{"lab":{"_id":"69ad52a4de79e566650fd49e","accr_number":"1563","country":"CZ","accr_body":"ČIA","address":"Sažinova 1339, 399 01 Milevsko","categories":["environment"],"city":"Milevsko","imported_at":"2026-03-08T10:42:44.590Z","methods_count":15,"name":"EVECO, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1563_461_2024_CS.pdf","1563_461_2024_EN.pdf"],"scope_summary":"Pobieranie próbek i pomiary emisji substancji zanieczyszczających ze stacjonarnych źródeł zanieczyszczania powietrza.","search_text":"eveco, s.r.o. sažinova 1339, 399 01 milevsko 1563","status":"active","updated_at":"2026-03-08T14:52:13.565Z","valid_from":"","valid_until":"30-08-2027","website":"www.evecopraha.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.evecopraha.cz","map_coord":[49.439905,14.38777],"map_geo":"nominatim-street","certificate_date":"10.09.2024","certificate_no":"461/2024","certificate_replaces":"","en_official":true,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek i pomiary emisji substancji zanieczyszczających ze stacjonarnych źródeł zanieczyszczania powietrza.","en":"Sampling and measurement of emissions of pollutants from stationary sources of air pollution.","zh":"固定大气污染源污染物排放的采样和测量。","cs":"Odběry a měření emisí znečišťujících látek ze stacionárních zdrojů znečišťování ovzduší."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze EVECO, s.r.o.","lab_division_cs":"Zkušební laboratoř EVECO, s.r.o.","lab_division_en":"Testing Laboratory EVECO, s.r.o.","lab_division_zh":"EVECO, s.r.o.检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"Emise","pl":"gaz odlotowy zawierający substancje zanieczyszczające, odprowadzany w sposób zorganizowany lub uchodzący do powietrza atmosferycznego ze źródeł zanieczyszczania powietrza","en":"Waste gas containing pollutants, which is released in a controlled way or leaks into atmosphere from air pollution sources","zh":"从大气污染源以受控方式排放或逸散到大气中的含污染物废气","cs":"odpadní plyn s obsahem znečišťujících látek, který je odváděn řízeným způsobem nebo uniká do venkovní atmosféry ze zdrojů znečišťování ovzduší"},{"abbr":"NDIR","pl":"niedyspersyjna spektrometria w podczerwieni","en":"Nondispersive Infrared Spectrometry","zh":"非分散红外光谱法","cs":"nedispersní infračervená spektrometrie"},{"abbr":"SOP","pl":"standardowa procedura operacyjna","en":"Standard Operating Procedure","zh":"标准操作程序","cs":"standardní operační postup"},{"abbr":"TOC","pl":"całkowity węgiel organiczny","en":"Total Organic Carbon","zh":"总有机碳","cs":"celkový organický uhlík"},{"abbr":"FID","pl":"detektor płomieniowo-jonizacyjny","en":"Flame Ionization Detector","zh":"火焰离子化检测器","cs":"plamenoionizační detektor"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"95a4d140d051ff280fbcf5bdd8324aa555e010fbf24654edbe99c7c011da89cb","source_pdf_url":"https://www.cai.cz/OA/pdf/P461_2024_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/P461_2024_EN.pdf"},"methods":[{"_id":"fef1744ebdabe81c71c08545","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie prędkości przepływu i strumienia objętości","methodology_en":"Determination of velocity and volume flow rate","methodology_zh":"流速和体积流量的测定","methodology_cs":"Stanovení rychlosti proudění a objemového toku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prędkości przepływu i strumienia objętości","reference":"SOP 1, část A (ČSN ISO 10780; ČSN EN ISO 16911-1)","norm_bases":["SOP 1, část A","ČSN ISO 10780","ČSN EN ISO 16911-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie prędkości przepływu i strumienia objętości Emise Stanovení rychlosti proudění a objemového toku SOP 1, část A (ČSN ISO 10780; ČSN EN ISO 16911-1) Emisja Oznaczanie predkosci przeplywu i strumienia objetosci Emise Stanoveni rychlosti proudeni a objemoveho toku SOP 1, cast A (CSN ISO 10780; CSN EN ISO 16911-1)","search_en":"Emissions Determination of velocity and volume flow rate SOP 1, část A (ČSN ISO 10780; ČSN EN ISO 16911-1)","search_zh":"排放 流速和体积流量的测定 SOP 1, část A (ČSN ISO 10780; ČSN EN ISO 16911-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"334a21d736941b86ef6d0386","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie wilgotności gazu","methodology_en":"Determination of water vapour","methodology_zh":"气体湿度（水蒸气）的测定","methodology_cs":"Stanovení vlhkosti plynu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"czujnik pojemnościowy, metoda kondensacyjna, metoda adsorpcyjna, metoda psychrometryczna","technique_en":"capacitance detector, condensation method, adsorption method, psychrometrically","technique_zh":"电容传感器、冷凝法、吸附法、干湿球法","technique_cs":"kapacitní čidlo, kondenzační metoda, adsorpční metoda, psychrometricky","techniques":["czujnik pojemnościowy, metoda kondensacyjna, metoda adsorpcyjna, metoda psychrometryczna"],"techniques_en":["capacitance