🇨🇿 TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ BRNO, spol. s r. o. PL

ČIA 1568 • Brno, Czech Republic • 17 methods

Environment

TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ BRNO, spol. s r. o. is a laboratory accredited by ČIA under number 1568 (Brno, Czech Republic). Its accreditation scope covers 17 test methods in the following areas: Environment. Test objects include: Emissions, Automated emission measuring systems. Most frequently used techniques: chemiluminescence, condensation method, adsorption method, capacitive sensor, FID (flame ionisation detection).

At a glance

  • Accreditation number: ČIA 1568
  • Methods in scope: 17
  • Types of test objects: 2
  • Techniques used: 6
  • City: Brno, Czech Republic
  • Valid until: 13-07-2027
Accreditation number
1568
Accreditation body
ČIA
Address
Zeleného 3107/50, 616 00 Brno
City
Brno, Czech Republic
Division
Laboratorium Badawcze Pomiarów Substancji Zanieczyszczających
Valid until
13-07-2027

What this laboratory tests (2)

Analytical techniques used (6)

Certificate information

Certificate date
13.07.2022

Accreditation scope — test methods (17)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of flow velocity and volume flow rate
Regulated area: Tests
SOP č. 1 (ČSN ISO 10780, ČSN EN ISO 16911-1)
2 Emissions Determination of gas moisture
Regulated area: Tests
condensation method, adsorption method, capacitive sensor SOP č. 2 (ČSN EN 14790)
3 Emissions Determination of volume concentration of oxygen (O2) by automated analysers
Regulated area: Tests
paramagnetic method SOP č. 4 – část A, B3 (ČSN EN 14789)
4 Emissions Determination of mass concentration of gaseous pollutants (SO2, CO) and volume concentration of CO2 by automated analysers
Sulphur dioxide (SO2) Carbon monoxide (CO) Carbon dioxide (CO2)
Regulated area: Tests
non-dispersive infrared spectroscopy SOP č. 4 – část A, B1 (ČSN ISO 7935, ČSN EN 15058)
5 Emissions Determination of mass concentration of gaseous pollutants (NOx) by automated analysers
Nitrogen oxides (NOx)
Regulated area: Tests
chemiluminescence SOP č. 4 – část A, B2 (ČSN EN 14792)
6 Emissions Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers (FID)
Regulated area: Tests
FID (flame ionisation detection) SOP č. 5 (ČSN EN 12619)
7 Emissions Determination of mass concentration of organic substances (VOC) after trapping on solid sorbent by calculation from measured values
Regulated area: Tests
SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)
8 Emissions Determination of mass concentration of particulate pollutants
Regulated area: Tests
gravimetry SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)
9 Emissions Determination of mass concentration of metals by calculation from measured values (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg)
Arsenic (As) Cadmium (Cd) Beryllium (Be) Chromium (Cr) Cobalt (Co) Nickel (Ni) Thallium (Tl) Selenium (Se) Tellurium (Te) Antimony (Sb) Tin (Sn) Manganese (Mn) Copper (Cu) Lead (Pb) Vanadium (V) Zinc (Zn) Aluminium (Al) Mercury (Hg)
Regulated area: Tests
SOP č. 8 (ČSN EN 14385, ČSN EN 13211)
10 Emissions Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH)
PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAH (polycyclic aromatic hydrocarbons)
Regulated area: Tests
SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)
11 Emissions Determination of mass concentration of gaseous and volatile inorganic substances after trapping in liquid sorbent by calculation from measured values (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)
Hydrogen chloride (HCl) Chlorides (Cl-) Hydrogen fluoride (HF) Fluorides (F-) Sulphur dioxide (SO2) Sulphur oxides (SOx) Sulphuric acid (H2SO4) Ammonia (NH3) Hydrogen sulphide (H2S) Hydrogen cyanide (HCN)
Regulated area: Tests
SOP č. 9 (ČSN EN 1911, ČSN 834752-1, ČSN EN 14791, ČSN 834711-1, ČSN 834728-1, ČSN 834712-1, EPA OTM 29)
12 Automated emission measuring systems Quality assurance of automated measuring systems
Regulated area: Tests
SOP č. 11 (ČSN EN 14181, čl. 6 QAL2, čl. 8 AST)
13 Emissions Sampling of particulate pollutants with manual isokinetic control
Regulated area: Sampling
SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)
14 Emissions Sampling of organic substances by trapping on solid sorbent
Regulated area: Sampling
SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)
15 Emissions Sampling for determination of metals (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – isokinetic sampling with manual isokinetic control and absorption into liquid
Regulated area: Sampling
SOP č. 8 (ČSN EN 14385, ČSN EN 13211)
16 Emissions Sampling of persistent organic pollutants (PCDD/PCDF, PCB, PAH) - filter-condenser method
Regulated area: Sampling
SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)
17 Emissions Sampling of gaseous and volatile inorganic substances by trapping in liquid sorbent (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)
Regulated area: Sampling
SOP č. 9 (ČSN EN 1911, ČSN 834752-2, ČSN EN 14791, ČSN 834711-2, ČSN 834728-2, ČSN 834712-2, EPA OTM 29)

Reference standards (41)

EPA OTM 29
ISO 11338-1
SOP č. 1
SOP č. 10
SOP č. 11
SOP č. 2
SOP č. 4 – část A, B1
SOP č. 4 – část A, B2
SOP č. 4 – část A, B3
SOP č. 5
SOP č. 6
SOP č. 7
SOP č. 8
SOP č. 9
ČSN 834711-1
ČSN 834711-2
ČSN 834712-1
ČSN 834712-2
ČSN 834728-1
ČSN 834728-2
ČSN 834752-1
ČSN 834752-2
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13649:2002
ČSN EN 14181, čl. 6 QAL2, čl. 8 AST
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 15058
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-4+A1
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 7935
ČSN ISO 9096:1998
ČSN P CEN/TS 13649

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1568