🇨🇿 Český hydrometeorologický ústav PL
Environment
Český hydrometeorologický ústav is a laboratory accredited by ČIA under number 1460 (Praha 4, Czech Republic). Its accreditation scope covers 84 test methods in the following areas: Environment. Test objects include: Ambient air (immissions), Precipitation water. Most frequently used techniques: automatic analysers, gas chromatography with photo-ionisation detec…, automatic analysers, non-dispersive infrared spectrometry, automatic beta and optical dust monitors.
At a glance
- Accreditation number: ČIA 1460
- Methods in scope: 84
- Types of test objects: 2
- Techniques used: 15
- City: Praha 4, Czech Republic
- Valid until: 23-06-2028
- Accreditation number
- 1460
- Accreditation body
- ČIA
- Address
- Generála Šišky 942, Libuš, 143 00 Praha 4
- City
- Praha 4, Czech Republic
- Division
- Monitoring Imisji
- Valid until
- 23-06-2028
What this laboratory tests (2)
- Ambient air (immissions) — 72 methods
- Precipitation water — 12 methods
Analytical techniques used (15)
- automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) — 6 methods
- automatic analysers, non-dispersive infrared spectrometry — 6 methods
- automatic beta and optical dust monitors — 6 methods
- automatic chemiluminescence analysers — 6 methods
- automatic fluorescence analysers — 6 methods
- automatic ultraviolet photometric analysers — 6 methods
- gravimetric method — 4 methods
- gas chromatography with flame ionisation detector (GC-FID) — 2 methods
- inductively coupled plasma mass spectrometry (ICP-MS) — 2 methods
- spectrophotometric method — 2 methods
- atomic absorption spectroscopy (AAS) — 1 method
- direct conductometry — 1 method
- gas chromatography – mass spectrometry (GC-MS) — 1 method
- ion chromatography — 1 method
- potentiometric method — 1 method
Laboratory sections (6)
- Immission monitoring, CLI – ČHMÚ Prague — 24 methods
- Immission monitoring, P – ČHMÚ Ústí nad Labem — 13 methods
- Immission monitoring, P – ČHMÚ Brno — 12 methods
- Immission monitoring, P – ČHMÚ Ostrava — 12 methods
- Immission monitoring, P – ČHMÚ Plzeň — 12 methods
- Immission monitoring, P – ČHMÚ Hradec Králové — 11 methods
Laboratory locations
- Monitoring imisji, CLI – ČHMÚ Praga — Generála Šišky 942, Libuš
- Monitoring imisji, P – ČHMÚ Ústí nad Labem — Kočkovská 2699/18
- Monitoring imisji, P – ČHMÚ Ostrawa — K Myslivně 2182/3
- Monitoring imisji, P – ČHMÚ Brno — Kroftova 2578/43
- Monitoring imisji, P – ČHMÚ Hradec Králové — Dvorská 410/102
- Monitoring imisji, P – ČHMÚ Pilzno — Mozartova 1237/41
Certificate information
- Certificate date
- 23.06.2023
Accreditation scope — test methods (84)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Immission monitoring, CLI – ČHMÚ Prague | |||||
| 1 | Precipitation water | Determination of pH by potentiometry Regulated area: Tests |
potentiometric method | T 21 AA-001 (ČSN ISO 10523) | |
| 2 | Precipitation water | Determination of electrical conductivity by direct conductometry Regulated area: Tests |
direct conductometry | T 21 AA-002 (ČSN EN 27888) | |
| 3 | Ambient air (immissions) | Determination of volatile organic compounds (VOC) by GC-FID Regulated area: Tests |
gas chromatography with flame ionisation detector (GC-FID) | T 21 AA-003 (EPA Methods: Method TO14) | |
| 4 | Ambient air (immissions) | Determination of Ni, As, Cd and Pb by ICP-MS Nickel (Ni) Arsenic (As) Cadmium (Cd) Lead (Pb) Regulated area: Tests |
inductively coupled plasma mass spectrometry (ICP-MS) | T 21 AA-005 (EMEP manual for sampling and chemical analysis; ČSN EN 14902) | |
| 5 | Precipitation water | Determination of F-, Cl-, NO3- and SO42- by ion chromatography fluoride (F-) chloride (Cl-) nitrate (NO3-) sulphate (SO42-) Regulated area: Tests |
ion chromatography | T 21 AA-008 (ČSN ISO 10304-1) | |
| 6 | Ambient air (immissions) | Determination of gaseous ammonia and ammonium ions by spectrophotometric method, expressed as the sum of ammonium ions Regulated area: Tests |
spectrophotometric method | T 21 AA-014 (ČSN ISO 15923-1) | |
