🇨🇿 Santeo Emise s.r.o. PL

ČIA 1559 • Klatovy, Czech Republic • 19 methods

Environment

Santeo Emise s.r.o. is a laboratory accredited by ČIA under number 1559 (Klatovy, Czech Republic). Its accreditation scope covers 19 test methods in the following areas: Environment. Test objects include: Emissions, Workplace air and indoor air, Workplace air, indoor and outdoor air. Most frequently used techniques: by calculation from measured values, condensation method and capacitive sensor, flame ionisation method (FID).

At a glance

  • Accreditation number: ČIA 1559
  • Methods in scope: 19
  • Types of test objects: 3
  • Techniques used: 5
  • City: Klatovy, Czech Republic
  • Valid until: 11-07-2027
Accreditation number
1559
Accreditation body
ČIA
Address
Aretinova (budova na st.p.č. 3467 v k.ú. Klatovy), 339 01 Klatovy
City
Klatovy, Czech Republic
Division
Laboratorium Badawcze Santeo Emise
Valid until
11-07-2027

What this laboratory tests (3)

Analytical techniques used (5)

Certificate information

Certificate date
11.07.2022

Accreditation scope — test methods (19)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of flow velocity and volume flow rate of gas in ducts
Regulated area: Tests
SOP 01 A (ČSN ISO 10780, ČSN EN ISO 16911-1)
2 Emissions Determination of gas moisture in ducts (condensation method and capacitive sensor)
Regulated area: Tests
condensation method and capacitive sensor SOP 01B (ČSN EN 14790)
3 Emissions Determination of mass concentration of gaseous components by automated analysers using non-dispersive infrared spectrometry: nitrogen oxides (NO, NO2), carbon monoxide (CO), sulphur dioxide (SO2), methane (CH4)
Nitrogen monoxide (NO) Nitrogen dioxide (NO2) Carbon monoxide (CO) Sulphur dioxide (SO2) Methane (CH4)
Regulated area: Tests
non-dispersive infrared spectrometry SOP 03 (ČSN ISO 10849, ČSN EN 15058, ČSN ISO 7935)
4 Emissions Determination of volume concentration of gaseous components by automated analysers using the paramagnetic method: oxygen
Oxygen (O2)
Regulated area: Tests
paramagnetic method SOP 04 (ČSN EN 14789)
5 Emissions Determination of mass concentration of the sum of organic substances expressed as total organic carbon (TOC) by automated analysers using the flame ionisation method
Regulated area: Tests
flame ionisation method (FID) SOP 05 (ČSN EN 12619)
6 Emissions Determination of mass concentration of particulate pollutants and respirable fibres by calculation from measured values
Regulated area: Tests
by calculation from measured values SOP 06 (ČSN EN 13284-1, ISO 10397)
7 Emissions Determination of mass concentration of metals by calculation from measured values (As, Cd, total Cr, Cr6+, Co, Cu, Mn, Ni, Zn, Pb, Sb, Tl, V, Hg)
Arsenic (As) Cadmium (Cd) Total chromium (Cr) Hexavalent chromium (Cr6+) Cobalt (Co) Copper (Cu) Manganese (Mn) Nickel (Ni) Zinc (Zn) Lead (Pb) Antimony (Sb) Thallium (Tl) Vanadium (V) Mercury (Hg)
Regulated area: Tests
by calculation from measured values SOP 07 (ČSN EN 14385, ČSN EN 13211)
8 Emissions Determination of mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAU)
PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAU (polycyclic aromatic hydrocarbons)
Regulated area: Tests
by calculation from measured values SOP 08 (ČSN EN 1948-3, ČSN EN 1948-4+A1)
9 Emissions Determination of mass concentration of gases and vapours by calculation from measured values (hydrogen chloride and volatile inorganic chlorine compounds, hydrogen fluoride and volatile inorganic fluorine compounds)
Regulated area: Tests
by calculation from measured values SOP 09 (ČSN EN 1911, ČSN 83 4752-3:1990)
10 Emissions Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values
Regulated area: Tests
by calculation from measured values SOP 10 (ČSN P CEN/TS 13649)
11 Workplace air and indoor air Determination of mass concentration of aerosols, gases and vapours by calculation from measured values
Regulated area: Tests
by calculation from measured values SOP 11 (Nařízení vlády 361/2007 Sb., ČSN EN 689+AC)
12 Workplace air, indoor and outdoor air Determination of mass concentration of inhalable and respirable fractions of airborne dust and of respirable fibres by calculation from measured values
Regulated area: Tests
by calculation from measured values SOP 12 (Nařízení vlády 361/2007 Sb., ČSN EN 481, ČSN EN 689+AC, ČSN EN ISO 16000-1, ČSN EN ISO 16000-7)
13 Emissions Sampling of particulate pollutants and respirable fibres – isokinetic sampling with automatic isokinetic control
Regulated area: Sampling
SOP V01 (ČSN EN 13284-1, ISO 10397)
14 Emissions Sampling of metal aerosol: As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Hg – isokinetic sampling with automatic isokinetic control and absorption into liquid
Regulated area: Sampling
SOP V02 (ČSN EN 14385, ČSN EN 13211)
15 Emissions Sampling of gases and vapours by absorption into liquid: (hydrogen chloride and volatile inorganic chlorine compounds, hydrogen fluoride and volatile inorganic fluorine compounds)
Regulated area: Sampling
SOP V03 (ČSN EN 1911-1, ČSN 83 4752-1:1990 ČSN 83 4752-2:1990)
16 Emissions Sampling of persistent organic pollutants (PCDD/PCDF, PCB, PAH) by the filter-condenser method
Regulated area: Sampling
SOP V04 (ČSN EN 1948-1 ČSN EN 1948-4+A1)
17 Emissions Sampling of organic substances by trapping on solid sorbent (VOCs)
Regulated area: Sampling
SOP V05 (ČSN P CEN/TS 13649)
18 Workplace air and indoor air Sampling of aerosols, gases and vapours by sorption on solid sorbent or trapping on filter medium
Regulated area: Sampling
SOP V06 (Nařízení vlády 361/2007 Sb., ČSN EN 689+AC)
19 Workplace air, indoor and outdoor air Sampling of dust, aerosols and respirable fibres by trapping on filter
Regulated area: Sampling
SOP V07 (Nařízení vlády 361/2007 Sb., ČSN EN 481, ČSN EN 689+AC, ČSN EN ISO 16000-1, ČSN EN ISO 16000-7)

Reference standards (45)

ISO 10397
Nařízení vlády 361/2007 Sb.
SOP 01 A
SOP 01B
SOP 03
SOP 04
SOP 05
SOP 06
SOP 07
SOP 08
SOP 09
SOP 10
SOP 11
SOP 12
SOP V01
SOP V02
SOP V03
SOP V04
SOP V05
SOP V06
SOP V07
ČSN 83 4752-1:1990
ČSN 83 4752-2:1990
ČSN 83 4752-3:1990
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN EN 1911-1
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN 481
ČSN EN 689+AC
ČSN EN ISO 16000-1
ČSN EN ISO 16000-7
ČSN EN ISO 16911-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 13649

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1559