{"lab":{"_id":"69ad52a4de79e566650fd4a4","accr_number":"1568","country":"CZ","accr_body":"ČIA","address":"Zeleného 3107/50, 616 00 Brno","categories":["environment"],"city":"Brno","imported_at":"2026-03-08T10:42:44.590Z","methods_count":17,"name":"TECHNICKÉ SLUŽBY OCHRANY OVZDUŠÍ BRNO, spol. s r. o.","parse_status":"parsed","parse_version":5,"pdf_files":["1568_355_2022_CS.pdf","1568_355_2022_EN.pdf"],"scope_summary":"Pomiary stężenia substancji zanieczyszczających w emisjach, oznaczanie prędkości i objętościowego natężenia przepływu gazu w przewodzie oraz oznaczanie parametrów stanu.","search_text":"technické služby ochrany ovzduší brno, spol. s r. o. zeleného 3107/50, 616 00 brno 1568","status":"active","updated_at":"2026-03-08T14:52:13.568Z","valid_from":"","valid_until":"13-07-2027","website":"www.tesobrno.cz","location":{"type":"Point","coordinates":[16.6068,49.1951]},"map_coord":[49.208614,16.578135],"map_geo":"nominatim-street","certificate_date":"13.07.2022","certificate_no":"355/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary stężenia substancji zanieczyszczających w emisjach, oznaczanie prędkości i objętościowego natężenia przepływu gazu w przewodzie oraz oznaczanie parametrów stanu.","en":"Measurement of pollutant concentrations in emissions, determination of gas velocity and volume flow rate in ducts and determination of state variables.","zh":"排放中污染物浓度的测量，管道内气体流速和体积流量的测定以及状态参数的测定。","cs":"Měření koncentrace znečišťujících látek v emisích, stanovení rychlosti a objemového průtoku plynu v potrubí a stanovení stavových veličin."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze Pomiarów Substancji Zanieczyszczających","lab_division_cs":"Zkušební laboratoř měření znečišťujících látek","lab_division_en":"Testing Laboratory for Measurement of Pollutants","lab_division_zh":"污染物测量检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"Emise","pl":"gaz odlotowy zawierający substancje zanieczyszczające, odprowadzany w sposób zorganizowany lub uchodzący do powietrza atmosferycznego ze źródeł zanieczyszczania powietrza","en":"waste gas containing pollutants that is discharged in a controlled manner or escapes into the outdoor atmosphere from sources of air pollution","zh":"从大气污染源以受控方式排放或逸散到室外大气中的含污染物废气","cs":"odpadní plyn s obsahem znečišťujících látek, který je odváděn řízeným způsobem nebo uniká do venkovní atmosféry ze zdrojů znečišťování ovzduší"},{"abbr":"SOP","pl":"standardowa procedura operacyjna","en":"standard operating procedure","zh":"标准操作程序","cs":"standardní operační postup"},{"abbr":"VOC","pl":"lotne związki organiczne","en":"volatile organic compounds","zh":"挥发性有机物","cs":"těkavé organické látky"},{"abbr":"TOC","pl":"suma lotnych związków organicznych wyrażonych jako całkowity węgiel organiczny","en":"sum of volatile organic compounds expressed as total organic carbon","zh":"以总有机碳表示的挥发性有机物总和","cs":"suma těkavých organických látek vyjádřených jako celkový organický uhlík"},{"abbr":"PCDD/PCDF","pl":"polichlorowane dibenzodioksyny i dibenzofurany","en":"polychlorinated dibenzodioxins and dibenzofurans","zh":"多氯二苯并二噁英和二苯并呋喃","cs":"polychlorované dibenzodioxiny a dibenzofurany"},{"abbr":"PCB","pl":"polichlorowane bifenyle","en":"polychlorinated biphenyls","zh":"多氯联苯","cs":"polychlorované bifenyly"},{"abbr":"PAH","pl":"wielopierścieniowe węglowodory aromatyczne","en":"polycyclic aromatic hydrocarbons","zh":"多环芳烃","cs":"polycyklické aromatické uhlovodíky"},{"abbr":"FID","pl":"detekcja płomieniowo-jonizacyjna","en":"flame ionisation detection","zh":"火焰离子化检测","cs":"detekce ionizací plamenem"},{"abbr":"EPA OTM 29","pl":"U.S. Environmental Protection Agency (Agencja Ochrony Środowiska USA)","en":"U.S. Environmental Protection Agency","zh":"美国环境保护署（U.S. Environmental Protection Agency）","cs":"U.S. Environmental Protection Agency"},{"abbr":"AST","pl":"Roczna weryfikacja poprawności automatycznych systemów pomiarowych","en":"Annual surveillance test of automated measuring systems","zh":"自动测量系统的年度监督检验","cs":"Roční ověření správnosti automatizovaných měřicích systémů"},{"abbr":"QAL2","pl":"Kalibracja i walidacja automatycznych systemów pomiarowych","en":"Calibration and validation of automated measuring systems","zh":"自动测量系统的校准和验证","cs":"Kalibrace a ověření automatizovaných měřicích systémů"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"362f0720296c7c9128fa990c35d36fdf6960f445d86e458fda9703468bb3ed0d","source_pdf_url":"https://www.cai.cz/OA/pdf/P355_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"ba46bd55384517003e95abd3","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie prędkości przepływu i strumienia objętości","methodology_en":"Determination of flow velocity and volume flow rate","methodology_zh":"流速和体积流量的测定","methodology_cs":"Stanovení rychlosti proudění a objemového toku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prędkości przepływu i strumienia objętości","reference":"SOP č. 1 (ČSN ISO 10780, ČSN EN ISO 16911-1)","norm_bases":["SOP č. 1","ČSN ISO 10780","ČSN EN ISO 16911-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie prędkości przepływu i strumienia objętości Emise Stanovení rychlosti proudění a objemového toku SOP č. 1 (ČSN ISO 10780, ČSN EN ISO 16911-1) Emisja Oznaczanie predkosci przeplywu i strumienia objetosci Emise Stanoveni rychlosti proudeni a objemoveho toku SOP c. 1 (CSN ISO 10780, CSN EN ISO 16911-1)","search_en":"Emissions