🇨🇿 TOP – ENVI Tech Brno, s.r.o. PL
Environment
TOP – ENVI Tech Brno, s.r.o. is a laboratory accredited by ČIA under number 1536 (Brno, Czech Republic). Its accreditation scope covers 18 test methods in the following areas: Environment. Test objects include: Emissions, Emissions, ambient air (immissions), Automated emission measuring systems.
At a glance
- Accreditation number: ČIA 1536
- Methods in scope: 18
- Types of test objects: 3
- City: Brno, Czech Republic
- Valid until: 12-06-2031
- Accreditation number
- 1536
- Accreditation body
- ČIA
- Address
- Křižíkova 70b, 612 00 Brno
- City
- Brno, Czech Republic
- Division
- Laboratorium Badawcze Jakości Powietrza
- Valid until
- 12-06-2031
What this laboratory tests (3)
- Emissions — 15 methods
- Emissions, ambient air (immissions) — 2 methods
- Automated emission measuring systems — 1 method
Certificate information
- Certificate date
- 12.06.2026
Accreditation scope — test methods (18)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Emissions | Gravimetric determination of mass concentration of particulate matter, PM10 and PM2.5 fractions | SOP 1 (ČSN EN 13284-1; ČSN EN ISO 23210) | ||
| 2 | Emissions | Determination of mass concentration of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Sn, Se, Hg) by calculation from measured values Arsenic (As) Cadmium (Cd) Chromium (Cr) Cobalt (Co) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Thallium (Tl) Vanadium (V) Zinc (Zn) Tin (Sn) Selenium (Se) Mercury (Hg) |
SOP 2 (ČSN EN 14385; ČSN EN 13211) | ||
| 3 | Emissions | Determination of mass concentration of gases and vapours (HCl, HF, ammonia, cyanides, SO2) by calculation from measured values Hydrogen chloride (HCl) Hydrogen fluoride (HF) ammonia cyanides Sulphur dioxide (SO2) |
SOP 3 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN EN ISO 21877; ČSN 83 4728; ČSN EN 14791) | ||
| 4 | Emissions | Determination of mass concentration of volatile organic compounds (VOC) by calculation from measured values | SOP 4 (ČSN EN ISO 16017-1; ČSN P CEN/TS 13649) | ||
| 5 | Emissions | Determination of mass concentration of persistent organic pollutants (PCDD/PCDF, PCB, PAH) by calculation from measured values | SOP 5 (ČSN EN 1948-1; ČSN EN 1948-3; ČSN EN 1948-4; ISO 11338) | ||
| 6 | Emissions | Determination of mass concentration of gaseous pollutants (NO, NO2, SO2, CO) by NDIR method Nitrogen monoxide (NO) Nitrogen dioxide (NO2) Sulphur dioxide (SO2) Carbon monoxide (CO) |
SOP 6 (ČSN EN 15259; ČSN ISO 10849; ČSN ISO 7935; ČSN EN 15058) | ||
| 7 | Emissions | Determination of volume concentration of oxygen (O2) by paramagnetic method | SOP 6 část 2 (ČSN EN 15259; ČSN EN 14789) | ||
| 8 | Emissions | Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by FID method | SOP 6 část 3 (ČSN EN 15259; ČSN EN 12619) | ||
| 9 | Emissions | Determination of flow velocity and volume flow rate | SOP 7 část 1 (ČSN ISO 10780; ČSN EN ISO 16911-1) | ||
| 10 | Emissions | Determination of water vapour content (H2O) by condensation method and capacitive sensor | SOP 7 část 2 (ČSN EN 14790) | ||
| 11 | Emissions, ambient air (immissions) | Determination of odour concentration by dynamic olfactometry | SOP 10 (ČSN EN 13725) | ||
| 12 | Automated emission measuring systems | Quality assurance of automated measuring systems | SOP 11 (ČSN EN 14181, čl. 6.3-6.8; QAL2, čl.8 AST) | ||
| 13 | Emissions | Isokinetic sampling of particulate matter, PM10 and PM2.5 fractions, with automatic and manual isokinetic control Regulated area: Sampling |
SOP 1/O (ČSN EN 13284-1) | ||
| 14 | Emissions | Isokinetic sampling for determination of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Sn, Se, Hg) with automatic isokinetic control Regulated area: Sampling |
SOP 2/O (ČSN EN 14385; ČSN EN 13211) | ||
| 15 | Emissions | Sampling of gases and vapours (HCl, HF, ammonia, cyanides, SO2) by absorption into liquid Regulated area: Sampling |
SOP 3/O (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN EN ISO 21877; ČSN 83 4728; ČSN EN 14791) | ||
| 16 | Emissions | Sampling of volatile organic compounds (VOC) by trapping on solid sorbent Regulated area: Sampling |
SOP 4/O (ČSN EN ISO16017-1; ČSN P CEN/TS 13649) | ||
| 17 | Emissions | Isokinetic sampling for determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) with automatic isokinetic control Regulated area: Sampling |
SOP 5/O (ČSN EN 1948-1; ČSN EN 1948-4) | ||
| 18 | Emissions, ambient air (immissions) | Sampling of odorous substances Regulated area: Sampling |
SOP 10/O (ČSN EN 13725) | ||
Reference standards (45)
ISO 11338
SOP 1
SOP 1/O
SOP 10
SOP 10/O
SOP 11
SOP 2
SOP 2/O
SOP 3
SOP 3/O
SOP 4
SOP 4/O
SOP 5
SOP 5/O
SOP 6
SOP 6 část 2
SOP 6 část 3
SOP 7 část 1
SOP 7 část 2
ČSN 83 4728
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13725
ČSN EN 14181
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 15058
ČSN EN 15259
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4
ČSN EN ISO 16017-1
ČSN EN ISO 16911-1
ČSN EN ISO 21877
ČSN EN ISO 23210
ČSN EN ISO16017-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 13649
ČSN P CEN/TS 17340