detector, condensation method, adsorption method, psychrometrically"],"techniques_zh":["电容传感器、冷凝法、吸附法、干湿球法"],"techniques_cs":["kapacitní čidlo, kondenzační metoda, adsorpční metoda, psychrometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności gazu\nczujnik pojemnościowy, metoda kondensacyjna, metoda adsorpcyjna, metoda psychrometryczna","reference":"SOP 1, část B (ČSN EN 14790; manuál fy Bartec Ultrakust)","norm_bases":["SOP 1, část B","ČSN EN 14790","manuál fy Bartec Ultrakust"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie wilgotności gazu czujnik pojemnościowy, metoda kondensacyjna, metoda adsorpcyjna, metoda psychrometryczna Emise Stanovení vlhkosti plynu kapacitní čidlo, kondenzační metoda, adsorpční metoda, psychrometricky SOP 1, část B (ČSN EN 14790; manuál fy Bartec Ultrakust) Emisja Oznaczanie wilgotnosci gazu czujnik pojemnosciowy, metoda kondensacyjna, metoda adsorpcyjna, metoda psychrometryczna Emise Stanoveni vlhkosti plynu kapacitni cidlo, kondenzacni metoda, adsorpcni metoda, psychrometricky SOP 1, cast B (CSN EN 14790; manual fy Bartec Ultrakust)","search_en":"Emissions Determination of water vapour capacitance detector, condensation method, adsorption method, psychrometrically SOP 1, část B (ČSN EN 14790; manuál fy Bartec Ultrakust)","search_zh":"排放 气体湿度（水蒸气）的测定 电容传感器、冷凝法、吸附法、干湿球法 SOP 1, část B (ČSN EN 14790; manuál fy Bartec Ultrakust)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5040561bd5e8b4397b46aaf9","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających analizatorami automatycznymi NDIR (SO2, NOx, CO) oraz stężenia objętościowego CO2","methodology_en":"Determination of mass concentration of gaseous pollutants by automated NDIR (SO2, NOx, CO) analyzers and volumetric concentration of CO2","methodology_zh":"NDIR自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度及CO2的体积浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek automatizovanými analyzátory NDIR (SO2, NOx, CO) a objemové koncentrace CO2","parameters":[{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki azotu (NOx)","range":""},{"name":"Tlenek węgla (CO)","range":""},{"name":"Ditlenek węgla (CO2)","range":""}],"parameters_en":[{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Nitrogen oxides (NOx)","range":""},{"name":"Carbon monoxide (CO)","range":""},{"name":"Carbon dioxide (CO2)","range":""}],"parameters_zh":[{"name":"二氧化硫（SO2）","range":""},{"name":"氮氧化物（NOx）","range":""},{"name":"一氧化碳（CO）","range":""},{"name":"二氧化碳（CO2）","range":""}],"parameters_cs":[{"name":"SO2","range":""},{"name":"NOx","range":""},{"name":"CO","range":""},{"name":"CO2","range":""}],"technique":"NDIR (niedyspersyjna spektrometria w podczerwieni)","technique_en":"NDIR","technique_zh":"NDIR（非分散红外光谱法）","technique_cs":"NDIR","techniques":["NDIR (niedyspersyjna spektrometria w podczerwieni)"],"techniques_en":["NDIR"],"techniques_zh":["NDIR（非分散红外光谱法）"],"techniques_cs":["NDIR"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających analizatorami automatycznymi NDIR (SO2, NOx, CO) oraz stężenia objętościowego CO2\nZakres:\nDitlenek siarki (SO2)\nTlenki azotu (NOx)\nTlenek węgla (CO)\nDitlenek węgla (CO2)\nNDIR (niedyspersyjna spektrometria w podczerwieni)","reference":"SOP 2 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN P CEN/TS 17405)","norm_bases":["SOP 2","ČSN ISO 7935","ČSN ISO 10849","ČSN EN 15058","ČSN P CEN/TS 17405"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających analizatorami automatycznymi NDIR (SO2, NOx, CO) oraz stężenia objętościowego CO2 NDIR (niedyspersyjna spektrometria w podczerwieni) Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek węgla (CO)  Ditlenek węgla (CO2)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek automatizovanými analyzátory NDIR (SO2, NOx, CO) a objemové koncentrace CO2 NDIR SO2  NOx  CO  CO2  SOP 2 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN P CEN/TS 17405) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych analizatorami automatycznymi NDIR (SO2, NOx, CO) oraz stezenia objetosciowego CO2 NDIR (niedyspersyjna spektrometria w podczerwieni) Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek wegla (CO)  Ditlenek wegla (CO2)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek automatizovanymi analyzatory NDIR (SO2, NOx, CO) a objemove koncentrace CO2 NDIR SO2  NOx  CO  CO2  SOP 2 (CSN ISO 7935; CSN ISO 10849; CSN EN 15058; CSN P CEN/TS 17405)","search_en":"Emissions Determination of mass concentration of gaseous pollutants by automated NDIR (SO2, NOx, CO) analyzers and volumetric concentration of CO2 NDIR Sulphur dioxide (SO2)  Nitrogen oxides (NOx)  Carbon monoxide (CO)  Carbon dioxide (CO2)  SOP 2 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN P CEN/TS 