🇨🇿 Povodí Ohře, státní podnik PL
Water & wastewaterEnvironmentMicrobiology
Povodí Ohře, státní podnik is a laboratory accredited by ČIA under number 1459 (Teplice, Czech Republic). Its accreditation scope covers 120 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Sludge, suspended solids, sediment, earth, Water, waste water, Water, waste water, bathing water, mineral water, aqueous leachate, Water, waste water, bathing water, mineral water, aqueous leachate,….
At a glance
- Accreditation number: ČIA 1459
- Methods in scope: 120
- Types of test objects: 40
- City: Teplice, Czech Republic
- Valid until: 05-05-2028
- Accreditation number
- 1459
- Accreditation body
- ČIA
- Address
- Novosedlická 758/24, 415 01 Teplice
- City
- Teplice, Czech Republic
- Division
- Wydział Laboratoriów Gospodarki Wodnej
- Valid until
- 05-05-2028
What this laboratory tests (40)
- Sludge, suspended solids, sediment, earth — 11 methods
- Water, waste water — 10 methods
- Water, waste water, bathing water, mineral water, aqueous leachate — 6 methods
- Water, waste water, bathing water, mineral water, aqueous leachate, process water — 6 methods
- Surface water — 5 methods
- Water — 5 methods
- Water, bathing water — 5 methods
- Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water, process water — 4 methods
- Drinking water, groundwater, waste water, surface water, raw water, treated water, mineral water, process water — 4 methods
- Groundwater, waste water, surface water, raw water, treated water, bathing water — 4 methods
- Water, waste water, bathing water — 4 methods
- Water, waste water, bathing water, aqueous leachate — 4 methods
- Water, waste water, bathing water, aqueous leachate, process water — 4 methods
- Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water — 3 methods
- Surface water, bathing water — 3 methods
- and 25 more
Laboratory sections (2)
- 1. Teplice — 95 methods
- 2. Karlovy Vary — 25 methods
Laboratory locations
- 1. Teplice — Novosedlická 758/24
- 2. Karlowe Wary — Horova 12
Certificate information
- Certificate date
- 22.12.2025
Accreditation scope — test methods (120)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| 1. Teplice | |||||
| 1 | Water, waste water, bathing water | Determination of dissolved oxygen by iodometric titration Regulated area: Tests |
ZCH 01 (ČSN EN 25813) | ||
| 2 | Groundwater, waste water, surface water, raw water, treated water, bathing water | Determination of dissolved oxygen by electrochemistry with a membrane probe Regulated area: Tests |
ZCH 02 (ČSN EN ISO 5814) | ||
| 3 | Groundwater, waste water, surface water, raw water, treated water | Determination of biochemical oxygen demand after n days (BODn) by electrochemistry Regulated area: Tests |
ZCH 03 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 4 | Water, bathing water | Determination of chemical oxygen demand by permanganate (COD-Mn) by titration Regulated area: Tests |
ZCH 04 (ČSN EN ISO 8467) | ||
| 5 | Groundwater, waste water, surface water, raw water, aqueous leachate, process water | Determination of chemical oxygen demand by dichromate (COD-Cr) by spectrophotometry, MERCK kit Regulated area: Tests |
ZCH 06 (ČSN ISO 15705) | ||
| 6 | Water | Determination of absorbance by spectrophotometry Regulated area: Tests |
ZCH 07 (ČSN 75 7360) | ||
| 7 | Drinking water, groundwater, surface water, raw water, treated water, bathing water, process water | Determination of turbidity by turbidimetry Regulated area: Tests |
ZCH 08 (ČSN EN ISO 7027-1) | ||
| 8 | Water, waste water, mineral water, aqueous leachate, process water | Determination of dissolved solids by gravimetry Regulated area: Tests |
ZCH 09 (ČSN 75 7346) | ||
