🇨🇿 Monitoring, s.r.o. PL

ČIA 1416 • Praha 10, Czech Republic • 105 methods

Water & wastewaterEnvironmentMicrobiology

Monitoring, s.r.o. is a laboratory accredited by ČIA under number 1416 (Praha 10, Czech Republic). Its accreditation scope covers 105 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Drinking water, surface water, groundwater, bottled water, waste wa…, Drinking water, surface water, groundwater, bottled water, waste wa…, Drinking water, surface water, groundwater, waste water, leachates,…, Earths, soils, sludge, sediments, waste, composts.

At a glance

  • Accreditation number: ČIA 1416
  • Methods in scope: 105
  • Types of test objects: 56
  • City: Praha 10, Czech Republic
  • Valid until: 08-12-2026
Accreditation number
1416
Accreditation body
ČIA
Address
Radiová 1122/1, Hostivař, 102 00 Praha 10
City
Praha 10, Czech Republic
Division
Laboratorium Analityczne
Valid until
08-12-2026

What this laboratory tests (56)

Certificate information

Certificate date
24.10.2025

Accreditation scope — test methods (105)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking water, surface water, groundwater, bottled water, waste water, hot water, bathing water, leachates, liquid sludge Determination of pH by potentiometry
Regulated area: Tests
SOP 1 část A (ČSN ISO 10523)
2 Earths, soils, sludge, sediments, biowaste, composts Determination of pH by potentiometry
Regulated area: Tests
SOP 1 část B (ČSN 46 5735; ČSN EN ISO 10390; ČSN EN 15933:2013; ČSN EN 13037)
3 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of electrical conductivity by conductometry
Regulated area: Tests
SOP 2 (ČSN EN 27888; ČSN ISO 11265; ČSN EN 13038)
4 Drinking water, surface water, groundwater, waste water Determination of base neutralising capacity (ZNK8.3, ZNK4.5) by titration and of free CO2 and aggressive CO2 according to Lehmann and Reuss by calculation from measured values
Regulated area: Tests
SOP 3 (ČSN 75 7372; ČSN 75 7373; ČSN 83 0520-35:1978)
5 Drinking water, surface water, groundwater, waste water Determination of acid neutralising capacity (KNK4.5, KNK8.3) by titration and of carbonates (CO32-), hydrogen carbonates (HCO3-) and hydroxide ions (OH-) by calculation from measured values
Regulated area: Tests
SOP 4 (ČSN EN ISO 9963-1; ČSN 75 7373)
6 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of dissolved substances dried (RL105) and ignited (RL550) and dissolved inorganic salts (RAS) by gravimetry
Regulated area: Tests
SOP 5 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216)
7 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of calcium by titration
Regulated area: Tests
SOP 6 (ČSN ISO 6058)
8 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of the sum of calcium and magnesium (total hardness) by titration and of magnesium by calculation from measured values
Regulated area: Tests
SOP 7 (ČSN ISO 6059)
9 Drinking water, surface water, groundwater, bottled water, waste water, bathing water, leachates, liquid sludge Determination of ammonium ions (NH4+) by spectrophotometry and of ammoniacal nitrogen (N-NH4+) by calculation from measured values
Regulated area: Tests
SOP 8 (ČSN ISO 7150-1)
10 Drinking water, surface water, groundwater, waste water, leachates, liquid sludge Determination of total phosphorus (Pcelk.) and phosphates (PO43-) by spectrophotometry
Regulated area: Tests
SOP 9 (ČSN EN ISO 6878, kap. 4, 7)
11 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of total and easily liberatable cyanides (CN-) by spectrophotometry after distillation
Regulated area: Tests
SOP 10 (ČSN ISO 6703-2; ČSN 75 7415)
