🇨🇿 Slovácké vodárny a kanalizace, a.s. PL
Water & wastewaterMicrobiologyEnvironment
Slovácké vodárny a kanalizace, a.s. is a laboratory accredited by ČIA under number 1444 (Uherské Hradiště, Czech Republic). Its accreditation scope covers 57 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Water (drinking, between treatment stages, raw, ground, surface), Water (drinking, between treatment stages, raw, hot, ground, surface), Waste water, Water (drinking, between treatment stages, raw, ground, surface, bo….
At a glance
- Accreditation number: ČIA 1444
- Methods in scope: 57
- Types of test objects: 29
- City: Uherské Hradiště, Czech Republic
- Valid until: 09-11-2027
- Accreditation number
- 1444
- Accreditation body
- ČIA
- Address
- Za Olšávkou 290, Sady, 686 01 Uherské Hradiště
- City
- Uherské Hradiště, Czech Republic
- Division
- Dział Laboratoriów Gospodarki Wodnej
- Valid until
- 09-11-2027
What this laboratory tests (29)
- Water (drinking, between treatment stages, raw, ground, surface) — 13 methods
- Water (drinking, between treatment stages, raw, hot, ground, surface) — 6 methods
- Waste water — 4 methods
- Water (drinking, between treatment stages, raw, ground, surface, boiler) — 4 methods
- Sludge — 3 methods
- Water (drinking, between treatment stages, hot) — 2 methods
- Water (drinking, between treatment stages, raw, hot, ground, surface, boiler) — 2 methods
- Water (drinking, raw, ground, surface, waste, sludge liquor) — 2 methods
- Ground water, raw water — 1 method
- Surface water, raw water — 1 method
- Water (drinking, between treatment stages, raw, ground, surface, waste, boiler) — 1 method
- Water (drinking, between treatment stages, raw, ground, surface, waste, sludge liquor) — 1 method
- Water (drinking, between treatment stages, raw, ground, surface, waste) — 1 method
- Water (drinking, between treatment stages, raw, hot, ground, surface, boiler), liquid samples (aqueous solutions of chemicals) — 1 method
- Water (drinking, between treatment stages, raw, hot, ground, surface, waste) — 1 method
- and 14 more
Laboratory sections (2)
- Drinking Water Laboratory — 41 methods
- Waste Water Laboratory — 16 methods
Laboratory locations
- Laboratorium Wód Pitnych — Za Olšávkou 290, Sady
- Laboratorium Ścieków — U Kunovského lesa 1496
Certificate information
- Certificate date
- 04.08.2026
Accreditation scope — test methods (57)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Drinking Water Laboratory | |||||
| 1 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of intestinal enterococci by the membrane filtration method Regulated area: Tests |
SOP 2 (ČSN EN ISO 7899-2) | ||
| 2 | Water (drinking, between treatment stages, raw, hot, ground, surface) | Colony count at 22 °C and 36 °C by direct inoculation in a culture medium Regulated area: Tests |
SOP 3 (ČSN EN ISO 6222) | ||
| 3 | Water (drinking, raw) | Determination of Clostridium perfringens by the membrane filtration method Regulated area: Tests |
SOP 1 (ČSN EN ISO 14189) | ||
| 4 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of bioseston by microscopy Regulated area: Tests |
SOP 5 (ČSN 75 7712) | ||
| 5 | Water (raw, ground, surface) | Determination of thermotolerant coliform bacteria by the membrane filtration method Regulated area: Tests |
SOP 7 (ČSN 75 7835) | ||
| 6 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of abioseston by microscopy Regulated area: Tests |
SOP 8 (ČSN 75 7713) | ||
| 7 | Water (drinking, between treatment stages, raw, hot, ground, surface) | Determination of coliform bacteria and Escherichia coli by the Colilert-18/Quanti-Tray® method Regulated area: Tests |
SOP 9 (ČSN EN ISO 9308-2) | ||
| 8 | Water (drinking, hot, ground, surface) | Determination of Pseudomonas aeruginosa by the membrane filtration method Regulated area: Tests |
SOP 10 (ČSN EN ISO 16266) | ||