Determination of flow velocity and volume flow rate SOP č. 1 (ČSN ISO 10780, ČSN EN ISO 16911-1)","search_zh":"排放 流速和体积流量的测定 SOP č. 1 (ČSN ISO 10780, ČSN EN ISO 16911-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"897ad0288416f7f647ef1ae0","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie wilgotności gazu","methodology_en":"Determination of gas moisture","methodology_zh":"气体湿度的测定","methodology_cs":"Stanovení vlhkosti plynu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnościowy","technique_en":"condensation method, adsorption method, capacitive sensor","technique_zh":"冷凝法、吸附法、电容传感器","technique_cs":"metoda kondenzační, metoda adsorpční, kapacitní čidlo","techniques":["metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnościowy"],"techniques_en":["condensation method, adsorption method, capacitive sensor"],"techniques_zh":["冷凝法、吸附法、电容传感器"],"techniques_cs":["metoda kondenzační, metoda adsorpční, kapacitní čidlo"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności gazu\nmetoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnościowy","reference":"SOP č. 2 (ČSN EN 14790)","norm_bases":["SOP č. 2","ČSN EN 14790"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie wilgotności gazu metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnościowy Emise Stanovení vlhkosti plynu metoda kondenzační, metoda adsorpční, kapacitní čidlo SOP č. 2 (ČSN EN 14790) Emisja Oznaczanie wilgotnosci gazu metoda kondensacyjna, metoda adsorpcyjna, czujnik pojemnosciowy Emise Stanoveni vlhkosti plynu metoda kondenzacni, metoda adsorpcni, kapacitni cidlo SOP c. 2 (CSN EN 14790)","search_en":"Emissions Determination of gas moisture condensation method, adsorption method, capacitive sensor SOP č. 2 (ČSN EN 14790)","search_zh":"排放 气体湿度的测定 冷凝法、吸附法、电容传感器 SOP č. 2 (ČSN EN 14790)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"340ccbe6aa19599cf96b62b5","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia objętościowego tlenu (O2) analizatorami automatycznymi","methodology_en":"Determination of volume concentration of oxygen (O2) by automated analysers","methodology_zh":"自动分析仪测定氧（O2）的体积浓度","methodology_cs":"Stanovení objemové koncentrace kyslíku (O2) automatizovanými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda paramagnetyczna","technique_en":"paramagnetic method","technique_zh":"顺磁法","technique_cs":"paramagnetická metoda","techniques":["metoda paramagnetyczna"],"techniques_en":["paramagnetic method"],"techniques_zh":["顺磁法"],"techniques_cs":["paramagnetická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia objętościowego tlenu (O2) analizatorami automatycznymi\nmetoda paramagnetyczna","reference":"SOP č. 4 – část A, B3 (ČSN EN 14789)","norm_bases":["SOP č. 4 – část A, B3","ČSN EN 14789"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia objętościowego tlenu (O2) analizatorami automatycznymi metoda paramagnetyczna Emise Stanovení objemové koncentrace kyslíku (O2) automatizovanými analyzátory paramagnetická metoda SOP č. 4 – část A, B3 (ČSN EN 14789) Emisja Oznaczanie stezenia objetosciowego tlenu (O2) analizatorami automatycznymi metoda paramagnetyczna Emise Stanoveni objemove koncentrace kysliku (O2) automatizovanymi analyzatory paramagneticka metoda SOP c. 4 – cast A, B3 (CSN EN 14789)","search_en":"Emissions Determination of volume concentration of oxygen (O2) by automated analysers paramagnetic method SOP č. 4 – část A, B3 (ČSN EN 14789)","search_zh":"排放 自动分析仪测定氧（O2）的体积浓度 顺磁法 SOP č. 4 – část A, B3 (ČSN EN 14789)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f0972c49b3aea7306e3f283","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, CO) oraz stężenia objętościowego CO2 analizatorami automatycznymi","methodology_en":"Determination of mass concentration of gaseous pollutants (SO2, CO) and volume concentration of CO2 by automated analysers","methodology_zh":"自动分析仪测定气态污染物（SO2、CO）的质量浓度及CO2的体积浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, CO) a objemové koncentrace CO2 automatizovanými analyzátory","parameters":[{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenek węgla (CO)","range":""},{"name":"Ditlenek węgla (CO2)","range":""}],"parameters_en":[{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Carbon monoxide (CO)","range":""},{"name":"Carbon dioxide (CO2)","range":""}],"parameters_zh":[{"name":"二氧化硫（SO2）","range":""},{"name":"一氧化碳（CO）","range":""},{"name":"二氧化碳（CO2）","range":""}],"parameters_cs":[{"name":"SO2","range":""},{"name":"CO","range":""},{"name":"CO2","range":""}],"technique":"niedyspersyjna spektroskopia w podczerwieni","technique_en":"non-dispersive infrared spectroscopy","technique_zh":"非分散红外光谱法","technique_cs":"nedisperzní infračervená spektroskopie","techniques":["niedyspersyjna spektroskopia w podczerwieni"],"techniques_en":["non-dispersive infrared spectroscopy"],"techniques_zh":["非分散红外光谱法"],"techniques_cs":["nedisperzní infračervená spektroskopie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, CO) oraz stężenia objętościowego CO2 analizatorami automatycznymi\nZakres:\nDitlenek siarki (SO2)\nTlenek węgla (CO)\nDitlenek węgla (CO2)\nniedyspersyjna spektroskopia w podczerwieni","reference":"SOP č. 4 – část A, B1 (ČSN ISO 7935, ČSN EN 15058)","norm_bases":["SOP č. 4 – část A, B1","ČSN ISO 7935","ČSN EN 15058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, CO) oraz stężenia objętościowego CO2 analizatorami