🇨🇿 Ekologická laboratoř PEAL s.r.o. PL
Water & wastewaterEnvironmentMicrobiology
Ekologická laboratoř PEAL s.r.o. is a laboratory accredited by ČIA under number 1553 (Praha 4 - Libuš, Czech Republic). Its accreditation scope covers 104 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Water, leachate, Emissions, Water, Earth, waste, sludge.
At a glance
- Accreditation number: ČIA 1553
- Methods in scope: 104
- Types of test objects: 40
- City: Praha 4 - Libuš, Czech Republic
- Valid until: 13-01-2027
- Accreditation number
- 1553
- Accreditation body
- ČIA
- Address
- U Vodojemu 914/15, 142 00 Praha 4 - Libuš
- City
- Praha 4 - Libuš, Czech Republic
- Division
- Laboratorium Ekologiczne PEAL s.r.o.
- Valid until
- 13-01-2027
What this laboratory tests (40)
- Water, leachate — 18 methods
- Emissions — 12 methods
- Water — 12 methods
- Earth, waste, sludge — 6 methods
- Workplace air, indoor air of buildings — 6 methods
- Workplace air, indoor air of buildings, outdoor air — 5 methods
- Swabs — 3 methods
- Water – drinking, bottled, bathing — 3 methods
- Drinking and surface water — 2 methods
- Emissions – absorption solutions — 2 methods
- Emissions – absorption solutions and/or filters, workplace air – filters, indoor air of buildings – filters — 2 methods
- Water – drinking, bathing — 2 methods
- Water – drinking, hot — 2 methods
- Water – surface, bathing — 2 methods
- Water – surface, waste — 2 methods
- and 25 more
Certificate information
- Certificate date
- 20.11.2025
Accreditation scope — test methods (104)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Water, leachate | Determination of pH by potentiometry Regulated area: Tests |
SOP pH-01 (ČSN ISO 10523) | ||
| 2 | Water | Determination of temperature Regulated area: Tests |
SOP T-01 (ČSN 75 7342) | ||
| 3 | Water, leachate | Determination of electrical conductivity Regulated area: Tests |
SOP EK-01 (ČSN EN 27888) | ||
| 4 | Water – drinking, bathing | Determination of oxidation-reduction potential (ORP) by potentiometry Regulated area: Tests |
SOP Redox-01 (ČSN 75 7367) | ||
| 5 | Water | Determination of dissolved oxygen with a membrane probe by electrochemistry Regulated area: Tests |
SOP O2-01 (ČSN EN ISO 5814) | ||
| 6 | Water – surface, waste | Determination of biochemical oxygen demand after n days (BODn) with a membrane probe by electrochemistry Regulated area: Tests |
SOP BSK5-01 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN EN ISO 5814) | ||
| 7 | Water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP ZÁKAL-01 (ČSN EN ISO 7027-1) | ||
| 8 | Water – drinking, hot | Determination of colour visually Regulated area: Tests |
SOP BARVA-01 (ČSN EN ISO 7887) | ||
| 9 | Water – drinking, hot, bottled | Indicative sensory analysis – determination of odour and taste Regulated area: Tests |
SOP SENZOR-01 (ČSN 75 7340; ČSN EN 1622) | ||
| 10 | Water – bathing | Indicative sensory analysis – determination of appearance, transparency, colour and odour Regulated area: Tests |
SOP SENZOR-02 (ČSN 75 7340) | ||
| 11 | Water | Determination of total solids dried and ignited and loss on ignition by gravimetry Regulated area: Tests |
SOP VL-01 (ČSN 75 7346) | ||
| 12 | Water, leachate | Determination of dissolved solids dried and ignited and loss on ignition by gravimetry Regulated area: Tests |
SOP RL-01 (ČSN 75 7346) | ||
| 13 | Water | Determination of suspended solids dried and ignited and loss on ignition by gravimetry Regulated area: Tests |
SOP NL-01 (ČSN EN 872) | ||
| 14 | Water | Determination of dissolved inorganic salts (RAS) by gravimetry Regulated area: Tests |
SOP RAS-01 (ČSN 75 7347) | ||
| 15 | Earth, waste, sludge | Determination of dry matter, residue on ignition and loss on ignition by gravimetry Regulated area: Tests |
