🇨🇿 EVECO, s.r.o. PL

ČIA 1563 • Milevsko, Czech Republic • 15 methods

Environment

EVECO, s.r.o. is a laboratory accredited by ČIA under number 1563 (Milevsko, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Emissions, Automated measuring systems. Most frequently used techniques: capacitance detector, condensation method, adsorption method, psych…, chemiluminescence, FID.

At a glance

  • Accreditation number: ČIA 1563
  • Methods in scope: 15
  • Types of test objects: 2
  • Techniques used: 6
  • City: Milevsko, Czech Republic
  • Valid until: 30-08-2027
Accreditation number
1563
Accreditation body
ČIA
Address
Sažinova 1339, 399 01 Milevsko
City
Milevsko, Czech Republic
Division
Laboratorium Badawcze EVECO, s.r.o.
Valid until
30-08-2027

What this laboratory tests (2)

Analytical techniques used (6)

Certificate information

Certificate date
10.09.2024

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of velocity and volume flow rate
Regulated area: Tests
SOP 1, část A (ČSN ISO 10780; ČSN EN ISO 16911-1)
2 Emissions Determination of water vapour
Regulated area: Tests
capacitance detector, condensation method, adsorption method, psychrometrically SOP 1, část B (ČSN EN 14790; manuál fy Bartec Ultrakust)
3 Emissions Determination of mass concentration of gaseous pollutants by automated NDIR (SO2, NOx, CO) analyzers and volumetric concentration of CO2
Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO) Carbon dioxide (CO2)
Regulated area: Tests
NDIR SOP 2 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN P CEN/TS 17405)
4 Emissions Determination of mass concentration of solid pollutants by gravimetry
Regulated area: Tests
gravimetry SOP 3, část B (ČSN EN 13284-1; ČSN ISO 9096:1998)
5 Emissions Determination of the volume concentration of oxygen by automatic analyzer
Regulated area: Tests
paramagnetic method SOP 4 (ČSN EN 14789)
6 Emissions Determination of total mass concentration of organic compounds expressed as total organic carbon (TOC) by automatic analyzers
Regulated area: Tests
FID SOP 5 (ČSN EN 12619)
7 Emissions Determination of the mass concentration of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) by calculation
Hydrogen chloride (HCl) Chlorides (Cl-) Sulphur dioxide (SO2) Sulphur oxides (SOx) Sulphuric acid (H2SO4) Ammonia (NH3) Hydrogen fluoride (HF) Fluorides (F-)
Regulated area: Tests
SOP 6, část B (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-1; ČSN 83 4752-1:1990; ČSN P CEN/TS 17340)
8 Automated measuring systems Quality assurance of automated measuring systems
Regulated area: Tests
SOP 7 (ČSN EN 14181, čl. 6, QAL2, čl. 8 AST)
9 Emissions Determination of the mass concentration of gaseous pollutants (NOx) by automatic analyzers
Nitrogen oxides (NOx)
Regulated area: Tests
chemiluminescence SOP 8 (ČSN EN 14792)
10 Emissions Determination of the mass concentration of volatile organic compounds (VOC) by calculation
benzene toluene xylenes trichloroethylene tetrachloroethylene acetone styrene
Regulated area: Tests
SOP 9, část B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)
11 Emissions Determination of mass concentration of metals by calculation
arsenic cadmium chromium cobalt copper manganese nickel lead antimony thallium vanadium zinc mercury
Regulated area: Tests
SOP 10, část B (ČSN EN 14385; ČSN EN 13211; EPA Method 29)
12 Emissions Isokinetic sampling of solid pollutants with manual and automatic isokinetic control
Regulated area: Sampling
SOP 3, část A (ČSN EN 13284-1; ČSN ISO 9096:1998)
13 Emissions Sampling of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-)
Regulated area: Sampling
SOP 6, část A (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-2; ČSN 83 4752-2:1990; ČSN P CEN/TS 17340)
14 Emissions Sampling of volatile organic compounds (VOC) by capture on a solid sorbent (benzene, toluene, xylenes, trichloroethylene, tetrachloroethylene, acetone, styrene)
Regulated area: Sampling
SOP 9, část A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)
15 Emissions Isokinetic sampling for the determination of heavy metals with manual isokinetic control and absorption into a liquid sorbent (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg)
Regulated area: Sampling
SOP 10, část A (ČSN EN 14385; ČSN EN 13211; EPA Method 29)

Reference standards (41)

EPA Method 29
SOP 1, část A
SOP 1, část B
SOP 10, část A
SOP 10, část B
SOP 2
SOP 3, část A
SOP 3, část B
SOP 4
SOP 5
SOP 6, část A
SOP 6, část B
SOP 7
SOP 8
SOP 9, část A
SOP 9, část B
manuál fy Bartec Ultrakust
ČSN 83 4728-1
ČSN 83 4728-2
ČSN 83 4752-1:1990
ČSN 83 4752-2:1990
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14181, čl. 6, QAL2, čl. 8 AST
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 15058
ČSN EN 1911
ČSN EN ISO 16017-1
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN ISO 9096:1998
ČSN P CEN/TS 13649
ČSN P CEN/TS 17340
ČSN P CEN/TS 17405

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1563