{"lab":{"_id":"69ad52a4de79e566650fd418","accr_number":"1467","country":"CZ","accr_body":"ČIA","address":"Jiráskova 259, 340 12 Švihov","categories":["environment"],"city":"Švihov","imported_at":"2026-03-08T10:42:44.590Z","methods_count":14,"name":"Monhart Akustik s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1467_129_2025_CS.pdf","1467_129_2025_EN.pdf"],"scope_summary":"Pomiary hałasu komunikacyjnego, w środowisku pracy i poza nim, pomiary poziomu mocy akustycznej i czasu pogłosu, pomiary szkodliwych substancji chemicznych, pyłów, włókien azbestu i włókien mineralnych w powietrzu łącznie z pobieraniem próbek.","search_text":"monhart akustik s.r.o. jiráskova 259, 340 12 švihov 1467","status":"active","updated_at":"2026-03-08T14:52:12.210Z","valid_from":"","valid_until":"31-10-2028","website":"www.monhart-akustik.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.monhart-akustik.cz","map_coord":[49.481745,13.281047],"map_geo":"nominatim-street","certificate_date":"14.03.2025","certificate_no":"129/2025","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pomiary hałasu komunikacyjnego, w środowisku pracy i poza nim, pomiary poziomu mocy akustycznej i czasu pogłosu, pomiary szkodliwych substancji chemicznych, pyłów, włókien azbestu i włókien mineralnych w powietrzu łącznie z pobieraniem próbek.","en":"Measurement of traffic noise and noise in working and non-working environment, measurement of sound power level and reverberation time, measurement of chemical pollutants, dust, asbestos and mineral fibres in air including sampling.","zh":"交通噪声以及工作和非工作环境噪声的测量，声功率级和混响时间的测量，空气中化学有害物、粉尘、石棉和矿物纤维的测量（包括采样）。","cs":"Měření hluku v dopravě, v pracovním i mimopracovním prostředí, měření hladiny akustického výkonu a doby dozvuku, měření chemických škodlivin, prachu, azbestových a minerálních vláken v ovzduší včetně vzorkování."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"laboratorium badawcze František Monhart","lab_division_cs":"zkušební laboratoř František Monhart","lab_division_en":"František Monhart Testing Laboratory","lab_division_zh":"František Monhart检测实验室","lab_locations":[{"code":null,"name":"Monhart Akustik s.r.o.","street":"Jiráskova 259","postal_code":"340 12","city":"Švihov","is_hq":true,"address":"Jiráskova 259, 340 12 Švihov","site":"34012|jiráskova259"},{"code":null,"name":"Pracownia Švihov","street":"Jiráskova 259","postal_code":"340 12","city":"Švihov","is_hq":false,"address":"Jiráskova 259, 340 12 Švihov","site":"34012|jiráskova259"},{"code":null,"name":"Pracownia Pilzno","street":"Teslova 1202/3","postal_code":"301 00","city":"Plzeň","is_hq":false,"address":"Teslova 1202/3, 301 00 Plzeň","site":"30100|teslova1202/3"}],"lab_locations_en":[{"code":null,"name":"Monhart Akustik s.r.o.","street":"Jiráskova 259","postal_code":"340 12","city":"Švihov","is_hq":true,"address":"Jiráskova 259, 340 12 Švihov","site":"34012|jiráskova259"},{"code":null,"name":"Švihov site","street":"Jiráskova 259","postal_code":"340 12","city":"Švihov","is_hq":false,"address":"Jiráskova 259, 340 12 Švihov","site":"34012|jiráskova259"},{"code":null,"name":"Plzeň site","street":"Teslova 1202/3","postal_code":"301 00","city":"Plzeň","is_hq":false,"address":"Teslova 1202/3, 301 00 Plzeň","site":"30100|teslova1202/3"}],"lab_locations_zh":[{"code":null,"name":"Monhart Akustik s.r.o.","street":"Jiráskova 259","postal_code":"340 12","city":"Švihov","is_hq":true,"address":"Jiráskova 259, 340 12 Švihov","site":"34012|jiráskova259"},{"code":null,"name":"Švihov工作场所","street":"Jiráskova 259","postal_code":"340 12","city":"Švihov","is_hq":false,"address":"Jiráskova 259, 