🇨🇿 ENVIFORM a.s. PL
Water & wastewaterEnvironmentMaterials & polymersPetrochemistry & fuels
ENVIFORM a.s. is a laboratory accredited by ČIA under number 1371 (Třinec, Czech Republic). Its accreditation scope covers 92 test methods in the following areas: Water & wastewater, Environment, Materials & polymers, Petrochemistry & fuels. Test objects include: Surface, waste and ground water, Bulk materials, Emissions, Solid fuels.
At a glance
- Accreditation number: ČIA 1371
- Methods in scope: 92
- Types of test objects: 31
- City: Třinec, Czech Republic
- Valid until: 04-12-2029
- Accreditation number
- 1371
- Accreditation body
- ČIA
- Address
- Závodní 814, Staré Město, 739 61 Třinec
- City
- Třinec, Czech Republic
- Division
- CENTRUM LABORATORIÓW
- Valid until
- 04-12-2029
What this laboratory tests (31)
- Surface, waste and ground water — 19 methods
- Bulk materials — 15 methods
- Emissions — 15 methods
- Solid fuels — 4 methods
- Working environment — 4 methods
- Aluminium and its alloys — 3 methods
- Steel, cast iron — 3 methods
- Drinking, surface, ground, waste and bathing water — 2 methods
- Drinking, surface, waste and ground water — 2 methods
- Solid fuels, bulk materials — 2 methods
- Working and non-working environment — 2 methods
- Workplace air — 2 methods
- Automated emission measuring systems — 1 method
- Bathing water — 1 method
- Coke — 1 method
- and 16 more
Laboratory sections (7)
- 5.A Laboratory of Chemical and Physical Analyses — 35 methods
- 2. Emission Measurement Laboratory — 16 methods
- 1. Sampling Laboratory — 12 methods
- 5.B Laboratory of Chemical and Physical Analyses — 12 methods
- 3. Laboratory of the Working and Living Environment — 9 methods
- 4.A Quantometry Laboratory — 7 methods
- 4.B Quantometry Laboratory — 1 method
Laboratory locations
- 1. Laboratorium pobierania próbek — Závodní 814, Staré Město
- 2. Laboratorium pomiarów emisji — Závodní 814, Staré Město
- 3. Laboratorium środowiska pracy i środowiska życia — Závodní 814, Staré Město
- 4.A Laboratorium kwantometrii — Průmyslová 1041, Staré Město
- 4.B Laboratorium kwantometrii — Průmyslová 1000 - budova KKO u jižní brány, Staré Město
- 5.A Laboratorium analiz chemicznych i fizycznych — Závodní 814, Staré Město
- 5.B Laboratorium analiz chemicznych i fizycznych — Průmyslová 1041, Staré Město
Certificate information
- Certificate date
- 04.09.2025
Accreditation scope — test methods (92)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| 1. Sampling Laboratory | |||||
| 1 | Drinking, surface, ground, waste and bathing water | Determination of temperature Regulated area: Tests |
SPL-Lv-01 (ČSN 75 7342) | ||
| 2 | Drinking and bathing water | Determination of total and free chlorine by spectrophotometry with a HACH kit and calculation of combined chlorine Regulated area: Tests |
SPL-Lv-02 (návod firmy HACH | ||
| 3 | Drinking, surface, ground and waste water | Determination of electrical conductivity Regulated area: Tests |
SPL-Lv-03 (ČSN EN 27888) | ||
| 4 | Drinking, surface, ground, waste and bathing water | Determination of pH by potentiometry Regulated area: Tests |
SPL-Lv-04 (ČSN ISO 10523) | ||
| 5 | Drinking, ground, surface and bathing water | Determination of ozone by spectrophotometry with a HACH kit Regulated area: Tests |
