{"lab":{"_id":"69ad52a4de79e566650fd3d8","accr_number":"1421","country":"CZ","accr_body":"ČIA","address":"nábřeží Dr. Beneše 2506, Rakovník II, 269 01 Rakovník","categories":["water","microbiology"],"city":"Rakovník","imported_at":"2026-03-08T10:42:44.590Z","methods_count":34,"name":"RAKOLAB s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1421_20_2022_CS.pdf","1421_20_2022_EN.pdf"],"scope_summary":"Analizy wód pitnych, surowych, powierzchniowych, ścieków i wód w kąpieliskach, pobieranie próbek wód pitnych, surowych, powierzchniowych, ścieków i wód w kąpieliskach.","search_text":"rakolab s.r.o. nábřeží dr. beneše 2506, rakovník ii, 269 01 rakovník 1421","status":"active","updated_at":"2026-03-08T14:52:11.770Z","valid_from":"","valid_until":"09-12-2026","website":"www.rakolab.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.rakolab.cz/kontakt","map_coord":[50.0938,13.74987],"map_geo":"nominatim-street","certificate_date":"06.01.2022","certificate_no":"20/2022","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analizy wód pitnych, surowych, powierzchniowych, ścieków i wód w kąpieliskach, pobieranie próbek wód pitnych, surowych, powierzchniowych, ścieków i wód w kąpieliskach.","en":"Analyses of drinking, raw, surface, waste and bathing waters, sampling of drinking, raw, surface, waste and bathing waters.","zh":"饮用水、原水、地表水、废水和浴场水的分析，饮用水、原水、地表水、废水和浴场水的采样。","cs":"Analýzy pitných, surových, povrchových, odpadních vod a vod ke koupání, vzorkování pitných surových, povrchových, odpadních vod a vod ke koupání."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Gospodarki Wodnej","lab_division_cs":"Vodohospodářská laboratoř","lab_division_en":"Water Management Laboratory","lab_division_zh":"水务实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard operating procedure","zh":"标准操作程序","cs":"Standardní operační postup"},{"abbr":"SOP B","pl":"Standardowa procedura operacyjna pobierania próbek","en":"Standard operating procedure for sampling","zh":"采样标准操作程序","cs":"Standardní operační postup pro vzorkování"},{"abbr":"Vyhláška č. 238/2011 Sb.","pl":"Rozporządzenie ministerstwa zdrowia w sprawie wymagań higienicznych dla kąpielisk, saun i higienicznych limitów piasku w piaskownicach zewnętrznych placów zabaw","en":"Decree of the Ministry of Health on hygienic requirements for bathing facilities, saunas and hygienic limits for sand in sandpits of outdoor playgrounds","zh":"卫生部关于浴场、桑拿卫生要求及室外游乐场沙坑沙子卫生限值的法令","cs":"Vyhláška ministerstva zdravotnictví o stanovení hygienických požadavků na koupaliště, sauny a hygienické limity písku v pískovištích venkovních hracích ploch"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"7e5a7ed6c69fdbd2136a4fa9fde348b77f91ab818d1e0e521612b444c73cf25d","source_pdf_url":"https://www.cai.cz/OA/pdf/P20_2022_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"34de46bbe3461c21d26440c5","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface, waste water and bathing water","test_object_zh":"饮用水、原水、地表水、废水和浴场水","test_object_cs":"Pitná, surová, povrchová, odpadní voda a voda ke koupání","methodology":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną i azotu amonowego (N-NH4+) obliczeniowo","methodology_en":"Determination of ammonium ions (NH4+) spectrophotometrically and of ammoniacal nitrogen (N-NH4+) by calculation","methodology_zh":"分光光度法测定铵离子 (NH4+) 并计算氨氮 (N-NH4+)","methodology_cs":"Stanovení amonných iontů (NH4+) spektrofotometricky a amoniakálního dusíku (N-NH4+) dopočtem","parameters":[{"name":"Jony amonowe (NH4+)","range":""}],"parameters_en":[{"name":"Ammonium ions (NH4+)","range":""}],"parameters_zh":[{"name":"铵离子 (NH4+)","range":""}],"parameters_cs":[{"name":"amonných iontů (NH4+)","range":""}],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["Azot amonowy (N-NH4+) (z obliczeń)"],"computed_en":["Ammoniacal nitrogen (N-NH4+) (calculated)"],"computed_zh":["氨氮 (N-NH4+)（计算）"],"computed_cs":["amoniakálního dusíku (N-NH4+) dopočtem"],"activity":"Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną i azotu amonowego (N-NH4+) obliczeniowo\nJony amonowe (NH4+)\nMetoda spektrofotometryczna","reference":"SOP 1 (ČSN ISO 7150-1)","norm_bases":["SOP 1","ČSN ISO 7150-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach Oznaczanie jonów amonowych (NH4+) metodą spektrofotometryczną i azotu amonowego (N-NH4+) obliczeniowo Metoda spektrofotometryczna Jony amonowe (NH4+)  Azot amonowy (N-NH4+) (z obliczeń) Pitná, surová, povrchová, odpadní voda a voda ke koupání Stanovení amonných iontů (NH4+) spektrofotometricky a amoniakálního dusíku (N-NH4+) dopočtem spektrofotometricky amonných iontů (NH4+)  amoniakálního dusíku (N-NH4+) dopočtem SOP 1 (ČSN ISO 7150-1) Woda pitna, surowa, powierzchniowa, sciekowa i woda w kapieliskach Oznaczanie jonow amonowych (NH4+) metoda spektrofotometryczna i azotu amonowego (N-NH4+) obliczeniowo Metoda spektrofotometryczna Jony amonowe (NH4+)  Azot amonowy (N-NH4+) (z obliczen) Pitna, surova, povrchova, odpadni voda a voda ke koupani Stanoveni amonnych iontu (NH4+) spektrofotometricky a amoniakalniho dusiku (N-NH4+) dopoctem spektrofotometricky amonnych iontu (NH4+)  amoniakalniho dusiku (N-NH4+) dopoctem SOP 1 (CSN ISO 7150-1)","search_en":"Drinking, raw, surface, waste water and bathing water Determination of ammonium ions (NH4+) spectrophotometrically and of ammoniacal nitrogen (N-NH4+) by calculation Spectrophotometric method Ammonium ions (NH4+)  Ammoniacal nitrogen (N-NH4+) (calculated) SOP 1 (ČSN ISO 7150-1)","search_zh":"饮用水、原水、地表水、废水和浴场水 分光光度法测定铵离子 (NH4+) 并计算氨氮 (N-NH4+) 分光光度法 铵离子 (NH4+)  氨氮 (N-NH4+)（计算） SOP 1 (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2d5c6c6b9542571a227599be","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"2","test_object":"Woda powierzchniowa i ściekowa","test_object_en":"Surface and waste water","test_object_zh":"地表水和废水","test_object_cs":"Povrchová a odpadní voda","methodology":"Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metodą elektrochemiczną z sondą membranową","methodology_en":"Determination of biochemical oxygen demand (BOD5) electrochemically with a membrane probe","methodology_zh":"膜电极电化学法测定生化需氧量 (BOD5)","methodology_cs":"Stanovení biochemické spotřeba kyslíku (BSK5) elektrochemicky s membránovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda elektrochemiczna z sondą membranową","technique_en":"Electrochemical method with membrane probe","technique_zh":"膜电极电化学法","technique_cs":"elektrochemicky s membránovou sondou","techniques":["Metoda elektrochemiczna z sondą membranową"],"techniques_en":["Electrochemical method with membrane probe"],"techniques_zh":["膜电极电化学法"],"techniques_cs":["elektrochemicky s membránovou sondou"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metodą elektrochemiczną z sondą membranową\nMetoda elektrochemiczna z sondą membranową","reference":"SOP 2 (ČSN EN ISO 5815-1, ČSN EN 1899-2)","norm_bases":["SOP 2","ČSN EN ISO 5815-1","ČSN EN 1899-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda powierzchniowa i ściekowa Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metodą elektrochemiczną z sondą membranową Metoda elektrochemiczna z sondą membranową Povrchová a odpadní voda Stanovení biochemické spotřeba kyslíku (BSK5) elektrochemicky s membránovou sondou elektrochemicky s membránovou sondou SOP 2 (ČSN EN ISO 5815-1, ČSN EN 1899-2) Woda powierzchniowa i sciekowa Oznaczanie biochemicznego zapotrzebowania na tlen (BZT5) metoda elektrochemiczna z sonda membranowa Metoda elektrochemiczna z sonda membranowa Povrchova a odpadni voda Stanoveni biochemicke spotreba kysliku (BSK5) elektrochemicky s membranovou sondou elektrochemicky s membranovou sondou SOP 2 (CSN EN ISO 5815-1, CSN EN 1899-2)","search_en":"Surface and waste water Determination of biochemical oxygen demand (BOD5) electrochemically with a membrane probe Electrochemical method with membrane probe SOP 2 (ČSN EN ISO 5815-1, ČSN EN 1899-2)","search_zh":"地表水和废水 膜电极电化学法测定生化需氧量 (BOD5) 膜电极电化学法 SOP 2 (ČSN EN ISO 5815-1, ČSN EN 1899-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc0468b81af197274f01da24","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"3","test_object":"Woda powierzchniowa i ściekowa","test_object_en":"Surface and waste water","test_object_zh":"地表水和废水","test_object_cs":"Povrchová a odpadní voda","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZTCr) miareczkowo","methodology_en":"Determination of chemical oxygen demand by dichromate (CODCr) by titration","methodology_zh":"滴定法测定重铬酸盐化学需氧量 (CODCr)","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZTCr) miareczkowo\nMetoda miareczkowa","reference":"SOP 3 (ČSN ISO 6060)","norm_bases":["SOP 3","ČSN ISO 6060"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda powierzchniowa i ściekowa Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZTCr) miareczkowo Metoda miareczkowa Povrchová a odpadní voda Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr) titračně titračně SOP 3 (ČSN ISO 6060) Woda powierzchniowa i sciekowa Oznaczanie chemicznego zapotrzebowania na tlen metoda dwuchromianowa (ChZTCr) miareczkowo Metoda miareczkowa Povrchova a odpadni voda Stanoveni chemicke spotreby kysliku dichromanem (CHSKCr) titracne titracne SOP 3 (CSN ISO 6060)","search_en":"Surface and waste water Determination of chemical oxygen demand by dichromate (CODCr) by titration Titration SOP 3 (ČSN ISO 6060)","search_zh":"地表水和废水 滴定法测定重铬酸盐化学需氧量 (CODCr) 滴定法 SOP 3 (ČSN ISO 6060)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bbb471e3a15ce760f34a3824","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"4","test_object":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface, waste water and bathing water","test_object_zh":"饮用水、原水、地表水、废水和浴场水","test_object_cs":"Pitná, surová, povrchová, odpadní voda a voda ke koupání","methodology":"Oznaczanie fosforu ogólnego metodą spektrofotometryczną","methodology_en":"Determination of total phosphorus spectrophotometrically","methodology_zh":"分光光度法测定总磷","methodology_cs":"Stanovení celkového fosforu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu ogólnego metodą spektrofotometryczną\nMetoda spektrofotometryczna","reference":"SOP 4 (ČSN EN ISO 6878)","norm_bases":["SOP 4","ČSN EN ISO 6878"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach Oznaczanie fosforu ogólnego metodą spektrofotometryczną Metoda spektrofotometryczna Pitná, surová, povrchová, odpadní voda a voda ke koupání Stanovení celkového fosforu spektrofotometricky spektrofotometricky SOP 4 (ČSN EN ISO 6878) Woda pitna, surowa, powierzchniowa, sciekowa i woda w kapieliskach Oznaczanie fosforu ogolnego metoda spektrofotometryczna Metoda spektrofotometryczna Pitna, surova, povrchova, odpadni voda a voda ke koupani Stanoveni celkoveho fosforu spektrofotometricky spektrofotometricky SOP 4 (CSN EN ISO 6878)","search_en":"Drinking, raw, surface, waste water and bathing water Determination of total phosphorus spectrophotometrically Spectrophotometric method SOP 4 (ČSN EN ISO 6878)","search_zh":"饮用水、原水、地表水、废水和浴场水 分光光度法测定总磷 分光光度法 SOP 4 (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e07bf252e8cbf38c57300f1e","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"5","test_object":"Woda surowa, powierzchniowa, pitna i ściekowa","test_object_en":"Raw, surface, drinking and waste water","test_object_zh":"原水、地表水、饮用水和废水","test_object_cs":"Surová, povrchová, pitná a odpadní voda","methodology":"Oznaczanie zawiesin ogólnych (NL) metodą wagową","methodology_en":"Determination of total suspended solids (NL) gravimetrically","methodology_zh":"重量法测定总悬浮物 (NL)","methodology_cs":"Stanovení veškerých nerozpuštěných látek (NL) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda wagowa","technique_en":"Gravimetric method","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesin ogólnych (NL) metodą wagową\nMetoda wagowa","reference":"SOP 5 (ČSN EN 872)","norm_bases":["SOP 5","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda surowa, powierzchniowa, pitna i ściekowa Oznaczanie zawiesin ogólnych (NL) metodą wagową Metoda wagowa Surová, povrchová, pitná a odpadní voda Stanovení veškerých nerozpuštěných látek (NL) gravimetricky gravimetricky SOP 5 (ČSN EN 872) Woda surowa, powierzchniowa, pitna i sciekowa Oznaczanie zawiesin ogolnych (NL) metoda wagowa Metoda wagowa Surova, povrchova, pitna a odpadni voda Stanoveni veskerych nerozpustenych latek (NL) gravimetricky gravimetricky SOP 5 (CSN EN 872)","search_en":"Raw, surface, drinking and waste water Determination of total suspended solids (NL) gravimetrically Gravimetric method SOP 5 (ČSN EN 872)","search_zh":"原水、地表水、饮用水和废水 重量法测定总悬浮物 (NL) 重量法 SOP 5 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2fa2c51794ca52ce1ff0ef5e","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"6","test_object":"Woda ściekowa","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní voda","methodology":"Oznaczanie substancji rozpuszczonych (RL) w 105 °C i rozpuszczonych soli nieorganicznych (RAS) w 550 °C metodą wagową","methodology_en":"Determination of dissolved solids (RL) at 105 °C and dissolved inorganic salts (RAS) at 550 °C gravimetrically","methodology_zh":"重量法测定105 °C溶解性固体 (RL) 和550 °C溶解性无机盐 (RAS)","methodology_cs":"Stanovení rozpuštěných látek (RL) při 105 °C a rozpuštěných anorganických solí (RAS) při 550 °C gravimetricky","parameters":[{"name":"Substancje rozpuszczone (RL) w 105 °C","range":""},{"name":"Rozpuszczone sole nieorganiczne (RAS) w 550 °C","range":""}],"parameters_en":[{"name":"Dissolved solids (RL) at 105 °C","range":""},{"name":"Dissolved inorganic salts (RAS) at 550 °C","range":""}],"parameters_zh":[{"name":"105 °C溶解性固体 (RL)","range":""},{"name":"550 °C溶解性无机盐 (RAS)","range":""}],"parameters_cs":[{"name":"rozpuštěných látek (RL) při 105 °C","range":""},{"name":"rozpuštěných anorganických solí (RAS) při 550 °C","range":""}],"technique":"Metoda wagowa","technique_en":"Gravimetric method","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetric method"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych (RL) w 105 °C i rozpuszczonych soli nieorganicznych (RAS) w 550 °C metodą wagową\nZakres:\nSubstancje rozpuszczone (RL) w 105 °C\nRozpuszczone sole nieorganiczne (RAS) w 550 °C\nMetoda wagowa","reference":"SOP 6 (ČSN 75 7347, ČSN 75 7346)","norm_bases":["SOP 6","ČSN 75 7347","ČSN 75 7346"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda ściekowa Oznaczanie substancji rozpuszczonych (RL) w 105 °C i rozpuszczonych soli nieorganicznych (RAS) w 550 °C metodą wagową Metoda wagowa Substancje rozpuszczone (RL) w 105 °C  Rozpuszczone sole nieorganiczne (RAS) w 550 °C  Odpadní voda Stanovení rozpuštěných látek (RL) při 105 °C a rozpuštěných anorganických solí (RAS) při 550 °C gravimetricky gravimetricky rozpuštěných látek (RL) při 105 °C  rozpuštěných anorganických solí (RAS) při 550 °C  SOP 6 (ČSN 75 7347, ČSN 75 7346) Woda sciekowa Oznaczanie substancji rozpuszczonych (RL) w 105 °C i rozpuszczonych soli nieorganicznych (RAS) w 550 °C metoda wagowa Metoda wagowa Substancje rozpuszczone (RL) w 105 °C  Rozpuszczone sole nieorganiczne (RAS) w 550 °C  Odpadni voda Stanoveni rozpustenych latek (RL) pri 105 °C a rozpustenych anorganickych soli (RAS) pri 550 °C gravimetricky gravimetricky rozpustenych latek (RL) pri 105 °C  rozpustenych anorganickych soli (RAS) pri 550 °C  SOP 6 (CSN 75 7347, CSN 75 7346)","search_en":"Waste water Determination of dissolved solids (RL) at 105 °C and dissolved inorganic salts (RAS) at 550 °C gravimetrically Gravimetric method Dissolved solids (RL) at 105 °C  Dissolved inorganic salts (RAS) at 550 °C  SOP 6 (ČSN 75 7347, ČSN 75 7346)","search_zh":"废水 重量法测定105 °C溶解性固体 (RL) 和550 °C溶解性无机盐 (RAS) 重量法 105 °C溶解性固体 (RL)  550 °C溶解性无机盐 (RAS)  SOP 6 (ČSN 75 7347, ČSN 75 7346)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"75952716a03afe436ddd6d44","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"7","test_object":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface, waste water and bathing water","test_object_zh":"饮用水、原水、地表水、废水和浴场水","test_object_cs":"Pitná, surová, povrchová, odpadní voda a voda ke koupání","methodology":"Oznaczanie azotanów (NO3-) metodą spektrofotometryczną i azotu azotanowego (N-NO3-) obliczeniowo","methodology_en":"Determination of nitrates (NO3-) spectrophotometrically and of nitrate nitrogen (N-NO3-) by calculation","methodology_zh":"分光光度法测定硝酸盐 (NO3-) 并计算硝酸盐氮 (N-NO3-)","methodology_cs":"Stanovení dusičnanů (NO3-) spektrofotometricky a dusičnanového dusíku (N-NO3-) dopočtem","parameters":[{"name":"Azotany (NO3-)","range":""}],"parameters_en":[{"name":"Nitrates (NO3-)","range":""}],"parameters_zh":[{"name":"硝酸盐 (NO3-)","range":""}],"parameters_cs":[{"name":"dusičnanů (NO3-)","range":""}],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["Azot azotanowy (N-NO3-) (z obliczeń)"],"computed_en":["Nitrate nitrogen (N-NO3-) (calculated)"],"computed_zh":["硝酸盐氮 (N-NO3-)（计算）"],"computed_cs":["dusičnanového dusíku (N-NO3-) dopočtem"],"activity":"Oznaczanie azotanów (NO3-) metodą spektrofotometryczną i azotu