{"lab":{"_id":"69ad52a4de79e566650fd40e","accr_number":"1460","country":"CZ","accr_body":"ČIA","address":"Generála Šišky 942, Libuš, 143 00 Praha 4","categories":["environment"],"city":"Praha 4","imported_at":"2026-03-08T10:42:44.590Z","methods_count":84,"name":"Český hydrometeorologický ústav","parse_status":"parsed","parse_version":5,"pdf_files":["1460_339_2023_CS.pdf","1460_339_2023_EN.pdf"],"scope_summary":"Monitoring imisji (powietrza atmosferycznego) i opadów łącznie z pobieraniem próbek.","search_text":"český hydrometeorologický ústav generála šišky 942, libuš, 143 00 praha 4 1460","status":"active","updated_at":"2026-03-08T14:52:11.964Z","valid_from":"","valid_until":"23-06-2028","website":"www.chmi.cz","location":{"type":"Point","coordinates":[14.4378,50.0755]},"email_confidence":"high","email_mx":true,"email_source":"https://www.chmi.cz","map_coord":[50.009222,14.462504],"map_geo":"nominatim-street","certificate_date":"23.06.2023","certificate_no":"339/2023","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Monitoring imisji (powietrza atmosferycznego) i opadów łącznie z pobieraniem próbek.","en":"Monitoring of immissions (ambient air) and precipitation, including sampling.","zh":"环境空气（环境浓度）和降水监测，包括采样。","cs":"Monitoring imisí (venkovního ovzduší) a srážek včetně vzorkování."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Monitoring Imisji","lab_division_cs":"Imisní monitoring","lab_division_en":"Immission Monitoring","lab_division_zh":"环境空气质量监测","lab_locations":[{"code":null,"name":"Český hydrometeorologický ústav","street":"Generála Šišky 942, Libuš","postal_code":"143 00","city":"Praha 4","is_hq":true,"address":"Generála Šišky 942, Libuš, 143 00 Praha 4","site":"14300|generálašišky942libuš"},{"code":null,"name":"Monitoring imisji, CLI – ČHMÚ Praga","street":"Generála Šišky 942, Libuš","postal_code":"143 00","city":"Praha 4","is_hq":false,"address":"Generála Šišky 942, Libuš, 143 00 Praha 4","site":"14300|generálašišky942libuš"},{"code":null,"name":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","street":"Kočkovská 2699/18","postal_code":"400 11","city":"Ústí nad Labem","is_hq":false,"address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","site":"40011|kočkovská2699/18"},{"code":null,"name":"Monitoring imisji, P – ČHMÚ Ostrawa","street":"K Myslivně 2182/3","postal_code":"708 00","city":"Ostrava","is_hq":false,"address":"K Myslivně 2182/3, 708 00 Ostrava","site":"70800|kmyslivně2182/3"},{"code":null,"name":"Monitoring imisji, P – ČHMÚ Brno","street":"Kroftova 2578/43","postal_code":"616 67","city":"Brno","is_hq":false,"address":"Kroftova 2578/43, 616 67 Brno","site":"61667|kroftova2578/43"},{"code":null,"name":"Monitoring imisji, P – ČHMÚ Hradec Králové","street":"Dvorská 410/102","postal_code":"503 11","city":"Hradec Králové","is_hq":false,"address":"Dvorská 410/102, 503 11 Hradec Králové","site":"50311|dvorská410/102"},{"code":null,"name":"Monitoring imisji, P – ČHMÚ Pilzno","street":"Mozartova 1237/41","postal_code":"323 00","city":"Plzeň","is_hq":false,"address":"Mozartova 1237/41, 323 00 Plzeň","site":"32300|mozartova1237/41"}],"lab_locations_en":[{"code":null,"name":"Český hydrometeorologický ústav","street":"Generála Šišky 942, Libuš","postal_code":"143 00","city":"Praha 4","is_hq":true,"address":"Generála Šišky 942, Libuš, 143 00 Praha 4","site":"14300|generálašišky942libuš"},{"code":null,"name":"Immission monitoring, CLI – ČHMÚ Prague","street":"Generála Šišky 942, Libuš","postal_code":"143 00","city":"Praha 4","is_hq":false,"address":"Generála Šišky 942, Libuš, 143 00 Praha 4","site":"14300|generálašišky942libuš"},{"code":null,"name":"Immission monitoring, P – ČHMÚ Ústí nad Labem","street":"Kočkovská 2699/18","postal_code":"400 11","city":"Ústí nad Labem","is_hq":false,"address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","site":"40011|kočkovská2699/18"},{"code":null,"name":"Immission monitoring, P – ČHMÚ Ostrava","street":"K Myslivně 2182/3","postal_code":"708 00","city":"Ostrava","is_hq":false,"address":"K Myslivně 2182/3, 708 00 Ostrava","site":"70800|kmyslivně2182/3"},{"code":null,"name":"Immission monitoring, P – ČHMÚ Brno","street":"Kroftova 2578/43","postal_code":"616 67","city":"Brno","is_hq":false,"address":"Kroftova 2578/43, 616 67 Brno","site":"61667|kroftova2578/43"},{"code":null,"name":"Immission monitoring, P – ČHMÚ Hradec Králové","street":"Dvorská 410/102","postal_code":"503 11","city":"Hradec Králové","is_hq":false,"address":"Dvorská 410/102, 503 11 Hradec Králové","site":"50311|dvorská410/102"},{"code":null,"name":"Immission monitoring, P – ČHMÚ Plzeň","street":"Mozartova 1237/41","postal_code":"323 00","city":"Plzeň","is_hq":false,"address":"Mozartova 1237/41, 323 00 Plzeň","site":"32300|mozartova1237/41"}],"lab_locations_zh":[{"code":null,"name":"Český hydrometeorologický ústav","street":"Generála Šišky 942, Libuš","postal_code":"143 00","city":"Praha 4","is_hq":true,"address":"Generála Šišky 942, Libuš, 143 00 Praha 4","site":"14300|generálašišky942libuš"},{"code":null,"name":"环境空气质量监测，CLI – ČHMÚ布拉格","street":"Generála Šišky 942, Libuš","postal_code":"143 00","city":"Praha 4","is_hq":false,"address":"Generála Šišky 942, Libuš, 143 00 Praha 4","site":"14300|generálašišky942libuš"},{"code":null,"name":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","street":"Kočkovská 2699/18","postal_code":"400 11","city":"Ústí nad Labem","is_hq":false,"address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","site":"40011|kočkovská2699/18"},{"code":null,"name":"环境空气质量监测，P – ČHMÚ俄斯特拉发","street":"K Myslivně 2182/3","postal_code":"708 00","city":"Ostrava","is_hq":false,"address":"K Myslivně 2182/3, 708 00 Ostrava","site":"70800|kmyslivně2182/3"},{"code":null,"name":"环境空气质量监测，P – ČHMÚ布尔诺","street":"Kroftova 2578/43","postal_code":"616 67","city":"Brno","is_hq":false,"address":"Kroftova 2578/43, 616 67 Brno","site":"61667|kroftova2578/43"},{"code":null,"name":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","street":"Dvorská 410/102","postal_code":"503 11","city":"Hradec Králové","is_hq":false,"address":"Dvorská 410/102, 503 11 Hradec Králové","site":"50311|dvorská410/102"},{"code":null,"name":"环境空气质量监测，P – ČHMÚ比尔森","street":"Mozartova 1237/41","postal_code":"323 00","city":"Plzeň","is_hq":false,"address":"Mozartova 1237/41, 323 00 Plzeň","site":"32300|mozartova1237/41"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"T XX AA-YYY","pl":"wewnętrzna procedura laboratorium","en":"internal procedure of the laboratory","zh":"实验室内部程序","cs":"interní postup laboratoře"},{"abbr":"AAS","pl":"atomowa spektroskopia absorpcyjna","en":"atomic absorption spectroscopy","zh":"原子吸收光谱法","cs":"atomová absorpční spektroskopie"},{"abbr":"CLI","pl":"Centralne Laboratoria Imisji","en":"Central Immission Laboratories","zh":"环境空气中心实验室","cs":"Centrální laboratoře imisí"},{"abbr":"ČHMÚ","pl":"Czeski Instytut Hydrometeorologiczny","en":"Czech Hydrometeorological Institute","zh":"捷克水文气象研究所","cs":"Český hydrometeorologický ústav"},{"abbr":"EMEP","pl":"Co-operative Programme for Monitoring and Evaluation of the Long-range Transmission of Air Pollutants in Europe (Program współpracy w zakresie monitoringu i oceny transgranicznego przenoszenia zanieczyszczeń powietrza w Europie)","en":"Co-operative Programme for Monitoring and Evaluation of the Long-range Transmission of Air Pollutants in Europe","zh":"欧洲空气污染物远距离传输监测与评估合作计划","cs":"Co-operative Programme for Monitoring and Evaluation of the Long-range Transmission of Air Pollutants in Europe (Program spolupráce pro monitoring a vyhodnocení dálkového přenosu znečišťujících látek v Evropě)"},{"abbr":"EPA","pl":"Environmental Protection Agency (Agencja Ochrony Środowiska)","en":"Environmental Protection Agency","zh":"美国环境保护署","cs":"Environmental Protection Agency (Agentura pro ochranu životního prostředí)"},{"abbr":"GC-FID","pl":"chromatografia gazowa z detekcją płomieniowo-jonizacyjną","en":"Gas Chromatography/Flame-ionization detector","zh":"气相色谱-火焰离子化检测","cs":"Gas Chromatography/Flame-ionization detector (plynová chromatografie s plamenoionizační detekcí)"},{"abbr":"GC-PID","pl":"chromatografia gazowa z detekcją fotojonizacyjną","en":"Gas Chromatography/Photo-ionization detector","zh":"气相色谱-光离子化检测","cs":"Gas Chromatography/Photo-ionization detector (plynová chromatografie s fotoionizační detekcí)"},{"abbr":"GC-MS","pl":"chromatografia gazowa ze spektrometrią mas","en":"Gas Chromatography/Mass Spectrometry","zh":"气相色谱-质谱法","cs":"Gas Chromatography/Mass Spectrometry (plynová chromatografie s hmotnostní detekcí)"},{"abbr":"ICP-MS","pl":"spektrometria mas z plazmą wzbudzoną indukcyjnie","en":"Inductively Coupled Plasma Mass Spectrometry","zh":"电感耦合等离子体质谱法","cs":"Inductive Coupled Plasma, Mass Spectrometry (hmotnostní spektrometrie s indukčně vázanou plazmou)"},{"abbr":"P","pl":"oddział","en":"branch","zh":"分支机构","cs":"pobočka"},{"abbr":"PMX","pl":"frakcja cząstek aerozolu przechodząca przez wlot urządzenia do poboru próbek rozdzielający cząstki według wielkości, o skuteczności granicznej 50 % dla cząstek o średnicy aerodynamicznej X μm","en":"fraction of aerosol particles passing through a size-selective inlet of the sampling device with a 50 % cut-off efficiency for particles of aerodynamic diameter X μm","zh":"通过采样装置粒径选择性入口的气溶胶颗粒组分，对空气动力学直径X μm颗粒的截留效率为50 %","cs":"frakce aerosolových částic, která prochází vstupním otvorem rozlišujícím podle velikosti částic vzorkovacího zařízení s mezní účinností 50 % pro částice aerodynamického průměru X μm"},{"abbr":"PUF","pl":"Filtr poliuretanowy","en":"Polyurethane foam filter","zh":"聚氨酯泡沫滤器","cs":"Polyuretanový filtr"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"d32bbd818b88b8a6230e9630778b61686d3b2e7451b5e80272e2f13e45990686","source_pdf_url":"https://www.cai.cz/OA/pdf/P339_2023_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"6f6d9701e613a90040d97228","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"1","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda potencjometryczna","technique_en":"potentiometric method","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["metoda potencjometryczna"],"techniques_en":["potentiometric method"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną\nmetoda potencjometryczna","reference":"T 21 AA-001 (ČSN ISO 10523)","norm_bases":["T 21 AA-001","ČSN ISO 10523"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Oznaczanie pH metodą potencjometryczną metoda potencjometryczna Srážková voda Stanovení pH potenciometricky potenciometricky T 21 AA-001 (ČSN ISO 10523) Woda opadowa Oznaczanie pH metoda potencjometryczna metoda potencjometryczna Srazkova voda Stanoveni pH potenciometricky potenciometricky T 21 AA-001 (CSN ISO 10523)","search_en":"Precipitation water Determination of pH by potentiometry potentiometric method T 21 AA-001 (ČSN ISO 10523)","search_zh":"降水 电位法测定pH 电位法 T 21 AA-001 (ČSN ISO 10523)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"59403d4de504be851f668496","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"2","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Oznaczanie przewodności elektrycznej właściwej metodą konduktometrii bezpośredniej","methodology_en":"Determination of electrical conductivity by direct conductometry","methodology_zh":"直接电导法测定电导率","methodology_cs":"Stanovení elektrické konduktivity přímou konduktometrií","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"konduktometria bezpośrednia","technique_en":"direct conductometry","technique_zh":"直接电导法","technique_cs":"přímou konduktometrií","techniques":["konduktometria bezpośrednia"],"techniques_en":["direct conductometry"],"techniques_zh":["直接电导法"],"techniques_cs":["přímou konduktometrií"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej metodą konduktometrii bezpośredniej\nkonduktometria bezpośrednia","reference":"T 21 AA-002 (ČSN EN 27888)","norm_bases":["T 21 AA-002","ČSN EN 27888"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Oznaczanie przewodności elektrycznej właściwej metodą konduktometrii bezpośredniej konduktometria bezpośrednia Srážková voda Stanovení elektrické konduktivity přímou konduktometrií přímou konduktometrií T 21 AA-002 (ČSN EN 27888) Woda opadowa Oznaczanie przewodnosci elektrycznej wlasciwej metoda konduktometrii bezposredniej konduktometria bezposrednia Srazkova voda Stanoveni elektricke konduktivity primou konduktometrii primou konduktometrii T 21 AA-002 (CSN EN 27888)","search_en":"Precipitation water Determination of electrical conductivity by direct conductometry direct conductometry T 21 AA-002 (ČSN EN 27888)","search_zh":"降水 直接电导法测定电导率 直接电导法 T 21 AA-002 (ČSN EN 27888)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7771c7f05eaec1e2ec668357","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"3","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie lotnych związków organicznych (VOC) metodą GC-FID","methodology_en":"Determination of volatile organic compounds (VOC) by GC-FID","methodology_zh":"GC-FID法测定挥发性有机物（VOC）","methodology_cs":"Stanovení těkavých organických látek (VOC) metodou GC-FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"chromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID)","technique_en":"gas chromatography with flame ionisation detector (GC-FID)","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","technique_cs":"metodou GC-FID","techniques":["chromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID)"],"techniques_en":["gas chromatography with flame ionisation detector (GC-FID)"],"techniques_zh":["气相色谱-火焰离子化检测法（GC-FID）"],"techniques_cs":["metodou GC-FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lotnych związków organicznych (VOC) metodą GC-FID\nchromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID)","reference":"T 21 AA-003 (EPA Methods: Method TO14)","norm_bases":["T 21 AA-003","EPA Methods: Method TO14"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"etan, eten, propan, propen, izobutan, n-butan, suma butenów, izopentan, n-pentan, suma pentenów, n-heksan, izopren, n-heptan, benzen, toluen, izooktan, n-oktan, etylobenzen, m,p-ksylen, o-ksylen. Literatura źródłowa: TO14 Determination of volatile organic compounds (VOCs) in ambient air using SUMMA® passivated canister sampling and gas chromatographic analysis","note_en":"ethane, ethene, propane, propene, i-butane, n-butane, sum of butenes, i-pentane, n-pentane, sum of pentenes, n-hexane, isoprene, n-heptane, benzene, toluene, i-octane, n-octane, ethylbenzene, m,p-xylene, o-xylene. Source literature: TO14 Determination of volatile organic compounds (VOCs) in ambient air using SUMMA® passivated canister sampling and gas chromatographic analysis","note_zh":"乙烷、乙烯、丙烷、丙烯、异丁烷、正丁烷、丁烯总量、异戊烷、正戊烷、戊烯总量、正己烷、异戊二烯、正庚烷、苯、甲苯、异辛烷、正辛烷、乙苯、间/对二甲苯、邻二甲苯。来源文献：TO14 Determination of volatile organic compounds (VOCs) in ambient air using SUMMA® passivated canister sampling and gas chromatographic analysis","note_cs":"etan, eten, propan, propen, i-butan, n-butan, suma buteny, i-pentan, n-pentan, suma penteny, n-hexan, isopren, n-heptan, benzen, toluen, i-oktan, n-oktan, etylbenzen, m,p-xylen, o-xylen. Zdrojová literatura: TO14 Determination of volatile organic compounds (VOCs) in ambient air using SUMMA® passivated canister sampling and gas chromatographic analysis","search_text":"Powietrze atmosferyczne (imisja) Oznaczanie lotnych związków organicznych (VOC) metodą GC-FID chromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID) Venkovní ovzduší (imise) Stanovení těkavých organických látek (VOC) metodou GC-FID metodou GC-FID T 21 AA-003 (EPA Methods: Method TO14) Powietrze atmosferyczne (imisja) Oznaczanie lotnych zwiazkow organicznych (VOC) metoda GC-FID chromatografia gazowa z detektorem plomieniowo-jonizacyjnym (GC-FID) Venkovni ovzdusi (imise) Stanoveni tekavych organickych latek (VOC) metodou GC-FID metodou GC-FID T 21 AA-003 (EPA Methods: Method TO14)","search_en":"Ambient air (immissions) Determination of volatile organic compounds (VOC) by GC-FID gas chromatography with flame ionisation detector (GC-FID) T 21 AA-003 (EPA Methods: Method TO14)","search_zh":"环境空气（环境浓度） GC-FID法测定挥发性有机物（VOC） 气相色谱-火焰离子化检测法（GC-FID） T 21 AA-003 (EPA Methods: Method TO14)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4be1d0c8270b92db57b277b9","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"4","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie Ni, As, Cd i Pb metodą ICP-MS","methodology_en":"Determination of Ni, As, Cd and Pb by ICP-MS","methodology_zh":"ICP-MS法测定Ni、As、Cd和Pb","methodology_cs":"Stanovení Ni, As, Cd a Pb metodou ICP-MS","parameters":[{"name":"Nikiel (Ni)","range":""},{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Ołów (Pb)","range":""}],"parameters_en":[{"name":"Nickel (Ni)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Lead (Pb)","range":""}],"parameters_zh":[{"name":"镍（Ni）","range":""},{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""},{"name":"铅（Pb）","range":""}],"parameters_cs":[{"name":"Ni","range":""},{"name":"As","range":""},{"name":"Cd","range":""},{"name":"Pb","range":""}],"technique":"spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","technique_en":"inductively coupled plasma mass spectrometry (ICP-MS)","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","technique_cs":"metodou ICP-MS","techniques":["spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)"],"techniques_en":["inductively coupled plasma mass spectrometry (ICP-MS)"],"techniques_zh":["电感耦合等离子体质谱法（ICP-MS）"],"techniques_cs":["metodou ICP-MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Ni, As, Cd i Pb metodą ICP-MS\nZakres:\nNikiel (Ni)\nArsen (As)\nKadm (Cd)\nOłów (Pb)\nspektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","reference":"T 21 AA-005 (EMEP manual for sampling and chemical analysis; ČSN EN 14902)","norm_bases":["T 21 AA-005","EMEP manual for sampling and chemical analysis","ČSN EN 14902"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie Ni, As, Cd i Pb metodą ICP-MS spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS) Nikiel (Ni)  Arsen (As)  Kadm (Cd)  Ołów (Pb)  Venkovní ovzduší (imise) Stanovení