🇨🇿 Šumperská provozní vodohospodářská společnost, a.s. PL

ČIA 1404 • Šumperk, Czech Republic • 60 methods

Water & wastewaterMicrobiologyEnvironment

Šumperská provozní vodohospodářská společnost, a.s. is a laboratory accredited by ČIA under number 1404 (Šumperk, Czech Republic). Its accreditation scope covers 60 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, bottled drinking, surface, ground, hot, waste and process…, Drinking, bottled drinking, surface, ground, hot, pool, waste and p…, Drinking, bottled drinking, surface, ground, waste and process water, Sludge.

At a glance

  • Accreditation number: ČIA 1404
  • Methods in scope: 60
  • Types of test objects: 30
  • City: Šumperk, Czech Republic
  • Valid until: 02-04-2031
Accreditation number
1404
Accreditation body
ČIA
Address
Jílová 2769/6, 787 01 Šumperk
City
Šumperk, Czech Republic
Division
Laboratoria Wód Pitnych i Ścieków
Valid until
02-04-2031

What this laboratory tests (30)

Certificate information

Certificate date
02.04.2026

Accreditation scope — test methods (60)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Drinking, bottled drinking, surface, ground, pool, hot, waste and process water Determination of pH by potentiometry
Regulated area: 1 Physical and chemical analyses
SOP 01A (ČSN ISO 10523)
2 Sludge Determination of pH by potentiometry
Regulated area: 1 Physical and chemical analyses
SOP 01B (ČSN EN ISO 10390)
3 Drinking, bottled drinking, surface, ground, hot, waste and process water Determination of conductivity
Regulated area: 1 Physical and chemical analyses
SOP 02 (ČSN EN 27888)
4 Drinking, bottled drinking, surface, ground, hot and process water Determination of colour by spectrophotometry
Regulated area: 1 Physical and chemical analyses
SOP 03 (ČSN EN ISO 7887)
5 Drinking, bottled drinking, surface, ground, hot, pool and process water Determination of turbidity by nephelometry
Regulated area: 1 Physical and chemical analyses
SOP 04 (ČSN EN ISO 7027-1)
6 Drinking, surface, ground, pool and hot water Determination of free and total chlorine by photometry using a Hach commercial analytical kit and combined chlorine by calculation
free chlorine total chlorine
combined chlorine (calculated)
Regulated area: 1 Physical and chemical analyses
SOP 05 (ČSN EN ISO 7393-2; návod firmy Hach)
7 Drinking, bottled drinking, surface, ground, hot, pool, waste and process water, liquid sludge Determination of temperature
Regulated area: 1 Physical and chemical analyses
SOP 07 (ČSN 75 7342)
8 Drinking, bottled drinking, surface and ground water Determination of absorbance at 254 nm (A254) by spectrophotometry
Regulated area: 1 Physical and chemical analyses
SOP 08 (ČSN 75 7360)
9 Drinking, bottled drinking, surface, ground, waste and process water, liquid sludge Determination of dissolved oxygen and oxygen saturation electrochemically
dissolved oxygen oxygen saturation
Regulated area: 1 Physical and chemical analyses
SOP 09 (ČSN EN ISO 5814)
10 Drinking, bottled drinking, surface, ground, hot, waste and process water Determination of dissolved solids and dissolved inorganic salts by gravimetry
dissolved solids dissolved inorganic salts
Regulated area: 1 Physical and chemical analyses
SOP 10 (ČSN 75 7346; ČSN 75 7347)
11 Drinking, bottled drinking, surface, ground, hot, pool, waste and process water Determination of suspended solids by gravimetry
Regulated area: 1 Physical and chemical analyses
SOP 11 (ČSN EN 872)
12 Drinking, bottled drinking, surface, ground and hot water Determination of odour and taste, threshold odour and taste number – indicative sensory analysis
Regulated area: 1 Physical and chemical analyses
SOP 12 (ČSN EN 1622; ČSN 75 7340)
13 Drinking, bottled drinking, surface, ground, waste and process water Determination of acid neutralising capacity (ANC) by titration
Regulated area: 1 Physical and chemical analyses
SOP 13 (ČSN EN ISO 9963-1)
14 Drinking, bottled drinking, surface, ground and pool water Determination of oxidation-reduction potential by potentiometry
Regulated area: 1 Physical and chemical analyses
SOP 14 (ČSN 75 7367)
15 Drinking, bottled drinking, surface, ground, hot, pool, waste and process water Determination of chlorides by titration
Regulated area: 1 Physical and chemical analyses
SOP 15 (ČSN ISO 9297)
16 Drinking, bottled drinking, surface, ground, hot, waste and process water Determination of sulphates by gravimetry
Regulated area: 1 Physical and chemical analyses
SOP 16 (TNV 75 7476)
17 Surface, ground and waste water Determination of chemical oxygen demand by dichromate (CODCr) by the sealed-tube method, spectrophotometrically using a Merck commercial analytical kit
Regulated area: 1 Physical and chemical analyses
SOP 17 (ČSN ISO 15705; návod firmy Merck)
18 Drinking, surface, ground, waste and process water Determination of biochemical oxygen demand (BOD5) electrochemically
Regulated area: 1 Physical and chemical analyses
SOP 18 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
19 Drinking, bottled drinking, surface, ground, hot, pool, waste and process water Determination of ammonium ions by spectrophotometry, ammonium nitrogen by calculation from measured values