SOP SUŠINA-01 (ČSN EN 15934; ČSN EN 12880) | ||
| 16 | Water, leachate | Determination of fats and oils by gravimetry Regulated area: Tests |
SOP TUKY-01 (ČSN 75 7509) | ||
| 17 | Water, leachate, waste | Determination of extractable substances (ELGR) by gravimetry Regulated area: Tests |
SOP ELGR-01 (ČSN 75 7508) | ||
| 18 | Water | Determination of acid neutralising capacity KNK4.5 and KNK8.3 by titration and of hydrogen carbonates and the Langelier saturation index by calculation from measured values Regulated area: Tests |
SOP KNK-01 (ČSN EN ISO 9963-1) | ||
| 19 | Water | Determination of base neutralising capacity ZNK4.5 and ZNK8.3 by titration and of total, free and aggressive carbon dioxide by calculation from measured values Regulated area: Tests |
SOP ZNK-01 (ČSN 75 7372, ČSN EN ISO 9963-1; ČSN 75 7573) | ||
| 20 | Water, leachate | Determination of the sum of calcium and magnesium by titration Regulated area: Tests |
SOP TVRD-01 (ČSN ISO 6059) | ||
| 21 | Water, leachate | Determination of calcium by titration and of magnesium by calculation from measured values Regulated area: Tests |
SOP CaMg-01 (ČSN ISO 6058; ČSN ISO 6059) | ||
| 22 | Water, leachate | Determination of chlorides by argentometric titration Regulated area: Tests |
SOP Cl-01 (ČSN ISO 9297) | ||
| 23 | Water – surface, waste | Determination of ammonium ions (NH4+) by titration after distillation and of ammoniacal nitrogen (N-NH4+) by calculation from measured values Regulated area: Tests |
SOP NH4TITR-01 (ČSN ISO 5664) | ||
| 24 | Water, leachate | Determination of phosphates (PO43-) and total phosphorus by spectrophotometry and of phosphate phosphorus (P-PO43-) and phosphorus pentoxide from phosphates (P2O5 - PO43-) by calculation from measured values Regulated area: Tests |
SOP PO4-01 (ČSN EN ISO 6878, kap. 4 a 7) | ||
| 25 | Water, leachate | Determination of nitrites (NO2-) by spectrophotometry and of nitrite nitrogen (N-NO2-) by calculation from measured values Regulated area: Tests |
SOP NO2-01 (ČSN EN 26777) | ||
| 26 | Water, leachate | Determination of ammonium ions (NH4+) by spectrophotometry and of ammoniacal nitrogen (N-NH4+) by calculation from measured values Regulated area: Tests |
SOP NH4-02 (ČSN ISO 7150-1) | ||
| 27 | Water – drinking, bathing | Determination of ozone by spectrophotometry – Hach commercial analytical kit Regulated area: Tests |
SOP OZON-01 (Manuál Hach, metoda 8311) | ||
| 28 | Water | Determination of nitrates (NO3-) by UV spectrophotometry and of nitrate nitrogen (N-NO3-) by calculation from measured values Regulated area: Tests |
SOP NO3UV – 01 (Horáková a kol., Chemické a fyzikální metody analýzy vod, SNTL Praha 1986, kap. 2.24.2.) | ||
| 29 | Water – drinking, hot, waste, bathing | Determination of free and total chlorine by spectrophotometry and of combined chlorine by calculation from measured values – Hach commercial analytical kit Regulated area: Tests |
SOP Cl2-terén (ČSN EN ISO 7393-2, Manuál Hach, metoda 8021 a 8167) | ||
| 30 | Water – surface, bathing | Determination of chlorophyll a by spectrophotometry Regulated area: Tests |
SOP CHLF-01 (ČSN ISO 10260) | ||
| 31 | Water, leachate | Determination of chemical oxygen demand by potassium dichromate (COD-Cr) by spectrophotometry – Hach commercial analytical kit Regulated area: Tests |
SOP CHSKCr-01 (ČSN ISO 15705, Manuál Hach, metoda LCl 400 a LCl 500) | ||
| 32 | Water, leachate | Determination of monohydric phenols by spectrophotometry after distillation Regulated area: Tests |
SOP FEN-01 (ČSN ISO 6439) | ||
| 33 | Water, leachate | Determination of anionic surfactants by spectrophotometry Regulated area: Tests |
SOP AT-01 (ČSN EN 903) | ||
| 34 | Water, leachate | Determination of sulphates by turbidimetry Regulated area: Tests |
SOP SO4-01 (US EPA 375.4) | ||