340 12 Švihov","site":"34012|jiráskova259"},{"code":null,"name":"比尔森工作场所","street":"Teslova 1202/3","postal_code":"301 00","city":"Plzeň","is_hq":false,"address":"Teslova 1202/3, 301 00 Plzeň","site":"30100|teslova1202/3"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[{"pl":"Szczegółowe informacje o działalności w zakresie akredytacji (oznaczane anality) podano w części „Upřesnění rozsahu akreditace” (doprecyzowanie zakresu akredytacji).","en":"Detailed information on activities within the scope of accreditation (analytes determined) is given in the section “Upřesnění rozsahu akreditace” (specification of the scope of accreditation).","zh":"认可范围内活动的详细信息（测定的分析物）见“认可范围说明”部分。","cs":"Detailní informace k činnostem v rozsahu akreditace (stanovované analyty) jsou uvedeny v části „Upřesnění rozsahu akreditace“."}],"source_lang":"cs","source_pdf_sha256":"58e806adbd5414e408830338ee02ea702cac15fd89d5d9a2b8ba99c28affe1fb","source_pdf_url":"https://www.cai.cz/OA/pdf/P129_2025_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"8d9c50aa2500ec5c448acabd","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"1","test_object":"Środowisko poza miejscem pracy (środowisko zewnętrzne, wnętrza budynków, komunikacja)","test_object_en":"Non-working environment (outdoor environment, building interiors, traffic)","test_object_zh":"非工作环境（室外环境、建筑物内部、交通）","test_object_cs":"Mimopracovní prostředí (venkovní prostředí, interiéry budov, doprava)","methodology":"Pomiar hałasu","methodology_en":"Noise measurement","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, částka 11/2017","norm_bases":["ČSN ISO 1996-1","ČSN ISO 1996-2","Věstník MZ ČR, částka 11/2017"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko poza miejscem pracy (środowisko zewnętrzne, wnętrza budynków, komunikacja) Pomiar hałasu Mimopracovní prostředí (venkovní prostředí, interiéry budov, doprava) Měření hluku ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, částka 11/2017 Srodowisko poza miejscem pracy (srodowisko zewnetrzne, wnetrza budynkow, komunikacja) Pomiar halasu Mimopracovni prostredi (venkovni prostredi, interiery budov, doprava) Mereni hluku CSN ISO 1996-1; CSN ISO 1996-2; Vestnik MZ CR, castka 11/2017","search_en":"Non-working environment (outdoor environment, building interiors, traffic) Noise measurement ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, částka 11/2017","search_zh":"非工作环境（室外环境、建筑物内部、交通） 噪声测量 ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, částka 11/2017","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"758d439f5ae4c629a28a321e","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"2","test_object":"Środowisko pracy","test_object_en":"Working environment","test_object_zh":"工作环境","test_object_cs":"Pracovní prostředí","methodology":"Pomiar hałasu","methodology_en":"Noise measurement","methodology_zh":"噪声测量","methodology_cs":"Měření hluku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar hałasu","reference":"SOP 1 (ČSN EN ISO 9612; ČSN ISO 9612:2000; HEM-300-26.4.01-16344)","norm_bases":["SOP 1","ČSN EN ISO 9612","ČSN ISO 9612:2000","HEM-300-26.4.01-16344"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Środowisko pracy Pomiar hałasu Pracovní prostředí Měření hluku SOP 1 (ČSN EN ISO 9612; ČSN ISO 9612:2000; HEM-300-26.4.01-16344) Srodowisko pracy Pomiar halasu Pracovni prostredi Mereni hluku SOP 1 (CSN EN ISO 9612; CSN ISO 9612:2000; HEM-300-26.4.01-16344)","search_en":"Working environment Noise measurement SOP 1 (ČSN EN ISO 9612; ČSN ISO 9612:2000; HEM-300-26.4.01-16344)","search_zh":"工作环境 噪声测量 SOP 1 (ČSN EN ISO 9612; ČSN ISO 