| 7 | Ambient air (immissions) | Gravimetric determination of aerosol particles (PM10 and PM2.5) Regulated area: Tests |
gravimetric method | T 21 AA-015 (ČSN EN 12341) | |
| 8 | Precipitation water | Determination of Ca, Mg, Na, K by AAS Calcium (Ca) Magnesium (Mg) Sodium (Na) Potassium (K) Regulated area: Tests |
atomic absorption spectroscopy (AAS) | T 21 AA-016 (EMEP manual for sampling and chemical analysis) | |
| 9 | Precipitation water | Determination of Ni, As, Cd and Pb by ICP-MS Nickel (Ni) Arsenic (As) Cadmium (Cd) Lead (Pb) Regulated area: Tests |
inductively coupled plasma mass spectrometry (ICP-MS) | T 21 AA-017 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) | |
| 10 | Ambient air (immissions) | Determination of benzene by GC-FID Regulated area: Tests |
gas chromatography with flame ionisation detector (GC-FID) | T 21 AA-019 (ČSN EN ISO 16017-1; ČSN EN ISO 16017-2) | |
| 11 | Precipitation water | Determination of ammonium ions by spectrophotometric method Regulated area: Tests |
spectrophotometric method | T 21 AA-020 (ČSN ISO 15923-1) | |
| 12 | Ambient air (immissions) | Determination of SO2 by automatic fluorescence analysers Regulated area: Tests |
automatic fluorescence analysers | T 22 AA-001 (ČSN EN 14212) | |
| 13 | Ambient air (immissions) | Determination of NO, NO2, NOx by automatic chemiluminescence analysers nitrogen monoxide (NO) nitrogen dioxide (NO2) nitrogen oxides (NOx) Regulated area: Tests |
automatic chemiluminescence analysers | T 22 AA-002 (ČSN EN 14211) | |
| 14 | Ambient air (immissions) | Determination of CO by automatic analysers using non-dispersive infrared spectrometry Regulated area: Tests |
automatic analysers, non-dispersive infrared spectrometry | T 22 AA-004 (ČSN EN 14626) | |
| 15 | Ambient air (immissions) | Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors Regulated area: Tests |
automatic beta and optical dust monitors | T 22 AA-005 (ČSN EN 16450) | |
| 16 | Ambient air (immissions) | Determination of benzene and toluene by automatic analysers using GC-PID Regulated area: Tests |
automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) | T 22 AA-007 (ČSN EN 14662-3) | |
| 17 | Ambient air (immissions) | Determination of O3 by automatic ultraviolet photometric analysers Regulated area: Tests |
automatic ultraviolet photometric analysers | T 22 AA-010 (ČSN EN 14625) | |
| 18 | Ambient air (immissions) | Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler Regulated area: Sampling |
T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) | ||
| 19 | Ambient air (immissions) | Sampling of ambient air into a canister for determination of volatile organic compounds (VOC) (manual sampling) Regulated area: Sampling |
T 21 AA-023 (EPA Methods: Method TO14) | ||
| 20 | Ambient air (immissions) | Sampling of ambient air onto filters for determination of gaseous nitric acid, gaseous ammonia and nitrate, sulphate and ammonium ions with an automatic sampler Regulated area: Sampling |
T 21 AA-024 (EMEP manual for sampling and chemical analysis) | ||
| 21 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) Regulated area: Sampling |
T 21 AA-026 (ČSN EN ISO 16017-2) | ||
| 22 | Ambient air (immissions) | Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler Regulated area: Sampling |
T 21 AA-027 (ČSN EN 12341) | ||
| 23 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler Regulated area: Sampling |
T 21 AA-028 (ČSN EN ISO 16017-1) | ||
| 24 | Precipitation water | Sampling of "wet-only" precipitation water with an automatic sampler (precipitation collector) Regulated area: Sampling |
T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) | ||
| Immission monitoring, P – ČHMÚ Ústí nad Labem | |||||
| 25 | Ambient air (immissions) | Determination of polycyclic aromatic hydrocarbons by GC-MS Regulated area: Tests |
gas chromatography – mass spectrometry (GC-MS) | T 21 AA-009 (ČSN EN 15549; ČSN P CEN/TS 16645; ISO 12884) | |