| 9 | Waste water, process water | Determination of dissolved inorganic salts (RAS) by gravimetry Regulated area: Tests |
ZCH 10 (ČSN 75 7347) | ||
| 10 | Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water, process water | Determination of suspended solids by gravimetry, method of filtration through glass fibre filters Regulated area: Tests |
ZCH 11 (ČSN EN 872) | ||
| 11 | Water, waste water, bathing water, aqueous leachate, process water | Determination of electrical conductivity Regulated area: Tests |
ZCH 12 (ČSN EN 27888) | ||
| 12 | Water, waste water, bathing water, aqueous leachate, process water | Determination of pH by potentiometry Regulated area: Tests |
ZCH 13 (ČSN ISO 10523) | ||
| 13 | Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water, process water | Determination of temperature Regulated area: Tests |
ZCH 14 (ČSN 75 7342) | ||
| 14 | Drinking water, groundwater, waste water, surface water, raw water, treated water, mineral water, process water | Determination of acid neutralising capacity KNK by titration, including calculation of the content of carbon dioxide forms from measured values Regulated area: Tests |
ZCH 15 (ČSN EN ISO 9963-1; ČSN 75 7373) | ||
| 15 | Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water | Determination of colour by spectrophotometry Regulated area: Tests |
ZCH 16 (ČSN EN ISO 7887) | ||
| 16 | Water, waste water, bathing water, aqueous leachate | Determination of anionic surfactants by spectrophotometry with methylene blue Regulated area: Tests |
ZCH 17 (ČSN EN 903) | ||
| 17 | Drinking water, groundwater, surface water, raw water, treated water | Determination of humic substances by spectrophotometry Regulated area: Tests |
ZCH 18 (ČSN 75 7536) | ||
| 18 | Water, waste water, bathing water, aqueous leachate | Determination of monohydric phenols by spectrophotometry with 4-aminoantipyrine after distillation Regulated area: Tests |
ZCH 19 (ČSN ISO 6439) | ||
| 19 | Water, waste water, bathing water, mineral water, aqueous leachate | Determination of fluorides with an ion-selective electrode Regulated area: Tests |
ZCH 20 (ČSN ISO 10359-1) | ||
| 20 | Water, waste water, bathing water, mineral water, aqueous leachate | Determination of nitrite nitrogen by spectrophotometry using continuous flow analysis (CFA), including calculation of nitrites from measured values Regulated area: Tests |
ZCH 21 (ČSN EN ISO 13395) | ||
| 21 | Water, waste water, bathing water, mineral water, aqueous leachate | Determination of nitrate nitrogen by spectrophotometry using continuous flow analysis (CFA), including calculation of nitrates and inorganic nitrogen from measured values Regulated area: Tests |
ZCH 22 (ČSN EN ISO 13395) | ||
| 22 | Water, waste water, bathing water, mineral water, aqueous leachate | Determination of ammoniacal nitrogen by spectrophotometry using continuous flow analysis (CFA), including calculation of ammonium ions and ammonia from measured values Regulated area: Tests |
ZCH 23 (ČSN EN ISO 11732) | ||
| 23 | Water, waste water, bathing water, mineral water, aqueous leachate, process water | Determination of chlorides by spectrophotometry using continuous flow analysis (CFA) Regulated area: Tests |
ZCH 24 (ČSN EN ISO 15682) | ||
| 24 | Waste water, surface water | Determination of CrVI by spectrophotometry with 1,5-diphenylcarbazide Regulated area: Tests |
ZCH 30 (ČSN ISO 11083) | ||
| 25 | Surface water, bathing water | Determination of chlorophyll a concentration by spectrophotometry Regulated area: Tests |
ZCH 31 (ČSN ISO 10260) | ||
| 26 | Drinking water, groundwater, waste water, surface water, raw water, treated water, mineral water, process water | Determination of base neutralising capacity ZNK by titration Regulated area: Tests |