Ni, As, Cd a Pb metodou ICP-MS metodou ICP-MS Ni  As  Cd  Pb  T 21 AA-005 (EMEP manual for sampling and chemical analysis; ČSN EN 14902) Powietrze atmosferyczne (imisja) Oznaczanie Ni, As, Cd i Pb metoda ICP-MS spektrometria mas z plazma wzbudzona indukcyjnie (ICP-MS) Nikiel (Ni)  Arsen (As)  Kadm (Cd)  Olow (Pb)  Venkovni ovzdusi (imise) Stanoveni Ni, As, Cd a Pb metodou ICP-MS metodou ICP-MS Ni  As  Cd  Pb  T 21 AA-005 (EMEP manual for sampling and chemical analysis; CSN EN 14902)","search_en":"Ambient air (immissions) Determination of Ni, As, Cd and Pb by ICP-MS inductively coupled plasma mass spectrometry (ICP-MS) Nickel (Ni)  Arsenic (As)  Cadmium (Cd)  Lead (Pb)  T 21 AA-005 (EMEP manual for sampling and chemical analysis; ČSN EN 14902)","search_zh":"环境空气（环境浓度） ICP-MS法测定Ni、As、Cd和Pb 电感耦合等离子体质谱法（ICP-MS） 镍（Ni）  砷（As）  镉（Cd）  铅（Pb）  T 21 AA-005 (EMEP manual for sampling and chemical analysis; ČSN EN 14902)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25aff992312d92b9b3872dcd","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"5","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Oznaczanie F-, Cl-, NO3- i SO42- metodą chromatografii jonowej","methodology_en":"Determination of F-, Cl-, NO3- and SO42- by ion chromatography","methodology_zh":"离子色谱法测定F-、Cl-、NO3-和SO42-","methodology_cs":"Stanovení F-, Cl-, NO3- a SO42- iontovou chromatografií","parameters":[{"name":"fluorki (F-)","range":""},{"name":"chlorki (Cl-)","range":""},{"name":"azotany (NO3-)","range":""},{"name":"siarczany (SO42-)","range":""}],"parameters_en":[{"name":"fluoride (F-)","range":""},{"name":"chloride (Cl-)","range":""},{"name":"nitrate (NO3-)","range":""},{"name":"sulphate (SO42-)","range":""}],"parameters_zh":[{"name":"氟离子（F-）","range":""},{"name":"氯离子（Cl-）","range":""},{"name":"硝酸根（NO3-）","range":""},{"name":"硫酸根（SO42-）","range":""}],"parameters_cs":[{"name":"F-","range":""},{"name":"Cl-","range":""},{"name":"NO3-","range":""},{"name":"SO42-","range":""}],"technique":"chromatografia jonowa","technique_en":"ion chromatography","technique_zh":"离子色谱法","technique_cs":"iontovou chromatografií","techniques":["chromatografia jonowa"],"techniques_en":["ion chromatography"],"techniques_zh":["离子色谱法"],"techniques_cs":["iontovou chromatografií"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie F-, Cl-, NO3- i SO42- metodą chromatografii jonowej\nZakres:\nfluorki (F-)\nchlorki (Cl-)\nazotany (NO3-)\nsiarczany (SO42-)\nchromatografia jonowa","reference":"T 21 AA-008 (ČSN ISO 10304-1)","norm_bases":["T 21 AA-008","ČSN ISO 10304-1"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Oznaczanie F-, Cl-, NO3- i SO42- metodą chromatografii jonowej chromatografia jonowa fluorki (F-)  chlorki (Cl-)  azotany (NO3-)  siarczany (SO42-)  Srážková voda Stanovení F-, Cl-, NO3- a SO42- iontovou chromatografií iontovou chromatografií F-  Cl-  NO3-  SO42-  T 21 AA-008 (ČSN ISO 10304-1) Woda opadowa Oznaczanie F-, Cl-, NO3- i SO42- metoda chromatografii jonowej chromatografia jonowa fluorki (F-)  chlorki (Cl-)  azotany (NO3-)  siarczany (SO42-)  Srazkova voda Stanoveni F-, Cl-, NO3- a SO42- iontovou chromatografii iontovou chromatografii F-  Cl-  NO3-  SO42-  T 21 AA-008 (CSN ISO 10304-1)","search_en":"Precipitation water Determination of F-, Cl-, NO3- and SO42- by ion chromatography ion chromatography fluoride (F-)  chloride (Cl-)  nitrate (NO3-)  sulphate (SO42-)  T 21 AA-008 (ČSN ISO 10304-1)","search_zh":"降水 离子色谱法测定F-、Cl-、NO3-和SO42- 离子色谱法 氟离子（F-）  氯离子（Cl-）  硝酸根（NO3-）  硫酸根（SO42-）  T 21 AA-008 (ČSN ISO 10304-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"12d957fb98a2fecf96894878","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"6","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą GC-MS","methodology_en":"Determination of polycyclic aromatic hydrocarbons by GC-MS","methodology_zh":"GC-MS法测定多环芳烃","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků metodou GC-MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"chromatografia gazowa ze spektrometrią mas (GC-MS)","technique_en":"gas chromatography – mass spectrometry (GC-MS)","technique_zh":"气相色谱-质谱法（GC-MS）","technique_cs":"metodou GC-MS","techniques":["chromatografia gazowa ze spektrometrią mas (GC-MS)"],"techniques_en":["gas chromatography – mass spectrometry (GC-MS)"],"techniques_zh":["气相色谱-质谱法（GC-MS）"],"techniques_cs":["metodou GC-MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą GC-MS\nchromatografia gazowa ze spektrometrią mas (GC-MS)","reference":"T 21 AA-009 (ČSN EN 15549; ČSN P CEN/TS 16645; ISO 12884)","norm_bases":["T 21 AA-009","ČSN EN 15549","ČSN P CEN/TS 16645","ISO 12884"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"fluoren, fenantren, antracen, fluoranten, piren, benzo[a]antracen, chryzen, benzo[b]fluoranten, benzo[k]fluoranten, benzo[a]piren, indeno[1,2,3-c,d]piren, dibenzo[a,h]antracen, benzo[g,h,i]perylen","note_en":"fluorene, phenanthrene, anthracene, fluoranthene, pyrene, benzo[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, indeno[1,2,3-c,d]pyrene, dibenz[a,h]anthracene, benzo[g,h,i]perylene","note_zh":"芴、菲、蒽、荧蒽、芘、苯并[a]蒽、䓛、苯并[b]荧蒽、苯并[k]荧蒽、苯并[a]芘、茚并[1,2,3-c,d]芘、二苯并[a,h]蒽、苯并[g,h,i]苝","note_cs":"fluoren, fenantren, antracen, fluoranten, pyren, benzo[a]antracen, chrysen, benzo[b]fluoranten, benzo[k] fluoranten, benzo[a] pyren, indeno[1,2,3,c,d]pyren, dibenz[a,h]antracen, benzo[g,h,i]perylen","search_text":"Powietrze atmosferyczne (imisja) Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą GC-MS chromatografia gazowa ze spektrometrią mas (GC-MS) Venkovní ovzduší (imise) Stanovení polycyklických aromatických uhlovodíků metodou GC-MS metodou GC-MS T 21 AA-009 (ČSN EN 15549; ČSN P CEN/TS 16645; ISO 12884) Powietrze atmosferyczne (imisja) Oznaczanie wielopierscieniowych weglowodorow aromatycznych metoda GC-MS chromatografia gazowa ze spektrometria mas (GC-MS) Venkovni ovzdusi (imise) Stanoveni polycyklickych aromatickych uhlovodiku metodou GC-MS metodou GC-MS T 21 AA-009 (CSN EN 15549; CSN P CEN/TS 16645; ISO 12884)","search_en":"Ambient air (immissions) Determination of polycyclic aromatic hydrocarbons by GC-MS gas chromatography – mass spectrometry (GC-MS) T 21 AA-009 (ČSN EN 15549; ČSN P CEN/TS 16645; ISO 12884)","search_zh":"环境空气（环境浓度） GC-MS法测定多环芳烃 气相色谱-质谱法（GC-MS） T 21 AA-009 (ČSN EN 15549; ČSN P CEN/TS 16645; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73dfbda1aa6f52eae49a31d1","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"7","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie gazowego amoniaku i jonów amonowych metodą spektrofotometryczną, wyrażonych jako suma jonów amonowych","methodology_en":"Determination of gaseous ammonia and ammonium ions by spectrophotometric method, expressed as the sum of ammonium ions","methodology_zh":"分光光度法测定气态氨和铵离子（以铵离子总量表示）","methodology_cs":"Stanovení plynného amoniaku a amonných iontů spektrofotometrickou metodou vyjádřených jako suma amonných iontů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometrickou metodou","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometrickou metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gazowego amoniaku i jonów amonowych metodą spektrofotometryczną, wyrażonych jako suma jonów amonowych\nmetoda spektrofotometryczna","reference":"T 21 AA-014 (ČSN ISO 15923-1)","norm_bases":["T 21 AA-014","ČSN ISO 15923-1"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie gazowego amoniaku i jonów amonowych metodą spektrofotometryczną, wyrażonych jako suma jonów amonowych metoda spektrofotometryczna Venkovní ovzduší (imise) Stanovení plynného amoniaku a amonných iontů spektrofotometrickou metodou vyjádřených jako suma amonných iontů spektrofotometrickou metodou T 21 AA-014 (ČSN ISO 15923-1) Powietrze atmosferyczne (imisja) Oznaczanie gazowego amoniaku i jonow amonowych metoda spektrofotometryczna, wyrazonych jako suma jonow amonowych metoda spektrofotometryczna Venkovni ovzdusi (imise) Stanoveni plynneho amoniaku a amonnych iontu spektrofotometrickou metodou vyjadrenych jako suma amonnych iontu spektrofotometrickou metodou T 21 AA-014 (CSN ISO 15923-1)","search_en":"Ambient air (immissions) Determination of gaseous ammonia and ammonium ions by spectrophotometric method, expressed as the sum of ammonium ions spectrophotometric method T 21 AA-014 (ČSN ISO 15923-1)","search_zh":"环境空气（环境浓度） 分光光度法测定气态氨和铵离子（以铵离子总量表示） 分光光度法 T 21 AA-014 (ČSN ISO 15923-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7bfe05d7917983a355f68a05","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"8","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)","methodology_en":"Gravimetric determination of aerosol particles (PM10 and PM2.5)","methodology_zh":"重量法测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Gravimetrické stanovení aerosolových částic (PM10 a PM2,5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetric method","technique_zh":"重量法","technique_cs":"gravimetrické","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrické"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)\nmetoda grawimetryczna","reference":"T 21 AA-015 (ČSN EN 12341)","norm_bases":["T 21 AA-015","ČSN EN 12341"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovní ovzduší (imise) Gravimetrické stanovení aerosolových částic (PM10 a PM2,5) gravimetrické T 21 AA-015 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie czastek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovni ovzdusi (imise) Gravimetricke stanoveni aerosolovych castic (PM10 a PM2,5) gravimetricke T 21 AA-015 (CSN EN 12341)","search_en":"Ambient air (immissions) Gravimetric determination of aerosol particles (PM10 and PM2.5) gravimetric method T 21 AA-015 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 重量法测定气溶胶颗粒（PM10和PM2.5） 重量法 T 21 AA-015 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e49867270b002588391aff4","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"8","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)","methodology_en":"Gravimetric determination of aerosol particles (PM10 and PM2.5)","methodology_zh":"重量法测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Gravimetrické stanovení aerosolových částic (PM10 a PM2,5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetric method","technique_zh":"重量法","technique_cs":"gravimetrické","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrické"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)\nmetoda grawimetryczna","reference":"T 21 AA-015 (ČSN EN 12341)","norm_bases":["T 21 AA-015","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovní ovzduší (imise) Gravimetrické stanovení aerosolových částic (PM10 a PM2,5) gravimetrické T 21 AA-015 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie czastek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovni ovzdusi (imise) Gravimetricke stanoveni aerosolovych castic (PM10 a PM2,5) gravimetricke T 21 AA-015 (CSN EN 12341)","search_en":"Ambient air (immissions) Gravimetric determination of aerosol particles (PM10 and PM2.5) gravimetric method T 21 AA-015 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 重量法测定气溶胶颗粒（PM10和PM2.5） 重量法 T 21 AA-015 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bb45532459e5b15f8fc8ce1d","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"8","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)","methodology_en":"Gravimetric determination of aerosol particles (PM10 and PM2.5)","methodology_zh":"重量法测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Gravimetrické stanovení aerosolových částic (PM10 a PM2,5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetric method","technique_zh":"重量法","technique_cs":"gravimetrické","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrické"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)\nmetoda grawimetryczna","reference":"T 21 AA-015 (ČSN EN 12341)","norm_bases":["T 21 AA-015","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovní ovzduší (imise) Gravimetrické stanovení aerosolových částic (PM10 a PM2,5) gravimetrické T 21 AA-015 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie czastek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovni ovzdusi (imise) Gravimetricke stanoveni aerosolovych castic (PM10 a PM2,5) gravimetricke T 21 AA-015 (CSN EN 12341)","search_en":"Ambient air (immissions) Gravimetric determination of aerosol particles (PM10 and PM2.5) gravimetric method T 21 AA-015 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 重量法测定气溶胶颗粒（PM10和PM2.5） 重量法 T 21 AA-015 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6a2d65434fc6aae9adba61e6","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"8","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)","methodology_en":"Gravimetric determination of aerosol particles (PM10 and PM2.5)","methodology_zh":"重量法测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Gravimetrické stanovení aerosolových částic (PM10 a PM2,5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda grawimetryczna","technique_en":"gravimetric method","technique_zh":"重量法","technique_cs":"gravimetrické","techniques":["metoda grawimetryczna"],"techniques_en":["gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetrické"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5)\nmetoda grawimetryczna","reference":"T 21 AA-015 (ČSN EN 12341)","norm_bases":["T 21 AA-015","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie cząstek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovní ovzduší (imise) Gravimetrické stanovení aerosolových částic (PM10 a PM2,5) gravimetrické T 21 AA-015 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Grawimetryczne oznaczanie czastek aerozolu (PM10 i PM2,5) metoda grawimetryczna Venkovni ovzdusi (imise) Gravimetricke stanoveni aerosolovych castic (PM10 a PM2,5) gravimetricke T 21 AA-015 (CSN EN 12341)","search_en":"Ambient air (immissions) Gravimetric determination of aerosol particles (PM10 and PM2.5) gravimetric method T 21 AA-015 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 重量法测定气溶胶颗粒（PM10和PM2.5） 重量法 T 21 AA-015 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"570f1b1557e7fc53647941fc","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"9","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Oznaczanie Ca, Mg, Na, K metodą AAS","methodology_en":"Determination of Ca, Mg, Na, K by AAS","methodology_zh":"AAS法测定Ca、Mg、Na、K","methodology_cs":"Stanovení Ca, Mg, Na, K metodou AAS","parameters":[{"name":"Wapń (Ca)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Sód (Na)","range":""},{"name":"Potas (K)","range":""}],"parameters_en":[{"name":"Calcium (Ca)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Potassium (K)","range":""}],"parameters_zh":[{"name":"钙（Ca）","range":""},{"name":"镁（Mg）","range":""},{"name":"钠（Na）","range":""},{"name":"钾（K）","range":""}],"parameters_cs":[{"name":"Ca","range":""},{"name":"Mg","range":""},{"name":"Na","range":""},{"name":"K","range":""}],"technique":"atomowa spektroskopia absorpcyjna (AAS)","technique_en":"atomic absorption spectroscopy (AAS)","technique_zh":"原子吸收光谱法（AAS）","technique_cs":"metodou AAS","techniques":["atomowa spektroskopia absorpcyjna (AAS)"],"techniques_en":["atomic absorption spectroscopy (AAS)"],"techniques_zh":["原子吸收光谱法（AAS）"],"techniques_cs":["metodou AAS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Ca, Mg, Na, K metodą AAS\nZakres:\nWapń (Ca)\nMagnez (Mg)\nSód (Na)\nPotas (K)\natomowa spektroskopia absorpcyjna (AAS)","reference":"T 21 AA-016 (EMEP manual for sampling and chemical analysis)","norm_bases":["T 21 AA-016","EMEP manual for sampling and chemical analysis"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Oznaczanie Ca, Mg, Na, K metodą AAS atomowa spektroskopia absorpcyjna (AAS) Wapń (Ca)  Magnez (Mg)  Sód (Na)  Potas (K)  Srážková voda Stanovení Ca, Mg, Na, K metodou AAS metodou AAS Ca  Mg  Na  K  T 21 AA-016 (EMEP manual for sampling and chemical analysis) Woda opadowa Oznaczanie Ca, Mg, Na, K metoda AAS atomowa spektroskopia absorpcyjna (AAS) Wapn (Ca)  Magnez (Mg)  Sod (Na)  Potas (K)  Srazkova voda Stanoveni Ca, Mg, Na, K metodou AAS metodou AAS Ca  Mg  Na  K  T 21 AA-016 (EMEP manual for sampling and chemical analysis)","search_en":"Precipitation water Determination of Ca, Mg, Na, K by AAS atomic absorption spectroscopy (AAS) Calcium (Ca)  Magnesium (Mg)  Sodium (Na)  Potassium (K)  T 21 AA-016 (EMEP manual for sampling and chemical analysis)","search_zh":"降水 AAS法测定Ca、Mg、Na、K 原子吸收光谱法（AAS） 钙（Ca）  镁（Mg）  钠（Na）  钾（K）  T 21 AA-016 (EMEP manual for sampling and chemical analysis)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd65812c1f50aea811a7f6a8","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"10","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Oznaczanie Ni, As, Cd i Pb metodą ICP-MS","methodology_en":"Determination of Ni, As, Cd and Pb by ICP-MS","methodology_zh":"ICP-MS法测定Ni、As、Cd和Pb","methodology_cs":"Stanovení Ni, As, Cd a Pb metodou ICP-MS","parameters":[{"name":"Nikiel (Ni)","range":""},{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Ołów (Pb)","range":""}],"parameters_en":[{"name":"Nickel (Ni)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Lead (Pb)","range":""}],"parameters_zh":[{"name":"镍（Ni）","range":""},{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""},{"name":"铅（Pb）","range":""}],"parameters_cs":[{"name":"Ni","range":""},{"name":"As","range":""},{"name":"Cd","range":""},{"name":"Pb","range":""}],"technique":"spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","technique_en":"inductively coupled plasma mass spectrometry (ICP-MS)","technique_zh":"电感耦合等离子体质谱法（ICP-MS）","technique_cs":"metodou ICP-MS","techniques":["spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)"],"techniques_en":["inductively coupled plasma mass spectrometry (ICP-MS)"],"techniques_zh":["电感耦合等离子体质谱法（ICP-MS）"],"techniques_cs":["metodou ICP-MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Ni, As, Cd i Pb metodą ICP-MS\nZakres:\nNikiel (Ni)\nArsen (As)\nKadm (Cd)\nOłów (Pb)\nspektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS)","reference":"T 21 AA-017 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","norm_bases":["T 