{"lab":{"_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","address":"Franzova 63, 614 00 Brno - Maloměřice","categories":["environment"],"city":"Brno - Maloměřice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":15,"name":"Detekta s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1582_515_2022_CS.pdf","1582_515_2022_EN.pdf"],"scope_summary":"Pomiary emisji substancji zanieczyszczających i pobieranie ich próbek ze stacjonarnych źródeł zanieczyszczania.","search_text":"detekta s.r.o. franzova 63, 614 00 brno - maloměřice 1582","status":"active","updated_at":"2026-03-08T14:52:13.577Z","valid_from":"","valid_until":"31-10-2027","website":"www.detekta.cz","location":{"type":"Point","coordinates":[16.6068,49.1951]},"map_coord":[49.218765,16.641352],"map_geo":"nominatim-street","certificate_date":"31.10.2022","certificate_no":"515/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary emisji substancji zanieczyszczających i pobieranie ich próbek ze stacjonarnych źródeł zanieczyszczania.","en":"Measurement of pollutant emissions and their sampling from stationary sources of pollution.","zh":"固定污染源污染物排放的测量及其采样。","cs":"Měření emisí znečišťujících látek a jejich vzorkování ze stacionárních zdrojů znečišťování."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Pomiarów Emisji","lab_division_cs":"Laboratoř měření emisí","lab_division_en":"Emission Measurement Laboratory","lab_division_zh":"排放测量实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"Emise","pl":"gaz odlotowy zawierający substancje zanieczyszczające, odprowadzany w sposób zorganizowany lub uchodzący do powietrza atmosferycznego ze źródeł zanieczyszczania powietrza","en":"waste gas containing pollutants that is discharged in a controlled manner or escapes into the outdoor atmosphere from sources of air pollution","zh":"从大气污染源以受控方式排放或逸散到室外大气中的含污染物废气","cs":"odpadní plyn s obsahem znečišťujících látek, který je odváděn řízeným způsobem nebo uniká do venkovní atmosféry ze zdrojů znečišťování ovzduší"},{"abbr":"SOP","pl":"standardowa procedura operacyjna","en":"standard operating procedure","zh":"标准操作程序","cs":"standardní operační postup"},{"abbr":"VOC","pl":"lotne związki organiczne","en":"volatile organic compounds","zh":"挥发性有机物","cs":"těkavé organické látky"},{"abbr":"TOC","pl":"suma lotnych związków organicznych wyrażonych jako całkowity węgiel organiczny","en":"sum of volatile organic compounds expressed as total organic carbon","zh":"以总有机碳表示的挥发性有机物总和","cs":"suma těkavých organických látek vyjádřených jako celkový organický uhlík"},{"abbr":"PCDD/PCDF","pl":"polichlorowane dibenzodioksyny i dibenzofurany","en":"polychlorinated dibenzodioxins and dibenzofurans","zh":"多氯二苯并二噁英和二苯并呋喃","cs":"polychlorované dibenzodioxiny a dibenzofurany"},{"abbr":"PCB","pl":"polichlorowane bifenyle","en":"polychlorinated biphenyls","zh":"多氯联苯","cs":"polychlorované bifenyly"},{"abbr":"PAH","pl":"wielopierścieniowe węglowodory aromatyczne","en":"polycyclic aromatic hydrocarbons","zh":"多环芳烃","cs":"polycyklické aromatické uhlovodíky"},{"abbr":"US EPA","pl":"Agencja Ochrony Środowiska, USA","en":"Environmental Protection Agency, USA","zh":"美国环境保护署","cs":"Agentura pro ochranu životního prostředí, USA"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"d51aa54cf4aae4ec932ea3dd6113ce9721cab59438b1d41102f70ecc92a07f7b","source_pdf_url":"https://www.cai.cz/OA/pdf/P515_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"5c01aeaf8e7fb016be5b36fd","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie prędkości przepływu i strumienia objętości gazu w przewodzie","methodology_en":"Determination of flow velocity and volume flow rate of gas in the duct","methodology_zh":"管道内气体流速和体积流量的测定","methodology_cs":"Stanovení rychlosti proudění a objemového toku plynu v potrubí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prędkości przepływu i strumienia objętości gazu w przewodzie","reference":"SOP 001, Část A (ČSN ISO 10780, ČSN EN ISO 16911-1)","norm_bases":["SOP 001, Část A","ČSN ISO 10780","ČSN EN ISO 16911-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie prędkości przepływu i strumienia objętości gazu w przewodzie Emise Stanovení rychlosti proudění a objemového toku plynu v potrubí SOP 001, Část A (ČSN ISO 10780, ČSN EN ISO 16911-1) Emisja Oznaczanie predkosci przeplywu i strumienia objetosci gazu w przewodzie Emise Stanoveni