ZCH 32 (ČSN 75 7372) | ||
| 27 | Water, waste water, bathing water, mineral water, aqueous leachate, process water | Determination of phosphate phosphorus by spectrophotometry using continuous flow analysis (CFA), including calculation of phosphates from measured values Regulated area: Tests |
ZCH 34 (ČSN EN ISO 15681-2) | ||
| 28 | Water, waste water, bathing water, mineral water, aqueous leachate, process water | Determination of total phosphorus by spectrophotometry using continuous flow analysis (CFA) Regulated area: Tests |
ZCH 35 (ČSN EN ISO 15681-2) | ||
| 29 | Water, waste water, bathing water, mineral water, aqueous leachate, process water | Determination of sulphates by spectrophotometry using continuous flow analysis (CFA) Regulated area: Tests |
ZCH 36 (ČSN ISO 22743) | ||
| 30 | Water, waste water, bathing water, mineral water, aqueous leachate | Determination of total cyanides by spectrophotometry using continuous flow analysis (CFA) Regulated area: Tests |
ZCH 37 (ČSN EN ISO 14403-2) | ||
| 31 | Water, waste water, bathing water, mineral water, aqueous leachate | Determination of free cyanides by spectrophotometry using continuous flow analysis (CFA) Regulated area: Tests |
ZCH 38 (ČSN EN ISO 14403-2) | ||
| 32 | Drinking water, bottled water, raw water, treated water | Determination of turbidity by nephelometry Regulated area: Tests |
ZCH 39 (ČSN EN ISO 7027-1) | ||
| 33 | Groundwater, waste water, surface water, raw water, treated water, bathing water | Determination of dissolved oxygen by the optical sensor method Regulated area: Tests |
ZCH 40 (ČSN ISO 17289) | ||
| 34 | Sludge, suspended solids, sediment, earth | Determination of total mercury with a dedicated AMA 254 atomic spectrophotometer Regulated area: Tests |
SAA 01 (ČSN 75 7440) | ||
| 35 | Water, waste water, bathing water, aqueous leachate | Determination of total mercury with a dedicated AMA 254 atomic spectrophotometer Regulated area: Tests |
SAA 02 (ČSN 75 7440) | ||
| 36 | Fish muscle tissue | Determination of total mercury with a dedicated AMA 254 atomic spectrophotometer Regulated area: Tests |
SAA 03 (ČSN 75 7440) | ||
| 37 | Water, waste water, bathing water, aqueous leachate | Determination of mercury by atomic fluorescence spectrometry Regulated area: Tests |
SAA 04 (ČSN EN ISO 17852) | ||
| 38 | Water, waste water, bathing water, mineral water, aqueous leachate, process water | Determination of Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Pb, Se, Si, Sn, V and Zn by inductively coupled plasma atomic emission spectrometry (ICP AES), including calculation of SiO2, the sum Ca+Mg, the Ca:Mg ratio and hardness as CaCO3 from measured values Silver (Ag) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Lithium (Li) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Nickel (Ni) Phosphorus (P) Lead (Pb) Selenium (Se) Silicon (Si) Tin (Sn) Vanadium (V) Zinc (Zn) Regulated area: Tests |
SAA 07 (ČSN EN ISO 11885) | ||
| 39 | Sludge, suspended solids, sediment, earth | Determination of Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Mo, Ni, P, Pb, V, Zn by inductively coupled plasma atomic emission spectrometry (ICP AES) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Nickel (Ni) Phosphorus (P) Lead (Pb) Vanadium (V) Zinc (Zn) Regulated area: Tests |
SAA 08 (ČSN EN ISO 11885) | ||
| 40 | Water, waste water, bathing water, mineral water, aqueous leachate, process water | Determination of Ag, Al, As, B, Ba, Be, Ca, Cd, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Mo, Na, Ni, P, Pb, Sb, Se, Sn, Tl, U, V, Zn by inductively coupled plasma mass spectrometry (ICP-MS), including calculation of the sum Ca+Mg, the Ca:Mg ratio, hardness as CaCO3 and the isotope 40K from measured values Silver (Ag) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Lithium (Li) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Thallium (Tl) Uranium (U) Vanadium (V) Zinc (Zn) Regulated area: Tests |
