🇨🇿 RAKOLAB s.r.o. PL

ČIA 1421 • Rakovník, Czech Republic • 34 methods

Water & wastewaterMicrobiology

RAKOLAB s.r.o. is a laboratory accredited by ČIA under number 1421 (Rakovník, Czech Republic). Its accreditation scope covers 34 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, raw, surface water and bathing water, Drinking, raw and surface water, Drinking, raw, surface and waste water, Drinking, raw, surface, waste water and bathing water. Most frequently used techniques: Spectrophotometric method, Titration, Membrane filtration method.

At a glance

  • Accreditation number: ČIA 1421
  • Methods in scope: 34
  • Types of test objects: 12
  • Techniques used: 11
  • City: Rakovník, Czech Republic
  • Valid until: 09-12-2026
Accreditation number
1421
Accreditation body
ČIA
Address
nábřeží Dr. Beneše 2506, Rakovník II, 269 01 Rakovník
City
Rakovník, Czech Republic
Division
Laboratorium Gospodarki Wodnej
Valid until
09-12-2026

What this laboratory tests (12)

Analytical techniques used (11)

Certificate information

Certificate date
06.01.2022

Accreditation scope — test methods (34)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, raw, surface, waste water and bathing water Determination of ammonium ions (NH4+) spectrophotometrically and of ammoniacal nitrogen (N-NH4+) by calculation
Ammonium ions (NH4+)
Ammoniacal nitrogen (N-NH4+) (calculated) (calculated)
Regulated area: Tests
Spectrophotometric method SOP 1 (ČSN ISO 7150-1)
2 Surface and waste water Determination of biochemical oxygen demand (BOD5) electrochemically with a membrane probe
Regulated area: Tests
Electrochemical method with membrane probe SOP 2 (ČSN EN ISO 5815-1, ČSN EN 1899-2)
3 Surface and waste water Determination of chemical oxygen demand by dichromate (CODCr) by titration
Regulated area: Tests
Titration SOP 3 (ČSN ISO 6060)
4 Drinking, raw, surface, waste water and bathing water Determination of total phosphorus spectrophotometrically
Regulated area: Tests
Spectrophotometric method SOP 4 (ČSN EN ISO 6878)
5 Raw, surface, drinking and waste water Determination of total suspended solids (NL) gravimetrically
Regulated area: Tests
Gravimetric method SOP 5 (ČSN EN 872)
6 Waste water Determination of dissolved solids (RL) at 105 °C and dissolved inorganic salts (RAS) at 550 °C gravimetrically
Dissolved solids (RL) at 105 °C Dissolved inorganic salts (RAS) at 550 °C
Regulated area: Tests
Gravimetric method SOP 6 (ČSN 75 7347, ČSN 75 7346)
7 Drinking, raw, surface, waste water and bathing water Determination of nitrates (NO3-) spectrophotometrically and of nitrate nitrogen (N-NO3-) by calculation
Nitrates (NO3-)
Nitrate nitrogen (N-NO3-) (calculated) (calculated)
Regulated area: Tests
Spectrophotometric method SOP 7 (ČSN ISO 7890-3)
8 Drinking, raw, surface and waste water Determination of nitrites (NO2-) spectrophotometrically and of nitrite nitrogen (N-NO2-) by calculation
Nitrites (NO2-)
Nitrite nitrogen (N-NO2-) (calculated) (calculated)
Regulated area: Tests
Spectrophotometric method SOP 8 (ČSN EN 26777)
9 Drinking, raw and bathing water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Tests
Titration SOP 9 (ČSN EN ISO 8467)
10 Drinking, raw, surface water and bathing water Determination of chlorides by argentometric Mohr method
Regulated area: Tests
Argentometric Mohr method SOP 10 (ČSN ISO 9297)
11 Drinking, raw, surface and waste water Determination of iron spectrophotometrically
Regulated area: Tests
Spectrophotometric method SOP 16 (ČSN ISO 6332)
12 Drinking, raw and surface water Determination of manganese spectrophotometrically
Regulated area: Tests
Spectrophotometric method SOP 17 (ČSN ISO 6333)
13 Drinking, raw, surface and waste water Determination of sulphates by titration
Regulated area: Tests
Titration SOP 18 (ČSN 75 7477)
14 Drinking, raw and surface water Determination of calcium by titration
Regulated area: Tests
Titration SOP 19 (ČSN ISO 6058)
15 Drinking, raw and surface water Determination of the sum of calcium and magnesium by titration and of magnesium by calculation
Sum of calcium and magnesium
Magnesium (calculated) (calculated)
Regulated area: Tests
Titration SOP 20 (ČSN ISO 6059)
16 Drinking, raw, surface, waste water and bathing water Determination of pH by potentiometry