17405)","search_zh":"排放 NDIR自动分析仪测定气态污染物（SO2、NOx、CO）的质量浓度及CO2的体积浓度 NDIR（非分散红外光谱法） 二氧化硫（SO2）  氮氧化物（NOx）  一氧化碳（CO）  二氧化碳（CO2）  SOP 2 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058; ČSN P CEN/TS 17405)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a898bd9482ea2cebd6d4c9b1","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną","methodology_en":"Determination of mass concentration of solid pollutants by gravimetry","methodology_zh":"重量法测定颗粒污染物的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną\nmetoda grawimetryczna","reference":"SOP 3, část B (ČSN EN 13284-1; ČSN ISO 9096:1998)","norm_bases":["SOP 3, část B","ČSN EN 13284-1","ČSN ISO 9096:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną metoda grawimetryczna Emise Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetricky gravimetricky SOP 3, část B (ČSN EN 13284-1; ČSN ISO 9096:1998) Emisja Oznaczanie stezenia masowego pylowych substancji zanieczyszczajacych metoda grawimetryczna metoda grawimetryczna Emise Stanoveni hmotnostni koncentrace tuhych znecistujicich latek gravimetricky gravimetricky SOP 3, cast B (CSN EN 13284-1; CSN ISO 9096:1998)","search_en":"Emissions Determination of mass concentration of solid pollutants by gravimetry gravimetry SOP 3, část B (ČSN EN 13284-1; ČSN ISO 9096:1998)","search_zh":"排放 重量法测定颗粒污染物的质量浓度 重量法 SOP 3, část B (ČSN EN 13284-1; ČSN ISO 9096:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2dd71ac63ce0896480ce1076","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia objętościowego tlenu analizatorem automatycznym","methodology_en":"Determination of the volume concentration of oxygen by automatic analyzer","methodology_zh":"自动分析仪测定氧的体积浓度","methodology_cs":"Stanovení objemové koncentrace kyslíku automatizovaným analyzátorem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda paramagnetyczna","technique_en":"paramagnetic method","technique_zh":"顺磁法","technique_cs":"paramagnetická metoda","techniques":["metoda paramagnetyczna"],"techniques_en":["paramagnetic method"],"techniques_zh":["顺磁法"],"techniques_cs":["paramagnetická metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia objętościowego tlenu analizatorem automatycznym\nmetoda paramagnetyczna","reference":"SOP 4 (ČSN EN 14789)","norm_bases":["SOP 4","ČSN EN 14789"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia objętościowego tlenu analizatorem automatycznym metoda paramagnetyczna Emise Stanovení objemové koncentrace kyslíku automatizovaným analyzátorem paramagnetická metoda SOP 4 (ČSN EN 14789) Emisja Oznaczanie stezenia objetosciowego tlenu analizatorem automatycznym metoda paramagnetyczna Emise Stanoveni objemove koncentrace kysliku automatizovanym analyzatorem paramagneticka metoda SOP 4 (CSN EN 14789)","search_en":"Emissions Determination of the volume concentration of oxygen by automatic analyzer paramagnetic method SOP 4 (ČSN EN 14789)","search_zh":"排放 自动分析仪测定氧的体积浓度 顺磁法 SOP 4 (ČSN EN 14789)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3db1c79eefd6f8a787a2b184","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"6","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi","methodology_en":"Determination of total mass concentration of organic compounds expressed as total organic carbon (TOC) by automatic analyzers","methodology_zh":"自动分析仪测定以总有机碳（TOC）表示的有机物总质量浓度","methodology_cs":"Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"FID (detektor płomieniowo-jonizacyjny)","technique_en":"FID","technique_zh":"FID（火焰离子化检测器）","technique_cs":"FID","techniques":["FID (detektor płomieniowo-jonizacyjny)"],"techniques_en":["FID"],"techniques_zh":["FID（火焰离子化检测器）"],"techniques_cs":["FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi\nFID (detektor płomieniowo-jonizacyjny)","reference":"SOP 5 (ČSN EN 12619)","norm_bases":["SOP 5","ČSN EN 12619"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie sumarycznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi FID (detektor płomieniowo-jonizacyjny) Emise Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory FID SOP 5 (ČSN EN 12619) Emisja Oznaczanie sumarycznego stezenia masowego substancji organicznych wyrazonych jako calkowity wegiel organiczny (TOC) analizatorami automatycznymi FID (detektor plomieniowo-jonizacyjny) Emise Stanoveni uhrnne hmotnostni koncentrace organickych latek vyjadrenych jako celkovy organicky uhlik (TOC) automatizovanymi analyzatory FID SOP 5 (CSN EN 12619)","search_en":"Emissions Determination of total mass concentration of organic compounds expressed as total organic carbon (TOC) by automatic analyzers FID SOP 5 (ČSN EN 12619)","search_zh":"排放 自动分析仪测定以总有机碳（TOC）表示的有机物总质量浓度 FID（火焰离子化检测器） SOP 5 (ČSN EN 