12 Earths, soils, sludge, sediments, waste Determination of total and easily liberatable cyanides (CN-) by spectrophotometry after distillation
Regulated area: Tests
SOP 10 (ČSN ISO 6703-2; ČSN 75 7415)
13 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of sulphates (SO42-) by titration with Chelaton III
Regulated area: Tests
SOP 11 (ČSN 83 0530-21:1978)
14 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of chlorides by titration
Regulated area: Tests
SOP 12 (ČSN ISO 9297)
15 Drinking water, surface water, groundwater, bottled water, waste water, bathing water, leachates, liquid sludge Determination of nitrates (NO3-) by spectrophotometry and of nitrate nitrogen (N-NO3-) and inorganic nitrogen (Nanorg.) by calculation from measured values
Regulated area: Tests
SOP 13 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51)
16 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of nitrites (NO2-) by spectrophotometry and of nitrite nitrogen (N-NO2-) by calculation from measured values
Regulated area: Tests
SOP 14 (ČSN EN 26777)
17 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of fluorides (F-) by potentiometry (ISE)
Regulated area: Tests
SOP 15 (ČSN ISO 10359-1)
18 Drinking water, surface water, groundwater, waste water, leachates, liquid sludge Determination of chemical oxygen demand by dichromate (COD-Cr) by spectrophotometry
Regulated area: Tests
SOP 16 (ČSN ISO 15705)
19 Drinking water, surface water, groundwater, bottled water, waste water, hot water, bathing water Determination of chemical oxygen demand by permanganate (COD-Mn) by titration
Regulated area: Tests
SOP 17 (ČSN EN ISO 8467)
20 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of extractable substances (EL) and non-polar extractable substances (NEL) by infrared spectrometry
Regulated area: Tests
SOP 18 část A (ČSN 75 7505:1998; ČSN 75 7506)
21 Earths, soils, sludge, sediments, waste, composts Determination of extractable substances (EL) and non-polar extractable substances (NEL) by infrared spectrometry
Regulated area: Tests
SOP 18 část B (ČSN 75 7505:1998; ČSN 75 7506)
22 Drinking water, surface water, groundwater, waste water, leachates, liquid sludge Determination of monohydric phenols (phenol index – FNI) by spectrophotometry after distillation
Regulated area: Tests
SOP 19 (ČSN ISO 6439)
23 Earths, soils, sludge, sediments, waste Determination of monohydric phenols (phenol index – FNI) by spectrophotometry after distillation
Regulated area: Tests
SOP 19 (ČSN ISO 6439)
24 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of PAH, PCB and OCP by GC/MS and of their sums by calculation from measured values
Regulated area: Tests
SOP 20 část A (ČSN 75 7554:1998; ČSN EN ISO 6468; ČSN ISO 28540)
25 Earths, soils, sludge, sediments, waste, asphalt, asphalt recyclates, asphalt mixtures, composts, biowaste, quartz and polyurethane filters Determination of PAH, PCB and OCP by GC/MS and of their sums by calculation from measured values
Regulated area: Tests
SOP 20 část B (ČSN 75 7554:1998; ČSN EN ISO 6468; ČSN EN 15527:2009)
26 Oils, insulating and flammable liquids, liquid waste Determination of PCB by GC/MS and of their sum by calculation from measured values
Regulated area: Tests
SOP 20 část C (ČSN EN ISO 6468)
27 Drinking water, surface water, groundwater, bottled water, waste water, hot water, leachates, liquid sludge Determination of volatile organic compounds (VOC) and C5 to C10 and C5 to C16 hydrocarbons by GC/MS and of the sums of THM and BTEX by calculation from measured values
Regulated area: Tests
SOP 21 část A (ČSN ISO 11423-1; ČSN ISO 11423-2; ČSN EN ISO 15680; ČSN EN ISO 20595)
