{"lab":{"_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","address":"Petřvaldská 316/104, Michálkovice, 715 00 Ostrava","categories":["environment"],"city":"Ostrava","imported_at":"2026-03-08T10:42:44.590Z","methods_count":15,"name":"Ekotechnika Ostrava s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1541_273_2024_CS.pdf","1541_273_2024_EN.pdf"],"scope_summary":"Pomiary emisji pyłowych i gazowych substancji zanieczyszczających.","search_text":"ekotechnika ostrava s.r.o. petřvaldská 316/104, michálkovice, 715 00 ostrava 1541","status":"active","updated_at":"2026-03-08T14:52:13.333Z","valid_from":"","valid_until":"02-11-2026","website":"www.ekotechnikaostrava.cz","location":{"type":"Point","coordinates":[18.2625,49.8209]},"email_confidence":"high","email_mx":true,"email_source":"https://www.ekotechnikaostrava.cz/kontakt","map_coord":[49.837745,18.343804],"map_geo":"nominatim-street","certificate_date":"10.06.2024","certificate_no":"273/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary emisji pyłowych i gazowych substancji zanieczyszczających.","en":"Measurement of emissions of particulate and gaseous pollutants.","zh":"颗粒物和气态污染物排放测量。","cs":"Měření emisí tuhých a plynných znečišťujících látek."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"EKOTECHNIKA Ostrava - Laboratorium Pomiarów Emisji","lab_division_cs":"EKOTECHNIKA Ostrava - Laboratoř měření emisí","lab_division_en":"EKOTECHNIKA Ostrava - Emission Measurement Laboratory","lab_division_zh":"EKOTECHNIKA Ostrava——排放测量实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"Emise","pl":"gaz odlotowy zawierający substancje zanieczyszczające, odprowadzany w sposób zorganizowany lub uchodzący do powietrza atmosferycznego ze źródeł zanieczyszczania powietrza","en":"waste gas containing pollutants that is discharged in a controlled manner or escapes into the outdoor atmosphere from air pollution sources","zh":"从空气污染源以受控方式排出或逸散到室外大气中的含污染物废气","cs":"odpadní plyn s obsahem znečišťujících látek, který je odváděn řízeným způsobem nebo uniká do venkovní atmosféry ze zdrojů znečišťování ovzduší"},{"abbr":"NDIR","pl":"Niedyspersyjna spektrometria w podczerwieni","en":"Non-dispersive infrared spectrometry","zh":"非分散红外光谱法","cs":"nedisperzní infračervená spektrometrie"},{"abbr":"FID","pl":"Detekcja płomieniowo-jonizacyjna","en":"Flame ionisation detection","zh":"火焰离子化检测","cs":"plamenoionizační detekce"},{"abbr":"TOC","pl":"Suma lotnych substancji organicznych wyrażonych jako węgiel całkowity","en":"Sum of volatile organic compounds expressed as total carbon","zh":"以总碳表示的挥发性有机物总量","cs":"suma těkavých organických látek vyjádřených jako celkový uhlík"},{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard operating procedure","zh":"标准操作程序","cs":"standardní operační postup"},{"abbr":"PAH","pl":"Wielopierścieniowe węglowodory aromatyczne","en":"Polycyclic aromatic hydrocarbons","zh":"多环芳烃","cs":"polycyklické aromatické uhlovodíky"},{"abbr":"PCB","pl":"Polichlorowane bifenyle","en":"Polychlorinated biphenyls","zh":"多氯联苯","cs":"polychlorované bifenyly"},{"abbr":"PCDD/F","pl":"Polichlorowane dibenzodioksyny/furany","en":"Polychlorinated dibenzodioxins/furans","zh":"多氯二苯并二噁英/呋喃","cs":"polychlorované dibenzodioxiny/furany"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"76cf36322146b4ac784362627f55b89b5f06cf09db4c40d95d6e0c32d91cd225","source_pdf_url":"https://www.cai.cz/OA/pdf/P273_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"3d152890895fc0e0c52d1232","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie prędkości przepływu i strumienia objętości","methodology_en":"Determination of flow velocity and volume flow rate","methodology_zh":"流速和体积流量的测定","methodology_cs":"Stanovení rychlosti proudění a objemového toku","parameters":[{"name":"Prędkość przepływu","range":""},{"name":"Strumień objętości","range":""}],"parameters_en":[{"name":"Flow velocity","range":""},{"name":"Volume flow rate","range":""}],"parameters_zh":[{"name":"流速","range":""},{"name":"体积流量","range":""}],"parameters_cs":[{"name":"rychlosti proudění","range":""},{"name":"objemového toku","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie prędkości przepływu i strumienia objętości\nZakres:\nPrędkość przepływu\nStrumień objętości","reference":"SOP 1 (ČSN ISO 10780; ČSN ISO 16911-1)","norm_bases":["SOP 1","ČSN ISO 10780","ČSN ISO 16911-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie prędkości przepływu i strumienia objętości Prędkość przepływu  Strumień objętości  Emise Stanovení rychlosti proudění a objemového toku rychlosti proudění  objemového toku  SOP 1 (ČSN ISO 10780; ČSN ISO 16911-1) Emisja Oznaczanie predkosci przeplywu i strumienia objetosci Predkosc przeplywu  Strumien objetosci  Emise Stanoveni rychlosti proudeni a objemoveho toku rychlosti proudeni  objemoveho toku  SOP 1 (CSN ISO 10780; CSN ISO 16911-1)","search_en":"Emissions Determination of flow velocity and volume flow rate Flow velocity  Volume flow rate  SOP 1 (ČSN ISO 10780; ČSN ISO 16911-1)","search_zh":"排放 流速和体积流量的测定 流速  体积流量  SOP 1 (ČSN ISO 10780; ČSN ISO 16911-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cb572d24d14321bfe7d42337","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie zawartości pary wodnej w przewodzie metodą kondensacyjną i czujnikiem