12619)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7a32d62e596b05961bb7fae6","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"7","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego substancji gazowych przez absorpcję w ciekłym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) obliczeniowo","methodology_en":"Determination of the mass concentration of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) by calculation","methodology_zh":"液体吸收剂吸收法测定气态物质（HCl、Cl-、SO2、SOx、H2SO4、NH3、HF、F-）的质量浓度（计算法）","methodology_cs":"Stanovení hmotnostní koncentrace plynných látek absorpcí do kapalného sorbentu (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) dopočtem","parameters":[{"name":"Chlorowodór (HCl)","range":""},{"name":"Chlorki (Cl-)","range":""},{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki siarki (SOx)","range":""},{"name":"Kwas siarkowy (H2SO4)","range":""},{"name":"Amoniak (NH3)","range":""},{"name":"Fluorowodór (HF)","range":""},{"name":"Fluorki (F-)","range":""}],"parameters_en":[{"name":"Hydrogen chloride (HCl)","range":""},{"name":"Chlorides (Cl-)","range":""},{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Sulphur oxides (SOx)","range":""},{"name":"Sulphuric acid (H2SO4)","range":""},{"name":"Ammonia (NH3)","range":""},{"name":"Hydrogen fluoride (HF)","range":""},{"name":"Fluorides (F-)","range":""}],"parameters_zh":[{"name":"氯化氢（HCl）","range":""},{"name":"氯离子（Cl-）","range":""},{"name":"二氧化硫（SO2）","range":""},{"name":"硫氧化物（SOx）","range":""},{"name":"硫酸（H2SO4）","range":""},{"name":"氨（NH3）","range":""},{"name":"氟化氢（HF）","range":""},{"name":"氟离子（F-）","range":""}],"parameters_cs":[{"name":"HCl","range":""},{"name":"Cl-","range":""},{"name":"SO2","range":""},{"name":"SOx","range":""},{"name":"H2SO4","range":""},{"name":"NH3","range":""},{"name":"HF","range":""},{"name":"F-","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego substancji gazowych przez absorpcję w ciekłym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) obliczeniowo\nZakres:\nChlorowodór (HCl)\nChlorki (Cl-)\nDitlenek siarki (SO2)\nTlenki siarki (SOx)\nKwas siarkowy (H2SO4)\nAmoniak (NH3)\nFluorowodór (HF)\nFluorki (F-)","reference":"SOP 6, část B (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-1; ČSN 83 4752-1:1990; ČSN P CEN/TS 17340)","norm_bases":["SOP 6, část B","ČSN EN 1911","ČSN EN 14791","ČSN 83 4728-1","ČSN 83 4752-1:1990","ČSN P CEN/TS 17340"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"laboratory determination of analytes in the sample taken is carried out by an external testing provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测提供方在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisja Oznaczanie stężenia masowego substancji gazowych przez absorpcję w ciekłym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) obliczeniowo Chlorowodór (HCl)  Chlorki (Cl-)  Ditlenek siarki (SO2)  Tlenki siarki (SOx)  Kwas siarkowy (H2SO4)  Amoniak (NH3)  Fluorowodór (HF)  Fluorki (F-)  Emise Stanovení hmotnostní koncentrace plynných látek absorpcí do kapalného sorbentu (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) dopočtem HCl  Cl-  SO2  SOx  H2SO4  NH3  HF  F-  SOP 6, část B (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-1; ČSN 83 4752-1:1990; ČSN P CEN/TS 17340) Emisja Oznaczanie stezenia masowego substancji gazowych przez absorpcje w cieklym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) obliczeniowo Chlorowodor (HCl)  Chlorki (Cl-)  Ditlenek siarki (SO2)  Tlenki siarki (SOx)  Kwas siarkowy (H2SO4)  Amoniak (NH3)  Fluorowodor (HF)  Fluorki (F-)  Emise Stanoveni hmotnostni koncentrace plynnych latek absorpci do kapalneho sorbentu (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) dopoctem HCl  Cl-  SO2  SOx  H2SO4  NH3  HF  F-  SOP 6, cast B (CSN EN 1911; CSN EN 14791; CSN 83 4728-1; CSN 83 4752-1:1990; CSN P CEN/TS 17340)","search_en":"Emissions Determination of the mass concentration of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) by calculation Hydrogen chloride (HCl)  Chlorides (Cl-)  Sulphur dioxide (SO2)  Sulphur oxides (SOx)  Sulphuric acid (H2SO4)  Ammonia (NH3)  Hydrogen fluoride (HF)  Fluorides (F-)  SOP 6, část B (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-1; ČSN 83 4752-1:1990; ČSN P CEN/TS 17340)","search_zh":"排放 液体吸收剂吸收法测定气态物质（HCl、Cl-、SO2、SOx、H2SO4、NH3、HF、F-）的质量浓度（计算法） 氯化氢（HCl）  氯离子（Cl-）  二氧化硫（SO2）  硫氧化物（SOx）  硫酸（H2SO4）  氨（NH3）  氟化氢（HF）  氟离子（F-）  SOP 6, část B (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-1; ČSN 83 4752-1:1990; ČSN P CEN/TS 17340)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c8cbbfb9b9e42e499a0b3d5","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"8","test_object":"Automatyczne systemy pomiarowe","test_object_en":"Automated measuring systems","test_object_zh":"自动测量系统","test_object_cs":"Automatizované měřicí