ammonium nitrogen (calculated)
Regulated area: 1 Physical and chemical analyses
SOP 19 (ČSN ISO 7150-1)
20 Drinking, bottled drinking, surface, ground, waste and process water Determination of ammonium ions by titration after distillation, ammonium nitrogen by calculation from measured values
ammonium nitrogen (calculated)
Regulated area: 1 Physical and chemical analyses
SOP 20 (ČSN ISO 5664)
21 Drinking, bottled drinking, surface, ground, hot, pool, waste and process water Determination of nitrates by spectrophotometry, nitrate nitrogen by calculation from measured values
nitrate nitrogen (calculated)
Regulated area: 1 Physical and chemical analyses
SOP 21 (ČSN ISO 7890-3)
22 Drinking, bottled drinking, surface, ground, waste and process water Determination of nitrites by spectrophotometry, nitrite nitrogen by calculation from measured values
nitrite nitrogen (calculated)
Regulated area: 1 Physical and chemical analyses
SOP 22 (ČSN EN 26777)
23 Drinking, bottled drinking, surface, ground, hot, waste and process water Determination of phosphates and total phosphorus by spectrophotometry
phosphates total phosphorus
Regulated area: 1 Physical and chemical analyses
SOP 24 (ČSN EN ISO 6878, kap. 4, 7)
24 Drinking, bottled drinking, surface, ground, hot and process water Determination of calcium by titration
Regulated area: 1 Physical and chemical analyses
SOP 25 (ČSN ISO 6058)
25 Drinking, bottled drinking, surface, ground, hot and process water Determination of the sum of calcium and magnesium (hardness) by titration and magnesium by calculation
sum of calcium and magnesium (hardness)
magnesium (calculated)
Regulated area: 1 Physical and chemical analyses
SOP 26 (ČSN ISO 6059; ČSN ISO 6058)
26 Drinking, bottled drinking, surface, ground, pool, waste and process water Determination of iron by spectrophotometry
Regulated area: 1 Physical and chemical analyses
SOP 27 (ČSN ISO 6332)
27 Drinking, bottled drinking, surface and ground water Determination of manganese by spectrophotometry
Regulated area: 1 Physical and chemical analyses
SOP 28 (ČSN ISO 6333)
28 Drinking, bottled drinking, surface and ground water Determination of boron by spectrophotometry
Regulated area: 1 Physical and chemical analyses
SOP 30 (ČSN ISO 9390)
29 Drinking, surface, ground, waste and process water Determination of chemical oxygen demand by dichromate (CODCr) by titration
Regulated area: 1 Physical and chemical analyses
SOP 31 (ČSN ISO 6060)
30 Surface, ground and waste water Determination of non-polar extractable substances (NELIR) and extractable substances (ELIR) by IR spectrometry
non-polar extractable substances (NELIR) extractable substances (ELIR)
Regulated area: 1 Physical and chemical analyses
SOP 34 (ČSN 75 7505:1998; ČSN 75 7506)
31 Drinking, bottled drinking, surface, ground and waste water Determination of extractable substances by gravimetry
Regulated area: 1 Physical and chemical analyses
SOP 35 (ČSN 75 7508)
32 Sludge Determination of dry matter and loss on ignition by gravimetry
dry matter loss on ignition
Regulated area: 1 Physical and chemical analyses
SOP 37 (ČSN EN 15934; ČSN EN 15935)
33 Drinking, bottled drinking, surface, ground and process water Determination of base neutralising capacity (BNC) by titration
Regulated area: 1 Physical and chemical analyses
SOP 44 (ČSN 75 7372)
34 Drinking, bottled drinking, surface and ground water Determination of humic substances by spectrophotometry
Regulated area: 1 Physical and chemical analyses
SOP 47 (ČSN 75 7536)
35 Drinking, bottled drinking, surface, ground, waste and process water Determination of total cyanides after distillation by spectrophotometry – using a Merck commercial analytical kit
Regulated area: 1 Physical and chemical analyses
SOP 55 (ČSN 75 7415; návod firmy Merck)
36 Drinking and hot water Determination of chlorine dioxide by photometry using a Hach commercial analytical kit
Regulated area: 1 Physical and chemical analyses
SOP 57 (návod firmy Hach)
37 Drinking, surface, pool and hot water Determination of thermotolerant coliform bacteria and Escherichia coli by the membrane filtration method
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 61 (ČSN 75 7835)
38 Drinking, bottled drinking, surface, ground, hot and pool water Determination of intestinal enterococci by the membrane filtration method
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 62 (ČSN EN ISO 7899-2)
39 Drinking, bottled drinking, surface, ground, pool, hot and process water Determination of Escherichia coli and coliform bacteria by the membrane filtration method
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 63 (ČSN EN ISO 9308-1)
40 Drinking, bottled drinking, surface, ground, pool, hot and process water Determination of culturable micro-organisms a) at 22 °C, b) at 36 °C by direct inoculation into a culture medium
at 22 °C at 36 °C
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 66 (ČSN EN ISO 6222)
41 Drinking, bottled drinking, pool, hot and process water Determination of Pseudomonas aeruginosa by the membrane filtration method