| 35 | Water – drinking, hot, bathing | Determination of chlorine dioxide by spectrophotometry – Hach commercial analytical kit Regulated area: Tests |
SOP CLO2-01 (Manuál Hach, metoda HPT240) | ||
| 36 | Workplace air, indoor air of buildings | Determination of trichloramine by spectrophotometry Regulated area: Tests |
SOP OV20 (Hery M. a kol. Ann. Occup. Hyg. 39, 427-439:1995) | ||
| 37 | Workplace air – solid sorbents | Determination of the mass concentration of hydrogen peroxide by spectrophotometry Regulated area: Tests |
SOP OV10 (OSHA VI-6, NV č. 361/2007 Sb.) | ||
| 38 | Water, leachate | Determination of total nitrogen by chemiluminescence and of organic and inorganic nitrogen by calculation from measured values Regulated area: Tests |
SOP Dusík-02 (ČSN EN 12260:2004) | ||
| 39 | Water, leachate | Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) with an analyser – IR detection technique Regulated area: Tests |
SOP TOC-01 (ČSN EN 1484) | ||
| 40 | Water, leachate | Determination of metals by AAS – electrothermal atomisation technique Arsenic (As) Barium (Ba) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Molybdenum (Mo) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Vanadium (V) Regulated area: Tests |
SOP AAS-KYVETA-W (ČSN EN ISO 15586; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2) | ||
| 41 | Earth, waste, sludge | Determination of metals by AAS – electrothermal atomisation technique Arsenic (As) Barium (Ba) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Molybdenum (Mo) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Vanadium (V) Regulated area: Tests |
SOP AAS-KYVETA-S (ČSN EN ISO 15586; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2; ČSN EN 13346:2001) | ||
| 42 | Emissions – absorption solutions and/or filters, workplace air – filters, indoor air of buildings – filters | Determination of metals by AAS – electrothermal atomisation technique Arsenic (As) Barium (Ba) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Molybdenum (Mo) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Vanadium (V) Regulated area: Tests |
SOP AAS-KYVETA-A (ČSN EN ISO 21832; NIOSH Method 7301; ČSN EN 14385) | ||
| 43 | Water, leachate | Determination of metals by AAS – flame technique Silver (Ag) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Sodium (Na) Nickel (Ni) Lead (Pb) Zinc (Zn) Regulated area: Tests |
SOP AAS-PLAMEN-W (ČSN ISO 8288; ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN 75 7400; ČSN EN 1233; ČSN ISO 7980; ČSN 75 7385; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2) | ||
| 44 | Earth, waste, sludge | Determination of metals by AAS – flame technique Silver (Ag) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Sodium (Na) Nickel (Ni) Lead (Pb) Zinc (Zn) Regulated area: Tests |
SOP AAS-PLAMEN-S (ČSN ISO 8288; ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN 75 7400; ČSN EN 1233; ČSN ISO 7980; ČSN 75 7385; ČSN P CEN/TS 16188:2012; ČSN EN 16174:2013; ČSN EN 16173; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2; ČSN EN 13346:2001) | ||
| 45 | Emissions – absorption solutions and/or filters, workplace air – filters, indoor air of buildings – filters | Determination of metals by AAS – flame technique Silver (Ag) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Sodium (Na) Nickel (Ni) Lead (Pb) Zinc (Zn) Regulated area: Tests |
SOP AAS-PLAMEN-A (ČSN EN 14385; ČSN EN ISO 21832; NIOSH Method 7301) | ||
| 46 | Water, leachate, earth, waste, sludge, emissions – absorption solutions and/or filters, workplace air – filters, indoor air of buildings – filters | Determination of mercury with a dedicated AMA analyser Regulated area: Tests |
SOP Hg-01 (ČSN 75 7440; ČSN EN 13211) | ||