SPL-Lv-05 (návod firmy HACH) | ||
| 6 | Surface water | Sampling of surface water (manual sampling) Regulated area: Sampling |
SPO-Lv-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14) | ||
| 7 | Waste water | Sampling of waste water (manual sampling, automatic sampler) Regulated area: Sampling |
SPO-Lv-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) | ||
| 8 | Ground water | Sampling of ground water (manual sampling, sampling with a sampling pump) Regulated area: Sampling |
SPO-Lv-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14) | ||
| 9 | Drinking water, hot water | Sampling of drinking water Regulated area: Sampling |
SPO-Lv-04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 10 | Waste and solid materials | Sampling of waste and solid materials Regulated area: Sampling |
SPO-Lv-05 (ČSN EN 14899; Metodický pokyn ke vzorkování odpadů, Věstník MŽP 2008, částka 4) | ||
| 11 | Sludge, sediments and treated biowaste | Sampling of sludge Regulated area: Sampling |
SPO-Lv-06 (ČSN EN 14899; ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
| 12 | Bathing water | Sampling of bathing water Regulated area: Sampling |
SPO-Lv-07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška MZ č. 238/2011 Sb.) | ||
| 2. Emission Measurement Laboratory | |||||
| 13 | Emissions | Determination of the mass concentration of particulate matter (TZL) by gravimetry Regulated area: Tests |
SPL-Le-01 (ČSN EN 13284-1) | ||
| 14 | Emissions | Determination of gas velocity and volume flow rate in ducts Regulated area: Tests |
SPL-Le-02 (ČSN ISO 10780; ČSN EN ISO 16911-1) | ||
| 15 | Emissions | Determination of water vapour content in ducts by the condensation method and a capacitive sensor Regulated area: Tests |
SPL-Le-05 (ČSN EN 14790) | ||
| 16 | Emissions | Determination of the mass concentration of sulphur dioxide, carbon monoxide and nitrogen oxides with an automated analyser – NDIR method Regulated area: Tests |
SPL-Le-06 (ČSN ISO 7935; ČSN EN 15058; ČSN ISO 10849) | ||
| 17 | Emissions | Determination of the mass concentration of gases and vapours by calculation from measured values HCl (hydrogen chloride) HF (hydrogen fluoride) SO2 (sulphur dioxide) Regulated area: Tests |
SPL-Le-07 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN EN 14791) | ||
| 18 | Emissions | Determination of the mass concentration of nitrogen oxides – chemiluminescence method Regulated area: Tests |
SPL-Le-08 (ČSN EN 14792) | ||
| 19 | Emissions | Determination of the total mass concentration of organic substances expressed as TOC with an automated analyser – flame ionisation detection method Regulated area: Tests |
SPL-Le-09 (ČSN EN 12619) | ||
| 20 | Emissions | Determination of the volume concentration of oxygen with an automated analyser – paramagnetic method Regulated area: Tests |
SPL-Le-10 (ČSN EN 14789) | ||
| 21 | Emissions | Determination of the mass concentration of carbon dioxide with an automated analyser – NDIR method Regulated area: Tests |
SPL-Le-10A (ISO 12039) | ||
| 22 | Emissions | Determination of the mass concentration of persistent organic pollutants by calculation from measured values PCDD/PCDF (polychlorinated dibenzodioxins and dibenzofurans) PCB (polychlorinated biphenyls) PAH (polycyclic aromatic hydrocarbons) Regulated area: Tests |