9612:2000; HEM-300-26.4.01-16344)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09855b1ee9196d1167051fc8","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"3","test_object":"Powietrze na stanowiskach pracy i powietrze wewnętrzne","test_object_en":"Workplace and indoor air","test_object_zh":"工作场所空气和室内空气","test_object_cs":"Pracovní a vnitřní ovzduší","methodology":"Oznaczanie stężenia gazów i par obliczeniowo z wyników pomiarów","methodology_en":"Determination of concentration of gases and vapours by calculation from measured values","methodology_zh":"由测量值计算测定气体和蒸气浓度","methodology_cs":"Stanovení koncentrace plynů a par výpočtem z naměřených hodnot","parameters":[{"name":"lotne związki organiczne","range":""},{"name":"metale","range":""},{"name":"aldehydy","range":""},{"name":"benzyny","range":""},{"name":"kwasy mineralne","range":""},{"name":"amoniak","range":""},{"name":"oleje mineralne","range":""},{"name":"ditlenek krzemu (SiO2)","range":""},{"name":"ozon","range":""}],"parameters_en":[{"name":"volatile organic compounds","range":""},{"name":"metals","range":""},{"name":"aldehydes","range":""},{"name":"petrol (gasolines)","range":""},{"name":"mineral acids","range":""},{"name":"ammonia","range":""},{"name":"mineral oils","range":""},{"name":"silicon dioxide (SiO2)","range":""},{"name":"ozone","range":""}],"parameters_zh":[{"name":"挥发性有机物","range":""},{"name":"金属","range":""},{"name":"醛类","range":""},{"name":"汽油","range":""},{"name":"无机酸","range":""},{"name":"氨","range":""},{"name":"矿物油","range":""},{"name":"二氧化硅（SiO2）","range":""},{"name":"臭氧","range":""}],"parameters_cs":[{"name":"těkavé organické látky","range":""},{"name":"kovy","range":""},{"name":"aldehydy","range":""},{"name":"benziny","range":""},{"name":"minerální kyseliny","range":""},{"name":"amoniak","range":""},{"name":"minerální oleje","range":""},{"name":"SiO2","range":""},{"name":"ozón","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia gazów i par obliczeniowo z wyników pomiarów\nZakres:\nlotne związki organiczne\nmetale\naldehydy\nbenzyny\nkwasy mineralne\namoniak\noleje mineralne\nditlenek krzemu (SiO2)\nozon","reference":"SOP 3 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.)","norm_bases":["SOP 3","Nařízení vlády 361/2007 Sb.","ČSN EN 689+AC","Vyhláška č. 6/2003 Sb."],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"laboratory determination of analytes in the collected sample is performed by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测提供方在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Powietrze na stanowiskach pracy i powietrze wewnętrzne Oznaczanie stężenia gazów i par obliczeniowo z wyników pomiarów lotne związki organiczne  metale  aldehydy  benzyny  kwasy mineralne  amoniak  oleje mineralne  ditlenek krzemu (SiO2)  ozon  Pracovní a vnitřní ovzduší Stanovení koncentrace plynů a par výpočtem z naměřených hodnot těkavé organické látky  kovy  aldehydy  benziny  minerální kyseliny  amoniak  minerální oleje  SiO2  ozón  SOP 3 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.) Powietrze na stanowiskach pracy i powietrze wewnetrzne Oznaczanie stezenia gazow i par obliczeniowo z wynikow pomiarow lotne zwiazki organiczne  metale  aldehydy  benzyny  kwasy mineralne  amoniak  oleje mineralne  ditlenek krzemu (SiO2)  ozon  Pracovni a vnitrni ovzdusi Stanoveni koncentrace plynu a par vypoctem z namerenych hodnot tekave organicke latky  kovy  aldehydy  benziny  mineralni kyseliny  amoniak  mineralni oleje  SiO2  ozon  SOP 3 (Narizeni vlady 361/2007 Sb.; CSN EN 689+AC; Vyhlaska c. 6/2003 Sb.)","search_en":"Workplace and indoor air Determination of concentration of