🇨🇿 Šumperská provozní vodohospodářská společnost, a.s. PL
Water & wastewaterMicrobiologyEnvironment
Šumperská provozní vodohospodářská společnost, a.s. is a laboratory accredited by ČIA under number 1404 (Šumperk, Czech Republic). Its accreditation scope covers 60 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, bottled drinking, surface, ground, hot, waste and process…, Drinking, bottled drinking, surface, ground, hot, pool, waste and p…, Drinking, bottled drinking, surface, ground, waste and process water, Sludge.
At a glance
- Accreditation number: ČIA 1404
- Methods in scope: 60
- Types of test objects: 30
- City: Šumperk, Czech Republic
- Valid until: 02-04-2031
- Accreditation number
- 1404
- Accreditation body
- ČIA
- Address
- Jílová 2769/6, 787 01 Šumperk
- City
- Šumperk, Czech Republic
- Division
- Laboratoria Wód Pitnych i Ścieków
- Valid until
- 02-04-2031
What this laboratory tests (30)
- Drinking, bottled drinking, surface, ground, hot, waste and process water — 6 methods
- Drinking, bottled drinking, surface, ground, hot, pool, waste and process water — 5 methods
- Drinking, bottled drinking, surface, ground, waste and process water — 5 methods
- Sludge — 5 methods
- Drinking, bottled drinking, surface and ground water — 4 methods
- Drinking, bottled drinking, surface, ground, hot and process water — 3 methods
- Drinking, bottled drinking, surface, ground, pool, hot and process water — 3 methods
- Drinking and hot water — 2 methods
- Drinking, bottled drinking, surface and process water — 2 methods
- Drinking, bottled drinking, surface, ground and process water — 2 methods
- Drinking, bottled drinking, surface, ground and waste water — 2 methods
- Drinking, surface, ground, waste and process water — 2 methods
- Surface, ground and waste water — 2 methods
- Drinking, bottled drinking and surface water — 1 method
- Drinking, bottled drinking, pool, hot and process water — 1 method
- and 15 more
Certificate information
- Certificate date
- 02.04.2026
Accreditation scope — test methods (60)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Drinking, bottled drinking, surface, ground, pool, hot, waste and process water | Determination of pH by potentiometry Regulated area: 1 Physical and chemical analyses |
SOP 01A (ČSN ISO 10523) | ||
| 2 | Sludge | Determination of pH by potentiometry Regulated area: 1 Physical and chemical analyses |
SOP 01B (ČSN EN ISO 10390) | ||
| 3 | Drinking, bottled drinking, surface, ground, hot, waste and process water | Determination of conductivity Regulated area: 1 Physical and chemical analyses |
SOP 02 (ČSN EN 27888) | ||
| 4 | Drinking, bottled drinking, surface, ground, hot and process water | Determination of colour by spectrophotometry Regulated area: 1 Physical and chemical analyses |
SOP 03 (ČSN EN ISO 7887) | ||
| 5 | Drinking, bottled drinking, surface, ground, hot, pool and process water | Determination of turbidity by nephelometry Regulated area: 1 Physical and chemical analyses |
SOP 04 (ČSN EN ISO 7027-1) | ||
| 6 | Drinking, surface, ground, pool and hot water | Determination of free and total chlorine by photometry using a Hach commercial analytical kit and combined chlorine by calculation free chlorine total chlorine combined chlorine (calculated) Regulated area: 1 Physical and chemical analyses |
SOP 05 (ČSN EN ISO 7393-2; návod firmy Hach) | ||
| 7 | Drinking, bottled drinking, surface, ground, hot, pool, waste and process water, liquid sludge | Determination of temperature Regulated area: 1 Physical and chemical analyses |
SOP 07 (ČSN 75 7342) | ||
| 8 | Drinking, bottled drinking, surface and ground water | Determination of absorbance at 254 nm (A254) by spectrophotometry Regulated area: 1 Physical and chemical analyses |