automatycznymi niedyspersyjna spektroskopia w podczerwieni Ditlenek siarki (SO2)  Tlenek węgla (CO)  Ditlenek węgla (CO2)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, CO) a objemové koncentrace CO2 automatizovanými analyzátory nedisperzní infračervená spektroskopie SO2  CO  CO2  SOP č. 4 – část A, B1 (ČSN ISO 7935, ČSN EN 15058) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych (SO2, CO) oraz stezenia objetosciowego CO2 analizatorami automatycznymi niedyspersyjna spektroskopia w podczerwieni Ditlenek siarki (SO2)  Tlenek wegla (CO)  Ditlenek wegla (CO2)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek (SO2, CO) a objemove koncentrace CO2 automatizovanymi analyzatory nedisperzni infracervena spektroskopie SO2  CO  CO2  SOP c. 4 – cast A, B1 (CSN ISO 7935, CSN EN 15058)","search_en":"Emissions Determination of mass concentration of gaseous pollutants (SO2, CO) and volume concentration of CO2 by automated analysers non-dispersive infrared spectroscopy Sulphur dioxide (SO2)  Carbon monoxide (CO)  Carbon dioxide (CO2)  SOP č. 4 – část A, B1 (ČSN ISO 7935, ČSN EN 15058)","search_zh":"排放 自动分析仪测定气态污染物（SO2、CO）的质量浓度及CO2的体积浓度 非分散红外光谱法 二氧化硫（SO2）  一氧化碳（CO）  二氧化碳（CO2）  SOP č. 4 – část A, B1 (ČSN ISO 7935, ČSN EN 15058)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43f23be3c88d8f3ab959a329","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (NOx) analizatorami automatycznymi","methodology_en":"Determination of mass concentration of gaseous pollutants (NOx) by automated analysers","methodology_zh":"自动分析仪测定气态污染物（NOx）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek (NOx) automatizovanými analyzátory","parameters":[{"name":"Tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"Nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NOx","range":""}],"technique":"chemiluminescencja","technique_en":"chemiluminescence","technique_zh":"化学发光法","technique_cs":"chemiluminiscence","techniques":["chemiluminescencja"],"techniques_en":["chemiluminescence"],"techniques_zh":["化学发光法"],"techniques_cs":["chemiluminiscence"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (NOx) analizatorami automatycznymi\nTlenki azotu (NOx)\nchemiluminescencja","reference":"SOP č. 4 – část A, B2 (ČSN EN 14792)","norm_bases":["SOP č. 4 – část A, B2","ČSN EN 14792"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (NOx) analizatorami automatycznymi chemiluminescencja Tlenki azotu (NOx)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek (NOx) automatizovanými analyzátory chemiluminiscence NOx  SOP č. 4 – část A, B2 (ČSN EN 14792) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych (NOx) analizatorami automatycznymi chemiluminescencja Tlenki azotu (NOx)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek (NOx) automatizovanymi analyzatory chemiluminiscence NOx  SOP c. 4 – cast A, B2 (CSN EN 14792)","search_en":"Emissions Determination of mass concentration of gaseous pollutants (NOx) by automated analysers chemiluminescence Nitrogen oxides (NOx)  SOP č. 4 – část A, B2 (ČSN EN 14792)","search_zh":"排放 自动分析仪测定气态污染物（NOx）的质量浓度 化学发光法 氮氧化物（NOx）  SOP č. 4 – část A, B2 (ČSN EN 14792)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d29896b8f476a7087c8a763d","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"6","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi (FID)","methodology_en":"Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers (FID)","methodology_zh":"自动分析仪（FID）测定以总有机碳（TOC）表示的有机物质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory (FID)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"FID (detekcja płomieniowo-jonizacyjna)","technique_en":"FID (flame ionisation detection)","technique_zh":"FID（火焰离子化检测）","technique_cs":"FID","techniques":["FID (detekcja płomieniowo-jonizacyjna)"],"techniques_en":["FID (flame ionisation detection)"],"techniques_zh":["FID（火焰离子化检测）"],"techniques_cs":["FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi (FID)\nFID (detekcja płomieniowo-jonizacyjna)","reference":"SOP č. 5 (ČSN EN 12619)","norm_bases":["SOP č. 5","ČSN EN 12619"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi (FID) FID (detekcja płomieniowo-jonizacyjna) Emise Stanovení hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory (FID) FID SOP č. 5 (ČSN EN 12619) Emisja Oznaczanie stezenia masowego substancji organicznych wyrazonych jako calkowity wegiel organiczny (TOC) analizatorami automatycznymi (FID) FID (detekcja plomieniowo-jonizacyjna) Emise Stanoveni hmotnostni koncentrace organickych latek vyjadrenych jako celkovy organicky uhlik (TOC) automatizovanymi analyzatory (FID) FID SOP c. 5 (CSN EN 12619)","search_en":"Emissions Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by automated analysers (FID) FID (flame ionisation detection) SOP č. 5 (ČSN EN 12619)","search_zh":"排放 自动分析仪（FID）测定以总有机碳（TOC）表示的有机物质量浓度 FID（火焰离子化检测） SOP č. 5 (ČSN EN 12619)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e851be28cb41c5938551bf30","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"7","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego substancji organicznych (VOC) po wychwycie na sorbencie stałym obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of organic substances (VOC) after trapping on solid sorbent by calculation from measured values","methodology_zh":"固体吸附剂捕集后由测量值计算测定有机物（VOC）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace organických