{"lab":{"_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","address":"Puškinova 214/2, 779 00 Olomouc","categories":["microbiology"],"city":"Olomouc","imported_at":"2026-03-08T10:42:44.590Z","methods_count":8,"name":"Fakultní nemocnice Olomouc","parse_status":"parsed","parse_version":5,"pdf_files":["1607_679_2023_CS.pdf","1607_679_2023_EN.pdf"],"scope_summary":"Badanie skuteczności cyklu sterylizacji sterylizatorów, procesu mycia i dezynfekcji w myciu maszynowym, badanie hodowlane biologicznych wskaźników sterylizacji, pobieranie wymazów i odcisków z powierzchni, badanie mikrobiologiczne pobranych próbek i próbek powietrza wewnętrznego, oznaczanie liczby cząstek licznikiem cząstek.","search_text":"fakultní nemocnice olomouc puškinova 214/2, 779 00 olomouc 1607","status":"active","updated_at":"2026-03-08T14:52:13.781Z","valid_from":"","valid_until":"19-12-2028","website":"www.fnol.cz","location":{"type":"Point","coordinates":[17.2509,49.5938]},"email_confidence":"high","email_mx":true,"email_source":"https://www.fnol.cz","map_coord":[49.581843,17.237136],"map_geo":"nominatim-street","certificate_date":"19.12.2023","certificate_no":"679/2023","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badanie skuteczności cyklu sterylizacji sterylizatorów, procesu mycia i dezynfekcji w myciu maszynowym, badanie hodowlane biologicznych wskaźników sterylizacji, pobieranie wymazów i odcisków z powierzchni, badanie mikrobiologiczne pobranych próbek i próbek powietrza wewnętrznego, oznaczanie liczby cząstek licznikiem cząstek.","en":"Testing of the efficacy of the sterilisation cycle of sterilisers and of the washing and disinfection process of machine washing, culture examination of biological sterilisation indicators, collection of swabs and imprints from surfaces, microbiological examination of collected samples and indoor air samples, determination of particle count with a particle counter.","zh":"灭菌器灭菌周期及机器清洗消毒过程有效性的检测，灭菌生物指示物的培养检查，表面擦拭和印迹采样，所采样品和室内空气样品的微生物检查，粒子计数器测定粒子数。","cs":"Zkoušení účinnosti sterilizačního cyklu sterilizátorů, mycího a dezinfekčního procesu strojového mytí, kultivační vyšetření biologických indikátorů sterilizace, odběr stěrů a otisků z povrchů, mikrobiologické vyšetření odebraných vzorků a vzorků vnitřního ovzduší, stanovení počtu částic čítačem částic."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze Oddziału Higieny Szpitalnej","lab_division_cs":"Zkušební laboratoř Oddělení nemocniční hygieny","lab_division_en":"Testing Laboratory of the Department of Hospital Hygiene","lab_division_zh":"医院卫生科检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"AHEM","pl":"Acta hygienica, epidemiologica et microbiologica (czasopismo)","en":"Acta hygienica, epidemiologica et microbiologica","zh":"《卫生、流行病与微生物学学报》","cs":"Acta hygienica, epidemiologica et microbiologica"},{"abbr":"VYR","pl":"Wytwarzanie produktów leczniczych","en":"Manufacture of medicinal products","zh":"药品生产","cs":"Výroba léčiv"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"8132250ea0feb360675b46913102a9a7c2b53906b6e6c46e4bdbc540ce74f673","source_pdf_url":"https://www.cai.cz/OA/pdf/P679_2023_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"f67a3482e5ab72dd000c4a13","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"1","test_object":"Sterylizator","test_object_en":"Steriliser","test_object_zh":"灭菌器","test_object_cs":"Sterilizační přístroj","methodology":"Badanie skuteczności cyklu sterylizacji sterylizatora parowego wskaźnikami niebiologicznymi i biologicznymi","methodology_en":"Testing of the efficacy of the sterilisation cycle of a steam steriliser with non-biological and biological systems","methodology_zh":"用非生物和生物系统检测蒸汽灭菌器灭菌周期的有效性","methodology_cs":"Zkoušení účinnosti sterilizačního cyklu parního sterilizátoru nebiologickými a biologickými systémy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie skuteczności cyklu