rychlosti proudeni a objemoveho toku plynu v potrubi SOP 001, Cast A (CSN ISO 10780, CSN EN ISO 16911-1)","search_en":"Emissions Determination of flow velocity and volume flow rate of gas in the duct SOP 001, Část A (ČSN ISO 10780, ČSN EN ISO 16911-1)","search_zh":"排放 管道内气体流速和体积流量的测定 SOP 001, Část A (ČSN ISO 10780, ČSN EN ISO 16911-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"242619788be21af0b9070459","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie wilgotności gazu","methodology_en":"Determination of gas moisture","methodology_zh":"气体湿度的测定","methodology_cs":"Stanovení vlhkosti plynu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda kondensacyjna, metoda absorpcyjna, czujnik pojemnościowy","technique_en":"condensation method, absorption method, capacitive sensor","technique_zh":"冷凝法、吸收法、电容传感器","technique_cs":"metoda kondenzační, metoda absorpční, kapacitní čidlo","techniques":["metoda kondensacyjna, metoda absorpcyjna, czujnik pojemnościowy"],"techniques_en":["condensation method, absorption method, capacitive sensor"],"techniques_zh":["冷凝法、吸收法、电容传感器"],"techniques_cs":["metoda kondenzační, metoda absorpční, kapacitní čidlo"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności gazu\nmetoda kondensacyjna, metoda absorpcyjna, czujnik pojemnościowy","reference":"SOP 001, Část B (ČSN EN 14790)","norm_bases":["SOP 001, Část B","ČSN EN 14790"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie wilgotności gazu metoda kondensacyjna, metoda absorpcyjna, czujnik pojemnościowy Emise Stanovení vlhkosti plynu metoda kondenzační, metoda absorpční, kapacitní čidlo SOP 001, Část B (ČSN EN 14790) Emisja Oznaczanie wilgotnosci gazu metoda kondensacyjna, metoda absorpcyjna, czujnik pojemnosciowy Emise Stanoveni vlhkosti plynu metoda kondenzacni, metoda absorpcni, kapacitni cidlo SOP 001, Cast B (CSN EN 14790)","search_en":"Emissions Determination of gas moisture condensation method, absorption method, capacitive sensor SOP 001, Část B (ČSN EN 14790)","search_zh":"排放 气体湿度的测定 冷凝法、吸收法、电容传感器 SOP 001, Část B (ČSN EN 14790)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"06f1590ad2fdff7e129c4b4a","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi","methodology_en":"Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers","methodology_zh":"自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOx, CO) automatizovanými analyzátory","parameters":[{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki azotu (NOx)","range":""},{"name":"Tlenek węgla (CO)","range":""}],"parameters_en":[{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Nitrogen oxides (NOx)","range":""},{"name":"Carbon monoxide (CO)","range":""}],"parameters_zh":[{"name":"二氧化硫（SO2）","range":""},{"name":"氮氧化物（NOx）","range":""},{"name":"一氧化碳（CO）","range":""}],"parameters_cs":[{"name":"SO2","range":""},{"name":"NOx","range":""},{"name":"CO","range":""}],"technique":"niedyspersyjna spektroskopia w podczerwieni","technique_en":"non-dispersive infrared spectroscopy","technique_zh":"非分散红外光谱法","technique_cs":"nedisperzní infračervená spektroskopie","techniques":["niedyspersyjna spektroskopia w podczerwieni"],"techniques_en":["non-dispersive infrared spectroscopy"],"techniques_zh":["非分散红外光谱法"],"techniques_cs":["nedisperzní infračervená spektroskopie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi\nZakres:\nDitlenek siarki (SO2)\nTlenki azotu (NOx)\nTlenek węgla (CO)\nniedyspersyjna spektroskopia w podczerwieni","reference":"SOP 002, Část A (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","norm_bases":["SOP 002, Část A","ČSN ISO 7935","ČSN ISO 10849","ČSN EN 15058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi niedyspersyjna spektroskopia w podczerwieni Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek węgla (CO)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOx, CO) automatizovanými analyzátory nedisperzní infračervená spektroskopie SO2  NOx  CO  SOP 002, Část A (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych (SO2, NOx, CO) analizatorami automatycznymi niedyspersyjna spektroskopia w podczerwieni Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek wegla (CO)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek (SO2, NOx, CO) automatizovanymi analyzatory nedisperzni infracervena spektroskopie SO2  NOx  CO  SOP 002, Cast A (CSN ISO 7935, CSN ISO 10849, CSN