SAA 09 (ČSN EN ISO 17294-2) | ||
| 41 | Sludge, waste, suspended solids, soil, sediment, earth | Determination of total dry matter by gravimetry Regulated area: Tests |
SAA 11 (ČSN EN 12880; ČSN ISO 11465) | ||
| 42 | Sludge, waste, suspended solids, soil, sediment, earth | Determination of loss on ignition by gravimetry Regulated area: Tests |
SAA 12 (ČSN EN 15935; ČSN EN 12880) | ||
| 43 | Sludge, sediment, earth | Determination of Al, As, Ba, Be, Cd, Co, Cr, Cu, Fe, K, Mn, Mo, Ni, P, Pb, Sb, Se, V, Zn by inductively coupled plasma mass spectrometry (ICP-MS) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Manganese (Mn) Molybdenum (Mo) Nickel (Ni) Phosphorus (P) Lead (Pb) Antimony (Sb) Selenium (Se) Vanadium (V) Zinc (Zn) Regulated area: Tests |
SAA 13 (ČSN EN ISO 17294-2) | ||
| 44 | Water, waste water | Determination of polycyclic aromatic hydrocarbons (PAH) after extraction by HPLC with fluorescence detection and calculation of PAH sums from measured values Regulated area: Tests |
SOA 01 (ČSN EN ISO 17993) | ||
| 45 | Sludge, suspended solids, sediment, earth | Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detection and calculation of PAH sums from measured values Regulated area: Tests |
SOA 02 (ČSN EN 17503) | ||
| 46 | Water, waste water | Determination of adsorbable organically bound halogens (AOX) by microcoulometric titration Regulated area: Tests |
SOA 03 (ČSN EN ISO 9562) | ||
| 47 | Sludge, suspended solids, sediment, earth | Determination of adsorbable organically bound halogens (AOX) by microcoulometric titration Regulated area: Tests |
SOA 04 (ČSN EN 16166) | ||
| 48 | Water, waste water, aqueous leachate | Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by thermal decomposition and catalytic oxidation Regulated area: Tests |
SOA 06 (ČSN EN 1484) | ||
| 49 | Sludge, suspended solids, sediment, earth | Determination of total organic carbon (TOC) with an analyser Regulated area: Tests |
SOA 07 (ČSN EN 13137:2018) | ||
| 50 | Water, waste water, aqueous leachate | Determination of bound nitrogen (TN) after oxidation to nitrogen oxides with a chemiluminescence detector, including calculation of organic nitrogen from measured values Regulated area: Tests |
SOA 08 (ČSN EN ISO 20236) | ||
| 51 | Water, waste water, bathing water | Determination of extractable and non-polar extractable substances after extraction by infrared spectrometry Regulated area: Tests |
SOA 09 (ČSN 75 7505:2004; ČSN 75 7506) | ||
| 52 | Water, waste water, aqueous leachate | Determination of C10 to C40 hydrocarbon content by GC/FID Regulated area: Tests |
SOA 10 (ČSN EN ISO 9377-2) | ||
| 53 | Sludge, suspended solids, sediment, earth | Determination of C10 to C40 hydrocarbon content by GC/FID Regulated area: Tests |
SOA 11 (ČSN EN 14039) | ||
| 54 | Water, waste water | Determination of complexing agents after esterification and extraction with GC/MS detection NTA (nitrilotriacetic acid) EDTA (ethylenediaminetetraacetic acid) 1,3-PDTA (1,3-propylenediaminetetraacetic acid) Regulated area: Tests |
SOA 12 (ČSN EN ISO 16588) | ||
| 55 | Waste water, surface water | Determination of bis(dichloropropyl) ethers after extraction into isooctane with detection (GC/ECD, GC/MS) and calculation of their sum from measured values Regulated area: Tests |
SOA 13 (ČSN EN ISO 6468) | ||