azotanowego (N-NO3-) obliczeniowo\nAzotany (NO3-)\nMetoda spektrofotometryczna","reference":"SOP 7 (ČSN ISO 7890-3)","norm_bases":["SOP 7","ČSN ISO 7890-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach Oznaczanie azotanów (NO3-) metodą spektrofotometryczną i azotu azotanowego (N-NO3-) obliczeniowo Metoda spektrofotometryczna Azotany (NO3-)  Azot azotanowy (N-NO3-) (z obliczeń) Pitná, surová, povrchová, odpadní voda a voda ke koupání Stanovení dusičnanů (NO3-) spektrofotometricky a dusičnanového dusíku (N-NO3-) dopočtem spektrofotometricky dusičnanů (NO3-)  dusičnanového dusíku (N-NO3-) dopočtem SOP 7 (ČSN ISO 7890-3) Woda pitna, surowa, powierzchniowa, sciekowa i woda w kapieliskach Oznaczanie azotanow (NO3-) metoda spektrofotometryczna i azotu azotanowego (N-NO3-) obliczeniowo Metoda spektrofotometryczna Azotany (NO3-)  Azot azotanowy (N-NO3-) (z obliczen) Pitna, surova, povrchova, odpadni voda a voda ke koupani Stanoveni dusicnanu (NO3-) spektrofotometricky a dusicnanoveho dusiku (N-NO3-) dopoctem spektrofotometricky dusicnanu (NO3-)  dusicnanoveho dusiku (N-NO3-) dopoctem SOP 7 (CSN ISO 7890-3)","search_en":"Drinking, raw, surface, waste water and bathing water Determination of nitrates (NO3-) spectrophotometrically and of nitrate nitrogen (N-NO3-) by calculation Spectrophotometric method Nitrates (NO3-)  Nitrate nitrogen (N-NO3-) (calculated) SOP 7 (ČSN ISO 7890-3)","search_zh":"饮用水、原水、地表水、废水和浴场水 分光光度法测定硝酸盐 (NO3-) 并计算硝酸盐氮 (N-NO3-) 分光光度法 硝酸盐 (NO3-)  硝酸盐氮 (N-NO3-)（计算） SOP 7 (ČSN ISO 7890-3)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7b583e6d955fc10543ef36e8","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"8","test_object":"Woda pitna, surowa, powierzchniowa i ściekowa","test_object_en":"Drinking, raw, surface and waste water","test_object_zh":"饮用水、原水、地表水和废水","test_object_cs":"Pitná, surová, povrchová a odpadní voda","methodology":"Oznaczanie azotynów (NO2-) metodą spektrofotometryczną i azotu azotynowego (N-NO2-) obliczeniowo","methodology_en":"Determination of nitrites (NO2-) spectrophotometrically and of nitrite nitrogen (N-NO2-) by calculation","methodology_zh":"分光光度法测定亚硝酸盐 (NO2-) 并计算亚硝酸盐氮 (N-NO2-)","methodology_cs":"Stanovení dusitanů (NO2-) spektrofotometricky a dusitanového dusíku (N-NO2-) dopočtem","parameters":[{"name":"Azotyny (NO2-)","range":""}],"parameters_en":[{"name":"Nitrites (NO2-)","range":""}],"parameters_zh":[{"name":"亚硝酸盐 (NO2-)","range":""}],"parameters_cs":[{"name":"dusitanů (NO2-)","range":""}],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":["Azot azotynowy (N-NO2-) (z obliczeń)"],"computed_en":["Nitrite nitrogen (N-NO2-) (calculated)"],"computed_zh":["亚硝酸盐氮 (N-NO2-)（计算）"],"computed_cs":["dusitanového dusíku (N-NO2-) dopočtem"],"activity":"Oznaczanie azotynów (NO2-) metodą spektrofotometryczną i azotu azotynowego (N-NO2-) obliczeniowo\nAzotyny (NO2-)\nMetoda spektrofotometryczna","reference":"SOP 8 (ČSN EN 26777)","norm_bases":["SOP 8","ČSN EN 26777"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i ściekowa Oznaczanie azotynów (NO2-) metodą spektrofotometryczną i azotu azotynowego (N-NO2-) obliczeniowo Metoda spektrofotometryczna Azotyny (NO2-)  Azot azotynowy (N-NO2-) (z obliczeń) Pitná, surová, povrchová a odpadní voda Stanovení dusitanů (NO2-) spektrofotometricky a dusitanového dusíku (N-NO2-) dopočtem spektrofotometricky dusitanů (NO2-)  dusitanového dusíku (N-NO2-) dopočtem SOP 8 (ČSN EN 26777) Woda pitna, surowa, powierzchniowa i sciekowa Oznaczanie azotynow (NO2-) metoda spektrofotometryczna i azotu azotynowego (N-NO2-) obliczeniowo Metoda spektrofotometryczna Azotyny (NO2-)  Azot azotynowy (N-NO2-) (z obliczen) Pitna, surova, povrchova a odpadni voda Stanoveni dusitanu (NO2-) spektrofotometricky a dusitanoveho dusiku (N-NO2-) dopoctem spektrofotometricky dusitanu (NO2-)  dusitanoveho dusiku (N-NO2-) dopoctem SOP 8 (CSN EN 26777)","search_en":"Drinking, raw, surface and waste water Determination of nitrites (NO2-) spectrophotometrically and of nitrite nitrogen (N-NO2-) by calculation Spectrophotometric method Nitrites (NO2-)  Nitrite nitrogen (N-NO2-) (calculated) SOP 8 (ČSN EN 26777)","search_zh":"饮用水、原水、地表水和废水 分光光度法测定亚硝酸盐 (NO2-) 并计算亚硝酸盐氮 (N-NO2-) 分光光度法 亚硝酸盐 (NO2-)  亚硝酸盐氮 (N-NO2-)（计算） SOP 8 (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3549b33b6e8839338a9c8cf1","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"9","test_object":"Woda pitna, surowa i woda w kąpieliskach","test_object_en":"Drinking, raw and bathing water","test_object_zh":"饮用水、原水和浴场水","test_object_cs":"Pitná, surová a voda ke koupání","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZTMn, utlenialność) miareczkowo","methodology_en":"Determination of chemical oxygen demand by permanganate (CODMn) by titration","methodology_zh":"滴定法测定高锰酸盐化学需氧量 (CODMn)","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZTMn, utlenialność) miareczkowo\nMetoda miareczkowa","reference":"SOP 9 (ČSN EN ISO 8467)","norm_bases":["SOP 9","ČSN EN ISO 8467"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa i woda w kąpieliskach Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZTMn, utlenialność) miareczkowo Metoda miareczkowa Pitná, surová a voda ke koupání Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně titračně SOP 9 (ČSN EN ISO 8467) Woda pitna, surowa i woda w kapieliskach Oznaczanie chemicznego zapotrzebowania na tlen metoda nadmanganianowa (ChZTMn, utlenialnosc) miareczkowo Metoda miareczkowa Pitna, surova a voda ke koupani Stanoveni chemicke spotreby kysliku manganistanem (CHSKMn) titracne titracne SOP 9 (CSN EN ISO 8467)","search_en":"Drinking, raw and bathing water Determination of chemical oxygen demand by permanganate (CODMn) by titration Titration SOP 9 (ČSN EN ISO 8467)","search_zh":"饮用水、原水和浴场水 滴定法测定高锰酸盐化学需氧量 (CODMn) 滴定法 SOP 9 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c2bf8f88e3da1b2875f01ad","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"10","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie chlorków metodą argentometryczną według Mohra","methodology_en":"Determination of chlorides by argentometric Mohr method","methodology_zh":"莫尔银量法测定氯化物","methodology_cs":"Stanovení chloridů argentometricky metodou podle Mohra","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda argentometryczna Mohra","technique_en":"Argentometric Mohr method","technique_zh":"莫尔银量法","technique_cs":"argentometricky metodou podle Mohra","techniques":["Metoda argentometryczna Mohra"],"techniques_en":["Argentometric Mohr method"],"techniques_zh":["莫尔银量法"],"techniques_cs":["argentometricky metodou podle Mohra"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą argentometryczną według Mohra\nMetoda argentometryczna Mohra","reference":"SOP 10 (ČSN ISO 9297)","norm_bases":["SOP 10","ČSN ISO 9297"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie chlorków metodą argentometryczną według Mohra Metoda argentometryczna Mohra Pitná, surová, povrchová voda a voda ke koupání Stanovení chloridů argentometricky metodou podle Mohra argentometricky metodou podle Mohra SOP 10 (ČSN ISO 9297) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie chlorkow metoda argentometryczna wedlug Mohra Metoda argentometryczna Mohra Pitna, surova, povrchova voda a voda ke koupani Stanoveni chloridu argentometricky metodou podle Mohra argentometricky metodou podle Mohra SOP 10 (CSN ISO 9297)","search_en":"Drinking, raw, surface water and bathing water Determination of chlorides by argentometric Mohr method Argentometric Mohr method SOP 10 (ČSN ISO 9297)","search_zh":"饮用水、原水、地表水和浴场水 莫尔银量法测定氯化物 莫尔银量法 SOP 10 (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eec30845d0d0c30ee91e8a1c","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"11","test_object":"Woda pitna, surowa, powierzchniowa i ściekowa","test_object_en":"Drinking, raw, surface and waste water","test_object_zh":"饮用水、原水、地表水和废水","test_object_cs":"Pitná, surová, povrchová a odpadní voda","methodology":"Oznaczanie żelaza metodą spektrofotometryczną","methodology_en":"Determination of iron spectrophotometrically","methodology_zh":"分光光度法测定铁","methodology_cs":"Stanovení železa spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie żelaza metodą spektrofotometryczną\nMetoda spektrofotometryczna","reference":"SOP 16 (ČSN ISO 6332)","norm_bases":["SOP 16","ČSN ISO 6332"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i ściekowa Oznaczanie żelaza metodą spektrofotometryczną Metoda spektrofotometryczna Pitná, surová, povrchová a odpadní voda Stanovení železa