SPL-Le-11 (ČSN EN 1948-1; ČSN EN 1948-4+A1) | ||
| 23 | Emissions | Determination of the mass concentration of heavy metals by calculation from measured values Antimony (Sb) Arsenic (As) Beryllium (Be) Tin (Sn) Chromium (Cr) Cobalt (Co) Cadmium (Cd) Manganese (Mn) Copper (Cu) Nickel (Ni) Lead (Pb) Selenium (Se) Tellurium (Te) Thallium (Tl) Vanadium (V) Zinc (Zn) Mercury (Hg) Regulated area: Tests |
SPL-Le-12 (ČSN EN 14385; ČSN EN 13211; US EPA 29) | ||
| 24 | Automated emission measuring systems | Quality assurance of automated measuring systems Regulated area: Tests |
SPL-Le-14 (ČSN EN 14181, čl. 6.3-6.8 QAL2, čl. 8 AST) | ||
| 25 | Emissions | Sampling of persistent organic pollutants (PCDD/PCDF, PCB, PAH) by the filtration-condensation method; automatic or manual isokinetic control Regulated area: Sampling |
SPO-Le-11 (ČSN EN 1948-1; ČSN EN 1948-4+A1) | ||
| 26 | Emissions | Sampling of heavy metals (Sb, As, Be, Sn, Cd, Cr, Co, Cu, Mn, Ni, Pb, Se, Te, Tl, V, Zn, Hg); automatic or manual isokinetic control Regulated area: Sampling |
SPO-Le-12 (ČSN EN 14385; ČSN EN 13211; ČSN EN 13284-1; US EPA 29) | ||
| 27 | Emissions | Sampling of particulate matter (TZL); automatic or manual isokinetic control Regulated area: Sampling |
SPO-Le-01 (ČSN EN 13284-1) | ||
| 28 | Emissions | Sampling of gases and vapours by absorption into liquid (HCl, HF, SO2) Regulated area: Sampling |
SPO-Le-07 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN EN 14791) | ||
| 3. Laboratory of the Working and Living Environment | |||||
| 29 | Working environment | Determination of dust concentration by gravimetry Regulated area: Tests |
SPL-Lh-01 (NV 361/2007 Sb.; ČSN EN 481; ČSN EN 482; ČSN EN 689+AC) | ||
| 30 | Working environment | Determination of chemical substances by calculation from measured values Regulated area: Tests |
SPL-Lh-02 (NV 361/2007 Sb.; ČSN EN 481; ČSN EN 482; ČSN EN 689+AC) | ||
| 31 | Working environment | Noise measurement Regulated area: Tests |
SPL-Lh-03 (ČSN EN ISO 9612; Věstník MZ ČR 2013, částka 4) | ||
| 32 | Non-working environment | Noise measurement Regulated area: Tests |
SPL-Lh-04 (ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR 2023, částka 14) | ||
| 33 | Working environment | Vibration measurement Regulated area: Tests |
SPL-Lh-05 (ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN ISO 2631-1; ČSN ISO 2631-2; Věstník MZ ČR 2013, částka 4) | ||
| 34 | Working and non-working environment | Lighting measurement Regulated area: Tests |
SPL-Lh-06 (ČSN 36 0011-1; ČSN 36 0011-2; ČSN 36 0011-3; ČSN 36 0011-4; ČSN 73 0580-1; ČSN 36 0020; ČSN EN 12464-1; ČSN EN 12464-2) | ||
| 35 | Working and non-working environment | Measurement of microclimatic conditions ta (°C) – air temperature tg (°C) – globe thermometer temperature rh (%) – relative air humidity va (m.s-1) – air velocity Regulated area: Tests |
SPL-Lh-07 (ČSN EN ISO 7726; ČSN EN ISO 7730; Věstník MZ ČR 2013, částka 8) | ||
| 36 | Workplace air | Sampling of dust, aerosol and mineral fibres by collection on a filter Regulated area: Sampling |