| 26 | Ambient air (immissions) | Gravimetric determination of aerosol particles (PM10 and PM2.5) Regulated area: Tests |
gravimetric method | T 21 AA-015 (ČSN EN 12341) | |
| 27 | Ambient air (immissions) | Determination of SO2 by automatic fluorescence analysers Regulated area: Tests |
automatic fluorescence analysers | T 22 AA-001 (ČSN EN 14212) | |
| 28 | Ambient air (immissions) | Determination of NO, NO2, NOx by automatic chemiluminescence analysers nitrogen monoxide (NO) nitrogen dioxide (NO2) nitrogen oxides (NOx) Regulated area: Tests |
automatic chemiluminescence analysers | T 22 AA-002 (ČSN EN 14211) | |
| 29 | Ambient air (immissions) | Determination of CO by automatic analysers using non-dispersive infrared spectrometry Regulated area: Tests |
automatic analysers, non-dispersive infrared spectrometry | T 22 AA-004 (ČSN EN 14626) | |
| 30 | Ambient air (immissions) | Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors Regulated area: Tests |
automatic beta and optical dust monitors | T 22 AA-005 (ČSN EN 16450) | |
| 31 | Ambient air (immissions) | Determination of benzene and toluene by automatic analysers using GC-PID Regulated area: Tests |
automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) | T 22 AA-007 (ČSN EN 14662-3) | |
| 32 | Ambient air (immissions) | Determination of O3 by automatic ultraviolet photometric analysers Regulated area: Tests |
automatic ultraviolet photometric analysers | T 22 AA-010 (ČSN EN 14625) | |
| 33 | Ambient air (immissions) | Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler Regulated area: Sampling |
T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) | ||
| 34 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) Regulated area: Sampling |
T 21 AA-026 (ČSN EN ISO 16017-2) | ||
| 35 | Ambient air (immissions) | Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler Regulated area: Sampling |
T 21 AA-027 (ČSN EN 12341) | ||
| 36 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler Regulated area: Sampling |
T 21 AA-028 (ČSN EN ISO 16017-1) | ||
| 37 | Precipitation water | Sampling of "wet-only" precipitation water with an automatic sampler (precipitation collector) Regulated area: Sampling |
T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) | ||
| Immission monitoring, P – ČHMÚ Ostrava | |||||
| 38 | Ambient air (immissions) | Gravimetric determination of aerosol particles (PM10 and PM2.5) Regulated area: Tests |
gravimetric method | T 21 AA-015 (ČSN EN 12341) | |
| 39 | Ambient air (immissions) | Determination of SO2 by automatic fluorescence analysers Regulated area: Tests |
automatic fluorescence analysers | T 22 AA-001 (ČSN EN 14212) | |
| 40 | Ambient air (immissions) | Determination of NO, NO2, NOx by automatic chemiluminescence analysers nitrogen monoxide (NO) nitrogen dioxide (NO2) nitrogen oxides (NOx) Regulated area: Tests |
automatic chemiluminescence analysers | T 22 AA-002 (ČSN EN 14211) | |
| 41 | Ambient air (immissions) | Determination of CO by automatic analysers using non-dispersive infrared spectrometry Regulated area: Tests |
automatic analysers, non-dispersive infrared spectrometry | T 22 AA-004 (ČSN EN 14626) | |
| 42 | Ambient air (immissions) | Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors Regulated area: Tests |
automatic beta and optical dust monitors | T 22 AA-005 (ČSN EN 16450) | |
| 43 | Ambient air (immissions) | Determination of benzene and toluene by automatic analysers using GC-PID Regulated area: Tests |
automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) | T 22 AA-007 (ČSN EN 14662-3) | |
| 44 | Ambient air (immissions) | Determination of O3 by automatic ultraviolet photometric analysers Regulated area: Tests |
automatic ultraviolet photometric analysers | T 22 AA-010 (ČSN EN 14625) | |
| 45 | Ambient air (immissions) | Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler Regulated area: Sampling |
T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) | ||
| 46 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) Regulated area: Sampling |
T 21 AA-026 (ČSN EN ISO 16017-2) | ||