spektrofotometricky spektrofotometricky SOP 16 (ČSN ISO 6332) Woda pitna, surowa, powierzchniowa i sciekowa Oznaczanie zelaza metoda spektrofotometryczna Metoda spektrofotometryczna Pitna, surova, povrchova a odpadni voda Stanoveni zeleza spektrofotometricky spektrofotometricky SOP 16 (CSN ISO 6332)","search_en":"Drinking, raw, surface and waste water Determination of iron spectrophotometrically Spectrophotometric method SOP 16 (ČSN ISO 6332)","search_zh":"饮用水、原水、地表水和废水 分光光度法测定铁 分光光度法 SOP 16 (ČSN ISO 6332)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"881eb50ce1fde79611688515","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"12","test_object":"Woda pitna, surowa i powierzchniowa","test_object_en":"Drinking, raw and surface water","test_object_zh":"饮用水、原水和地表水","test_object_cs":"Pitná, surová a povrchová voda","methodology":"Oznaczanie manganu metodą spektrofotometryczną","methodology_en":"Determination of manganese spectrophotometrically","methodology_zh":"分光光度法测定锰","methodology_cs":"Stanovení manganu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie manganu metodą spektrofotometryczną\nMetoda spektrofotometryczna","reference":"SOP 17 (ČSN ISO 6333)","norm_bases":["SOP 17","ČSN ISO 6333"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa i powierzchniowa Oznaczanie manganu metodą spektrofotometryczną Metoda spektrofotometryczna Pitná, surová a povrchová voda Stanovení manganu spektrofotometricky spektrofotometricky SOP 17 (ČSN ISO 6333) Woda pitna, surowa i powierzchniowa Oznaczanie manganu metoda spektrofotometryczna Metoda spektrofotometryczna Pitna, surova a povrchova voda Stanoveni manganu spektrofotometricky spektrofotometricky SOP 17 (CSN ISO 6333)","search_en":"Drinking, raw and surface water Determination of manganese spectrophotometrically Spectrophotometric method SOP 17 (ČSN ISO 6333)","search_zh":"饮用水、原水和地表水 分光光度法测定锰 分光光度法 SOP 17 (ČSN ISO 6333)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac0a002f6c6fa8992bc35cc3","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"13","test_object":"Woda pitna, surowa, powierzchniowa i ściekowa","test_object_en":"Drinking, raw, surface and waste water","test_object_zh":"饮用水、原水、地表水和废水","test_object_cs":"Pitná, surová, povrchová a odpadní voda","methodology":"Oznaczanie siarczanów metodą miareczkową","methodology_en":"Determination of sulphates by titration","methodology_zh":"滴定法测定硫酸盐","methodology_cs":"Stanovení síranů titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczanów metodą miareczkową\nMetoda miareczkowa","reference":"SOP 18 (ČSN 75 7477)","norm_bases":["SOP 18","ČSN 75 7477"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i ściekowa Oznaczanie siarczanów metodą miareczkową Metoda miareczkowa Pitná, surová, povrchová a odpadní voda Stanovení síranů titračně titračně SOP 18 (ČSN 75 7477) Woda pitna, surowa, powierzchniowa i sciekowa Oznaczanie siarczanow metoda miareczkowa Metoda miareczkowa Pitna, surova, povrchova a odpadni voda Stanoveni siranu titracne titracne SOP 18 (CSN 75 7477)","search_en":"Drinking, raw, surface and waste water Determination of sulphates by titration Titration SOP 18 (ČSN 75 7477)","search_zh":"饮用水、原水、地表水和废水 滴定法测定硫酸盐 滴定法 SOP 18 (ČSN 75 7477)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41f5f6abb1db21a51ab99717","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"14","test_object":"Woda pitna, surowa i powierzchniowa","test_object_en":"Drinking, raw and surface water","test_object_zh":"饮用水、原水和地表水","test_object_cs":"Pitná, surová a povrchová voda","methodology":"Oznaczanie wapnia metodą miareczkową","methodology_en":"Determination of calcium by titration","methodology_zh":"滴定法测定钙","methodology_cs":"Stanovení vápníku titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wapnia metodą miareczkową\nMetoda miareczkowa","reference":"SOP 19 (ČSN ISO 6058)","norm_bases":["SOP 19","ČSN ISO 6058"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa i powierzchniowa Oznaczanie wapnia metodą miareczkową Metoda miareczkowa Pitná, surová a povrchová voda Stanovení vápníku titračně titračně SOP 19 (ČSN ISO 6058) Woda pitna, surowa i powierzchniowa Oznaczanie wapnia metoda miareczkowa Metoda miareczkowa Pitna, surova a povrchova voda Stanoveni vapniku titracne titracne SOP 19 (CSN ISO 6058)","search_en":"Drinking, raw and surface water Determination of calcium by titration Titration SOP 19 (ČSN ISO 6058)","search_zh":"饮用水、原水和地表水 滴定法测定钙 滴定法 SOP 19 (ČSN ISO 6058)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8bf0233c23a805a4bba50e4c","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"15","test_object":"Woda pitna, surowa i powierzchniowa","test_object_en":"Drinking, raw and surface water","test_object_zh":"饮用水、原水和地表水","test_object_cs":"Pitná, surová a povrchová voda","methodology":"Oznaczanie sumy wapnia i magnezu metodą miareczkową oraz magnezu obliczeniowo","methodology_en":"Determination of the sum of calcium and magnesium by titration and of magnesium by calculation","methodology_zh":"滴定法测定钙镁总量并计算镁","methodology_cs":"Stanovení sumy vápníku a hořčíku titračně a hořčíku dopočtem","parameters":[{"name":"Suma wapnia i magnezu","range":""}],"parameters_en":[{"name":"Sum of calcium and magnesium","range":""}],"parameters_zh":[{"name":"钙镁总量","range":""}],"parameters_cs":[{"name":"sumy vápníku a hořčíku","range":""}],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":["Magnez (z obliczeń)"],"computed_en":["Magnesium (calculated)"],"computed_zh":["镁（计算）"],"computed_cs":["hořčíku dopočtem"],"activity":"Oznaczanie sumy wapnia i magnezu metodą miareczkową oraz magnezu obliczeniowo\nSuma wapnia i magnezu\nMetoda miareczkowa","reference":"SOP 20 (ČSN ISO 6059)","norm_bases":["SOP 20","ČSN ISO 6059"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa i powierzchniowa Oznaczanie sumy wapnia i magnezu metodą miareczkową oraz magnezu obliczeniowo Metoda miareczkowa Suma wapnia i magnezu  Magnez (z obliczeń) Pitná, surová a povrchová voda Stanovení sumy vápníku a hořčíku titračně a hořčíku dopočtem titračně sumy vápníku a hořčíku  hořčíku dopočtem SOP 20 (ČSN ISO 6059) Woda pitna, surowa i powierzchniowa Oznaczanie sumy wapnia i magnezu metoda miareczkowa oraz magnezu obliczeniowo Metoda miareczkowa Suma wapnia i magnezu  Magnez (z obliczen) Pitna, surova a povrchova voda Stanoveni sumy vapniku a horciku titracne a horciku dopoctem titracne sumy vapniku a horciku  horciku dopoctem SOP 20 (CSN ISO 6059)","search_en":"Drinking, raw and surface water Determination of the sum of calcium and magnesium by titration and of magnesium by calculation Titration Sum of calcium and magnesium  Magnesium (calculated) SOP 20 (ČSN ISO 6059)","search_zh":"饮用水、原水和地表水 滴定法测定钙镁总量并计算镁 滴定法 钙镁总量  镁（计算） SOP 20 (ČSN ISO 6059)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b10d64e8503d1d865049b7ae","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"16","test_object":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface, waste water and bathing water","test_object_zh":"饮用水、原水、地表水、废水和浴场水","test_object_cs":"Pitná, surová, povrchová, odpadní voda a voda ke koupání","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda potencjometryczna","technique_en":"Potentiometric method","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["Metoda potencjometryczna"],"techniques_en":["Potentiometric method"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną\nMetoda potencjometryczna","reference":"SOP 21 (ČSN ISO 10523)","norm_bases":["SOP 21","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa, ściekowa i woda w kąpieliskach Oznaczanie pH metodą potencjometryczną Metoda potencjometryczna Pitná, surová, povrchová, odpadní voda a voda ke koupání Stanovení pH potenciometricky potenciometricky SOP 21 (ČSN ISO 10523) Woda pitna, surowa, powierzchniowa, sciekowa i woda w kapieliskach Oznaczanie pH metoda potencjometryczna Metoda potencjometryczna Pitna, surova, povrchova, odpadni voda a voda ke koupani Stanoveni pH potenciometricky potenciometricky SOP 21 (CSN ISO 10523)","search_en":"Drinking, raw, surface, waste water and bathing water Determination of pH by potentiometry Potentiometric method SOP 21 (ČSN ISO 10523)","search_zh":"饮用水、原水、地表水、废水和浴场水 电位法测定pH 电位法 SOP 21 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"53f806549576790c60d5b49d","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"17","test_object":"Woda pitna, surowa, powierzchniowa i ściekowa","test_object_en":"Drinking, raw, surface and waste