{"lab":{"_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","address":"Dolní Třešňovec 30, 563 01 Lanškroun","categories":["environment"],"city":"Lanškroun","imported_at":"2026-03-08T10:42:44.590Z","methods_count":11,"name":"AXIA CZ s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1571_468_2022_CS.pdf","1571_468_2022_EN.pdf"],"scope_summary":"Pomiary emisji substancji zanieczyszczających w gazach odlotowych ze stacjonarnych źródeł zanieczyszczeń.","search_text":"axia cz s.r.o. dolní třešňovec 30, 563 01 lanškroun 1571","status":"active","updated_at":"2026-03-08T14:52:13.569Z","valid_from":"","valid_until":"03-10-2027","website":"www.axialan.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.axialan.cz","map_coord":[49.92605,16.610645],"map_geo":"nominatim-street","certificate_date":"03.10.2022","certificate_no":"468/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary emisji substancji zanieczyszczających w gazach odlotowych ze stacjonarnych źródeł zanieczyszczeń.","en":"Measurement of emissions of pollutants in waste gas from stationary sources of pollution.","zh":"固定污染源废气中污染物排放的测量。","cs":"Měření emisí znečisťujících látek v odpadním plynu ze stacionárních zdrojů znečisťování."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Dział Pomiarów Emisji","lab_division_cs":"Útvar měření emisí","lab_division_en":"Emission Measurement Unit","lab_division_zh":"排放测量部","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"SOP","pl":"standardowa procedura operacyjna Działu Pomiarów Emisji","en":"standard operating procedure of the Emission Measurement Unit","zh":"排放测量部标准操作程序","cs":"standardní operační postup Útvaru měření emisí"},{"abbr":"NDIR","pl":"niedyspersyjna spektrometria w podczerwieni","en":"non-dispersive infrared spectrometry","zh":"非分散红外光谱法","cs":"nedisperzní infračervená spektrometrie"},{"abbr":"TOC","pl":"całkowity węgiel organiczny","en":"total organic carbon","zh":"总有机碳","cs":"celkový organický uhlík"},{"abbr":"Emise","pl":"gaz odlotowy zawierający substancje zanieczyszczające, odprowadzany w sposób zorganizowany lub uchodzący do powietrza atmosferycznego ze źródeł zanieczyszczania powietrza","en":"waste gas containing pollutants that is discharged in a controlled manner or escapes into the outdoor atmosphere from sources of air pollution","zh":"从大气污染源以受控方式排放或逸散到室外大气中的含污染物废气","cs":"odpadní plyn s obsahem znečišťujících látek, který je odváděn řízeným způsobem nebo uniká do venkovní atmosféry ze zdrojů znečišťování ovzduší"},{"abbr":"US EPA","pl":"Agencja Ochrony Środowiska Stanów Zjednoczonych (United States Environmental Protection Agency)","en":"United States Environmental Protection Agency","zh":"美国环境保护署","cs":"United States Environmental Protection Agency"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"329cfe4bd3b0694871679142f9af7986cf89f7cd6746052a009c280dbd70ffdc","source_pdf_url":"https://www.cai.cz/OA/pdf/P468_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"20e47bc098fbe0136f68a585","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie prędkości przepływu i strumienia objętości","methodology_en":"Determination of flow velocity and volume flow rate","methodology_zh":"流速和体积流量的测定","methodology_cs":"Stanovení rychlosti proudění a objemového toku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prędkości przepływu i strumienia objętości","reference":"SOP 01 část A (ČSN ISO 10780)","norm_bases":["SOP 01 část A","ČSN ISO 10780"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie prędkości przepływu i strumienia objętości Emise Stanovení rychlosti proudění a objemového toku SOP 01 část A (ČSN ISO 10780) Emisja Oznaczanie predkosci przeplywu i strumienia objetosci Emise Stanoveni rychlosti proudeni a objemoveho toku SOP 01 cast A (CSN ISO 10780)","search_en":"Emissions Determination of flow velocity and volume flow rate SOP 01 část A (ČSN ISO 10780)","search_zh":"排放 流速和体积流量的测定 SOP 01 část A (ČSN