látek (VOC) po záchytu na pevný sorbent výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego substancji organicznych (VOC) po wychwycie na sorbencie stałym obliczeniowo z wartości zmierzonych","reference":"SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)","norm_bases":["SOP č. 6","ČSN EN 13649:2002","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"oznaczenie laboratoryjne zapewnia podwykonawca – akredytowane laboratorium badawcze","note_en":"laboratory determination is subcontracted to an accredited testing laboratory","note_zh":"实验室测定由经认可的检测实验室分包完成","note_cs":"laboratorní stanovení je zajištěno dodavatelsky, u akreditované zkušební laboratoře","search_text":"Emisja Oznaczanie stężenia masowego substancji organicznych (VOC) po wychwycie na sorbencie stałym obliczeniowo z wartości zmierzonych Emise Stanovení hmotnostní koncentrace organických látek (VOC) po záchytu na pevný sorbent výpočtem z naměřených hodnot SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649) Emisja Oznaczanie stezenia masowego substancji organicznych (VOC) po wychwycie na sorbencie stalym obliczeniowo z wartosci zmierzonych Emise Stanoveni hmotnostni koncentrace organickych latek (VOC) po zachytu na pevny sorbent vypoctem z namerenych hodnot SOP c. 6 (CSN EN 13649:2002 CSN P CEN/TS 13649)","search_en":"Emissions Determination of mass concentration of organic substances (VOC) after trapping on solid sorbent by calculation from measured values SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)","search_zh":"排放 固体吸附剂捕集后由测量值计算测定有机物（VOC）的质量浓度 SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bf94526213bce9d61be9fa8a","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"8","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających","methodology_en":"Determination of mass concentration of particulate pollutants","methodology_zh":"颗粒污染物质量浓度的测定","methodology_cs":"Stanovení hmotnostní koncentrace tuhých znečišťujících látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"grawimetria","technique_en":"gravimetry","technique_zh":"重量法","technique_cs":"gravimetrie","techniques":["grawimetria"],"techniques_en":["gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających\ngrawimetria","reference":"SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)","norm_bases":["SOP č. 7","ČSN EN 13284-1","ČSN ISO 9096:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających grawimetria Emise Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetrie SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998) Emisja Oznaczanie stezenia masowego pylowych substancji zanieczyszczajacych grawimetria Emise Stanoveni hmotnostni koncentrace tuhych znecistujicich latek gravimetrie SOP c. 7 (CSN EN 13284-1, CSN ISO 9096:1998)","search_en":"Emissions Determination of mass concentration of particulate pollutants gravimetry SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)","search_zh":"排放 颗粒污染物质量浓度的测定 重量法 SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f7c269cd4b5cade6c5ee682b","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"9","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg)","methodology_en":"Determination of mass concentration of metals by calculation from measured values (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg)","methodology_zh":"由测量值计算测定金属（As、Cd、Be、Cr、Co、Ni、Tl、Se、Te、Sb、Sn、Mn、Cu、Pb、V、Zn、Al、Hg）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace kovů výpočtem z naměřených hodnot (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg)","parameters":[{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Selen (Se)","range":""},{"name":"Tellur (Te)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Glin (Al)","range":""},{"name":"Rtęć (Hg)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tellurium (Te)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Mercury (Hg)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""},{"name":"铍（Be）","range":""},{"name":"铬（Cr）","range":""},{"name":"钴（Co）","range":""},{"name":"镍（Ni）","range":""},{"name":"铊（Tl）","range":""},{"name":"硒（Se）","range":""},{"name":"碲（Te）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"锰（Mn）","range":""},{"name":"铜（Cu）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""},{"name":"铝（Al）","range":""},{"name":"汞（Hg）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Cd","range":""},{"name":"Be","range":""},{"name":"Cr","range":""},{"name":"Co","range":""},{"name":"Ni","range":""},{"name":"Tl","range":""},{"name":"Se","range":""},{"name":"Te","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"Mn","range":""},{"name":"Cu","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""},{"name":"Al","range":""},{"name":"Hg","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg)\nZakres:\nArsen (As)\nKadm (Cd)\nBeryl (Be)\nChrom (Cr)\nKobalt (Co)\nNikiel (Ni)\nTal (Tl)\nSelen (Se)\nTellur (Te)\nAntymon (Sb)\nCyna (Sn)\nMangan (Mn)\nMiedź (Cu)\nOłów (Pb)\nWanad (V)\nCynk (Zn)\nGlin (Al)\nRtęć (Hg)","reference":"SOP č. 8 (ČSN EN 14385, ČSN EN 13211)","norm_bases":["SOP č. 8","ČSN EN 14385","ČSN EN 13211"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"oznaczenie laboratoryjne zapewnia podwykonawca – akredytowane laboratorium badawcze","note_en":"laboratory determination is subcontracted to an accredited testing laboratory","note_zh":"实验室测定由经认可的检测实验室分包完成","note_cs":"laboratorní stanovení