🇨🇿 Fakultní nemocnice Olomouc PL
Microbiology
Fakultní nemocnice Olomouc is a laboratory accredited by ČIA under number 1607 (Olomouc, Czech Republic). Its accreditation scope covers 8 test methods in the following areas: Microbiology. Test objects include: Steriliser, Biological indicators Geobacillus stearothermophilus for steam and…, Indoor air, Surfaces, objects, hands.
At a glance
- Accreditation number: ČIA 1607
- Methods in scope: 8
- Types of test objects: 6
- City: Olomouc, Czech Republic
- Valid until: 19-12-2028
- Accreditation number
- 1607
- Accreditation body
- ČIA
- Address
- Puškinova 214/2, 779 00 Olomouc
- City
- Olomouc, Czech Republic
- Division
- Laboratorium Badawcze Oddziału Higieny Szpitalnej
- Valid until
- 19-12-2028
What this laboratory tests (6)
- Steriliser — 3 methods
- Biological indicators Geobacillus stearothermophilus for steam and formaldehyde sterilisers and Bacillus atrophaeus for hot-air sterilisers — 1 method
- Indoor air — 1 method
- Surfaces, objects, hands — 1 method
- Swabs and imprints from surfaces, objects and hands, indoor air samples — 1 method
- Washer-disinfectors — 1 method
Certificate information
- Certificate date
- 19.12.2023
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Steriliser | Testing of the efficacy of the sterilisation cycle of a steam steriliser with non-biological and biological systems Regulated area: Tests |
SOP-01 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-3; ČSN EN ISO 11140-6; AHEM č. 1/2014) | ||
| 2 | Steriliser | Testing of the efficacy of the sterilisation cycle of a hot-air steriliser with non-biological and biological systems Regulated area: Tests |
SOP-02 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-4; AHEM č. 1/2014) | ||
| 3 | Steriliser | Testing of the efficacy of the sterilisation cycle of a formaldehyde steriliser with non-biological and biological systems Regulated area: Tests |
SOP-03 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-5; ČSN EN ISO 11140-6; AHEM č. 1/2014) | ||
| 4 | Washer-disinfectors | Testing of the efficacy of the machine washing process with chemical tests Regulated area: Tests |
SOP-04 (ČSN EN ISO 15883-5; ČSN EN ISO 15883-1; ČSN EN ISO 15883-2; ČSN EN ISO 15883-4 ed. 3) | ||
| 5 | Biological indicators Geobacillus stearothermophilus for steam and formaldehyde sterilisers and Bacillus atrophaeus for hot-air sterilisers | Culture examination of biological sterilisation indicators exposed during testing of the efficacy of the sterilisation cycle Regulated area: Tests |
SOP-05 (AHEM č. 1/2014) | ||
| 6 | Swabs and imprints from surfaces, objects and hands, indoor air samples | Culture examination and identification of microorganisms Regulated area: Tests |
SOP-07 (AHEM příloha č. 7/1992; AHEM č. 4/2021) | ||
| 7 | Indoor air | Determination of particle count with a particle counter Regulated area: Tests |
SOP-08 (ČSN EN ISO 14644-1; VYR 32) | ||
| 8 | Surfaces, objects, hands | Collection of swabs and imprints for microbiological examination Regulated area: Sampling |
SOP 06 (AHEM příloha č. 7/1992) | ||
Reference standards (24)
AHEM příloha č. 7/1992
AHEM č. 1/2014
AHEM č. 4/2021
SOP 06
SOP-01
SOP-02
SOP-03
SOP-04
SOP-05
SOP-07
SOP-08
VYR 32
Vyhláška č. 306/2012 Sb.
ČSN EN ISO 11138-1
ČSN EN ISO 11138-3
ČSN EN ISO 11138-4
ČSN EN ISO 11138-5
ČSN EN ISO 11140-1
ČSN EN ISO 11140-6
ČSN EN ISO 14644-1
ČSN EN ISO 15883-1
ČSN EN ISO 15883-2
ČSN EN ISO 15883-4 ed. 3