EVECO, s.r.o. is a laboratory accredited by ČIA under number 1563 (Milevsko, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Emissions, Automated measuring systems. Most frequently used techniques: capacitance detector, condensation method, adsorption method, psych…, chemiluminescence, FID.
At a glance
- Accreditation number: ČIA 1563
- Methods in scope: 15
- Types of test objects: 2
- Techniques used: 6
- City: Milevsko, Czech Republic
- Valid until: 30-08-2027
- Accreditation number
- 1563
- Accreditation body
- ČIA
- Address
- Sažinova 1339, 399 01 Milevsko
- City
- Milevsko, Czech Republic
- Division
- Laboratorium Badawcze EVECO, s.r.o.
- Valid until
- 30-08-2027
What this laboratory tests (2)
- Emissions — 14 methods
- Automated measuring systems — 1 method
Analytical techniques used (6)
- capacitance detector, condensation method, adsorption method, psychrometrically — 1 method
- chemiluminescence — 1 method
- FID — 1 method
- gravimetry — 1 method
- NDIR — 1 method
- paramagnetic method — 1 method
Certificate information
- Certificate date
- 10.09.2024
Accreditation scope — test methods (15)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of velocity and volume flow rate Regulated area: Tests |
SOP 1, část A (ČSN ISO 10780; ČSN EN ISO 16911-1) | ||
| 2 | Emissions | Determination of water vapour Regulated area: Tests |
capacitance detector, condensation method, adsorption method, psychrometrically | SOP 1, část B (ČSN EN 14790; manuál fy Bartec Ultrakust) | |
| 3 | Emissions | Determination of mass concentration of gaseous pollutants by automated NDIR (SO2, NOx, CO) analyzers and volumetric concentration of CO2 Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO) Carbon dioxide (CO2) Regulated area: Tests |
NDIR | SOP 2 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN P CEN/TS 17405) | |
| 4 | Emissions | Determination of mass concentration of solid pollutants by gravimetry Regulated area: Tests |
gravimetry | SOP 3, část B (ČSN EN 13284-1; ČSN ISO 9096:1998) | |
| 5 | Emissions | Determination of the volume concentration of oxygen by automatic analyzer Regulated area: Tests |
paramagnetic method | SOP 4 (ČSN EN 14789) | |
| 6 | Emissions | Determination of total mass concentration of organic compounds expressed as total organic carbon (TOC) by automatic analyzers Regulated area: Tests |
FID | SOP 5 (ČSN EN 12619) | |
| 7 | Emissions | Determination of the mass concentration of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) by calculation Hydrogen chloride (HCl) Chlorides (Cl-) Sulphur dioxide (SO2) Sulphur oxides (SOx) Sulphuric acid (H2SO4) Ammonia (NH3) Hydrogen fluoride (HF) Fluorides (F-) Regulated area: Tests |
SOP 6, část B (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-1; ČSN 83 4752-1:1990; ČSN P CEN/TS 17340) | ||
| 8 | Automated measuring systems | Quality assurance of automated measuring systems Regulated area: Tests |
SOP 7 (ČSN EN 14181, čl. 6, QAL2, čl. 8 AST) | ||
| 9 | Emissions | Determination of the mass concentration of gaseous pollutants (NOx) by automatic analyzers Nitrogen oxides (NOx) Regulated area: Tests |
chemiluminescence | SOP 8 (ČSN EN 14792) | |
| 10 | Emissions | Determination of the mass concentration of volatile organic compounds (VOC) by calculation benzene toluene xylenes trichloroethylene tetrachloroethylene acetone styrene Regulated area: Tests |
SOP 9, část B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) | ||
| 11 | Emissions | Determination of mass concentration of metals by calculation arsenic cadmium chromium cobalt copper manganese nickel lead antimony thallium vanadium zinc mercury Regulated area: Tests |
SOP 10, část B (ČSN EN 14385; ČSN EN 13211; EPA Method 29) | ||
| 12 | Emissions | Isokinetic sampling of solid pollutants with manual and automatic isokinetic control Regulated area: Sampling |
SOP 3, část A (ČSN EN 13284-1; ČSN ISO 9096:1998) | ||
| 13 | Emissions | Sampling of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) Regulated area: Sampling |
SOP 6, část A (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-2; ČSN 83 4752-2:1990; ČSN P CEN/TS 17340) | ||
| 14 | Emissions | Sampling of volatile organic compounds (VOC) by capture on a solid sorbent (benzene, toluene, xylenes, trichloroethylene, tetrachloroethylene, acetone, styrene) Regulated area: Sampling |
SOP 9, část A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) | ||
| 15 | Emissions | Isokinetic sampling for the determination of heavy metals with manual isokinetic control and absorption into a liquid sorbent (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg) Regulated area: Sampling |
SOP 10, část A (ČSN EN 14385; ČSN EN 13211; EPA Method 29) | ||
Reference standards (41)
EPA Method 29
SOP 1, část A
SOP 1, část B
SOP 10, část A
SOP 10, část B
SOP 2
SOP 3, část A
SOP 3, část B
SOP 4
SOP 5
SOP 6, část A
SOP 6, část B
SOP 7
SOP 8
SOP 9, část A
SOP 9, část B
manuál fy Bartec Ultrakust
ČSN 83 4728-1
ČSN 83 4728-2
ČSN 83 4752-1:1990
ČSN 83 4752-2:1990
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14181, čl. 6, QAL2, čl. 8 AST
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 15058
ČSN EN 1911
ČSN EN ISO 16017-1
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN ISO 9096:1998
ČSN P CEN/TS 13649
ČSN P CEN/TS 17340