sterylizacji sterylizatora parowego wskaźnikami niebiologicznymi i biologicznymi","reference":"SOP-01 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-3; ČSN EN ISO 11140-6; AHEM č. 1/2014)","norm_bases":["SOP-01","Vyhláška č. 306/2012 Sb.","ČSN EN ISO 11140-1","ČSN EN ISO 11138-1","ČSN EN ISO 11138-3","ČSN EN ISO 11140-6","AHEM č. 1/2014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizator Badanie skuteczności cyklu sterylizacji sterylizatora parowego wskaźnikami niebiologicznymi i biologicznymi Sterilizační přístroj Zkoušení účinnosti sterilizačního cyklu parního sterilizátoru nebiologickými a biologickými systémy SOP-01 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-3; ČSN EN ISO 11140-6; AHEM č. 1/2014) Sterylizator Badanie skutecznosci cyklu sterylizacji sterylizatora parowego wskaznikami niebiologicznymi i biologicznymi Sterilizacni pristroj Zkouseni ucinnosti sterilizacniho cyklu parniho sterilizatoru nebiologickymi a biologickymi systemy SOP-01 (Vyhlaska c. 306/2012 Sb.; CSN EN ISO 11140-1; CSN EN ISO 11138-1; CSN EN ISO 11138-3; CSN EN ISO 11140-6; AHEM c. 1/2014)","search_en":"Steriliser Testing of the efficacy of the sterilisation cycle of a steam steriliser with non-biological and biological systems SOP-01 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-3; ČSN EN ISO 11140-6; AHEM č. 1/2014)","search_zh":"灭菌器 用非生物和生物系统检测蒸汽灭菌器灭菌周期的有效性 SOP-01 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-3; ČSN EN ISO 11140-6; AHEM č. 1/2014)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bbf41628ff105e06e0f14c6e","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"2","test_object":"Sterylizator","test_object_en":"Steriliser","test_object_zh":"灭菌器","test_object_cs":"Sterilizační přístroj","methodology":"Badanie skuteczności cyklu sterylizacji sterylizatora na suche gorące powietrze wskaźnikami niebiologicznymi i biologicznymi","methodology_en":"Testing of the efficacy of the sterilisation cycle of a hot-air steriliser with non-biological and biological systems","methodology_zh":"用非生物和生物系统检测干热灭菌器灭菌周期的有效性","methodology_cs":"Zkoušení účinnosti sterilizačního cyklu horkovzdušného sterilizátoru nebiologickými a biologickými systémy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie skuteczności cyklu sterylizacji sterylizatora na suche gorące powietrze wskaźnikami niebiologicznymi i biologicznymi","reference":"SOP-02 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-4; AHEM č. 1/2014)","norm_bases":["SOP-02","Vyhláška č. 306/2012 Sb.","ČSN EN ISO 11140-1","ČSN EN ISO 11138-1","ČSN EN ISO 11138-4","AHEM č. 1/2014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizator Badanie skuteczności cyklu sterylizacji sterylizatora na suche gorące powietrze wskaźnikami niebiologicznymi i biologicznymi Sterilizační přístroj Zkoušení účinnosti sterilizačního cyklu horkovzdušného sterilizátoru nebiologickými a biologickými systémy SOP-02 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-4; AHEM č. 1/2014) Sterylizator Badanie skutecznosci cyklu sterylizacji sterylizatora na suche gorace powietrze wskaznikami niebiologicznymi i biologicznymi Sterilizacni pristroj Zkouseni ucinnosti sterilizacniho cyklu horkovzdusneho sterilizatoru nebiologickymi a biologickymi systemy SOP-02 (Vyhlaska c. 306/2012 Sb.; CSN EN ISO 11140-1; CSN EN ISO 11138-1; CSN EN ISO 11138-4; AHEM c. 1/2014)","search_en":"Steriliser Testing of the efficacy of the sterilisation cycle of a hot-air steriliser with non-biological and biological systems SOP-02 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-4; AHEM č. 1/2014)","search_zh":"灭菌器 用非生物和生物系统检测干热灭菌器灭菌周期的有效性 SOP-02 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-4; AHEM č. 1/2014)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cab850dd2e06269246874e33","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"3","test_object":"Sterylizator","test_object_en":"Steriliser","test_object_zh":"灭菌器","test_object_cs":"Sterilizační