ISO 10780)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6df5a398aa453c4c7d7069b1","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie wilgotności metodą kondensacyjną","methodology_en":"Determination of moisture by condensation method","methodology_zh":"冷凝法测定湿度","methodology_cs":"Stanovení vlhkosti kondenzační metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności metodą kondensacyjną","reference":"SOP 01 část B (ČSN EN 14790)","norm_bases":["SOP 01 část B","ČSN EN 14790"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie wilgotności metodą kondensacyjną Emise Stanovení vlhkosti kondenzační metodou SOP 01 část B (ČSN EN 14790) Emisja Oznaczanie wilgotnosci metoda kondensacyjna Emise Stanoveni vlhkosti kondenzacni metodou SOP 01 cast B (CSN EN 14790)","search_en":"Emissions Determination of moisture by condensation method SOP 01 část B (ČSN EN 14790)","search_zh":"排放 冷凝法测定湿度 SOP 01 část B (ČSN EN 14790)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7439475ed5ff421e35e7b8c8","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających analizatorami automatycznymi NDIR (SO2, NOx, CO)","methodology_en":"Determination of mass concentration of gaseous pollutants by automated NDIR analysers (SO2, NOx, CO)","methodology_zh":"NDIR自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek automatizovanými analyzátory NDIR (SO2, NOx, CO)","parameters":[{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki azotu (NOx)","range":""},{"name":"Tlenek węgla (CO)","range":""}],"parameters_en":[{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Nitrogen oxides (NOx)","range":""},{"name":"Carbon monoxide (CO)","range":""}],"parameters_zh":[{"name":"二氧化硫（SO2）","range":""},{"name":"氮氧化物（NOx）","range":""},{"name":"一氧化碳（CO）","range":""}],"parameters_cs":[{"name":"SO2","range":""},{"name":"NOx","range":""},{"name":"CO","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających analizatorami automatycznymi NDIR (SO2, NOx, CO)\nZakres:\nDitlenek siarki (SO2)\nTlenki azotu (NOx)\nTlenek węgla (CO)","reference":"SOP 02 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","norm_bases":["SOP 02","ČSN ISO 7935","ČSN ISO 10849","ČSN EN 15058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających analizatorami automatycznymi NDIR (SO2, NOx, CO) Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek węgla (CO)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek automatizovanými analyzátory NDIR (SO2, NOx, CO) SO2  NOx  CO  SOP 02 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych analizatorami automatycznymi NDIR (SO2, NOx, CO) Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek wegla (CO)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek automatizovanymi analyzatory NDIR (SO2, NOx, CO) SO2  NOx  CO  SOP 02 (CSN ISO 7935, CSN ISO 10849, CSN EN 15058)","search_en":"Emissions Determination of mass concentration of gaseous pollutants by automated NDIR analysers (SO2, NOx, CO) Sulphur dioxide (SO2)  Nitrogen oxides (NOx)  Carbon monoxide (CO)  SOP 02 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","search_zh":"排放 NDIR自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度 二氧化硫（SO2）  氮氧化物（NOx）  一氧化碳（CO）  SOP 02 (ČSN ISO 7935, ČSN ISO 10849, ČSN EN 15058)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6286b17488741a0bd730606c","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia objętościowego O2 metodą paramagnetyczną","methodology_en":"Determination of volume concentration of O2 by paramagnetic method","methodology_zh":"顺磁法测定O2的体积浓度","methodology_cs":"Stanovení objemové koncentrace O2 paramagnetickou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia objętościowego O2 metodą paramagnetyczną","reference":"SOP 03 (ČSN EN 14789)","norm_bases":["SOP 03","ČSN EN 14789"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia objętościowego O2 metodą paramagnetyczną Emise Stanovení objemové koncentrace O2 