je zajištěno dodavatelsky, u akreditované zkušební laboratoře","search_text":"Emisja Oznaczanie stężenia masowego metali obliczeniowo z wartości zmierzonych (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) Arsen (As)  Kadm (Cd)  Beryl (Be)  Chrom (Cr)  Kobalt (Co)  Nikiel (Ni)  Tal (Tl)  Selen (Se)  Tellur (Te)  Antymon (Sb)  Cyna (Sn)  Mangan (Mn)  Miedź (Cu)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  Glin (Al)  Rtęć (Hg)  Emise Stanovení hmotnostní koncentrace kovů výpočtem z naměřených hodnot (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) As  Cd  Be  Cr  Co  Ni  Tl  Se  Te  Sb  Sn  Mn  Cu  Pb  V  Zn  Al  Hg  SOP č. 8 (ČSN EN 14385, ČSN EN 13211) Emisja Oznaczanie stezenia masowego metali obliczeniowo z wartosci zmierzonych (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) Arsen (As)  Kadm (Cd)  Beryl (Be)  Chrom (Cr)  Kobalt (Co)  Nikiel (Ni)  Tal (Tl)  Selen (Se)  Tellur (Te)  Antymon (Sb)  Cyna (Sn)  Mangan (Mn)  Miedz (Cu)  Olow (Pb)  Wanad (V)  Cynk (Zn)  Glin (Al)  Rtec (Hg)  Emise Stanoveni hmotnostni koncentrace kovu vypoctem z namerenych hodnot (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) As  Cd  Be  Cr  Co  Ni  Tl  Se  Te  Sb  Sn  Mn  Cu  Pb  V  Zn  Al  Hg  SOP c. 8 (CSN EN 14385, CSN EN 13211)","search_en":"Emissions Determination of mass concentration of metals by calculation from measured values (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) Arsenic (As)  Cadmium (Cd)  Beryllium (Be)  Chromium (Cr)  Cobalt (Co)  Nickel (Ni)  Thallium (Tl)  Selenium (Se)  Tellurium (Te)  Antimony (Sb)  Tin (Sn)  Manganese (Mn)  Copper (Cu)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  Aluminium (Al)  Mercury (Hg)  SOP č. 8 (ČSN EN 14385, ČSN EN 13211)","search_zh":"排放 由测量值计算测定金属（As、Cd、Be、Cr、Co、Ni、Tl、Se、Te、Sb、Sn、Mn、Cu、Pb、V、Zn、Al、Hg）的质量浓度 砷（As）  镉（Cd）  铍（Be）  铬（Cr）  钴（Co）  镍（Ni）  铊（Tl）  硒（Se）  碲（Te）  锑（Sb）  锡（Sn）  锰（Mn）  铜（Cu）  铅（Pb）  钒（V）  锌（Zn）  铝（Al）  汞（Hg）  SOP č. 8 (ČSN EN 14385, ČSN EN 13211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"78a3f83e0357bbb7a353088f","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"10","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych obliczeniowo z wartości zmierzonych (PCDD/PCDF, PCB, PAH)","methodology_en":"Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH)","methodology_zh":"由测量值计算测定持久性有机污染物（PCDD/PCDF、PCB、PAH）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace persistentních organických látek výpočtem z naměřených hodnot (PCDD/PCDF, PCB, PAH)","parameters":[{"name":"PCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)","range":""},{"name":"PCB (polichlorowane bifenyle)","range":""},{"name":"PAH (wielopierścieniowe węglowodory aromatyczne)","range":""}],"parameters_en":[{"name":"PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans)","range":""},{"name":"PCB (polychlorinated biphenyls)","range":""},{"name":"PAH (polycyclic aromatic hydrocarbons)","range":""}],"parameters_zh":[{"name":"PCDD/PCDF（多氯二苯并二噁英和二苯并呋喃）","range":""},{"name":"PCB（多氯联苯）","range":""},{"name":"PAH（多环芳烃）","range":""}],"parameters_cs":[{"name":"PCDD/PCDF","range":""},{"name":"PCB","range":""},{"name":"PAH","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych obliczeniowo z wartości zmierzonych (PCDD/PCDF, PCB, PAH)\nZakres:\nPCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)\nPCB (polichlorowane bifenyle)\nPAH (wielopierścieniowe węglowodory aromatyczne)","reference":"SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)","norm_bases":["SOP č. 10","ČSN EN 1948-1","ČSN EN 1948-4+A1","ISO 11338-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"oznaczenie laboratoryjne zapewnia podwykonawca – akredytowane laboratorium badawcze","note_en":"laboratory determination is subcontracted to an accredited testing laboratory","note_zh":"实验室测定由经认可的检测实验室分包完成","note_cs":"laboratorní stanovení je zajištěno dodavatelsky, u akreditované zkušební laboratoře","search_text":"Emisja Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych obliczeniowo z wartości zmierzonych (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)  PCB (polichlorowane bifenyle)  PAH (wielopierścieniowe węglowodory aromatyczne)  Emise Stanovení hmotnostní koncentrace persistentních organických látek výpočtem z naměřených hodnot (PCDD/PCDF, PCB, PAH) PCDD/PCDF  PCB  PAH  SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1) Emisja Oznaczanie stezenia masowego trwalych zanieczyszczen organicznych obliczeniowo z wartosci zmierzonych (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polichlorowane dibenzodioksyny i dibenzofurany)  PCB (polichlorowane bifenyle)  PAH (wielopierscieniowe weglowodory aromatyczne)  Emise Stanoveni hmotnostni koncentrace persistentnich organickych latek vypoctem z namerenych hodnot (PCDD/PCDF, PCB, PAH) PCDD/PCDF  PCB  PAH  SOP c. 10 (CSN EN 1948-1, CSN EN 1948-4+A1, ISO 11338-1)","search_en":"Emissions Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH) PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans)  PCB (polychlorinated biphenyls)  PAH (polycyclic aromatic hydrocarbons)  SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)","search_zh":"排放 由测量值计算测定持久性有机污染物（PCDD/PCDF、PCB、PAH）的质量浓度 PCDD/PCDF（多氯二苯并二噁英和二苯并呋喃）  PCB（多氯联苯）  PAH（多环芳烃）  SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c42797556325f8403a8695e","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"11","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych i lotnych substancji nieorganicznych po wychwycie w ciekłym sorbencie obliczeniowo z wartości zmierzonych (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)","methodology_en":"Determination of mass concentration of gaseous and volatile inorganic substances after trapping in liquid sorbent by calculation from measured values (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)","methodology_zh":"液体吸收剂捕集后由测量值计算测定气态和挥发性无机物（HCl、Cl-、HF、F-、SO2、SOx、H2SO4、NH3、H2S、HCN）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných a těkavých anorganických látek po záchytu do kapalného sorbentu výpočtem z naměřených hodnot (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)","parameters":[{"name":"Chlorowodór (HCl)","range":""},{"name":"Chlorki (Cl-)","range":""},{"name":"Fluorowodór (HF)","range":""},{"name":"Fluorki (F-)","range":""},{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki siarki (SOx)","range":""},{"name":"Kwas siarkowy (H2SO4)","range":""},{"name":"Amoniak (NH3)","range":""},{"name":"Siarkowodór (H2S)","range":""},{"name":"Cyjanowodór (HCN)","range":""}],"parameters_en":[{"name":"Hydrogen chloride (HCl)","range":""},{"name":"Chlorides (Cl-)","range":""},{"name":"Hydrogen fluoride (HF)","range":""},{"name":"Fluorides (F-)","range":""},{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Sulphur oxides (SOx)","range":""},{"name":"Sulphuric acid (H2SO4)","range":""},{"name":"Ammonia (NH3)","range":""},{"name":"Hydrogen sulphide (H2S)","range":""},{"name":"Hydrogen cyanide (HCN)","range":""}],"parameters_zh":[{"name":"氯化氢（HCl）","range":""},{"name":"氯离子（Cl-）","range":""},{"name":"氟化氢（HF）","range":""},{"name":"氟离子（F-）","range":""},{"name":"二氧化硫（SO2）","range":""},{"name":"硫氧化物（SOx）","range":""},{"name":"硫酸（H2SO4）","range":""},{"name":"氨（NH3）","range":""},{"name":"硫化氢（H2S）","range":""},{"name":"氰化氢（HCN）","range":""}],"parameters_cs":[{"name":"HCl","range":""},{"name":"Cl-","range":""},{"name":"HF","range":""},{"name":"F-","range":""},{"name":"SO2","range":""},{"name":"SOx","range":""},{"name":"H2SO4","range":""},{"name":"NH3","range":""},{"name":"H2S","range":""},{"name":"HCN","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych i lotnych substancji nieorganicznych po wychwycie w ciekłym sorbencie obliczeniowo z wartości zmierzonych (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)\nZakres:\nChlorowodór (HCl)\nChlorki (Cl-)\nFluorowodór (HF)\nFluorki (F-)\nDitlenek siarki (SO2)\nTlenki siarki (SOx)\nKwas siarkowy (H2SO4)\nAmoniak (NH3)\nSiarkowodór (H2S)\nCyjanowodór (HCN)","reference":"SOP č. 9 (ČSN EN 1911, ČSN 834752-1, ČSN EN 14791, ČSN 834711-1, ČSN 834728-1, ČSN 834712-1, EPA OTM 29)","norm_bases":["SOP č. 9","ČSN EN 1911","ČSN 834752-1","ČSN EN 14791","ČSN 834711-1","ČSN 834728-1","ČSN 834712-1","EPA OTM 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"oznaczenie laboratoryjne zapewnia podwykonawca – akredytowane laboratorium badawcze","note_en":"laboratory determination is subcontracted to an accredited testing laboratory","note_zh":"实验室测定由经认可的检测实验室分包完成","note_cs":"laboratorní stanovení je zajištěno dodavatelsky, u akreditované zkušební laboratoře","search_text":"Emisja Oznaczanie stężenia masowego gazowych i lotnych substancji nieorganicznych po wychwycie w ciekłym sorbencie obliczeniowo z wartości zmierzonych (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) Chlorowodór (HCl)  Chlorki (Cl-)  Fluorowodór (HF)  Fluorki (F-)  Ditlenek siarki (SO2)  Tlenki siarki (SOx)  Kwas siarkowy (H2SO4)  Amoniak (NH3)  Siarkowodór (H2S)  Cyjanowodór (HCN)  Emise Stanovení hmotnostní koncentrace plynných a těkavých anorganických látek po záchytu do kapalného sorbentu výpočtem z naměřených hodnot (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) HCl  Cl-  HF  F-  SO2  SOx  H2SO4  NH3  H2S  HCN  SOP č. 9 (ČSN EN 1911, ČSN 834752-1, ČSN EN 14791, ČSN 834711-1, ČSN 834728-1, ČSN 834712-1, EPA OTM 29) Emisja Oznaczanie stezenia masowego gazowych i lotnych substancji nieorganicznych po wychwycie w cieklym sorbencie obliczeniowo z wartosci zmierzonych (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) Chlorowodor (HCl)  Chlorki (Cl-)  Fluorowodor (HF)  Fluorki (F-)  Ditlenek siarki (SO2)  Tlenki siarki (SOx)  Kwas siarkowy (H2SO4)  Amoniak (NH3)  Siarkowodor (H2S)  Cyjanowodor (HCN)  Emise Stanoveni hmotnostni koncentrace plynnych a tekavych anorganickych latek po zachytu do kapalneho sorbentu vypoctem z namerenych hodnot (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) HCl  Cl-  HF  F-  SO2  SOx  H2SO4  NH3  H2S  HCN  SOP c. 9 (CSN EN 1911, CSN 834752-1, CSN EN 14791, CSN 834711-1, CSN 834728-1, CSN 834712-1, EPA OTM 29)","search_en":"Emissions Determination of mass concentration of gaseous and volatile inorganic substances after trapping in liquid sorbent by calculation from measured values (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) Hydrogen chloride (HCl)  Chlorides (Cl-)  Hydrogen fluoride (HF)  Fluorides (F-)  Sulphur dioxide (SO2)  Sulphur oxides (SOx)  Sulphuric acid (H2SO4)  Ammonia (NH3)  Hydrogen sulphide (H2S)  Hydrogen cyanide (HCN)  SOP č. 9 (ČSN EN 1911, ČSN 834752-1, ČSN EN 14791, ČSN 834711-1, ČSN 834728-1, ČSN 834712-1, EPA OTM 29)","search_zh":"排放 液体吸收剂捕集后由测量值计算测定气态和挥发性无机物（HCl、Cl-、HF、F-、SO2、SOx、H2SO4、NH3、H2S、HCN）的质量浓度 氯化氢（HCl）  氯离子（Cl-）  氟化氢（HF）  氟离子（F-）  