| 56 | Water, waste water | Determination of phenols, chlorinated phenols, naphthols and alkylphenols after derivatisation with acetic anhydride with GC/MS detection and calculation of their sums from measured values Regulated area: Tests |
SOA 14 (ČSN EN 12673) | ||
| 57 | Sludge, suspended solids, sediment, earth | Determination of chlorinated phenols (CP) and other selected organic substances after extraction with GC/MS detection and calculation of the sum of selected chlorinated phenols from measured values Regulated area: Tests |
SOA 15 (ČSN EN 12673; ČSN ISO 24293) | ||
| 58 | Water, waste water | Determination of chlorpyrifos, polybrominated diphenyl ethers and other selected organic substances after extraction with GC/MS detection and calculation of the sum of selected PBDEs from measured values Regulated area: Tests |
SOA 16 (ČSN EN 12918) | ||
| 59 | Sludge, suspended solids, sediment, earth | Determination of polybrominated diphenyl ethers and other selected organic substances after extraction with GC/MS detection Regulated area: Tests |
SOA 17 (ČSN EN 12918) | ||
| 60 | Water, waste water | Determination of organochlorine pesticides (OCP), polychlorinated biphenyls (PCB) and other selected organic substances after extraction by gas chromatography with mass detection (GC-MS/MS) and calculation of sums of selected analytes from measured values Regulated area: Tests |
SOA 18 (ČSN EN ISO 6468) | ||
| 61 | Sludge, suspended solids, sediment, earth | Determination of organochlorine pesticides (OCP), polychlorinated biphenyls (PCB) and other selected organic substances after extraction by gas chromatography with mass detection (GC-MS/MS) and calculation of sums of selected analytes from measured values Regulated area: Tests |
SOA 19 (ČSN EN ISO 6468) | ||
| 62 | Water, waste water | Determination of volatile organic compounds by the purge & trap technique and gas chromatography with GC/MS detection and calculation of their sums from measured values Regulated area: Tests |
SOA 21 (ČSN EN ISO 15680) | ||
| 63 | Sludge, suspended solids, sediment, earth | Determination of volatile organic compounds by purge & trap and GC/MS and calculation of their sum (BTEX) from measured values Regulated area: Tests |
SOA 22 (EPA Method 8260; EPA Method 5030; ČSN EN ISO 15680) | ||
| 64 | Water | Determination of selected analytes by LC-MS/MS and calculation of sums of pesticide substances from measured values Regulated area: Tests |
SOA 27 (ČSN EN 15637; ČSN EN ISO 21676; ISO 21675; EPA Method 1694; EPA Method 1633) | ||
| 65 | Sludge, suspended solids, sediment, earth | Determination of selected analytes by LC-MS/MS and calculation of sums of pesticide substances from measured values Regulated area: Tests |
SOA 28 (ČSN EN 15637; ČSN ISO 21676) | ||
| 66 | Water, bathing water | Determination of bioseston, phytoplankton, number of organisms and living organisms by microscopy Regulated area: Tests |
HB 01 (ČSN 75 7712; ČSN EN 15204; ČSN 75 7717) | ||
| 67 | Water, bathing water | Determination of abioseston by microscopy Regulated area: Tests |
HB 02 (ČSN 75 7713) | ||
| 68 | Surface water | Determination of phytobenthos by microscopy Regulated area: Tests |
HB 03 (ČSN 75 7715; ČSN EN 13946; ČSN EN 14407) | ||
| 69 | Surface water | Determination of macrozoobenthos by microscopy Regulated area: Tests |
HB 04 (ČSN 75 7714; ČSN EN ISO 10870; ČSN ISO 5667-12; ČSN 75 7701) | ||
| 70 | Surface water | Determination of zooplankton by microscopy Regulated area: Tests |
HB 05 (ČSN EN 15110) | ||
| 71 | Surface water | Determination of macrophytes by species identification Regulated area: Tests |
HB 06 (ČSN EN 14184) | ||
| 72 | Surface water | Determination of juvenile fish communities by species identification Regulated area: Tests |
HB 07 (ČSN EN 14011) | ||
