadu 2008, 101s)","search_en":"Soils, sands, sludge, waste Manual sampling of waste and solid samples SOP 2.00 VZ (ČSN EN ISO 5667–1; ČSN EN ISO 5667–3; ČSN EN ISO 5667–13; ČSN ISO 5667–14; ČSN ISO 5667–15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN 015110; ČSN 015111; ČSN 015112; ČSN EN 14899; ČSN EN ISO 19458; ČSN EN ISO 3170; Metodický pokyn MŽP ke vzorkování odpadů 2008, 101s)","search_zh":"土壤、沙、污泥、废物 废物和固体样品的手工采样 SOP 2.00 VZ (ČSN EN ISO 5667–1; ČSN EN ISO 5667–3; ČSN EN ISO 5667–13; ČSN ISO 5667–14; ČSN ISO 5667–15; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN 015110; ČSN 015111; ČSN 015112; ČSN EN 14899; ČSN EN ISO 19458; ČSN EN ISO 3170; Metodický pokyn MŽP ke vzorkování odpadů 2008, 101s)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}