二氧化硫（SO2）  硫氧化物（SOx）  硫酸（H2SO4）  氨（NH3）  硫化氢（H2S）  氰化氢（HCN）  SOP č. 9 (ČSN EN 1911, ČSN 834752-1, ČSN EN 14791, ČSN 834711-1, ČSN 834728-1, ČSN 834712-1, EPA OTM 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"83b5caa95dda3fdba75af73b","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"12","test_object":"Automatyczne systemy pomiarowe emisji","test_object_en":"Automated emission measuring systems","test_object_zh":"排放自动测量系统","test_object_cs":"Emisní automatizované měřicí systémy","methodology":"Zapewnienie jakości automatycznych systemów pomiarowych","methodology_en":"Quality assurance of automated measuring systems","methodology_zh":"自动测量系统的质量保证","methodology_cs":"Prokazování jakosti automatizovaných měřicích systémů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Zapewnienie jakości automatycznych systemów pomiarowych","reference":"SOP č. 11 (ČSN EN 14181, čl. 6 QAL2, čl. 8 AST)","norm_bases":["SOP č. 11","ČSN EN 14181, čl. 6 QAL2, čl. 8 AST"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Automatyczne systemy pomiarowe emisji Zapewnienie jakości automatycznych systemów pomiarowych Emisní automatizované měřicí systémy Prokazování jakosti automatizovaných měřicích systémů SOP č. 11 (ČSN EN 14181, čl. 6 QAL2, čl. 8 AST) Automatyczne systemy pomiarowe emisji Zapewnienie jakosci automatycznych systemow pomiarowych Emisni automatizovane merici systemy Prokazovani jakosti automatizovanych mericich systemu SOP c. 11 (CSN EN 14181, cl. 6 QAL2, cl. 8 AST)","search_en":"Automated emission measuring systems Quality assurance of automated measuring systems SOP č. 11 (ČSN EN 14181, čl. 6 QAL2, čl. 8 AST)","search_zh":"排放自动测量系统 自动测量系统的质量保证 SOP č. 11 (ČSN EN 14181, čl. 6 QAL2, čl. 8 AST)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f7aad1180ccb352297d71889","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek pyłowych substancji zanieczyszczających z ręczną regulacją izokinetyki","methodology_en":"Sampling of particulate pollutants with manual isokinetic control","methodology_zh":"手动等速控制的颗粒污染物采样","methodology_cs":"Odběr vzorku tuhých znečišťujících látek s manuálním řízením izokinetiky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek pyłowych substancji zanieczyszczających z ręczną regulacją izokinetyki","reference":"SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)","norm_bases":["SOP č. 7","ČSN EN 13284-1","ČSN ISO 9096:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek pyłowych substancji zanieczyszczających z ręczną regulacją izokinetyki Emise Odběr vzorku tuhých znečišťujících látek s manuálním řízením izokinetiky SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998) Emisja Pobieranie probek pylowych substancji zanieczyszczajacych z reczna regulacja izokinetyki Emise Odber vzorku tuhych znecistujicich latek s manualnim rizenim izokinetiky SOP c. 7 (CSN EN 13284-1, CSN ISO 9096:1998)","search_en":"Emissions Sampling of particulate pollutants with manual isokinetic control SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)","search_zh":"排放 手动等速控制的颗粒污染物采样 SOP č. 7 (ČSN EN 13284-1, ČSN ISO 9096:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1c4ed98d9222d0a70a9e0825","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek substancji organicznych przez wychwyt na sorbencie stałym","methodology_en":"Sampling of organic substances by trapping on solid sorbent","methodology_zh":"固体吸附剂捕集法采集有机物样品","methodology_cs":"Odběr vzorku organických látek záchytem na pevný sorbent","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek substancji organicznych przez wychwyt na sorbencie stałym","reference":"SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)","norm_bases":["SOP č. 6","ČSN EN 13649:2002","ČSN P CEN/TS 13649"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek substancji organicznych przez wychwyt na sorbencie stałym Emise Odběr vzorku organických látek záchytem na pevný sorbent SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649) Emisja Pobieranie probek substancji organicznych przez wychwyt na sorbencie stalym Emise Odber vzorku organickych latek zachytem na pevny sorbent SOP c. 6 (CSN EN 13649:2002 CSN P CEN/TS 13649)","search_en":"Emissions Sampling of organic substances by trapping on solid sorbent SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)","search_zh":"排放 固体吸附剂捕集法采集有机物样品 SOP č. 6 (ČSN EN 13649:2002 ČSN P CEN/TS 13649)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ef92a49b9a88dd9cee5dcbd7","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek do oznaczania metali (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – pobór izokinetyczny z ręczną regulacją izokinetyki i absorpcja w cieczy","methodology_en":"Sampling for determination of metals (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – isokinetic sampling with manual isokinetic control and absorption into liquid","methodology_zh":"金属（As、Cd、Be、Cr、Co、Ni、Tl、Se、Te、Sb、Sn、Mn、Cu、Pb、V、Zn、Al、Hg）测定用采样 – 手动等速控制的等速采样和液体吸收","methodology_cs":"Odběr vzorku pro stanovení kovů (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – izokinetický odběr s manuálním řízením izokinetiky a absorpce do kapaliny","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek do oznaczania metali (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – pobór izokinetyczny z ręczną regulacją izokinetyki i absorpcja w cieczy","reference":"SOP č. 8 (ČSN EN 14385, ČSN