SOP 08 (ČSN 75 7360) | ||
| 9 | Drinking, bottled drinking, surface, ground, waste and process water, liquid sludge | Determination of dissolved oxygen and oxygen saturation electrochemically dissolved oxygen oxygen saturation Regulated area: 1 Physical and chemical analyses |
SOP 09 (ČSN EN ISO 5814) | ||
| 10 | Drinking, bottled drinking, surface, ground, hot, waste and process water | Determination of dissolved solids and dissolved inorganic salts by gravimetry dissolved solids dissolved inorganic salts Regulated area: 1 Physical and chemical analyses |
SOP 10 (ČSN 75 7346; ČSN 75 7347) | ||
| 11 | Drinking, bottled drinking, surface, ground, hot, pool, waste and process water | Determination of suspended solids by gravimetry Regulated area: 1 Physical and chemical analyses |
SOP 11 (ČSN EN 872) | ||
| 12 | Drinking, bottled drinking, surface, ground and hot water | Determination of odour and taste, threshold odour and taste number – indicative sensory analysis Regulated area: 1 Physical and chemical analyses |
SOP 12 (ČSN EN 1622; ČSN 75 7340) | ||
| 13 | Drinking, bottled drinking, surface, ground, waste and process water | Determination of acid neutralising capacity (ANC) by titration Regulated area: 1 Physical and chemical analyses |
SOP 13 (ČSN EN ISO 9963-1) | ||
| 14 | Drinking, bottled drinking, surface, ground and pool water | Determination of oxidation-reduction potential by potentiometry Regulated area: 1 Physical and chemical analyses |
SOP 14 (ČSN 75 7367) | ||
| 15 | Drinking, bottled drinking, surface, ground, hot, pool, waste and process water | Determination of chlorides by titration Regulated area: 1 Physical and chemical analyses |
SOP 15 (ČSN ISO 9297) | ||
| 16 | Drinking, bottled drinking, surface, ground, hot, waste and process water | Determination of sulphates by gravimetry Regulated area: 1 Physical and chemical analyses |
SOP 16 (TNV 75 7476) | ||
| 17 | Surface, ground and waste water | Determination of chemical oxygen demand by dichromate (CODCr) by the sealed-tube method, spectrophotometrically using a Merck commercial analytical kit Regulated area: 1 Physical and chemical analyses |
SOP 17 (ČSN ISO 15705; návod firmy Merck) | ||
| 18 | Drinking, surface, ground, waste and process water | Determination of biochemical oxygen demand (BOD5) electrochemically Regulated area: 1 Physical and chemical analyses |
SOP 18 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 19 | Drinking, bottled drinking, surface, ground, hot, pool, waste and process water | Determination of ammonium ions by spectrophotometry, ammonium nitrogen by calculation from measured values ammonium nitrogen (calculated) Regulated area: 1 Physical and chemical analyses |
SOP 19 (ČSN ISO 7150-1) | ||
| 20 | Drinking, bottled drinking, surface, ground, waste and process water | Determination of ammonium ions by titration after distillation, ammonium nitrogen by calculation from measured values ammonium nitrogen (calculated) Regulated area: 1 Physical and chemical analyses |
SOP 20 (ČSN ISO 5664) | ||
| 21 | Drinking, bottled drinking, surface, ground, hot, pool, waste and process water | Determination of nitrates by spectrophotometry, nitrate nitrogen by calculation from measured values nitrate nitrogen (calculated) Regulated area: 1 Physical and chemical analyses |
SOP 21 (ČSN ISO 7890-3) | ||
| 22 | Drinking, bottled drinking, surface, ground, waste and process water | Determination of nitrites by spectrophotometry, nitrite nitrogen by calculation from measured values nitrite nitrogen (calculated) Regulated area: 1 Physical and chemical analyses |
SOP 22 (ČSN EN 26777) | ||