water","test_object_zh":"饮用水、原水、地表水和废水","test_object_cs":"Pitná, surová, povrchová a odpadní voda","methodology":"Oznaczanie przewodności elektrycznej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率的测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej","reference":"SOP 22 (ČSN EN 27888)","norm_bases":["SOP 22","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i ściekowa Oznaczanie przewodności elektrycznej Pitná, surová, povrchová a odpadní voda Stanovení elektrické konduktivity SOP 22 (ČSN EN 27888) Woda pitna, surowa, powierzchniowa i sciekowa Oznaczanie przewodnosci elektrycznej Pitna, surova, povrchova a odpadni voda Stanoveni elektricke konduktivity SOP 22 (CSN EN 27888)","search_en":"Drinking, raw, surface and waste water Determination of electrical conductivity SOP 22 (ČSN EN 27888)","search_zh":"饮用水、原水、地表水和废水 电导率的测定 SOP 22 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c8088e228d48ea407f96ebc8","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"18","test_object":"Woda pitna i surowa","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitná a surová voda","methodology":"Oznaczanie mętności metodą turbidymetryczną","methodology_en":"Determination of turbidity turbidimetrically","methodology_zh":"比浊法测定浊度","methodology_cs":"Stanovení zákalu turbidimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda turbidymetryczna","technique_en":"Turbidimetric method","technique_zh":"比浊法","technique_cs":"turbidimetricky","techniques":["Metoda turbidymetryczna"],"techniques_en":["Turbidimetric method"],"techniques_zh":["比浊法"],"techniques_cs":["turbidimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą turbidymetryczną\nMetoda turbidymetryczna","reference":"SOP 23 (ČSN EN ISO 7027-1)","norm_bases":["SOP 23","ČSN EN ISO 7027-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna i surowa Oznaczanie mętności metodą turbidymetryczną Metoda turbidymetryczna Pitná a surová voda Stanovení zákalu turbidimetricky turbidimetricky SOP 23 (ČSN EN ISO 7027-1) Woda pitna i surowa Oznaczanie metnosci metoda turbidymetryczna Metoda turbidymetryczna Pitna a surova voda Stanoveni zakalu turbidimetricky turbidimetricky SOP 23 (CSN EN ISO 7027-1)","search_en":"Drinking and raw water Determination of turbidity turbidimetrically Turbidimetric method SOP 23 (ČSN EN ISO 7027-1)","search_zh":"饮用水和原水 比浊法测定浊度 比浊法 SOP 23 (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"481ed69c423bae091b5456cd","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"19","test_object":"Woda pitna i surowa","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitná a surová voda","methodology":"Oznaczanie kwasowej pojemności neutralizacyjnej (KNK4,5 — zasadowość) metodą miareczkową","methodology_en":"Determination of acid neutralizing capacity (KNK4.5) by titration","methodology_zh":"滴定法测定酸中和能力 (KNK4.5)","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK4,5) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasowej pojemności neutralizacyjnej (KNK4,5 — zasadowość) metodą miareczkową\nMetoda miareczkowa","reference":"SOP 24 (ČSN EN ISO 9963-1)","norm_bases":["SOP 24","ČSN EN ISO 9963-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna i surowa Oznaczanie kwasowej pojemności neutralizacyjnej (KNK4,5 — zasadowość) metodą miareczkową Metoda miareczkowa Pitná a surová voda Stanovení kyselinové neutralizační kapacity (KNK4,5) titračně titračně SOP 24 (ČSN EN ISO 9963-1) Woda pitna i surowa Oznaczanie kwasowej pojemnosci neutralizacyjnej (KNK4,5 — zasadowosc) metoda miareczkowa Metoda miareczkowa Pitna a surova voda Stanoveni kyselinove neutralizacni kapacity (KNK4,5) titracne titracne SOP 24 (CSN EN ISO 9963-1)","search_en":"Drinking and raw water Determination of acid neutralizing capacity (KNK4.5) by titration Titration SOP 24 (ČSN EN ISO 9963-1)","search_zh":"饮用水和原水 滴定法测定酸中和能力 (KNK4.5) 滴定法 SOP 24 (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c85e095deaef6793941496a0","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"20","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie barwy metodą spektrofotometryczną","methodology_en":"Determination of colour spectrophotometrically","methodology_zh":"分光光度法测定色度","methodology_cs":"Stanovení barvy spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą spektrofotometryczną\nMetoda spektrofotometryczna","reference":"SOP 25 (ČSN EN ISO 7887)","norm_bases":["SOP 25","ČSN EN ISO 7887"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie barwy metodą spektrofotometryczną Metoda spektrofotometryczna Pitná, surová, povrchová voda a voda ke koupání Stanovení barvy spektrofotometricky spektrofotometricky SOP 25 (ČSN EN ISO 7887) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie barwy metoda spektrofotometryczna Metoda spektrofotometryczna Pitna, surova, povrchova voda a voda ke koupani Stanoveni barvy spektrofotometricky spektrofotometricky SOP 25 (CSN EN ISO 7887)","search_en":"Drinking, raw, surface water and bathing water Determination of colour spectrophotometrically Spectrophotometric method SOP 25 (ČSN EN ISO 7887)","search_zh":"饮用水、原水、地表水和浴场水 分光光度法测定色度 分光光度法 SOP 25 (ČSN EN ISO 7887)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be8224a2693e4c20b5e836d7","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"21","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie glinu metodą spektrofotometryczną","methodology_en":"Determination of aluminium spectrophotometrically","methodology_zh":"分光光度法测定铝","methodology_cs":"Stanovení hliníku spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda spektrofotometryczna","technique_en":"Spectrophotometric method","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["Metoda spektrofotometryczna"],"techniques_en":["Spectrophotometric method"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie glinu metodą spektrofotometryczną\nMetoda spektrofotometryczna","reference":"SOP 37 (ČSN ISO 10566)","norm_bases":["SOP 37","ČSN ISO 10566"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie glinu metodą spektrofotometryczną Metoda spektrofotometryczna Pitná, surová, povrchová voda a voda ke koupání Stanovení hliníku spektrofotometricky spektrofotometricky SOP 37 (ČSN ISO 10566) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie glinu metoda spektrofotometryczna Metoda spektrofotometryczna Pitna, surova, povrchova voda a voda ke koupani Stanoveni hliniku spektrofotometricky spektrofotometricky SOP 37 (CSN ISO 10566)","search_en":"Drinking, raw, surface water and bathing water Determination of aluminium spectrophotometrically Spectrophotometric method SOP 37 (ČSN ISO 10566)","search_zh":"饮用水、原水、地表水和浴场水 分光光度法测定铝 分光光度法 SOP 37 (ČSN ISO 10566)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ffb6b85970e2b5a8d814ac6","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"22","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度的测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"SOP 35 (ČSN 75 7342)","norm_bases":["SOP 35","ČSN 75 7342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie temperatury Pitná, surová, povrchová voda a voda ke koupání Stanovení teploty SOP 35 (ČSN 75 7342) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie temperatury Pitna, surova, povrchova voda a voda ke koupani Stanoveni teploty SOP 35 (CSN 75 7342)","search_en":"Drinking, raw, surface water and bathing water Determination of temperature SOP 35 (ČSN 75 7342)","search_zh":"饮用水、原水、地表水和浴场水 温度的测定 SOP 35 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4022087e7b4c81bd7e71a991","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"23","test_object":"Woda pitna i woda w kąpieliskach","test_object_en":"Drinking water and bathing water","test_object_zh":"饮用水和浴场水","test_object_cs":"Pitná voda a voda ke koupání","methodology":"Oznaczanie chloru wolnego, całkowitego i związanego zestawem komercyjnym firmy HACH","methodology_en":"Determination of free, total and combined chlorine with HACH commercial test kit","methodology_zh":"HACH商品试剂盒测定游离氯、总氯和化合氯","methodology_cs":"Stanovení volného, celkového a vázaného chloru komerční soupravou firmy HACH","parameters":[{"name":"Chlor wolny","range":""},{"name":"Chlor całkowity","range":""},{"name":"Chlor związany","range":""}],"parameters_en":[{"name":"Free chlorine","range":""},{"name":"Total chlorine","range":""},{"name":"Combined chlorine","range":""}],"parameters_zh":[{"name":"游离氯","range":""},{"name":"总氯","range":""},{"name":"化合氯","range":""}],"parameters_cs":[{"name":"volného chloru","range":""},{"name":"celkového chloru","range":""},{"name":"vázaného