pojemnościowym","methodology_en":"Determination of water vapour content in ducts by the condensation method and capacitive sensor","methodology_zh":"冷凝法和电容传感器测定管道中水蒸气含量","methodology_cs":"Stanovení obsahu vodní páry v potrubí kondenzační metodou a kapacitním čidlem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda kondensacyjna i czujnik pojemnościowy","technique_en":"Condensation method and capacitive sensor","technique_zh":"冷凝法和电容传感器","technique_cs":"kondenzační metodou a kapacitním čidlem","techniques":["Metoda kondensacyjna i czujnik pojemnościowy"],"techniques_en":["Condensation method and capacitive sensor"],"techniques_zh":["冷凝法和电容传感器"],"techniques_cs":["kondenzační metodou a kapacitním čidlem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości pary wodnej w przewodzie metodą kondensacyjną i czujnikiem pojemnościowym\nMetoda kondensacyjna i czujnik pojemnościowy","reference":"SOP 2 (ČSN EN 14790)","norm_bases":["SOP 2","ČSN EN 14790"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie zawartości pary wodnej w przewodzie metodą kondensacyjną i czujnikiem pojemnościowym Metoda kondensacyjna i czujnik pojemnościowy Emise Stanovení obsahu vodní páry v potrubí kondenzační metodou a kapacitním čidlem kondenzační metodou a kapacitním čidlem SOP 2 (ČSN EN 14790) Emisja Oznaczanie zawartosci pary wodnej w przewodzie metoda kondensacyjna i czujnikiem pojemnosciowym Metoda kondensacyjna i czujnik pojemnosciowy Emise Stanoveni obsahu vodni pary v potrubi kondenzacni metodou a kapacitnim cidlem kondenzacni metodou a kapacitnim cidlem SOP 2 (CSN EN 14790)","search_en":"Emissions Determination of water vapour content in ducts by the condensation method and capacitive sensor Condensation method and capacitive sensor SOP 2 (ČSN EN 14790)","search_zh":"排放 冷凝法和电容传感器测定管道中水蒸气含量 冷凝法和电容传感器 SOP 2 (ČSN EN 14790)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fed3a228cc1ab63aa7592c18","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia tlenu analizatorami automatycznymi metodą paramagnetyczną","methodology_en":"Determination of oxygen concentration by automated analysers using the paramagnetic method","methodology_zh":"自动分析仪顺磁法测定氧浓度","methodology_cs":"Stanovení koncentrace kyslíku automatizovanými analyzátory paramagnetickou metodou","parameters":[{"name":"Tlen (O2)","range":""}],"parameters_en":[{"name":"Oxygen (O2)","range":""}],"parameters_zh":[{"name":"氧 (O2)","range":""}],"parameters_cs":[{"name":"kyslíku","range":""}],"technique":"Analizatory automatyczne, metoda paramagnetyczna","technique_en":"Automated analysers, paramagnetic method","technique_zh":"自动分析仪，顺磁法","technique_cs":"automatizovanými analyzátory paramagnetickou metodou","techniques":["Analizatory automatyczne, metoda paramagnetyczna"],"techniques_en":["Automated analysers, paramagnetic method"],"techniques_zh":["自动分析仪，顺磁法"],"techniques_cs":["automatizovanými analyzátory paramagnetickou metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia tlenu analizatorami automatycznymi metodą paramagnetyczną\nTlen (O2)\nAnalizatory automatyczne, metoda paramagnetyczna","reference":"SOP 3 (ČSN EN 14789)","norm_bases":["SOP 3","ČSN EN 14789"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia tlenu analizatorami automatycznymi metodą paramagnetyczną Analizatory automatyczne, metoda paramagnetyczna Tlen (O2)  Emise Stanovení koncentrace kyslíku automatizovanými analyzátory paramagnetickou metodou automatizovanými analyzátory paramagnetickou metodou kyslíku  SOP 3 (ČSN EN 14789) Emisja Oznaczanie stezenia tlenu analizatorami automatycznymi metoda paramagnetyczna Analizatory automatyczne, metoda paramagnetyczna Tlen (O2)  Emise Stanoveni koncentrace kysliku automatizovanymi analyzatory paramagnetickou metodou automatizovanymi analyzatory paramagnetickou metodou kysliku  SOP 3 (CSN EN 14789)","search_en":"Emissions Determination of oxygen concentration by automated analysers using the paramagnetic method Automated analysers, paramagnetic method Oxygen (O2)  SOP 3 (ČSN EN 14789)","search_zh":"排放 自动分析仪顺磁法测定氧浓度 自动分析仪，顺磁法 氧 (O2)  SOP 3 (ČSN EN 14789)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"51237d550bc4b9c00b340e5b","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi metodą NDIR","methodology_en":"Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers using the NDIR method","methodology_zh":"自动分析仪NDIR法测定气态污染物 (SO2、NOx、CO) 质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOx, CO) automatizovanými analyzátory metodou NDIR","parameters":[{"name":"Ditlenek siarki (SO2)","range":""},{"name":"Tlenki azotu (NOx)","range":""},{"name":"Tlenek węgla (CO)","range":""}],"parameters_en":[{"name":"Sulphur dioxide (SO2)","range":""},{"name":"Nitrogen oxides (NOx)","range":""},{"name":"Carbon monoxide (CO)","range":""}],"parameters_zh":[{"name":"二氧化硫 (SO2)","range":""},{"name":"氮氧化物 (NOx)","range":""},{"name":"一氧化碳 (CO)","range":""}],"parameters_cs":[{"name":"SO2","range":""},{"name":"NOx","range":""},{"name":"CO","range":""}],"technique":"Analizatory automatyczne, metoda NDIR (niedyspersyjna spektrometria w podczerwieni)","technique_en":"Automated analysers, NDIR method","technique_zh":"自动分析仪，NDIR法（非分散红外光谱法）","technique_cs":"automatizovanými analyzátory metodou NDIR","techniques":["Analizatory automatyczne, metoda NDIR (niedyspersyjna spektrometria w podczerwieni)"],"techniques_en":["Automated analysers, NDIR method"],"techniques_zh":["自动分析仪，NDIR法（非分散红外光谱法）"],"techniques_cs":["automatizovanými analyzátory metodou NDIR"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi metodą NDIR\nZakres:\nDitlenek siarki (SO2)\nTlenki azotu (NOx)\nTlenek węgla (CO)\nAnalizatory automatyczne, metoda NDIR (niedyspersyjna spektrometria w podczerwieni)","reference":"SOP 4 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058)","norm_bases":["SOP 4","ČSN ISO 7935","ČSN ISO 10849","ČSN EN 15058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego gazowych substancji zanieczyszczających (SO2, NOx, CO) analizatorami automatycznymi metodą NDIR Analizatory automatyczne, metoda NDIR (niedyspersyjna spektrometria w podczerwieni) Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek węgla (CO)  Emise Stanovení hmotnostní koncentrace plynných znečišťujících látek (SO2, NOx, CO) automatizovanými analyzátory metodou NDIR automatizovanými analyzátory metodou NDIR SO2  NOx  CO  SOP 4 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058) Emisja Oznaczanie stezenia masowego gazowych substancji zanieczyszczajacych (SO2, NOx, CO) analizatorami automatycznymi metoda NDIR Analizatory automatyczne, metoda NDIR (niedyspersyjna spektrometria w podczerwieni) Ditlenek siarki (SO2)  Tlenki azotu (NOx)  Tlenek wegla (CO)  Emise Stanoveni hmotnostni koncentrace plynnych znecistujicich latek (SO2, NOx, CO) automatizovanymi analyzatory metodou NDIR automatizovanymi analyzatory metodou NDIR SO2  NOx  CO  SOP 4 (CSN ISO 7935; CSN ISO 10849; CSN EN 15058)","search_en":"Emissions Determination of mass concentration of gaseous pollutants (SO2, NOx, CO) by automated analysers using the NDIR method Automated analysers, NDIR method Sulphur dioxide (SO2)  Nitrogen oxides (NOx)  Carbon monoxide (CO)  SOP 4 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058)","search_zh":"排放 自动分析仪NDIR法测定气态污染物 (SO2、NOx、CO) 质量浓度 自动分析仪，NDIR法（非分散红外光谱法） 二氧化硫 (SO2)  氮氧化物 (NOx)  一氧化碳 (CO)  SOP 4 (ČSN ISO 7935; ČSN ISO 10849; ČSN EN 15058)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"197d30ca290dd59929feaab6","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie łącznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi FID","methodology_en":"Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated FID analysers","methodology_zh":"自动FID分析仪测定以总有机碳 (TOC) 表示的有机物总质量浓度","methodology_cs":"Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory FID","parameters":[{"name":"Całkowity węgiel organiczny (TOC)","range":""}],"parameters_en":[{"name":"Total organic carbon (TOC)","range":""}],"parameters_zh":[{"name":"总有机碳 (TOC)","range":""}],"parameters_cs":[{"name":"TOC","range":""}],"technique":"Analizatory automatyczne FID (detekcja płomieniowo-jonizacyjna)","technique_en":"Automated FID analysers","technique_zh":"自动FID分析仪（火焰离子化检测）","technique_cs":"automatizovanými analyzátory FID","techniques":["Analizatory automatyczne FID (detekcja płomieniowo-jonizacyjna)"],"techniques_en":["Automated FID analysers"],"techniques_zh":["自动FID分析仪（火焰离子化检测）"],"techniques_cs":["automatizovanými analyzátory FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie łącznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi FID\nCałkowity węgiel organiczny (TOC)\nAnalizatory automatyczne FID (detekcja płomieniowo-jonizacyjna)","reference":"SOP 5 (ČSN ISO 12619)","norm_bases":["SOP 5","ČSN ISO 12619"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie łącznego stężenia masowego substancji organicznych wyrażonych jako całkowity węgiel organiczny (TOC) analizatorami automatycznymi FID Analizatory automatyczne FID (detekcja płomieniowo-jonizacyjna) Całkowity węgiel organiczny (TOC)  Emise Stanovení úhrnné hmotnostní koncentrace organických látek vyjádřených jako celkový organický uhlík (TOC) automatizovanými analyzátory FID automatizovanými analyzátory FID TOC  SOP 5 (ČSN ISO 12619) Emisja Oznaczanie lacznego stezenia masowego substancji organicznych wyrazonych jako calkowity wegiel organiczny (TOC) analizatorami automatycznymi FID Analizatory automatyczne FID (detekcja plomieniowo-jonizacyjna) Calkowity wegiel organiczny (TOC)  Emise Stanoveni uhrnne hmotnostni koncentrace organickych latek vyjadrenych jako celkovy organicky uhlik (TOC) automatizovanymi analyzatory FID automatizovanymi analyzatory FID TOC  SOP 5 (CSN ISO 12619)","search_en":"Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated FID analysers Automated FID analysers Total organic carbon (TOC)  SOP 5 (ČSN ISO 12619)","search_zh":"排放 自动FID分析仪测定以总有机碳 (TOC) 表示的有机物总质量浓度 自动FID分析仪（火焰离子化检测） 总有机碳 (TOC)  SOP 5 (ČSN ISO 12619)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1f7bb5e4ab7bc2f69916f044","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"6","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną","methodology_en":"Determination of mass concentration of particulate pollutants by the gravimetric method","methodology_zh":"重量法测定颗粒污染物质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetrickou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda grawimetryczna","technique_en":"Gravimetric method","technique_zh":"重量法","technique_cs":"gravimetrickou metodou","techniques":["Metoda