EN 13211)","norm_bases":["SOP č. 8","ČSN EN 14385","ČSN EN 13211"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek do oznaczania metali (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – pobór izokinetyczny z ręczną regulacją izokinetyki i absorpcja w cieczy Emise Odběr vzorku pro stanovení kovů (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – izokinetický odběr s manuálním řízením izokinetiky a absorpce do kapaliny SOP č. 8 (ČSN EN 14385, ČSN EN 13211) Emisja Pobieranie probek do oznaczania metali (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – pobor izokinetyczny z reczna regulacja izokinetyki i absorpcja w cieczy Emise Odber vzorku pro stanoveni kovu (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – izokineticky odber s manualnim rizenim izokinetiky a absorpce do kapaliny SOP c. 8 (CSN EN 14385, CSN EN 13211)","search_en":"Emissions Sampling for determination of metals (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg) – isokinetic sampling with manual isokinetic control and absorption into liquid SOP č. 8 (ČSN EN 14385, ČSN EN 13211)","search_zh":"排放 金属（As、Cd、Be、Cr、Co、Ni、Tl、Se、Te、Sb、Sn、Mn、Cu、Pb、V、Zn、Al、Hg）测定用采样 – 手动等速控制的等速采样和液体吸收 SOP č. 8 (ČSN EN 14385, ČSN EN 13211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"606d214fa7b87da762f50416","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek trwałych zanieczyszczeń organicznych (PCDD/PCDF, PCB, PAH) – metoda filtracyjno-kondensacyjna","methodology_en":"Sampling of persistent organic pollutants (PCDD/PCDF, PCB, PAH) - filter-condenser method","methodology_zh":"持久性有机污染物（PCDD/PCDF、PCB、PAH）采样 – 过滤冷凝法","methodology_cs":"Odběr vzorku persistentních organických látek (PCDD/PCDF, PCB, PAH) - metoda filtračně kondenzační","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek trwałych zanieczyszczeń organicznych (PCDD/PCDF, PCB, PAH) – metoda filtracyjno-kondensacyjna","reference":"SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)","norm_bases":["SOP č. 10","ČSN EN 1948-1","ČSN EN 1948-4+A1","ISO 11338-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek trwałych zanieczyszczeń organicznych (PCDD/PCDF, PCB, PAH) – metoda filtracyjno-kondensacyjna Emise Odběr vzorku persistentních organických látek (PCDD/PCDF, PCB, PAH) - metoda filtračně kondenzační SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1) Emisja Pobieranie probek trwalych zanieczyszczen organicznych (PCDD/PCDF, PCB, PAH) – metoda filtracyjno-kondensacyjna Emise Odber vzorku persistentnich organickych latek (PCDD/PCDF, PCB, PAH) - metoda filtracne kondenzacni SOP c. 10 (CSN EN 1948-1, CSN EN 1948-4+A1, ISO 11338-1)","search_en":"Emissions Sampling of persistent organic pollutants (PCDD/PCDF, PCB, PAH) - filter-condenser method SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)","search_zh":"排放 持久性有机污染物（PCDD/PCDF、PCB、PAH）采样 – 过滤冷凝法 SOP č. 10 (ČSN EN 1948-1, ČSN EN 1948-4+A1, ISO 11338-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e9a8bef074d98e89b57f9a40","lab_id":"69ad52a4de79e566650fd4a4","country":"CZ","accr_number":"1568","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek gazowych i lotnych substancji nieorganicznych przez wychwyt w ciekłym sorbencie (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)","methodology_en":"Sampling of gaseous and volatile inorganic substances by trapping in liquid sorbent (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)","methodology_zh":"液体吸收剂捕集法采集气态和挥发性无机物样品（HCl、Cl-、HF、F-、SO2、SOx、H2SO4、NH3、H2S、HCN）","methodology_cs":"Odběr vzorku plynných a těkavých anorganických látek záchytem do kapalného sorbentu (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gazowych i lotnych substancji nieorganicznych przez wychwyt w ciekłym sorbencie (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN)","reference":"SOP č. 9 (ČSN EN 1911, ČSN 834752-2, ČSN EN 14791, ČSN 834711-2, ČSN 834728-2, ČSN 834712-2, EPA OTM 29)","norm_bases":["SOP č. 9","ČSN EN 1911","ČSN 834752-2","ČSN EN 14791","ČSN 834711-2","ČSN 834728-2","ČSN 834712-2","EPA OTM 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek gazowych i lotnych substancji nieorganicznych przez wychwyt w ciekłym sorbencie (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) Emise Odběr vzorku plynných a těkavých anorganických látek záchytem do kapalného sorbentu (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) SOP č. 9 (ČSN EN 1911, ČSN 834752-2, ČSN EN 14791, ČSN 834711-2, ČSN 834728-2, ČSN 834712-2, EPA OTM 29) Emisja Pobieranie probek gazowych i lotnych substancji nieorganicznych przez wychwyt w cieklym sorbencie (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) Emise Odber vzorku plynnych a tekavych anorganickych latek zachytem do kapalneho sorbentu (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) SOP c. 9 (CSN EN 1911, CSN 834752-2, CSN EN 14791, CSN 834711-2, CSN 834728-2, CSN 834712-2, EPA OTM 29)","search_en":"Emissions Sampling of gaseous and volatile inorganic substances by trapping in liquid sorbent (HCl, Cl-, HF, F-, SO2, SOx, H2SO4, NH3, H2S, HCN) SOP č. 9 (ČSN EN 1911, ČSN 834752-2, ČSN EN 14791, ČSN 834711-2, ČSN 834728-2, ČSN 834712-2, EPA OTM 29)","search_zh":"排放 液体吸收剂捕集法采集气态和挥发性无机物样品（HCl、Cl-、HF、F-、SO2、SOx、H2SO4、NH3、H2S、HCN） SOP č. 9 (ČSN EN 1911, ČSN 834752-2, ČSN EN 14791, ČSN 834711-2, ČSN 834728-2, ČSN 834712-2, EPA OTM 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}