| 23 | Drinking, bottled drinking, surface, ground, hot, waste and process water | Determination of phosphates and total phosphorus by spectrophotometry phosphates total phosphorus Regulated area: 1 Physical and chemical analyses |
SOP 24 (ČSN EN ISO 6878, kap. 4, 7) | ||
| 24 | Drinking, bottled drinking, surface, ground, hot and process water | Determination of calcium by titration Regulated area: 1 Physical and chemical analyses |
SOP 25 (ČSN ISO 6058) | ||
| 25 | Drinking, bottled drinking, surface, ground, hot and process water | Determination of the sum of calcium and magnesium (hardness) by titration and magnesium by calculation sum of calcium and magnesium (hardness) magnesium (calculated) Regulated area: 1 Physical and chemical analyses |
SOP 26 (ČSN ISO 6059; ČSN ISO 6058) | ||
| 26 | Drinking, bottled drinking, surface, ground, pool, waste and process water | Determination of iron by spectrophotometry Regulated area: 1 Physical and chemical analyses |
SOP 27 (ČSN ISO 6332) | ||
| 27 | Drinking, bottled drinking, surface and ground water | Determination of manganese by spectrophotometry Regulated area: 1 Physical and chemical analyses |
SOP 28 (ČSN ISO 6333) | ||
| 28 | Drinking, bottled drinking, surface and ground water | Determination of boron by spectrophotometry Regulated area: 1 Physical and chemical analyses |
SOP 30 (ČSN ISO 9390) | ||
| 29 | Drinking, surface, ground, waste and process water | Determination of chemical oxygen demand by dichromate (CODCr) by titration Regulated area: 1 Physical and chemical analyses |
SOP 31 (ČSN ISO 6060) | ||
| 30 | Surface, ground and waste water | Determination of non-polar extractable substances (NELIR) and extractable substances (ELIR) by IR spectrometry non-polar extractable substances (NELIR) extractable substances (ELIR) Regulated area: 1 Physical and chemical analyses |
SOP 34 (ČSN 75 7505:1998; ČSN 75 7506) | ||
| 31 | Drinking, bottled drinking, surface, ground and waste water | Determination of extractable substances by gravimetry Regulated area: 1 Physical and chemical analyses |
SOP 35 (ČSN 75 7508) | ||
| 32 | Sludge | Determination of dry matter and loss on ignition by gravimetry dry matter loss on ignition Regulated area: 1 Physical and chemical analyses |
SOP 37 (ČSN EN 15934; ČSN EN 15935) | ||
| 33 | Drinking, bottled drinking, surface, ground and process water | Determination of base neutralising capacity (BNC) by titration Regulated area: 1 Physical and chemical analyses |
SOP 44 (ČSN 75 7372) | ||
| 34 | Drinking, bottled drinking, surface and ground water | Determination of humic substances by spectrophotometry Regulated area: 1 Physical and chemical analyses |
SOP 47 (ČSN 75 7536) | ||
| 35 | Drinking, bottled drinking, surface, ground, waste and process water | Determination of total cyanides after distillation by spectrophotometry – using a Merck commercial analytical kit Regulated area: 1 Physical and chemical analyses |
SOP 55 (ČSN 75 7415; návod firmy Merck) | ||
| 36 | Drinking and hot water | Determination of chlorine dioxide by photometry using a Hach commercial analytical kit Regulated area: 1 Physical and chemical analyses |
SOP 57 (návod firmy Hach) | ||
| 37 | Drinking, surface, pool and hot water | Determination of thermotolerant coliform bacteria and Escherichia coli by the membrane filtration method Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 61 (ČSN 75 7835) | ||
| 38 | Drinking, bottled drinking, surface, ground, hot and pool water | Determination of intestinal enterococci by the membrane filtration method Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 62 (ČSN EN ISO 7899-2) | ||