paramagnetickou metodou SOP 03 (ČSN EN 14789) Emisja Oznaczanie stezenia objetosciowego O2 metoda paramagnetyczna Emise Stanoveni objemove koncentrace O2 paramagnetickou metodou SOP 03 (CSN EN 14789)","search_en":"Emissions Determination of volume concentration of O2 by paramagnetic method SOP 03 (ČSN EN 14789)","search_zh":"排放 顺磁法测定O2的体积浓度 SOP 03 (ČSN EN 14789)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d20f31d7b15fcb6b90488ced","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi z detekcją płomieniowo-jonizacyjną","methodology_en":"Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers with flame ionisation detection","methodology_zh":"带火焰离子化检测的自动分析仪测定以总有机碳（TOC）表示的有机物总质量浓度","methodology_cs":"Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory s plamenoionizační detekcí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi z detekcją płomieniowo-jonizacyjną","reference":"SOP 04 (ČSN EN 12619)","norm_bases":["SOP 04","ČSN EN 12619"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi z detekcją płomieniowo-jonizacyjną Emise Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory s plamenoionizační detekcí SOP 04 (ČSN EN 12619) Emisja Oznaczanie sumarycznego stezenia masowego substancji organicznych wyrazonych jako calkowity wegiel organiczny (TOC) analizatorami automatycznymi z detekcja plomieniowo-jonizacyjna Emise Stanoveni uhrnne hmotnostni koncentrace organickych latek vyjadrenych jako celkovy organicky uhlik (TOC) automatizovanymi analyzatory s plamenoionizacni detekci SOP 04 (CSN EN 12619)","search_en":"Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers with flame ionisation detection SOP 04 (ČSN EN 12619)","search_zh":"排放 带火焰离子化检测的自动分析仪测定以总有机碳（TOC）表示的有机物总质量浓度 SOP 04 (ČSN EN 12619)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"016e599cc36b8a8c1d57b30c","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"6","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających ręczną metodą grawimetryczną","methodology_en":"Determination of mass concentration of particulate pollutants by manual gravimetric method","methodology_zh":"手动重量法测定颗粒污染物的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace tuhých znečišťujících látek manuální gravimetrickou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających ręczną metodą grawimetryczną","reference":"SOP 05 část B (ČSN EN 13284-1)","norm_bases":["SOP 05 část B","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających ręczną metodą grawimetryczną Emise Stanovení hmotnostní koncentrace tuhých znečišťujících látek manuální gravimetrickou metodou SOP 05 část B (ČSN EN 13284-1) Emisja Oznaczanie stezenia masowego pylowych substancji zanieczyszczajacych reczna metoda grawimetryczna Emise Stanoveni hmotnostni koncentrace tuhych znecistujicich latek manualni gravimetrickou metodou SOP 05 cast B (CSN EN 13284-1)","search_en":"Emissions Determination of mass concentration of particulate pollutants by manual gravimetric method SOP 05 část B (ČSN EN 13284-1)","search_zh":"排放 手动重量法测定颗粒污染物的质量浓度 SOP 05 část B (ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc703e4b44e65e1b19296dcb","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"7","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)","methodology_en":"Determination of mass concentration of metals by calculation from measured values (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)","methodology_zh":"由测量值计算测定金属（As、Cd、Co、Cr、Cr6+、Cu、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace kovů výpočtem z naměřených hodnot (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)","parameters":[{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Chrom sześciowartościowy (Cr6+)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Tellur (Te)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Hexavalent chromium (Cr6+)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Tellurium (Te)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"六价铬（Cr6+）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"碲（Te）","range":""},{"name":"铊（Tl）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cr6+","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Te","range":""},{"name":"Tl","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)\nZakres:\nArsen (As)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nChrom sześciowartościowy (Cr6+)\nMiedź (Cu)\nMangan (Mn)\nNikiel (Ni)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nTellur (Te)\nTal (Tl)\nWanad (V)\nCynk (Zn)","reference":"SOP 06 část B (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061)","norm_bases":["SOP 06 část B","ČSN EN 14385","ČSN EN 13284-1","US EPA 29","US EPA 0061"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"procedura badawcza jest wykonywana przez zewnętrznego dostawcę – w podwykonawstwie","note_en":"the test procedure is performed by an external supplier - subcontracted","note_zh":"该检测程序由外部供方以分包方式执行","note_cs":"zkušební postup je prováděn externím dodavatelem - subdodavatelsky","search_text":"Emisja Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) Arsen (As)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Chrom sześciowartościowy (Cr6+)  Miedź (Cu)  Mangan (Mn)  Nikiel (Ni)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Emise Stanovení hmotnostní koncentrace kovů výpočtem z naměřených hodnot (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) As  Cd  Co  Cr  Cr6+  Cu  Mn  Ni  Pb  Sb  Se  Sn  Te  Tl  V  Zn  SOP 06 část B (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061) Emisja Oznaczanie stezenia masowego metali obliczeniowo z wartosci zmierzonych (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) Arsen (As)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Chrom szesciowartosciowy (Cr6+)  Miedz (Cu)  Mangan (Mn)  Nikiel (Ni)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Emise Stanoveni hmotnostni koncentrace kovu vypoctem z namerenych hodnot (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) As  Cd  Co  Cr  Cr6+  Cu  Mn  Ni  Pb  Sb  Se  Sn  Te  Tl  V  Zn  SOP 06 cast B (CSN EN 14385, CSN EN 13284-1, US EPA 29, US EPA 0061)","search_en":"Emissions Determination of mass concentration of metals by calculation from measured values (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) Arsenic (As)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Hexavalent chromium (Cr6+)  Copper (Cu)  Manganese (Mn)  Nickel (Ni)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Tellurium (Te)  Thallium (Tl)  Vanadium (V)  Zinc (Zn)  SOP 06 část B (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061)","search_zh":"排放 由测量值计算测定金属（As、Cd、Co、Cr、Cr6+、Cu、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn）的质量浓度 砷（As）  镉（Cd）  钴（Co）  铬（Cr）  六价铬（Cr6+）  铜（Cu）  锰（Mn）  镍（Ni）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  碲（Te）  铊（Tl）  钒（V）  锌（Zn）  SOP 06 část B (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22518c980e59359d0348b291","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"8","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazów i par obliczeniowo z wartości zmierzonych (H+, CN-, HCl, Cl-, HF, F-, NH3)","methodology_en":"Determination of mass concentration of gases and vapours by calculation from measured values (H+, CN-, HCl, Cl-, HF, F-, NH3)","methodology_zh":"由测量值计算测定气体和蒸气（H+、CN-、HCl、Cl-、HF、F-、NH3）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynů a par výpočtem z naměřených hodnot (H+, CN-, HCl, Cl-, HF, F-, NH3)","parameters":[{"name":"Jony wodorowe (H+)","range":""},{"name":"Cyjanki (CN-)","range":""},{"name":"Chlorowodór (HCl)","range":""},{"name":"Chlorki (Cl-)","range":""},{"name":"Fluorowodór (HF)","range":""},{"name":"Fluorki (F-)","range":""},{"name":"Amoniak (NH3)","range":""}],"parameters_en":[{"name":"Hydrogen ions (H+)","range":""},{"name":"Cyanides (CN-)","range":""},{"name":"Hydrogen