🇨🇿 Monhart Akustik s.r.o. PL
Environment
Monhart Akustik s.r.o. is a laboratory accredited by ČIA under number 1467 (Švihov, Czech Republic). Its accreditation scope covers 14 test methods in the following areas: Environment. Test objects include: Workplace and indoor air, Enclosed spaces in buildings, Machinery and electrical equipment, Transformers.
At a glance
- Accreditation number: ČIA 1467
- Methods in scope: 14
- Types of test objects: 7
- City: Švihov, Czech Republic
- Valid until: 31-10-2028
- Accreditation number
- 1467
- Accreditation body
- ČIA
- Address
- Jiráskova 259, 340 12 Švihov
- City
- Švihov, Czech Republic
- Division
- laboratorium badawcze František Monhart
- Valid until
- 31-10-2028
What this laboratory tests (7)
- Workplace and indoor air — 4 methods
- Enclosed spaces in buildings — 2 methods
- Machinery and electrical equipment — 2 methods
- Transformers — 2 methods
- Wall and floor constructions in buildings — 2 methods
- Non-working environment (outdoor environment, building interiors, traffic) — 1 method
- Working environment — 1 method
Laboratory sections (2)
- Plzeň site — 10 methods
- Švihov site — 4 methods
Laboratory locations
- Pracownia Švihov — Jiráskova 259
- Pracownia Pilzno — Teslova 1202/3
Certificate information
- Certificate date
- 14.03.2025
Accreditation scope — test methods (14)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Plzeň site | |||||
| 1 | Non-working environment (outdoor environment, building interiors, traffic) | Noise measurement Regulated area: Tests |
ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, částka 11/2017 | ||
| 2 | Working environment | Noise measurement Regulated area: Tests |
SOP 1 (ČSN EN ISO 9612; ČSN ISO 9612:2000; HEM-300-26.4.01-16344) | ||
| 3 | Workplace and indoor air | Determination of concentration of gases and vapours by calculation from measured values volatile organic compounds metals aldehydes petrol (gasolines) mineral acids ammonia mineral oils silicon dioxide (SiO2) ozone Regulated area: Tests |
SOP 3 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.) | ||
| 4 | Workplace and indoor air | Determination of mass concentration of inhalable and respirable fractions of airborne dust and number concentration of mineral and asbestos fibres by calculation from measured values Regulated area: Tests |
SOP 4 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7) | ||
| 5 | Machinery and electrical equipment | Measurement of sound power level Regulated area: Tests |
ČSN EN ISO 3746 | ||
| 6 | Transformers | Measurement of sound power level Regulated area: Tests |
ČSN EN 60076-10 ed. 2, mimo čl. 11.3 | ||
| 7 | Enclosed spaces in buildings | Measurement of reverberation time Regulated area: Tests |
ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2 | ||
| 8 | Wall and floor constructions in buildings | Measurement of airborne sound insulation Regulated area: Tests |
ČSN EN ISO 16283-1 | ||
| 9 | Workplace and indoor air | Sampling of gases and vapours by sorption on a solid sorbent or trapping on a filter Regulated area: Sampling |
SOP V1 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.) | ||
| 10 | Workplace and indoor air | Sampling of inhalable and respirable fractions of airborne dust and mineral and asbestos fibres on a filter Regulated area: Sampling |
SOP V2 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7) | ||
| Švihov site | |||||
| 11 | Machinery and electrical equipment | Measurement of sound power level Regulated area: Tests |
ČSN EN ISO 3746 | ||
| 12 | Transformers | Measurement of sound power level Regulated area: Tests |
ČSN EN 60076-10 ed. 2, mimo čl. 11.3 | ||
| 13 | Enclosed spaces in buildings | Measurement of reverberation time Regulated area: Tests |
ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2 | ||
| 14 | Wall and floor constructions in buildings | Measurement of airborne sound insulation Regulated area: Tests |
ČSN EN ISO 16283-1 | ||
Reference standards (22)
CSN ISO 3382-2
HEM-300-26.4.01-16344
Nařízení vlády 361/2007 Sb.
SOP 1
SOP 3
SOP 4
SOP V1
SOP V2
Vyhláška č. 6/2003 Sb.
Věstník MZ ČR, částka 11/2017
ČSN EN 481
ČSN EN 60076-10 ed. 2
ČSN EN 689+AC
ČSN EN ISO 16000-7
ČSN EN ISO 16283-1
ČSN EN ISO 3746
ČSN EN ISO 9612
ČSN ISO 1996-1
ČSN ISO 1996-2
ČSN ISO 3382-1
ČSN ISO 3382:1999
ČSN ISO 9612:2000