| 73 | Molluscs | Determination of cercariae of avian schistosomes by microscopy Regulated area: Tests |
HB 08 (ČSN 75 7737) | ||
| 74 | Water, bathing water | Enumeration of culturable micro-organisms at 22 °C and 36 °C by inoculation in a nutrient agar culture medium Regulated area: Tests |
MB 02 (ČSN EN ISO 6222) | ||
| 75 | Surface water, raw water, bathing water | Enumeration of coliform bacteria by membrane filtration Regulated area: Tests |
MB 03 (ČSN 75 7837) | ||
| 76 | Groundwater, waste water, surface water, raw water, bathing water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
MB 04 (ČSN 75 7835) | ||
| 77 | Water, waste water, bathing water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
MB 05 (ČSN EN ISO 7899-2) | ||
| 78 | Drinking water, bottled water, treated water | Enumeration of coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
MB 06 (ČSN EN ISO 9308-1) | ||
| 79 | Drinking water, groundwater, surface water, raw water, bathing water | Enumeration of coliform bacteria and Escherichia coli by the Colilert 18/Quanti-Tray method Regulated area: Tests |
MB 07 (ČSN EN ISO 9308-2) | ||
| 80 | Water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
MB 08 (ČSN EN ISO 14189) | ||
| 81 | Surface water, bathing water | Determination of transparency with a test disc Regulated area: Tests |
VZ 09 (ČSN 75 7340; ČSN EN ISO 7027-2) | ||
| 82 | Drinking water, surface water, treated water, bathing water | Determination of free and total chlorine with a Hach kit and of combined chlorine by calculation from measured values Regulated area: Tests |
VZ 10 (Manuál firmy Hach– Lange) | ||
| 83 | Drinking water, bottled water, raw water, treated water | Indicative sensory determination of taste and odour Regulated area: Tests |
VZ 11 (ČSN 75 7340, ČSN EN 1622; Vyhláška č. 252/2004 Sb.) | ||
| 84 | Surface water, raw water, bathing water | Determination of pH, dissolved oxygen, conductivity and temperature with a multiparameter probe Regulated area: Tests |
VZ 12 (ČSN ISO 10523; ČSN EN 27888; ČSN ISO 17289; Manuál firmy Hydrolab HL 2017) | ||
| 85 | Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water | Determination of oxidation-reduction potential Regulated area: Tests |
VZ 13 (ČSN 75 7367) | ||
| 86 | Water, waste water | Determination of gross alpha volume activity by measuring a mixture of the water sample evaporation residue with a ZnS (Ag) scintillator Regulated area: Tests |
RA 01 (ČSN 75 7611) | ||
| 87 | Water, waste water | Determination of gross beta volume activity by measuring the ignition residue of the evaporation residue with a proportional detector Regulated area: Tests |
RA 03 (ČSN 75 7612) | ||
| 88 | Water, waste water | Determination of 226Ra volume activity by emanometry without pre-concentration Regulated area: Tests |
RA 04 (ČSN 75 7623) | ||
| 89 | Water | Determination of 222Rn volume activity by emanometry using a circulation circuit Regulated area: Tests |
RA 05 (ČSN 75 7624) | ||
| 90 | Raw and surface water | Sampling of surface water Regulated area: Sampling |
VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 91 | Waste water, process water (cooling water, filtered water, boiler water, feed water, condensate) | Sampling of waste water (manual sampling, sampling with an automatic sampler) Regulated area: Sampling |
VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; Vyhláška č. 328/2018 Sb.) | ||
| 92 | Biota: bioseston, phytoplankton, phytobenthos, macrozoobenthos, zooplankton, macrophytes, cyanobacterial blooms | Sampling of biota Regulated area: Sampling |
VZ 04 (ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 10870) | ||