gases and vapours by calculation from measured values volatile organic compounds  metals  aldehydes  petrol (gasolines)  mineral acids  ammonia  mineral oils  silicon dioxide (SiO2)  ozone  SOP 3 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.)","search_zh":"工作场所空气和室内空气 由测量值计算测定气体和蒸气浓度 挥发性有机物  金属  醛类  汽油  无机酸  氨  矿物油  二氧化硅（SiO2）  臭氧  SOP 3 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d2477b2f23de21513b11d132","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"4","test_object":"Powietrze na stanowiskach pracy i powietrze wewnętrzne","test_object_en":"Workplace and indoor air","test_object_zh":"工作场所空气和室内空气","test_object_cs":"Pracovní a vnitřní ovzduší","methodology":"Oznaczanie stężenia masowego frakcji wdychalnej i respirabilnej pyłu zawieszonego oraz stężenia liczbowego włókien mineralnych i azbestu obliczeniowo z wyników pomiarów","methodology_en":"Determination of mass concentration of inhalable and respirable fractions of airborne dust and number concentration of mineral and asbestos fibres by calculation from measured values","methodology_zh":"由测量值计算测定飘尘可吸入和可呼吸部分的质量浓度以及矿物纤维和石棉纤维的数量浓度","methodology_cs":"Stanovení hmotnostní koncentrace vdechovatelné a respirabilní frakce polétavého prachu a početní koncentrace minerálních a azbestových vláken výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie stężenia masowego frakcji wdychalnej i respirabilnej pyłu zawieszonego oraz stężenia liczbowego włókien mineralnych i azbestu obliczeniowo z wyników pomiarów","reference":"SOP 4 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7)","norm_bases":["SOP 4","Nařízení vlády 361/2007 Sb.","ČSN EN 689+AC","ČSN EN 481","Vyhláška č. 6/2003 Sb.","ČSN EN ISO 16000-7"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"laboratoryjne oznaczenie analitów w pobranej próbce wykonuje zewnętrzny dostawca badań w zakresie swojej akredytacji","note_en":"laboratory determination of analytes in the collected sample is performed by an external test provider within the scope of its accreditation","note_zh":"所采样品中分析物的实验室测定由外部检测提供方在其认可范围内进行","note_cs":"laboratorní stanovení analytů v odebraném vzorku je prováděno u externího poskytovatele zkoušky v rozsahu jeho akreditace","search_text":"Powietrze na stanowiskach pracy i powietrze wewnętrzne Oznaczanie stężenia masowego frakcji wdychalnej i respirabilnej pyłu zawieszonego oraz stężenia liczbowego włókien mineralnych i azbestu obliczeniowo z wyników pomiarów Pracovní a vnitřní ovzduší Stanovení hmotnostní koncentrace vdechovatelné a respirabilní frakce polétavého prachu a početní koncentrace minerálních a azbestových vláken výpočtem z naměřených hodnot SOP 4 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7) Powietrze na stanowiskach pracy i powietrze wewnetrzne Oznaczanie stezenia masowego frakcji wdychalnej i respirabilnej pylu zawieszonego oraz stezenia liczbowego wlokien mineralnych i azbestu obliczeniowo z wynikow pomiarow Pracovni a vnitrni ovzdusi Stanoveni hmotnostni koncentrace vdechovatelne a respirabilni frakce poletaveho prachu a pocetni koncentrace mineralnich a azbestovych vlaken vypoctem z namerenych hodnot SOP 4 (Narizeni vlady 361/2007 Sb.; CSN EN 689+AC; CSN EN 481; Vyhlaska c. 6/2003 Sb.; CSN EN ISO 16000-7)","search_en":"Workplace and indoor air Determination of mass concentration of inhalable and respirable fractions of airborne dust and number concentration of mineral and asbestos fibres by calculation from measured values SOP 4 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7)","search_zh":"工作场所空气和室内空气 由测量值计算测定飘尘可吸入和可呼吸部分的质量浓度以及矿物纤维和石棉纤维的数量浓度 SOP 4 