🇨🇿 Ing. Pavel Študent PL

ČIA 1576 • Trojanovice, Czech Republic • 7 methods

Environment

Ing. Pavel Študent is a laboratory accredited by ČIA under number 1576 (Trojanovice, Czech Republic). Its accreditation scope covers 7 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: capacitive sensor, flame ionisation detector (FID), gravimetry.

At a glance

  • Accreditation number: ČIA 1576
  • Methods in scope: 7
  • Types of test objects: 1
  • Techniques used: 4
  • City: Trojanovice, Czech Republic
  • Valid until: 05-12-2027
Accreditation number
1576
Accreditation body
ČIA
Address
Trojanovice 302, 744 01 Trojanovice
City
Trojanovice, Czech Republic
Division
inPAS – Autoryzowane pomiary emisji
Valid until
05-12-2027

What this laboratory tests (1)

Analytical techniques used (4)

Certificate information

Certificate date
05.12.2022

Accreditation scope — test methods (7)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of flow velocity and volume flow rate
Regulated area: Tests
ČSN ISO 10780, čl. 6-10
2 Emissions Determination of gas moisture
Regulated area: Tests
capacitive sensor SOP 007 (návod firmy E+E Elektronik)
3 Emissions Determination of oxygen by automated analysers using the paramagnetic method
Regulated area: Tests
SOP 009 (ČSN EN 14789)
4 Emissions Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers using the NDIR method
Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO)
Regulated area: Tests
SOP 010 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)
5 Emissions Determination of mass concentration of particulate pollutants
Regulated area: Tests
gravimetry SOP 006 (ČSN ISO 9096:1998, ČSN EN 13284-1)
6 Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analyser
Regulated area: Tests
flame ionisation detector (FID) SOP 008 (ČSN EN 12619, ČSN EN 13526:2002)
7 Emissions Sampling of particulate pollutants
Regulated area: Sampling
manual and isokinetic sampling with automatic isokinetic control SOP 002 (ČSN ISO 9096:1998, ČSN EN 13284-1)

Reference standards (16)

SOP 002
SOP 006
SOP 007
SOP 008
SOP 009
SOP 010
návod firmy E+E Elektronik
ČSN EN 12619
ČSN EN 13284-1
ČSN EN 13526:2002
ČSN EN 14789
ČSN EN 15058
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN ISO 9096:1998

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1576