28 Earths, soils, sludge, sediments, waste, composts Determination of volatile organic compounds (VOC) and C5 to C10 and C5 to C16 hydrocarbons by GC/MS and of the sum of BTEX by calculation from measured values
Regulated area: Tests
SOP 21 část B (EPA-Behavior and Determination of Volatile Organic Compounds in Soil, Marti Minnich, 1993; EPA Method SW-846; EPA Method 5035A; EPA Method 5021A; EPA Method 82610D; ČSN EN ISO 22155; ČSN EN ISO 16558-1)
29 Soil air collected on a solid sorbent Determination of volatile organic compounds (VOC) by GC/MS and of the sum of petroleum hydrocarbons by calculation from measured values
Regulated area: Tests
SOP 21 část C (NIOSH Method 1003; NIOSH Method 1500; NIOSH Method 1501; NIOSH Method 1550)
30 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of metals by atomic absorption spectrometry (AAS) – flame technique
Silver (Ag) Aluminium (Al) Arsenic (As) Gold (Au) Boron (B) Barium (Ba) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Hexavalent chromium (CrVI) Copper (Cu) Iron (Fe) Potassium (K) Lithium (Li) Magnesium (Mg) Manganese (Mn) Divalent manganese (MnII) Sodium (Na) Nickel (Ni) Palladium (Pd) Lead (Pb) Platinum (Pt) Strontium (Sr) Vanadium (V) Zinc (Zn)
Regulated area: Tests
SOP 22 část A (ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN 75 7400; ČSN ISO 8288; ČSN ISO 7980; ČSN EN ISO 12020; ČSN EN 1233:1997; TNV 75 7408)
31 Earths, soils, sludge, sediments, waste, composts, biowaste, solid pollutants, airborne dust Determination of metals by atomic absorption spectrometry (AAS) – flame technique
Silver (Ag) Aluminium (Al) Arsenic (As) Gold (Au) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Hexavalent chromium (CrVI) Copper (Cu) Iron (Fe) Potassium (K) Lithium (Li) Magnesium (Mg) Manganese (Mn) Sodium (Na) Nickel (Ni) Lead (Pb) Palladium (Pd) Tin (Sn) Strontium (Sr) Thallium (Tl) Vanadium (V) Zinc (Zn)
Regulated area: Tests
SOP 22 část B (ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN 75 7400; ČSN ISO 8288; ČSN ISO 7980; ČSN EN ISO 12020; ČSN EN 1233:1997; TNV 75 7408; ČSN 46 5735)
32 Oils, insulating and flammable liquids, liquid waste Determination of metals by atomic absorption spectrometry (AAS) – flame technique
Arsenic (As) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Hexavalent chromium (CrVI) Copper (Cu) Iron (Fe) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Tin (Sn) Thallium (Tl) Vanadium (V) Zinc (Zn)
Regulated area: Tests
SOP 22 část C (ČSN 75 7400; ČSN ISO 8288; ČSN ISO 7980; ČSN EN ISO 12020; ČSN EN 1233:1997)
33 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of metals by atomic absorption spectrometry (AAS) with a graphite furnace
Arsenic (As) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Hexavalent chromium (CrVI) Molybdenum (Mo) Nickel (Ni) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Vanadium (V)
Regulated area: Tests
SOP 23 část A (ČSN EN ISO15586; ČSN EN 1233:1997)
34 Earths, soils, sludge, sediments, waste, composts, biowaste, solid pollutants, airborne dust Determination of metals by atomic absorption spectrometry (AAS) with a graphite furnace
Arsenic (As) Hexavalent chromium (CrVI) Molybdenum (Mo) Antimony (Sb) Selenium (Se)
Regulated area: Tests
SOP 23 část B (ČSN EN ISO 15586; ČSN EN 1233:1997; ČSN 46 5735)
35 Drinking water, surface water, groundwater, bottled water, waste water, leachates, earths, sludge, sediments, waste, composts, biowaste, solid pollutants, airborne dust, oils, insulating and flammable liquids, liquid sludge Determination of mercury with an AMA 254 analyser by atomic absorption spectrometry