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d3d06f4519fae27c7db8e2e2","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"5","test_object":"Urządzenia maszynowe i elektryczne","test_object_en":"Machinery and electrical equipment","test_object_zh":"机械和电气设备","test_object_cs":"Strojní a elektrické zařízení","methodology":"Pomiar poziomu mocy akustycznej","methodology_en":"Measurement of sound power level","methodology_zh":"声功率级的测量","methodology_cs":"Měření hladiny akustického výkonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu mocy akustycznej","reference":"ČSN EN ISO 3746","norm_bases":["ČSN EN ISO 3746"],"lab_section":"Pracownia Švihov","lab_section_en":"Švihov site","lab_section_zh":"Švihov工作场所","lab_section_cs":"Pracoviště Švihov","lab_address":"Jiráskova 259, 340 12 Švihov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia maszynowe i elektryczne Pomiar poziomu mocy akustycznej Strojní a elektrické zařízení Měření hladiny akustického výkonu ČSN EN ISO 3746 Urzadzenia maszynowe i elektryczne Pomiar poziomu mocy akustycznej Strojni a elektricke zarizeni Mereni hladiny akustickeho vykonu CSN EN ISO 3746","search_en":"Machinery and electrical equipment Measurement of sound power level ČSN EN ISO 3746","search_zh":"机械和电气设备 声功率级的测量 ČSN EN ISO 3746","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c5aa75d831cd209a3b2eea3b","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"5","test_object":"Urządzenia maszynowe i elektryczne","test_object_en":"Machinery and electrical equipment","test_object_zh":"机械和电气设备","test_object_cs":"Strojní a elektrické zařízení","methodology":"Pomiar poziomu mocy akustycznej","methodology_en":"Measurement of sound power level","methodology_zh":"声功率级的测量","methodology_cs":"Měření hladiny akustického výkonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu mocy akustycznej","reference":"ČSN EN ISO 3746","norm_bases":["ČSN EN ISO 3746"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Urządzenia maszynowe i elektryczne Pomiar poziomu mocy akustycznej Strojní a elektrické zařízení Měření hladiny akustického výkonu ČSN EN ISO 3746 Urzadzenia maszynowe i elektryczne Pomiar poziomu mocy akustycznej Strojni a elektricke zarizeni Mereni hladiny akustickeho vykonu CSN EN ISO 3746","search_en":"Machinery and electrical equipment Measurement of sound power level ČSN EN ISO 3746","search_zh":"机械和电气设备 声功率级的测量 ČSN EN ISO 3746","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c9cad33150cbb8bad679da0e","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"6","test_object":"Transformatory","test_object_en":"Transformers","test_object_zh":"变压器","test_object_cs":"Transformátory","methodology":"Pomiar poziomu mocy akustycznej","methodology_en":"Measurement of sound power level","methodology_zh":"声功率级的测量","methodology_cs":"Měření hladiny akustického výkonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu mocy akustycznej","reference":"ČSN EN 60076-10 ed. 2, mimo čl. 11.3","norm_bases":["ČSN EN 60076-10 ed. 2"],"lab_section":"Pracownia Švihov","lab_section_en":"Švihov site","lab_section_zh":"Švihov工作场所","lab_section_cs":"Pracoviště Švihov","lab_address":"Jiráskova 259, 340 12 Švihov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Transformatory Pomiar poziomu mocy akustycznej Transformátory Měření hladiny akustického výkonu ČSN EN 60076-10 ed. 2, mimo čl. 11.3 Transformatory Pomiar poziomu mocy akustycznej Transformatory Mereni hladiny akustickeho vykonu CSN EN 60076-10 ed. 2, mimo cl. 11.3","search_en":"Transformers Measurement of sound power level ČSN EN 60076-10 ed. 2, mimo čl. 11.3","search_zh":"变压器 声功率级的测量 ČSN EN 60076-10 ed. 2, mimo