| 93 | Sediments, sludge, suspended solids, earths | Sampling of solid materials Regulated area: Sampling |
VZ 05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15) | ||
| 94 | Drinking and treated water | Sampling of drinking water Regulated area: Sampling |
VZ 06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 95 | Bathing water | Sampling of bathing water Regulated area: Sampling |
VZ 07 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 2. Karlovy Vary | |||||
| 96 | Water, waste water, bathing water | Determination of dissolved oxygen by iodometric titration Regulated area: Tests |
ZCH 01 (ČSN EN 25813) | ||
| 97 | Groundwater, waste water, surface water, raw water, treated water, bathing water | Determination of dissolved oxygen by electrochemistry with a membrane probe Regulated area: Tests |
ZCH 02 (ČSN EN ISO 5814) | ||
| 98 | Groundwater, waste water, surface water, raw water, treated water | Determination of biochemical oxygen demand after n days (BODn) by electrochemistry Regulated area: Tests |
ZCH 03 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 99 | Water, bathing water | Determination of chemical oxygen demand by permanganate (COD-Mn) by titration Regulated area: Tests |
ZCH 04 (ČSN EN ISO 8467) | ||
| 100 | Groundwater, waste water, surface water, raw water, aqueous leachate, process water | Determination of chemical oxygen demand by dichromate (COD-Cr) by spectrophotometry, MERCK kit Regulated area: Tests |
ZCH 06 (ČSN ISO 15705) | ||
| 101 | Water | Determination of absorbance by spectrophotometry Regulated area: Tests |
ZCH 07 (ČSN 75 7360) | ||
| 102 | Drinking water, groundwater, surface water, raw water, treated water, bathing water, process water | Determination of turbidity by turbidimetry Regulated area: Tests |
ZCH 08 (ČSN EN ISO 7027-1) | ||
| 103 | Water, waste water, mineral water, aqueous leachate, process water | Determination of dissolved solids by gravimetry Regulated area: Tests |
ZCH 09 (ČSN 75 7346) | ||
| 104 | Waste water, process water | Determination of dissolved inorganic salts (RAS) by gravimetry Regulated area: Tests |
ZCH 10 (ČSN 75 7347) | ||
| 105 | Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water, process water | Determination of suspended solids by gravimetry, method of filtration through glass fibre filters Regulated area: Tests |
ZCH 11 (ČSN EN 872) | ||
| 106 | Water, waste water, bathing water, aqueous leachate, process water | Determination of electrical conductivity Regulated area: Tests |
ZCH 12 (ČSN EN 27888) | ||
| 107 | Water, waste water, bathing water, aqueous leachate, process water | Determination of pH by potentiometry Regulated area: Tests |
ZCH 13 (ČSN ISO 10523) | ||
| 108 | Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water, process water | Determination of temperature Regulated area: Tests |
ZCH 14 (ČSN 75 7342) | ||
| 109 | Drinking water, groundwater, waste water, surface water, raw water, treated water, mineral water, process water | Determination of acid neutralising capacity KNK by titration, including calculation of the content of carbon dioxide forms from measured values Regulated area: Tests |
ZCH 15 (ČSN EN ISO 9963-1; ČSN 75 7373) | ||
| 110 | Drinking water, groundwater, waste water, surface water, raw water, treated water, bathing water | Determination of colour by spectrophotometry Regulated area: Tests |
ZCH 16 (ČSN EN ISO 7887) | ||
| 111 | Drinking water, groundwater, surface water, raw water, treated water | Determination of humic substances by spectrophotometry Regulated area: Tests |
ZCH 18 (ČSN 75 7536) | ||
| 112 | Drinking water, groundwater, waste water, surface water, raw water, treated water, mineral water, process water | Determination of base neutralising capacity ZNK by titration Regulated area: Tests |