chloru","range":""}],"technique":"Zestaw komercyjny firmy HACH","technique_en":"HACH commercial test kit","technique_zh":"HACH商品试剂盒","technique_cs":"komerční soupravou firmy HACH","techniques":["Zestaw komercyjny firmy HACH"],"techniques_en":["HACH commercial test kit"],"techniques_zh":["HACH商品试剂盒"],"techniques_cs":["komerční soupravou firmy HACH"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chloru wolnego, całkowitego i związanego zestawem komercyjnym firmy HACH\nZakres:\nChlor wolny\nChlor całkowity\nChlor związany\nZestaw komercyjny firmy HACH","reference":"SOP 27 (návod firmy HACH)","norm_bases":["SOP 27","návod firmy HACH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna i woda w kąpieliskach Oznaczanie chloru wolnego, całkowitego i związanego zestawem komercyjnym firmy HACH Zestaw komercyjny firmy HACH Chlor wolny  Chlor całkowity  Chlor związany  Pitná voda a voda ke koupání Stanovení volného, celkového a vázaného chloru komerční soupravou firmy HACH komerční soupravou firmy HACH volného chloru  celkového chloru  vázaného chloru  SOP 27 (návod firmy HACH) Woda pitna i woda w kapieliskach Oznaczanie chloru wolnego, calkowitego i zwiazanego zestawem komercyjnym firmy HACH Zestaw komercyjny firmy HACH Chlor wolny  Chlor calkowity  Chlor zwiazany  Pitna voda a voda ke koupani Stanoveni volneho, celkoveho a vazaneho chloru komercni soupravou firmy HACH komercni soupravou firmy HACH volneho chloru  celkoveho chloru  vazaneho chloru  SOP 27 (navod firmy HACH)","search_en":"Drinking water and bathing water Determination of free, total and combined chlorine with HACH commercial test kit HACH commercial test kit Free chlorine  Total chlorine  Combined chlorine  SOP 27 (návod firmy HACH)","search_zh":"饮用水和浴场水 HACH商品试剂盒测定游离氯、总氯和化合氯 HACH商品试剂盒 游离氯  总氯  化合氯  SOP 27 (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"85e0891b5fbbe54720f4d3ee","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"24","test_object":"Woda powierzchniowa i ściekowa","test_object_en":"Surface and waste water","test_object_zh":"地表水和废水","test_object_cs":"Povrchová a odpadní voda","methodology":"Oznaczanie azotu ogólnego metodą fotometryczną zestawem komercyjnym firmy HACH i azotu nieorganicznego obliczeniowo","methodology_en":"Determination of total nitrogen photometrically with HACH commercial test kit and of inorganic nitrogen by calculation","methodology_zh":"HACH商品试剂盒光度法测定总氮并计算无机氮","methodology_cs":"Stanovení celkového dusíku fotometricky komerční soupravou firmy HACH a anorganického dusíku dopočtem","parameters":[{"name":"Azot ogólny","range":""}],"parameters_en":[{"name":"Total nitrogen","range":""}],"parameters_zh":[{"name":"总氮","range":""}],"parameters_cs":[{"name":"celkového dusíku","range":""}],"technique":"Metoda fotometryczna, zestaw komercyjny firmy HACH","technique_en":"Photometric method, HACH commercial test kit","technique_zh":"光度法，HACH商品试剂盒","technique_cs":"fotometricky komerční soupravou firmy HACH","techniques":["Metoda fotometryczna, zestaw komercyjny firmy HACH"],"techniques_en":["Photometric method, HACH commercial test kit"],"techniques_zh":["光度法，HACH商品试剂盒"],"techniques_cs":["fotometricky komerční soupravou firmy HACH"],"computed":["Azot nieorganiczny (z obliczeń)"],"computed_en":["Inorganic nitrogen (calculated)"],"computed_zh":["无机氮（计算）"],"computed_cs":["anorganického dusíku dopočtem"],"activity":"Oznaczanie azotu ogólnego metodą fotometryczną zestawem komercyjnym firmy HACH i azotu nieorganicznego obliczeniowo\nAzot ogólny\nMetoda fotometryczna, zestaw komercyjny firmy HACH","reference":"SOP 38 (návod firmy HACH)","norm_bases":["SOP 38","návod firmy HACH"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda powierzchniowa i ściekowa Oznaczanie azotu ogólnego metodą fotometryczną zestawem komercyjnym firmy HACH i azotu nieorganicznego obliczeniowo Metoda fotometryczna, zestaw komercyjny firmy HACH Azot ogólny  Azot nieorganiczny (z obliczeń) Povrchová a odpadní voda Stanovení celkového dusíku fotometricky komerční soupravou firmy HACH a anorganického dusíku dopočtem fotometricky komerční soupravou firmy HACH celkového dusíku  anorganického dusíku dopočtem SOP 38 (návod firmy HACH) Woda powierzchniowa i sciekowa Oznaczanie azotu ogolnego metoda fotometryczna zestawem komercyjnym firmy HACH i azotu nieorganicznego obliczeniowo Metoda fotometryczna, zestaw komercyjny firmy HACH Azot ogolny  Azot nieorganiczny (z obliczen) Povrchova a odpadni voda Stanoveni celkoveho dusiku fotometricky komercni soupravou firmy HACH a anorganickeho dusiku dopoctem fotometricky komercni soupravou firmy HACH celkoveho dusiku  anorganickeho dusiku dopoctem SOP 38 (navod firmy HACH)","search_en":"Surface and waste water Determination of total nitrogen photometrically with HACH commercial test kit and of inorganic nitrogen by calculation Photometric method, HACH commercial test kit Total nitrogen  Inorganic nitrogen (calculated) SOP 38 (návod firmy HACH)","search_zh":"地表水和废水 HACH商品试剂盒光度法测定总氮并计算无机氮 光度法，HACH商品试剂盒 总氮  无机氮（计算） SOP 38 (návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1177439967140c3100726e62","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"25","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie potencjału oksydacyjno-redukcyjnego (ORP)","methodology_en":"Determination of oxidation-reduction potential (ORP)","methodology_zh":"氧化还原电位 (ORP) 的测定","methodology_cs":"Stanovení oxidačně redukčního potenciálu (ORP)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie potencjału oksydacyjno-redukcyjnego (ORP)","reference":"SOP 40 (ČSN 75 7367)","norm_bases":["SOP 40","ČSN 75 7367"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie potencjału oksydacyjno-redukcyjnego (ORP) Pitná, surová, povrchová voda a voda ke koupání Stanovení oxidačně redukčního potenciálu (ORP) SOP 40 (ČSN 75 7367) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie potencjalu oksydacyjno-redukcyjnego (ORP) Pitna, surova, povrchova voda a voda ke koupani Stanoveni oxidacne redukcniho potencialu (ORP) SOP 40 (CSN 75 7367)","search_en":"Drinking, raw, surface water and bathing water Determination of oxidation-reduction potential (ORP) SOP 40 (ČSN 75 7367)","search_zh":"饮用水、原水、地表水和浴场水 氧化还原电位 (ORP) 的测定 SOP 40 (ČSN 75 7367)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4278492a343f39013956341b","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"31","test_object":"Woda pitna, surowa i powierzchniowa","test_object_en":"Drinking, raw and surface water","test_object_zh":"饮用水、原水和地表水","test_object_cs":"Pitná, surová a povrchová voda","methodology":"Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą filtracji membranowej","methodology_en":"Determination of coliform bacteria in non-disinfected waters by membrane filtration","methodology_zh":"膜过滤法测定未消毒水中的大肠菌群","methodology_cs":"Stanovení koliformních bakterií v nedezinfikovaných vodách membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda filtracji membranowej","technique_en":"Membrane filtration method","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["Metoda filtracji membranowej"],"techniques_en":["Membrane filtration method"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą filtracji membranowej\nMetoda filtracji membranowej","reference":"SOP 11 (ČSN 75 7837)","norm_bases":["SOP 11","ČSN 75 7837"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa i powierzchniowa Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą filtracji membranowej Metoda filtracji membranowej Pitná, surová a povrchová voda Stanovení koliformních bakterií v nedezinfikovaných vodách membránovou filtrací membránovou filtrací SOP 11 (ČSN 75 7837) Woda pitna, surowa i powierzchniowa Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metoda filtracji membranowej Metoda filtracji membranowej Pitna, surova a povrchova voda Stanoveni koliformnich bakterii v nedezinfikovanych vodach membranovou filtraci membranovou filtraci SOP 11 (CSN 75 7837)","search_en":"Drinking, raw and surface water Determination of coliform bacteria in non-disinfected waters by membrane filtration Membrane filtration method SOP 11 (ČSN 75 7837)","search_zh":"饮用水、原水和地表水 膜过滤法测定未消毒水中的大肠菌群 膜过滤法 SOP 11 (ČSN 75 7837)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"05dfe5638c33219edc6e91d8","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"32","test_object":"Woda pitna, surowa i powierzchniowa","test_object_en":"Drinking, raw and surface water","test_object_zh":"饮用水、原水和地表水","test_object_cs":"Pitná, surová a povrchová