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 67 (ČSN EN ISO 16266)
42 Drinking, pool, hot and process water Determination of Staphylococcus aureus by the membrane filtration method
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 68 (ČSN EN ISO 6888-1)
43 Drinking, bottled drinking and surface water Determination of Clostridium perfringens (including spores) by the membrane filtration method
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 69 (Vyhláška č. 252/2004 Sb.; Vyhláška č. 70/2018 Sb.)
44 Drinking, bottled drinking, surface and process water Determination of the microscopic picture – number of organisms, number of living organisms
number of organisms number of living organisms
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 70 (ČSN 75 7712)
45 Drinking, bottled drinking, surface and process water Determination of the microscopic picture – abioseston
Regulated area: 2 Microbiological and hydrobiological analyses
SOP 71 (ČSN 75 7713)
46 Drinking, bottled drinking, surface, ground, hot, pool, waste and process water Determination of total and dissolved organic carbon (TOC, DOC) after oxidation with IR detection
total organic carbon (TOC) dissolved organic carbon (DOC)
Regulated area: 3 Special analyses
SOP 29 (ČSN EN 1484; návod firmy Analytik Jena)
47 Drinking, bottled drinking, surface, ground and waste water Determination of total bound nitrogen (TNb) after oxidation with electrochemical detection, inorganic and organic nitrogen by calculation
total bound nitrogen (TNb)
inorganic nitrogen (calculated), organic nitrogen (calculated)
Regulated area: 3 Special analyses
SOP 48 (ČSN EN ISO 20236; návod firmy Analytik Jena)
48 Drinking, bottled drinking, surface, ground, hot, waste and process water Determination of metals – Cu, Co, Cr, Ni, Cd, Zn, Pb, Fe, Mn, Al – by flame AAS
Copper (Cu) Cobalt (Co) Chromium (Cr) Nickel (Ni) Cadmium (Cd) Zinc (Zn) Lead (Pb) Iron (Fe) Manganese (Mn) Aluminium (Al)
Regulated area: 3 Special analyses
SOP 51A (ČSN EN ISO 15587-2; ČSN 75 7385; ČSN ISO 8288; ČSN EN ISO 5961; ČSN EN 1233; ČSN EN ISO 12020; aplikační listy firmy GBC)
49 Sludge Determination of metals – Cu, Cr, Ni, Zn, Pb by flame AAS
Copper (Cu) Chromium (Cr) Nickel (Ni) Zinc (Zn) Lead (Pb)
Regulated area: 3 Special analyses
SOP 51B (ČSN EN ISO 54321; aplikační listy firmy GBC)
50 Drinking, bottled drinking, surface, ground, hot, waste and process water Determination of metals – As, Se, Sb, Cd, Cr, Ni, Pb, Be, Al by electrothermal AAS
Arsenic (As) Selenium (Se) Antimony (Sb) Cadmium (Cd) Chromium (Cr) Nickel (Ni) Lead (Pb) Beryllium (Be) Aluminium (Al)
Regulated area: 3 Special analyses
SOP 52A (ČSN EN ISO 15586; ČSN EN ISO 12020; ČSN EN ISO 5961; ČSN EN 1233; aplikační listy firmy GBC)
51 Sludge Determination of metals – As, Cd by electrothermal AAS
Arsenic (As) Cadmium (Cd)
Regulated area: 3 Special analyses
SOP 52B (ČSN EN ISO 54321; ČSN P CEN/TS 16172:2013; aplikační listy firmy GBC)
52 Drinking, bottled drinking, surface, ground and process water Determination of sodium and potassium by AES
sodium potassium
Regulated area: 3 Special analyses
SOP 53 (ČSN ISO 9964-3; Horáková, Lischke, Grünwald: Chemické a fyzikální metody analýzy vod, Praha 1989)
53 Drinking, bottled drinking, surface, ground, waste and process water Determination of mercury using an AMA analyser
Regulated area: 3 Special analyses
SOP 54 (ČSN 75 7440; návod firmy Altec)
54 Drinking, bottled drinking, surface, ground, pool and process water Determination of anions – chlorides, sulphates, nitrates, nitrites, fluorides, phosphates, bromates, chlorites, chlorates by ion chromatography
chlorides sulphates nitrates nitrites fluorides phosphates bromates chlorites chlorates
Regulated area: 3 Special analyses
SOP 56 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)
55 Drinking, bottled drinking, surface, ground, pool, hot and process water Determination of volatile organic compounds (VOC) by gas chromatography (FID, ECD) and sum of trihalomethanes (THM) by calculation
chloroethene (vinyl chloride) 1,2-dichloroethane benzene tetrachloroethene trichloroethene trichloromethane (chloroform) tribromomethane (bromoform) dibromochloromethane bromodichloromethane
sum of THM: trichloromethane, tribromomethane, dibromochloromethane, bromodichloromethane (calculated)
Regulated area: 3 Special analyses
SOP 59 (ČSN EN ISO 15680)
56 Drinking and hot water Sampling of drinking water
Regulated area: Sampling
SPP 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)
57 Waste water Sampling of waste water (manual sampling, sampling with an automatic sampler)
Regulated area: Sampling
SPP 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315; ČSN EN ISO 19458)
58 Surface water Sampling of surface water (manual sampling, sampling with an automatic sampler)
Regulated area: Sampling
SPP 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055)
59 Pool water Sampling of pool water
Regulated area: Sampling
SPP 04 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458; TNV 75 7055)
60 Sludge Sampling of sludge
Regulated area: Sampling
SPP 06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN 16179)