| 47 | Water | Determination of volatile organic compounds (VOC) by gas chromatography (GC/ECD+FID) benzene toluene ethylbenzene xylene (sum of all isomers) 1,2-dichloroethane cis-1,2-dichloroethene tetrachloroethene trichloroethene tetrachloromethane trichloromethane tribromomethane bromodichloromethane dibromochloromethane chlorobenzene o-dichlorobenzene m-dichlorobenzene p-dichlorobenzene Regulated area: Tests |
SOP TOL-02 (ČSN EN ISO 10301; ČSN ISO 11423-2; ČSN EN ISO 15680) | ||
| 48 | Earth, waste, sludge | Determination of volatile organic compounds (VOC) by gas chromatography (GC/ECD+FID) benzene toluene ethylbenzene xylene (sum of all isomers) tetrachloroethene trichloroethene Regulated area: Tests |
SOP TOL-02 (ČSN EN ISO 10301; ČSN ISO 11423-2; ČSN EN ISO 15009) | ||
| 49 | Emissions, workplace air, indoor air of buildings – solid sorbents | Determination of the mass concentration of individual volatile organic compounds (VOC) by gas chromatography (GC/ECD+FID) benzene toluene ethylbenzene xylenes (sum of isomers) trichloroethene tetrachloroethene ethyl acetate butyl acetate ethanol 2-propanol 1-butanol 2-butanol 2-methyl-2-propanol acetone 2-butanone 2-methoxyethanol 2-ethoxyethanol 2-butoxyethanol Regulated area: Tests |
SOP OV08 (ČSN P CEN/TS 13649; ČSN EN 14662-2; NIOSH Method 1501; NIOSH Method 1450; NIOSH Method 1457; NIOSH Method 1401; NIOSH Method 1400; NIOSH Method 1022; NIOSH Method 1003; NIOSH Method 1300; NIOSH Method 1403; Vyhláška č. 6/2003 Sb., NV č. 361/2007 Sb.) | ||
| 50 | Water | Determination of polychlorinated biphenyl congeners 28, 52, 101, 118, 136, 153 and 180 by gas chromatography (GC/ECD) Regulated area: Tests |
SOP PCB-W (ČSN EN ISO 6468) | ||
| 51 | Earth, waste, sludge | Determination of polychlorinated biphenyl congeners 28, 52, 101, 118, 136, 153 and 180 by gas chromatography (GC/ECD) Regulated area: Tests |
SOP PCB-S (ČSN EN 17322) | ||
| 52 | Water | Determination of C10-C40 hydrocarbons by gas chromatography (GC/FID) Regulated area: Tests |
SOP C1040-VOD (ČSN EN ISO 9377-2) | ||
| 53 | Earth, waste, sludge | Determination of C10-C40 hydrocarbons by gas chromatography (GC/FID) Regulated area: Tests |
SOP C1040-ZEM (ČSN EN 14039) | ||
| 54 | Drinking and surface water | Determination of abioseston by microscopy Regulated area: Tests |
SOP MO-02 (ČSN 75 7713) | ||
| 55 | Drinking and surface water | Determination of the microscopic picture – number of organisms and number of living organisms Regulated area: Tests |
SOP MO-01 (ČSN 75 7712) | ||
| 56 | Water – surface, bathing | Determination of planktonic cyanobacteria by microscopy Regulated area: Tests |
SOP SINICE-01 (ČSN 75 7717) | ||
| 57 | Water – surface, waste, bathing | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration and direct plating Regulated area: Tests |
SOP TTK-01 (ČSN 75 7835) | ||
| 58 | Water – drinking, bottled, surface, waste, bathing | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP IE-01 (ČSN EN ISO 7899-2) | ||
| 59 | Water – drinking, bottled, bathing | Enumeration of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
SOP PA-01 (ČSN EN ISO 16266) | ||
| 60 | Water – surface, bathing, hot | Enumeration of coagulase-positive staphylococci and Staphylococcus aureus by membrane filtration Regulated area: Tests |
SOP SA-01 (ČSN EN ISO 6888-1) | ||
| 61 | Water – drinking, hot, surface, bathing, process | Enumeration of Legionella bacteria and Legionella pneumophila by membrane filtration Regulated area: Tests |
SOP LEG-01 (ČSN EN ISO 11731) | ||
| 62 | Water – drinking, bottled, bathing | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP CP-01 (Vyhláška č. 252/2004 Sb., příloha č. 6) | ||
| 63 | Water – bottled drinking, bathing | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP CP-02 (ČSN EN ISO 14189) | ||