grawimetryczna"],"techniques_en":["Gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrickou metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną\nMetoda grawimetryczna","reference":"SOP 6 - B (ČSN ISO 13284-1)","norm_bases":["SOP 6 - B","ČSN ISO 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Oznaczanie stężenia masowego pyłowych substancji zanieczyszczających metodą grawimetryczną Metoda grawimetryczna Emise Stanovení hmotnostní koncentrace tuhých znečišťujících látek gravimetrickou metodou gravimetrickou metodou SOP 6 - B (ČSN ISO 13284-1) Emisja Oznaczanie stezenia masowego pylowych substancji zanieczyszczajacych metoda grawimetryczna Metoda grawimetryczna Emise Stanoveni hmotnostni koncentrace tuhych znecistujicich latek gravimetrickou metodou gravimetrickou metodou SOP 6 - B (CSN ISO 13284-1)","search_en":"Emissions Determination of mass concentration of particulate pollutants by the gravimetric method Gravimetric method SOP 6 - B (ČSN ISO 13284-1)","search_zh":"排放 重量法测定颗粒污染物质量浓度 重量法 SOP 6 - B (ČSN ISO 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b2def47867390b16c53a8447","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"7","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego metali ciężkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by calculation from measured values","methodology_zh":"由测量值计算重金属 (As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn) 质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace těžkých kovů (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) výpočtem z naměřených hodnot","parameters":[{"name":"Arsen (As)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Rtęć (Hg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Tellur (Te)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Mercury (Hg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Tellurium (Te)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"砷 (As)","range":""},{"name":"铍 (Be)","range":""},{"name":"镉 (Cd)","range":""},{"name":"钴 (Co)","range":""},{"name":"铬 (Cr)","range":""},{"name":"铜 (Cu)","range":""},{"name":"汞 (Hg)","range":""},{"name":"锰 (Mn)","range":""},{"name":"镍 (Ni)","range":""},{"name":"铅 (Pb)","range":""},{"name":"锑 (Sb)","range":""},{"name":"硒 (Se)","range":""},{"name":"锡 (Sn)","range":""},{"name":"碲 (Te)","range":""},{"name":"铊 (Tl)","range":""},{"name":"钒 (V)","range":""},{"name":"锌 (Zn)","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Be","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Hg","range":""},{"name":"Mn","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Te","range":""},{"name":"Tl","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"Obliczenie z wartości zmierzonych","technique_en":"Calculation from measured values","technique_zh":"由测量值计算","technique_cs":"výpočtem z naměřených hodnot","techniques":["Obliczenie z wartości zmierzonych"],"techniques_en":["Calculation from measured values"],"techniques_zh":["由测量值计算"],"techniques_cs":["výpočtem z naměřených hodnot"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego metali ciężkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) obliczeniowo z wartości zmierzonych\nZakres:\nArsen (As)\nBeryl (Be)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nRtęć (Hg)\nMangan (Mn)\nNikiel (Ni)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nTellur (Te)\nTal (Tl)\nWanad (V)\nCynk (Zn)\nObliczenie z wartości zmierzonych","reference":"SOP 7 - B (ČSN EN 14385, ČSN EN 13211; ČSN EN 13284-1)","norm_bases":["SOP 7 - B","ČSN EN 14385","ČSN EN 13211","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisja Oznaczanie stężenia masowego metali ciężkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) obliczeniowo z wartości zmierzonych Obliczenie z wartości zmierzonych Arsen (As)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Rtęć (Hg)  Mangan (Mn)  Nikiel (Ni)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Emise Stanovení hmotnostní koncentrace těžkých kovů (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) výpočtem z naměřených hodnot výpočtem z naměřených hodnot As  Be  Cd  Co  Cr  Cu  Hg  Mn  Ni  Pb  Sb  Se  Sn  Te  Tl  V  Zn  SOP 7 - B (ČSN EN 14385, ČSN EN 13211; ČSN EN 13284-1) Emisja Oznaczanie stezenia masowego metali ciezkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) obliczeniowo z wartosci zmierzonych Obliczenie z wartosci zmierzonych Arsen (As)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Rtec (Hg)  Mangan (Mn)  Nikiel (Ni)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tellur (Te)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Emise Stanoveni hmotnostni koncentrace tezkych kovu (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) vypoctem z namerenych hodnot vypoctem z namerenych hodnot As  Be  Cd  Co  Cr  Cu  Hg  Mn  Ni  Pb  Sb  Se  Sn  Te  Tl  V  Zn  SOP 7 - B (CSN EN 14385, CSN EN 13211; CSN EN 13284-1)","search_en":"Emissions Determination of mass concentration of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by calculation from measured values Calculation from measured values Arsenic (As)  Beryllium (Be)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Mercury (Hg)  Manganese (Mn)  Nickel (Ni)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Tellurium (Te)  Thallium (Tl)  Vanadium (V)  Zinc (Zn)  SOP 7 - B (ČSN EN 14385, ČSN EN 13211; ČSN EN 13284-1)","search_zh":"排放 由测量值计算重金属 (As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn) 质量浓度 由测量值计算 砷 (As)  铍 (Be)  镉 (Cd)  钴 (Co)  铬 (Cr)  铜 (Cu)  汞 (Hg)  锰 (Mn)  镍 (Ni)  铅 (Pb)  锑 (Sb)  硒 (Se)  锡 (Sn)  碲 (Te)  铊 (Tl)  钒 (V)  锌 (Zn)  SOP 7 - B (ČSN EN 14385, ČSN EN 13211; ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d4ac92881b4620fc48240b1","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"8","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych (PCDD, PCDF, WWA, PCB) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by calculation from measured values","methodology_zh":"由测量值计算持久性有机污染物 (PCDD、PCDF、PAH、PCB) 质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace persistentních organických látek (PCDD, PCDF, PAH, PCB) výpočtem z naměřených hodnot","parameters":[{"name":"Polichlorowane dibenzodioksyny (PCDD)","range":""},{"name":"Polichlorowane dibenzofurany (PCDF)","range":""},{"name":"Wielopierścieniowe węglowodory aromatyczne (WWA/PAH)","range":""},{"name":"Polichlorowane bifenyle (PCB)","range":""}],"parameters_en":[{"name":"Polychlorinated dibenzodioxins (PCDD)","range":""},{"name":"Polychlorinated dibenzofurans (PCDF)","range":""},{"name":"Polycyclic aromatic hydrocarbons (PAH)","range":""},{"name":"Polychlorinated biphenyls (PCB)","range":""}],"parameters_zh":[{"name":"多氯二苯并二噁英 (PCDD)","range":""},{"name":"多氯二苯并呋喃 (PCDF)","range":""},{"name":"多环芳烃 (PAH)","range":""},{"name":"多氯联苯 (PCB)","range":""}],"parameters_cs":[{"name":"PCDD","range":""},{"name":"PCDF","range":""},{"name":"PAH","range":""},{"name":"PCB","range":""}],"technique":"Obliczenie z wartości zmierzonych","technique_en":"Calculation from measured values","technique_zh":"由测量值计算","technique_cs":"výpočtem z naměřených hodnot","techniques":["Obliczenie z wartości zmierzonych"],"techniques_en":["Calculation from measured values"],"techniques_zh":["由测量值计算"],"techniques_cs":["výpočtem z naměřených hodnot"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych (PCDD, PCDF, WWA, PCB) obliczeniowo z wartości zmierzonych\nZakres:\nPolichlorowane dibenzodioksyny (PCDD)\nPolichlorowane dibenzofurany (PCDF)\nWielopierścieniowe węglowodory aromatyczne (WWA/PAH)\nPolichlorowane bifenyle (PCB)\nObliczenie z wartości zmierzonych","reference":"SOP 8 - B (ČSN EN 1948-3; ČSN EN 1948-4+A1; ČSN EN 13284-1)","norm_bases":["SOP 8 - B","ČSN EN 1948-3","ČSN EN 1948-4+A1","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisja Oznaczanie stężenia masowego trwałych zanieczyszczeń organicznych (PCDD, PCDF, WWA, PCB) obliczeniowo z wartości zmierzonych Obliczenie z wartości zmierzonych Polichlorowane dibenzodioksyny (PCDD)  Polichlorowane dibenzofurany (PCDF)  Wielopierścieniowe węglowodory aromatyczne (WWA/PAH)  Polichlorowane bifenyle (PCB)  Emise Stanovení hmotnostní koncentrace persistentních organických látek (PCDD, PCDF, PAH, PCB) výpočtem z naměřených hodnot výpočtem z naměřených hodnot PCDD  PCDF  PAH  PCB  SOP 8 - B (ČSN EN 1948-3; ČSN EN 1948-4+A1; ČSN EN 13284-1) Emisja Oznaczanie stezenia masowego trwalych zanieczyszczen organicznych (PCDD, PCDF, WWA, PCB) obliczeniowo z wartosci zmierzonych Obliczenie z wartosci zmierzonych Polichlorowane dibenzodioksyny (PCDD)  Polichlorowane dibenzofurany (PCDF)  Wielopierscieniowe weglowodory aromatyczne (WWA/PAH)  Polichlorowane bifenyle (PCB)  Emise Stanoveni hmotnostni koncentrace persistentnich organickych latek (PCDD, PCDF, PAH, PCB) vypoctem z namerenych hodnot vypoctem z namerenych hodnot PCDD  PCDF  PAH  PCB  SOP 8 - B (CSN EN 1948-3; CSN EN 1948-4+A1; CSN EN 13284-1)","search_en":"Emissions Determination of mass concentration of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by calculation from measured values Calculation from measured values Polychlorinated dibenzodioxins (PCDD)  Polychlorinated dibenzofurans (PCDF)  Polycyclic aromatic hydrocarbons (PAH)  Polychlorinated biphenyls (PCB)  SOP 8 - B (ČSN EN 1948-3; ČSN EN 1948-4+A1; ČSN EN 13284-1)","search_zh":"排放 由测量值计算持久性有机污染物 (PCDD、PCDF、PAH、PCB) 质量浓度 由测量值计算 多氯二苯并二噁英 (PCDD)  多氯二苯并呋喃 (PCDF)  多环芳烃 (PAH)  多氯联苯 (PCB)  SOP 8 - B (ČSN EN 1948-3; ČSN EN 1948-4+A1; ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"707236486f4b4b256ffcbeb2","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"9","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego gazowych chlorków obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of gaseous chlorides by calculation from measured values","methodology_zh":"由测量值计算气态氯化物质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace plynných chloridů výpočtem z naměřených hodnot","parameters":[{"name":"Gazowe chlorki (HCl)","range":""}],"parameters_en":[{"name":"Gaseous chlorides (HCl)","range":""}],"parameters_zh":[{"name":"气态氯化物 (HCl)","range":""}],"parameters_cs":[{"name":"plynných chloridů","range":""}],"technique":"Obliczenie z wartości zmierzonych","technique_en":"Calculation from measured values","technique_zh":"由测量值计算","technique_cs":"výpočtem z naměřených hodnot","techniques":["Obliczenie z wartości zmierzonych"],"techniques_en":["Calculation from measured values"],"techniques_zh":["由测量值计算"],"techniques_cs":["výpočtem z naměřených hodnot"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego gazowych chlorków obliczeniowo