| 39 | Drinking, bottled drinking, surface, ground, pool, hot and process water | Determination of Escherichia coli and coliform bacteria by the membrane filtration method Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 63 (ČSN EN ISO 9308-1) | ||
| 40 | Drinking, bottled drinking, surface, ground, pool, hot and process water | Determination of culturable micro-organisms a) at 22 °C, b) at 36 °C by direct inoculation into a culture medium at 22 °C at 36 °C Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 66 (ČSN EN ISO 6222) | ||
| 41 | Drinking, bottled drinking, pool, hot and process water | Determination of Pseudomonas aeruginosa by the membrane filtration method Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 67 (ČSN EN ISO 16266) | ||
| 42 | Drinking, pool, hot and process water | Determination of Staphylococcus aureus by the membrane filtration method Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 68 (ČSN EN ISO 6888-1) | ||
| 43 | Drinking, bottled drinking and surface water | Determination of Clostridium perfringens (including spores) by the membrane filtration method Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 69 (Vyhláška č. 252/2004 Sb.; Vyhláška č. 70/2018 Sb.) | ||
| 44 | Drinking, bottled drinking, surface and process water | Determination of the microscopic picture – number of organisms, number of living organisms number of organisms number of living organisms Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 70 (ČSN 75 7712) | ||
| 45 | Drinking, bottled drinking, surface and process water | Determination of the microscopic picture – abioseston Regulated area: 2 Microbiological and hydrobiological analyses |
SOP 71 (ČSN 75 7713) | ||
| 46 | Drinking, bottled drinking, surface, ground, hot, pool, waste and process water | Determination of total and dissolved organic carbon (TOC, DOC) after oxidation with IR detection total organic carbon (TOC) dissolved organic carbon (DOC) Regulated area: 3 Special analyses |
SOP 29 (ČSN EN 1484; návod firmy Analytik Jena) | ||
| 47 | Drinking, bottled drinking, surface, ground and waste water | Determination of total bound nitrogen (TNb) after oxidation with electrochemical detection, inorganic and organic nitrogen by calculation total bound nitrogen (TNb) inorganic nitrogen (calculated), organic nitrogen (calculated) Regulated area: 3 Special analyses |
SOP 48 (ČSN EN ISO 20236; návod firmy Analytik Jena) | ||
| 48 | Drinking, bottled drinking, surface, ground, hot, waste and process water | Determination of metals – Cu, Co, Cr, Ni, Cd, Zn, Pb, Fe, Mn, Al – by flame AAS Copper (Cu) Cobalt (Co) Chromium (Cr) Nickel (Ni) Cadmium (Cd) Zinc (Zn) Lead (Pb) Iron (Fe) Manganese (Mn) Aluminium (Al) Regulated area: 3 Special analyses |
SOP 51A (ČSN EN ISO 15587-2; ČSN 75 7385; ČSN ISO 8288; ČSN EN ISO 5961; ČSN EN 1233; ČSN EN ISO 12020; aplikační listy firmy GBC) | ||
| 49 | Sludge | Determination of metals – Cu, Cr, Ni, Zn, Pb by flame AAS Copper (Cu) Chromium (Cr) Nickel (Ni) Zinc (Zn) Lead (Pb) Regulated area: 3 Special analyses |
SOP 51B (ČSN EN ISO 54321; aplikační listy firmy GBC) | ||
| 50 | Drinking, bottled drinking, surface, ground, hot, waste and process water | Determination of metals – As, Se, Sb, Cd, Cr, Ni, Pb, Be, Al by electrothermal AAS Arsenic (As) Selenium (Se) Antimony (Sb) Cadmium (Cd) Chromium (Cr) Nickel (Ni) Lead (Pb) Beryllium (Be) Aluminium (Al) Regulated area: 3 Special analyses |
SOP 52A (ČSN EN ISO 15586; ČSN EN ISO 12020; ČSN EN ISO 5961; ČSN EN 1233; aplikační listy firmy GBC) | ||
| 51 | Sludge | Determination of metals – As, Cd by electrothermal AAS Arsenic (As) Cadmium (Cd) Regulated area: 3 Special analyses |
SOP 52B (ČSN EN ISO 54321; ČSN P CEN/TS 16172:2013; aplikační listy firmy GBC) | ||