| 9 | Water (drinking, hot, surface, ground) | Determination of Legionella bacteria by the membrane filtration method Regulated area: Tests |
SOP 12 (ČSN EN ISO 11731) | ||
| 10 | Water (drinking, between treatment stages, raw, hot, ground, surface) | Determination of Escherichia coli and coliform bacteria by the membrane filtration method Regulated area: Tests |
SOP 15 (ČSN EN ISO 9308-1) | ||
| 11 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of absorbance by spectrophotometry Regulated area: Tests |
SOP 21 (ČSN 75 7360) | ||
| 12 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of ammonium ions by spectrophotometry and ammonium nitrogen by calculation from measured values ammonium ions ammonium nitrogen (calculated) Regulated area: Tests |
SOP 22 (ČSN ISO 7150-1) | ||
| 13 | Water (drinking, between treatment stages, raw, hot, ground, surface) | Determination of colour visually Regulated area: Tests |
SOP 23 (ČSN EN ISO 7887, metoda D) | ||
| 14 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of nitrates by direct UV spectrometry and nitrate nitrogen by calculation from measured values nitrates nitrate nitrogen (calculated) Regulated area: Tests |
SOP 24 (AHEM 21/1976) | ||
| 15 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of nitrites by spectrophotometry Regulated area: Tests |
SOP 25 (ČSN EN 26777) | ||
| 16 | Water (raw, surface, waste) | Determination of adsorbable organically bound halogens (AOX) in an unfiltered sample by coulometry Regulated area: Tests |
SOP 42 (ČSN EN ISO 9562) | ||
| 17 | Water (drinking, between treatment stages, raw, hot, ground, surface) | Determination of chemical oxygen demand by permanganate (CODMn) by titration Regulated area: Tests |
SOP 28 (ČSN EN ISO 8467) | ||
| 18 | Water (drinking, between treatment stages, hot) | Determination of free and total chlorine with a commercial HACH kit by spectrophotometry free chlorine total chlorine Regulated area: Tests |
SOP 29 (návod firmy HACH; ČSN EN ISO 7393-2) | ||
| 19 | Water (drinking, between treatment stages, raw, ground, surface, waste, boiler) | Determination of chlorides by Mohr titration Regulated area: Tests |
SOP 50 (ČSN ISO 9297) | ||
| 20 | Water (drinking, raw, hot, ground, surface) | Determination of odour and taste – sensory analysis Regulated area: Tests |
SOP 31 (ČSN 75 7340) | ||
| 21 | Water (drinking, between treatment stages, raw, ground, surface, boiler) | Determination of acid neutralising capacity by titration and conversion to CaCO3 and HCO3- conversion to CaCO3 (calculated), conversion to HCO3- (calculated) Regulated area: Tests |
SOP 32 (ČSN EN ISO 9963-1) | ||
| 22 | Water (drinking, between treatment stages, raw, ground, surface, boiler) | Determination of electrical conductivity Regulated area: Tests |
SOP 33 (ČSN EN 27888) | ||
| 23 | Water (drinking, between treatment stages, raw, hot, ground, surface, boiler), liquid samples (aqueous solutions of chemicals) | Determination of pH by potentiometry Regulated area: Tests |
SOP 34 (ČSN ISO 10523) | ||
| 24 | Water (drinking, between treatment stages, raw, ground, surface, boiler) | Determination of dissolved sulphates – titrimetric method with lead nitrate Regulated area: Tests |
SOP 35 (ČSN 75 7477) | ||
| 25 | Water (drinking, between treatment stages, raw, hot, ground, surface, waste) | Determination of temperature Regulated area: Tests |
SOP 36 (ČSN 75 7342) | ||
| 26 | Water (drinking, between treatment stages, raw, ground, surface, boiler) | Determination of the sum of calcium and magnesium by titration Regulated area: Tests |
SOP 37 (ČSN ISO 6059) | ||
| 27 | Water (drinking, between treatment stages, raw, hot, ground, surface) | Determination of turbidity with an optical turbidimeter Regulated area: Tests |
SOP 38 (ČSN EN ISO 7027-1) | ||