EN 15058)","search_en":"Emissions Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers non-dispersive infrared spectroscopy Sulphur dioxide (SO2)  Nitrogen oxides (NOx)  Carbon monoxide (CO)  SOP 002, Část A (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","search_zh":"排放 自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度 非分散红外光谱法 二氧化硫（SO2）  氮氧化物（NOx）  一氧化碳（CO）  SOP 002, Část A (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91ba959cf025c0676b545055","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia tlenu (O2) analizatorami automatycznymi","methodology_en":"Determination of oxygen (O2) concentration by automated analysers","methodology_zh":"自动分析仪测定氧（O2）浓度","methodology_cs":"Stanovení koncentrace kyslíku (O2) automatizovanými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda paramagnetyczna","technique_en":"paramagnetic method","technique_zh":"顺磁法","technique_cs":"paramagnetická metoda","techniques":["metoda paramagnetyczna"],"techniques_en":["paramagnetic method"],"techniques_zh":["顺磁法"],"techniques_cs":["paramagnetická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia tlenu (O2) analizatorami automatycznymi\nmetoda paramagnetyczna","reference":"SOP 002, Část B (ČSN EN 14789)","norm_bases":["SOP 002, Část B","ČSN EN 14789"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia tlenu (O2) analizatorami automatycznymi metoda paramagnetyczna Emise Stanovení koncentrace kyslíku (O2) automatizovanými analyzátory paramagnetická metoda SOP 002, Část B (ČSN EN 14789) Emisja Oznaczanie stezenia tlenu (O2) analizatorami automatycznymi metoda paramagnetyczna Emise Stanoveni koncentrace kysliku (O2) automatizovanymi analyzatory paramagneticka metoda SOP 002, Cast B (CSN EN 14789)","search_en":"Emissions Determination of oxygen (O2) concentration by automated analysers paramagnetic method SOP 002, Část B (ČSN EN 14789)","search_zh":"排放 自动分析仪测定氧（O2）浓度 顺磁法 SOP 002, Část B (ČSN EN 14789)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dd644d388d92bcd83f3b9e79","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi","methodology_en":"Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers","methodology_zh":"自动分析仪测定以总有机碳（TOC）表示的有机物质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"detekcja płomieniowo-jonizacyjna","technique_en":"flame ionisation detection","technique_zh":"火焰离子化检测","technique_cs":"plamenoionizační detekce","techniques":["detekcja płomieniowo-jonizacyjna"],"techniques_en":["flame ionisation detection"],"techniques_zh":["火焰离子化检测"],"techniques_cs":["plamenoionizační detekce"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi\ndetekcja płomieniowo-jonizacyjna","reference":"SOP 003 (ČSN EN 12619)","norm_bases":["SOP 003","ČSN EN 12619"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi detekcja płomieniowo-jonizacyjna Emise Stanovení hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory plamenoionizační detekce SOP 003 (ČSN EN 12619) Emisja Oznaczanie stezenia masowego substancji organicznych wyrazonych jako calkowity wegiel organiczny (TOC) analizatorami automatycznymi detekcja plomieniowo-jonizacyjna Emise Stanoveni hmotnostni koncentrace organickych latek vyjadrenych jako celkovy organicky uhlik (TOC) automatizovanymi analyzatory plamenoionizacni detekce SOP 003 (CSN EN 12619)","search_en":"Emissions Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers flame ionisation detection SOP 003 (ČSN EN 12619)","search_zh":"排放 自动分析仪测定以总有机碳（TOC）表示的有机物质量浓度 火焰离子化检测 SOP 003 (ČSN EN 12619)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"280c0b6b4c03be252c52fdb2","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"6","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego substancji organicznych (VOC) przez wychwyt na sorbencie obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of organic substances (VOC) by trapping on sorbent by calculation from measured values","methodology_zh":"吸附剂捕集并由测量值计算测定有机物（VOC）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace organických látek (VOC) záchytem na sorbent výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego substancji organicznych (VOC) przez wychwyt na sorbencie obliczeniowo z wartości zmierzonych","reference":"SOP 004, odstavec 7, 8 (ČSN P CEN/TS 13649)","norm_bases":["SOP 004, odstavec 7, 8","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"analizę