🇨🇿 AXIA CZ s.r.o. PL
Environment
AXIA CZ s.r.o. is a laboratory accredited by ČIA under number 1571 (Lanškroun, Czech Republic). Its accreditation scope covers 11 test methods in the following areas: Environment. Test objects include: Emissions.
At a glance
- Accreditation number: ČIA 1571
- Methods in scope: 11
- Types of test objects: 1
- City: Lanškroun, Czech Republic
- Valid until: 03-10-2027
- Accreditation number
- 1571
- Accreditation body
- ČIA
- Address
- Dolní Třešňovec 30, 563 01 Lanškroun
- City
- Lanškroun, Czech Republic
- Division
- Dział Pomiarów Emisji
- Valid until
- 03-10-2027
What this laboratory tests (1)
- Emissions — 11 methods
Certificate information
- Certificate date
- 03.10.2022
Accreditation scope — test methods (11)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of flow velocity and volume flow rate Regulated area: Tests |
SOP 01 část A (ČSN ISO 10780) | ||
| 2 | Emissions | Determination of moisture by condensation method Regulated area: Tests |
SOP 01 část B (ČSN EN 14790) | ||
| 3 | Emissions | Determination of mass concentration of gaseous pollutants by automated NDIR analysers (SO2, NOx, CO) Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO) Regulated area: Tests |
SOP 02 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058) | ||
| 4 | Emissions | Determination of volume concentration of O2 by paramagnetic method Regulated area: Tests |
SOP 03 (ČSN EN 14789) | ||
| 5 | Emissions | Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers with flame ionisation detection Regulated area: Tests |
SOP 04 (ČSN EN 12619) | ||
| 6 | Emissions | Determination of mass concentration of particulate pollutants by manual gravimetric method Regulated area: Tests |
SOP 05 část B (ČSN EN 13284-1) | ||
| 7 | Emissions | Determination of mass concentration of metals by calculation from measured values (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) Arsenic (As) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Hexavalent chromium (Cr6+) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Tellurium (Te) Thallium (Tl) Vanadium (V) Zinc (Zn) Regulated area: Tests |
SOP 06 část B (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061) | ||
| 8 | Emissions | Determination of mass concentration of gases and vapours by calculation from measured values (H+, CN-, HCl, Cl-, HF, F-, NH3) Hydrogen ions (H+) Cyanides (CN-) Hydrogen chloride (HCl) Chlorides (Cl-) Hydrogen fluoride (HF) Fluorides (F-) Ammonia (NH3) Regulated area: Tests |
SOP 07 část B (ČSN EN 1911, ČSN 83 4752-1:1990, ČSN 83 4728-1) | ||
| 9 | Emissions | Sampling of particulate pollutants with manual isokinetic control Regulated area: Sampling |
SOP 05 část A (ČSN EN 13284-1) | ||
| 10 | Emissions | Sampling of heavy metals - by isokinetic sampling and absorption into liquid (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) Regulated area: Sampling |
SOP 06 část A (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061) | ||
| 11 | Emissions | Sampling of gases and vapours by absorption into liquid (H+, CN-, HCl, Cl-, HF, F-, NH3) Regulated area: Sampling |
SOP 07 část A (ČSN EN 1911, ČSN 83 4752-2:1990, ČSN 83 4728-2) | ||
Reference standards (27)
SOP 01 část A
SOP 01 část B
SOP 02
SOP 03
SOP 04
SOP 05 část A
SOP 05 část B
SOP 06 část A
SOP 06 část B
SOP 07 část A
SOP 07 část B
US EPA 0061
US EPA 29
ČSN 83 4728-1
ČSN 83 4728-2
ČSN 83 4752-1:1990
ČSN 83 4752-2:1990
ČSN EN 12619
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935