Regulated area: Tests
SOP 24 (TNV 75 7440; ČSN 46 5735)
36 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of triazine pesticides and their metabolites by GC/MS and of their sum by calculation from measured values
Regulated area: Tests
SOP 25 část A (ČSN EN ISO 11369)
37 Earths, soils, sludge, sediments, waste, composts, biowaste, solid pollutants, airborne dust Determination of triazine pesticides and their metabolites by GC/MS and of their sum by calculation from measured values
Regulated area: Tests
SOP 25 část B (ČSN EN ISO 11369)
38 Drinking water, surface water, groundwater, waste water, leachates, liquid sludge Determination of C10 to C40 hydrocarbons by GC/FID and of C5 to C40 hydrocarbons by calculation from measured values
Regulated area: Tests
SOP 26 část A (ČSN EN ISO 9377-2; TNV 75 7507)
39 Earths, soils, sludge, sediments, waste, composts Determination of C10 to C40 hydrocarbons by GC/FID and of C5 to C40 hydrocarbons by calculation from measured values
Regulated area: Tests
SOP 26 část B (ČSN EN 14039; ČSN EN ISO 16703)
40 Earths, soils, sludge, sediments, waste, composts, biowaste Determination of dry matter, moisture, loss on ignition (ZŽ) and combustible matter by gravimetry
Regulated area: Tests
SOP 27 (ČSN ISO 11465; ČSN EN 15934; ČSN EN 15935; ČSN EN 15169:2007; ČSN EN 14346:2007; ČSN 46 5735)
41 Drinking water, surface water, groundwater, waste water, liquid sludge Determination of suspended solids dried (NL105) and ignited (NL550) and loss on ignition of suspended solids by gravimetry
Regulated area: Tests
SOP 28 (ČSN EN 872; ČSN 75 7350)
42 Drinking water, surface water, groundwater, bottled water, hot water, bathing water Determination of free and total chlorine with a HANNA commercial analytical kit by colorimetry and of combined chlorine by calculation from measured values
Regulated area: Tests
SOP 29 (návod firmy HANNA; ČSN ISO 7393-2:1995)
43 Surface water, waste water, groundwater Determination of biochemical oxygen demand (BOD5) by titration
Regulated area: Tests
SOP 30 (ČSN EN ISO 5815-1)
44 Bathing water Determination of oxidation-reduction potential (redox potential) by potentiometry
Regulated area: Tests
SOP 31 (ČSN 75 7367)
45 Drinking water, bottled water Indicative sensory determination of odour and taste
Regulated area: Tests
SOP 32 (ČSN 75 7340)
46 Drinking water, surface water, groundwater, bottled water, waste water Determination of colour by spectrophotometry
Regulated area: Tests
SOP 33 (ČSN EN ISO 7887)
47 Drinking water, surface water, groundwater, bottled water, waste water, bathing water Determination of turbidity by nephelometry
Regulated area: Tests
SOP 34 (ČSN EN ISO 7027-1)
48 Composts, biowaste Determination of impurities, non-degradable and undesirable admixtures by gravimetry
Regulated area: Tests
SOP 35 (ČSN 46 5735; Vyhl. č. 273/2021 Sb.)
49 Waste water Determination of fats and oils by gravimetry
Regulated area: Tests
SOP 36 (ČSN 75 7509)
50 Drinking water, bottled water, bathing water Determination of ozone by colorimetry
Regulated area: Tests
SOP 37 (návod firmy Hach)
51 Surface water, groundwater, waste water, leachates, liquid sludge Determination of total nitrogen (Ncelk.) after oxidative digestion by spectrophotometry
Regulated area: Tests
SOP 38 (ČSN EN ISO 11905-1)
52 Drinking water, surface water, groundwater, waste water Determination of dissolved oxygen by electrochemistry
Regulated area: Tests
SOP 39 (ČSN EN ISO 5814)
53 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of hydrogen sulphide (H2S), sulphides (S2-) and hydrogen sulphides (HS-) by photometry
