🇨🇿 TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ BRNO, spol. s r. o. PL
Environment
TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ BRNO, spol. s r. o. is a laboratory accredited by ČIA under number 1568 (Brno, Czech Republic). Its accreditation scope covers 17 test methods in the following areas: Environment. Test objects include: Emissions, Automated emission measuring systems. Most frequently used techniques: chemiluminescence, condensation method, adsorption method, capacitive sensor, FID (flame ionisation detection).
At a glance
- Accreditation number: ČIA 1568
- Methods in scope: 17
- Types of test objects: 2
- Techniques used: 6
- City: Brno, Czech Republic
- Valid until: 13-07-2027
- Accreditation number
- 1568
- Accreditation body
- ČIA
- Address
- Zeleného 3107/50, 616 00 Brno
- City
- Brno, Czech Republic
- Division
- Laboratorium Badawcze Pomiarów Substancji Zanieczyszczających
- Valid until
- 13-07-2027
What this laboratory tests (2)
- Emissions — 16 methods
- Automated emission measuring systems — 1 method
Analytical techniques used (6)
- chemiluminescence — 1 method
- condensation method, adsorption method, capacitive sensor — 1 method
- FID (flame ionisation detection) — 1 method
- gravimetry — 1 method
- non-dispersive infrared spectroscopy — 1 method
- paramagnetic method — 1 method
Certificate information
- Certificate date
- 13.07.2022
Accreditation scope — test methods (17)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of flow velocity and volume flow rate Regulated area: Tests |
SOP č. 1 (ČSN ISO 10780, ČSN EN ISO 16911-1) | ||
| 2 | Emissions | Determination of gas moisture Regulated area: Tests |
condensation method, adsorption method, capacitive sensor | SOP č. 2 (ČSN EN 14790) | |
| 3 | Emissions | Determination of volume concentration of oxygen (O2) by automated analysers Regulated area: Tests |
paramagnetic method | SOP č. 4 – část A, B3 (ČSN EN 14789) | |
| 4 | Emissions | Determination of mass concentration of gaseous pollutants (SO2, CO) and volume concentration of CO2 by automated analysers Sulphur dioxide (SO2) Carbon monoxide (CO) Carbon dioxide (CO2) Regulated area: Tests |
non-dispersive infrared spectroscopy | SOP č. 4 – část A, B1 (ČSN ISO 7935, ČSN EN 15058) | |
| 5 | Emissions | Determination of mass concentration of gaseous pollutants (NOx) by automated analysers Nitrogen oxides (NOx) Regulated area: Tests |
chemiluminescence | SOP č. 4 – část A, B2 (ČSN EN 14792) | |
| 6 | Emissions | Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers (FID) Regulated area: Tests |
FID (flame ionisation detection) | SOP č. 5 (ČSN EN 12619) | |
| 7 | Emissions | Determination of mass concentration of organic substances (VOC) after trapping on solid sorbent by calculation from measured values Regulated area: Tests |
SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649) | ||
| 8 | Emissions | Determination of mass concentration of particulate pollutants Regulated area: Tests |
gravimetry | SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998) | |
| 9 | Emissions | Determination of mass concentration of metals by calculation from measured values (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) Arsenic (As) Cadmium (Cd) Beryllium (Be) Chromium (Cr) Cobalt (Co) Nickel (Ni) Thallium (Tl) Selenium (Se) Tellurium (Te) Antimony (Sb) Tin (Sn) Manganese (Mn) Copper (Cu) Lead (Pb) Vanadium (V) Zinc (Zn) Aluminium (Al) Mercury (Hg) Regulated area: Tests |
SOP č. 8 (ČSN EN 14385, ČSN EN 13211) | ||
| 10 | Emissions | Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAH (polycyclic aromatic hydrocarbons) Regulated area: Tests |
SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1) | ||
| 11 | Emissions | Determination of mass concentration of gaseous and volatile inorganic substances after trapping in liquid sorbent by calculation from measured values (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) Hydrogen chloride (HCl) Chlorides (Cl-) Hydrogen fluoride (HF) Fluorides (F-) Sulphur dioxide (SO2) Sulphur oxides (SOx) Sulphuric acid (H2SO4) Ammonia (NH3) Hydrogen sulphide (H2S) Hydrogen cyanide (HCN) Regulated area: Tests |
SOP č. 9 (ČSN EN 1911, ČSN 834752-1, ČSN EN 14791, ČSN 834711-1, ČSN 834728-1, ČSN 834712-1, EPA OTM 29) | ||
| 12 | Automated emission measuring systems | Quality assurance of automated measuring systems Regulated area: Tests |
SOP č. 11 (ČSN EN 14181, čl. 6 QAL2, čl. 8 AST) | ||
| 13 | Emissions | Sampling of particulate pollutants with manual isokinetic control Regulated area: Sampling |
SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998) | ||
| 14 | Emissions | Sampling of organic substances by trapping on solid sorbent Regulated area: Sampling |
SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649) | ||
| 15 | Emissions | Sampling for determination of metals (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – isokinetic sampling with manual isokinetic control and absorption into liquid Regulated area: Sampling |
SOP č. 8 (ČSN EN 14385, ČSN EN 13211) | ||
| 16 | Emissions | Sampling of persistent organic pollutants (PCDD/PCDF, PCB, PAH) - filter-condenser method Regulated area: Sampling |
SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1) | ||
| 17 | Emissions | Sampling of gaseous and volatile inorganic substances by trapping in liquid sorbent (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) Regulated area: Sampling |
SOP č. 9 (ČSN EN 1911, ČSN 834752-2, ČSN EN 14791, ČSN 834711-2, ČSN 834728-2, ČSN 834712-2, EPA OTM 29) | ||
Reference standards (41)
EPA OTM 29
ISO 11338-1
SOP č. 1
SOP č. 10
SOP č. 11
SOP č. 2
SOP č. 4 – část A, B1
SOP č. 4 – část A, B2
SOP č. 4 – část A, B3
SOP č. 5
SOP č. 6
SOP č. 7
SOP č. 8
SOP č. 9
ČSN 834711-1
ČSN 834711-2
ČSN 834712-1
ČSN 834712-2
ČSN 834728-1
ČSN 834728-2
ČSN 834752-1
ČSN 834752-2
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13649:2002
ČSN EN 14181, čl. 6 QAL2, čl. 8 AST
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 15058
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-4+A1
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 7935
ČSN ISO 9096:1998
ČSN P CEN/TS 13649