systémy","methodology":"Zapewnienie jakości automatycznych systemów pomiarowych","methodology_en":"Quality assurance of automated measuring systems","methodology_zh":"自动测量系统的质量保证","methodology_cs":"Prokazování jakosti automatizovaných měřicích systémů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Zapewnienie jakości automatycznych systemów pomiarowych","reference":"SOP 7 (ČSN EN 14181, čl. 6, QAL2, čl. 8 AST)","norm_bases":["SOP 7","ČSN EN 14181, čl. 6, QAL2, čl. 8 AST"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Automatyczne systemy pomiarowe Zapewnienie jakości automatycznych systemów pomiarowych Automatizované měřicí systémy Prokazování jakosti automatizovaných měřicích systémů SOP 7 (ČSN EN 14181, čl. 6, QAL2, čl. 8 AST) Automatyczne systemy pomiarowe Zapewnienie jakosci automatycznych systemow pomiarowych Automatizovane merici systemy Prokazovani jakosti automatizovanych mericich systemu SOP 7 (CSN EN 14181, cl. 6, QAL2, cl. 8 AST)","search_en":"Automated measuring systems Quality assurance of automated measuring systems SOP 7 (ČSN EN 14181, čl. 6, QAL2, čl. 8 AST)","search_zh":"自动测量系统 自动测量系统的质量保证 SOP 7 (ČSN EN 14181, čl. 6, QAL2, čl. 8 AST)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e18154fca08f43cc5cf9805c","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"9","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (NOx) analizatorami automatycznymi","methodology_en":"Determination of the mass concentration of gaseous pollutants (NOx) by automatic analyzers","methodology_zh":"自动分析仪测定气态污染物（NOx）的质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek (NOx) automatizovanými analyzátory","parameters":[{"name":"Tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"Nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NOx","range":""}],"technique":"chemiluminescencja","technique_en":"chemiluminescence","technique_zh":"化学发光法","technique_cs":"chemiluminiscence","techniques":["chemiluminescencja"],"techniques_en":["chemiluminescence"],"techniques_zh":["化学发光法"],"techniques_cs":["chemiluminiscence"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (NOx) analizatorami automatycznymi\nTlenki azotu (NOx)\nchemiluminescencja","reference":"SOP 8 (ČSN EN 14792)","norm_bases":["SOP 8","ČSN EN 14792"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (NOx) analizatorami automatycznymi chemiluminescencja Tlenki azotu (NOx)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek (NOx) automatizovanými analyzátory chemiluminiscence NOx  SOP 8 (ČSN EN 14792) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych (NOx) analizatorami automatycznymi chemiluminescencja Tlenki azotu (NOx)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek (NOx) automatizovanymi analyzatory chemiluminiscence NOx  SOP 8 (CSN EN 14792)","search_en":"Emissions Determination of the mass concentration of gaseous pollutants (NOx) by automatic analyzers chemiluminescence Nitrogen oxides (NOx)  SOP 8 (ČSN EN 14792)","search_zh":"排放 自动分析仪测定气态污染物（NOx）的质量浓度 化学发光法 氮氧化物（NOx）  SOP 8 (ČSN EN 14792)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b7acab0b095efcb19039036","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"10","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego lotnych związków organicznych (VOC) obliczeniowo","methodology_en":"Determination of the mass concentration of volatile organic compounds (VOC) by calculation","methodology_zh":"挥发性有机物（VOC）质量浓度的测定（计算法）","methodology_cs":"Stanovení hmotnostní koncentrace těkavých organických látek (VOC) dopočtem","parameters":[{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"ksyleny","range":""},{"name":"trichloroetylen","range":""},{"name":"tetrachloroetylen","range":""},{"name":"aceton","range":""},{"name":"styren","range":""}],"parameters_en":[{"name":"benzene","range":""},{"name":"toluene","range":""},{"name":"xylenes","range":""},{"name":"trichloroethylene","range":""},{"name":"tetrachloroethylene","range":""},{"name":"acetone","range":""},{"name":"styrene","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"二甲苯","range":""},{"name":"三氯乙烯","range":""},{"name":"四氯乙烯","range":""},{"name":"丙酮","range":""},{"name":"苯乙烯","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"xyleny","range":""},{"name":"trichloretylen","range":""},{"name":"tetrachloretylen","range":""},{"name":"aceton","range":""},{"name":"styren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego lotnych związków organicznych (VOC) obliczeniowo\nZakres:\nbenzen\ntoluen\nksyleny\ntrichloroetylen\ntetrachloroetylen\naceton\nstyren","reference":"SOP 9, část B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","norm_bases":["SOP 9, část B","ČSN P CEN/TS 13649","ČSN EN ISO 16017-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"lotne