| 28 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of base neutralising capacity by titration and forms of CO2 by calculation from measured values forms of CO2 (calculated) Regulated area: Tests |
SOP 39 (ČSN 75 7372; ČSN 75 7373; ČSN 83 0520-35:1978) | ||
| 29 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of elements by flame AAS (Cu, Zn, Fe, Mn) Copper (Cu) Zinc (Zn) Iron (Fe) Manganese (Mn) Regulated area: Tests |
SOP 40 (ČSN ISO 8288; ČSN 75 7385) | ||
| 30 | Water (drinking, between treatment stages, raw, ground, surface, waste) | Determination of mercury by AAS Regulated area: Tests |
SOP 41 (ČSN 75 7440) | ||
| 31 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of calcium by EDTA titration and of magnesium, calcium hardness and magnesium hardness by calculation from measured values calcium magnesium (calculated), calcium hardness (calculated), magnesium hardness (calculated) Regulated area: Tests |
SOP 44 (ČSN ISO 6058; ČSN ISO 6059) | ||
| 32 | Water (drinking, between treatment stages, raw, hot, ground, surface, boiler) | Determination of total orthophosphates by spectrophotometry Regulated area: Tests |
SOP 51 (ČSN EN ISO 6878) | ||
| 33 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of total cyanides after distillation – photometric method Regulated area: Tests |
SOP 52 (ČSN 75 7415) | ||
| 34 | Water (drinking, between treatment stages, raw, hot, ground, surface, boiler) | Determination of dissolved fluorides, chlorides, nitrites, phosphates, nitrates, sulphates, bromates, chlorites and chlorates by ion chromatography and calculation of the sum of chlorate and chlorite concentrations fluorides chlorides nitrites phosphates nitrates sulphates bromates chlorites chlorates sum of chlorate and chlorite concentrations (calculated) Regulated area: Tests |
SOP 58 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) | ||
| 35 | Water (drinking, between treatment stages, raw, ground, surface, waste, sludge liquor) | Determination of dissolved oxygen by the optical sensor method Regulated area: Tests |
SOP 49 (ČSN ISO 17289) | ||
| 36 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of sodium and potassium by flame emission spectrometry sodium potassium Regulated area: Tests |
SOP 61 (ČSN ISO 9964-3) | ||
| 37 | Water (drinking, between treatment stages, raw, ground, surface) | Determination of elements by electrothermal AAS (Cd, Pb, Ni, Cr, Al, As) Cadmium (Cd) Lead (Pb) Nickel (Ni) Chromium (Cr) Aluminium (Al) Arsenic (As) Regulated area: Tests |
SOP 62 (ČSN EN ISO 15586) | ||
| 38 | Waste water | Determination of cadmium by electrothermal AAS Regulated area: Tests |
SOP 64 (ČSN EN ISO 15586) | ||
| 39 | Water (drinking, between treatment stages, hot) | Sampling of drinking water Regulated area: Sampling |
SOP 1 (ČSN ISO 5667-5; ČSN ISO 5667-21; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 19458) | ||
| 40 | Surface water, raw water | Sampling from reservoirs, rivers and streams (manual sampling) Regulated area: Sampling |
SOP 5 (ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 19458) | ||
| 41 | Ground water, raw water | Sampling of ground water (manual sampling) Regulated area: Sampling |
SOP 6 (ČSN ISO 5667-11; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1; ČSN EN ISO 19458) | ||
| Waste Water Laboratory | |||||
| 42 | Water (waste, surface, sludge liquor) | Determination of pH – water reaction by potentiometry Regulated area: Tests |
SOP 101 (ČSN ISO 10523) | ||
| 43 | Sludge | Determination of pH by potentiometry Regulated area: Tests |
SOP 102 (ČSN EN ISO 10390) | ||
| 44 | Water (raw, surface, ground, waste, between treatment stages), sludge liquor, sludge | Determination of suspended solids and loss on ignition of suspended solids by gravimetry suspended solids loss on ignition of suspended solids Regulated area: Tests |
SOP 103 (ČSN EN 872; ČSN 75 7350) | ||
