🇨🇿 Detekta s.r.o. PL

ČIA 1582 • Brno - Maloměřice, Czech Republic • 15 methods

Environment

Detekta s.r.o. is a laboratory accredited by ČIA under number 1582 (Brno - Maloměřice, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: condensation method, absorption method, capacitive sensor, flame ionisation detection, gravimetric method.

At a glance

  • Accreditation number: ČIA 1582
  • Methods in scope: 15
  • Types of test objects: 1
  • Techniques used: 5
  • City: Brno - Maloměřice, Czech Republic
  • Valid until: 31-10-2027
Accreditation number
1582
Accreditation body
ČIA
Address
Franzova 63, 614 00 Brno - Maloměřice
City
Brno - Maloměřice, Czech Republic
Division
Laboratorium Pomiarów Emisji
Valid until
31-10-2027

What this laboratory tests (1)

Analytical techniques used (5)

Certificate information

Certificate date
31.10.2022

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of flow velocity and volume flow rate of gas in the duct
Regulated area: Tests
SOP 001, Část A (ČSN ISO 10780, ČSN EN ISO 16911-1)
2 Emissions Determination of gas moisture
Regulated area: Tests
condensation method, absorption method, capacitive sensor SOP 001, Část B (ČSN EN 14790)
3 Emissions Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers
Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO)
Regulated area: Tests
non-dispersive infrared spectroscopy SOP 002, Část A (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)
4 Emissions Determination of oxygen (O2) concentration by automated analysers
Regulated area: Tests
paramagnetic method SOP 002, Část B (ČSN EN 14789)
5 Emissions Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers
Regulated area: Tests
flame ionisation detection SOP 003 (ČSN EN 12619)
6 Emissions Determination of mass concentration of organic substances (VOC) by trapping on sorbent by calculation from measured values
Regulated area: Tests
SOP 004, odstavec 7, 8 (ČSN P CEN/TS 13649)
7 Emissions Determination of mass concentration of particulate pollutants by gravimetric method
Regulated area: Tests
gravimetric method SOP 005, odstavec 9, 10, 11 (ČSN EN 13284-1)
8 Emissions Determination of mass concentration of selected elements by calculation from measured values (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn)
Arsenic (As) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Mercury (Hg) Manganese (Mn) Nickel (Ni) Thallium (Tl) Selenium (Se) Tellurium (Te) Antimony (Sb) Tin (Sn) Lead (Pb) Vanadium (V) Zinc (Zn)
Regulated area: Tests
SOP 006, odstavec 9, 10 (ČSN EN 14385, ČSN EN 13211, US EPA 29)
9 Emissions Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH)
PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAH (polycyclic aromatic hydrocarbons)
Regulated area: Tests
SOP 007, odstavec 9, 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1)
10 Emissions Determination of mass concentration of gaseous inorganic chlorine compounds by calculation from measured values
Regulated area: Tests
SOP 010 (ČSN EN 1911)
11 Emissions Sampling of organic substances (VOC) by trapping on sorbent
Regulated area: Sampling
SOP 004, odstavec 5, 6 (ČSN P CEN/TS 13649)
12 Emissions Sampling of particulate pollutants (isokinetic sampling with automatic isokinetic control)
Regulated area: Sampling
SOP 005, odstavec 5, 7, 8 (ČSN EN 13284-1)
13 Emissions Sampling for determination of selected elements (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (isokinetic sampling with automatic isokinetic control and absorption into liquid)
Regulated area: Sampling
SOP 006, odstavec 5, 7, 8 (ČSN EN 14385, ČSN EN 13211, US EPA 29)
14 Emissions Sampling for determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) (isokinetic sampling with automatic isokinetic control, filter-condenser method)
Regulated area: Sampling
SOP 007, odstavec 5, 7, 8 (ČSN EN 1948-1, ČSN EN 1948-4+A1)
15 Emissions Sampling for determination of gaseous inorganic chlorine compounds by absorption into liquid
Regulated area: Sampling
SOP 010 (ČSN EN 1911)

Reference standards (30)

SOP 001, Část A
SOP 001, Část B
SOP 002, Část A
SOP 002, Část B
SOP 003
SOP 004, odstavec 5, 6
SOP 004, odstavec 7, 8
SOP 005, odstavec 5, 7, 8
SOP 005, odstavec 9, 10, 11
SOP 006, odstavec 5, 7, 8
SOP 006, odstavec 9, 10
SOP 007, odstavec 5, 7, 8
SOP 007, odstavec 9, 10
SOP 010
US EPA 29
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-4+A1
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 13649

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1582