Regulated area: Tests
SOP 40 (návod firmy Merck; ČSN ISO 10530)
54 Drinking water, surface water, groundwater Determination of ferrous iron (FeII+) by spectrophotometry
Regulated area: Tests
SOP 41 (ČSN ISO 6332)
55 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of anionic surfactants with methylene blue (MBAS) by spectrophotometry
Regulated area: Tests
SOP 42 (ČSN EN 903)
56 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of total solids dried (VL105) and ignited (VL550) by gravimetry and of total mineralisation by calculation from measured values
Regulated area: Tests
SOP 43 (ČSN 75 7358; ČSN 75 7346)
57 Drinking water, surface water, groundwater, waste water, leachates, liquid sludge Identification of volatile and semi-volatile substances, identification of the petroleum contamination profile by GC/FID and GC/MS
Regulated area: Tests
SOP 44 část A (knihovna spekter NIST)
58 Earths, soils, sludge, sediments, waste, composts Identification of volatile and semi-volatile substances, identification of the petroleum contamination profile by GC/FID and GC/MS
Regulated area: Tests
SOP 44 část B (knihovna spekter NIST)
59 Soil air collected on a solid sorbent Identification of volatile and semi-volatile substances, identification of the petroleum contamination profile by GC/FID and GC/MS
Regulated area: Tests
SOP 44 část C (knihovna spekter NIST)
60 Groundwater Determination of methane, ethane and ethene by GC/FID
Regulated area: Tests
SOP 45 (Journal of Chromatographic Science, Vol. 49, July 2011: Rapid Analysis of Dissolved Methane, Ethylene, Acetylene and Ethane using Partition Coefficients and Headspace-Gas Chromatography)
61 Groundwater Determination of aggressive CO2 by the Heyer marble test by titration
Regulated area: Tests
SOP 46 (ČSN 83 0520-35:1978)
62 Drinking water, surface water, groundwater, waste water, hot water, bathing water, ambient air Determination of temperature
Regulated area: Tests
SOP 47 (ČSN 75 7342)
63 Drinking water, surface water, groundwater, bottled water, waste water, leachates, bathing water, liquid sludge Determination of anions by ion chromatography and of nitrite nitrogen (N-NO2-) and nitrate nitrogen (N-NO3-) by calculation from measured values
Regulated area: Tests
SOP 48 (ČSN EN ISO 10304-1; ČSN EN ISO 1034-4; ČSN EN ISO 15 061)
64 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of boron by spectrophotometry with azomethine-H
Regulated area: Tests
SOP 59 (ČSN ISO 9390)
65 Earths, soils, sludge, sediments, waste, composts, biowaste Determination of extractable organically bound halogens (EOX) by coulometric titration
Regulated area: Tests
SOP 50 (DIN 38414-17:2014-04)
66 Surface water, groundwater, waste water, process water, pure chemical substances, waste leachates Test of inhibition of the mobility of Daphnia magna Straus (acute toxicity test)
Regulated area: Tests
SOP 51 (ČSN EN ISO 6341)
67 Surface water, groundwater, waste water, process water, pure chemical substances, waste leachates Freshwater algal growth inhibition test with Desmodesmus subspicatus
Regulated area: Tests
SOP 52 (ČSN EN ISO 8692)
68 Surface water, groundwater, waste water, process water, pure chemical substances, waste leachates Test of inhibition of bacterial bioluminescence (Aliivibrio fischeri) (method using dried bacteria)
Regulated area: Tests
SOP 56 (ČSN EN ISO 11348-2)
69 Waste, sludge, soils, earths, sediments, chemical substances Determination of inhibition of lettuce (Lactuca sativa) root growth
Regulated area: Tests
SOP 58 (ČSN EN ISO 11269-1; Vyhl. č. 273/2021 Sb.; Vyhl. č. 8/2021 Sb.)