SPO-Lh-01 (NV 361/2007 Sb.; ČSN EN 481; ČSN EN 482; ČSN EN 689+AC) | ||
| 37 | Workplace air | Sampling of gases and vapours by collection on a solid sorbent Regulated area: Sampling |
SPO-Lh-02 (NV 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1) | ||
| 4.A Quantometry Laboratory | |||||
| 38 | Steel, cast iron | Determination of the mass activity of 60Co by scintillation gamma spectrometry Regulated area: Tests |
SPL-Lq-01 (IAEA-TECDOC-855; SKF 11H 1551822, vyd. 4; Vyhláška č. 422/2016 Sb.; Zákon č. 263/2016 Sb.) | ||
| 39 | Steel, cast iron | Determination of oxygen and hydrogen content by IR absorption after fusion in inert gas Oxygen (O) Hydrogen (H) Regulated area: Tests |
SPL-Lq-02 (ASTM E 1019; ČSN EN 10276-2; ČSN 42 0540; SKF 11H 1551218, vyd. 5; ČSN 42 0529) | ||
| 40 | Steel, cast iron | Determination of nitrogen content by the thermal conductivity method after fusion in inert gas Regulated area: Tests |
SPL-Lq-03 (ASTM E 1019; ČSN EN ISO 15351; ČSN EN ISO 10720) | ||
| 41 | Steel, cast iron, iron, ferroalloys | Determination of total carbon and sulphur content by IR detection after combustion in an induction furnace Carbon (C) Sulphur (S) Regulated area: Tests |
SPL-Lq-04 (ASTM E 1019; ČSN EN ISO 15349-2; ČSN EN ISO 15350; ČSN ISO 9556; ČSN ISO 4935; ČSN 42 0541) | ||
| 42 | Steel, cast iron, iron | Determination of element content by vacuum optical emission spectrometry Carbon (C) Manganese (Mn) Silicon (Si) Phosphorus (P) Sulphur (S) Copper (Cu) Chromium (Cr) Nickel (Ni) Aluminium (Al) Aluminium – metallic form (Al_kovová forma) Molybdenum (Mo) Tungsten (W) Vanadium (V) Titanium (Ti) Cobalt (Co) Arsenic (As) Tin (Sn) Boron (B) Calcium (Ca) Niobium (Nb) Lead (Pb) Antimony (Sb) Zirconium (Zr) Zinc (Zn) Bismuth (Bi) Tantalum (Ta) Cerium (Ce) Magnesium (Mg) Nitrogen (N) Regulated area: Tests |
SPL-Lq-05 (ASTM E 415; ASTM E 1086; ASTM E 1999; uživatelský manuál firmy Thermo Fisher Scientific a firmy OBLF) | ||
| 43 | Metallic materials | Determination of element content by X-ray fluorescence spectrometry Carbon (C) Manganese (Mn) Silicon (Si) Phosphorus (P) Sulphur (S) Aluminium (Al) Copper (Cu) Chromium (Cr) Nickel (Ni) Molybdenum (Mo) Tungsten (W) Vanadium (V) Titanium (Ti) Cobalt (Co) Arsenic (As) Tin (Sn) Niobium (Nb) Lead (Pb) Antimony (Sb) Zirconium (Zr) Zinc (Zn) Bismuth (Bi) Iron (Fe) Regulated area: Tests |
SPL-Lq-06-3A (ASTM E 572; ČSN EN 15063-1; ČSN EN 15063-2; HŽ 42 0594; uživatelský manuál firmy Thermo Fisher Scientific) | ||
| 44 | Bulk materials | Determination of element content by X-ray fluorescence spectrometry and calculation of their oxides, carbonates and fluorides (Fe2O3, SiO2, Al2O3, MnO, CaO, CaCO3, MgO, MgCO3, P2O5, TiO2, Na2O, K2O, Cr2O3, CaF2) from measured values Iron (Fe) Silicon (Si) Aluminium (Al) Manganese (Mn) Calcium (Ca) Magnesium (Mg) Phosphorus (P) Sulphur (S) Titanium (Ti) Sodium (Na) Potassium (K) Chromium (Cr) Zinc (Zn) Fluorine (F) Regulated area: Tests |
SPL-Lq-06-3B (ISO 9516-1; HŽ 42 0593; ČSN EN ISO 12677; HŽ 72 2019; ASTM C 1271; uživatelský manuál firmy Thermo Fisher Scientific) | ||
| 4.B Quantometry Laboratory | |||||
