{"lab":{"_id":"69ad52a4de79e566650fd4a8","accr_number":"1576","country":"CZ","accr_body":"ČIA","address":"Trojanovice 302, 744 01 Trojanovice","categories":["environment"],"city":"Trojanovice","imported_at":"2026-03-08T10:42:44.590Z","methods_count":7,"name":"Ing. Pavel Študent","parse_status":"parsed","parse_version":5,"pdf_files":["1576_584_2022_CS.pdf","1576_584_2022_EN.pdf"],"scope_summary":"Pomiary emisji substancji zanieczyszczających i towarzyszących wielkości aerodynamicznych ze źródeł stacjonarnych.","search_text":"ing. pavel študent trojanovice 302, 744 01 trojanovice 1576","status":"active","updated_at":"2026-03-08T14:52:13.571Z","valid_from":"","valid_until":"05-12-2027","website":"www.inpas.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.inpas.cz","map_coord":[49.520395,18.238003],"map_geo":"nominatim-city","certificate_date":"05.12.2022","certificate_no":"584/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary emisji substancji zanieczyszczających i towarzyszących wielkości aerodynamicznych ze źródeł stacjonarnych.","en":"Measurement of emissions of pollutants and associated air-handling quantities from stationary sources.","zh":"固定源污染物排放及相关通风参数的测量。","cs":"Měření emisí znečišťujících látek a doprovodných vzduchotechnických veličin ze stacionárních zdrojů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"inPAS – Autoryzowane pomiary emisji","lab_division_cs":"inPAS - Autorizované měření emisí","lab_division_en":"inPAS - Authorised Emission Measurement","lab_division_zh":"inPAS – 授权排放测量","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"Emise","pl":"gaz odlotowy zawierający substancje zanieczyszczające, odprowadzany lub uchodzący do powietrza atmosferycznego ze źródeł zanieczyszczania powietrza","en":"waste gas containing pollutants that is discharged or escapes into the outdoor atmosphere from sources of air pollution","zh":"从大气污染源排放或逸散到室外大气中的含污染物废气","cs":"odpadní plyn s obsahem znečišťujících látek, který je odváděn nebo uniká do venkovní atmosféry ze zdrojů znečišťování ovzduší"},{"abbr":"SOP","pl":"standardowa procedura operacyjna","en":"standard operating procedure","zh":"标准操作程序","cs":"standardní operační postup"},{"abbr":"NDIR","pl":"niedyspersyjna spektrometria w podczerwieni","en":"non-dispersive infrared spectrometry","zh":"非分散红外光谱法","cs":"nedisperzní infračervená spektrometrie"},{"abbr":"FID","pl":"detekcja płomieniowo-jonizacyjna","en":"flame ionisation detection","zh":"火焰离子化检测","cs":"plamenoionizační detekce"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"c6ae95d6b921fe5767210493d1858b58657a666fc26f75766e62f85f663a575a","source_pdf_url":"https://www.cai.cz/OA/pdf/P584_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"f57af808caf81d8fc520425c","lab_id":"69ad52a4de79e566650fd4a8","country":"CZ","accr_number":"1576","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie prędkości przepływu i strumienia objętości","methodology_en":"Determination of flow velocity and volume flow rate","methodology_zh":"流速和体积流量的测定","methodology_cs":"Stanovení rychlosti proudění a objemového toku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prędkości przepływu i strumienia objętości","reference":"ČSN ISO 10780, čl. 6-10","norm_bases":["ČSN ISO 10780"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie prędkości przepływu i strumienia objętości Emise Stanovení rychlosti proudění a objemového toku ČSN ISO 10780, čl. 6-10 Emisja Oznaczanie predkosci przeplywu i strumienia objetosci Emise Stanoveni rychlosti proudeni a objemoveho toku CSN ISO 10780, cl. 6-10","search_en":"Emissions Determination of flow velocity and volume flow rate ČSN ISO 10780, čl. 6-10","search_zh":"排放 流速和体积流量的测定 ČSN ISO 10780, čl. 6-10","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b0c2c91655e111ed1233fd71","lab_id":"69ad52a4de79e566650fd4a8","country":"CZ","accr_number":"1576","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie wilgotności gazu","methodology_en":"Determination of gas moisture","methodology_zh":"气体湿度的测定","methodology_cs":"Stanovení vlhkosti plynu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"czujnik pojemnościowy","technique_en":"capacitive sensor","technique_zh":"电容式传感器","technique_cs":"kapacitní čidlo","techniques":["czujnik pojemnościowy"],"techniques_en":["capacitive sensor"],"techniques_zh":["电容式传感器"],"techniques_cs":["kapacitní čidlo"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności gazu\nczujnik pojemnościowy","reference":"SOP 007 (návod firmy E+E Elektronik)","norm_bases":["SOP 007","návod firmy E+E Elektronik"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie wilgotności gazu