| 52 | Drinking, bottled drinking, surface, ground and process water | Determination of sodium and potassium by AES sodium potassium Regulated area: 3 Special analyses |
SOP 53 (ČSN ISO 9964-3; Horáková, Lischke, Grünwald: Chemické a fyzikální metody analýzy vod, Praha 1989) | ||
| 53 | Drinking, bottled drinking, surface, ground, waste and process water | Determination of mercury using an AMA analyser Regulated area: 3 Special analyses |
SOP 54 (ČSN 75 7440; návod firmy Altec) | ||
| 54 | Drinking, bottled drinking, surface, ground, pool and process water | Determination of anions – chlorides, sulphates, nitrates, nitrites, fluorides, phosphates, bromates, chlorites, chlorates by ion chromatography chlorides sulphates nitrates nitrites fluorides phosphates bromates chlorites chlorates Regulated area: 3 Special analyses |
SOP 56 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) | ||
| 55 | Drinking, bottled drinking, surface, ground, pool, hot and process water | Determination of volatile organic compounds (VOC) by gas chromatography (FID, ECD) and sum of trihalomethanes (THM) by calculation chloroethene (vinyl chloride) 1,2-dichloroethane benzene tetrachloroethene trichloroethene trichloromethane (chloroform) tribromomethane (bromoform) dibromochloromethane bromodichloromethane sum of THM: trichloromethane, tribromomethane, dibromochloromethane, bromodichloromethane (calculated) Regulated area: 3 Special analyses |
SOP 59 (ČSN EN ISO 15680) | ||
| 56 | Drinking and hot water | Sampling of drinking water Regulated area: Sampling |
SPP 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055) | ||
| 57 | Waste water | Sampling of waste water (manual sampling, sampling with an automatic sampler) Regulated area: Sampling |
SPP 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315; ČSN EN ISO 19458) | ||
| 58 | Surface water | Sampling of surface water (manual sampling, sampling with an automatic sampler) Regulated area: Sampling |
SPP 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; TNV 75 7055) | ||
| 59 | Pool water | Sampling of pool water Regulated area: Sampling |
SPP 04 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458; TNV 75 7055) | ||
| 60 | Sludge | Sampling of sludge Regulated area: Sampling |
SPP 06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN 16179) | ||
Reference standards (147)
Horáková, Lischke, Grünwald: Chemické a fyzikální metody analýzy vod, Praha 1989
SOP 01A
SOP 01B
SOP 02
SOP 03
SOP 04
SOP 05
SOP 07
SOP 08
SOP 09
SOP 10
SOP 11
SOP 12
SOP 13
SOP 14
SOP 15
SOP 16
SOP 17
SOP 18
SOP 19
SOP 20
SOP 21
SOP 22
SOP 24
SOP 25
SOP 26
SOP 27
SOP 28
SOP 29
SOP 30
SOP 31
SOP 34
SOP 35
SOP 37
SOP 44
SOP 47
SOP 48
SOP 51A
SOP 51B
SOP 52A
SOP 52B
SOP 53
SOP 54
SOP 55
SOP 56
SOP 57
SOP 59
SOP 61
SOP 62
SOP 63
SOP 66
SOP 67
SOP 68
SOP 69
SOP 70
SOP 71
SPP 01
SPP 02
SPP 03
SPP 04
SPP 06
TNV 75 7055
TNV 75 7476
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č. 70/2018 Sb.
aplikační listy firmy GBC
návod firmy Altec
návod firmy Analytik Jena
návod firmy Hach
návod firmy Merck
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7385
ČSN 75 7415
ČSN 75 7440
ČSN 75 7505:1998
ČSN 75 7506
ČSN 75 7508
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN EN 1233
ČSN EN 1484
ČSN EN 15934
ČSN EN 15935
ČSN EN 16179
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 12020
ČSN EN ISO 15061
ČSN EN ISO 15586
ČSN EN ISO 15587-2
ČSN EN ISO 15680
ČSN EN ISO 16266
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 54321
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 5961
ČSN EN ISO 6222
ČSN EN ISO 6878, kap. 4, 7
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 8288
ČSN ISO 9297
ČSN ISO 9390
ČSN ISO 9964-3
ČSN P CEN/TS 16172:2013