| 45 | Steel | Determination of element content by vacuum optical emission spectrometry Carbon (C) Manganese (Mn) Silicon (Si) Phosphorus (P) Sulphur (S) Copper (Cu) Chromium (Cr) Nickel (Ni) Aluminium (Al) Aluminium – metallic form (Al_kovová forma) Molybdenum (Mo) Tungsten (W) Vanadium (V) Titanium (Ti) Cobalt (Co) Arsenic (As) Tin (Sn) Boron (B) Calcium (Ca) Niobium (Nb) Lead (Pb) Antimony (Sb) Zirconium (Zr) Zinc (Zn) Bismuth (Bi) Magnesium (Mg) Nitrogen (N) Regulated area: Tests |
SPL-Lq-10 (ASTM E 415; uživatelský manuál firmy Thermo Fisher Scientific a firmy OBLF) | ||
| 5.A Laboratory of Chemical and Physical Analyses | |||||
| 46 | Solid fuels, bulk materials | Determination of water content by gravimetry Regulated area: Tests |
SPL-Lk-11 (ČSN 44 1377; ČSN ISO 579; ČSN ISO 687; ČSN EN ISO 18134-1; ČSN EN ISO 18134-2; ČSN EN ISO 18134-3; ČSN P CEN/TS 15414-1; ČSN P CEN/TS 15414-2; ČSN EN ISO 21660-3; ČSN ISO 3087; ČSN ISO 7764:1993; ČSN EN 459-2; ČSN EN 14346:2007, Met.A) | ||
| 47 | Solid fuels | Determination of ash content by gravimetry Regulated area: Tests |
SPL-Lk-12 (ČSN ISO 1171; ČSN EN ISO 18122; ČSN EN ISO 21656) | ||
| 48 | Solid fuels | Determination of volatile matter content by gravimetry Regulated area: Tests |
SPL-Lk-13(ČSN ISO 562; ČSN ISO 5071; ČSN EN ISO 18123; ČSN EN ISO 22167) | ||
| 49 | Solid fuels, bulk materials | Determination of total sulphur and carbon content by IR detection Sulphur (S) Carbon (C) Regulated area: Tests |
SPL-Lk-14 (ČSN ISO 19579; ČSN EN ISO 16948; ČSN EN ISO 16994; ČSN EN ISO 21663; ČSN ISO 29541; ČSN 72 2030-10:1992; ČSN 72 2041-19:1992) | ||
| 50 | Solid fuels | Determination of gross calorific value (Qs) by calorimetry, calculation of net calorific value (Qi) and emission factor from measured values calculation of net calorific value (Qi) and emission factor from measured values (calculated) Regulated area: Tests |
SPL-Lk-15 (ČSN ISO 1928; ČSN EN ISO 18125; ČSN EN ISO 21654) | ||
| 51 | Solid fuels | Determination of elements (C, H, N, S) with an analyser with TCD detection Carbon (C) Hydrogen (H) Nitrogen (N) Sulphur (S) Regulated area: Tests |
SPL-Lk-16(ČSN ISO 29541; ČSN EN ISO 16948; ČSN EN ISO 16994; ČSN EN ISO 21663; Uživatelský manuál fy ELEMENTAR) | ||
| 52 | Coke | Determination of the CRI and CSR indices by gravimetry CRI (coke reactivity index) CSR (coke strength after reaction) Regulated area: Tests |
SPL-Lk-17 (ISO 18894; ČSN ISO 18894) | ||
| 53 | Fuel gases | Determination of the composition of fuel gases (CH4, H2, N2, O2, CO2, CO and C2-C6 hydrocarbons) by gas chromatography with TCD and FID detection and calculation of their gross and net calorific values CH4 (methane) H2 (hydrogen) N2 (nitrogen) O2 (oxygen) CO2 (carbon dioxide) CO (carbon monoxide) C2-C6 hydrocarbons calculation of their gross and net calorific values (calculated) Regulated area: Tests |
SPL-Lk-18 (ČSN EN ISO 6974; ČSN EN ISO 6976) | ||
| 54 | Crude coke-oven benzole | Determination of the chemical composition of benzole by gas chromatography with FID detection n-hexane n-heptane n-octane n-nonane benzene toluene o-xylene p-xylene m-xylene ethylbenzene propylbenzene cyclohexane styrene thiophene pyridine indene naphthalene 1- and 2-methylnaphthalenes biphenyl acenaphthene Regulated area: Tests |
SPL-Lk-19 (ČSN 66 2108:1984) | ||