21 AA-017","EMEP manual for sampling and chemical analysis","ČSN EN 15841"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Oznaczanie Ni, As, Cd i Pb metodą ICP-MS spektrometria mas z plazmą wzbudzoną indukcyjnie (ICP-MS) Nikiel (Ni)  Arsen (As)  Kadm (Cd)  Ołów (Pb)  Srážková voda Stanovení Ni, As, Cd a Pb metodou ICP-MS metodou ICP-MS Ni  As  Cd  Pb  T 21 AA-017 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) Woda opadowa Oznaczanie Ni, As, Cd i Pb metoda ICP-MS spektrometria mas z plazma wzbudzona indukcyjnie (ICP-MS) Nikiel (Ni)  Arsen (As)  Kadm (Cd)  Olow (Pb)  Srazkova voda Stanoveni Ni, As, Cd a Pb metodou ICP-MS metodou ICP-MS Ni  As  Cd  Pb  T 21 AA-017 (EMEP manual for sampling and chemical analysis; CSN EN 15841)","search_en":"Precipitation water Determination of Ni, As, Cd and Pb by ICP-MS inductively coupled plasma mass spectrometry (ICP-MS) Nickel (Ni)  Arsenic (As)  Cadmium (Cd)  Lead (Pb)  T 21 AA-017 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","search_zh":"降水 ICP-MS法测定Ni、As、Cd和Pb 电感耦合等离子体质谱法（ICP-MS） 镍（Ni）  砷（As）  镉（Cd）  铅（Pb）  T 21 AA-017 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e69516514b02a7f092214478","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"11","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie benzenu metodą GC-FID","methodology_en":"Determination of benzene by GC-FID","methodology_zh":"GC-FID法测定苯","methodology_cs":"Stanovení benzenu metodou GC-FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"chromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID)","technique_en":"gas chromatography with flame ionisation detector (GC-FID)","technique_zh":"气相色谱-火焰离子化检测法（GC-FID）","technique_cs":"metodou GC-FID","techniques":["chromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID)"],"techniques_en":["gas chromatography with flame ionisation detector (GC-FID)"],"techniques_zh":["气相色谱-火焰离子化检测法（GC-FID）"],"techniques_cs":["metodou GC-FID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie benzenu metodą GC-FID\nchromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID)","reference":"T 21 AA-019 (ČSN EN ISO 16017-1; ČSN EN ISO 16017-2)","norm_bases":["T 21 AA-019","ČSN EN ISO 16017-1","ČSN EN ISO 16017-2"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie benzenu metodą GC-FID chromatografia gazowa z detektorem płomieniowo-jonizacyjnym (GC-FID) Venkovní ovzduší (imise) Stanovení benzenu metodou GC-FID metodou GC-FID T 21 AA-019 (ČSN EN ISO 16017-1; ČSN EN ISO 16017-2) Powietrze atmosferyczne (imisja) Oznaczanie benzenu metoda GC-FID chromatografia gazowa z detektorem plomieniowo-jonizacyjnym (GC-FID) Venkovni ovzdusi (imise) Stanoveni benzenu metodou GC-FID metodou GC-FID T 21 AA-019 (CSN EN ISO 16017-1; CSN EN ISO 16017-2)","search_en":"Ambient air (immissions) Determination of benzene by GC-FID gas chromatography with flame ionisation detector (GC-FID) T 21 AA-019 (ČSN EN ISO 16017-1; ČSN EN ISO 16017-2)","search_zh":"环境空气（环境浓度） GC-FID法测定苯 气相色谱-火焰离子化检测法（GC-FID） T 21 AA-019 (ČSN EN ISO 16017-1; ČSN EN ISO 16017-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"45a4ded67ced432bf6fce271","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"12","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Oznaczanie jonów amonowych metodą spektrofotometryczną","methodology_en":"Determination of ammonium ions by spectrophotometric method","methodology_zh":"分光光度法测定铵离子","methodology_cs":"Stanovení amonných iontů spektrofotometrickou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda spektrofotometryczna","technique_en":"spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometrickou metodou","techniques":["metoda spektrofotometryczna"],"techniques_en":["spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometrickou metodou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą spektrofotometryczną\nmetoda spektrofotometryczna","reference":"T 21 AA-020 (ČSN ISO 15923-1)","norm_bases":["T 21 AA-020","ČSN ISO 15923-1"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Oznaczanie jonów amonowych metodą spektrofotometryczną metoda spektrofotometryczna Srážková voda Stanovení amonných iontů spektrofotometrickou metodou spektrofotometrickou metodou T 21 AA-020 (ČSN ISO 15923-1) Woda opadowa Oznaczanie jonow amonowych metoda spektrofotometryczna metoda spektrofotometryczna Srazkova voda Stanoveni amonnych iontu spektrofotometrickou metodou spektrofotometrickou metodou T 21 AA-020 (CSN ISO 15923-1)","search_en":"Precipitation water Determination of ammonium ions by spectrophotometric method spectrophotometric method T 21 AA-020 (ČSN ISO 15923-1)","search_zh":"降水 分光光度法测定铵离子 分光光度法 T 21 AA-020 (ČSN ISO 15923-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc98e53ed6a5bec5d7aed0c3","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"13","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi","methodology_en":"Determination of SO2 by automatic fluorescence analysers","methodology_zh":"自动荧光分析仪测定SO2","methodology_cs":"Stanovení SO2 automatickými fluorescenčními analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fluorescencyjne","technique_en":"automatic fluorescence analysers","technique_zh":"自动荧光分析仪","technique_cs":"automatickými fluorescenčními analyzátory","techniques":["automatyczne analizatory fluorescencyjne"],"techniques_en":["automatic fluorescence analysers"],"techniques_zh":["自动荧光分析仪"],"techniques_cs":["automatickými fluorescenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi\nautomatyczne analizatory fluorescencyjne","reference":"T 22 AA-001 (ČSN EN 14212)","norm_bases":["T 22 AA-001","ČSN EN 14212"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovní ovzduší (imise) Stanovení SO2 automatickými fluorescenčními analyzátory automatickými fluorescenčními analyzátory T 22 AA-001 (ČSN EN 14212) Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovni ovzdusi (imise) Stanoveni SO2 automatickymi fluorescencnimi analyzatory automatickymi fluorescencnimi analyzatory T 22 AA-001 (CSN EN 14212)","search_en":"Ambient air (immissions) Determination of SO2 by automatic fluorescence analysers automatic fluorescence analysers T 22 AA-001 (ČSN EN 14212)","search_zh":"环境空气（环境浓度） 自动荧光分析仪测定SO2 自动荧光分析仪 T 22 AA-001 (ČSN EN 14212)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"234e3070bf020b0ea34b8cac","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"13","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi","methodology_en":"Determination of SO2 by automatic fluorescence analysers","methodology_zh":"自动荧光分析仪测定SO2","methodology_cs":"Stanovení SO2 automatickými fluorescenčními analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fluorescencyjne","technique_en":"automatic fluorescence analysers","technique_zh":"自动荧光分析仪","technique_cs":"automatickými fluorescenčními analyzátory","techniques":["automatyczne analizatory fluorescencyjne"],"techniques_en":["automatic fluorescence analysers"],"techniques_zh":["自动荧光分析仪"],"techniques_cs":["automatickými fluorescenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi\nautomatyczne analizatory fluorescencyjne","reference":"T 22 AA-001 (ČSN EN 14212)","norm_bases":["T 22 AA-001","ČSN EN 14212"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovní ovzduší (imise) Stanovení SO2 automatickými fluorescenčními analyzátory automatickými fluorescenčními analyzátory T 22 AA-001 (ČSN EN 14212) Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovni ovzdusi (imise) Stanoveni SO2 automatickymi fluorescencnimi analyzatory automatickymi fluorescencnimi analyzatory T 22 AA-001 (CSN EN 14212)","search_en":"Ambient air (immissions) Determination of SO2 by automatic fluorescence analysers automatic fluorescence analysers T 22 AA-001 (ČSN EN 14212)","search_zh":"环境空气（环境浓度） 自动荧光分析仪测定SO2 自动荧光分析仪 T 22 AA-001 (ČSN EN 14212)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79084fd6626f1f889c2aa440","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"13","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi","methodology_en":"Determination of SO2 by automatic fluorescence analysers","methodology_zh":"自动荧光分析仪测定SO2","methodology_cs":"Stanovení SO2 automatickými fluorescenčními analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fluorescencyjne","technique_en":"automatic fluorescence analysers","technique_zh":"自动荧光分析仪","technique_cs":"automatickými fluorescenčními analyzátory","techniques":["automatyczne analizatory fluorescencyjne"],"techniques_en":["automatic fluorescence analysers"],"techniques_zh":["自动荧光分析仪"],"techniques_cs":["automatickými fluorescenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi\nautomatyczne analizatory fluorescencyjne","reference":"T 22 AA-001 (ČSN EN 14212)","norm_bases":["T 22 AA-001","ČSN EN 14212"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovní ovzduší (imise) Stanovení SO2 automatickými fluorescenčními analyzátory automatickými fluorescenčními analyzátory T 22 AA-001 (ČSN EN 14212) Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovni ovzdusi (imise) Stanoveni SO2 automatickymi fluorescencnimi analyzatory automatickymi fluorescencnimi analyzatory T 22 AA-001 (CSN EN 14212)","search_en":"Ambient air (immissions) Determination of SO2 by automatic fluorescence analysers automatic fluorescence analysers T 22 AA-001 (ČSN EN 14212)","search_zh":"环境空气（环境浓度） 自动荧光分析仪测定SO2 自动荧光分析仪 T 22 AA-001 (ČSN EN 14212)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7acc2cd12be3bf0c506d258c","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"13","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi","methodology_en":"Determination of SO2 by automatic fluorescence analysers","methodology_zh":"自动荧光分析仪测定SO2","methodology_cs":"Stanovení SO2 automatickými fluorescenčními analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fluorescencyjne","technique_en":"automatic fluorescence analysers","technique_zh":"自动荧光分析仪","technique_cs":"automatickými fluorescenčními analyzátory","techniques":["automatyczne analizatory fluorescencyjne"],"techniques_en":["automatic fluorescence analysers"],"techniques_zh":["自动荧光分析仪"],"techniques_cs":["automatickými fluorescenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi\nautomatyczne analizatory fluorescencyjne","reference":"T 22 AA-001 (ČSN EN 14212)","norm_bases":["T 22 AA-001","ČSN EN 14212"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovní ovzduší (imise) Stanovení SO2 automatickými fluorescenčními analyzátory automatickými fluorescenčními analyzátory T 22 AA-001 (ČSN EN 14212) Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovni ovzdusi (imise) Stanoveni SO2 automatickymi fluorescencnimi analyzatory automatickymi fluorescencnimi analyzatory T 22 AA-001 (CSN EN 14212)","search_en":"Ambient air (immissions) Determination of SO2 by automatic fluorescence analysers automatic fluorescence analysers T 22 AA-001 (ČSN EN 14212)","search_zh":"环境空气（环境浓度） 自动荧光分析仪测定SO2 自动荧光分析仪 T 22 AA-001 (ČSN EN 14212)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c08ebb706b25296e516abfc5","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"13","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi","methodology_en":"Determination of SO2 by automatic fluorescence analysers","methodology_zh":"自动荧光分析仪测定SO2","methodology_cs":"Stanovení SO2 automatickými fluorescenčními analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fluorescencyjne","technique_en":"automatic fluorescence analysers","technique_zh":"自动荧光分析仪","technique_cs":"automatickými fluorescenčními analyzátory","techniques":["automatyczne analizatory fluorescencyjne"],"techniques_en":["automatic fluorescence analysers"],"techniques_zh":["自动荧光分析仪"],"techniques_cs":["automatickými fluorescenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi\nautomatyczne analizatory fluorescencyjne","reference":"T 22 AA-001 (ČSN EN 14212)","norm_bases":["T 22 AA-001","ČSN EN 14212"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovní ovzduší (imise) Stanovení SO2 automatickými fluorescenčními analyzátory automatickými fluorescenčními analyzátory T 22 AA-001 (ČSN EN 14212) Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovni ovzdusi (imise) Stanoveni SO2 automatickymi fluorescencnimi analyzatory automatickymi fluorescencnimi analyzatory T 22 AA-001 (CSN EN 14212)","search_en":"Ambient air (immissions) Determination of SO2 by automatic fluorescence analysers automatic fluorescence analysers T 22 AA-001 (ČSN EN 14212)","search_zh":"环境空气（环境浓度） 自动荧光分析仪测定SO2 自动荧光分析仪 T 22 AA-001 (ČSN EN 14212)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7d37e6b79bbbdf7672612f51","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"13","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi","methodology_en":"Determination of SO2 by automatic fluorescence analysers","methodology_zh":"自动荧光分析仪测定SO2","methodology_cs":"Stanovení SO2 automatickými fluorescenčními analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fluorescencyjne","technique_en":"automatic fluorescence analysers","technique_zh":"自动荧光分析仪","technique_cs":"automatickými fluorescenčními analyzátory","techniques":["automatyczne analizatory fluorescencyjne"],"techniques_en":["automatic fluorescence analysers"],"techniques_zh":["自动荧光分析仪"],"techniques_cs":["automatickými fluorescenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi\nautomatyczne analizatory fluorescencyjne","reference":"T 22 AA-001 (ČSN EN 14212)","norm_bases":["T 22 AA-001","ČSN EN 14212"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovní ovzduší (imise) Stanovení SO2 automatickými fluorescenčními analyzátory automatickými fluorescenčními analyzátory T 22 AA-001 (ČSN EN 14212) Powietrze atmosferyczne (imisja) Oznaczanie SO2 automatycznymi analizatorami fluorescencyjnymi automatyczne analizatory fluorescencyjne Venkovni ovzdusi (imise) Stanoveni SO2 automatickymi fluorescencnimi analyzatory automatickymi fluorescencnimi analyzatory T 22 AA-001 (CSN EN 14212)","search_en":"Ambient air (immissions) Determination of SO2 by automatic fluorescence analysers automatic fluorescence analysers T 22 AA-001 (ČSN EN 14212)","search_zh":"环境空气（环境浓度） 自动荧光分析仪测定SO2 自动荧光分析仪 T 22 AA-001 (ČSN EN 14212)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"46c16ef36dd2cd3aeb3a7e56","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"14","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi","methodology_en":"Determination of NO, NO2, NOx by automatic chemiluminescence analysers","methodology_zh":"自动化学发光分析仪测定NO、NO2、NOx","methodology_cs":"Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory","parameters":[{"name":"tlenek azotu (NO)","range":""},{"name":"ditlenek azotu (NO2)","range":""},{"name":"tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"nitrogen monoxide (NO)","range":""},{"name":"nitrogen dioxide (NO2)","range":""},{"name":"nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"一氧化氮（NO）","range":""},{"name":"二氧化氮（NO2）","range":""},{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NO","range":""},{"name":"NO2","range":""},{"name":"NOx","range":""}],"technique":"automatyczne analizatory chemiluminescencyjne","technique_en":"automatic chemiluminescence analysers","technique_zh":"自动化学发光分析仪","technique_cs":"automatickými chemiluminiscenčními analyzátory","techniques":["automatyczne analizatory chemiluminescencyjne"],"techniques_en":["automatic chemiluminescence analysers"],"techniques_zh":["自动化学发光分析仪"],"techniques_cs":["automatickými chemiluminiscenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi\nZakres:\ntlenek azotu (NO)\nditlenek azotu (NO2)\ntlenki azotu (NOx)\nautomatyczne analizatory chemiluminescencyjne","reference":"T 22 AA-002 (ČSN EN 14211)","norm_bases":["T 22 AA-002","ČSN EN 14211"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovní ovzduší (imise) Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory automatickými chemiluminiscenčními analyzátory NO  NO2  NOx  T 22 AA-002 (ČSN EN 14211) Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovni ovzdusi (imise) Stanoveni NO, NO2, NOx automatickymi chemiluminiscencnimi analyzatory automatickymi chemiluminiscencnimi analyzatory NO  NO2  NOx  T 22 AA-002 (CSN EN 14211)","search_en":"Ambient air (immissions) Determination of NO, NO2, NOx by automatic chemiluminescence analysers automatic chemiluminescence analysers nitrogen monoxide (NO)  nitrogen dioxide (NO2)  nitrogen oxides (NOx)  T 22 AA-002 (ČSN EN 14211)","search_zh":"环境空气（环境浓度） 自动化学发光分析仪测定NO、NO2、NOx 自动化学发光分析仪 一氧化氮（NO）  二氧化氮（NO2）  氮氧化物（NOx）  T 22 AA-002 (ČSN EN 14211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3034501d2d239627433980bb","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"14","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi","methodology_en":"Determination of NO, NO2, NOx by automatic chemiluminescence analysers","methodology_zh":"自动化学发光分析仪测定NO、NO2、NOx","methodology_cs":"Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory","parameters":[{"name":"tlenek azotu (NO)","range":""},{"name":"ditlenek azotu (NO2)","range":""},{"name":"tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"nitrogen monoxide (NO)","range":""},{"name":"nitrogen dioxide (NO2)","range":""},{"name":"nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"一氧化氮（NO）","range":""},{"name":"二氧化氮（NO2）","range":""},{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NO","range":""},{"name":"NO2","range":""},{"name":"NOx","range":""}],"technique":"automatyczne analizatory chemiluminescencyjne","technique_en":"automatic chemiluminescence analysers","technique_zh":"自动化学发光分析仪","technique_cs":"automatickými chemiluminiscenčními analyzátory","techniques":["automatyczne analizatory chemiluminescencyjne"],"techniques_en":["automatic chemiluminescence analysers"],"techniques_zh":["自动化学发光分析仪"],"techniques_cs":["automatickými chemiluminiscenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi\nZakres:\ntlenek azotu (NO)\nditlenek azotu (NO2)\ntlenki azotu (NOx)\nautomatyczne analizatory chemiluminescencyjne","reference":"T 22 AA-002 (ČSN EN 14211)","norm_bases":["T 22 AA-002","ČSN EN 14211"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovní ovzduší (imise) Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory automatickými chemiluminiscenčními analyzátory NO  NO2  NOx  T 22 AA-002 (ČSN EN 14211) Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovni ovzdusi (imise) Stanoveni NO, NO2, NOx automatickymi chemiluminiscencnimi analyzatory automatickymi chemiluminiscencnimi analyzatory NO  NO2  NOx  T 22 AA-002 (CSN EN 14211)","search_en":"Ambient air (immissions) Determination of NO, NO2, NOx by automatic chemiluminescence analysers automatic chemiluminescence analysers nitrogen monoxide (NO)  nitrogen dioxide (NO2)  nitrogen oxides (NOx)  T 22 AA-002 (ČSN EN 14211)","search_zh":"环境空气（环境浓度） 自动化学发光分析仪测定NO、NO2、NOx 自动化学发光分析仪 一氧化氮（NO）  二氧化氮（NO2）  氮氧化物（NOx）  T 22 AA-002 (ČSN EN 14211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b854c10ee3906b7775674667","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"14","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi","methodology_en":"Determination of NO, NO2, NOx by automatic chemiluminescence analysers","methodology_zh":"自动化学发光分析仪测定NO、NO2、NOx","methodology_cs":"Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory","parameters":[{"name":"tlenek azotu (NO)","range":""},{"name":"ditlenek azotu (NO2)","range":""},{"name":"tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"nitrogen monoxide (NO)","range":""},{"name":"nitrogen dioxide (NO2)","range":""},{"name":"nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"一氧化氮（NO）","range":""},{"name":"二氧化氮（NO2）","range":""},{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NO","range":""},{"name":"NO2","range":""},{"name":"NOx","range":""}],"technique":"automatyczne analizatory chemiluminescencyjne","technique_en":"automatic chemiluminescence analysers","technique_zh":"自动化学发光分析仪","technique_cs":"automatickými chemiluminiscenčními analyzátory","techniques":["automatyczne analizatory chemiluminescencyjne"],"techniques_en":["automatic chemiluminescence analysers"],"techniques_zh":["自动化学发光分析仪"],"techniques_cs":["automatickými chemiluminiscenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi\nZakres:\ntlenek azotu (NO)\nditlenek azotu (NO2)\ntlenki azotu (NOx)\nautomatyczne analizatory chemiluminescencyjne","reference":"T 22 AA-002 (ČSN EN 14211)","norm_bases":["T 22 AA-002","ČSN EN 14211"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovní ovzduší (imise) Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory automatickými chemiluminiscenčními analyzátory NO  NO2  NOx  T 22 AA-002 (ČSN EN 14211) Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovni ovzdusi (imise) Stanoveni NO, NO2, NOx automatickymi chemiluminiscencnimi analyzatory automatickymi chemiluminiscencnimi analyzatory NO  NO2  NOx  T 22 AA-002 (CSN EN 14211)","search_en":"Ambient air (immissions) Determination of NO, NO2, NOx by automatic chemiluminescence analysers automatic chemiluminescence analysers nitrogen monoxide (NO)  nitrogen dioxide (NO2)  nitrogen oxides (NOx)  T 22 AA-002 (ČSN EN 14211)","search_zh":"环境空气（环境浓度） 自动化学发光分析仪测定NO、NO2、NOx 自动化学发光分析仪 一氧化氮（NO）  二氧化氮（NO2）  氮氧化物（NOx）  T 22 AA-002 (ČSN EN 14211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ecf1edc6db83aa10e64c3a3","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"14","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi","methodology_en":"Determination of NO, NO2, NOx by automatic chemiluminescence analysers","methodology_zh":"自动化学发光分析仪测定NO、NO2、NOx","methodology_cs":"Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory","parameters":[{"name":"tlenek azotu (NO)","range":""},{"name":"ditlenek azotu (NO2)","range":""},{"name":"tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"nitrogen monoxide (NO)","range":""},{"name":"nitrogen dioxide (NO2)","range":""},{"name":"nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"一氧化氮（NO）","range":""},{"name":"二氧化氮（NO2）","range":""},{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NO","range":""},{"name":"NO2","range":""},{"name":"NOx","range":""}],"technique":"automatyczne analizatory chemiluminescencyjne","technique_en":"automatic chemiluminescence analysers","technique_zh":"自动化学发光分析仪","technique_cs":"automatickými chemiluminiscenčními analyzátory","techniques":["automatyczne analizatory chemiluminescencyjne"],"techniques_en":["automatic chemiluminescence analysers"],"techniques_zh":["自动化学发光分析仪"],"techniques_cs":["automatickými chemiluminiscenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi\nZakres:\ntlenek azotu (NO)\nditlenek azotu (NO2)\ntlenki azotu (NOx)\nautomatyczne analizatory chemiluminescencyjne","reference":"T 22 AA-002 (ČSN EN 14211)","norm_bases":["T 22 AA-002","ČSN EN 14211"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovní ovzduší (imise) Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory automatickými chemiluminiscenčními analyzátory NO  NO2  NOx  T 22 AA-002 (ČSN EN 14211) Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovni ovzdusi (imise) Stanoveni NO, NO2, NOx automatickymi chemiluminiscencnimi analyzatory automatickymi chemiluminiscencnimi analyzatory NO  NO2  NOx  T 22 AA-002 (CSN EN 14211)","search_en":"Ambient air (immissions) Determination of NO, NO2, NOx by automatic chemiluminescence analysers automatic chemiluminescence analysers nitrogen monoxide (NO)  nitrogen dioxide (NO2)  nitrogen oxides (NOx)  T 22 AA-002 (ČSN EN 14211)","search_zh":"环境空气（环境浓度） 自动化学发光分析仪测定NO、NO2、NOx 自动化学发光分析仪 一氧化氮（NO）  二氧化氮（NO2）  氮氧化物（NOx）  T 22 AA-002 (ČSN EN 14211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"28e99f9aa3e60a87898ba2f1","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"14","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi","methodology_en":"Determination of NO, NO2, NOx by automatic chemiluminescence analysers","methodology_zh":"自动化学发光分析仪测定NO、NO2、NOx","methodology_cs":"Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory","parameters":[{"name":"tlenek azotu (NO)","range":""},{"name":"ditlenek azotu (NO2)","range":""},{"name":"tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"nitrogen monoxide (NO)","range":""},{"name":"nitrogen dioxide (NO2)","range":""},{"name":"nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"一氧化氮（NO）","range":""},{"name":"二氧化氮（NO2）","range":""},{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NO","range":""},{"name":"NO2","range":""},{"name":"NOx","range":""}],"technique":"automatyczne analizatory chemiluminescencyjne","technique_en":"automatic chemiluminescence analysers","technique_zh":"自动化学发光分析仪","technique_cs":"automatickými chemiluminiscenčními analyzátory","techniques":["automatyczne analizatory chemiluminescencyjne"],"techniques_en":["automatic chemiluminescence analysers"],"techniques_zh":["自动化学发光分析仪"],"techniques_cs":["automatickými chemiluminiscenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi\nZakres:\ntlenek azotu (NO)\nditlenek azotu (NO2)\ntlenki azotu (NOx)\nautomatyczne analizatory chemiluminescencyjne","reference":"T 22 AA-002 (ČSN EN 14211)","norm_bases":["T 22 AA-002","ČSN EN 14211"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovní ovzduší (imise) Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory automatickými chemiluminiscenčními analyzátory NO  NO2  NOx  T 22 AA-002 (ČSN EN 14211) Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovni ovzdusi (imise) Stanoveni NO, NO2, NOx automatickymi chemiluminiscencnimi analyzatory automatickymi chemiluminiscencnimi analyzatory NO  NO2  NOx  T 22 AA-002 (CSN EN 14211)","search_en":"Ambient air (immissions) Determination of NO, NO2, NOx by automatic chemiluminescence analysers automatic chemiluminescence analysers nitrogen monoxide (NO)  nitrogen dioxide (NO2)  nitrogen oxides (NOx)  T 22 AA-002 (ČSN EN 14211)","search_zh":"环境空气（环境浓度） 自动化学发光分析仪测定NO、NO2、NOx 自动化学发光分析仪 一氧化氮（NO）  二氧化氮（NO2）  氮氧化物（NOx）  T 22 AA-002 (ČSN EN 14211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1bd2feaa1428cc32ba3f3d40","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"14","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi","methodology_en":"Determination of NO, NO2, NOx by automatic chemiluminescence analysers","methodology_zh":"自动化学发光分析仪测定NO、NO2、NOx","methodology_cs":"Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory","parameters":[{"name":"tlenek azotu (NO)","range":""},{"name":"ditlenek azotu (NO2)","range":""},{"name":"tlenki azotu (NOx)","range":""}],"parameters_en":[{"name":"nitrogen monoxide (NO)","range":""},{"name":"nitrogen dioxide (NO2)","range":""},{"name":"nitrogen oxides (NOx)","range":""}],"parameters_zh":[{"name":"一氧化氮（NO）","range":""},{"name":"二氧化氮（NO2）","range":""},{"name":"氮氧化物（NOx）","range":""}],"parameters_cs":[{"name":"NO","range":""},{"name":"NO2","range":""},{"name":"NOx","range":""}],"technique":"automatyczne analizatory chemiluminescencyjne","technique_en":"automatic chemiluminescence analysers","technique_zh":"自动化学发光分析仪","technique_cs":"automatickými chemiluminiscenčními analyzátory","techniques":["automatyczne analizatory chemiluminescencyjne"],"techniques_en":["automatic chemiluminescence analysers"],"techniques_zh":["自动化学发光分析仪"],"techniques_cs":["automatickými chemiluminiscenčními analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi\nZakres:\ntlenek azotu (NO)\nditlenek azotu (NO2)\ntlenki azotu (NOx)\nautomatyczne analizatory chemiluminescencyjne","reference":"T 22 AA-002 (ČSN EN 14211)","norm_bases":["T 22 AA-002","ČSN EN 14211"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovní ovzduší (imise) Stanovení NO, NO2, NOx automatickými chemiluminiscenčními analyzátory automatickými chemiluminiscenčními analyzátory NO  NO2  NOx  T 22 AA-002 (ČSN EN 14211) Powietrze atmosferyczne (imisja) Oznaczanie NO, NO2, NOx automatycznymi analizatorami chemiluminescencyjnymi automatyczne analizatory chemiluminescencyjne tlenek azotu (NO)  ditlenek azotu (NO2)  tlenki azotu (NOx)  Venkovni ovzdusi (imise) Stanoveni NO, NO2, NOx automatickymi chemiluminiscencnimi analyzatory automatickymi chemiluminiscencnimi analyzatory NO  NO2  NOx  T 22 AA-002 (CSN EN 14211)","search_en":"Ambient air (immissions) Determination of NO, NO2, NOx by automatic chemiluminescence analysers automatic chemiluminescence analysers nitrogen monoxide (NO)  nitrogen dioxide (NO2)  nitrogen oxides (NOx)  T 22 AA-002 (ČSN EN 14211)","search_zh":"环境空气（环境浓度） 自动化学发光分析仪测定NO、NO2、NOx 自动化学发光分析仪 一氧化氮（NO）  二氧化氮（NO2）  氮氧化物（NOx）  T 22 AA-002 (ČSN EN 14211)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"24ad636beccc5c6876d7345e","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"15","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni","methodology_en":"Determination of CO by automatic analysers using non-dispersive infrared spectrometry","methodology_zh":"非分散红外光谱法自动分析仪测定CO","methodology_cs":"Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","technique_en":"automatic analysers, non-dispersive infrared spectrometry","technique_zh":"自动分析仪，非分散红外光谱法","technique_cs":"automatickými analyzátory metodou nedisperzní infračervené spektrometrie","techniques":["automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni"],"techniques_en":["automatic analysers, non-dispersive infrared spectrometry"],"techniques_zh":["自动分析仪，非分散红外光谱法"],"techniques_cs":["automatickými analyzátory metodou nedisperzní infračervené spektrometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni\nautomatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","reference":"T 22 AA-004 (ČSN EN 14626)","norm_bases":["T 22 AA-004","ČSN EN 14626"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovní ovzduší (imise) Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie automatickými analyzátory metodou nedisperzní infračervené spektrometrie T 22 AA-004 (ČSN EN 14626) Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metoda niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovni ovzdusi (imise) Stanoveni CO automatickymi analyzatory metodou nedisperzni infracervene spektrometrie automatickymi analyzatory metodou nedisperzni infracervene spektrometrie T 22 AA-004 (CSN EN 14626)","search_en":"Ambient air (immissions) Determination of CO by automatic analysers using non-dispersive infrared spectrometry automatic analysers, non-dispersive infrared spectrometry T 22 AA-004 (ČSN EN 14626)","search_zh":"环境空气（环境浓度） 非分散红外光谱法自动分析仪测定CO 自动分析仪，非分散红外光谱法 T 22 AA-004 (ČSN EN 14626)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"72c7a07619e549c0fa2e5368","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"15","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni","methodology_en":"Determination of CO by automatic analysers using non-dispersive infrared spectrometry","methodology_zh":"非分散红外光谱法自动分析仪测定CO","methodology_cs":"Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","technique_en":"automatic analysers, non-dispersive infrared spectrometry","technique_zh":"自动分析仪，非分散红外光谱法","technique_cs":"automatickými analyzátory metodou nedisperzní infračervené spektrometrie","techniques":["automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni"],"techniques_en":["automatic analysers, non-dispersive infrared spectrometry"],"techniques_zh":["自动分析仪，非分散红外光谱法"],"techniques_cs":["automatickými analyzátory metodou nedisperzní infračervené spektrometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni\nautomatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","reference":"T 22 AA-004 (ČSN EN 14626)","norm_bases":["T 22 AA-004","ČSN EN 14626"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovní ovzduší (imise) Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie automatickými analyzátory metodou nedisperzní infračervené spektrometrie T 22 AA-004 (ČSN EN 14626) Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metoda niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovni ovzdusi (imise) Stanoveni CO automatickymi analyzatory metodou nedisperzni infracervene spektrometrie automatickymi analyzatory metodou nedisperzni infracervene spektrometrie T 22 AA-004 (CSN EN 14626)","search_en":"Ambient air (immissions) Determination of CO by automatic analysers using non-dispersive infrared spectrometry automatic analysers, non-dispersive infrared spectrometry T 22 AA-004 (ČSN EN 14626)","search_zh":"环境空气（环境浓度） 非分散红外光谱法自动分析仪测定CO 自动分析仪，非分散红外光谱法 T 22 AA-004 (ČSN EN 14626)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"44dbfa7eb491b33fc9334d26","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"15","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni","methodology_en":"Determination of CO by automatic analysers using non-dispersive infrared spectrometry","methodology_zh":"非分散红外光谱法自动分析仪测定CO","methodology_cs":"Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","technique_en":"automatic analysers, non-dispersive infrared spectrometry","technique_zh":"自动分析仪，非分散红外光谱法","technique_cs":"automatickými analyzátory metodou nedisperzní infračervené spektrometrie","techniques":["automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni"],"techniques_en":["automatic analysers, non-dispersive infrared spectrometry"],"techniques_zh":["自动分析仪，非分散红外光谱法"],"techniques_cs":["automatickými analyzátory metodou nedisperzní infračervené spektrometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni\nautomatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","reference":"T 22 AA-004 (ČSN EN 14626)","norm_bases":["T 22 AA-004","ČSN EN 14626"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovní ovzduší (imise) Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie automatickými analyzátory metodou nedisperzní infračervené spektrometrie T 22 AA-004 (ČSN EN 14626) Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metoda niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovni ovzdusi (imise) Stanoveni CO automatickymi analyzatory metodou nedisperzni infracervene spektrometrie automatickymi analyzatory metodou nedisperzni infracervene spektrometrie T 22 AA-004 (CSN EN 14626)","search_en":"Ambient air (immissions) Determination of CO by automatic analysers using non-dispersive infrared spectrometry automatic analysers, non-dispersive infrared spectrometry T 22 AA-004 (ČSN EN 14626)","search_zh":"环境空气（环境浓度） 非分散红外光谱法自动分析仪测定CO 自动分析仪，非分散红外光谱法 T 22 AA-004 (ČSN EN 14626)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a9e080798dd21a0a4d00f3c8","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"15","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni","methodology_en":"Determination of CO by automatic analysers using non-dispersive infrared spectrometry","methodology_zh":"非分散红外光谱法自动分析仪测定CO","methodology_cs":"Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","technique_en":"automatic analysers, non-dispersive infrared spectrometry","technique_zh":"自动分析仪，非分散红外光谱法","technique_cs":"automatickými analyzátory metodou nedisperzní infračervené spektrometrie","techniques":["automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni"],"techniques_en":["automatic analysers, non-dispersive infrared spectrometry"],"techniques_zh":["自动分析仪，非分散红外光谱法"],"techniques_cs":["automatickými analyzátory metodou nedisperzní infračervené spektrometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni\nautomatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","reference":"T 22 AA-004 (ČSN EN 14626)","norm_bases":["T 22 AA-004","ČSN EN 14626"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovní ovzduší (imise) Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie automatickými analyzátory metodou nedisperzní infračervené spektrometrie T 22 AA-004 (ČSN EN 14626) Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metoda niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovni ovzdusi (imise) Stanoveni CO automatickymi analyzatory metodou nedisperzni infracervene spektrometrie automatickymi analyzatory metodou nedisperzni infracervene spektrometrie T 22 AA-004 (CSN EN 14626)","search_en":"Ambient air (immissions) Determination of CO by automatic analysers using non-dispersive infrared spectrometry automatic analysers, non-dispersive infrared spectrometry T 22 AA-004 (ČSN EN 14626)","search_zh":"环境空气（环境浓度） 非分散红外光谱法自动分析仪测定CO 自动分析仪，非分散红外光谱法 T 22 AA-004 (ČSN EN 