70 Drinking water, surface water, groundwater, bottled water, waste water, leachates, liquid sludge Determination of adsorbable organically bound halogens (AOX) by coulometric titration
Regulated area: Tests
SOP 49 (ČSN EN ISO 9562)
71 Drinking water, surface water, groundwater, bottled water, waste water, leachates Determination of total organic carbon (TOC) and dissolved organic carbon (DOC), total carbon (TC) and total inorganic carbon (IC) by infrared spectrometry with thermal oxidation
Regulated area: Tests
SOP 60 (ČSN EN 1484)
72 Drinking, hot, bottled, ground, mineral, surface, waste and swimming pool water Enumeration of culturable micro-organisms at 22 °C and 36 °C by inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP 61 (ČSN EN ISO 6222)
73 Drinking, hot, bottled, ground, swimming pool, mineral and surface water Enumeration of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP 62 (ČSN EN ISO 9308-1)
74 Drinking, hot, ground and surface water Enumeration of Escherichia coli and coliform bacteria by the most probable number method (MPN)
Regulated area: Tests
SOP 63 (ČSN EN ISO 9308-2)
75 Drinking, ground, surface and waste water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP 64 (ČSN 75 7835)
76 Drinking, bottled, ground, mineral, surface and waste water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP 65 (ČSN EN ISO 7899-2)
77 Drinking, bottled, hot, swimming pool, mineral and surface water Enumeration of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP 66 (ČSN EN ISO 16266)
78 Drinking and ground water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP 67 (Vyhl. č.70/2017 Sb.,)
79 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP 68 (ČSN EN ISO 14189)
80 Swimming pool, mineral and hot water Enumeration of Staphylococcus aureus by membrane filtration
Regulated area: Tests
SOP 69 (ČSN EN ISO 6888-1)
81 Drinking and swimming pool water Enumeration of Legionella bacteria by membrane filtration
Regulated area: Tests
SOP 70 (ČSN EN ISO 11731)
82 Drinking, bottled, ground, mineral and surface water Determination of bioseston by microscopy
Regulated area: Tests
SOP 71 (ČSN 75 7712)
83 Drinking, ground and surface water Determination of abioseston by microscopy
Regulated area: Tests
SOP 72 (ČSN 75 7713)
84 Surface water, waste water, groundwater Determination of biochemical oxygen demand (BOD5) by electrochemistry
Regulated area: Tests
SOP 73 (ČSN EN ISO 5815-1)
85 Sludge, sediments, composts, biowaste, earths, sand Detection of Salmonella bacteria by culture
Regulated area: Tests
SOP 74 (ČSN EN ISO 6579-1; AHEM 1/2008)
86 Sludge, sediments, composts, biowaste, earths, sand Enumeration of enterococci by direct surface plating
Regulated area: Tests
SOP 75 (ČSN EN ISO 7899-2; AHEM 1/2008)
87 Sludge, sediments, composts, biowaste, earths, sand Enumeration of thermotolerant coliform bacteria and Escherichia coli by direct surface plating
Regulated area: Tests
SOP 76 (ČSN 75 7835; AHEM 1/2008)
88 Drinking, ground, surface and waste water and aqueous leachates Determination of hexavalent chromium (Cr6+) by spectrophotometry
Regulated area: Tests
SOP 77 (ČSN ISO 11083)
89 Drinking water, surface water, groundwater, bottled water, waste water, leachates Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) and stoichiometric calculation of compound contents from measured values and calculation of the sum Ca + Mg and total hardness from measured values
Silver (Ag) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Lithium (Li) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Antimony (Sb) Sulphur (S) Selenium (Se) Silicon (Si) Tin (Sn) Strontium (Sr) Titanium (Ti) Thallium (Tl) Vanadium (V) Zinc (Zn)
Regulated area: Tests
SOP 78, část A (ČSN EN ISO 11885; ČSN EN ISO 15587-1; ČSN EN ISO 15587-2; ČSN 75 7315)
90 Earths, soils, sludge, sediments, waste, composts, biowaste, solid pollutants, airborne dust Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) and stoichiometric calculation of compound content from measured values
Silver (Ag) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Lithium (Li) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Antimony (Sb) Sulphur (S) Selenium (Se) Tin (Sn) Strontium (Sr) Thallium (Tl) Vanadium (V) Zinc (Zn)
Regulated area: Tests
SOP 78, část B (ČSN EN ISO 11885; ČSN 465735; ČSN EN 13657)
91 Composts, earths, sludge, waste, biowaste Determination of four-day respiration activity (AT4) by manometric respirometry
Regulated area: Tests
SOP 79 (Önorm S 2027-4)
92 Drinking water, surface water, groundwater, bottled water, waste water, leachates Determination of total and free cyanides (CN-) by flow analysis with spectrophotometric detection using a SKALAR analyser
Regulated area: Tests
SOP 80 (ČSN EN ISO 14403-2)
93 Drinking water, surface water, groundwater, bottled water, waste water, leachates Determination of monohydric phenols (phenol index FNI) by flow analysis with spectrophotometric detection using a SKALAR analyser
Regulated area: Tests
SOP 81 (ČSN EN ISO 14402)
94 Drinking water, surface water, groundwater, bottled water, waste water, leachates Determination of ammonium ions (NH4+) by flow analysis with spectrophotometric detection using a SKALAR analyser, determination of ammoniacal nitrogen (N-NH4+) by calculation from measured values
Regulated area: Tests
SOP 82 (ČSN EN ISO 11732)
95 Waste water, liquid sludge Manual sampling of waste water and liquid sludge
Regulated area: Sampling
SOP V1 část A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)
96 Waste water Sampling of waste water with an automatic sampler
Regulated area: Sampling
SOP V1 část B (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14)
97 Drinking water, hot water Sampling of drinking and hot water
Regulated area: Sampling
SOP V2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhl. č. 252/2004 Sb.)
