🇨🇿 Ekotechnika Ostrava s.r.o. PL
Environment
Ekotechnika Ostrava s.r.o. is a laboratory accredited by ČIA under number 1541 (Ostrava, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: Calculation from measured values, Filtration-absorption method, Automated analysers, NDIR method.
At a glance
- Accreditation number: ČIA 1541
- Methods in scope: 15
- Types of test objects: 1
- Techniques used: 9
- City: Ostrava, Czech Republic
- Valid until: 02-11-2026
- Accreditation number
- 1541
- Accreditation body
- ČIA
- Address
- Petřvaldská 316/104, Michálkovice, 715 00 Ostrava
- City
- Ostrava, Czech Republic
- Division
- EKOTECHNIKA Ostrava - Laboratorium Pomiarów Emisji
- Valid until
- 02-11-2026
What this laboratory tests (1)
- Emissions — 15 methods
Analytical techniques used (9)
- Calculation from measured values — 4 methods
- Filtration-absorption method — 2 methods
- Automated analysers, NDIR method — 1 method
- Automated analysers, paramagnetic method — 1 method
- Automated FID analysers — 1 method
- Condensation method and capacitive sensor — 1 method
- Filtration-condensation method — 1 method
- Gravimetric method — 1 method
- Trapping on a solid sorbent — 1 method
Certificate information
- Certificate date
- 10.06.2024
Accreditation scope — test methods (15)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Determination of flow velocity and volume flow rate Flow velocity Volume flow rate Regulated area: Tests |
SOP 1 (ČSN ISO 10780; ČSN ISO 16911-1) | ||
| 2 | Emissions | Determination of water vapour content in ducts by the condensation method and capacitive sensor Regulated area: Tests |
Condensation method and capacitive sensor | SOP 2 (ČSN EN 14790) | |
| 3 | Emissions | Determination of oxygen concentration by automated analysers using the paramagnetic method Oxygen (O2) Regulated area: Tests |
Automated analysers, paramagnetic method | SOP 3 (ČSN EN 14789) | |
| 4 | Emissions | Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers using the NDIR method Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO) Regulated area: Tests |
Automated analysers, NDIR method | SOP 4 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058) | |
| 5 | Emissions | Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated FID analysers Total organic carbon (TOC) Regulated area: Tests |
Automated FID analysers | SOP 5 (ČSN ISO 12619) | |
| 6 | Emissions | Determination of mass concentration of particulate pollutants by the gravimetric method Regulated area: Tests |
Gravimetric method | SOP 6 - B (ČSN ISO 13284-1) | |
| 7 | Emissions | Determination of mass concentration of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by calculation from measured values Arsenic (As) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Mercury (Hg) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Tellurium (Te) Thallium (Tl) Vanadium (V) Zinc (Zn) Regulated area: Tests |
Calculation from measured values | SOP 7 - B (ČSN EN 14385, ČSN EN 13211; ČSN EN 13284-1) | |
| 8 | Emissions | Determination of mass concentration of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by calculation from measured values Polychlorinated dibenzodioxins (PCDD) Polychlorinated dibenzofurans (PCDF) Polycyclic aromatic hydrocarbons (PAH) Polychlorinated biphenyls (PCB) Regulated area: Tests |
Calculation from measured values | SOP 8 - B (ČSN EN 1948-3; ČSN EN 1948-4+A1; ČSN EN 13284-1) | |
| 9 | Emissions | Determination of mass concentration of gaseous chlorides by calculation from measured values Gaseous chlorides (HCl) Regulated area: Tests |
Calculation from measured values | SOP 9 - B (ČSN EN 1911; ČSN EN 13284-1) | |
| 10 | Emissions | Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values Volatile organic compounds (VOCs) Regulated area: Tests |
Calculation from measured values | SOP 10 - B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) | |
| 11 | Emissions | Isokinetic sampling of particulate pollutants (manual isokinetic control) Regulated area: Sampling |
SOP 6 - A (ČSN ISO 13284-1) | ||
| 12 | Emissions | Isokinetic sampling for determination of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by the filtration-absorption method (manual isokinetic control) Regulated area: Sampling |
Filtration-absorption method | SOP 7 - A (ČSN EN 14385; ČSN EN 13211; ČSN EN 13284-1) | |
| 13 | Emissions | Isokinetic sampling for determination of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by the filtration-condensation method (manual isokinetic control) Regulated area: Sampling |
Filtration-condensation method | SOP 8 - A (ČSN EN 1948-1; ČSN EN 13284-1) | |
| 14 | Emissions | Isokinetic sampling for determination of gaseous chlorides by the filtration-absorption method (manual isokinetic control) Regulated area: Sampling |
Filtration-absorption method | SOP 9 - A (ČSN EN 1911; ČSN EN 13284-1 | |
| 15 | Emissions | Sampling of volatile organic compounds (VOCs) by trapping on a solid sorbent Regulated area: Sampling |
Trapping on a solid sorbent | SOP 10 - A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) | |
Reference standards (33)
SOP 1
SOP 10 - A
SOP 10 - B
SOP 2
SOP 3
SOP 4
SOP 5
SOP 6 - A
SOP 6 - B
SOP 7 - A
SOP 7 - B
SOP 8 - A
SOP 8 - B
SOP 9 - A
SOP 9 - B
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN ISO 16017-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 12619
ČSN ISO 13284-1
ČSN ISO 16911-1
ČSN ISO 7935
ČSN P CEN/TS 13649