związki organiczne – benzen, toluen, ksyleny, trichloroetylen, tetrachloroetylen, aceton, styren; laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"volatile organic compounds - benzene, toluene, xylenes, trichloroethylene, tetrachloroethylene, acetone, styrene; laboratory determination of analytes in the sample taken is carried out by an external testing provider within the scope of its accreditation","note_zh":"挥发性有机物 – 苯、甲苯、二甲苯、三氯乙烯、四氯乙烯、丙酮、苯乙烯；所采样品中分析物的实验室测定由外部检测提供方在其认可范围内进行","note_cs":"těkavé organické látky - benzen, toluen, xyleny, trichloretylen, tetrachloretylen, aceton, styren; laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisja Oznaczanie stężenia masowego lotnych związków organicznych (VOC) obliczeniowo benzen  toluen  ksyleny  trichloroetylen  tetrachloroetylen  aceton  styren  Emise Stanovení hmotnostní koncentrace těkavých organických látek (VOC) dopočtem benzen  toluen  xyleny  trichloretylen  tetrachloretylen  aceton  styren  SOP 9, část B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) Emisja Oznaczanie stezenia masowego lotnych zwiazkow organicznych (VOC) obliczeniowo benzen  toluen  ksyleny  trichloroetylen  tetrachloroetylen  aceton  styren  Emise Stanoveni hmotnostni koncentrace tekavych organickych latek (VOC) dopoctem benzen  toluen  xyleny  trichloretylen  tetrachloretylen  aceton  styren  SOP 9, cast B (CSN P CEN/TS 13649; CSN EN ISO 16017-1)","search_en":"Emissions Determination of the mass concentration of volatile organic compounds (VOC) by calculation benzene  toluene  xylenes  trichloroethylene  tetrachloroethylene  acetone  styrene  SOP 9, část B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","search_zh":"排放 挥发性有机物（VOC）质量浓度的测定（计算法） 苯  甲苯  二甲苯  三氯乙烯  四氯乙烯  丙酮  苯乙烯  SOP 9, část B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dad8c40e635ca7bddca007e6","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"11","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego metali obliczeniowo","methodology_en":"Determination of mass concentration of metals by calculation","methodology_zh":"金属质量浓度的测定（计算法）","methodology_cs":"Stanovení hmotnostní koncentrace kovů dopočtem","parameters":[{"name":"arsen","range":""},{"name":"kadm","range":""},{"name":"chrom","range":""},{"name":"kobalt","range":""},{"name":"miedź","range":""},{"name":"mangan","range":""},{"name":"nikiel","range":""},{"name":"ołów","range":""},{"name":"antymon","range":""},{"name":"tal","range":""},{"name":"wanad","range":""},{"name":"cynk","range":""},{"name":"rtęć","range":""}],"parameters_en":[{"name":"arsenic","range":""},{"name":"cadmium","range":""},{"name":"chromium","range":""},{"name":"cobalt","range":""},{"name":"copper","range":""},{"name":"manganese","range":""},{"name":"nickel","range":""},{"name":"lead","range":""},{"name":"antimony","range":""},{"name":"thallium","range":""},{"name":"vanadium","range":""},{"name":"zinc","range":""},{"name":"mercury","range":""}],"parameters_zh":[{"name":"砷","range":""},{"name":"镉","range":""},{"name":"铬","range":""},{"name":"钴","range":""},{"name":"铜","range":""},{"name":"锰","range":""},{"name":"镍","range":""},{"name":"铅","range":""},{"name":"锑","range":""},{"name":"铊","range":""},{"name":"钒","range":""},{"name":"锌","range":""},{"name":"汞","range":""}],"parameters_cs":[{"name":"arsen","range":""},{"name":"kadmium","range":""},{"name":"chrom","range":""},{"name":"kobalt","range":""},{"name":"měď","range":""},{"name":"mangan","range":""},{"name":"nikl","range":""},{"name":"olovo","range":""},{"name":"antimon","range":""},{"name":"thalium","range":""},{"name":"vanad","range":""},{"name":"zinek","range":""},{"name":"rtuť","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego metali obliczeniowo\nZakres:\narsen\nkadm\nchrom\nkobalt\nmiedź\nmangan\nnikiel\nołów\nantymon\ntal\nwanad\ncynk\nrtęć","reference":"SOP 10, část B (ČSN EN 14385; ČSN EN 13211; EPA Method 29)","norm_bases":["SOP 10, část B","ČSN EN 14385","ČSN EN 13211","EPA Method 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"metale – arsen, kadm, chrom, kobalt, miedź, mangan, nikiel, ołów, antymon, tal, wanad, cynk, rtęć; laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"metals - arsenic, cadmium, chromium, cobalt, copper, manganese, nickel, lead, antimony, thallium, vanadium, zinc, mercury; laboratory determination of analytes in the sample taken is carried out by an external testing provider within the scope of its accreditation","note_zh":"金属 – 砷、镉、铬、钴、铜、锰、镍、铅、锑、铊、钒、锌、汞；所采样品中分析物的实验室测定由外部检测提供方在其认可范围内进行","note_cs":"kovy - arsen, kadmium, chrom, kobalt, měď, mangan, nikl, olovo, antimon, thalium, vanad, zinek, rtuť; laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisja Oznaczanie stężenia masowego metali obliczeniowo arsen  