🇨🇿 Santeo Emise s.r.o. PL
Environment
Santeo Emise s.r.o. is a laboratory accredited by ČIA under number 1559 (Klatovy, Czech Republic). Its accreditation scope covers 19 test methods in the following areas: Environment. Test objects include: Emissions, Workplace air and indoor air, Workplace air, indoor and outdoor air. Most frequently used techniques: by calculation from measured values, condensation method and capacitive sensor, flame ionisation method (FID).
At a glance
- Accreditation number: ČIA 1559
- Methods in scope: 19
- Types of test objects: 3
- Techniques used: 5
- City: Klatovy, Czech Republic
- Valid until: 11-07-2027
- Accreditation number
- 1559
- Accreditation body
- ČIA
- Address
- Aretinova (budova na st.p.č. 3467 v k.ú. Klatovy), 339 01 Klatovy
- City
- Klatovy, Czech Republic
- Division
- Laboratorium Badawcze Santeo Emise
- Valid until
- 11-07-2027
What this laboratory tests (3)
- Emissions — 15 methods
- Workplace air and indoor air — 2 methods
- Workplace air, indoor and outdoor air — 2 methods
Analytical techniques used (5)
- by calculation from measured values — 7 methods
- condensation method and capacitive sensor — 1 method
- flame ionisation method (FID) — 1 method
- non-dispersive infrared spectrometry — 1 method
- paramagnetic method — 1 method
Certificate information
- Certificate date
- 11.07.2022
Accreditation scope — test methods (19)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of flow velocity and volume flow rate of gas in ducts Regulated area: Tests |
SOP 01 A (ČSN ISO 10780, ČSN EN ISO 16911-1) | ||
| 2 | Emissions | Determination of gas moisture in ducts (condensation method and capacitive sensor) Regulated area: Tests |
condensation method and capacitive sensor | SOP 01B (ČSN EN 14790) | |
| 3 | Emissions | Determination of mass concentration of gaseous components by automated analysers using non-dispersive infrared spectrometry: nitrogen oxides (NO, NO2), carbon monoxide (CO), sulphur dioxide (SO2), methane (CH4) Nitrogen monoxide (NO) Nitrogen dioxide (NO2) Carbon monoxide (CO) Sulphur dioxide (SO2) Methane (CH4) Regulated area: Tests |
non-dispersive infrared spectrometry | SOP 03 (ČSN ISO 10849, ČSN EN 15058, ČSN ISO 7935) | |
| 4 | Emissions | Determination of volume concentration of gaseous components by automated analysers using the paramagnetic method: oxygen Oxygen (O2) Regulated area: Tests |
paramagnetic method | SOP 04 (ČSN EN 14789) | |
| 5 | Emissions | Determination of mass concentration of the sum of organic substances expressed as total organic carbon (TOC) by automated analysers using the flame ionisation method Regulated area: Tests |
flame ionisation method (FID) | SOP 05 (ČSN EN 12619) | |
| 6 | Emissions | Determination of mass concentration of particulate pollutants and respirable fibres by calculation from measured values Regulated area: Tests |
by calculation from measured values | SOP 06 (ČSN EN 13284-1, ISO 10397) | |
| 7 | Emissions | Determination of mass concentration of metals by calculation from measured values (As, Cd, total Cr, Cr6+, Co, Cu, Mn, Ni, Zn, Pb, Sb, Tl, V, Hg) Arsenic (As) Cadmium (Cd) Total chromium (Cr) Hexavalent chromium (Cr6+) Cobalt (Co) Copper (Cu) Manganese (Mn) Nickel (Ni) Zinc (Zn) Lead (Pb) Antimony (Sb) Thallium (Tl) Vanadium (V) Mercury (Hg) Regulated area: Tests |
by calculation from measured values | SOP 07 (ČSN EN 14385, ČSN EN 13211) | |