chloride (HCl)","range":""},{"name":"Chlorides (Cl-)","range":""},{"name":"Hydrogen fluoride (HF)","range":""},{"name":"Fluorides (F-)","range":""},{"name":"Ammonia (NH3)","range":""}],"parameters_zh":[{"name":"氢离子（H+）","range":""},{"name":"氰化物（CN-）","range":""},{"name":"氯化氢（HCl）","range":""},{"name":"氯化物（Cl-）","range":""},{"name":"氟化氢（HF）","range":""},{"name":"氟化物（F-）","range":""},{"name":"氨（NH3）","range":""}],"parameters_cs":[{"name":"H+","range":""},{"name":"CN-","range":""},{"name":"HCl","range":""},{"name":"Cl-","range":""},{"name":"HF","range":""},{"name":"F-","range":""},{"name":"NH3","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazów i par obliczeniowo z wartości zmierzonych (H+, CN-, HCl, Cl-, HF, F-, NH3)\nZakres:\nJony wodorowe (H+)\nCyjanki (CN-)\nChlorowodór (HCl)\nChlorki (Cl-)\nFluorowodór (HF)\nFluorki (F-)\nAmoniak (NH3)","reference":"SOP 07 část B (ČSN EN 1911, ČSN 83 4752-1:1990, ČSN 83 4728-1)","norm_bases":["SOP 07 část B","ČSN EN 1911","ČSN 83 4752-1:1990","ČSN 83 4728-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"procedura badawcza jest wykonywana przez zewnętrznego dostawcę – w podwykonawstwie","note_en":"the test procedure is performed by an external supplier - subcontracted","note_zh":"该检测程序由外部供方以分包方式执行","note_cs":"zkušební postup je prováděn externím dodavatelem - subdodavatelsky","search_text":"Emisja Oznaczanie stężenia masowego gazów i par obliczeniowo z wartości zmierzonych (H+, CN-, HCl, Cl-, HF, F-, NH3) Jony wodorowe (H+)  Cyjanki (CN-)  Chlorowodór (HCl)  Chlorki (Cl-)  Fluorowodór (HF)  Fluorki (F-)  Amoniak (NH3)  Emise Stanovení hmotnostní koncentrace plynů a par výpočtem z naměřených hodnot (H+, CN-, HCl, Cl-, HF, F-, NH3) H+  CN-  HCl  Cl-  HF  F-  NH3  SOP 07 část B (ČSN EN 1911, ČSN 83 4752-1:1990, ČSN 83 4728-1) Emisja Oznaczanie stezenia masowego gazow i par obliczeniowo z wartosci zmierzonych (H+, CN-, HCl, Cl-, HF, F-, NH3) Jony wodorowe (H+)  Cyjanki (CN-)  Chlorowodor (HCl)  Chlorki (Cl-)  Fluorowodor (HF)  Fluorki (F-)  Amoniak (NH3)  Emise Stanoveni hmotnostni koncentrace plynu a par vypoctem z namerenych hodnot (H+, CN-, HCl, Cl-, HF, F-, NH3) H+  CN-  HCl  Cl-  HF  F-  NH3  SOP 07 cast B (CSN EN 1911, CSN 83 4752-1:1990, CSN 83 4728-1)","search_en":"Emissions Determination of mass concentration of gases and vapours by calculation from measured values (H+, CN-, HCl, Cl-, HF, F-, NH3) Hydrogen ions (H+)  Cyanides (CN-)  Hydrogen chloride (HCl)  Chlorides (Cl-)  Hydrogen fluoride (HF)  Fluorides (F-)  Ammonia (NH3)  SOP 07 část B (ČSN EN 1911, ČSN 83 4752-1:1990, ČSN 83 4728-1)","search_zh":"排放 由测量值计算测定气体和蒸气（H+、CN-、HCl、Cl-、HF、F-、NH3）的质量浓度 氢离子（H+）  氰化物（CN-）  氯化氢（HCl）  氯化物（Cl-）  氟化氢（HF）  氟化物（F-）  氨（NH3）  SOP 07 část B (ČSN EN 1911, ČSN 83 4752-1:1990, ČSN 83 4728-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b05157b3594abccb1e7de93","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek pyłowych substancji zanieczyszczających z ręczną regulacją izokinetyki","methodology_en":"Sampling of particulate pollutants with manual isokinetic control","methodology_zh":"手动等速控制的颗粒污染物采样","methodology_cs":"Odběr vzorků tuhých znečišťujících látek s manuálním řízením izokinetiky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek pyłowych substancji zanieczyszczających z ręczną regulacją izokinetyki","reference":"SOP 05 část A (ČSN EN 13284-1)","norm_bases":["SOP 05 část A","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek pyłowych substancji zanieczyszczających z ręczną regulacją izokinetyki Emise Odběr vzorků tuhých znečišťujících látek s manuálním řízením izokinetiky SOP 05 část A (ČSN EN 13284-1) Emisja Pobieranie probek pylowych substancji zanieczyszczajacych z reczna regulacja izokinetyki Emise Odber vzorku tuhych znecistujicich latek s manualnim rizenim izokinetiky SOP 05 cast A (CSN EN 13284-1)","search_en":"Emissions Sampling of particulate pollutants with