ZCH 32 (ČSN 75 7372) | ||
| 113 | Groundwater, waste water, surface water, raw water, treated water, bathing water | Determination of dissolved oxygen by the optical sensor method Regulated area: Tests |
ZCH 40 (ČSN ISO 17289) | ||
| 114 | Surface water, bathing water | Determination of transparency with a test disc Regulated area: Tests |
VZ 09 (ČSN 75 7340; ČSN EN ISO 7027-2) | ||
| 115 | Drinking water, surface water, treated water, bathing water | Determination of free and total chlorine with a Hach kit and of combined chlorine by calculation from measured values Regulated area: Tests |
VZ 10 (Manuál firmy Hach– Lange) | ||
| 116 | Raw, surface, ground and waste water | Determination of chemical oxygen demand by dichromate (COD-Cr) by titration Regulated area: Tests |
ZCH 05 (ČSN ISO 6060) | ||
| 117 | Raw and surface water | Sampling of surface water Regulated area: Sampling |
VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 118 | Waste water, process water (cooling water, filtered water, boiler water, feed water, condensate) | Sampling of waste water (manual sampling, sampling with an automatic sampler) Regulated area: Sampling |
VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; Vyhláška č. 328/2018 Sb.) | ||
| 119 | Sediments, sludge, suspended solids, earths | Sampling of solid materials Regulated area: Sampling |
VZ 05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15) | ||
| 120 | Drinking and treated water | Sampling of drinking water Regulated area: Sampling |
VZ 06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
Reference standards (206)
EPA Method 1633
EPA Method 1694
EPA Method 5030
EPA Method 8260
HB 01
HB 02
HB 03
HB 04
HB 05
HB 06
HB 07
HB 08
ISO 21675
MB 02
MB 03
MB 04
MB 05
MB 06
MB 07
MB 08
Manuál firmy Hach– Lange
Manuál firmy Hydrolab HL 2017
RA 01
RA 03
RA 04
RA 05
SAA 01
SAA 02
SAA 03
SAA 04
SAA 07
SAA 08
SAA 09
SAA 11
SAA 12
SAA 13
SOA 01
SOA 02
SOA 03
SOA 04
SOA 06
SOA 07
SOA 08
SOA 09
SOA 10
SOA 11
SOA 12
SOA 13
SOA 14
SOA 15
SOA 16
SOA 17
SOA 18
SOA 19
SOA 21
SOA 22
SOA 27
SOA 28
VZ 02
VZ 03
VZ 04
VZ 05
VZ 06
VZ 07
VZ 09
VZ 10
VZ 11
VZ 12
VZ 13
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č. 328/2018 Sb.
ZCH 01
ZCH 02
ZCH 03
ZCH 04
ZCH 05
ZCH 06
ZCH 07
ZCH 08
ZCH 09
ZCH 10
ZCH 11
ZCH 12
ZCH 13
ZCH 14
ZCH 15
ZCH 16
ZCH 17
ZCH 18
ZCH 19
ZCH 20
ZCH 21
ZCH 22
ZCH 23
ZCH 24
ZCH 30
ZCH 31
ZCH 32
ZCH 34
ZCH 35
ZCH 36
ZCH 37
ZCH 38
ZCH 39
ZCH 40
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7373
ČSN 75 7440
ČSN 75 7505:2004
ČSN 75 7506
ČSN 75 7536
ČSN 75 7611
ČSN 75 7612
ČSN 75 7623
ČSN 75 7624
ČSN 75 7701
ČSN 75 7712
ČSN 75 7713
ČSN 75 7714
ČSN 75 7715
ČSN 75 7717
ČSN 75 7737
ČSN 75 7835
ČSN 75 7837
ČSN EN 12673
ČSN EN 12880
ČSN EN 12918
ČSN EN 13137:2018
ČSN EN 13946
ČSN EN 14011
ČSN EN 14039
ČSN EN 14184
ČSN EN 14407
ČSN EN 1484
ČSN EN 15110
ČSN EN 15204
ČSN EN 15637
ČSN EN 15935
ČSN EN 16166
ČSN EN 1622
ČSN EN 17503
ČSN EN 1899-2
ČSN EN 25813
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10870
ČSN EN ISO 11732
ČSN EN ISO 11885
ČSN EN ISO 13395
ČSN EN ISO 14189
ČSN EN ISO 14403-2
ČSN EN ISO 15680
ČSN EN ISO 15681-2
ČSN EN ISO 15682
ČSN EN ISO 16588
ČSN EN ISO 17294-2
ČSN EN ISO 17852
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 21676
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6468
ČSN EN ISO 7027-1
ČSN EN ISO 7027-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10260
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 11083
ČSN ISO 11465
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 21676
ČSN ISO 22743
ČSN ISO 24293
ČSN ISO 5667-10
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6060
ČSN ISO 6439