| 8 | Emissions | Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAU) PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAU (polycyclic aromatic hydrocarbons) Regulated area: Tests |
by calculation from measured values | SOP 08 (ČSN EN 1948-3, ČSN EN 1948-4+A1) | |
| 9 | Emissions | Determination of mass concentration of gases and vapours by calculation from measured values (hydrogen chloride and volatile inorganic chlorine compounds, hydrogen fluoride and volatile inorganic fluorine compounds) Regulated area: Tests |
by calculation from measured values | SOP 09 (ČSN EN 1911, ČSN 83 4752-3:1990) | |
| 10 | Emissions | Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values Regulated area: Tests |
by calculation from measured values | SOP 10 (ČSN P CEN/TS 13649) | |
| 11 | Workplace air and indoor air | Determination of mass concentration of aerosols, gases and vapours by calculation from measured values Regulated area: Tests |
by calculation from measured values | SOP 11 (Nařízení vlády 361/2007 Sb., ČSN EN 689+AC) | |
| 12 | Workplace air, indoor and outdoor air | Determination of mass concentration of inhalable and respirable fractions of airborne dust and of respirable fibres by calculation from measured values Regulated area: Tests |
by calculation from measured values | SOP 12 (Nařízení vlády 361/2007 Sb., ČSN EN 481, ČSN EN 689+AC, ČSN EN ISO 16000-1, ČSN EN ISO 16000-7) | |
| 13 | Emissions | Sampling of particulate pollutants and respirable fibres – isokinetic sampling with automatic isokinetic control Regulated area: Sampling |
SOP V01 (ČSN EN 13284-1, ISO 10397) | ||
| 14 | Emissions | Sampling of metal aerosol: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Hg – isokinetic sampling with automatic isokinetic control and absorption into liquid Regulated area: Sampling |
SOP V02 (ČSN EN 14385, ČSN EN 13211) | ||
| 15 | Emissions | Sampling of gases and vapours by absorption into liquid: (hydrogen chloride and volatile inorganic chlorine compounds, hydrogen fluoride and volatile inorganic fluorine compounds) Regulated area: Sampling |
SOP V03 (ČSN EN 1911-1, ČSN 83 4752-1:1990 ČSN 83 4752-2:1990) | ||
| 16 | Emissions | Sampling of persistent organic pollutants (PCDD/PCDF, PCB, PAH) by the filter-condenser method Regulated area: Sampling |
SOP V04 (ČSN EN 1948-1 ČSN EN 1948-4+A1) | ||
| 17 | Emissions | Sampling of organic substances by trapping on solid sorbent (VOCs) Regulated area: Sampling |
SOP V05 (ČSN P CEN/TS 13649) | ||
| 18 | Workplace air and indoor air | Sampling of aerosols, gases and vapours by sorption on solid sorbent or trapping on filter medium Regulated area: Sampling |
SOP V06 (Nařízení vlády 361/2007 Sb., ČSN EN 689+AC) | ||
| 19 | Workplace air, indoor and outdoor air | Sampling of dust, aerosols and respirable fibres by trapping on filter Regulated area: Sampling |
SOP V07 (Nařízení vlády 361/2007 Sb., ČSN EN 481, ČSN EN 689+AC, ČSN EN ISO 16000-1, ČSN EN ISO 16000-7) | ||
Reference standards (45)
ISO 10397
Nařízení vlády 361/2007 Sb.
SOP 01 A
SOP 01B
SOP 03
SOP 04
SOP 05
SOP 06
SOP 07
SOP 08
SOP 09
SOP 10
SOP 11
SOP 12
SOP V01
SOP V02
SOP V03
SOP V04
SOP V05
SOP V06
SOP V07
ČSN 83 4752-1:1990
ČSN 83 4752-2:1990
ČSN 83 4752-3:1990
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN EN 1911-1
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN 481
ČSN EN 689+AC
ČSN EN ISO 16000-1
ČSN EN ISO 16000-7
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 13649