přístroj","methodology":"Badanie skuteczności cyklu sterylizacji sterylizatora formaldehydowego wskaźnikami niebiologicznymi i biologicznymi","methodology_en":"Testing of the efficacy of the sterilisation cycle of a formaldehyde steriliser with non-biological and biological systems","methodology_zh":"用非生物和生物系统检测甲醛灭菌器灭菌周期的有效性","methodology_cs":"Zkoušení účinnosti sterilizačního cyklu formaldehydového sterilizátoru nebiologickými a biologickými systémy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie skuteczności cyklu sterylizacji sterylizatora formaldehydowego wskaźnikami niebiologicznymi i biologicznymi","reference":"SOP-03 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-5; ČSN EN ISO 11140-6; AHEM č. 1/2014)","norm_bases":["SOP-03","Vyhláška č. 306/2012 Sb.","ČSN EN ISO 11140-1","ČSN EN ISO 11138-1","ČSN EN ISO 11138-5","ČSN EN ISO 11140-6","AHEM č. 1/2014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Sterylizator Badanie skuteczności cyklu sterylizacji sterylizatora formaldehydowego wskaźnikami niebiologicznymi i biologicznymi Sterilizační přístroj Zkoušení účinnosti sterilizačního cyklu formaldehydového sterilizátoru nebiologickými a biologickými systémy SOP-03 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-5; ČSN EN ISO 11140-6; AHEM č. 1/2014) Sterylizator Badanie skutecznosci cyklu sterylizacji sterylizatora formaldehydowego wskaznikami niebiologicznymi i biologicznymi Sterilizacni pristroj Zkouseni ucinnosti sterilizacniho cyklu formaldehydoveho sterilizatoru nebiologickymi a biologickymi systemy SOP-03 (Vyhlaska c. 306/2012 Sb.; CSN EN ISO 11140-1; CSN EN ISO 11138-1; CSN EN ISO 11138-5; CSN EN ISO 11140-6; AHEM c. 1/2014)","search_en":"Steriliser Testing of the efficacy of the sterilisation cycle of a formaldehyde steriliser with non-biological and biological systems SOP-03 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-5; ČSN EN ISO 11140-6; AHEM č. 1/2014)","search_zh":"灭菌器 用非生物和生物系统检测甲醛灭菌器灭菌周期的有效性 SOP-03 (Vyhláška č. 306/2012 Sb.; ČSN EN ISO 11140-1; ČSN EN ISO 11138-1; ČSN EN ISO 11138-5; ČSN EN ISO 11140-6; AHEM č. 1/2014)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bba369168f5d9c1809215bca","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"4","test_object":"Myjnie-dezynfektory","test_object_en":"Washer-disinfectors","test_object_zh":"清洗消毒器","test_object_cs":"Mycí a dezinfekční automaty","methodology":"Badanie skuteczności procesu mycia maszynowego testami chemicznymi","methodology_en":"Testing of the efficacy of the machine washing process with chemical tests","methodology_zh":"用化学测试检测机器清洗过程的有效性","methodology_cs":"Zkoušení účinnosti mycího procesu strojového mytí chemickými testy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie skuteczności procesu mycia maszynowego testami chemicznymi","reference":"SOP-04 (ČSN EN ISO 15883-5; ČSN EN ISO 15883-1; ČSN EN ISO 15883-2; ČSN EN ISO 15883-4 ed. 3)","norm_bases":["SOP-04","ČSN EN ISO 15883-5","ČSN EN ISO 15883-1","ČSN EN ISO 15883-2","ČSN EN ISO 15883-4 ed. 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Myjnie-dezynfektory Badanie skuteczności procesu mycia maszynowego testami chemicznymi Mycí a dezinfekční automaty Zkoušení účinnosti mycího procesu strojového mytí chemickými testy SOP-04 (ČSN EN ISO 15883-5; ČSN EN ISO 15883-1; ČSN EN ISO 15883-2; ČSN EN ISO 15883-4 ed. 3) Myjnie-dezynfektory Badanie skutecznosci procesu mycia maszynowego testami chemicznymi Myci a dezinfekcni automaty Zkouseni ucinnosti myciho procesu strojoveho myti chemickymi testy SOP-04 (CSN EN ISO 15883-5; CSN EN ISO 15883-1; CSN EN ISO 15883-2; CSN EN ISO 15883-4 ed. 3)","search_en":"Washer-disinfectors Testing of the efficacy of the machine washing process with chemical tests SOP-04 (ČSN EN ISO 15883-5; ČSN EN ISO 15883-1; ČSN EN ISO 15883-2; ČSN EN ISO 15883-4 