z wartości zmierzonych\nGazowe chlorki (HCl)\nObliczenie z wartości zmierzonych","reference":"SOP 9 - B (ČSN EN 1911; ČSN EN 13284-1)","norm_bases":["SOP 9 - B","ČSN EN 1911","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisja Oznaczanie stężenia masowego gazowych chlorków obliczeniowo z wartości zmierzonych Obliczenie z wartości zmierzonych Gazowe chlorki (HCl)  Emise Stanovení hmotnostní koncentrace plynných chloridů výpočtem z naměřených hodnot výpočtem z naměřených hodnot plynných chloridů  SOP 9 - B (ČSN EN 1911; ČSN EN 13284-1) Emisja Oznaczanie stezenia masowego gazowych chlorkow obliczeniowo z wartosci zmierzonych Obliczenie z wartosci zmierzonych Gazowe chlorki (HCl)  Emise Stanoveni hmotnostni koncentrace plynnych chloridu vypoctem z namerenych hodnot vypoctem z namerenych hodnot plynnych chloridu  SOP 9 - B (CSN EN 1911; CSN EN 13284-1)","search_en":"Emissions Determination of mass concentration of gaseous chlorides by calculation from measured values Calculation from measured values Gaseous chlorides (HCl)  SOP 9 - B (ČSN EN 1911; ČSN EN 13284-1)","search_zh":"排放 由测量值计算气态氯化物质量浓度 由测量值计算 气态氯化物 (HCl)  SOP 9 - B (ČSN EN 1911; ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ccf8346c8b1cc0d4e71b6192","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"10","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Oznaczanie stężenia masowego lotnych związków organicznych (LZO/VOCs) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values","methodology_zh":"由测量值计算挥发性有机物 (VOCs) 质量浓度","methodology_cs":"Stanovení hmotnostní koncentrace těkavých organických látek (VOCs) výpočtem z naměřených hodnot","parameters":[{"name":"Lotne związki organiczne (VOCs)","range":""}],"parameters_en":[{"name":"Volatile organic compounds (VOCs)","range":""}],"parameters_zh":[{"name":"挥发性有机物 (VOCs)","range":""}],"parameters_cs":[{"name":"VOCs","range":""}],"technique":"Obliczenie z wartości zmierzonych","technique_en":"Calculation from measured values","technique_zh":"由测量值计算","technique_cs":"výpočtem z naměřených hodnot","techniques":["Obliczenie z wartości zmierzonych"],"techniques_en":["Calculation from measured values"],"techniques_zh":["由测量值计算"],"techniques_cs":["výpočtem z naměřených hodnot"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego lotnych związków organicznych (LZO/VOCs) obliczeniowo z wartości zmierzonych\nLotne związki organiczne (VOCs)\nObliczenie z wartości zmierzonych","reference":"SOP 10 - B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","norm_bases":["SOP 10 - B","ČSN P CEN/TS 13649","ČSN EN ISO 16017-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"laboratory determination of the analytes in the sample is carried out by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测机构在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Emisja Oznaczanie stężenia masowego lotnych związków organicznych (LZO/VOCs) obliczeniowo z wartości zmierzonych Obliczenie z wartości zmierzonych Lotne związki organiczne (VOCs)  Emise Stanovení hmotnostní koncentrace těkavých organických látek (VOCs) výpočtem z naměřených hodnot výpočtem z naměřených hodnot VOCs  SOP 10 - B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) Emisja Oznaczanie stezenia masowego lotnych zwiazkow organicznych (LZO/VOCs) obliczeniowo z wartosci zmierzonych Obliczenie z wartosci zmierzonych Lotne zwiazki organiczne (VOCs)  Emise Stanoveni hmotnostni koncentrace tekavych organickych latek (VOCs) vypoctem z namerenych hodnot vypoctem z namerenych hodnot VOCs  SOP 10 - B (CSN P CEN/TS 13649; CSN EN ISO 16017-1)","search_en":"Emissions Determination of mass concentration of volatile organic compounds (VOCs) by calculation from measured values Calculation from measured values Volatile organic compounds (VOCs)  SOP 10 - B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","search_zh":"排放 由测量值计算挥发性有机物 (VOCs) 质量浓度 由测量值计算 挥发性有机物 (VOCs)  SOP 10 - B (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c95d8bc8bcc877798cbd0d3b","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"1","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Izokinetyczne pobieranie próbek pyłowych substancji zanieczyszczających (ręczne sterowanie izokinetyką)","methodology_en":"Isokinetic sampling of particulate pollutants (manual isokinetic control)","methodology_zh":"颗粒污染物等速采样（手动等速控制）","methodology_cs":"Izokinetický odběr vzorku tuhých znečišťujících látek (manuální řízení izokinetiky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izokinetyczne pobieranie próbek pyłowych substancji zanieczyszczających (ręczne sterowanie izokinetyką)","reference":"SOP 6 - A (ČSN ISO 13284-1)","norm_bases":["SOP 6 - A","ČSN ISO 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Izokinetyczne pobieranie próbek pyłowych substancji zanieczyszczających (ręczne sterowanie izokinetyką) Emise Izokinetický odběr vzorku tuhých znečišťujících látek (manuální řízení izokinetiky) SOP 6 - A (ČSN ISO 13284-1) Emisja Izokinetyczne pobieranie probek pylowych substancji zanieczyszczajacych (reczne sterowanie izokinetyka) Emise Izokineticky odber vzorku tuhych znecistujicich latek (manualni rizeni izokinetiky) SOP 6 - A (CSN ISO 13284-1)","search_en":"Emissions Isokinetic sampling of particulate pollutants (manual isokinetic control) SOP 6 - A (ČSN