| 64 | Water – drinking, bottled, bathing | Enumeration of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP KOLI-CCA (ČSN EN ISO 9308-1) | ||
| 65 | Water – drinking, hot, bottled, surface, waste, bathing | Enumeration of culturable micro-organisms at 22 °C and 36 °C by inoculation in a nutrient agar culture medium Regulated area: Tests |
SOP MO-22/36 (ČSN EN ISO 6222) | ||
| 66 | Water – drinking, bottled, surface, bathing | Enumeration of coliform bacteria and Escherichia coli by the most probable number method (MPN) Regulated area: Tests |
SOP KOLI-MPN (ČSN EN ISO 9308-2) | ||
| 67 | Swabs | Enumeration of total micro-organisms culturable at 30 °C by inoculation in a nutrient agar culture medium in swabs Regulated area: Tests |
SOP CPM-S (ČSN EN ISO 4833-1; ČSN EN ISO 4833-2) | ||
| 68 | Swabs | Enumeration of yeasts and moulds by inoculation in a nutrient agar culture medium in swabs Regulated area: Tests |
SOP KP-S (ČSN ISO 21527-1; ČSN ISO 21527-2) | ||
| 69 | Swabs | Detection and enumeration of Legionella bacteria and Legionella pneumophila by direct plating Regulated area: Tests |
SOP LEG-S (ČSN EN ISO 11731) | ||
| 70 | Workplace air, indoor air of buildings, outdoor air | Enumeration of total micro-organisms cultivated at 30 °C by the settle-plate method from air onto a solid nutrient medium Regulated area: Tests |
SOP CPM-AIR (Vyhláška č. 6/2003 Sb., příloha č. 3; ČSN EN ISO 4833-1; ČSN EN ISO 4833-2) | ||
| 71 | Workplace air, indoor air of buildings, outdoor air | Enumeration of yeasts and moulds cultivated at 25 °C by the settle-plate method from air onto a solid nutrient medium Regulated area: Tests |
SOP KP-AIR (Vyhláška č. 6/2003 Sb., příloha č. 3; ČSN ISO 21527-1; ČSN ISO 21527-2) | ||
| 72 | Emissions | Determination of gas velocity and volume flow rate in ducts Regulated area: Tests |
SOP OV01 (ČSN ISO 10780) | ||
| 73 | Emissions | Determination of the mass concentration of gaseous pollutants (NOx) with automated analysers (chemiluminescence) Regulated area: Tests |
SOP OV02 (ČSN ISO 10849; ČSN EN 14792) | ||
| 74 | Emissions | Determination of the mass concentration of gaseous pollutants (CO and SO2) and the volume concentration of carbon dioxide (CO2) with automated analysers (non-dispersive infrared spectrometry) Regulated area: Tests |
SOP OV03 (ČSN EN 15058; ČSN ISO 10396:1998; ČSN ISO 7935) | ||
| 75 | Emissions | Determination of the volume concentration of oxygen (O2) with an automated analyser (paramagnetic method) Regulated area: Tests |
SOP OV04 (ČSN EN 14789) | ||
| 76 | Emissions | Determination of the total mass concentration of organic substances expressed as total organic carbon (TOC) with automated analysers (FID) Regulated area: Tests |
SOP OV05 (ČSN EN 12619; ČSN EN 13526:2002) | ||
| 77 | Emissions – filters | Determination of the mass concentration of particulate matter (TZL) (gravimetry) Regulated area: Tests |
SOP OV06 (ČSN EN 13284-1) | ||
| 78 | Emissions – absorption solutions and/or filters | Determination of the mass concentration of persistent organic pollutants by calculation from measured values (PCDD/PCDF, PCB, PAH) Regulated area: Tests |
SOP OV07 (ČSN EN 1948-1; ČSN EN 1948-3; ČSN EN 1948-4) | ||
| 79 | Emissions | Determination of gas moisture in ducts (adsorption method, capacitive sensor) Regulated area: Tests |
SOP OV09 (ČSN EN 14790) | ||
| 80 | Workplace air – filters, indoor air of buildings – filters | Determination of total and respirable dust (PM2.5, PM5 and PM10) by gravimetry Regulated area: Tests |
SOP OV15 (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 482; ČSN EN 689; Vyhláška č. 43/2025 Sb.) | ||
| 81 | Workplace air, indoor air of buildings | Measurement of microclimatic conditions: globe thermometer temperature, air temperature, relative air humidity, air velocity, operative temperature Regulated area: Tests |