čl. 11.3","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ed2969d08c7c3b9851f4d77","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"6","test_object":"Transformatory","test_object_en":"Transformers","test_object_zh":"变压器","test_object_cs":"Transformátory","methodology":"Pomiar poziomu mocy akustycznej","methodology_en":"Measurement of sound power level","methodology_zh":"声功率级的测量","methodology_cs":"Měření hladiny akustického výkonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar poziomu mocy akustycznej","reference":"ČSN EN 60076-10 ed. 2, mimo čl. 11.3","norm_bases":["ČSN EN 60076-10 ed. 2"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Transformatory Pomiar poziomu mocy akustycznej Transformátory Měření hladiny akustického výkonu ČSN EN 60076-10 ed. 2, mimo čl. 11.3 Transformatory Pomiar poziomu mocy akustycznej Transformatory Mereni hladiny akustickeho vykonu CSN EN 60076-10 ed. 2, mimo cl. 11.3","search_en":"Transformers Measurement of sound power level ČSN EN 60076-10 ed. 2, mimo čl. 11.3","search_zh":"变压器 声功率级的测量 ČSN EN 60076-10 ed. 2, mimo čl. 11.3","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25b16e73dad1124f3f955e99","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"7","test_object":"Pomieszczenia zamknięte w budynkach","test_object_en":"Enclosed spaces in buildings","test_object_zh":"建筑物内的封闭空间","test_object_cs":"Uzavřené prostory ve stavbách","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间的测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2","norm_bases":["ČSN ISO 3382:1999","ČSN ISO 3382-1","CSN ISO 3382-2"],"lab_section":"Pracownia Švihov","lab_section_en":"Švihov site","lab_section_zh":"Švihov工作场所","lab_section_cs":"Pracoviště Švihov","lab_address":"Jiráskova 259, 340 12 Švihov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia zamknięte w budynkach Pomiar czasu pogłosu Uzavřené prostory ve stavbách Měření doby dozvuku ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2 Pomieszczenia zamkniete w budynkach Pomiar czasu poglosu Uzavrene prostory ve stavbach Mereni doby dozvuku CSN ISO 3382:1999; CSN ISO 3382-1; CSN ISO 3382-2","search_en":"Enclosed spaces in buildings Measurement of reverberation time ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2","search_zh":"建筑物内的封闭空间 混响时间的测量 ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"236792167ff57a225319ac54","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"7","test_object":"Pomieszczenia zamknięte w budynkach","test_object_en":"Enclosed spaces in buildings","test_object_zh":"建筑物内的封闭空间","test_object_cs":"Uzavřené prostory ve stavbách","methodology":"Pomiar czasu pogłosu","methodology_en":"Measurement of reverberation time","methodology_zh":"混响时间的测量","methodology_cs":"Měření doby dozvuku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar czasu pogłosu","reference":"ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2","norm_bases":["ČSN ISO 3382:1999","ČSN ISO 3382-1","CSN ISO 3382-2"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pomieszczenia zamknięte w budynkach Pomiar czasu pogłosu Uzavřené prostory ve stavbách Měření doby dozvuku ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2 Pomieszczenia zamkniete w budynkach Pomiar czasu poglosu Uzavrene prostory ve stavbach Mereni doby dozvuku CSN ISO 3382:1999; CSN ISO 3382-1; CSN ISO 3382-2","search_en":"Enclosed spaces in buildings Measurement of reverberation time ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2","search_zh":"建筑物内的封闭空间 混响时间的测量 ČSN ISO 3382:1999; ČSN ISO 3382-1; CSN ISO 