ISO 13284-1)","search_zh":"排放 颗粒污染物等速采样（手动等速控制） SOP 6 - A (ČSN ISO 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c548cc7505c6684c74129f9","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"2","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Izokinetyczne pobieranie próbek do oznaczania metali ciężkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) metodą filtracyjno-absorpcyjną (ręczne sterowanie izokinetyką)","methodology_en":"Isokinetic sampling for determination of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by the filtration-absorption method (manual isokinetic control)","methodology_zh":"过滤-吸收法等速采样用于测定重金属 (As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn)（手动等速控制）","methodology_cs":"Izokinetický odběr vzorku pro stanovení těžkých kovů (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) metodou filtračně absorpční (manuální řízení izokinetiky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda filtracyjno-absorpcyjna","technique_en":"Filtration-absorption method","technique_zh":"过滤-吸收法","technique_cs":"metodou filtračně absorpční","techniques":["Metoda filtracyjno-absorpcyjna"],"techniques_en":["Filtration-absorption method"],"techniques_zh":["过滤-吸收法"],"techniques_cs":["metodou filtračně absorpční"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izokinetyczne pobieranie próbek do oznaczania metali ciężkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) metodą filtracyjno-absorpcyjną (ręczne sterowanie izokinetyką)\nMetoda filtracyjno-absorpcyjna","reference":"SOP 7 - A (ČSN EN 14385; ČSN EN 13211; ČSN EN 13284-1)","norm_bases":["SOP 7 - A","ČSN EN 14385","ČSN EN 13211","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Izokinetyczne pobieranie próbek do oznaczania metali ciężkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) metodą filtracyjno-absorpcyjną (ręczne sterowanie izokinetyką) Metoda filtracyjno-absorpcyjna Emise Izokinetický odběr vzorku pro stanovení těžkých kovů (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) metodou filtračně absorpční (manuální řízení izokinetiky) metodou filtračně absorpční SOP 7 - A (ČSN EN 14385; ČSN EN 13211; ČSN EN 13284-1) Emisja Izokinetyczne pobieranie probek do oznaczania metali ciezkich (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) metoda filtracyjno-absorpcyjna (reczne sterowanie izokinetyka) Metoda filtracyjno-absorpcyjna Emise Izokineticky odber vzorku pro stanoveni tezkych kovu (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) metodou filtracne absorpcni (manualni rizeni izokinetiky) metodou filtracne absorpcni SOP 7 - A (CSN EN 14385; CSN EN 13211; CSN EN 13284-1)","search_en":"Emissions Isokinetic sampling for determination of heavy metals (As, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, Pb, Sb, Se, Sn, Te, Tl, V, Zn) by the filtration-absorption method (manual isokinetic control) Filtration-absorption method SOP 7 - A (ČSN EN 14385; ČSN EN 13211; ČSN EN 13284-1)","search_zh":"排放 过滤-吸收法等速采样用于测定重金属 (As、Be、Cd、Co、Cr、Cu、Hg、Mn、Ni、Pb、Sb、Se、Sn、Te、Tl、V、Zn)（手动等速控制） 过滤-吸收法 SOP 7 - A (ČSN EN 14385; ČSN EN 13211; ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"61cbd64a1538342dfd46bd69","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"3","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Izokinetyczne pobieranie próbek do oznaczania trwałych zanieczyszczeń organicznych (PCDD, PCDF, WWA, PCB) metodą filtracyjno-kondensacyjną (ręczne sterowanie izokinetyką)","methodology_en":"Isokinetic sampling for determination of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by the filtration-condensation method (manual isokinetic control)","methodology_zh":"过滤-冷凝法等速采样用于测定持久性有机污染物 (PCDD、PCDF、PAH、PCB)（手动等速控制）","methodology_cs":"Izokinetický odběr vzorku pro stanovení persistentních organických látek (PCDD, PCDF, PAH, PCB) metodou filtračně kondenzační (manuální řízení izokinetiky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda filtracyjno-kondensacyjna","technique_en":"Filtration-condensation method","technique_zh":"过滤-冷凝法","technique_cs":"metodou filtračně kondenzační","techniques":["Metoda filtracyjno-kondensacyjna"],"techniques_en":["Filtration-condensation method"],"techniques_zh":["过滤-冷凝法"],"techniques_cs":["metodou filtračně kondenzační"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izokinetyczne pobieranie próbek do oznaczania trwałych zanieczyszczeń organicznych (PCDD, PCDF, WWA, PCB) metodą filtracyjno-kondensacyjną (ręczne sterowanie izokinetyką)\nMetoda filtracyjno-kondensacyjna","reference":"SOP 8 - A (ČSN EN 1948-1; ČSN EN 13284-1)","norm_bases":["SOP 8 - A","ČSN EN 1948-1","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Izokinetyczne pobieranie próbek do oznaczania trwałych zanieczyszczeń organicznych (PCDD, PCDF, WWA, PCB) metodą filtracyjno-kondensacyjną (ręczne sterowanie izokinetyką) Metoda filtracyjno-kondensacyjna Emise Izokinetický odběr vzorku pro stanovení persistentních organických látek (PCDD, PCDF, PAH, PCB) metodou filtračně kondenzační (manuální řízení izokinetiky) metodou filtračně kondenzační SOP 8 - A (ČSN EN 1948-1; ČSN EN 13284-1) Emisja Izokinetyczne pobieranie probek do oznaczania trwalych zanieczyszczen organicznych (PCDD, PCDF, WWA, PCB) metoda filtracyjno-kondensacyjna (reczne sterowanie