kadm  chrom  kobalt  miedź  mangan  nikiel  ołów  antymon  tal  wanad  cynk  rtęć  Emise Stanovení hmotnostní koncentrace kovů dopočtem arsen  kadmium  chrom  kobalt  měď  mangan  nikl  olovo  antimon  thalium  vanad  zinek  rtuť  SOP 10, část B (ČSN EN 14385; ČSN EN 13211; EPA Method 29) Emisja Oznaczanie stezenia masowego metali obliczeniowo arsen  kadm  chrom  kobalt  miedz  mangan  nikiel  olow  antymon  tal  wanad  cynk  rtec  Emise Stanoveni hmotnostni koncentrace kovu dopoctem arsen  kadmium  chrom  kobalt  med  mangan  nikl  olovo  antimon  thalium  vanad  zinek  rtut  SOP 10, cast B (CSN EN 14385; CSN EN 13211; EPA Method 29)","search_en":"Emissions Determination of mass concentration of metals by calculation arsenic  cadmium  chromium  cobalt  copper  manganese  nickel  lead  antimony  thallium  vanadium  zinc  mercury  SOP 10, část B (ČSN EN 14385; ČSN EN 13211; EPA Method 29)","search_zh":"排放 金属质量浓度的测定（计算法） 砷  镉  铬  钴  铜  锰  镍  铅  锑  铊  钒  锌  汞  SOP 10, část B (ČSN EN 14385; ČSN EN 13211; EPA Method 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7046a1f3c20183e41c51450e","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Izokinetyczne pobieranie próbek pyłowych substancji zanieczyszczających z ręczną i automatyczną regulacją izokinetyki","methodology_en":"Isokinetic sampling of solid pollutants with manual and automatic isokinetic control","methodology_zh":"手动和自动等速控制的颗粒污染物等速采样","methodology_cs":"Izokinetický odběr tuhých znečišťujících látek s manuálním a automatickým řízením izokinetiky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izokinetyczne pobieranie próbek pyłowych substancji zanieczyszczających z ręczną i automatyczną regulacją izokinetyki","reference":"SOP 3, část A (ČSN EN 13284-1; ČSN ISO 9096:1998)","norm_bases":["SOP 3, část A","ČSN EN 13284-1","ČSN ISO 9096:1998"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Izokinetyczne pobieranie próbek pyłowych substancji zanieczyszczających z ręczną i automatyczną regulacją izokinetyki Emise Izokinetický odběr tuhých znečišťujících látek s manuálním a automatickým řízením izokinetiky SOP 3, část A (ČSN EN 13284-1; ČSN ISO 9096:1998) Emisja Izokinetyczne pobieranie probek pylowych substancji zanieczyszczajacych z reczna i automatyczna regulacja izokinetyki Emise Izokineticky odber tuhych znecistujicich latek s manualnim a automatickym rizenim izokinetiky SOP 3, cast A (CSN EN 13284-1; CSN ISO 9096:1998)","search_en":"Emissions Isokinetic sampling of solid pollutants with manual and automatic isokinetic control SOP 3, část A (ČSN EN 13284-1; ČSN ISO 9096:1998)","search_zh":"排放 手动和自动等速控制的颗粒污染物等速采样 SOP 3, část A (ČSN EN 13284-1; ČSN ISO 9096:1998)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c2d625542dbeb2adebe5b84","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek substancji gazowych przez absorpcję w ciekłym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-)","methodology_en":"Sampling of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-)","methodology_zh":"液体吸收剂吸收法采集气态物质样品（HCl、Cl-、SO2、SOx、H2SO4、NH3、HF、F-）","methodology_cs":"Odběr vzorku plynných látek absorpcí do kapalného sorbentu (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek substancji gazowych przez absorpcję w ciekłym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-)","reference":"SOP 6, část A (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-2; ČSN 83 4752-2:1990; ČSN P CEN/TS 17340)","norm_bases":["SOP 6, část A","ČSN EN 1911","ČSN EN 14791","ČSN 83 4728-2","ČSN 83 4752-2:1990","ČSN P CEN/TS 17340"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek substancji gazowych przez absorpcję w ciekłym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) Emise Odběr vzorku plynných látek absorpcí do kapalného sorbentu (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) SOP 6, část A (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-2; ČSN 83 4752-2:1990; ČSN P CEN/TS 17340) Emisja Pobieranie probek substancji gazowych przez absorpcje w cieklym sorbencie (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) Emise Odber vzorku plynnych latek absorpci do kapalneho sorbentu (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) SOP 6, cast A (CSN EN 1911; CSN EN 14791; CSN 83 4728-2; CSN 83 4752-2:1990; CSN P CEN/TS 17340)","search_en":"Emissions Sampling of gaseous substances by absorption into a liquid sorbent (HCl, Cl-, SO2, SOx, H2SO4, NH3, HF, F-) SOP 6, část A (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-2; ČSN 83 4752-2:1990; ČSN P CEN/TS 17340)","search_zh":"排放 液体吸收剂吸收法采集气态物质样品（HCl、Cl-、SO2、SOx、H2SO4、NH3、HF、F-） SOP 6, část A (ČSN EN 1911; ČSN EN 14791; ČSN 83 4728-2; ČSN 83 4752-2:1990; ČSN P CEN/TS 