🇨🇿 TOP – ENVI Tech Brno, s.r.o. PL

ČIA 1536 • Brno, Czech Republic • 18 methods

Environment

TOP – ENVI Tech Brno, s.r.o. is a laboratory accredited by ČIA under number 1536 (Brno, Czech Republic). Its accreditation scope covers 18 test methods in the following areas: Environment. Test objects include: Emissions, Emissions, ambient air (immissions), Automated emission measuring systems.

At a glance

  • Accreditation number: ČIA 1536
  • Methods in scope: 18
  • Types of test objects: 3
  • City: Brno, Czech Republic
  • Valid until: 12-06-2031
Accreditation number
1536
Accreditation body
ČIA
Address
Křižíkova 70b, 612 00 Brno
City
Brno, Czech Republic
Division
Laboratorium Badawcze Jakości Powietrza
Valid until
12-06-2031

What this laboratory tests (3)

Certificate information

Certificate date
12.06.2026

Accreditation scope — test methods (18)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Emissions Gravimetric determination of mass concentration of particulate matter, PM10 and PM2.5 fractions SOP 1 (ČSN EN 13284-1; ČSN EN ISO 23210)
2 Emissions Determination of mass concentration of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Sn, Se, Hg) by calculation from measured values
Arsenic (As) Cadmium (Cd) Chromium (Cr) Cobalt (Co) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Thallium (Tl) Vanadium (V) Zinc (Zn) Tin (Sn) Selenium (Se) Mercury (Hg)
SOP 2 (ČSN EN 14385; ČSN EN 13211)
3 Emissions Determination of mass concentration of gases and vapours (HCl, HF, ammonia, cyanides, SO2) by calculation from measured values
Hydrogen chloride (HCl) Hydrogen fluoride (HF) ammonia cyanides Sulphur dioxide (SO2)
SOP 3 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN EN ISO 21877; ČSN 83 4728; ČSN EN 14791)
4 Emissions Determination of mass concentration of volatile organic compounds (VOC) by calculation from measured values SOP 4 (ČSN EN ISO 16017-1; ČSN P CEN/TS 13649)
5 Emissions Determination of mass concentration of persistent organic pollutants (PCDD/PCDF, PCB, PAH) by calculation from measured values SOP 5 (ČSN EN 1948-1; ČSN EN 1948-3; ČSN EN 1948-4; ISO 11338)
6 Emissions Determination of mass concentration of gaseous pollutants (NO, NO2, SO2, CO) by NDIR method
Nitrogen monoxide (NO) Nitrogen dioxide (NO2) Sulphur dioxide (SO2) Carbon monoxide (CO)
SOP 6 (ČSN EN 15259; ČSN ISO 10849; ČSN ISO 7935; ČSN EN 15058)
7 Emissions Determination of volume concentration of oxygen (O2) by paramagnetic method SOP 6 část 2 (ČSN EN 15259; ČSN EN 14789)
8 Emissions Determination of mass concentration of organic substances expressed as total organic carbon (TOC) by FID method SOP 6 část 3 (ČSN EN 15259; ČSN EN 12619)
9 Emissions Determination of flow velocity and volume flow rate SOP 7 část 1 (ČSN ISO 10780; ČSN EN ISO 16911-1)
10 Emissions Determination of water vapour content (H2O) by condensation method and capacitive sensor SOP 7 část 2 (ČSN EN 14790)
11 Emissions, ambient air (immissions) Determination of odour concentration by dynamic olfactometry SOP 10 (ČSN EN 13725)
12 Automated emission measuring systems Quality assurance of automated measuring systems SOP 11 (ČSN EN 14181, čl. 6.3-6.8; QAL2, čl.8 AST)
13 Emissions Isokinetic sampling of particulate matter, PM10 and PM2.5 fractions, with automatic and manual isokinetic control
Regulated area: Sampling
SOP 1/O (ČSN EN 13284-1)
14 Emissions Isokinetic sampling for determination of metals (As, Cd, Cr, Co, Cu, Mn, Ni, Pb, Sb, Tl, V, Zn, Sn, Se, Hg) with automatic isokinetic control
Regulated area: Sampling
SOP 2/O (ČSN EN 14385; ČSN EN 13211)
15 Emissions Sampling of gases and vapours (HCl, HF, ammonia, cyanides, SO2) by absorption into liquid
Regulated area: Sampling
SOP 3/O (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN EN ISO 21877; ČSN 83 4728; ČSN EN 14791)
16 Emissions Sampling of volatile organic compounds (VOC) by trapping on solid sorbent
Regulated area: Sampling
SOP 4/O (ČSN EN ISO16017-1; ČSN P CEN/TS 13649)
17 Emissions Isokinetic sampling for determination of persistent organic pollutants (PCDD/PCDF, PCB, PAH) with automatic isokinetic control
Regulated area: Sampling
SOP 5/O (ČSN EN 1948-1; ČSN EN 1948-4)
18 Emissions, ambient air (immissions) Sampling of odorous substances
Regulated area: Sampling
SOP 10/O (ČSN EN 13725)

Reference standards (45)

ISO 11338
SOP 1
SOP 1/O
SOP 10
SOP 10/O
SOP 11
SOP 2
SOP 2/O
SOP 3
SOP 3/O
SOP 4
SOP 4/O
SOP 5
SOP 5/O
SOP 6
SOP 6 část 2
SOP 6 část 3
SOP 7 část 1
SOP 7 část 2
ČSN 83 4728
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13725
ČSN EN 14181
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 15058
ČSN EN 15259
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4
ČSN EN ISO 16017-1
ČSN EN ISO 16911-1
ČSN EN ISO 21877
ČSN EN ISO 23210
ČSN EN ISO16017-1
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 7935
ČSN P CEN/TS 13649
ČSN P CEN/TS 17340

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1536