izokinetyka) Metoda filtracyjno-kondensacyjna Emise Izokineticky odber vzorku pro stanoveni persistentnich organickych latek (PCDD, PCDF, PAH, PCB) metodou filtracne kondenzacni (manualni rizeni izokinetiky) metodou filtracne kondenzacni SOP 8 - A (CSN EN 1948-1; CSN EN 13284-1)","search_en":"Emissions Isokinetic sampling for determination of persistent organic pollutants (PCDD, PCDF, PAH, PCB) by the filtration-condensation method (manual isokinetic control) Filtration-condensation method SOP 8 - A (ČSN EN 1948-1; ČSN EN 13284-1)","search_zh":"排放 过滤-冷凝法等速采样用于测定持久性有机污染物 (PCDD、PCDF、PAH、PCB)（手动等速控制） 过滤-冷凝法 SOP 8 - A (ČSN EN 1948-1; ČSN EN 13284-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eebe6adebbbed3aa54a020cf","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"4","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Izokinetyczne pobieranie próbek do oznaczania gazowych chlorków metodą filtracyjno-absorpcyjną (ręczne sterowanie izokinetyką)","methodology_en":"Isokinetic sampling for determination of gaseous chlorides by the filtration-absorption method (manual isokinetic control)","methodology_zh":"过滤-吸收法等速采样用于测定气态氯化物（手动等速控制）","methodology_cs":"Izokinetický odběr vzorku pro stanovení plynných chloridů metodou filtračně absorpční (manuální řízení izokinetiky)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda filtracyjno-absorpcyjna","technique_en":"Filtration-absorption method","technique_zh":"过滤-吸收法","technique_cs":"metodou filtračně absorpční","techniques":["Metoda filtracyjno-absorpcyjna"],"techniques_en":["Filtration-absorption method"],"techniques_zh":["过滤-吸收法"],"techniques_cs":["metodou filtračně absorpční"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Izokinetyczne pobieranie próbek do oznaczania gazowych chlorków metodą filtracyjno-absorpcyjną (ręczne sterowanie izokinetyką)\nMetoda filtracyjno-absorpcyjna","reference":"SOP 9 - A (ČSN EN 1911; ČSN EN 13284-1","norm_bases":["SOP 9 - A","ČSN EN 1911","ČSN EN 13284-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Izokinetyczne pobieranie próbek do oznaczania gazowych chlorków metodą filtracyjno-absorpcyjną (ręczne sterowanie izokinetyką) Metoda filtracyjno-absorpcyjna Emise Izokinetický odběr vzorku pro stanovení plynných chloridů metodou filtračně absorpční (manuální řízení izokinetiky) metodou filtračně absorpční SOP 9 - A (ČSN EN 1911; ČSN EN 13284-1 Emisja Izokinetyczne pobieranie probek do oznaczania gazowych chlorkow metoda filtracyjno-absorpcyjna (reczne sterowanie izokinetyka) Metoda filtracyjno-absorpcyjna Emise Izokineticky odber vzorku pro stanoveni plynnych chloridu metodou filtracne absorpcni (manualni rizeni izokinetiky) metodou filtracne absorpcni SOP 9 - A (CSN EN 1911; CSN EN 13284-1","search_en":"Emissions Isokinetic sampling for determination of gaseous chlorides by the filtration-absorption method (manual isokinetic control) Filtration-absorption method SOP 9 - A (ČSN EN 1911; ČSN EN 13284-1","search_zh":"排放 过滤-吸收法等速采样用于测定气态氯化物（手动等速控制） 过滤-吸收法 SOP 9 - A (ČSN EN 1911; ČSN EN 13284-1","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9a90f93e5844099d73f77f05","lab_id":"69ad52a4de79e566650fd47c","country":"CZ","accr_number":"1541","accr_body":"ČIA","row_label":"5","test_object":"Emisja","test_object_en":"Emissions","test_object_zh":"排放","test_object_cs":"Emise","methodology":"Pobieranie próbek lotnych związków organicznych (VOCs) przez wychwyt na sorbencie stałym","methodology_en":"Sampling of volatile organic compounds (VOCs) by trapping on a solid sorbent","methodology_zh":"固体吸附剂捕集法采集挥发性有机物 (VOCs) 样品","methodology_cs":"Odběr vzorku těkavých organických látek (VOCs) záchytem na pevný sorbent","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Wychwyt na sorbencie stałym","technique_en":"Trapping on a solid sorbent","technique_zh":"固体吸附剂捕集","technique_cs":"záchytem na pevný sorbent","techniques":["Wychwyt na sorbencie stałym"],"techniques_en":["Trapping on a solid sorbent"],"techniques_zh":["固体吸附剂捕集"],"techniques_cs":["záchytem na pevný sorbent"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek lotnych związków organicznych (VOCs) przez wychwyt na sorbencie stałym\nWychwyt na sorbencie stałym","reference":"SOP 10 - A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","norm_bases":["SOP 10 - A","ČSN P CEN/TS 13649","ČSN EN ISO 16017-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Emisja Pobieranie próbek lotnych związków organicznych (VOCs) przez wychwyt na sorbencie stałym Wychwyt na sorbencie stałym Emise Odběr vzorku těkavých organických látek (VOCs) záchytem na pevný sorbent záchytem na pevný sorbent SOP 10 - A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1) Emisja Pobieranie probek lotnych zwiazkow organicznych (VOCs) przez wychwyt na sorbencie stalym Wychwyt na sorbencie stalym Emise Odber vzorku tekavych organickych latek (VOCs) zachytem na pevny sorbent zachytem na pevny sorbent SOP 10 - A (CSN P CEN/TS 13649; CSN EN ISO 16017-1)","search_en":"Emissions Sampling of volatile organic compounds (VOCs) by trapping on a solid sorbent Trapping on a solid sorbent SOP 10 - A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","search_zh":"排放 固体吸附剂捕集法采集挥发性有机物 (VOCs) 样品 固体吸附剂捕集 SOP 10 - A (ČSN P CEN/TS 13649; ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}