Reference standards (147)

Horáková, Lischke, Grünwald: Chemické a fyzikální metody analýzy vod, Praha 1989
SOP 01A
SOP 01B
SOP 02
SOP 03
SOP 04
SOP 05
SOP 07
SOP 08
SOP 09
SOP 10
SOP 11
SOP 12
SOP 13
SOP 14
SOP 15
SOP 16
SOP 17
SOP 18
SOP 19
SOP 20
SOP 21
SOP 22
SOP 24
SOP 25
SOP 26
SOP 27
SOP 28
SOP 29
SOP 30
SOP 31
SOP 34
SOP 35
SOP 37
SOP 44
SOP 47
SOP 48
SOP 51A
SOP 51B
SOP 52A
SOP 52B
SOP 53
SOP 54
SOP 55
SOP 56
SOP 57
SOP 59
SOP 61
SOP 62
SOP 63
SOP 66
SOP 67
SOP 68
SOP 69
SOP 70
SOP 71
SPP 01
SPP 02
SPP 03
SPP 04
SPP 06
TNV 75 7055
TNV 75 7476
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č. 70/2018 Sb.
aplikační listy firmy GBC
návod firmy Altec
návod firmy Analytik Jena
návod firmy Hach
návod firmy Merck
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7385
ČSN 75 7415
ČSN 75 7440
ČSN 75 7505:1998
ČSN 75 7506
ČSN 75 7508
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN EN 1233
ČSN EN 1484
ČSN EN 15934
ČSN EN 15935
ČSN EN 16179
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 12020
ČSN EN ISO 15061
ČSN EN ISO 15586
ČSN EN ISO 15587-2
ČSN EN ISO 15680
ČSN EN ISO 16266
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 54321
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 5961
ČSN EN ISO 6222
ČSN EN ISO 6878, kap. 4, 7
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 8288
ČSN ISO 9297
ČSN ISO 9390
ČSN ISO 9964-3
ČSN P CEN/TS 16172:2013

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1404