🇨🇿 Vysoká škola báňská – Technická univerzita Ostrava PL
Environment
Vysoká škola báňská – Technická univerzita Ostrava is a laboratory accredited by ČIA under number 1588 (Ostrava - Poruba, Czech Republic). Its accreditation scope covers 9 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: condensation method, psychrometrically, flame ionisation detection, gravimetry.
At a glance
- Accreditation number: ČIA 1588
- Methods in scope: 9
- Types of test objects: 1
- Techniques used: 6
- City: Ostrava - Poruba, Czech Republic
- Valid until: 12-06-2028
- Accreditation number
- 1588
- Accreditation body
- ČIA
- Address
- 17. listopadu 2172/15, 708 00 Ostrava - Poruba
- City
- Ostrava - Poruba, Czech Republic
- Division
- Pracownia Eksploatacji i Diagnostyki Urządzeń Cieplno-Energetycznych
- Valid until
- 12-06-2028
What this laboratory tests (1)
- Emissions — 9 methods
Analytical techniques used (6)
- condensation method, psychrometrically — 1 method
- flame ionisation detection — 1 method
- gravimetry — 1 method
- isokinetic sampling with automatic isokinetic control — 1 method
- non-dispersive infrared spectroscopy — 1 method
- paramagnetic method — 1 method
Certificate information
- Certificate date
- 12.06.2023
Accreditation scope — test methods (9)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of flow velocity and volume flow rate Regulated area: Tests |
SOP 3 (ČSN ISO 10780) | ||
| 2 | Emissions | Determination of gas moisture Regulated area: Tests |
condensation method, psychrometrically | SOP 1A (ČSN EN 14790) | |
| 3 | Emissions | Determination of volume concentration of oxygen (O2) by automated analyser Regulated area: Tests |
paramagnetic method | SOP 2A (ČSN EN 14789) | |
| 4 | Emissions | Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO) Regulated area: Tests |
non-dispersive infrared spectroscopy | SOP 2B (ČSN ISO 7935; ČSN EN 15058; ČSN ISO 10849) | |
| 5 | Emissions | Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers Regulated area: Tests |
flame ionisation detection | SOP 2C (ČSN EN 12619) | |
| 6 | Emissions | Determination of mass concentration of particulate pollutants Regulated area: Tests |
gravimetry | SOP 1B (ČSN EN 13284-1) | |
| 7 | Emissions | Determination of mass concentration of gases and vapours (HCl, HF) by calculation from measured values Hydrogen chloride (HCl) Hydrogen fluoride (HF) Regulated area: Tests |
SOP 4 (ČSN EN 1911; ČSN P CEN/TS 17340) | ||
| 8 | Emissions | Sampling of particulate pollutants Regulated area: Sampling |
isokinetic sampling with automatic isokinetic control | SOP 1V (ČSN EN 13284-1) | |
| 9 | Emissions | Sampling of gases and vapours by absorption into liquid (HCl, HF) Regulated area: Sampling |
SOP 4V (ČSN EN 1911; ČSN P CEN/TS 17340) | ||
Reference standards (19)
SOP 1A
SOP 1B
SOP 1V
SOP 2A
SOP 2B
SOP 2C
SOP 3
SOP 4
SOP 4V
ČSN EN 12619
ČSN EN 13284-1
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 17340