🇨🇿 Detekta s.r.o. PL
Environment
Detekta s.r.o. is a laboratory accredited by ČIA under number 1582 (Brno - Maloměřice, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: condensation method, absorption method, capacitive sensor, flame ionisation detection, gravimetric method.
At a glance
- Accreditation number: ČIA 1582
- Methods in scope: 15
- Types of test objects: 1
- Techniques used: 5
- City: Brno - Maloměřice, Czech Republic
- Valid until: 31-10-2027
- Accreditation number
- 1582
- Accreditation body
- ČIA
- Address
- Franzova 63, 614 00 Brno - Maloměřice
- City
- Brno - Maloměřice, Czech Republic
- Division
- Laboratorium Pomiarów Emisji
- Valid until
- 31-10-2027
What this laboratory tests (1)
- Emissions — 15 methods
Analytical techniques used (5)
- condensation method, absorption method, capacitive sensor — 1 method
- flame ionisation detection — 1 method
- gravimetric method — 1 method
- non-dispersive infrared spectroscopy — 1 method
- paramagnetic method — 1 method
Certificate information
- Certificate date
- 31.10.2022
Accreditation scope — test methods (15)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of flow velocity and volume flow rate of gas in the duct Regulated area: Tests |
SOP 001, Část A (ČSN ISO 10780, ČSN EN ISO 16911-1) | ||
| 2 | Emissions | Determination of gas moisture Regulated area: Tests |
condensation method, absorption method, capacitive sensor | SOP 001, Část B (ČSN EN 14790) | |
| 3 | Emissions | Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO) Regulated area: Tests |
non-dispersive infrared spectroscopy | SOP 002, Část A (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058) | |
| 4 | Emissions | Determination of oxygen (O2) concentration by automated analysers Regulated area: Tests |
paramagnetic method | SOP 002, Část B (ČSN EN 14789) | |
| 5 | Emissions | Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers Regulated area: Tests |
flame ionisation detection | SOP 003 (ČSN EN 12619) | |
| 6 | Emissions | Determination of mass concentration of organic substances (VOC) by trapping on sorbent by calculation from measured values Regulated area: Tests |
SOP 004, odstavec 7, 8 (ČSN P CEN/TS 13649) | ||
| 7 | Emissions | Determination of mass concentration of particulate pollutants by gravimetric method Regulated area: Tests |
gravimetric method | SOP 005, odstavec 9, 10, 11 (ČSN EN 13284-1) | |
| 8 | Emissions | Determination of mass concentration of selected elements by calculation from measured values (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) Arsenic (As) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Mercury (Hg) Manganese (Mn) Nickel (Ni) Thallium (Tl) Selenium (Se) Tellurium (Te) Antimony (Sb) Tin (Sn) Lead (Pb) Vanadium (V) Zinc (Zn) Regulated area: Tests |
SOP 006, odstavec 9, 10 (ČSN EN 14385, ČSN EN 13211, US EPA 29) | ||
| 9 | Emissions | Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAH (polycyclic aromatic hydrocarbons) Regulated area: Tests |
SOP 007, odstavec 9, 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1) | ||
| 10 | Emissions | Determination of mass concentration of gaseous inorganic chlorine compounds by calculation from measured values Regulated area: Tests |
SOP 010 (ČSN EN 1911) | ||
| 11 | Emissions | Sampling of organic substances (VOC) by trapping on sorbent Regulated area: Sampling |
SOP 004, odstavec 5, 6 (ČSN P CEN/TS 13649) | ||
| 12 | Emissions | Sampling of particulate pollutants (isokinetic sampling with automatic isokinetic control) Regulated area: Sampling |
SOP 005, odstavec 5, 7, 8 (ČSN EN 13284-1) | ||
| 13 | Emissions | Sampling for determination of selected elements (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (isokinetic sampling with automatic isokinetic control and absorption into liquid) Regulated area: Sampling |
SOP 006, odstavec 5, 7, 8 (ČSN EN 14385, ČSN EN 13211, US EPA 29) | ||
| 14 | Emissions | Sampling for determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) (isokinetic sampling with automatic isokinetic control, filter-condenser method) Regulated area: Sampling |
SOP 007, odstavec 5, 7, 8 (ČSN EN 1948-1, ČSN EN 1948-4+A1) | ||
| 15 | Emissions | Sampling for determination of gaseous inorganic chlorine compounds by absorption into liquid Regulated area: Sampling |
SOP 010 (ČSN EN 1911) | ||
Reference standards (30)
SOP 001, Část A
SOP 001, Část B
SOP 002, Část A
SOP 002, Část B
SOP 003
SOP 004, odstavec 5, 6
SOP 004, odstavec 7, 8
SOP 005, odstavec 5, 7, 8
SOP 005, odstavec 9, 10, 11
SOP 006, odstavec 5, 7, 8
SOP 006, odstavec 9, 10
SOP 007, odstavec 5, 7, 8
SOP 007, odstavec 9, 10
SOP 010
US EPA 29
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-4+A1
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 13649