SOP OV12 (NV č. 361/2007 Sb.; Vyhláška č. 43/2025 Sb.; ČSN EN ISO 7726; ČSN EN ISO 7243; Metodický návod na měření a hodnocení mikroklimatických podmínek na pracovišti a vnitřního prostředí staveb, Věstník MZ ČR částka 8, ročník 2013) | ||
| 82 | Emissions – absorption solutions | Determination of the mass concentration of HCl gases and vapours collected in liquid by calculation from measured values Regulated area: Tests |
SOP OV16 (ČSN EN 1911) | ||
| 83 | Emissions – absorption solutions | Determination of the mass concentration of SO2 gases and vapours collected in liquid by calculation from measured values Regulated area: Tests |
SOP OV17 (ČSN EN 14791) | ||
| 84 | Workplace air, indoor air of buildings, outdoor air | Determination of the concentration of asbestos and mineral fibres by calculation from measured values Regulated area: Tests |
SOP OV18 (ČSN EN ISO 16000-7; Vyhláška č. 43/2025 Sb.; NV č. 361/2007 Sb.) | ||
| 85 | Workplace air, indoor air of buildings | Determination of the concentration of isocyanates by calculation from measured values 4,4-methylene diphenyl diisocyanate 2,4-toluene diisocyanate 2,6-toluene diisocyanate 1,6-hexamethylene diisocyanate isophorone diisocyanate Regulated area: Tests |
SOP OV19 (OSHA No.47; NV č. 361/2007 Sb.; Vyhláška č. 43/2025 Sb.; ČSN EN 482; ČSN EN 689) | ||
| 86 | Water – drinking, hot | Sampling of drinking water Regulated area: Sampling |
SOP VZ-PIT-01 (ČSN EN ISO 19458; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; Vyhláška č. 252/2004 Sb.) | ||
| 87 | Surface water | Sampling of surface water Regulated area: Sampling |
SOP VZ-POVRCH-01 (ČSN EN ISO 19458; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3) | ||
| 88 | Waste water | Sampling of waste water – manual sampling and sampling with an automatic sampler Regulated area: Sampling |
SOP VZ-ODPAD-01 (ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3) | ||
| 89 | Bathing water – artificial swimming pools and natural bathing sites | Sampling of bathing water Regulated area: Sampling |
SOP VZ-BAZ-01 (ČSN EN ISO 19458; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; Vyhláška č. 238/2011 Sb.) | ||
| 90 | Water for power generation | Sampling of water for power generation Regulated area: Sampling |
SOP VZ-ENER-01 (ČSN ISO 5667-7; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3) | ||
| 91 | Solid waste | Sampling of waste Regulated area: Sampling |
SOP VZ-ODP-01 (ČSN EN 14899; Zákon č. 541/2020 Sb.; Metodický pokyn č. 6 ke vzorkování odpadů, Věstník MŽP, roč. XVIII, č. 4/2008; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5) | ||
| 92 | Earths, soils, sludge, sediments, composts, biowaste | Sampling of earths, soils, sludge, sediments, composts and biowaste Regulated area: Sampling |
SOP VZ-ZEM-01 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; Vyhláška č. 400/2004 Sb.) | ||
| 93 | Articles of everyday use, work surfaces and premises of establishments, packaging, process equipment | Sampling of surfaces by swabbing for the determination of microbial contamination Regulated area: Sampling |
SOP VZ-STĚRY (ČSN 56 0100:1968; ČSN EN ISO 18593; ČSN P CEN ISO/TS 17728) | ||
| 94 | Workplace air, indoor air of buildings, outdoor air | Air sampling by aspiration with an air sampler (aeroscope) Regulated area: Sampling |
SOP VZ-MBAIR (Vyhláška č. 6/2003 Sb., příloha č. 3; ČSN EN 13098; NV č. 361/2007 Sb.) | ||
| 95 | Emissions | Sampling of particulate matter (isokinetic sampling with automatic or manual isokinetic control) Regulated area: Sampling |
SOP VZ01 (ČSN EN 13284-1) | ||
| 96 | Emissions | Sampling for the determination of individual volatile organic compounds (VOC) by collection on a solid sorbent benzene toluene ethylbenzene xylenes (sum of isomers) trichloroethene tetrachloroethene ethyl acetate butyl acetate ethanol 2-propanol 1-butanol 2-butanol 2-methyl-2-propanol acetone 2-butanone 2-methoxyethanol 2-ethoxyethanol 2-butoxyethanol Regulated area: Sampling |