98 Surface water Sampling of surface water
Regulated area: Sampling
SOP V3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
99 Earths, soils, composts and compost inputs, biowaste Sampling of earths and soils
Regulated area: Sampling
SOP V4 (ČSN EN ISO 5667-1; Věstník MŽP, 2008, ročník XVIII, částka 4; Vyhl. č. 275/1998 Sb.; ČSN 46 5735)
100 Bathing water, swimming pool and filling water Sampling of water from artificial swimming pools
Regulated area: Sampling
SOP V5 (ČSN EN ISO 5667-1; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 19458; Vyhl. č. 238/2011 Sb.)
101 Groundwater Manual sampling of groundwater
Regulated area: Sampling
SOP V6 část A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
102 Groundwater Sampling of groundwater with a pump
Regulated area: Sampling
SOP V6 část B (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
103 Solid, pasty and liquid waste, earths, sludge, sediments, fly ash, composts and compost inputs, biowaste, construction materials, materials from construction, asphalt slabs, asphalt mixtures Sampling of waste
Regulated area: Sampling
SOP V7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN ISO 5667-16; ČSN EN 14899; ČSN 46 5735; Vyhl. č. 273/2021 Sb.; Metodický pokyn MŽP - Vzorkovací práce v sanační geologii, prosinec 2006; Věstník MŽP, 2008, ročník XVIII, částka 4; Vyhl. č. 283/2023 Sb.)
104 Sediments, sludge Sampling of sediments and sludge
Regulated area: Sampling
SOP V8 (ČSN EN ISO 5667-1; ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN ISO 5667-16; Vyhl. č. 273/2021 Sb.; Vyhl. č. 257/2009 Sb.)
105 Construction materials, asphalt slabs, asphalt recyclates Sampling of construction materials
Regulated area: Sampling
SOP V9 (Vyhláška č. 283/2023 Sb.; ČSN EN 14899; Metodický pokyn MŽP - Vzorkovací práce v sanační geologii, prosinec 2006; Věstník MŽP, 2008, ročník XVIII, částka 4)

Reference standards (255)

AHEM 1/2008
DIN 38414-17:2014-04
EPA Method 5021A
EPA Method 5035A
EPA Method 82610D
EPA Method SW-846
EPA-Behavior and Determination of Volatile Organic Compounds in Soil, Marti Minnich, 1993
Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51
Journal of Chromatographic Science, Vol. 49, July 2011: Rapid Analysis of Dissolved Methane, Ethylene, Acetylene and Ethane using Partition Coefficients and Headspace-Gas Chromatography
Metodický pokyn MŽP - Vzorkovací práce v sanační geologii, prosinec 2006
NIOSH Method 1003
NIOSH Method 1500
NIOSH Method 1501
NIOSH Method 1550
SOP 1 část A
SOP 1 část B
SOP 10
SOP 11
SOP 12
SOP 13
SOP 14
SOP 15
SOP 16
SOP 17
SOP 18 část A
SOP 18 část B
SOP 19
SOP 2
SOP 20 část A
SOP 20 část B
SOP 20 část C
SOP 21 část A
SOP 21 část B
SOP 21 část C