14626)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a01991b6c844980602dfcf46","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"15","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni","methodology_en":"Determination of CO by automatic analysers using non-dispersive infrared spectrometry","methodology_zh":"非分散红外光谱法自动分析仪测定CO","methodology_cs":"Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","technique_en":"automatic analysers, non-dispersive infrared spectrometry","technique_zh":"自动分析仪，非分散红外光谱法","technique_cs":"automatickými analyzátory metodou nedisperzní infračervené spektrometrie","techniques":["automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni"],"techniques_en":["automatic analysers, non-dispersive infrared spectrometry"],"techniques_zh":["自动分析仪，非分散红外光谱法"],"techniques_cs":["automatickými analyzátory metodou nedisperzní infračervené spektrometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni\nautomatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","reference":"T 22 AA-004 (ČSN EN 14626)","norm_bases":["T 22 AA-004","ČSN EN 14626"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovní ovzduší (imise) Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie automatickými analyzátory metodou nedisperzní infračervené spektrometrie T 22 AA-004 (ČSN EN 14626) Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metoda niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovni ovzdusi (imise) Stanoveni CO automatickymi analyzatory metodou nedisperzni infracervene spektrometrie automatickymi analyzatory metodou nedisperzni infracervene spektrometrie T 22 AA-004 (CSN EN 14626)","search_en":"Ambient air (immissions) Determination of CO by automatic analysers using non-dispersive infrared spectrometry automatic analysers, non-dispersive infrared spectrometry T 22 AA-004 (ČSN EN 14626)","search_zh":"环境空气（环境浓度） 非分散红外光谱法自动分析仪测定CO 自动分析仪，非分散红外光谱法 T 22 AA-004 (ČSN EN 14626)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"55f019eb3f048701b4451f3d","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"15","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni","methodology_en":"Determination of CO by automatic analysers using non-dispersive infrared spectrometry","methodology_zh":"非分散红外光谱法自动分析仪测定CO","methodology_cs":"Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","technique_en":"automatic analysers, non-dispersive infrared spectrometry","technique_zh":"自动分析仪，非分散红外光谱法","technique_cs":"automatickými analyzátory metodou nedisperzní infračervené spektrometrie","techniques":["automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni"],"techniques_en":["automatic analysers, non-dispersive infrared spectrometry"],"techniques_zh":["自动分析仪，非分散红外光谱法"],"techniques_cs":["automatickými analyzátory metodou nedisperzní infračervené spektrometrie"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni\nautomatyczne analizatory, niedyspersyjna spektrometria w podczerwieni","reference":"T 22 AA-004 (ČSN EN 14626)","norm_bases":["T 22 AA-004","ČSN EN 14626"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metodą niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovní ovzduší (imise) Stanovení CO automatickými analyzátory metodou nedisperzní infračervené spektrometrie automatickými analyzátory metodou nedisperzní infračervené spektrometrie T 22 AA-004 (ČSN EN 14626) Powietrze atmosferyczne (imisja) Oznaczanie CO automatycznymi analizatorami metoda niedyspersyjnej spektrometrii w podczerwieni automatyczne analizatory, niedyspersyjna spektrometria w podczerwieni Venkovni ovzdusi (imise) Stanoveni CO automatickymi analyzatory metodou nedisperzni infracervene spektrometrie automatickymi analyzatory metodou nedisperzni infracervene spektrometrie T 22 AA-004 (CSN EN 14626)","search_en":"Ambient air (immissions) Determination of CO by automatic analysers using non-dispersive infrared spectrometry automatic analysers, non-dispersive infrared spectrometry T 22 AA-004 (ČSN EN 14626)","search_zh":"环境空气（环境浓度） 非分散红外光谱法自动分析仪测定CO 自动分析仪，非分散红外光谱法 T 22 AA-004 (ČSN EN 14626)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc749c1d468726c72e99cae5","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"16","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi","methodology_en":"Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors","methodology_zh":"自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne pyłomierze beta i optyczne","technique_en":"automatic beta and optical dust monitors","technique_zh":"自动β射线和光学粉尘仪","technique_cs":"automatickými beta a optickými prachoměry","techniques":["automatyczne pyłomierze beta i optyczne"],"techniques_en":["automatic beta and optical dust monitors"],"techniques_zh":["自动β射线和光学粉尘仪"],"techniques_cs":["automatickými beta a optickými prachoměry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi\nautomatyczne pyłomierze beta i optyczne","reference":"T 22 AA-005 (ČSN EN 16450)","norm_bases":["T 22 AA-005","ČSN EN 16450"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi automatyczne pyłomierze beta i optyczne Venkovní ovzduší (imise) Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry automatickými beta a optickými prachoměry T 22 AA-005 (ČSN EN 16450) Powietrze atmosferyczne (imisja) Oznaczanie czastek aerozolu (PM10 i PM2,5) automatycznymi pylomierzami beta i optycznymi automatyczne pylomierze beta i optyczne Venkovni ovzdusi (imise) Stanoveni aerosolovych castic (PM10 a PM2,5) automatickymi beta a optickymi prachomery automatickymi beta a optickymi prachomery T 22 AA-005 (CSN EN 16450)","search_en":"Ambient air (immissions) Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors automatic beta and optical dust monitors T 22 AA-005 (ČSN EN 16450)","search_zh":"环境空气（环境浓度） 自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5） 自动β射线和光学粉尘仪 T 22 AA-005 (ČSN EN 16450)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b63d5909fbfc3b0089b55414","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"16","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi","methodology_en":"Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors","methodology_zh":"自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne pyłomierze beta i optyczne","technique_en":"automatic beta and optical dust monitors","technique_zh":"自动β射线和光学粉尘仪","technique_cs":"automatickými beta a optickými prachoměry","techniques":["automatyczne pyłomierze beta i optyczne"],"techniques_en":["automatic beta and optical dust monitors"],"techniques_zh":["自动β射线和光学粉尘仪"],"techniques_cs":["automatickými beta a optickými prachoměry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi\nautomatyczne pyłomierze beta i optyczne","reference":"T 22 AA-005 (ČSN EN 16450)","norm_bases":["T 22 AA-005","ČSN EN 16450"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi automatyczne pyłomierze beta i optyczne Venkovní ovzduší (imise) Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry automatickými beta a optickými prachoměry T 22 AA-005 (ČSN EN 16450) Powietrze atmosferyczne (imisja) Oznaczanie czastek aerozolu (PM10 i PM2,5) automatycznymi pylomierzami beta i optycznymi automatyczne pylomierze beta i optyczne Venkovni ovzdusi (imise) Stanoveni aerosolovych castic (PM10 a PM2,5) automatickymi beta a optickymi prachomery automatickymi beta a optickymi prachomery T 22 AA-005 (CSN EN 16450)","search_en":"Ambient air (immissions) Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors automatic beta and optical dust monitors T 22 AA-005 (ČSN EN 16450)","search_zh":"环境空气（环境浓度） 自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5） 自动β射线和光学粉尘仪 T 22 AA-005 (ČSN EN 16450)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb06623bdc57eb294484e85e","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"16","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi","methodology_en":"Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors","methodology_zh":"自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne pyłomierze beta i optyczne","technique_en":"automatic beta and optical dust monitors","technique_zh":"自动β射线和光学粉尘仪","technique_cs":"automatickými beta a optickými prachoměry","techniques":["automatyczne pyłomierze beta i optyczne"],"techniques_en":["automatic beta and optical dust monitors"],"techniques_zh":["自动β射线和光学粉尘仪"],"techniques_cs":["automatickými beta a optickými prachoměry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi\nautomatyczne pyłomierze beta i optyczne","reference":"T 22 AA-005 (ČSN EN 16450)","norm_bases":["T 22 AA-005","ČSN EN 16450"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi automatyczne pyłomierze beta i optyczne Venkovní ovzduší (imise) Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry automatickými beta a optickými prachoměry T 22 AA-005 (ČSN EN 16450) Powietrze atmosferyczne (imisja) Oznaczanie czastek aerozolu (PM10 i PM2,5) automatycznymi pylomierzami beta i optycznymi automatyczne pylomierze beta i optyczne Venkovni ovzdusi (imise) Stanoveni aerosolovych castic (PM10 a PM2,5) automatickymi beta a optickymi prachomery automatickymi beta a optickymi prachomery T 22 AA-005 (CSN EN 16450)","search_en":"Ambient air (immissions) Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors automatic beta and optical dust monitors T 22 AA-005 (ČSN EN 16450)","search_zh":"环境空气（环境浓度） 自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5） 自动β射线和光学粉尘仪 T 22 AA-005 (ČSN EN 16450)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"22b63af7c1121b10c26138e1","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"16","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi","methodology_en":"Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors","methodology_zh":"自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne pyłomierze beta i optyczne","technique_en":"automatic beta and optical dust monitors","technique_zh":"自动β射线和光学粉尘仪","technique_cs":"automatickými beta a optickými prachoměry","techniques":["automatyczne pyłomierze beta i optyczne"],"techniques_en":["automatic beta and optical dust monitors"],"techniques_zh":["自动β射线和光学粉尘仪"],"techniques_cs":["automatickými beta a optickými prachoměry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi\nautomatyczne pyłomierze beta i optyczne","reference":"T 22 AA-005 (ČSN EN 16450)","norm_bases":["T 22 AA-005","ČSN EN 16450"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi automatyczne pyłomierze beta i optyczne Venkovní ovzduší (imise) Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry automatickými beta a optickými prachoměry T 22 AA-005 (ČSN EN 16450) Powietrze atmosferyczne (imisja) Oznaczanie czastek aerozolu (PM10 i PM2,5) automatycznymi pylomierzami beta i optycznymi automatyczne pylomierze beta i optyczne Venkovni ovzdusi (imise) Stanoveni aerosolovych castic (PM10 a PM2,5) automatickymi beta a optickymi prachomery automatickymi beta a optickymi prachomery T 22 AA-005 (CSN EN 16450)","search_en":"Ambient air (immissions) Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors automatic beta and optical dust monitors T 22 AA-005 (ČSN EN 16450)","search_zh":"环境空气（环境浓度） 自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5） 自动β射线和光学粉尘仪 T 22 AA-005 (ČSN EN 16450)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2ec47506a3337fd09cbe5c63","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"16","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi","methodology_en":"Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors","methodology_zh":"自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne pyłomierze beta i optyczne","technique_en":"automatic beta and optical dust monitors","technique_zh":"自动β射线和光学粉尘仪","technique_cs":"automatickými beta a optickými prachoměry","techniques":["automatyczne pyłomierze beta i optyczne"],"techniques_en":["automatic beta and optical dust monitors"],"techniques_zh":["自动β射线和光学粉尘仪"],"techniques_cs":["automatickými beta a optickými prachoměry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi\nautomatyczne pyłomierze beta i optyczne","reference":"T 22 AA-005 (ČSN EN 16450)","norm_bases":["T 22 AA-005","ČSN EN 16450"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi automatyczne pyłomierze beta i optyczne Venkovní ovzduší (imise) Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry automatickými beta a optickými prachoměry T 22 AA-005 (ČSN EN 16450) Powietrze atmosferyczne (imisja) Oznaczanie czastek aerozolu (PM10 i PM2,5) automatycznymi pylomierzami beta i optycznymi automatyczne pylomierze beta i optyczne Venkovni ovzdusi (imise) Stanoveni aerosolovych castic (PM10 a PM2,5) automatickymi beta a optickymi prachomery automatickymi beta a optickymi prachomery T 22 AA-005 (CSN EN 16450)","search_en":"Ambient air (immissions) Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors automatic beta and optical dust monitors T 22 AA-005 (ČSN EN 16450)","search_zh":"环境空气（环境浓度） 自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5） 自动β射线和光学粉尘仪 T 22 AA-005 (ČSN EN 16450)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9c376b07350d3ce19bf1e1aa","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"16","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi","methodology_en":"Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors","methodology_zh":"自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5）","methodology_cs":"Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne pyłomierze beta i optyczne","technique_en":"automatic beta and optical dust monitors","technique_zh":"自动β射线和光学粉尘仪","technique_cs":"automatickými beta a optickými prachoměry","techniques":["automatyczne pyłomierze beta i optyczne"],"techniques_en":["automatic beta and optical dust monitors"],"techniques_zh":["自动β射线和光学粉尘仪"],"techniques_cs":["automatickými beta a optickými prachoměry"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi\nautomatyczne pyłomierze beta i optyczne","reference":"T 22 AA-005 (ČSN EN 16450)","norm_bases":["T 22 AA-005","ČSN EN 16450"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie cząstek aerozolu (PM10 i PM2,5) automatycznymi pyłomierzami beta i optycznymi automatyczne pyłomierze beta i optyczne Venkovní ovzduší (imise) Stanovení aerosolových částic (PM10 a PM2,5) automatickými beta a optickými prachoměry automatickými beta a optickými prachoměry T 22 AA-005 (ČSN EN 16450) Powietrze atmosferyczne (imisja) Oznaczanie czastek aerozolu (PM10 i PM2,5) automatycznymi pylomierzami beta i optycznymi automatyczne pylomierze beta i optyczne Venkovni ovzdusi (imise) Stanoveni aerosolovych castic (PM10 a PM2,5) automatickymi beta a optickymi prachomery automatickymi beta a optickymi prachomery T 22 AA-005 (CSN EN 16450)","search_en":"Ambient air (immissions) Determination of aerosol particles (PM10 and PM2.5) by automatic beta and optical dust monitors automatic beta and optical dust monitors T 22 AA-005 (ČSN EN 16450)","search_zh":"环境空气（环境浓度） 自动β射线和光学粉尘仪测定气溶胶颗粒（PM10和PM2.5） 自动β射线和光学粉尘仪 T 22 AA-005 (ČSN EN 16450)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"99863c8f63363db754dea4c4","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"17","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID","methodology_en":"Determination of benzene and toluene by automatic analysers using GC-PID","methodology_zh":"GC-PID法自动分析仪测定苯和甲苯","methodology_cs":"Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","technique_en":"automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)","technique_zh":"自动分析仪，气相色谱-光离子化检测法（GC-PID）","technique_cs":"automatickými analyzátory metodou GC-PID","techniques":["automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)"],"techniques_en":["automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)"],"techniques_zh":["自动分析仪，气相色谱-光离子化检测法（GC-PID）"],"techniques_cs":["automatickými analyzátory metodou GC-PID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID\nautomatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","reference":"T 22 AA-007 (ČSN EN 14662-3)","norm_bases":["T 22 AA-007","ČSN EN 14662-3"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovní ovzduší (imise) Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID automatickými analyzátory metodou GC-PID T 22 AA-007 (ČSN EN 14662-3) Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metoda GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovni ovzdusi (imise) Stanoveni benzenu a toluenu automatickymi analyzatory metodou GC-PID automatickymi analyzatory metodou GC-PID T 22 AA-007 (CSN EN 14662-3)","search_en":"Ambient air (immissions) Determination of benzene and toluene by automatic analysers using GC-PID automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) T 22 AA-007 (ČSN EN 14662-3)","search_zh":"环境空气（环境浓度） GC-PID法自动分析仪测定苯和甲苯 自动分析仪，气相色谱-光离子化检测法（GC-PID） T 22 AA-007 (ČSN EN 14662-3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"587251de83612971c2763acd","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"17","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID","methodology_en":"Determination of benzene and toluene by automatic analysers using GC-PID","methodology_zh":"GC-PID法自动分析仪测定苯和甲苯","methodology_cs":"Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","technique_en":"automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)","technique_zh":"自动分析仪，气相色谱-光离子化检测法（GC-PID）","technique_cs":"automatickými analyzátory metodou GC-PID","techniques":["automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)"],"techniques_en":["automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)"],"techniques_zh":["自动分析仪，气相色谱-光离子化检测法（GC-PID）"],"techniques_cs":["automatickými analyzátory metodou GC-PID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID\nautomatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","reference":"T 22 AA-007 (ČSN EN 14662-3)","norm_bases":["T 22 AA-007","ČSN EN 14662-3"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovní ovzduší (imise) Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID automatickými analyzátory metodou GC-PID T 22 AA-007 (ČSN EN 14662-3) Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metoda GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovni ovzdusi (imise) Stanoveni benzenu a toluenu automatickymi