voda","methodology":"Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą filtracji membranowej","methodology_en":"Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration","methodology_zh":"膜过滤法测定耐热大肠菌群和大肠埃希氏菌","methodology_cs":"Stanovení termotolerantních koliformních bakterií a Escherichia coli membránovou filtrací","parameters":[{"name":"Termotolerancyjne bakterie grupy coli","range":""},{"name":"Escherichia coli","range":""}],"parameters_en":[{"name":"Thermotolerant coliform bacteria","range":""},{"name":"Escherichia coli","range":""}],"parameters_zh":[{"name":"耐热大肠菌群","range":""},{"name":"大肠埃希氏菌","range":""}],"parameters_cs":[{"name":"termotolerantních koliformních bakterií","range":""},{"name":"Escherichia coli","range":""}],"technique":"Metoda filtracji membranowej","technique_en":"Membrane filtration method","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["Metoda filtracji membranowej"],"techniques_en":["Membrane filtration method"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą filtracji membranowej\nZakres:\nTermotolerancyjne bakterie grupy coli\nEscherichia coli\nMetoda filtracji membranowej","reference":"SOP 12 (ČSN 75 7835)","norm_bases":["SOP 12","ČSN 75 7835"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa i powierzchniowa Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą filtracji membranowej Metoda filtracji membranowej Termotolerancyjne bakterie grupy coli  Escherichia coli  Pitná, surová a povrchová voda Stanovení termotolerantních koliformních bakterií a Escherichia coli membránovou filtrací membránovou filtrací termotolerantních koliformních bakterií  Escherichia coli  SOP 12 (ČSN 75 7835) Woda pitna, surowa i powierzchniowa Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metoda filtracji membranowej Metoda filtracji membranowej Termotolerancyjne bakterie grupy coli  Escherichia coli  Pitna, surova a povrchova voda Stanoveni termotolerantnich koliformnich bakterii a Escherichia coli membranovou filtraci membranovou filtraci termotolerantnich koliformnich bakterii  Escherichia coli  SOP 12 (CSN 75 7835)","search_en":"Drinking, raw and surface water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Membrane filtration method Thermotolerant coliform bacteria  Escherichia coli  SOP 12 (ČSN 75 7835)","search_zh":"饮用水、原水和地表水 膜过滤法测定耐热大肠菌群和大肠埃希氏菌 膜过滤法 耐热大肠菌群  大肠埃希氏菌  SOP 12 (ČSN 75 7835)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a05bec14360f02b3b43e914b","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"33","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie liczby mikroorganizmów hodowlanych w 22 °C i 36 °C przez posiew do agarowego podłoża odżywczego","methodology_en":"Enumeration of culturable micro-organisms at 22 °C and 36 °C by inoculation in a nutrient agar culture medium","methodology_zh":"接种营养琼脂培养基法测定22 °C和36 °C可培养微生物","methodology_cs":"Stanovení kultivovaných mikroorganismů při 22 °C a 36 °C očkováním do živného agarového kultivačního média","parameters":[{"name":"Mikroorganizmy hodowlane w 22 °C","range":""},{"name":"Mikroorganizmy hodowlane w 36 °C","range":""}],"parameters_en":[{"name":"Culturable micro-organisms at 22 °C","range":""},{"name":"Culturable micro-organisms at 36 °C","range":""}],"parameters_zh":[{"name":"22 °C可培养微生物","range":""},{"name":"36 °C可培养微生物","range":""}],"parameters_cs":[{"name":"kultivovaných mikroorganismů při 22 °C","range":""},{"name":"kultivovaných mikroorganismů při 36 °C","range":""}],"technique":"Metoda płytkowa - posiew wgłębny do agaru odżywczego","technique_en":"Pour plate inoculation in nutrient agar","technique_zh":"营养琼脂倾注平板接种法","technique_cs":"očkováním do živného agarového kultivačního média","techniques":["Metoda płytkowa - posiew wgłębny do agaru odżywczego"],"techniques_en":["Pour plate inoculation in nutrient agar"],"techniques_zh":["营养琼脂倾注平板接种法"],"techniques_cs":["očkováním do živného agarového kultivačního média"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby mikroorganizmów hodowlanych w 22 °C i 36 °C przez posiew do agarowego podłoża odżywczego\nZakres:\nMikroorganizmy hodowlane w 22 °C\nMikroorganizmy hodowlane w 36 °C\nMetoda płytkowa - posiew wgłębny do agaru odżywczego","reference":"SOP 13 (ČSN EN ISO 6222)","norm_bases":["SOP 13","ČSN EN ISO 6222"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie liczby mikroorganizmów hodowlanych w 22 °C i 36 °C przez posiew do agarowego podłoża odżywczego Metoda płytkowa - posiew wgłębny do agaru odżywczego Mikroorganizmy hodowlane w 22 °C  Mikroorganizmy hodowlane w 36 °C  Pitná, surová, povrchová voda a voda ke koupání Stanovení kultivovaných mikroorganismů při 22 °C a 36 °C očkováním do živného agarového kultivačního média očkováním do živného agarového kultivačního média kultivovaných mikroorganismů při 22 °C  kultivovaných mikroorganismů při 36 °C  SOP 13 (ČSN EN ISO 6222) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie liczby mikroorganizmow hodowlanych w 22 °C i 36 °C przez posiew do agarowego podloza odzywczego Metoda plytkowa - posiew wglebny do agaru odzywczego Mikroorganizmy hodowlane w 22 °C  Mikroorganizmy hodowlane w 36 °C  Pitna, surova, povrchova voda a voda ke koupani Stanoveni kultivovanych mikroorganismu pri 22 °C a 36 °C ockovanim do zivneho agaroveho kultivacniho media ockovanim do zivneho agaroveho kultivacniho media kultivovanych mikroorganismu pri 22 °C  kultivovanych mikroorganismu pri 36 °C  SOP 13 (CSN EN ISO 6222)","search_en":"Drinking, raw, surface water and bathing water Enumeration of culturable micro-organisms at 22 °C and 36 °C by inoculation in a nutrient agar culture medium Pour plate inoculation in nutrient agar Culturable micro-organisms at 22 °C  Culturable micro-organisms at 36 °C  SOP 13 (ČSN EN ISO 6222)","search_zh":"饮用水、原水、地表水和浴场水 接种营养琼脂培养基法测定22 °C和36 °C可培养微生物 营养琼脂倾注平板接种法 22 °C可培养微生物  36 °C可培养微生物  SOP 13 (ČSN EN ISO 6222)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1aaba78899c7e29ac55409d5","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"34","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","methodology_en":"Determination of intestinal enterococci by membrane filtration","methodology_zh":"膜过滤法测定肠球菌","methodology_cs":"Stanovení intestinálních enterokoků membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda filtracji membranowej","technique_en":"Membrane filtration method","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["Metoda filtracji membranowej"],"techniques_en":["Membrane filtration method"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej\nMetoda filtracji membranowej","reference":"SOP 15 (ČSN EN ISO 7899-2)","norm_bases":["SOP 15","ČSN EN ISO 7899-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie enterokoków jelitowych metodą filtracji membranowej Metoda filtracji membranowej Pitná, surová, povrchová voda a voda ke koupání Stanovení intestinálních enterokoků membránovou filtrací membránovou filtrací SOP 15 (ČSN EN ISO 7899-2) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie enterokokow jelitowych metoda filtracji membranowej Metoda filtracji membranowej Pitna, surova, povrchova voda a voda ke koupani Stanoveni intestinalnich enterokoku membranovou filtraci membranovou filtraci SOP 15 (CSN EN ISO 7899-2)","search_en":"Drinking, raw, surface water and bathing water Determination of intestinal enterococci by membrane filtration Membrane filtration method SOP 15 (ČSN EN ISO 7899-2)","search_zh":"饮用水、原水、地表水和浴场水 膜过滤法测定肠球菌 膜过滤法 SOP 15 (ČSN EN ISO 7899-2)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"761fb779ef980307158537f1","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"35","test_object":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach","test_object_en":"Drinking, raw, surface water and bathing water","test_object_zh":"饮用水、原水、地表水和浴场水","test_object_cs":"Pitná, surová, povrchová voda a voda ke koupání","methodology":"Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej","methodology_en":"Determination of Escherichia coli and coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定大肠埃希氏菌和大肠菌群","methodology_cs":"Stanovení Escherichia coli a koliformních bakterií membránovou filtrací","parameters":[{"name":"Escherichia coli","range":""},{"name":"Bakterie grupy coli","range":""}],"parameters_en":[{"name":"Escherichia coli","range":""},{"name":"Coliform bacteria","range":""}],"parameters_zh":[{"name":"大肠埃希氏菌","range":""},{"name":"大肠菌群","range":""}],"parameters_cs":[{"name":"Escherichia coli","range":""},{"name":"koliformních bakterií","range":""}],"technique":"Metoda