SOP VZ02 (ČSN P CEN/TS 13649) | ||
| 97 | Emissions | Sampling for the determination of heavy metals – isokinetic sampling with automatic or manual isokinetic control and absorption into liquid Silver (Ag) Arsenic (As) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Mercury (Hg) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Vanadium (V) Zinc (Zn) Regulated area: Sampling |
SOP VZ07 (ČSN EN 14385; ČSN EN 13284-1; ČSN EN 13211) | ||
| 98 | Emissions | Sampling for the determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) – isokinetic sampling with automatic or manual isokinetic control, filtration-condensation method Regulated area: Sampling |
SOP VZ08 (ČSN EN 1948-1; ČSN EN 13284-1; ČSN EN 1948-4) | ||
| 99 | Emissions | Sampling of hydrogen chloride gases and vapours by absorption into liquid (non-isokinetic and isokinetic sampling with automatic or manual isokinetic control) Regulated area: Sampling |
SOP VZ09 (ČSN EN 1911) | ||
| 100 | Emissions | Sampling of sulphur dioxide gases and vapours by absorption into liquid (non-isokinetic and isokinetic sampling with automatic or manual isokinetic control) Regulated area: Sampling |
SOP VZ10 (ČSN EN 14791) | ||
| 101 | Workplace air, indoor air of buildings | Sampling of aerosol for the determination of metals by collection on a filter Silver (Ag) Arsenic (As) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Mercury (Hg) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Vanadium (V) Zinc (Zn) Regulated area: Sampling |
SOPVZ05 (NIOSH Method 7301; ČSN EN ISO 16000-1; ČSN EN 482; ČSN EN 689; Vyhláška č. 43/2025 Sb.; NV č. 361/2007 Sb.) | ||
| 102 | Workplace air, indoor air of buildings, outdoor air | Sampling of dust for the determination of total and respirable dust including the concentration of asbestos and mineral fibres Regulated area: Sampling |
SOP-VZ06 (NV č. 361/2007 Sb.; ČSN EN 481; ČSN EN 482; ČSN EN 689; ČSN EN ISO 16000-7; Vyhláška č. 43/2025 Sb.) | ||
| 103 | Workplace air, indoor air of buildings | Sampling for the determination of individual organic and inorganic substances by collection on a solid sorbent Regulated area: Sampling |
SOP VZ04 (ČSN EN 14662-2; NIOSH Method 1501; NIOSH Method 1450; NIOSH Method 1457; NIOSH Method 1401; NIOSH Method 1400; NIOSH Method 1022; NIOSH Method 1003; NIOSH Method 1300; NIOSH Method 1403, ČSN EN ISO 16000-1; ČSN EN ISO 16000-5; ČSN EN 482; ČSN EN 689; AOH Vol. 46, No 1, p. 89-96, 2002; Vyhláška č. 43/2025 Sb.; NV č. 361/2007 Sb.; Hery M. a kol. Ann. Occup. Hyg. 39, 427-439:1995) | ||
| 104 | Workplace air, indoor air of buildings | Sampling for the determination of isocyanates by collection on a solid sorbent 4,4-methylene diphenyl diisocyanate 2,4-toluene diisocyanate 2,6-toluene diisocyanate 1,6-hexamethylene diisocyanate isophorone diisocyanate Regulated area: Sampling |
SOP VZ11 (OSHA No. 47) | ||
Reference standards (259)
AOH Vol. 46, No 1, p. 89-96, 2002
Hery M. a kol. Ann. Occup. Hyg. 39, 427-439:1995
Horáková a kol., Chemické a fyzikální metody analýzy vod, SNTL Praha 1986, kap. 2.24.2.
Manuál Hach, metoda 8021 a 8167
Manuál Hach, metoda 8311
Manuál Hach, metoda HPT240
Manuál Hach, metoda LCl 400 a LCl 500
Metodický návod na měření a hodnocení mikroklimatických podmínek na pracovišti a vnitřního prostředí staveb, Věstník MZ ČR částka 8, ročník 2013
Metodický pokyn č. 6 ke vzorkování odpadů, Věstník MŽP, roč. XVIII, č. 4/2008
NIOSH Method 1003
NIOSH Method 1022
NIOSH Method 1300
NIOSH Method 1400
NIOSH Method 1401
NIOSH Method 1403
NIOSH Method 1450
NIOSH Method 1457
NIOSH Method 1501
NIOSH Method 7301
NV č. 361/2007 Sb.