pobranej próbki wykonują zewnętrzni dostawcy w akredytowanym laboratorium badawczym","note_en":"analysis of the collected sample is performed by external suppliers in an accredited testing laboratory","note_zh":"所采样品的分析由外部供应方在经认可的检测实验室进行","note_cs":"analýza odebraného vzorku je prováděna externími dodavateli v akreditované zkušební laboratoři","search_text":"Emisja Oznaczanie stężenia masowego substancji organicznych (VOC) przez wychwyt na sorbencie obliczeniowo z wartości zmierzonych Emise Stanovení hmotnostní koncentrace organických látek (VOC) záchytem na sorbent výpočtem z naměřených hodnot SOP 004, odstavec 7, 8 (ČSN P CEN/TS 13649) Emisja Oznaczanie stezenia masowego substancji organicznych (VOC) przez wychwyt na sorbencie obliczeniowo z wartosci zmierzonych Emise Stanoveni hmotnostni koncentrace organickych latek (VOC) zachytem na sorbent vypoctem z namerenych hodnot SOP 004, odstavec 7, 8 (CSN P CEN/TS 13649)","search_en":"Emissions Determination of mass concentration of organic substances (VOC) by trapping on sorbent by calculation from measured values SOP 004, odstavec 7, 8 (ČSN P CEN/TS 13649)","search_zh":"排放 吸附剂捕集并由测量值计算测定有机物（VOC）的质量浓度 SOP 004, odstavec 7, 8 (ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"229aedbcbb62f87179c69e34","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"7","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną","methodology_en":"Determination of mass concentration of particulate pollutants by gravimetric method","methodology_zh":"重量法测定颗粒污染物的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetrickou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetric method","technique_zh":"重量法","technique_cs":"gravimetrickou metodou","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrickou metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną\nmetoda grawimetryczna","reference":"SOP 005, odstavec 9, 10, 11 (ČSN EN 13284-1)","norm_bases":["SOP 005, odstavec 9, 10, 11","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną metoda grawimetryczna Emise Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetrickou metodou gravimetrickou metodou SOP 005, odstavec 9, 10, 11 (ČSN EN 13284-1) Emisja Oznaczanie stezenia masowego pylowych substancji zanieczyszczajacych metoda grawimetryczna metoda grawimetryczna Emise Stanoveni hmotnostni koncentrace tuhych znecistujicich latek gravimetrickou metodou gravimetrickou metodou SOP 005, odstavec 9, 10, 11 (CSN EN 13284-1)","search_en":"Emissions Determination of mass concentration of particulate pollutants by gravimetric method gravimetric method SOP 005, odstavec 9, 10, 11 (ČSN EN 13284-1)","search_zh":"排放 重量法测定颗粒污染物的质量浓度 重量法 SOP 005, odstavec 9, 10, 11 (ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4e9e94d93e27941451c1676c","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"8","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego wybranych pierwiastków obliczeniowo z wartości zmierzonych (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn)","methodology_en":"Determination of mass concentration of selected elements by calculation from measured values (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn)","methodology_zh":"由测量值计算测定所选元素（As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Tl、Se、Te、Sb、Sn、Pb、V、Zn）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace vybraných prvků výpočtem z naměřených hodnot (As, Be, Cd, Co, Cr, Cu, Hg Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn)","parameters":[{"name":"Arsen (As)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Rtęć (Hg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Selen (Se)","range":""},{"name":"Tellur (Te)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Mercury (Hg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tellurium (Te)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"铍（Be）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"汞（Hg）","range":""},{"name":"锰（Mn）","range":""},{"name":"镍（Ni）","range":""},{"name":"铊（Tl）","range":""},{"name":"硒（Se）","range":""},{"name":"碲（Te）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Be","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Hg","range":""},{"name":"Mn","range":""},{"name":"Ni","range":""},{"name":"Tl","range":""},{"name":"Se","range":""},{"name":"Te","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego wybranych