manual isokinetic control SOP 05 část A (ČSN EN 13284-1)","search_zh":"排放 手动等速控制的颗粒污染物采样 SOP 05 část A (ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41eadd97f05a3edafe6f7435","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek metali ciężkich – poborem izokinetycznym i absorpcją w cieczy (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)","methodology_en":"Sampling of heavy metals - by isokinetic sampling and absorption into liquid (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)","methodology_zh":"重金属采样 – 等速采样和液体吸收（As、Cd、Co、Cr、Cr6+、Cu、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn）","methodology_cs":"Odběr vzorků těžkých kovů - izokinetickým odběrem a absorpcí do kapaliny (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek metali ciężkich – poborem izokinetycznym i absorpcją w cieczy (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn)","reference":"SOP 06 část A (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061)","norm_bases":["SOP 06 část A","ČSN EN 14385","ČSN EN 13284-1","US EPA 29","US EPA 0061"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek metali ciężkich – poborem izokinetycznym i absorpcją w cieczy (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) Emise Odběr vzorků těžkých kovů - izokinetickým odběrem a absorpcí do kapaliny (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) SOP 06 část A (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061) Emisja Pobieranie probek metali ciezkich – poborem izokinetycznym i absorpcja w cieczy (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) Emise Odber vzorku tezkych kovu - izokinetickym odberem a absorpci do kapaliny (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) SOP 06 cast A (CSN EN 14385, CSN EN 13284-1, US EPA 29, US EPA 0061)","search_en":"Emissions Sampling of heavy metals - by isokinetic sampling and absorption into liquid (As, Cd, Co, Cr, Cr6+, Cu, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) SOP 06 část A (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061)","search_zh":"排放 重金属采样 – 等速采样和液体吸收（As、Cd、Co、Cr、Cr6+、Cu、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn） SOP 06 část A (ČSN EN 14385, ČSN EN 13284-1, US EPA 29, US EPA 0061)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0b47dd523f7a8f4e05a96556","lab_id":"69ad52a4de79e566650fd4a6","country":"CZ","accr_number":"1571","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek gazów i par przez absorpcję w cieczy (H+, CN-, HCl, Cl-, HF, F-, NH3)","methodology_en":"Sampling of gases and vapours by absorption into liquid (H+, CN-, HCl, Cl-, HF, F-, NH3)","methodology_zh":"液体吸收法采集气体和蒸气样品（H+、CN-、HCl、Cl-、HF、F-、NH3）","methodology_cs":"Odběr vzorků plynů a par absorpcí do kapaliny (H+, CN-, HCl, Cl-, HF, F-, NH3)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gazów i par przez absorpcję w cieczy (H+, CN-, HCl, Cl-, HF, F-, NH3)","reference":"SOP 07 část A (ČSN EN 1911, ČSN 83 4752-2:1990, ČSN 83 4728-2)","norm_bases":["SOP 07 část A","ČSN EN 1911","ČSN 83 4752-2:1990","ČSN 83 4728-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek gazów i par przez absorpcję w cieczy (H+, CN-, HCl, Cl-, HF, F-, NH3) Emise Odběr vzorků plynů a par absorpcí do kapaliny (H+, CN-, HCl, Cl-, HF, F-, NH3) SOP 07 část A (ČSN EN 1911, ČSN 83 4752-2:1990, ČSN 83 4728-2) Emisja Pobieranie probek gazow i par przez absorpcje w cieczy (H+, CN-, HCl, Cl-, HF, F-, NH3) Emise Odber vzorku plynu a par absorpci do kapaliny (H+, CN-, HCl, Cl-, HF, F-, NH3) SOP 07 cast A (CSN EN 1911, CSN 83 4752-2:1990, CSN 83 4728-2)","search_en":"Emissions Sampling of gases and vapours by absorption into liquid (H+, CN-, HCl, Cl-, HF, F-, NH3) SOP 07 část A (ČSN EN 1911, ČSN 83 4752-2:1990, ČSN 83 4728-2)","search_zh":"排放 液体吸收法采集气体和蒸气样品（H+、CN-、HCl、Cl-、HF、F-、NH3） SOP 07 část A (ČSN EN 1911, ČSN 83 4752-2:1990, ČSN 83 4728-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}