3382-2","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2e73a5bf3ca88962d3c4f918","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"8","test_object":"Przegrody ścienne i stropowe w budynkach","test_object_en":"Wall and floor constructions in buildings","test_object_zh":"建筑物中的墙体和楼板构造","test_object_cs":"Stěnové a podlahové konstrukce ve stavbách","methodology":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","methodology_en":"Measurement of airborne sound insulation","methodology_zh":"空气声隔声的测量","methodology_cs":"Měření vzduchové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","reference":"ČSN EN ISO 16283-1","norm_bases":["ČSN EN ISO 16283-1"],"lab_section":"Pracownia Švihov","lab_section_en":"Švihov site","lab_section_zh":"Švihov工作场所","lab_section_cs":"Pracoviště Švihov","lab_address":"Jiráskova 259, 340 12 Švihov","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody ścienne i stropowe w budynkach Pomiar izolacyjności akustycznej od dźwięków powietrznych Stěnové a podlahové konstrukce ve stavbách Měření vzduchové neprůzvučnosti ČSN EN ISO 16283-1 Przegrody scienne i stropowe w budynkach Pomiar izolacyjnosci akustycznej od dzwiekow powietrznych Stenove a podlahove konstrukce ve stavbach Mereni vzduchove nepruzvucnosti CSN EN ISO 16283-1","search_en":"Wall and floor constructions in buildings Measurement of airborne sound insulation ČSN EN ISO 16283-1","search_zh":"建筑物中的墙体和楼板构造 空气声隔声的测量 ČSN EN ISO 16283-1","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44de384c492cb8834d06e93c","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"8","test_object":"Przegrody ścienne i stropowe w budynkach","test_object_en":"Wall and floor constructions in buildings","test_object_zh":"建筑物中的墙体和楼板构造","test_object_cs":"Stěnové a podlahové konstrukce ve stavbách","methodology":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","methodology_en":"Measurement of airborne sound insulation","methodology_zh":"空气声隔声的测量","methodology_cs":"Měření vzduchové neprůzvučnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar izolacyjności akustycznej od dźwięków powietrznych","reference":"ČSN EN ISO 16283-1","norm_bases":["ČSN EN ISO 16283-1"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Przegrody ścienne i stropowe w budynkach Pomiar izolacyjności akustycznej od dźwięków powietrznych Stěnové a podlahové konstrukce ve stavbách Měření vzduchové neprůzvučnosti ČSN EN ISO 16283-1 Przegrody scienne i stropowe w budynkach Pomiar izolacyjnosci akustycznej od dzwiekow powietrznych Stenove a podlahove konstrukce ve stavbach Mereni vzduchove nepruzvucnosti CSN EN ISO 16283-1","search_en":"Wall and floor constructions in buildings Measurement of airborne sound insulation ČSN EN ISO 16283-1","search_zh":"建筑物中的墙体和楼板构造 空气声隔声的测量 ČSN EN ISO 16283-1","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"614753110cfe01775cee1ea2","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"1","test_object":"Powietrze na stanowiskach pracy i powietrze wewnętrzne","test_object_en":"Workplace and indoor air","test_object_zh":"工作场所空气和室内空气","test_object_cs":"Pracovní a vnitřní ovzduší","methodology":"Pobieranie próbek gazów i par przez sorpcję na sorbencie stałym lub wychwyt na filtrze","methodology_en":"Sampling of gases and vapours by sorption on a solid sorbent or trapping on a filter","methodology_zh":"固体吸附剂吸附或滤膜捕集法采集气体和蒸气样品","methodology_cs":"Vzorkování plynů a par sorpcí na pevný sorbent nebo záchytem na filtr","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek gazów i par przez sorpcję na sorbencie stałym lub wychwyt na filtrze","reference":"SOP V1 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.)","norm_bases":["SOP V1","Nařízení