filtracji membranowej","technique_en":"Membrane filtration method","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["Metoda filtracji membranowej"],"techniques_en":["Membrane filtration method"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej\nZakres:\nEscherichia coli\nBakterie grupy coli\nMetoda filtracji membranowej","reference":"SOP 36 (ČSN EN ISO 9308-1)","norm_bases":["SOP 36","ČSN EN ISO 9308-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa, powierzchniowa i woda w kąpieliskach Oznaczanie Escherichia coli i bakterii grupy coli metodą filtracji membranowej Metoda filtracji membranowej Escherichia coli  Bakterie grupy coli  Pitná, surová, povrchová voda a voda ke koupání Stanovení Escherichia coli a koliformních bakterií membránovou filtrací membránovou filtrací Escherichia coli  koliformních bakterií  SOP 36 (ČSN EN ISO 9308-1) Woda pitna, surowa, powierzchniowa i woda w kapieliskach Oznaczanie Escherichia coli i bakterii grupy coli metoda filtracji membranowej Metoda filtracji membranowej Escherichia coli  Bakterie grupy coli  Pitna, surova, povrchova voda a voda ke koupani Stanoveni Escherichia coli a koliformnich bakterii membranovou filtraci membranovou filtraci Escherichia coli  koliformnich bakterii  SOP 36 (CSN EN ISO 9308-1)","search_en":"Drinking, raw, surface water and bathing water Determination of Escherichia coli and coliform bacteria by membrane filtration Membrane filtration method Escherichia coli  Coliform bacteria  SOP 36 (ČSN EN ISO 9308-1)","search_zh":"饮用水、原水、地表水和浴场水 膜过滤法测定大肠埃希氏菌和大肠菌群 膜过滤法 大肠埃希氏菌  大肠菌群  SOP 36 (ČSN EN ISO 9308-1)","categories":["microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"942e60dc660cf499ad5384ae","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna i surowa","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitná a surová voda","methodology":"Pobieranie próbek wód pitnych i wód surowych używanych do uzdatniania na wodę pitną","methodology_en":"Sampling of drinking water and raw water used for treatment to drinking water","methodology_zh":"饮用水及用于制备饮用水的原水采样","methodology_cs":"Vzorkování pitných vod a surových vod používaných pro úpravu na vody pitné","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód pitnych i wód surowych używanych do uzdatniania na wodę pitną","reference":"SOP B 1.1.1 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-5, ČSN EN ISO 5667-14, ČSN EN ISO 19458)","norm_bases":["SOP B 1.1.1","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-5","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna i surowa Pobieranie próbek wód pitnych i wód surowych używanych do uzdatniania na wodę pitną Pitná a surová voda Vzorkování pitných vod a surových vod používaných pro úpravu na vody pitné SOP B 1.1.1 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-5, ČSN EN ISO 5667-14, ČSN EN ISO 19458) Woda pitna i surowa Pobieranie probek wod pitnych i wod surowych uzywanych do uzdatniania na wode pitna Pitna a surova voda Vzorkovani pitnych vod a surovych vod pouzivanych pro upravu na vody pitne SOP B 1.1.1 (CSN EN ISO 5667-1, CSN EN ISO 5667-3, CSN ISO 5667-5, CSN EN ISO 5667-14, CSN EN ISO 19458)","search_en":"Drinking and raw water Sampling of drinking water and raw water used for treatment to drinking water SOP B 1.1.1 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-5, ČSN EN ISO 5667-14, ČSN EN ISO 19458)","search_zh":"饮用水和原水 饮用水及用于制备饮用水的原水采样 SOP B 1.1.1 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-5, ČSN EN ISO 5667-14, ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a485a45fdf13b37c7e2ad577","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"2","test_object":"Woda ściekowa","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Odpadní voda","methodology":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","methodology_en":"Sampling of waste water manually and with an automatic sampler","methodology_zh":"手工和自动采样器采集废水样品","methodology_cs":"Vzorkování odpadních vod manuálně a automatickým vzorkovačem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem","reference":"SOP B 1.1.2 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-10, ČSN EN ISO 5667-14)","norm_bases":["SOP B 1.1.2","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda ściekowa Pobieranie próbek ścieków ręcznie i automatycznym próbnikiem Odpadní voda Vzorkování odpadních vod manuálně a automatickým vzorkovačem SOP B 1.1.2 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-10, ČSN EN ISO 5667-14) Woda sciekowa Pobieranie probek sciekow recznie i automatycznym probnikiem Odpadni voda Vzorkovani odpadnich vod manualne a automatickym vzorkovacem SOP B 1.1.2 (CSN EN ISO 5667-1, CSN EN ISO 5667-3, CSN ISO 5667-10, CSN EN ISO 5667-14)","search_en":"Waste water Sampling of waste water manually and with an automatic sampler SOP B 1.1.2 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-10, ČSN EN ISO 5667-14)","search_zh":"废水 手工和自动采样器采集废水样品 SOP B 1.1.2 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-10, ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"84bc2a809c3d6c6ac6470f1a","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"3","test_object":"Wody basenowe i wody w kąpieliskach","test_object_en":"Swimming pool water and bathing water","test_object_zh":"泳池水和浴场水","test_object_cs":"Bazénové vody a vody ke koupání","methodology":"Pobieranie próbek wód basenowych i wód w kąpieliskach","methodology_en":"Sampling of swimming pool water and bathing water","methodology_zh":"泳池水和浴场水采样","methodology_cs":"Vzorkování bazénových vod a vod ke koupání","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód basenowych i wód w kąpieliskach","reference":"SOP B 1.1.3 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-14, Vyhláška č.238/2011 Sb., ČSN EN ISO 19458)","norm_bases":["SOP B 1.1.3","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-14","Vyhláška č.238/2011 Sb.","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody basenowe i wody w kąpieliskach Pobieranie próbek wód basenowych i wód w kąpieliskach Bazénové vody a vody ke koupání Vzorkování bazénových vod a vod ke koupání SOP B 1.1.3 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-14, Vyhláška č.238/2011 Sb., ČSN EN ISO 19458) Wody basenowe i wody w kapieliskach Pobieranie probek wod basenowych i wod w kapieliskach Bazenove vody a vody ke koupani Vzorkovani bazenovych vod a vod ke koupani SOP B 1.1.3 (CSN EN ISO 5667-1, CSN EN ISO 5667-3, CSN EN ISO 5667-14, Vyhlaska c.238/2011 Sb., CSN EN ISO 19458)","search_en":"Swimming pool water and bathing water Sampling of swimming pool water and bathing water SOP B 1.1.3 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-14, Vyhláška č.238/2011 Sb., ČSN EN ISO 19458)","search_zh":"泳池水和浴场水 泳池水和浴场水采样 SOP B 1.1.3 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN EN ISO 5667-14, Vyhláška č.238/2011 Sb., ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eccd6377865f00394d98e0db","lab_id":"69ad52a4de79e566650fd3d8","country":"CZ","accr_number":"1421","accr_body":"ČIA","row_label":"4","test_object":"Woda powierzchniowa","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchová voda","methodology":"Pobieranie próbek wód powierzchniowych - ręcznie","methodology_en":"Sampling of surface water - manually","methodology_zh":"地表水采样——手工","methodology_cs":"Vzorkování povrchových vod - manuálně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych - ręcznie","reference":"SOP B 1.1.4 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-4, ČSN EN ISO 5667-6, ČSN EN ISO 5667-14, ČSN EN ISO 19458)","norm_bases":["SOP B 1.1.4","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda powierzchniowa Pobieranie próbek wód powierzchniowych - ręcznie Povrchová voda Vzorkování povrchových vod - manuálně SOP B 1.1.4 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-4, ČSN EN ISO 5667-6, ČSN EN ISO 5667-14, ČSN EN ISO 19458) Woda powierzchniowa Pobieranie probek wod powierzchniowych - recznie Povrchova voda Vzorkovani povrchovych vod - manualne SOP B 1.1.4 (CSN EN ISO 5667-1, CSN EN ISO 5667-3, CSN ISO 5667-4, CSN EN ISO 5667-6, CSN EN ISO 5667-14, CSN EN ISO 19458)","search_en":"Surface water Sampling of surface water - manually SOP B 1.1.4 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-4, ČSN EN ISO 5667-6, ČSN EN ISO 5667-14, ČSN EN ISO 19458)","search_zh":"地表水 地表水采样——手工 SOP B 1.1.4 (ČSN EN ISO 5667-1, ČSN EN ISO 5667-3, ČSN ISO 5667-4, ČSN EN ISO 5667-6, ČSN EN ISO 5667-14, ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}