🇨🇿 Fakultní nemocnice Olomouc PL

ČIA 1607 • Olomouc, Czech Republic • 8 methods

Microbiology

Fakultní nemocnice Olomouc is a laboratory accredited by ČIA under number 1607 (Olomouc, Czech Republic). Its accreditation scope covers 8 test methods in the following areas: Microbiology. Test objects include: Steriliser, Biological indicators Geobacillus stearothermophilus for steam and…, Indoor air, Surfaces, objects, hands.

At a glance

  • Accreditation number: ČIA 1607
  • Methods in scope: 8
  • Types of test objects: 6
  • City: Olomouc, Czech Republic
  • Valid until: 19-12-2028
Accreditation number
1607
Accreditation body
ČIA
Address
Puškinova 214/2, 779 00 Olomouc
City
Olomouc, Czech Republic
Division
Laboratorium Badawcze Oddziału Higieny Szpitalnej
Valid until
19-12-2028

What this laboratory tests (6)

Certificate information

Certificate date
19.12.2023

Accreditation scope — test methods (8)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Steriliser Testing of the efficacy of the sterilisation cycle of a steam steriliser with non-biological and biological systems
Regulated area: Tests
SOP-01 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-3; ČSN EN ISO 11140-6; AHEM č. 1/2014)
2 Steriliser Testing of the efficacy of the sterilisation cycle of a hot-air steriliser with non-biological and biological systems
Regulated area: Tests
SOP-02 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-4; AHEM č. 1/2014)
3 Steriliser Testing of the efficacy of the sterilisation cycle of a formaldehyde steriliser with non-biological and biological systems
Regulated area: Tests
SOP-03 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-5; ČSN EN ISO 11140-6; AHEM č. 1/2014)
4 Washer-disinfectors Testing of the efficacy of the machine washing process with chemical tests
Regulated area: Tests
SOP-04 (ČSN EN ISO 15883-5; ČSN EN ISO 15883-1; ČSN EN ISO 15883-2; ČSN EN ISO 15883-4 ed. 3)
5 Biological indicators Geobacillus stearothermophilus for steam and formaldehyde sterilisers and Bacillus atrophaeus for hot-air sterilisers Culture examination of biological sterilisation indicators exposed during testing of the efficacy of the sterilisation cycle
Regulated area: Tests
SOP-05 (AHEM č. 1/2014)
6 Swabs and imprints from surfaces, objects and hands, indoor air samples Culture examination and identification of microorganisms
Regulated area: Tests
SOP-07 (AHEM příloha č. 7/1992; AHEM č. 4/2021)
7 Indoor air Determination of particle count with a particle counter
Regulated area: Tests
SOP-08 (ČSN EN ISO 14644-1; VYR 32)
8 Surfaces, objects, hands Collection of swabs and imprints for microbiological examination
Regulated area: Sampling
SOP 06 (AHEM příloha č. 7/1992)

Reference standards (24)

AHEM příloha č. 7/1992
AHEM č. 1/2014
AHEM č. 4/2021
SOP 06
SOP-01
SOP-02
SOP-03
SOP-04
SOP-05
SOP-07
SOP-08
VYR 32
Vyhláška č. 306/2012 Sb.
ČSN EN ISO 11138-1
ČSN EN ISO 11138-3
ČSN EN ISO 11138-4
ČSN EN ISO 11138-5
ČSN EN ISO 11140-1
ČSN EN ISO 11140-6
ČSN EN ISO 14644-1
ČSN EN ISO 15883-1
ČSN EN ISO 15883-2
ČSN EN ISO 15883-4 ed. 3
ČSN EN ISO 15883-5

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1607