analyzatory metodou GC-PID automatickymi analyzatory metodou GC-PID T 22 AA-007 (CSN EN 14662-3)","search_en":"Ambient air (immissions) Determination of benzene and toluene by automatic analysers using GC-PID automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) T 22 AA-007 (ČSN EN 14662-3)","search_zh":"环境空气（环境浓度） GC-PID法自动分析仪测定苯和甲苯 自动分析仪，气相色谱-光离子化检测法（GC-PID） T 22 AA-007 (ČSN EN 14662-3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6492662d37092c4a3bdefa80","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"17","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID","methodology_en":"Determination of benzene and toluene by automatic analysers using GC-PID","methodology_zh":"GC-PID法自动分析仪测定苯和甲苯","methodology_cs":"Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","technique_en":"automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)","technique_zh":"自动分析仪，气相色谱-光离子化检测法（GC-PID）","technique_cs":"automatickými analyzátory metodou GC-PID","techniques":["automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)"],"techniques_en":["automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)"],"techniques_zh":["自动分析仪，气相色谱-光离子化检测法（GC-PID）"],"techniques_cs":["automatickými analyzátory metodou GC-PID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID\nautomatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","reference":"T 22 AA-007 (ČSN EN 14662-3)","norm_bases":["T 22 AA-007","ČSN EN 14662-3"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovní ovzduší (imise) Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID automatickými analyzátory metodou GC-PID T 22 AA-007 (ČSN EN 14662-3) Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metoda GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovni ovzdusi (imise) Stanoveni benzenu a toluenu automatickymi analyzatory metodou GC-PID automatickymi analyzatory metodou GC-PID T 22 AA-007 (CSN EN 14662-3)","search_en":"Ambient air (immissions) Determination of benzene and toluene by automatic analysers using GC-PID automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) T 22 AA-007 (ČSN EN 14662-3)","search_zh":"环境空气（环境浓度） GC-PID法自动分析仪测定苯和甲苯 自动分析仪，气相色谱-光离子化检测法（GC-PID） T 22 AA-007 (ČSN EN 14662-3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4ae69a788abb763c2a21f9ab","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"17","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID","methodology_en":"Determination of benzene and toluene by automatic analysers using GC-PID","methodology_zh":"GC-PID法自动分析仪测定苯和甲苯","methodology_cs":"Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","technique_en":"automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)","technique_zh":"自动分析仪，气相色谱-光离子化检测法（GC-PID）","technique_cs":"automatickými analyzátory metodou GC-PID","techniques":["automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)"],"techniques_en":["automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)"],"techniques_zh":["自动分析仪，气相色谱-光离子化检测法（GC-PID）"],"techniques_cs":["automatickými analyzátory metodou GC-PID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID\nautomatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","reference":"T 22 AA-007 (ČSN EN 14662-3)","norm_bases":["T 22 AA-007","ČSN EN 14662-3"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovní ovzduší (imise) Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID automatickými analyzátory metodou GC-PID T 22 AA-007 (ČSN EN 14662-3) Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metoda GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovni ovzdusi (imise) Stanoveni benzenu a toluenu automatickymi analyzatory metodou GC-PID automatickymi analyzatory metodou GC-PID T 22 AA-007 (CSN EN 14662-3)","search_en":"Ambient air (immissions) Determination of benzene and toluene by automatic analysers using GC-PID automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) T 22 AA-007 (ČSN EN 14662-3)","search_zh":"环境空气（环境浓度） GC-PID法自动分析仪测定苯和甲苯 自动分析仪，气相色谱-光离子化检测法（GC-PID） T 22 AA-007 (ČSN EN 14662-3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"693f702650b8e4d45429cf5a","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"17","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID","methodology_en":"Determination of benzene and toluene by automatic analysers using GC-PID","methodology_zh":"GC-PID法自动分析仪测定苯和甲苯","methodology_cs":"Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","technique_en":"automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)","technique_zh":"自动分析仪，气相色谱-光离子化检测法（GC-PID）","technique_cs":"automatickými analyzátory metodou GC-PID","techniques":["automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)"],"techniques_en":["automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)"],"techniques_zh":["自动分析仪，气相色谱-光离子化检测法（GC-PID）"],"techniques_cs":["automatickými analyzátory metodou GC-PID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID\nautomatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","reference":"T 22 AA-007 (ČSN EN 14662-3)","norm_bases":["T 22 AA-007","ČSN EN 14662-3"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovní ovzduší (imise) Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID automatickými analyzátory metodou GC-PID T 22 AA-007 (ČSN EN 14662-3) Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metoda GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovni ovzdusi (imise) Stanoveni benzenu a toluenu automatickymi analyzatory metodou GC-PID automatickymi analyzatory metodou GC-PID T 22 AA-007 (CSN EN 14662-3)","search_en":"Ambient air (immissions) Determination of benzene and toluene by automatic analysers using GC-PID automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) T 22 AA-007 (ČSN EN 14662-3)","search_zh":"环境空气（环境浓度） GC-PID法自动分析仪测定苯和甲苯 自动分析仪，气相色谱-光离子化检测法（GC-PID） T 22 AA-007 (ČSN EN 14662-3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d389355658ff9c8fb6f412ba","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"17","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID","methodology_en":"Determination of benzene and toluene by automatic analysers using GC-PID","methodology_zh":"GC-PID法自动分析仪测定苯和甲苯","methodology_cs":"Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","technique_en":"automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)","technique_zh":"自动分析仪，气相色谱-光离子化检测法（GC-PID）","technique_cs":"automatickými analyzátory metodou GC-PID","techniques":["automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)"],"techniques_en":["automatic analysers, gas chromatography with photo-ionisation detector (GC-PID)"],"techniques_zh":["自动分析仪，气相色谱-光离子化检测法（GC-PID）"],"techniques_cs":["automatickými analyzátory metodou GC-PID"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID\nautomatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID)","reference":"T 22 AA-007 (ČSN EN 14662-3)","norm_bases":["T 22 AA-007","ČSN EN 14662-3"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metodą GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovní ovzduší (imise) Stanovení benzenu a toluenu automatickými analyzátory metodou GC-PID automatickými analyzátory metodou GC-PID T 22 AA-007 (ČSN EN 14662-3) Powietrze atmosferyczne (imisja) Oznaczanie benzenu i toluenu automatycznymi analizatorami metoda GC-PID automatyczne analizatory, chromatografia gazowa z detektorem fotojonizacyjnym (GC-PID) Venkovni ovzdusi (imise) Stanoveni benzenu a toluenu automatickymi analyzatory metodou GC-PID automatickymi analyzatory metodou GC-PID T 22 AA-007 (CSN EN 14662-3)","search_en":"Ambient air (immissions) Determination of benzene and toluene by automatic analysers using GC-PID automatic analysers, gas chromatography with photo-ionisation detector (GC-PID) T 22 AA-007 (ČSN EN 14662-3)","search_zh":"环境空气（环境浓度） GC-PID法自动分析仪测定苯和甲苯 自动分析仪，气相色谱-光离子化检测法（GC-PID） T 22 AA-007 (ČSN EN 14662-3)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b633abd64897a9c539c7e600","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"18","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie","methodology_en":"Determination of O3 by automatic ultraviolet photometric analysers","methodology_zh":"自动紫外光度分析仪测定O3","methodology_cs":"Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fotometryczne w nadfiolecie","technique_en":"automatic ultraviolet photometric analysers","technique_zh":"自动紫外光度分析仪","technique_cs":"automatickými ultrafialovými fotometrickými analyzátory","techniques":["automatyczne analizatory fotometryczne w nadfiolecie"],"techniques_en":["automatic ultraviolet photometric analysers"],"techniques_zh":["自动紫外光度分析仪"],"techniques_cs":["automatickými ultrafialovými fotometrickými analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie\nautomatyczne analizatory fotometryczne w nadfiolecie","reference":"T 22 AA-010 (ČSN EN 14625)","norm_bases":["T 22 AA-010","ČSN EN 14625"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovní ovzduší (imise) Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory automatickými ultrafialovými fotometrickými analyzátory T 22 AA-010 (ČSN EN 14625) Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovni ovzdusi (imise) Stanoveni O3 automatickymi ultrafialovymi fotometrickymi analyzatory automatickymi ultrafialovymi fotometrickymi analyzatory T 22 AA-010 (CSN EN 14625)","search_en":"Ambient air (immissions) Determination of O3 by automatic ultraviolet photometric analysers automatic ultraviolet photometric analysers T 22 AA-010 (ČSN EN 14625)","search_zh":"环境空气（环境浓度） 自动紫外光度分析仪测定O3 自动紫外光度分析仪 T 22 AA-010 (ČSN EN 14625)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fbf676754a37b9295b75af22","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"18","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie","methodology_en":"Determination of O3 by automatic ultraviolet photometric analysers","methodology_zh":"自动紫外光度分析仪测定O3","methodology_cs":"Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fotometryczne w nadfiolecie","technique_en":"automatic ultraviolet photometric analysers","technique_zh":"自动紫外光度分析仪","technique_cs":"automatickými ultrafialovými fotometrickými analyzátory","techniques":["automatyczne analizatory fotometryczne w nadfiolecie"],"techniques_en":["automatic ultraviolet photometric analysers"],"techniques_zh":["自动紫外光度分析仪"],"techniques_cs":["automatickými ultrafialovými fotometrickými analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie\nautomatyczne analizatory fotometryczne w nadfiolecie","reference":"T 22 AA-010 (ČSN EN 14625)","norm_bases":["T 22 AA-010","ČSN EN 14625"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovní ovzduší (imise) Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory automatickými ultrafialovými fotometrickými analyzátory T 22 AA-010 (ČSN EN 14625) Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovni ovzdusi (imise) Stanoveni O3 automatickymi ultrafialovymi fotometrickymi analyzatory automatickymi ultrafialovymi fotometrickymi analyzatory T 22 AA-010 (CSN EN 14625)","search_en":"Ambient air (immissions) Determination of O3 by automatic ultraviolet photometric analysers automatic ultraviolet photometric analysers T 22 AA-010 (ČSN EN 14625)","search_zh":"环境空气（环境浓度） 自动紫外光度分析仪测定O3 自动紫外光度分析仪 T 22 AA-010 (ČSN EN 14625)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd8a4c9b84850f0b15dd986c","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"18","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie","methodology_en":"Determination of O3 by automatic ultraviolet photometric analysers","methodology_zh":"自动紫外光度分析仪测定O3","methodology_cs":"Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fotometryczne w nadfiolecie","technique_en":"automatic ultraviolet photometric analysers","technique_zh":"自动紫外光度分析仪","technique_cs":"automatickými ultrafialovými fotometrickými analyzátory","techniques":["automatyczne analizatory fotometryczne w nadfiolecie"],"techniques_en":["automatic ultraviolet photometric analysers"],"techniques_zh":["自动紫外光度分析仪"],"techniques_cs":["automatickými ultrafialovými fotometrickými analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie\nautomatyczne analizatory fotometryczne w nadfiolecie","reference":"T 22 AA-010 (ČSN EN 14625)","norm_bases":["T 22 AA-010","ČSN EN 14625"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovní ovzduší (imise) Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory automatickými ultrafialovými fotometrickými analyzátory T 22 AA-010 (ČSN EN 14625) Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovni ovzdusi (imise) Stanoveni O3 automatickymi ultrafialovymi fotometrickymi analyzatory automatickymi ultrafialovymi fotometrickymi analyzatory T 22 AA-010 (CSN EN 14625)","search_en":"Ambient air (immissions) Determination of O3 by automatic ultraviolet photometric analysers automatic ultraviolet photometric analysers T 22 AA-010 (ČSN EN 14625)","search_zh":"环境空气（环境浓度） 自动紫外光度分析仪测定O3 自动紫外光度分析仪 T 22 AA-010 (ČSN EN 14625)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2f3fbf4483f8486cbb43e424","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"18","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie","methodology_en":"Determination of O3 by automatic ultraviolet photometric analysers","methodology_zh":"自动紫外光度分析仪测定O3","methodology_cs":"Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fotometryczne w nadfiolecie","technique_en":"automatic ultraviolet photometric analysers","technique_zh":"自动紫外光度分析仪","technique_cs":"automatickými ultrafialovými fotometrickými analyzátory","techniques":["automatyczne analizatory fotometryczne w nadfiolecie"],"techniques_en":["automatic ultraviolet photometric analysers"],"techniques_zh":["自动紫外光度分析仪"],"techniques_cs":["automatickými ultrafialovými fotometrickými analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie\nautomatyczne analizatory fotometryczne w nadfiolecie","reference":"T 22 AA-010 (ČSN EN 14625)","norm_bases":["T 22 AA-010","ČSN EN 14625"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovní ovzduší (imise) Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory automatickými ultrafialovými fotometrickými analyzátory T 22 AA-010 (ČSN EN 14625) Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovni ovzdusi (imise) Stanoveni O3 automatickymi ultrafialovymi fotometrickymi analyzatory automatickymi ultrafialovymi fotometrickymi analyzatory T 22 AA-010 (CSN EN 14625)","search_en":"Ambient air (immissions) Determination of O3 by automatic ultraviolet photometric analysers automatic ultraviolet photometric analysers T 22 AA-010 (ČSN EN 14625)","search_zh":"环境空气（环境浓度） 自动紫外光度分析仪测定O3 自动紫外光度分析仪 T 22 AA-010 (ČSN EN 14625)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"422e4a9120eba2db6c399ffa","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"18","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie","methodology_en":"Determination of O3 by automatic ultraviolet photometric analysers","methodology_zh":"自动紫外光度分析仪测定O3","methodology_cs":"Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fotometryczne w nadfiolecie","technique_en":"automatic ultraviolet photometric analysers","technique_zh":"自动紫外光度分析仪","technique_cs":"automatickými ultrafialovými fotometrickými analyzátory","techniques":["automatyczne analizatory fotometryczne w nadfiolecie"],"techniques_en":["automatic ultraviolet photometric analysers"],"techniques_zh":["自动紫外光度分析仪"],"techniques_cs":["automatickými ultrafialovými fotometrickými analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie\nautomatyczne analizatory fotometryczne w nadfiolecie","reference":"T 22 AA-010 (ČSN EN 14625)","norm_bases":["T 22 AA-010","ČSN EN 14625"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovní ovzduší (imise) Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory automatickými ultrafialovými fotometrickými analyzátory T 22 AA-010 (ČSN EN 14625) Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovni ovzdusi (imise) Stanoveni O3 automatickymi ultrafialovymi fotometrickymi analyzatory automatickymi ultrafialovymi fotometrickymi analyzatory T 22 AA-010 (CSN EN 14625)","search_en":"Ambient air (immissions) Determination of O3 by automatic ultraviolet photometric analysers automatic ultraviolet photometric analysers T 22 AA-010 (ČSN EN 14625)","search_zh":"环境空气（环境浓度） 自动紫外光度分析仪测定O3 自动紫外光度分析仪 T 22 AA-010 (ČSN EN 14625)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"853b42ff3b8f72c71577902c","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"18","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie","methodology_en":"Determination of O3 by automatic ultraviolet photometric analysers","methodology_zh":"自动紫外光度分析仪测定O3","methodology_cs":"Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"automatyczne analizatory fotometryczne w nadfiolecie","technique_en":"automatic ultraviolet photometric analysers","technique_zh":"自动紫外光度分析仪","technique_cs":"automatickými ultrafialovými fotometrickými analyzátory","techniques":["automatyczne analizatory fotometryczne w nadfiolecie"],"techniques_en":["automatic ultraviolet photometric analysers"],"techniques_zh":["自动紫外光度分析仪"],"techniques_cs":["automatickými ultrafialovými fotometrickými analyzátory"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie\nautomatyczne analizatory fotometryczne w nadfiolecie","reference":"T 22 AA-010 (ČSN EN 14625)","norm_bases":["T 22 AA-010","ČSN EN 14625"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovní ovzduší (imise) Stanovení O3 automatickými ultrafialovými fotometrickými analyzátory automatickými ultrafialovými fotometrickými analyzátory T 22 AA-010 (ČSN EN 14625) Powietrze atmosferyczne (imisja) Oznaczanie O3 automatycznymi analizatorami fotometrycznymi w nadfiolecie automatyczne analizatory fotometryczne w nadfiolecie Venkovni ovzdusi (imise) Stanoveni O3 automatickymi ultrafialovymi fotometrickymi analyzatory automatickymi ultrafialovymi fotometrickymi analyzatory T 22 AA-010 (CSN EN 14625)","search_en":"Ambient air (immissions) Determination of O3 by automatic ultraviolet photometric analysers automatic ultraviolet photometric analysers T 22 AA-010 (ČSN EN 14625)","search_zh":"环境空气（环境浓度） 