ed. 3)","search_zh":"清洗消毒器 用化学测试检测机器清洗过程的有效性 SOP-04 (ČSN EN ISO 15883-5; ČSN EN ISO 15883-1; ČSN EN ISO 15883-2; ČSN EN ISO 15883-4 ed. 3)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2573dcd1e32e91a0d04f79b","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"5","test_object":"Wskaźniki biologiczne Geobacillus stearothermophilus dla sterylizatorów parowych i formaldehydowych oraz Bacillus atrophaeus dla sterylizatorów na suche gorące powietrze","test_object_en":"Biological indicators Geobacillus stearothermophilus for steam and formaldehyde sterilisers and Bacillus atrophaeus for hot-air sterilisers","test_object_zh":"用于蒸汽和甲醛灭菌器的嗜热脂肪地芽孢杆菌生物指示物及用于干热灭菌器的萎缩芽孢杆菌生物指示物","test_object_cs":"Biologické indikátory Geobacillus stearothermophilus pro parní a formaldehydové sterilizátory a Bacillus atrophaeus pro horkovzdušné sterilizátory","methodology":"Badanie hodowlane biologicznych wskaźników sterylizacji eksponowanych podczas badania skuteczności cyklu sterylizacji","methodology_en":"Culture examination of biological sterilisation indicators exposed during testing of the efficacy of the sterilisation cycle","methodology_zh":"对灭菌周期有效性检测中暴露的灭菌生物指示物进行培养检查","methodology_cs":"Kultivační vyšetření biologických indikátorů sterilizace exponovaných při zkoušení účinnosti sterilizačního cyklu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie hodowlane biologicznych wskaźników sterylizacji eksponowanych podczas badania skuteczności cyklu sterylizacji","reference":"SOP-05 (AHEM č. 1/2014)","norm_bases":["SOP-05","AHEM č. 1/2014"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wskaźniki biologiczne Geobacillus stearothermophilus dla sterylizatorów parowych i formaldehydowych oraz Bacillus atrophaeus dla sterylizatorów na suche gorące powietrze Badanie hodowlane biologicznych wskaźników sterylizacji eksponowanych podczas badania skuteczności cyklu sterylizacji Biologické indikátory Geobacillus stearothermophilus pro parní a formaldehydové sterilizátory a Bacillus atrophaeus pro horkovzdušné sterilizátory Kultivační vyšetření biologických indikátorů sterilizace exponovaných při zkoušení účinnosti sterilizačního cyklu SOP-05 (AHEM č. 1/2014) Wskazniki biologiczne Geobacillus stearothermophilus dla sterylizatorow parowych i formaldehydowych oraz Bacillus atrophaeus dla sterylizatorow na suche gorace powietrze Badanie hodowlane biologicznych wskaznikow sterylizacji eksponowanych podczas badania skutecznosci cyklu sterylizacji Biologicke indikatory Geobacillus stearothermophilus pro parni a formaldehydove sterilizatory a Bacillus atrophaeus pro horkovzdusne sterilizatory Kultivacni vysetreni biologickych indikatoru sterilizace exponovanych pri zkouseni ucinnosti sterilizacniho cyklu SOP-05 (AHEM c. 1/2014)","search_en":"Biological indicators Geobacillus stearothermophilus for steam and formaldehyde sterilisers and Bacillus atrophaeus for hot-air sterilisers Culture examination of biological sterilisation indicators exposed during testing of the efficacy of the sterilisation cycle SOP-05 (AHEM č. 1/2014)","search_zh":"用于蒸汽和甲醛灭菌器的嗜热脂肪地芽孢杆菌生物指示物及用于干热灭菌器的萎缩芽孢杆菌生物指示物 对灭菌周期有效性检测中暴露的灭菌生物指示物进行培养检查 SOP-05 (AHEM č. 1/2014)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"995529792658cb74eabb66e3","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"6","test_object":"Wymazy i odciski z powierzchni, przedmiotów i rąk, próbki powietrza wewnętrznego","test_object_en":"Swabs and imprints from surfaces, objects and hands, indoor air samples","test_object_zh":"表面、物品和手部的擦拭及印迹样品，室内空气样品","test_object_cs":"Stěry a otisky povrchů ploch, předmětů a rukou, vzorky vnitřního ovzduší","methodology":"Badanie hodowlane i identyfikacja drobnoustrojów","methodology_en":"Culture examination and identification of microorganisms","methodology_zh":"微生物的培养检查和鉴定","methodology_cs":"Kultivační vyšetření a identifikace mikroorganismů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie hodowlane i identyfikacja drobnoustrojów","reference":"SOP-07 (AHEM příloha č. 7/1992; AHEM č. 4/2021)","norm_bases":["SOP-07","AHEM příloha č. 7/1992","AHEM č. 4/2021"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wymazy i odciski z powierzchni, przedmiotów i rąk, próbki powietrza wewnętrznego Badanie hodowlane i identyfikacja drobnoustrojów Stěry a otisky povrchů ploch, předmětů a rukou, vzorky vnitřního ovzduší Kultivační vyšetření a identifikace mikroorganismů SOP-07 (AHEM příloha č. 7/1992; AHEM č. 4/2021) Wymazy i odciski z powierzchni, przedmiotow i rak, probki powietrza wewnetrznego Badanie hodowlane i identyfikacja drobnoustrojow Stery a otisky povrchu ploch, predmetu a rukou, vzorky vnitrniho ovzdusi Kultivacni vysetreni a identifikace mikroorganismu SOP-07 (AHEM priloha c. 7/1992; AHEM c. 4/2021)","search_en":"Swabs and imprints from surfaces, objects and hands, indoor air samples Culture examination and identification of microorganisms SOP-07 (AHEM příloha č. 7/1992; AHEM č. 4/2021)","search_zh":"表面、物品和手部的擦拭及印迹样品，室内空气样品 微生物的培养检查和鉴定 SOP-07 (AHEM příloha č. 7/1992; AHEM č. 4/2021)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef12a9f19278a6b39f2f4852","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"7","test_object":"Powietrze wewnętrzne","test_object_en":"Indoor air","test_object_zh":"室内空气","test_object_cs":"Vnitřní ovzduší","methodology":"Oznaczanie liczby cząstek licznikiem cząstek","methodology_en":"Determination of particle count with a particle counter","methodology_zh":"粒子计数器测定粒子数","methodology_cs":"Stanovení počtu částic čítačem částic","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby cząstek licznikiem cząstek","reference":"SOP-08 (ČSN EN ISO 14644-1; VYR 32)","norm_bases":["SOP-08","ČSN EN ISO 14644-1","VYR 32"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze wewnętrzne Oznaczanie liczby cząstek licznikiem cząstek Vnitřní ovzduší Stanovení počtu částic čítačem částic SOP-08 (ČSN EN ISO 14644-1; VYR 32) Powietrze wewnetrzne Oznaczanie liczby czastek licznikiem czastek Vnitrni ovzdusi Stanoveni poctu castic citacem castic SOP-08 (CSN EN ISO 14644-1; VYR 32)","search_en":"Indoor air Determination of particle count with a particle counter SOP-08 (ČSN EN ISO 14644-1; VYR 32)","search_zh":"室内空气 粒子计数器测定粒子数 SOP-08 (ČSN EN ISO 14644-1; VYR 32)","categories":["other"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a6e77f9ce3b0db46e77d6955","lab_id":"69ad52a4de79e566650fd4ca","country":"CZ","accr_number":"1607","accr_body":"ČIA","row_label":"1","test_object":"Powierzchnie, przedmioty, ręce","test_object_en":"Surfaces, objects, hands","test_object_zh":"表面、物品、手部","test_object_cs":"Plochy, předměty, ruce","methodology":"Pobieranie wymazu i odcisku do badania mikrobiologicznego","methodology_en":"Collection of swabs and imprints for microbiological examination","methodology_zh":"采集擦拭和印迹样品用于微生物检查","methodology_cs":"Odběr stěru a otisku k mikrobiologickému vyšetření","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie wymazu i odcisku do badania mikrobiologicznego","reference":"SOP 06 (AHEM příloha č. 7/1992)","norm_bases":["SOP 06","AHEM příloha č. 7/1992"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powierzchnie, przedmioty, ręce Pobieranie wymazu i odcisku do badania mikrobiologicznego Plochy, předměty, ruce Odběr stěru a otisku k mikrobiologickému vyšetření SOP 06 (AHEM příloha č. 7/1992) Powierzchnie, przedmioty, rece Pobieranie wymazu i odcisku do badania mikrobiologicznego Plochy, predmety, ruce Odber steru a otisku k mikrobiologickemu vysetreni SOP 06 (AHEM priloha c. 7/1992)","search_en":"Surfaces, objects, hands Collection of swabs and imprints for microbiological examination SOP 06 (AHEM příloha č. 7/1992)","search_zh":"表面、物品、手部 采集擦拭和印迹样品用于微生物检查 SOP 06 (AHEM příloha č. 7/1992)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}