17340)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8be4673e9ff17873cef5b357","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek lotnych związków organicznych (VOC) przez wychwyt na sorbencie stałym (benzen, toluen, ksyleny, trichloroetylen, tetrachloroetylen, aceton, styren)","methodology_en":"Sampling of volatile organic compounds (VOC) by capture on a solid sorbent (benzene, toluene, xylenes, trichloroethylene, tetrachloroethylene, acetone, styrene)","methodology_zh":"固体吸附剂捕集法采集挥发性有机物（VOC）样品（苯、甲苯、二甲苯、三氯乙烯、四氯乙烯、丙酮、苯乙烯）","methodology_cs":"Odběr vzorku těkavých organických látek (VOC) záchytem na pevný sorbent (benzen, toluen, xyleny, trichloretylen, tetrachloretylen, aceton, styren)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek lotnych związków organicznych (VOC) przez wychwyt na sorbencie stałym (benzen, toluen, ksyleny, trichloroetylen, tetrachloroetylen, aceton, styren)","reference":"SOP 9, část A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","norm_bases":["SOP 9, část A","ČSN P CEN/TS 13649","ČSN EN ISO 16017-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek lotnych związków organicznych (VOC) przez wychwyt na sorbencie stałym (benzen, toluen, ksyleny, trichloroetylen, tetrachloroetylen, aceton, styren) Emise Odběr vzorku těkavých organických látek (VOC) záchytem na pevný sorbent (benzen, toluen, xyleny, trichloretylen, tetrachloretylen, aceton, styren) SOP 9, část A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) Emisja Pobieranie probek lotnych zwiazkow organicznych (VOC) przez wychwyt na sorbencie stalym (benzen, toluen, ksyleny, trichloroetylen, tetrachloroetylen, aceton, styren) Emise Odber vzorku tekavych organickych latek (VOC) zachytem na pevny sorbent (benzen, toluen, xyleny, trichloretylen, tetrachloretylen, aceton, styren) SOP 9, cast A (CSN P CEN/TS 13649; CSN EN ISO 16017-1)","search_en":"Emissions Sampling of volatile organic compounds (VOC) by capture on a solid sorbent (benzene, toluene, xylenes, trichloroethylene, tetrachloroethylene, acetone, styrene) SOP 9, část A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","search_zh":"排放 固体吸附剂捕集法采集挥发性有机物（VOC）样品（苯、甲苯、二甲苯、三氯乙烯、四氯乙烯、丙酮、苯乙烯） SOP 9, část A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c329d8abb0de667827d01d4d","lab_id":"69ad52a4de79e566650fd49e","country":"CZ","accr_number":"1563","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Izokinetyczne pobieranie próbek do oznaczania metali ciężkich z ręczną regulacją izokinetyki i absorpcja w ciekłym sorbencie (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg)","methodology_en":"Isokinetic sampling for the determination of heavy metals with manual isokinetic control and absorption into a liquid sorbent (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg)","methodology_zh":"重金属测定用等速采样，手动等速控制并吸收于液体吸收剂（As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Th、V、Zn、Hg）","methodology_cs":"Izokinetický odběr vzorku pro stanovení těžkých kovů s manuálním řízením izokinetiky a absorpce do kapalného sorbentu (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izokinetyczne pobieranie próbek do oznaczania metali ciężkich z ręczną regulacją izokinetyki i absorpcja w ciekłym sorbencie (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg)","reference":"SOP 10, část A (ČSN EN 14385; ČSN EN 13211; EPA Method 29)","norm_bases":["SOP 10, část A","ČSN EN 14385","ČSN EN 13211","EPA Method 29"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Izokinetyczne pobieranie próbek do oznaczania metali ciężkich z ręczną regulacją izokinetyki i absorpcja w ciekłym sorbencie (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg) Emise Izokinetický odběr vzorku pro stanovení těžkých kovů s manuálním řízením izokinetiky a absorpce do kapalného sorbentu (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg) SOP 10, část A (ČSN EN 14385; ČSN EN 13211; EPA Method 29) Emisja Izokinetyczne pobieranie probek do oznaczania metali ciezkich z reczna regulacja izokinetyki i absorpcja w cieklym sorbencie (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg) Emise Izokineticky odber vzorku pro stanoveni tezkych kovu s manualnim rizenim izokinetiky a absorpce do kapalneho sorbentu (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg) SOP 10, cast A (CSN EN 14385; CSN EN 13211; EPA Method 29)","search_en":"Emissions Isokinetic sampling for the determination of heavy metals with manual isokinetic control and absorption into a liquid sorbent (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Th, V, Zn, Hg) SOP 10, část A (ČSN EN 14385; ČSN EN 13211; EPA Method 29)","search_zh":"排放 重金属测定用等速采样，手动等速控制并吸收于液体吸收剂（As、Cd、Cr、Co、Cu、Mn、Ni、Pb、Sb、Th、V、Zn、Hg） SOP 10, část A (ČSN EN 14385; ČSN EN 13211; EPA Method 29)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}