自动紫外光度分析仪测定O3 自动紫外光度分析仪 T 22 AA-010 (ČSN EN 14625)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5dee9a0a951e9b067ce2fb81","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"1","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler","methodology_zh":"自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃","methodology_cs":"Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","reference":"T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","norm_bases":["T 21 AA-022","ČSN EN 15549","ČSN P CEN/TS 16645","ČSN EN 12341","ISO 12884"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierscieniowych weglowodorow aromatycznych automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na filtr/PUF pro stanoveni polycyklickych aromatickych uhlovodiku automatickym vzorkovacem T 21 AA-022 (CSN EN 15549; CSN P CEN/TS 16645; CSN EN 12341; ISO 12884)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃 T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f4ce558419b9470e5c19cdbd","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"1","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler","methodology_zh":"自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃","methodology_cs":"Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","reference":"T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","norm_bases":["T 21 AA-022","ČSN EN 15549","ČSN P CEN/TS 16645","ČSN EN 12341","ISO 12884"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierscieniowych weglowodorow aromatycznych automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na filtr/PUF pro stanoveni polycyklickych aromatickych uhlovodiku automatickym vzorkovacem T 21 AA-022 (CSN EN 15549; CSN P CEN/TS 16645; CSN EN 12341; ISO 12884)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃 T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7841f932a1a174ba8c73eadf","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"1","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler","methodology_zh":"自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃","methodology_cs":"Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","reference":"T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","norm_bases":["T 21 AA-022","ČSN EN 15549","ČSN P CEN/TS 16645","ČSN EN 12341","ISO 12884"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierscieniowych weglowodorow aromatycznych automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na filtr/PUF pro stanoveni polycyklickych aromatickych uhlovodiku automatickym vzorkovacem T 21 AA-022 (CSN EN 15549; CSN P CEN/TS 16645; CSN EN 12341; ISO 12884)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃 T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6d43d350690179da1a619794","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"1","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler","methodology_zh":"自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃","methodology_cs":"Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","reference":"T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","norm_bases":["T 21 AA-022","ČSN EN 15549","ČSN P CEN/TS 16645","ČSN EN 12341","ISO 12884"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierscieniowych weglowodorow aromatycznych automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na filtr/PUF pro stanoveni polycyklickych aromatickych uhlovodiku automatickym vzorkovacem T 21 AA-022 (CSN EN 15549; CSN P CEN/TS 16645; CSN EN 12341; ISO 12884)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃 T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"60e97493f66d4f29dda844b7","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"1","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler","methodology_zh":"自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃","methodology_cs":"Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","reference":"T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","norm_bases":["T 21 AA-022","ČSN EN 15549","ČSN P CEN/TS 16645","ČSN EN 12341","ISO 12884"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierscieniowych weglowodorow aromatycznych automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na filtr/PUF pro stanoveni polycyklickych aromatickych uhlovodiku automatickym vzorkovacem T 21 AA-022 (CSN EN 15549; CSN P CEN/TS 16645; CSN EN 12341; ISO 12884)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃 T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"800640680bc214f39c8f7660","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"1","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler","methodology_zh":"自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃","methodology_cs":"Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem","reference":"T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","norm_bases":["T 21 AA-022","ČSN EN 15549","ČSN P CEN/TS 16645","ČSN EN 12341","ISO 12884"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierścieniowych węglowodorów aromatycznych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na filtr/PUF pro stanovení polycyklických aromatických uhlovodíků automatickým vzorkovačem T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr/PUF do oznaczania wielopierscieniowych weglowodorow aromatycznych automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na filtr/PUF pro stanoveni polycyklickych aromatickych uhlovodiku automatickym vzorkovacem T 21 AA-022 (CSN EN 15549; CSN P CEN/TS 16645; CSN EN 12341; ISO 12884)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter/PUF for determination of polycyclic aromatic hydrocarbons with an automatic sampler T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜/PUF采集环境空气用于测定多环芳烃 T 21 AA-022 (ČSN EN 15549; ČSN P CEN/TS 16645; ČSN EN 12341; ISO 12884)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4024b0b537fb4e2c3a259d4e","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"2","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego do kanistra do oznaczania lotnych związków organicznych (VOC) (pobór ręczny)","methodology_en":"Sampling of ambient air into a canister for determination of volatile organic compounds (VOC) (manual sampling)","methodology_zh":"罐采样法采集环境空气用于测定挥发性有机物（VOC）（手动采样）","methodology_cs":"Odběr venkovního ovzduší do kanystru pro stanovení těkavých organických látek (VOC) (manuální odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego do kanistra do oznaczania lotnych związków organicznych (VOC) (pobór ręczny)","reference":"T 21 AA-023 (EPA Methods: Method TO14)","norm_bases":["T 21 AA-023","EPA Methods: Method TO14"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego do kanistra do oznaczania lotnych związków organicznych (VOC) (pobór ręczny) Venkovní ovzduší (imise) Odběr venkovního ovzduší do kanystru pro stanovení těkavých organických látek (VOC) (manuální odběr) T 21 AA-023 (EPA Methods: Method TO14) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego do kanistra do oznaczania lotnych zwiazkow organicznych (VOC) (pobor reczny) Venkovni ovzdusi (imise) Odber venkovniho ovzdusi do kanystru pro stanoveni tekavych organickych latek (VOC) (manualni odber) T 21 AA-023 (EPA Methods: Method TO14)","search_en":"Ambient air (immissions) Sampling of ambient air into a canister for determination of volatile organic compounds (VOC) (manual sampling) T 21 AA-023 (EPA Methods: Method TO14)","search_zh":"环境空气（环境浓度） 罐采样法采集环境空气用于测定挥发性有机物（VOC）（手动采样） T 21 AA-023 (EPA Methods: Method TO14)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4d34f7a3ecec90035ba1a531","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"3","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonów azotanowych, siarczanowych i amonowych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filters for determination of gaseous nitric acid, gaseous ammonia and nitrate, sulphate and ammonium ions with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气态硝酸、气态氨及硝酸根、硫酸根和铵离子","methodology_cs":"Odběr vzorků venkovního ovzduší na filtry pro stanovení plynné kyseliny dusičné, plynného amoniaku a dusičnanových, síranových a amonných iontů automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonów azotanowych, siarczanowych i amonowych automatycznym próbnikiem","reference":"T 21 AA-024 (EMEP manual for sampling and chemical analysis)","norm_bases":["T 21 AA-024","EMEP manual for sampling and chemical analysis"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonów azotanowych, siarczanowych i amonowych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtry pro stanovení plynné kyseliny dusičné, plynného amoniaku a dusičnanových, síranových a amonných iontů automatickým vzorkovačem T 21 AA-024 (EMEP manual for sampling and chemical analysis) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonow azotanowych, siarczanowych i amonowych automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtry pro stanoveni plynne kyseliny dusicne, plynneho amoniaku a dusicnanovych, siranovych a amonnych iontu automatickym vzorkovacem T 21 AA-024 (EMEP manual for sampling and chemical analysis)","search_en":"Ambient air (immissions) Sampling of ambient air onto filters for determination of gaseous nitric acid, gaseous ammonia and nitrate, sulphate and ammonium ions with an automatic sampler T 21 AA-024 (EMEP manual for sampling and chemical analysis)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气态硝酸、气态氨及硝酸根、硫酸根和铵离子 T 21 AA-024 (EMEP manual for sampling and chemical analysis)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b836f89598a7d5f2100f2b32","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"3","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonów azotanowych, siarczanowych i amonowych automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filters for determination of gaseous nitric acid, gaseous ammonia and nitrate, sulphate and ammonium ions with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气态硝酸、气态氨及硝酸根、硫酸根和铵离子","methodology_cs":"Odběr vzorků venkovního ovzduší na filtry pro stanovení plynné kyseliny dusičné, plynného amoniaku a dusičnanových, síranových a amonných iontů automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonów azotanowych, siarczanowych i amonowych automatycznym próbnikiem","reference":"T 21 AA-024 (EMEP manual for sampling and chemical analysis)","norm_bases":["T 21 AA-024","EMEP manual for sampling and chemical analysis"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonów azotanowych, siarczanowych i amonowych automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtry pro stanovení plynné kyseliny dusičné, plynného amoniaku a dusičnanových, síranových a amonných iontů automatickým vzorkovačem T 21 AA-024 (EMEP manual for sampling and chemical analysis) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtry do oznaczania gazowego kwasu azotowego, gazowego amoniaku oraz jonow azotanowych, siarczanowych i amonowych automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtry pro stanoveni plynne kyseliny dusicne, plynneho amoniaku a dusicnanovych, siranovych a amonnych iontu automatickym vzorkovacem T 21 AA-024 (EMEP manual for sampling and chemical analysis)","search_en":"Ambient air (immissions) Sampling of ambient air onto filters for determination of gaseous nitric acid, gaseous ammonia and nitrate, sulphate and ammonium ions with an automatic sampler T 21 AA-024 (EMEP manual for sampling and chemical analysis)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气态硝酸、气态氨及硝酸根、硫酸根和铵离子 T 21 AA-024 (EMEP manual for sampling and chemical analysis)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d091cbcbce02beb6c45dd7e4","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"4","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling)","methodology_zh":"固体吸附剂采集环境空气用于测定苯（被动采样）","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","reference":"T 21 AA-026 (ČSN EN ISO 16017-2)","norm_bases":["T 21 AA-026","ČSN EN ISO 16017-2"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny) Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr) T 21 AA-026 (ČSN EN ISO 16017-2) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu (pobor pasywny) Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu (pasivni odber) T 21 AA-026 (CSN EN ISO 16017-2)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) T 21 AA-026 (ČSN EN ISO 16017-2)","search_zh":"环境空气（环境浓度） 固体吸附剂采集环境空气用于测定苯（被动采样） T 21 AA-026 (ČSN EN ISO 16017-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"21ccee7d2cab2d6177fef8f6","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"4","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling)","methodology_zh":"固体吸附剂采集环境空气用于测定苯（被动采样）","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","reference":"T 21 AA-026 (ČSN EN ISO 16017-2)","norm_bases":["T 21 AA-026","ČSN EN ISO 16017-2"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny) Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr) T 21 AA-026 (ČSN EN ISO 16017-2) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu (pobor pasywny) Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu (pasivni odber) T 21 AA-026 (CSN EN ISO 16017-2)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) T 21 AA-026 (ČSN EN ISO 16017-2)","search_zh":"环境空气（环境浓度） 固体吸附剂采集环境空气用于测定苯（被动采样） T 21 AA-026 (ČSN EN ISO 16017-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50caac45b3679a1efeca3dd2","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"4","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling)","methodology_zh":"固体吸附剂采集环境空气用于测定苯（被动采样）","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","reference":"T 21 AA-026 (ČSN EN ISO 16017-2)","norm_bases":["T 21 AA-026","ČSN EN ISO 16017-2"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny) Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr) T 21 AA-026 (ČSN EN ISO 16017-2) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu (pobor pasywny) Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu (pasivni odber) T 21 AA-026 (CSN EN ISO 16017-2)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) T 21 AA-026 (ČSN EN ISO 16017-2)","search_zh":"环境空气（环境浓度） 固体吸附剂采集环境空气用于测定苯（被动采样） T 21 AA-026 (ČSN EN ISO 16017-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"97a08b525958d7b9436c2d9f","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"4","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling)","methodology_zh":"固体吸附剂采集环境空气用于测定苯（被动采样）","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","reference":"T 21 AA-026 (ČSN EN ISO 16017-2)","norm_bases":["T 21 AA-026","ČSN EN ISO 16017-2"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny) Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr) T 21 AA-026 (ČSN EN ISO 16017-2) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu (pobor pasywny) Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu (pasivni odber) T 21 AA-026 (CSN EN ISO 16017-2)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) T 21 AA-026 (ČSN EN ISO 16017-2)","search_zh":"环境空气（环境浓度） 固体吸附剂采集环境空气用于测定苯（被动采样） T 21 AA-026 (ČSN EN ISO 16017-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ecd9ca549a6bc0e0b167f61","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"4","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling)","methodology_zh":"固体吸附剂采集环境空气用于测定苯（被动采样）","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","reference":"T 21 AA-026 (ČSN EN ISO 16017-2)","norm_bases":["T 21 AA-026","ČSN EN ISO 16017-2"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny) Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr) T 21 AA-026 (ČSN EN ISO 16017-2) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu (pobor pasywny) Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu (pasivni odber) T 21 AA-026 (CSN EN ISO 16017-2)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) T 21 AA-026 (ČSN EN ISO 16017-2)","search_zh":"环境空气（环境浓度） 固体吸附剂采集环境空气用于测定苯（被动采样） T 21 AA-026 (ČSN EN ISO 16017-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"701a5c97ed9f50767316785a","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"4","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling)","methodology_zh":"固体吸附剂采集环境空气用于测定苯（被动采样）","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny)","reference":"T 21 AA-026 (ČSN EN ISO 16017-2)","norm_bases":["T 21 AA-026","ČSN EN ISO 16017-2"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu (pobór pasywny) Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu (pasivní odběr) T 21 AA-026 (ČSN EN ISO 16017-2) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu (pobor pasywny) Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu (pasivni odber) T 21 AA-026 (CSN EN ISO 16017-2)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene (passive sampling) T 21 AA-026 (ČSN EN ISO 16017-2)","search_zh":"环境空气（环境浓度） 固体吸附剂采集环境空气用于测定苯（被动采样） T 21 AA-026 (ČSN EN ISO 16017-2)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"18574c4a6a88793fefe4562b","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"5","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb","methodology_cs":"Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","reference":"T 21 AA-027 (ČSN EN 12341)","norm_bases":["T 21 AA-027","ČSN EN 12341"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem T 21 AA-027 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr do oznaczania czastek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtr pro stanoveni aerosolovych castic (PM10 a PM2,5), Ni, As, Cd a Pb automatickym vzorkovacem T 21 AA-027 (CSN EN 12341)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler T 21 AA-027 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb T 21 AA-027 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e7d8e9a47dfd907652b642c6","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"5","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb","methodology_cs":"Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","reference":"T 21 AA-027 (ČSN EN 12341)","norm_bases":["T 21 AA-027","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem T 21 AA-027 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr do oznaczania czastek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtr pro stanoveni aerosolovych castic (PM10 a PM2,5), Ni, As, Cd a Pb automatickym vzorkovacem T 21 AA-027 (CSN EN 12341)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler T 21 AA-027 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb T 21 AA-027 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2eeb7eb902dada7b8ddb4a8e","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"5","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb","methodology_cs":"Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","reference":"T 21 AA-027 (ČSN EN 12341)","norm_bases":["T 21 AA-027","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem T 21 AA-027 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr do oznaczania czastek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtr pro stanoveni aerosolovych castic (PM10 a PM2,5), Ni, As, Cd a Pb automatickym vzorkovacem T 21 AA-027 (CSN EN 12341)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler T 21 AA-027 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb T 21 AA-027 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"40980ca2141db0329fbd2763","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"5","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb","methodology_cs":"Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","reference":"T 21 AA-027 (ČSN EN 12341)","norm_bases":["T 21 AA-027","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem T 21 AA-027 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr do oznaczania czastek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtr pro stanoveni aerosolovych castic (PM10 a PM2,5), Ni, As, Cd a Pb automatickym vzorkovacem T 21 AA-027 (CSN EN 12341)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler T 21 AA-027 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb T 21 AA-027 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b52770a94a988e37dce9328b","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"5","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb","methodology_cs":"Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","reference":"T 21 AA-027 (ČSN EN 12341)","norm_bases":["T 21 AA-027","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem T 21 AA-027 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr do oznaczania czastek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtr pro stanoveni aerosolovych castic (PM10 a PM2,5), Ni, As, Cd a Pb automatickym vzorkovacem T 21 AA-027 (CSN EN 12341)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler T 21 AA-027 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb T 21 AA-027 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f4ff33f1d4835c4f94827349","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"5","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler","methodology_zh":"自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb","methodology_cs":"Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem","reference":"T 21 AA-027 (ČSN EN 12341)","norm_bases":["T 21 AA-027","ČSN EN 12341"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na filtr do oznaczania cząstek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym próbnikiem Venkovní ovzduší (imise) Odběr vzorků venkovního ovzduší na filtr pro stanovení aerosolových částic (PM10 a PM2,5), Ni, As, Cd a Pb automatickým vzorkovačem T 21 AA-027 (ČSN EN 12341) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na filtr do oznaczania czastek aerozolu (PM10 i PM2,5), Ni, As, Cd i Pb automatycznym probnikiem Venkovni ovzdusi (imise) Odber vzorku venkovniho ovzdusi na filtr pro stanoveni aerosolovych castic (PM10 a PM2,5), Ni, As, Cd a Pb automatickym vzorkovacem T 21 AA-027 (CSN EN 12341)","search_en":"Ambient air (immissions) Sampling of ambient air onto filter for determination of aerosol particles (PM10 and PM2.5), Ni, As, Cd and Pb with an automatic sampler T 21 AA-027 (ČSN EN 12341)","search_zh":"环境空气（环境浓度） 自动采样器以滤膜采集环境空气用于测定气溶胶颗粒（PM10和PM2.5）、Ni、As、Cd和Pb T 21 AA-027 (ČSN EN 12341)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75983214194e7e2e391218ff","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"6","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler","methodology_zh":"自动采样器以固体吸附剂采集环境空气用于测定苯","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","reference":"T 21 AA-028 (ČSN EN ISO 16017-1)","norm_bases":["T 21 AA-028","ČSN EN ISO 16017-1"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem T 21 AA-028 (ČSN EN ISO 16017-1) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu automatickym vzorkovacem T 21 AA-028 (CSN EN ISO 16017-1)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler T 21 AA-028 (ČSN EN ISO 16017-1)","search_zh":"环境空气（环境浓度） 自动采样器以固体吸附剂采集环境空气用于测定苯 T 21 AA-028 (ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8c82f72211962567f8236117","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"6","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler","methodology_zh":"自动采样器以固体吸附剂采集环境空气用于测定苯","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","reference":"T 21 AA-028 (ČSN EN ISO 16017-1)","norm_bases":["T 21 AA-028","ČSN EN ISO 16017-1"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem T 21 AA-028 (ČSN EN ISO 16017-1) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu automatickym vzorkovacem T 21 AA-028 (CSN EN ISO 16017-1)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler T 21 AA-028 (ČSN EN ISO 16017-1)","search_zh":"环境空气（环境浓度） 自动采样器以固体吸附剂采集环境空气用于测定苯 T 21 AA-028 (ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb221c50622b39e008b4162d","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"6","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler","methodology_zh":"自动采样器以固体吸附剂采集环境空气用于测定苯","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","reference":"T 21 AA-028 (ČSN EN ISO 16017-1)","norm_bases":["T 21 AA-028","ČSN EN ISO 16017-1"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem T 21 AA-028 (ČSN EN ISO 16017-1) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu automatickym vzorkovacem T 21 AA-028 (CSN EN ISO 16017-1)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler T 21 AA-028 (ČSN EN ISO 16017-1)","search_zh":"环境空气（环境浓度） 自动采样器以固体吸附剂采集环境空气用于测定苯 T 21 AA-028 (ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"76c2c88aa864dd2ec7ce82d7","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"6","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler","methodology_zh":"自动采样器以固体吸附剂采集环境空气用于测定苯","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","reference":"T 21 AA-028 (ČSN EN ISO 16017-1)","norm_bases":["T 21 AA-028","ČSN EN ISO 16017-1"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem T 21 AA-028 (ČSN EN ISO 16017-1) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu automatickym vzorkovacem T 21 AA-028 (CSN EN ISO 16017-1)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler T 21 AA-028 (ČSN EN ISO 16017-1)","search_zh":"环境空气（环境浓度） 自动采样器以固体吸附剂采集环境空气用于测定苯 T 21 AA-028 (ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5bf07dcfe2f0cc7b21807c1a","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"6","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler","methodology_zh":"自动采样器以固体吸附剂采集环境空气用于测定苯","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","reference":"T 21 AA-028 (ČSN EN ISO 16017-1)","norm_bases":["T 21 AA-028","ČSN EN ISO 16017-1"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem T 21 AA-028 (ČSN EN ISO 16017-1) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu automatickym vzorkovacem T 21 AA-028 (CSN EN ISO 16017-1)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler T 21 AA-028 (ČSN EN ISO 16017-1)","search_zh":"环境空气（环境浓度） 自动采样器以固体吸附剂采集环境空气用于测定苯 T 21 AA-028 (ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7763005d1a2677a667032be1","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"6","test_object":"Powietrze atmosferyczne (imisja)","test_object_en":"Ambient air (immissions)","test_object_zh":"环境空气（环境浓度）","test_object_cs":"Venkovní ovzduší (imise)","methodology":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","methodology_en":"Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler","methodology_zh":"自动采样器以固体吸附剂采集环境空气用于测定苯","methodology_cs":"Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem","reference":"T 21 AA-028 (ČSN EN ISO 16017-1)","norm_bases":["T 21 AA-028","ČSN EN ISO 16017-1"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Powietrze atmosferyczne (imisja) Pobieranie próbek powietrza atmosferycznego na sorbent stały do oznaczania benzenu automatycznym próbnikiem Venkovní ovzduší (imise) Odběr venkovního ovzduší na pevný sorbent pro stanovení benzenu automatickým vzorkovačem T 21 AA-028 (ČSN EN ISO 16017-1) Powietrze atmosferyczne (imisja) Pobieranie probek powietrza atmosferycznego na sorbent staly do oznaczania benzenu automatycznym probnikiem Venkovni ovzdusi (imise) Odber venkovniho ovzdusi na pevny sorbent pro stanoveni benzenu automatickym vzorkovacem T 21 AA-028 (CSN EN ISO 16017-1)","search_en":"Ambient air (immissions) Sampling of ambient air onto solid sorbent for determination of benzene with an automatic sampler T 21 AA-028 (ČSN EN ISO 16017-1)","search_zh":"环境空气（环境浓度） 自动采样器以固体吸附剂采集环境空气用于测定苯 T 21 AA-028 (ČSN EN ISO 16017-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a8e6cf76362609e3b5ef111","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"7","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","methodology_en":"Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector)","methodology_zh":"自动采样器（降水收集器）采集“仅湿沉降”型降水样品","methodology_cs":"Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","reference":"T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","norm_bases":["T 21 AA-030","EMEP manual for sampling and chemical analysis","ČSN EN 15841"],"lab_section":"Monitoring imisji, CLI – ČHMÚ Praga","lab_section_en":"Immission monitoring, CLI – ČHMÚ Prague","lab_section_zh":"环境空气质量监测，CLI – ČHMÚ布拉格","lab_section_cs":"Imisní monitoring, CLI – ČHMÚ Praha","lab_address":"Generála Šišky 942, Libuš, 143 00 Praha 4","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów) Srážková voda Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) Woda opadowa Pobieranie probek wod opadowych typu „wet-only” automatycznym probnikiem (kolektor opadow) Srazkova voda Odber srazkovych vod typu ”wet-only“ automatickym vzorkovacem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; CSN EN 15841)","search_en":"Precipitation water Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","search_zh":"降水 自动采样器（降水收集器）采集“仅湿沉降”型降水样品 T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b50f63f2cccec0a40bac4420","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"7","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","methodology_en":"Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector)","methodology_zh":"自动采样器（降水收集器）采集“仅湿沉降”型降水样品","methodology_cs":"Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","reference":"T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","norm_bases":["T 21 AA-030","EMEP manual for sampling and chemical analysis","ČSN EN 15841"],"lab_section":"Monitoring imisji, P – ČHMÚ Ústí nad Labem","lab_section_en":"Immission monitoring, P – ČHMÚ Ústí nad Labem","lab_section_zh":"环境空气质量监测，P – ČHMÚ拉贝河畔乌斯季","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ústí nad Labem","lab_address":"Kočkovská 2699/18, 400 11 Ústí nad Labem","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów) Srážková voda Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) Woda opadowa Pobieranie probek wod opadowych typu „wet-only” automatycznym probnikiem (kolektor opadow) Srazkova voda Odber srazkovych vod typu ”wet-only“ automatickym vzorkovacem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; CSN EN 15841)","search_en":"Precipitation water Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","search_zh":"降水 自动采样器（降水收集器）采集“仅湿沉降”型降水样品 T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"17cbfe6c5acc7b54e2b0861c","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"7","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","methodology_en":"Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector)","methodology_zh":"自动采样器（降水收集器）采集“仅湿沉降”型降水样品","methodology_cs":"Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","reference":"T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","norm_bases":["T 21 AA-030","EMEP manual for sampling and chemical analysis","ČSN EN 15841"],"lab_section":"Monitoring imisji, P – ČHMÚ Ostrawa","lab_section_en":"Immission monitoring, P – ČHMÚ Ostrava","lab_section_zh":"环境空气质量监测，P – ČHMÚ俄斯特拉发","lab_section_cs":"Imisní monitoring, P – ČHMÚ Ostrava","lab_address":"K Myslivně 2182/3, 708 00 Ostrava","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów) Srážková voda Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) Woda opadowa Pobieranie probek wod opadowych typu „wet-only” automatycznym probnikiem (kolektor opadow) Srazkova voda Odber srazkovych vod typu ”wet-only“ automatickym vzorkovacem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; CSN EN 15841)","search_en":"Precipitation water Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","search_zh":"降水 自动采样器（降水收集器）采集“仅湿沉降”型降水样品 T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":80,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c336b057e317e3599b7de0a1","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"7","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","methodology_en":"Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector)","methodology_zh":"自动采样器（降水收集器）采集“仅湿沉降”型降水样品","methodology_cs":"Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","reference":"T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","norm_bases":["T 21 AA-030","EMEP manual for sampling and chemical analysis","ČSN EN 15841"],"lab_section":"Monitoring imisji, P – ČHMÚ Brno","lab_section_en":"Immission monitoring, P – ČHMÚ Brno","lab_section_zh":"环境空气质量监测，P – ČHMÚ布尔诺","lab_section_cs":"Imisní monitoring, P – ČHMÚ Brno","lab_address":"Kroftova 2578/43, 616 67 Brno","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów) Srážková voda Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) Woda opadowa Pobieranie probek wod opadowych typu „wet-only” automatycznym probnikiem (kolektor opadow) Srazkova voda Odber srazkovych vod typu ”wet-only“ automatickym vzorkovacem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; CSN EN 15841)","search_en":"Precipitation water Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","search_zh":"降水 自动采样器（降水收集器）采集“仅湿沉降”型降水样品 T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":81,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"24ae7f789b00b486527a6e16","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"7","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","methodology_en":"Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector)","methodology_zh":"自动采样器（降水收集器）采集“仅湿沉降”型降水样品","methodology_cs":"Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","reference":"T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","norm_bases":["T 21 AA-030","EMEP manual for sampling and chemical analysis","ČSN EN 15841"],"lab_section":"Monitoring imisji, P – ČHMÚ Hradec Králové","lab_section_en":"Immission monitoring, P – ČHMÚ Hradec Králové","lab_section_zh":"环境空气质量监测，P – ČHMÚ赫拉德茨-克拉洛韦","lab_section_cs":"Imisní monitoring, P – ČHMÚ Hradec Králové","lab_address":"Dvorská 410/102, 503 11 Hradec Králové","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów) Srážková voda Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) Woda opadowa Pobieranie probek wod opadowych typu „wet-only” automatycznym probnikiem (kolektor opadow) Srazkova voda Odber srazkovych vod typu ”wet-only“ automatickym vzorkovacem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; CSN EN 15841)","search_en":"Precipitation water Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","search_zh":"降水 自动采样器（降水收集器）采集“仅湿沉降”型降水样品 T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":82,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5aaef5005a1bf64b0fc860d7","lab_id":"69ad52a4de79e566650fd40e","country":"CZ","accr_number":"1460","accr_body":"ČIA","row_label":"7","test_object":"Woda opadowa","test_object_en":"Precipitation water","test_object_zh":"降水","test_object_cs":"Srážková voda","methodology":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","methodology_en":"Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector)","methodology_zh":"自动采样器（降水收集器）采集“仅湿沉降”型降水样品","methodology_cs":"Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów)","reference":"T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","norm_bases":["T 21 AA-030","EMEP manual for sampling and chemical analysis","ČSN EN 15841"],"lab_section":"Monitoring imisji, P – ČHMÚ Pilzno","lab_section_en":"Immission monitoring, P – ČHMÚ Plzeň","lab_section_zh":"环境空气质量监测，P – ČHMÚ比尔森","lab_section_cs":"Imisní monitoring, P – ČHMÚ Plzeň","lab_address":"Mozartova 1237/41, 323 00 Plzeň","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda opadowa Pobieranie próbek wód opadowych typu „wet-only” automatycznym próbnikiem (kolektor opadów) Srážková voda Odběr srážkových vod typu ”wet-only“ automatickým vzorkovačem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841) Woda opadowa Pobieranie probek wod opadowych typu „wet-only” automatycznym probnikiem (kolektor opadow) Srazkova voda Odber srazkovych vod typu ”wet-only“ automatickym vzorkovacem (pluviokolektor) T 21 AA-030 (EMEP manual for sampling and chemical analysis; CSN EN 15841)","search_en":"Precipitation water Sampling of \"wet-only\" precipitation water with an automatic sampler (precipitation collector) T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","search_zh":"降水 自动采样器（降水收集器）采集“仅湿沉降”型降水样品 T 21 AA-030 (EMEP manual for sampling and chemical analysis; ČSN EN 15841)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":83,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}