Regulated area: Tests
Potentiometric method SOP 21 (ČSN ISO 10523)
17 Drinking, raw, surface and waste water Determination of electrical conductivity
Regulated area: Tests
SOP 22 (ČSN EN 27888)
18 Drinking and raw water Determination of turbidity turbidimetrically
Regulated area: Tests
Turbidimetric method SOP 23 (ČSN EN ISO 7027-1)
19 Drinking and raw water Determination of acid neutralizing capacity (KNK4.5) by titration
Regulated area: Tests
Titration SOP 24 (ČSN EN ISO 9963-1)
20 Drinking, raw, surface water and bathing water Determination of colour spectrophotometrically
Regulated area: Tests
Spectrophotometric method SOP 25 (ČSN EN ISO 7887)
21 Drinking, raw, surface water and bathing water Determination of aluminium spectrophotometrically
Regulated area: Tests
Spectrophotometric method SOP 37 (ČSN ISO 10566)
22 Drinking, raw, surface water and bathing water Determination of temperature
Regulated area: Tests
SOP 35 (ČSN 75 7342)
23 Drinking water and bathing water Determination of free, total and combined chlorine with HACH commercial test kit
Free chlorine Total chlorine Combined chlorine
Regulated area: Tests
HACH commercial test kit SOP 27 (návod firmy HACH)
24 Surface and waste water Determination of total nitrogen photometrically with HACH commercial test kit and of inorganic nitrogen by calculation
Total nitrogen
Inorganic nitrogen (calculated) (calculated)
Regulated area: Tests
Photometric method, HACH commercial test kit SOP 38 (návod firmy HACH)
25 Drinking, raw, surface water and bathing water Determination of oxidation-reduction potential (ORP)
Regulated area: Tests
SOP 40 (ČSN 75 7367)
26 Drinking, raw and surface water Determination of coliform bacteria in non-disinfected waters by membrane filtration
Regulated area: Tests
Membrane filtration method SOP 11 (ČSN 75 7837)
27 Drinking, raw and surface water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Thermotolerant coliform bacteria Escherichia coli
Regulated area: Tests
Membrane filtration method SOP 12 (ČSN 75 7835)
28 Drinking, raw, surface water and bathing water Enumeration of culturable micro-organisms at 22 °C and 36 °C by inoculation in a nutrient agar culture medium
Culturable micro-organisms at 22 °C Culturable micro-organisms at 36 °C
Regulated area: Tests
Pour plate inoculation in nutrient agar SOP 13 (ČSN EN ISO 6222)
29 Drinking, raw, surface water and bathing water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
Membrane filtration method SOP 15 (ČSN EN ISO 7899-2)
30 Drinking, raw, surface water and bathing water Determination of Escherichia coli and coliform bacteria by membrane filtration
Escherichia coli Coliform bacteria
Regulated area: Tests
Membrane filtration method SOP 36 (ČSN EN ISO 9308-1)
31 Drinking and raw water Sampling of drinking water and raw water used for treatment to drinking water
Regulated area: Sampling
SOP B 1.1.1 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-5, ČSN EN ISO 5667-14, ČSN EN ISO 19458)
32 Waste water Sampling of waste water manually and with an automatic sampler
Regulated area: Sampling
SOP B 1.1.2 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-10, ČSN EN ISO 5667-14)
33 Swimming pool water and bathing water Sampling of swimming pool water and bathing water
Regulated area: Sampling
SOP B 1.1.3 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-14, Vyhláška č.238/2011 Sb., ČSN EN ISO 19458)
34 Surface water Sampling of surface water - manually
Regulated area: Sampling
SOP B 1.1.4 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-4, ČSN EN ISO 5667-6, ČSN EN ISO 5667-14, ČSN EN ISO 19458)

Reference standards (74)

SOP 1
SOP 10
SOP 11
SOP 12
SOP 13
SOP 15
SOP 16
SOP 17
SOP 18
SOP 19
SOP 2
SOP 20
SOP 21
SOP 22
SOP 23
SOP 24
SOP 25
SOP 27
SOP 3
SOP 35
SOP 36
SOP 37
SOP 38
SOP 4
SOP 40
SOP 5
SOP 6
SOP 7
SOP 8
SOP 9
SOP B 1.1.1
SOP B 1.1.2
SOP B 1.1.3
SOP B 1.1.4
Vyhláška č.238/2011 Sb.
návod firmy HACH
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7367
ČSN 75 7477
ČSN 75 7835
ČSN 75 7837
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-14
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 5667-10
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1421