pierwiastków obliczeniowo z wartości zmierzonych (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn)\nZakres:\nArsen (As)\nBeryl (Be)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nRtęć (Hg)\nMangan (Mn)\nNikiel (Ni)\nTal (Tl)\nSelen (Se)\nTellur (Te)\nAntymon (Sb)\nCyna (Sn)\nOłów (Pb)\nWanad (V)\nCynk (Zn)","reference":"SOP 006, odstavec 9, 10 (ČSN EN 14385, ČSN EN 13211, US EPA 29)","norm_bases":["SOP 006, odstavec 9, 10","ČSN EN 14385","ČSN EN 13211","US EPA 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"analizę pobranej próbki wykonują zewnętrzni dostawcy w akredytowanym laboratorium badawczym","note_en":"analysis of the collected sample is performed by external suppliers in an accredited testing laboratory","note_zh":"所采样品的分析由外部供应方在经认可的检测实验室进行","note_cs":"analýza odebraného vzorku je prováděna externími dodavateli v akreditované zkušební laboratoři","search_text":"Emisja Oznaczanie stężenia masowego wybranych pierwiastków obliczeniowo z wartości zmierzonych (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) Arsen (As)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Rtęć (Hg)  Mangan (Mn)  Nikiel (Ni)  Tal (Tl)  Selen (Se)  Tellur (Te)  Antymon (Sb)  Cyna (Sn)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  Emise Stanovení hmotnostní koncentrace vybraných prvků výpočtem z naměřených hodnot (As, Be, Cd, Co, Cr, Cu, Hg Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) As  Be  Cd  Co  Cr  Cu  Hg  Mn  Ni  Tl  Se  Te  Sb  Sn  Pb  V  Zn  SOP 006, odstavec 9, 10 (ČSN EN 14385, ČSN EN 13211, US EPA 29) Emisja Oznaczanie stezenia masowego wybranych pierwiastkow obliczeniowo z wartosci zmierzonych (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) Arsen (As)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Rtec (Hg)  Mangan (Mn)  Nikiel (Ni)  Tal (Tl)  Selen (Se)  Tellur (Te)  Antymon (Sb)  Cyna (Sn)  Olow (Pb)  Wanad (V)  Cynk (Zn)  Emise Stanoveni hmotnostni koncentrace vybranych prvku vypoctem z namerenych hodnot (As, Be, Cd, Co, Cr, Cu, Hg Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) As  Be  Cd  Co  Cr  Cu  Hg  Mn  Ni  Tl  Se  Te  Sb  Sn  Pb  V  Zn  SOP 006, odstavec 9, 10 (CSN EN 14385, CSN EN 13211, US EPA 29)","search_en":"Emissions Determination of mass concentration of selected elements by calculation from measured values (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) Arsenic (As)  Beryllium (Be)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Mercury (Hg)  Manganese (Mn)  Nickel (Ni)  Thallium (Tl)  Selenium (Se)  Tellurium (Te)  Antimony (Sb)  Tin (Sn)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  SOP 006, odstavec 9, 10 (ČSN EN 14385, ČSN EN 13211, US EPA 29)","search_zh":"排放 由测量值计算测定所选元素（As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Tl、Se、Te、Sb、Sn、Pb、V、Zn）的质量浓度 砷（As）  铍（Be）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  汞（Hg）  锰（Mn）  镍（Ni）  铊（Tl）  硒（Se）  碲（Te）  锑（Sb）  锡（Sn）  铅（Pb）  钒（V）  锌（Zn）  SOP 006, odstavec 9, 10 (ČSN EN 14385, ČSN EN 13211, US EPA 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3b0c0e2883dcba27ebf1b0e0","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"9","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych obliczeniowo z wartości zmierzonych (PCDD/PCDF, PCB, PAH)","methodology_en":"Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH)","methodology_zh":"由测量值计算测定持久性有机污染物（PCDD/PCDF、PCB、PAH）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace persistentních organických látek výpočtem z naměřených hodnot (PCDD/PCDF, PCB, PAH)","parameters":[{"name":"PCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)","range":""},{"name":"PCB (polichlorowane bifenyle)","range":""},{"name":"PAH (wielopierścieniowe węglowodory aromatyczne)","range":""}],"parameters_en":[{"name":"PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans)","range":""},{"name":"PCB (polychlorinated biphenyls)","range":""},{"name":"PAH (polycyclic aromatic hydrocarbons)","range":""}],"parameters_zh":[{"name":"PCDD/PCDF（多氯二苯并二噁英和二苯并呋喃）","range":""},{"name":"PCB（多氯联苯）","range":""},{"name":"PAH（多环芳烃）","range":""}],"parameters_cs":[{"name":"PCDD/PCDF","range":""},{"name":"PCB","range":""},{"name":"PAH","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych obliczeniowo z wartości zmierzonych (PCDD/PCDF, PCB, PAH)\nZakres:\nPCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)\nPCB (polichlorowane bifenyle)\nPAH (wielopierścieniowe węglowodory aromatyczne)","reference":"SOP 007, odstavec 9, 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1)","norm_bases":["SOP 007, odstavec 9, 10","ČSN EN 1948-1","ČSN EN 1948-4+A1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"analizę pobranej próbki wykonują zewnętrzni dostawcy w akredytowanym laboratorium badawczym","note_en":"analysis of the collected sample is performed by external suppliers in an accredited testing laboratory","note_zh":"所采样品的分析由外部供应方在经认可的检测实验室进行","note_cs":"analýza odebraného vzorku je prováděna externími dodavateli v akreditované zkušební laboratoři","search_text":"Emisja Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych obliczeniowo z wartości zmierzonych (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)  PCB (polichlorowane bifenyle)  PAH (wielopierścieniowe węglowodory aromatyczne)  Emise Stanovení hmotnostní koncentrace persistentních organických látek výpočtem z naměřených hodnot (PCDD/PCDF, PCB, PAH) PCDD/PCDF  PCB  PAH  SOP 007, odstavec 9, 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1) Emisja Oznaczanie stezenia masowego trwalych zanieczyszczen organicznych obliczeniowo z wartosci zmierzonych (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)  PCB (polichlorowane bifenyle)  PAH (wielopierscieniowe weglowodory aromatyczne)  Emise Stanoveni hmotnostni koncentrace persistentnich organickych latek vypoctem z namerenych hodnot (PCDD/PCDF, PCB, PAH) PCDD/PCDF  PCB  PAH  SOP 007, odstavec 9, 10 (CSN EN 1948-1, CSN EN 1948-4+A1)","search_en":"Emissions Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans)  PCB (polychlorinated biphenyls)  PAH (polycyclic aromatic hydrocarbons)  SOP 007, odstavec 9, 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1)","search_zh":"排放 由测量值计算测定持久性有机污染物（PCDD/PCDF、PCB、PAH）的质量浓度 PCDD/PCDF（多氯二苯并二噁英和二苯并呋喃）  PCB（多氯联苯）  PAH（多环芳烃）  SOP 007, odstavec 9, 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"396a54a461f47f37fa7e282b","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"10","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych nieorganicznych związków chloru obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of gaseous inorganic chlorine compounds by calculation from measured values","methodology_zh":"由测量值计算测定气态无机氯化合物的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných anorganických sloučenin chlóru výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych nieorganicznych związków chloru obliczeniowo z wartości zmierzonych","reference":"SOP 010 (ČSN EN 1911)","norm_bases":["SOP 010","ČSN EN 1911"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"analizę pobranej próbki wykonują zewnętrzni dostawcy w akredytowanym laboratorium badawczym","note_en":"analysis of the collected sample is performed by external suppliers in an accredited testing laboratory","note_zh":"所采样品的分析由外部供应方在经认可的检测实验室进行","note_cs":"analýza odebraného vzorku je prováděna externími dodavateli v akreditované zkušební laboratoři","search_text":"Emisja Oznaczanie stężenia masowego gazowych nieorganicznych związków chloru obliczeniowo z wartości zmierzonych Emise Stanovení hmotnostní koncentrace plynných anorganických sloučenin chlóru výpočtem z naměřených hodnot SOP 010 (ČSN EN 1911) Emisja Oznaczanie stezenia masowego gazowych nieorganicznych zwiazkow chloru obliczeniowo z wartosci zmierzonych Emise Stanoveni hmotnostni koncentrace plynnych anorganickych sloucenin chloru vypoctem z namerenych hodnot SOP 010 (CSN EN 1911)","search_en":"Emissions Determination of mass concentration of gaseous inorganic chlorine compounds by calculation from measured values SOP 010 (ČSN EN 1911)","search_zh":"排放 由测量值计算测定气态无机氯化合物的质量浓度 SOP 010 (ČSN EN 1911)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1664691ce2ab900efbac6ae4","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek substancji organicznych (VOC) przez wychwyt na sorbencie","methodology_en":"Sampling of organic substances (VOC) by trapping on sorbent","methodology_zh":"吸附剂捕集法采集有机物（VOC）样品","methodology_cs":"Odběr vzorku organických látek (VOC) záchytem na sorbent","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek substancji organicznych (VOC) przez wychwyt na sorbencie","reference":"SOP 004, odstavec 5, 6 (ČSN P CEN/TS 13649)","norm_bases":["SOP 