| 47 | Ambient air (immissions) | Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler Regulated area: Sampling |
T 21 AA-027 (ČSN EN 12341) | ||
| 48 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler Regulated area: Sampling |
T 21 AA-028 (ČSN EN ISO 16017-1) | ||
| 49 | Precipitation water | Sampling of "wet-only" precipitation water with an automatic sampler (precipitation collector) Regulated area: Sampling |
T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) | ||
| Immission monitoring, P – ČHMÚ Brno | |||||
| 50 | Ambient air (immissions) | Gravimetric determination of aerosol particles (PM10 and PM2.5) Regulated area: Tests |
gravimetric method | T 21 AA-015 (ČSN EN 12341) | |
| 51 | Ambient air (immissions) | Determination of SO2 by automatic fluorescence analysers Regulated area: Tests |
automatic fluorescence analysers | T 22 AA-001 (ČSN EN 14212) | |
| 52 | Ambient air (immissions) | Determination of NO, NO2, NOx by automatic chemiluminescence analysers nitrogen monoxide (NO) nitrogen dioxide (NO2) nitrogen oxides (NOx) Regulated area: Tests |
automatic chemiluminescence analysers | T 22 AA-002 (ČSN EN 14211) | |
| 53 | Ambient air (immissions) | Determination of CO by automatic analysers using non-dispersive infrared spectrometry Regulated area: Tests |
automatic analysers, non-dispersive infrared spectrometry | T 22 AA-004 (ČSN EN 14626) | |
| 54 | Ambient air (immissions) | Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors Regulated area: Tests |
automatic beta and optical dust monitors | T 22 AA-005 (ČSN EN 16450) | |
| 55 | Ambient air (immissions) | Determination of benzene and toluene by automatic analysers using GC-PID Regulated area: Tests |
automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) | T 22 AA-007 (ČSN EN 14662-3) | |
| 56 | Ambient air (immissions) | Determination of O3 by automatic ultraviolet photometric analysers Regulated area: Tests |
automatic ultraviolet photometric analysers | T 22 AA-010 (ČSN EN 14625) | |
| 57 | Ambient air (immissions) | Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler Regulated area: Sampling |
T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) | ||
| 58 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) Regulated area: Sampling |
T 21 AA-026 (ČSN EN ISO 16017-2) | ||
| 59 | Ambient air (immissions) | Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler Regulated area: Sampling |
T 21 AA-027 (ČSN EN 12341) | ||
| 60 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler Regulated area: Sampling |
T 21 AA-028 (ČSN EN ISO 16017-1) | ||
| 61 | Precipitation water | Sampling of "wet-only" precipitation water with an automatic sampler (precipitation collector) Regulated area: Sampling |
T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) | ||
| Immission monitoring, P – ČHMÚ Hradec Králové | |||||
| 62 | Ambient air (immissions) | Determination of SO2 by automatic fluorescence analysers Regulated area: Tests |
automatic fluorescence analysers | T 22 AA-001 (ČSN EN 14212) | |
| 63 | Ambient air (immissions) | Determination of NO, NO2, NOx by automatic chemiluminescence analysers nitrogen monoxide (NO) nitrogen dioxide (NO2) nitrogen oxides (NOx) Regulated area: Tests |
automatic chemiluminescence analysers | T 22 AA-002 (ČSN EN 14211) | |
| 64 | Ambient air (immissions) | Determination of CO by automatic analysers using non-dispersive infrared spectrometry Regulated area: Tests |
automatic analysers, non-dispersive infrared spectrometry | T 22 AA-004 (ČSN EN 14626) | |
| 65 | Ambient air (immissions) | Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors Regulated area: Tests |
automatic beta and optical dust monitors | T 22 AA-005 (ČSN EN 16450) | |
| 66 | Ambient air (immissions) | Determination of benzene and toluene by automatic analysers using GC-PID Regulated area: Tests |
automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) | T 22 AA-007 (ČSN EN 14662-3) | |
| 67 | Ambient air (immissions) | Determination of O3 by automatic ultraviolet photometric analysers Regulated area: Tests |
