Ekotechnika Ostrava s.r.o. is a laboratory accredited by ČIA under number 1541 (Ostrava, Czech Republic). Its accreditation scope covers 15 test methods in the following areas: Environment. Test objects include: Emissions. Most frequently used techniques: Calculation from measured values, Filtration-absorption method, Automated analysers, NDIR method.

At a glance

  • Accreditation number: ČIA 1541
  • Methods in scope: 15
  • Types of test objects: 1
  • Techniques used: 9
  • City: Ostrava, Czech Republic
  • Valid until: 02-11-2026
Accreditation number
1541
Accreditation body
ČIA
Address
Petřvaldská 316/104, Michálkovice, 715 00 Ostrava
City
Ostrava, Czech Republic
Division
EKOTECHNIKA Ostrava - Laboratorium Pomiarów Emisji
Valid until
02-11-2026

What this laboratory tests (1)

Analytical techniques used (9)

Certificate information

Certificate date
10.06.2024

Accreditation scope — test methods (15)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Determination of flow velocity and volume flow rate
Flow velocity Volume flow rate
Regulated area: Tests
SOP 1 (ČSN ISO 10780; ČSN ISO 16911-1)
2 Emissions Determination of water vapour content in ducts by the condensation method and capacitive sensor
Regulated area: Tests
Condensation method and capacitive sensor SOP 2 (ČSN EN 14790)
3 Emissions Determination of oxygen concentration by automated analysers using the paramagnetic method
Oxygen (O2)
Regulated area: Tests
Automated analysers, paramagnetic method SOP 3 (ČSN EN 14789)
4 Emissions Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers using the NDIR method
Sulphur dioxide (SO2) Nitrogen oxides (NOx) Carbon monoxide (CO)
Regulated area: Tests
Automated analysers, NDIR method SOP 4 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058)
5 Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated FID analysers
Total organic carbon (TOC)
Regulated area: Tests
Automated FID analysers SOP 5 (ČSN ISO 12619)
6 Emissions Determination of mass concentration of particulate pollutants by the gravimetric method
Regulated area: Tests
Gravimetric method SOP 6 - B (ČSN ISO 13284-1)
7 Emissions Determination of mass concentration of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by calculation from measured values
Arsenic (As) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Mercury (Hg) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Tellurium (Te) Thallium (Tl) Vanadium (V) Zinc (Zn)
Regulated area: Tests
Calculation from measured values SOP 7 - B (ČSN EN 14385, ČSN EN 13211; ČSN EN 13284-1)
8 Emissions Determination of mass concentration of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by calculation from measured values
Polychlorinated dibenzodioxins (PCDD) Polychlorinated dibenzofurans (PCDF) Polycyclic aromatic hydrocarbons (PAH) Polychlorinated biphenyls (PCB)
Regulated area: Tests
Calculation from measured values SOP 8 - B (ČSN EN 1948-3; ČSN EN 1948-4+A1; ČSN EN 13284-1)
9 Emissions Determination of mass concentration of gaseous chlorides by calculation from measured values
Gaseous chlorides (HCl)
Regulated area: Tests
Calculation from measured values SOP 9 - B (ČSN EN 1911; ČSN EN 13284-1)
10 Emissions Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values
Volatile organic compounds (VOCs)
Regulated area: Tests
Calculation from measured values SOP 10 - B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)
11 Emissions Isokinetic sampling of particulate pollutants (manual isokinetic control)
Regulated area: Sampling
SOP 6 - A (ČSN ISO 13284-1)
12 Emissions Isokinetic sampling for determination of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by the filtration-absorption method (manual isokinetic control)
Regulated area: Sampling
Filtration-absorption method SOP 7 - A (ČSN EN 14385; ČSN EN 13211; ČSN EN 13284-1)
13 Emissions Isokinetic sampling for determination of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by the filtration-condensation method (manual isokinetic control)
Regulated area: Sampling
Filtration-condensation method SOP 8 - A (ČSN EN 1948-1; ČSN EN 13284-1)
14 Emissions Isokinetic sampling for determination of gaseous chlorides by the filtration-absorption method (manual isokinetic control)
Regulated area: Sampling
Filtration-absorption method SOP 9 - A (ČSN EN 1911; ČSN EN 13284-1
15 Emissions Sampling of volatile organic compounds (VOCs) by trapping on a solid sorbent
Regulated area: Sampling
Trapping on a solid sorbent SOP 10 - A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)

Reference standards (33)

SOP 1
SOP 10 - A
SOP 10 - B
SOP 2
SOP 3
SOP 4
SOP 5
SOP 6 - A
SOP 6 - B
SOP 7 - A
SOP 7 - B
SOP 8 - A
SOP 8 - B
SOP 9 - A
SOP 9 - B
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 15058
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN ISO 16017-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 12619
ČSN ISO 13284-1
ČSN ISO 16911-1
ČSN ISO 7935
ČSN P CEN/TS 13649

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1541