004, odstavec 5, 6","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek substancji organicznych (VOC) przez wychwyt na sorbencie Emise Odběr vzorku organických látek (VOC) záchytem na sorbent SOP 004, odstavec 5, 6 (ČSN P CEN/TS 13649) Emisja Pobieranie probek substancji organicznych (VOC) przez wychwyt na sorbencie Emise Odber vzorku organickych latek (VOC) zachytem na sorbent SOP 004, odstavec 5, 6 (CSN P CEN/TS 13649)","search_en":"Emissions Sampling of organic substances (VOC) by trapping on sorbent SOP 004, odstavec 5, 6 (ČSN P CEN/TS 13649)","search_zh":"排放 吸附剂捕集法采集有机物（VOC）样品 SOP 004, odstavec 5, 6 (ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6d4a8b0aea95c5a2c2fca240","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek pyłowych substancji zanieczyszczających (pobór izokinetyczny z automatyczną regulacją izokinetyki)","methodology_en":"Sampling of particulate pollutants (isokinetic sampling with automatic isokinetic control)","methodology_zh":"颗粒污染物采样（自动等速控制的等速采样）","methodology_cs":"Odběr vzorku tuhých znečišťujících látek (izokinetický odběr s automatickým řízením izokinetiky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek pyłowych substancji zanieczyszczających (pobór izokinetyczny z automatyczną regulacją izokinetyki)","reference":"SOP 005, odstavec 5, 7, 8 (ČSN EN 13284-1)","norm_bases":["SOP 005, odstavec 5, 7, 8","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek pyłowych substancji zanieczyszczających (pobór izokinetyczny z automatyczną regulacją izokinetyki) Emise Odběr vzorku tuhých znečišťujících látek (izokinetický odběr s automatickým řízením izokinetiky) SOP 005, odstavec 5, 7, 8 (ČSN EN 13284-1) Emisja Pobieranie probek pylowych substancji zanieczyszczajacych (pobor izokinetyczny z automatyczna regulacja izokinetyki) Emise Odber vzorku tuhych znecistujicich latek (izokineticky odber s automatickym rizenim izokinetiky) SOP 005, odstavec 5, 7, 8 (CSN EN 13284-1)","search_en":"Emissions Sampling of particulate pollutants (isokinetic sampling with automatic isokinetic control) SOP 005, odstavec 5, 7, 8 (ČSN EN 13284-1)","search_zh":"排放 颗粒污染物采样（自动等速控制的等速采样） SOP 005, odstavec 5, 7, 8 (ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61b49f23cf5abb0cedffd6f7","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek do oznaczania wybranych pierwiastków (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (pobór izokinetyczny z automatyczną regulacją izokinetyki i absorpcja w cieczy)","methodology_en":"Sampling for determination of selected elements (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (isokinetic sampling with automatic isokinetic control and absorption into liquid)","methodology_zh":"所选元素（As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Tl、Se、Te、Sb、Sn、Pb、V、Zn）测定用采样（自动等速控制的等速采样和液体吸收）","methodology_cs":"Odběr vzorku pro stanovení vybraných prvků (As, Be, Cd, Co, Cr, Cu, Hg Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (izokinetický odběr s automatickým řízením izokinetiky a absorbce do kapaliny)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek do oznaczania wybranych pierwiastków (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (pobór izokinetyczny z automatyczną regulacją izokinetyki i absorpcja w cieczy)","reference":"SOP 006, odstavec 5, 7, 8 (ČSN EN 14385, ČSN EN 13211, US EPA 29)","norm_bases":["SOP 006, odstavec 5, 7, 8","ČSN EN 14385","ČSN EN 13211","US EPA 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek do oznaczania wybranych pierwiastków (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (pobór izokinetyczny z automatyczną regulacją izokinetyki i absorpcja w cieczy) Emise Odběr vzorku pro stanovení vybraných prvků (As, Be, Cd, Co, Cr, Cu, Hg Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (izokinetický odběr s automatickým řízením izokinetiky a absorbce do kapaliny) SOP 006, odstavec 5, 7, 8 (ČSN EN 14385, ČSN EN 13211, US EPA 29) Emisja Pobieranie probek do oznaczania wybranych pierwiastkow (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (pobor izokinetyczny z automatyczna regulacja izokinetyki i absorpcja w cieczy) Emise Odber vzorku pro stanoveni vybranych prvku (As, Be, Cd, Co, Cr, Cu, Hg Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (izokineticky odber s automatickym rizenim izokinetiky a absorbce do kapaliny) SOP 006, odstavec 5, 7, 8 (CSN EN 14385, CSN