automatic ultraviolet photometric analysers | T 22 AA-010 (ČSN EN 14625) | |
| 68 | Ambient air (immissions) | Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler Regulated area: Sampling |
T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) | ||
| 69 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) Regulated area: Sampling |
T 21 AA-026 (ČSN EN ISO 16017-2) | ||
| 70 | Ambient air (immissions) | Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler Regulated area: Sampling |
T 21 AA-027 (ČSN EN 12341) | ||
| 71 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler Regulated area: Sampling |
T 21 AA-028 (ČSN EN ISO 16017-1) | ||
| 72 | Precipitation water | Sampling of "wet-only" precipitation water with an automatic sampler (precipitation collector) Regulated area: Sampling |
T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) | ||
| Immission monitoring, P – ČHMÚ Plzeň | |||||
| 73 | Ambient air (immissions) | Determination of SO2 by automatic fluorescence analysers Regulated area: Tests |
automatic fluorescence analysers | T 22 AA-001 (ČSN EN 14212) | |
| 74 | Ambient air (immissions) | Determination of NO, NO2, NOx by automatic chemiluminescence analysers nitrogen monoxide (NO) nitrogen dioxide (NO2) nitrogen oxides (NOx) Regulated area: Tests |
automatic chemiluminescence analysers | T 22 AA-002 (ČSN EN 14211) | |
| 75 | Ambient air (immissions) | Determination of CO by automatic analysers using non-dispersive infrared spectrometry Regulated area: Tests |
automatic analysers, non-dispersive infrared spectrometry | T 22 AA-004 (ČSN EN 14626) | |
| 76 | Ambient air (immissions) | Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors Regulated area: Tests |
automatic beta and optical dust monitors | T 22 AA-005 (ČSN EN 16450) | |
| 77 | Ambient air (immissions) | Determination of benzene and toluene by automatic analysers using GC-PID Regulated area: Tests |
automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) | T 22 AA-007 (ČSN EN 14662-3) | |
| 78 | Ambient air (immissions) | Determination of O3 by automatic ultraviolet photometric analysers Regulated area: Tests |
automatic ultraviolet photometric analysers | T 22 AA-010 (ČSN EN 14625) | |
| 79 | Ambient air (immissions) | Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler Regulated area: Sampling |
T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) | ||
| 80 | Ambient air (immissions) | Sampling of ambient air onto filters for determination of gaseous nitric acid, gaseous ammonia and nitrate, sulphate and ammonium ions with an automatic sampler Regulated area: Sampling |
T 21 AA-024 (EMEP manual for sampling and chemical analysis) | ||
| 81 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) Regulated area: Sampling |
T 21 AA-026 (ČSN EN ISO 16017-2) | ||
| 82 | Ambient air (immissions) | Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler Regulated area: Sampling |
T 21 AA-027 (ČSN EN 12341) | ||
| 83 | Ambient air (immissions) | Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler Regulated area: Sampling |
T 21 AA-028 (ČSN EN ISO 16017-1) | ||
| 84 | Precipitation water | Sampling of "wet-only" precipitation water with an automatic sampler (precipitation collector) Regulated area: Sampling |
T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) | ||
Reference standards (45)
EMEP manual for sampling and chemical analysis
EPA Methods: Method TO14
ISO 12884
T 21 AA-001
T 21 AA-002
T 21 AA-003
T 21 AA-005
T 21 AA-008
T 21 AA-009
T 21 AA-014
T 21 AA-015
T 21 AA-016
T 21 AA-017
T 21 AA-019
T 21 AA-020
T 21 AA-022
T 21 AA-023
T 21 AA-024
T 21 AA-026
T 21 AA-027
T 21 AA-028
T 21 AA-030
T 22 AA-001
T 22 AA-002
T 22 AA-004
T 22 AA-005
T 22 AA-007
T 22 AA-010
ČSN EN 12341
ČSN EN 14211
ČSN EN 14212
ČSN EN 14625
ČSN EN 14626
ČSN EN 14662-3
ČSN EN 14902
ČSN EN 15549
ČSN EN 15841
ČSN EN 16450
ČSN EN 27888
ČSN EN ISO 16017-1
ČSN EN ISO 16017-2
ČSN ISO 10304-1
ČSN ISO 10523
ČSN ISO 15923-1
ČSN P CEN/TS 16645