| 45 | Water (raw, surface, waste, sludge liquor) | Determination of chemical oxygen demand by dichromate, semi-micro method (CODCr) – sealed-tube method Regulated area: Tests |
SOP 104 (ČSN ISO 15705) | ||
| 46 | Water (surface, waste, sludge liquor) | Determination of ammonium nitrogen – titrimetric method, analysis after distillation; inorganic nitrogen by calculation from measured values ammonium nitrogen inorganic nitrogen (calculated) Regulated area: Tests |
SOP 105 (ČSN ISO 5664) | ||
| 47 | Water (raw, waste, surface, ground) | Determination of dissolved solids dried and ignited (RAS) by gravimetry Regulated area: Tests |
SOP 106 (ČSN 75 7346; ČSN 75 7347) | ||
| 48 | Water (raw, surface, ground, waste) | Determination of biochemical oxygen demand with an oxygen electrode (BOD) – method for undiluted samples and dilution method Regulated area: Tests |
SOP 107 (ČSN EN ISO 5815-1) | ||
| 49 | Waste water | Determination of nitrites by spectrophotometry and nitrite nitrogen by calculation from measured values nitrites nitrite nitrogen (calculated) Regulated area: Tests |
SOP 108 (ČSN EN 26777) | ||
| 50 | Water (raw, surface, ground, waste, sludge liquor) | Determination of total phosphorus by spectrophotometry with ammonium molybdate Regulated area: Tests |
SOP 110 (ČSN EN ISO 6878) | ||
| 51 | Sludge | Determination of dry matter and loss on ignition by gravimetry dry matter loss on ignition Regulated area: Tests |
SOP 111 (ČSN EN 15934; ČSN EN 15935) | ||
| 52 | Water (drinking, raw, ground, surface, waste, sludge liquor) | Determination of total nitrogen with a commercial HACH kit by spectrophotometry Regulated area: Tests |
SOP 116 (návod firmy HACH) | ||
| 53 | Waste water | Determination of total fats and oils in waste water – gravimetric method after evaporation of the sample Regulated area: Tests |
SOP 113 (ČSN 75 7509) | ||
| 54 | Waste water | Determination of nitrates by spectrophotometry with 2,6-dimethylphenol and nitrate nitrogen by calculation from measured values nitrates nitrate nitrogen (calculated) Regulated area: Tests |
SOP 115 (ČSN 75 7455) | ||
| 55 | Water (drinking, raw, ground, surface, waste, sludge liquor) | Determination of total nitrogen after oxidative digestion with peroxodisulphate, spectrophotometric determination with 2,6-dimethylphenol – sealed-tube method Regulated area: Tests |
SOP 117 (ČSN EN ISO 11905-1; ČSN 75 7455) | ||
| 56 | Water (waste, sludge liquor) | Sampling of waste water (manual sampling and sampling with an automatic sampler) Regulated area: Sampling |
SOP 2 (ČSN ISO 5667-10; ČSN EN ISO 5667-3; ČSN 75 7315; ČSN EN ISO 5667-14; ČSN EN ISO 5667-1) | ||
| 57 | Sludge | Sampling of sludges (manual sampling) Regulated area: Sampling |
SOP 3 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3; ČSN EN ISO 5667-1) | ||
Reference standards (122)
AHEM 21/1976
SOP 1
SOP 10
SOP 101
SOP 102
SOP 103
SOP 104
SOP 105
SOP 106
SOP 107
SOP 108
SOP 110
SOP 111
SOP 113
SOP 115
SOP 116
SOP 117
SOP 12
SOP 15
SOP 2
SOP 21
SOP 22
SOP 23
SOP 24
SOP 25
SOP 28
SOP 29
SOP 3
SOP 31
SOP 32
SOP 33
SOP 34
SOP 35
SOP 36
SOP 37
SOP 38
SOP 39
SOP 40
SOP 41
SOP 42
SOP 44
SOP 49
SOP 5
SOP 50
SOP 51
SOP 52
SOP 58
SOP 6
SOP 61
SOP 62
SOP 64
SOP 7
SOP 8
SOP 9
návod firmy HACH
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7372
ČSN 75 7373
ČSN 75 7385
ČSN 75 7415
ČSN 75 7440
ČSN 75 7455
ČSN 75 7477
ČSN 75 7509
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 83 0520-35:1978
ČSN EN 15934
ČSN EN 15935
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 11731
ČSN EN ISO 11905-1
ČSN EN ISO 14189
ČSN EN ISO 15061
ČSN EN ISO 15586
ČSN EN ISO 16266
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887, metoda D
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-21
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 7150-1
ČSN ISO 8288
ČSN ISO 9297