EN 13211, US EPA 29)","search_en":"Emissions Sampling for determination of selected elements (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Tl, Se, Te, Sb, Sn, Pb, V, Zn) (isokinetic sampling with automatic isokinetic control and absorption into liquid) SOP 006, odstavec 5, 7, 8 (ČSN EN 14385, ČSN EN 13211, US EPA 29)","search_zh":"排放 所选元素（As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Tl、Se、Te、Sb、Sn、Pb、V、Zn）测定用采样（自动等速控制的等速采样和液体吸收） SOP 006, odstavec 5, 7, 8 (ČSN EN 14385, ČSN EN 13211, US EPA 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f6c90b6a06275770e38664f","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek do oznaczania trwałych zanieczyszczeń organicznych (PCDD/PCDF, PCB, PAH) (pobór izokinetyczny z automatyczną regulacją izokinetyki, metoda filtracyjno-kondensacyjna)","methodology_en":"Sampling for determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) (isokinetic sampling with automatic isokinetic control, filter-condenser method)","methodology_zh":"持久性有机污染物（PCDD/PCDF、PCB、PAH）测定用采样（自动等速控制的等速采样，过滤冷凝法）","methodology_cs":"Odběr vzorku pro stanovení persistentních organických látek (PCDD/PCDF, PCB, PAH) (izokinetický odběr s automatickým řízením izokinetiky, metoda filtrační-kondenzační)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek do oznaczania trwałych zanieczyszczeń organicznych (PCDD/PCDF, PCB, PAH) (pobór izokinetyczny z automatyczną regulacją izokinetyki, metoda filtracyjno-kondensacyjna)","reference":"SOP 007, odstavec 5, 7, 8 (ČSN EN 1948-1, ČSN EN 1948-4+A1)","norm_bases":["SOP 007, odstavec 5, 7, 8","ČSN EN 1948-1","ČSN EN 1948-4+A1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek do oznaczania trwałych zanieczyszczeń organicznych (PCDD/PCDF, PCB, PAH) (pobór izokinetyczny z automatyczną regulacją izokinetyki, metoda filtracyjno-kondensacyjna) Emise Odběr vzorku pro stanovení persistentních organických látek (PCDD/PCDF, PCB, PAH) (izokinetický odběr s automatickým řízením izokinetiky, metoda filtrační-kondenzační) SOP 007, odstavec 5, 7, 8 (ČSN EN 1948-1, ČSN EN 1948-4+A1) Emisja Pobieranie probek do oznaczania trwalych zanieczyszczen organicznych (PCDD/PCDF, PCB, PAH) (pobor izokinetyczny z automatyczna regulacja izokinetyki, metoda filtracyjno-kondensacyjna) Emise Odber vzorku pro stanoveni persistentnich organickych latek (PCDD/PCDF, PCB, PAH) (izokineticky odber s automatickym rizenim izokinetiky, metoda filtracni-kondenzacni) SOP 007, odstavec 5, 7, 8 (CSN EN 1948-1, CSN EN 1948-4+A1)","search_en":"Emissions Sampling for determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) (isokinetic sampling with automatic isokinetic control, filter-condenser method) SOP 007, odstavec 5, 7, 8 (ČSN EN 1948-1, ČSN EN 1948-4+A1)","search_zh":"排放 持久性有机污染物（PCDD/PCDF、PCB、PAH）测定用采样（自动等速控制的等速采样，过滤冷凝法） SOP 007, odstavec 5, 7, 8 (ČSN EN 1948-1, ČSN EN 1948-4+A1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"27887951b8ad5a43caee8622","lab_id":"69ad52a4de79e566650fd4ac","country":"CZ","accr_number":"1582","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek do oznaczania gazowych nieorganicznych związków chloru przez absorpcję w cieczy","methodology_en":"Sampling for determination of gaseous inorganic chlorine compounds by absorption into liquid","methodology_zh":"液体吸收法采集气态无机氯化合物测定用样品","methodology_cs":"Odběr vzorku pro stanovení plynných anorganických sloučenin chloru absorpcí do kapaliny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek do oznaczania gazowych nieorganicznych związków chloru przez absorpcję w cieczy","reference":"SOP 010 (ČSN EN 1911)","norm_bases":["SOP 010","ČSN EN 1911"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek do oznaczania gazowych nieorganicznych związków chloru przez absorpcję w cieczy Emise Odběr vzorku pro stanovení plynných anorganických sloučenin chloru absorpcí do kapaliny SOP 010 (ČSN EN 1911) Emisja Pobieranie probek do oznaczania gazowych nieorganicznych zwiazkow chloru przez absorpcje w cieczy Emise Odber vzorku pro stanoveni plynnych anorganickych sloucenin chloru absorpci do kapaliny SOP 010 (CSN EN 1911)","search_en":"Emissions Sampling for determination of gaseous inorganic chlorine compounds by absorption into liquid SOP 010 (ČSN EN 1911)","search_zh":"排放 液体吸收法采集气态无机氯化合物测定用样品 SOP 010 (ČSN EN 1911)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}