czujnik pojemnościowy Emise Stanovení vlhkosti plynu kapacitní čidlo SOP 007 (návod firmy E+E Elektronik) Emisja Oznaczanie wilgotnosci gazu czujnik pojemnosciowy Emise Stanoveni vlhkosti plynu kapacitni cidlo SOP 007 (navod firmy E+E Elektronik)","search_en":"Emissions Determination of gas moisture capacitive sensor SOP 007 (návod firmy E+E Elektronik)","search_zh":"排放 气体湿度的测定 电容式传感器 SOP 007 (návod firmy E+E Elektronik)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"11a0d665811290a0c8af94e5","lab_id":"69ad52a4de79e566650fd4a8","country":"CZ","accr_number":"1576","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie tlenu analizatorami automatycznymi metodą paramagnetyczną","methodology_en":"Determination of oxygen by automated analysers using the paramagnetic method","methodology_zh":"顺磁法自动分析仪测定氧","methodology_cs":"Stanovení kyslíku automatizovanými analyzátory paramagnetickou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu analizatorami automatycznymi metodą paramagnetyczną","reference":"SOP 009 (ČSN EN 14789)","norm_bases":["SOP 009","ČSN EN 14789"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie tlenu analizatorami automatycznymi metodą paramagnetyczną Emise Stanovení kyslíku automatizovanými analyzátory paramagnetickou metodou SOP 009 (ČSN EN 14789) Emisja Oznaczanie tlenu analizatorami automatycznymi metoda paramagnetyczna Emise Stanoveni kysliku automatizovanymi analyzatory paramagnetickou metodou SOP 009 (CSN EN 14789)","search_en":"Emissions Determination of oxygen by automated analysers using the paramagnetic method SOP 009 (ČSN EN 14789)","search_zh":"排放 顺磁法自动分析仪测定氧 SOP 009 (ČSN EN 14789)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb19951b6371fd10fde44ec9","lab_id":"69ad52a4de79e566650fd4a8","country":"CZ","accr_number":"1576","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi metodą NDIR","methodology_en":"Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers using the NDIR method","methodology_zh":"NDIR法自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOx, CO) automatizovanými analyzátory metodou NDIR","parameters":[{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki azotu (NOx)","range":""},{"name":"Tlenek węgla (CO)","range":""}],"parameters_en":[{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Nitrogen oxides (NOx)","range":""},{"name":"Carbon monoxide (CO)","range":""}],"parameters_zh":[{"name":"二氧化硫（SO2）","range":""},{"name":"氮氧化物（NOx）","range":""},{"name":"一氧化碳（CO）","range":""}],"parameters_cs":[{"name":"SO2","range":""},{"name":"NOx","range":""},{"name":"CO","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi metodą NDIR\nZakres:\nDitlenek siarki (SO2)\nTlenki azotu (NOx)\nTlenek węgla (CO)","reference":"SOP 010 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","norm_bases":["SOP 010","ČSN ISO 7935","ČSN ISO 10849","ČSN EN 15058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi metodą NDIR Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek węgla (CO)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOx, CO) automatizovanými analyzátory metodou NDIR SO2  NOx  CO  SOP 010 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych (SO2, NOx, CO) analizatorami automatycznymi metoda NDIR Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek wegla (CO)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek (SO2, NOx, CO) automatizovanymi analyzatory metodou NDIR SO2  NOx  CO  SOP 010 (CSN ISO 7935, CSN ISO 10849, CSN EN 15058)","search_en":"Emissions Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers using the NDIR method Sulphur dioxide (SO2)  Nitrogen oxides (NOx)  Carbon monoxide (CO)  SOP 010 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","search_zh":"排放 NDIR法自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度 二氧化硫（SO2）  氮氧化物（NOx）  一氧化碳（CO）  SOP 010 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bed34ee5f00b7207c1167679","lab_id":"69ad52a4de79e566650fd4a8","country":"CZ","accr_number":"1576","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających","methodology_en":"Determination of mass concentration of particulate pollutants","methodology_zh":"颗粒污染物质量浓度的测定","methodology_cs":"Stanovení hmotnostní koncentrace tuhých znečišťujících látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"grawimetria","technique_en":"gravimetry","technique_zh":"重量法","technique_cs":"gravimetrie","techniques":["grawimetria"],"techniques_en":["gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających\ngrawimetria","reference":"SOP 006 (ČSN ISO 9096:1998, ČSN EN 13284-1)","norm_bases":["SOP 006","ČSN ISO 9096:1998","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających grawimetria Emise Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetrie SOP 006 (ČSN ISO 9096:1998, ČSN EN 13284-1) Emisja Oznaczanie stezenia masowego pylowych substancji zanieczyszczajacych grawimetria Emise Stanoveni hmotnostni koncentrace tuhych znecistujicich latek gravimetrie SOP 006 (CSN ISO 9096:1998, CSN EN 13284-1)","search_en":"Emissions Determination of mass concentration of particulate pollutants gravimetry SOP 006 (ČSN ISO 9096:1998, ČSN EN 13284-1)","search_zh":"排放 颗粒污染物质量浓度的测定 重量法 SOP 006 (ČSN ISO 9096:1998, ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0e361261f32a57484a215ccc","lab_id":"69ad52a4de79e566650fd4a8","country":"CZ","accr_number":"1576","accr_body":"ČIA","row_label":"6","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorem automatycznym","methodology_en":"Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analyser","methodology_zh":"自动分析仪测定以总有机碳（TOC）表示的有机物总质量浓度","methodology_cs":"Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovaným analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"detektor płomieniowo-jonizacyjny (FID)","technique_en":"flame ionisation detector (FID)","technique_zh":"火焰离子化检测器（FID）","technique_cs":"FID","techniques":["detektor płomieniowo-jonizacyjny (FID)"],"techniques_en":["flame ionisation detector (FID)"],"techniques_zh":["火焰离子化检测器（FID）"],"techniques_cs":["FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorem automatycznym\ndetektor płomieniowo-jonizacyjny (FID)","reference":"SOP 008 (ČSN EN 12619, ČSN EN 13526:2002)","norm_bases":["SOP 008","ČSN EN 12619","ČSN EN 13526:2002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorem automatycznym detektor płomieniowo-jonizacyjny (FID) Emise Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovaným analyzátorem FID SOP 008 (ČSN EN 12619, ČSN EN 13526:2002) Emisja Oznaczanie sumarycznego stezenia masowego substancji organicznych wyrazonych jako calkowity wegiel organiczny (TOC) analizatorem automatycznym detektor plomieniowo-jonizacyjny (FID) Emise Stanoveni uhrnne hmotnostni koncentrace organickych latek vyjadrenych jako celkovy organicky uhlik (TOC) automatizovanym analyzatorem FID SOP 008 (CSN EN 12619, CSN EN 13526:2002)","search_en":"Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analyser flame ionisation detector (FID) SOP 008 (ČSN EN 12619, ČSN EN 13526:2002)","search_zh":"排放 自动分析仪测定以总有机碳（TOC）表示的有机物总质量浓度 火焰离子化检测器（FID） SOP 008 (ČSN EN 12619, ČSN EN 13526:2002)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"40e13b10e780777f00a151d8","lab_id":"69ad52a4de79e566650fd4a8","country":"CZ","accr_number":"1576","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek pyłowych substancji zanieczyszczających","methodology_en":"Sampling of particulate pollutants","methodology_zh":"颗粒污染物采样","methodology_cs":"Odběr vzorku tuhých znečišťujících látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"pobór ręczny i izokinetyczny z automatyczną regulacją izokinetyki","technique_en":"manual and isokinetic sampling with automatic isokinetic control","technique_zh":"手动和自动等速控制的等速采样","technique_cs":"manuální a izokinetický odběr s automatickým řízením izokinetiky","techniques":["pobór ręczny i izokinetyczny z automatyczną regulacją izokinetyki"],"techniques_en":["manual and isokinetic sampling with automatic isokinetic control"],"techniques_zh":["手动和自动等速控制的等速采样"],"techniques_cs":["manuální a izokinetický odběr s automatickým řízením izokinetiky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek pyłowych substancji zanieczyszczających\npobór ręczny i izokinetyczny z automatyczną regulacją izokinetyki","reference":"SOP 002 (ČSN ISO 9096:1998, ČSN EN 13284-1)","norm_bases":["SOP 002","ČSN ISO 9096:1998","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek pyłowych substancji zanieczyszczających pobór ręczny i izokinetyczny z automatyczną regulacją izokinetyki Emise Odběr vzorku tuhých znečišťujících látek manuální a izokinetický odběr s automatickým řízením izokinetiky SOP 002 (ČSN ISO 9096:1998, ČSN EN 13284-1) Emisja Pobieranie probek pylowych substancji zanieczyszczajacych pobor reczny i izokinetyczny z automatyczna regulacja izokinetyki Emise Odber vzorku tuhych znecistujicich latek manualni a izokineticky odber s automatickym rizenim izokinetiky SOP 002 (CSN ISO 9096:1998, CSN EN 13284-1)","search_en":"Emissions Sampling of particulate pollutants manual and isokinetic sampling with automatic isokinetic control SOP 002 (ČSN ISO 9096:1998, ČSN EN 13284-1)","search_zh":"排放 颗粒污染物采样 手动和自动等速控制的等速采样 SOP 002 (ČSN ISO 9096:1998, ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}