vlády 361/2007 Sb.","ČSN EN 689+AC","Vyhláška č. 6/2003 Sb."],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy i powietrze wewnętrzne Pobieranie próbek gazów i par przez sorpcję na sorbencie stałym lub wychwyt na filtrze Pracovní a vnitřní ovzduší Vzorkování plynů a par sorpcí na pevný sorbent nebo záchytem na filtr SOP V1 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.) Powietrze na stanowiskach pracy i powietrze wewnetrzne Pobieranie probek gazow i par przez sorpcje na sorbencie stalym lub wychwyt na filtrze Pracovni a vnitrni ovzdusi Vzorkovani plynu a par sorpci na pevny sorbent nebo zachytem na filtr SOP V1 (Narizeni vlady 361/2007 Sb.; CSN EN 689+AC; Vyhlaska c. 6/2003 Sb.)","search_en":"Workplace and indoor air Sampling of gases and vapours by sorption on a solid sorbent or trapping on a filter SOP V1 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.)","search_zh":"工作场所空气和室内空气 固体吸附剂吸附或滤膜捕集法采集气体和蒸气样品 SOP V1 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; Vyhláška č. 6/2003 Sb.)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ab55922b24c76788274eb2a","lab_id":"69ad52a4de79e566650fd418","country":"CZ","accr_number":"1467","accr_body":"ČIA","row_label":"2","test_object":"Powietrze na stanowiskach pracy i powietrze wewnętrzne","test_object_en":"Workplace and indoor air","test_object_zh":"工作场所空气和室内空气","test_object_cs":"Pracovní a vnitřní ovzduší","methodology":"Pobieranie na filtr próbek frakcji wdychalnej i respirabilnej pyłu zawieszonego oraz włókien mineralnych i azbestu","methodology_en":"Sampling of inhalable and respirable fractions of airborne dust and mineral and asbestos fibres on a filter","methodology_zh":"滤膜采集飘尘可吸入和可呼吸部分以及矿物纤维和石棉纤维样品","methodology_cs":"Vzorkování vdechovatelné a respirabilní frakce polétavého prachu a minerálních a azbestových vláken na filtr","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie na filtr próbek frakcji wdychalnej i respirabilnej pyłu zawieszonego oraz włókien mineralnych i azbestu","reference":"SOP V2 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7)","norm_bases":["SOP V2","Nařízení vlády 361/2007 Sb.","ČSN EN 689+AC","ČSN EN 481","Vyhláška č. 6/2003 Sb.","ČSN EN ISO 16000-7"],"lab_section":"Pracownia Pilzno","lab_section_en":"Plzeň site","lab_section_zh":"比尔森工作场所","lab_section_cs":"Pracoviště Plzeň","lab_address":"Teslova 1202/3, 301 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze na stanowiskach pracy i powietrze wewnętrzne Pobieranie na filtr próbek frakcji wdychalnej i respirabilnej pyłu zawieszonego oraz włókien mineralnych i azbestu Pracovní a vnitřní ovzduší Vzorkování vdechovatelné a respirabilní frakce polétavého prachu a minerálních a azbestových vláken na filtr SOP V2 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7) Powietrze na stanowiskach pracy i powietrze wewnetrzne Pobieranie na filtr probek frakcji wdychalnej i respirabilnej pylu zawieszonego oraz wlokien mineralnych i azbestu Pracovni a vnitrni ovzdusi Vzorkovani vdechovatelne a respirabilni frakce poletaveho prachu a mineralnich a azbestovych vlaken na filtr SOP V2 (Narizeni vlady 361/2007 Sb.; CSN EN 689+AC; CSN EN 481; Vyhlaska c. 6/2003 Sb.; CSN EN ISO 16000-7)","search_en":"Workplace and indoor air Sampling of inhalable and respirable fractions of airborne dust and mineral and asbestos fibres on a filter SOP V2 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7)","search_zh":"工作场所空气和室内空气 滤膜采集飘尘可吸入和可呼吸部分以及矿物纤维和石棉纤维样品 SOP V2 (Nařízení vlády 361/2007 Sb.; ČSN EN 689+AC; ČSN EN 481; Vyhláška č. 6/2003 Sb.; ČSN EN ISO 16000-7)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}