SOP 22 část A
SOP 22 část B
SOP 22 část C
SOP 23 část A
SOP 23 část B
SOP 24
SOP 25 část A
SOP 25 část B
SOP 26 část A
SOP 26 část B
SOP 27
SOP 28
SOP 29
SOP 3
SOP 30
SOP 31
SOP 32
SOP 33
SOP 34
SOP 35
SOP 36
SOP 37
SOP 38
SOP 39
SOP 4
SOP 40
SOP 41
SOP 42
SOP 43
SOP 44 část A
SOP 44 část B
SOP 44 část C
SOP 45
SOP 46
SOP 47
SOP 48
SOP 49
SOP 5
SOP 50
SOP 51
SOP 52
SOP 56
SOP 58
SOP 59
SOP 6
SOP 60
SOP 61
SOP 62
SOP 63
SOP 64
SOP 65
SOP 66
SOP 67
SOP 68
SOP 69
SOP 7
SOP 70
SOP 71
SOP 72
SOP 73
SOP 74
SOP 75
SOP 76
SOP 77
SOP 78, část A
SOP 78, část B
SOP 79
SOP 8
SOP 80
SOP 81
SOP 82
SOP 9
SOP V1 část A
SOP V1 část B
SOP V2
SOP V3
SOP V4
SOP V5
SOP V6 část A
SOP V6 část B
SOP V7
SOP V8
SOP V9
TNV 75 7408
TNV 75 7440
TNV 75 7507
Vyhl. č. 238/2011 Sb.
Vyhl. č. 252/2004 Sb.
Vyhl. č. 257/2009 Sb.
Vyhl. č. 273/2021 Sb.
Vyhl. č. 275/1998 Sb.
Vyhl. č. 283/2023 Sb.
Vyhl. č. 8/2021 Sb.
Vyhl. č.70/2017 Sb.
Vyhláška č. 283/2023 Sb.
Věstník MŽP, 2008, ročník XVIII, částka 4
knihovna spekter NIST
návod firmy HANNA
návod firmy Hach
návod firmy Merck
Önorm S 2027-4
ČSN 46 5735
ČSN 465735
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7358
ČSN 75 7367
ČSN 75 7372
ČSN 75 7373
ČSN 75 7400
ČSN 75 7415
ČSN 75 7505:1998
ČSN 75 7506
ČSN 75 7509
ČSN 75 7554:1998
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 83 0520-35:1978
ČSN 83 0530-21:1978
ČSN EN 1233:1997
ČSN EN 13037
ČSN EN 13038
ČSN EN 13657
ČSN EN 14039
ČSN EN 14346:2007
ČSN EN 1484
ČSN EN 14899
ČSN EN 15169:2007
ČSN EN 15216
ČSN EN 15527:2009
ČSN EN 15933:2013
ČSN EN 15934
ČSN EN 15935
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10304-1
ČSN EN ISO 1034-4
ČSN EN ISO 10390
ČSN EN ISO 11269-1
ČSN EN ISO 11348-2
ČSN EN ISO 11369
ČSN EN ISO 11731
ČSN EN ISO 11732
ČSN EN ISO 11885
ČSN EN ISO 11905-1
ČSN EN ISO 12020
ČSN EN ISO 14189
ČSN EN ISO 14402
ČSN EN ISO 14403-2
ČSN EN ISO 15 061
ČSN EN ISO 15586
ČSN EN ISO 15587-1
ČSN EN ISO 15587-2
ČSN EN ISO 15680
ČSN EN ISO 16266
ČSN EN ISO 16558-1
ČSN EN ISO 16703
ČSN EN ISO 19458
ČSN EN ISO 20595
ČSN EN ISO 22155
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6341
ČSN EN ISO 6468
ČSN EN ISO 6579-1
ČSN EN ISO 6878, kap. 4, 7
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 8692
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN EN ISO15586
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10530
ČSN ISO 11083
ČSN ISO 11265
ČSN ISO 11423-1
ČSN ISO 11423-2
ČSN ISO 11465
ČSN ISO 15705
ČSN ISO 28540
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6439
ČSN ISO 6703-2
ČSN ISO 7150-1
ČSN ISO 7393-2:1995
ČSN ISO 7980
ČSN ISO 8288
ČSN ISO 9297
ČSN ISO 9390
ČSN ISO 9964-1
ČSN ISO 9964-2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1416