OSHA No. 47
OSHA No.47
OSHA VI-6
SOP AAS-KYVETA-A
SOP AAS-KYVETA-S
SOP AAS-KYVETA-W
SOP AAS-PLAMEN-A
SOP AAS-PLAMEN-S
SOP AAS-PLAMEN-W
SOP AT-01
SOP BARVA-01
SOP BSK5-01
SOP C1040-VOD
SOP C1040-ZEM
SOP CHLF-01
SOP CHSKCr-01
SOP CLO2-01
SOP CP-01
SOP CP-02
SOP CPM-AIR
SOP CPM-S
SOP CaMg-01
SOP Cl-01
SOP Cl2-terén
SOP Dusík-02
SOP EK-01
SOP ELGR-01
SOP FEN-01
SOP Hg-01
SOP IE-01
SOP KNK-01
SOP KOLI-CCA
SOP KOLI-MPN
SOP KP-AIR
SOP KP-S
SOP LEG-01
SOP LEG-S
SOP MO-01
SOP MO-02
SOP MO-22/36
SOP NH4-02
SOP NH4TITR-01
SOP NL-01
SOP NO2-01
SOP NO3UV – 01
SOP O2-01
SOP OV01
SOP OV02
SOP OV03
SOP OV04
SOP OV05
SOP OV06
SOP OV07
SOP OV08
SOP OV09
SOP OV10
SOP OV12
SOP OV15
SOP OV16
SOP OV17
SOP OV18
SOP OV19
SOP OV20
SOP OZON-01
SOP PA-01
SOP PCB-S
SOP PCB-W
SOP PO4-01
SOP RAS-01
SOP RL-01
SOP Redox-01
SOP SA-01
SOP SENZOR-01
SOP SENZOR-02
SOP SINICE-01
SOP SO4-01
SOP SUŠINA-01
SOP T-01
SOP TOC-01
SOP TOL-02
SOP TTK-01
SOP TUKY-01
SOP TVRD-01
SOP VL-01
SOP VZ-BAZ-01
SOP VZ-ENER-01
SOP VZ-MBAIR
SOP VZ-ODP-01
SOP VZ-ODPAD-01
SOP VZ-PIT-01
SOP VZ-POVRCH-01
SOP VZ-STĚRY
SOP VZ-ZEM-01
SOP VZ01
SOP VZ02
SOP VZ04
SOP VZ07
SOP VZ08
SOP VZ09
SOP VZ10
SOP VZ11
SOP ZNK-01
SOP ZÁKAL-01
SOP pH-01
SOP-VZ06
SOPVZ05
TNI CEN/TR 15310-1
TNI CEN/TR 15310-2
TNI CEN/TR 15310-3
TNI CEN/TR 15310-4
TNI CEN/TR 15310-5
US EPA 375.4
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č. 252/2004 Sb., příloha č. 6
Vyhláška č. 400/2004 Sb.
Vyhláška č. 43/2025 Sb.
Vyhláška č. 6/2003 Sb.
Vyhláška č. 6/2003 Sb., příloha č. 3
Zákon č. 541/2020 Sb.
ČSN 56 0100:1968
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7367
ČSN 75 7372
ČSN 75 7385
ČSN 75 7400
ČSN 75 7440
ČSN 75 7508
ČSN 75 7509
ČSN 75 7573
ČSN 75 7712
ČSN 75 7713
ČSN 75 7717
ČSN 75 7835
ČSN EN 12260:2004
ČSN EN 1233
ČSN EN 12619
ČSN EN 12880
ČSN EN 13098
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13346:2001
ČSN EN 13526:2002
ČSN EN 14039
ČSN EN 14385
ČSN EN 14662-2
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 1484
ČSN EN 14899
ČSN EN 15058
ČSN EN 15934
ČSN EN 16173
ČSN EN 16174:2013
ČSN EN 1622
ČSN EN 17322
ČSN EN 1899-2
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4
ČSN EN 26777
ČSN EN 27888
ČSN EN 481
ČSN EN 482
ČSN EN 689
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10301
ČSN EN ISO 11731
ČSN EN ISO 14189
ČSN EN ISO 15009
ČSN EN ISO 15586
ČSN EN ISO 15587-1
ČSN EN ISO 15587-2
ČSN EN ISO 15680
ČSN EN ISO 16000-1
ČSN EN ISO 16000-5
ČSN EN ISO 16000-7
ČSN EN ISO 16266
ČSN EN ISO 18593
ČSN EN ISO 19458
ČSN EN ISO 21832
ČSN EN ISO 4833-1
ČSN EN ISO 4833-2
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6468
ČSN EN ISO 6878, kap. 4 a 7
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7243
ČSN EN ISO 7393-2
ČSN EN ISO 7726
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9963-1
ČSN ISO 10260
ČSN ISO 10396:1998
ČSN ISO 10523
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 11423-2
ČSN ISO 15705
ČSN ISO 21527-1
ČSN ISO 21527-2
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 5667-7
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6439
ČSN ISO 7150-1
ČSN ISO 7935
ČSN ISO 7980
ČSN ISO 8288
ČSN ISO 9297
ČSN ISO 9964-1
ČSN ISO 9964-2
ČSN P CEN ISO/TS 17728
ČSN P CEN/TS 13649
ČSN P CEN/TS 16188:2012