| 55 | Surface, waste and ground water | Determination of C10 – C40 hydrocarbons by gas chromatography with FID detection Regulated area: Tests |
SPL-Lk-20-3A (ČSN EN ISO 9377-2) | ||
| 56 | Surface, waste and ground water | Determination of Hg with a dedicated atomic absorption spectrometer Regulated area: Tests |
SPL-Lk-23-3A (ČSN 75 7440) | ||
| 57 | Bulk materials | Determination of Hg with a dedicated atomic absorption spectrometer Regulated area: Tests |
SPL-Lk-23-3C (ČSN 75 7440) | ||
| 58 | Surface, waste and ground water | Determination of element content (Al, Pb, Ca, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, V, Zn) by inductively coupled plasma optical emission spectrometry Aluminium (Al) Lead (Pb) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Magnesium (Mg) Manganese (Mn) Nickel (Ni) Vanadium (V) Zinc (Zn) Regulated area: Tests |
SPL-Lk-21-3A (ČSN EN ISO 11885) | ||
| 59 | Surface, waste and ground water | Determination of metal content (Na, K) by flame atomic spectrometry and calculation of oxide content from measured values Sodium (Na) Potassium (K) Regulated area: Tests |
SPL-Lk-22-3A (ČSN ISO 9964-1; ČSN ISO 9964-2) | ||
| 60 | Aluminium and its alloys | Determination of metal content (Co, Cr, Cu, Mn, Mg, Ni, Fe, Zn) by inductively coupled plasma optical emission spectrometry Cobalt (Co) Chromium (Cr) Copper (Cu) Manganese (Mn) Magnesium (Mg) Nickel (Ni) Iron (Fe) Zinc (Zn) Regulated area: Tests |
SPL-Lk-21-3B (ČSN EN 14242) | ||
| 61 | Bulk materials | Determination of metal content (Al, Ca, Cd, Cr, Co, Cu, Fe, Mg, Mn, Ni, Sn, Ti, V) by inductively coupled plasma optical emission spectrometry and calculation of oxide content from measured values Aluminium (Al) Calcium (Ca) Cadmium (Cd) Chromium (Cr) Cobalt (Co) Copper (Cu) Iron (Fe) Magnesium (Mg) Manganese (Mn) Nickel (Ni) Tin (Sn) Titanium (Ti) Vanadium (V) Regulated area: Tests |
SPL-Lk-21-3C (ČSN EN ISO 10058-3; ČSN EN ISO 21587-3; ČSN EN ISO 21079-3; ČSN EN ISO 26845; ČSN EN ISO 20565-3) | ||
| 62 | Bulk materials | Determination of metal content (Pb, Na, K and Zn) by flame atomic spectrometry and calculation of oxides from measured values Lead (Pb) Sodium (Na) Potassium (K) Zinc (Zn) Regulated area: Tests |
SPL-Lk-22-3C (ČSN ISO 7969; ČSN EN ISO 10058-3; ČSN 72 0119; ČSN 72 0120; ČSN EN ISO 26845; ČSN EN ISO 20565-3; ČSN EN ISO 21587-3; ČSN EN ISO 21079-3) | ||
| 63 | Surface, waste and ground water | Determination of total phosphorus (Pc) by spectrophotometry and of phosphates (PO43-) by calculation from measured values phosphates (PO43-) by calculation from measured values (calculated) Regulated area: Tests |
SPL-Lk-29 (ČSN EN ISO 6878, kap. 7) | ||
| 64 | Surface, waste and ground water | Determination of N-NH4+ by spectrophotometry and of ammonium ions and total inorganic nitrogen by calculation from measured values ammonium ions and total inorganic nitrogen by calculation from measured values (calculated) Regulated area: Tests |
SPL-Lk-30 (ČSN ISO 7150-1) | ||
| 65 | Surface, waste and ground water | Determination of dissolved substances (RL105) and dissolved inorganic salts (RAS) by gravimetry Regulated area: Tests |
SPL-Lk-31-3A (ČSN 75 7346; ČSN 75 7347) | ||
| 66 | Surface, waste and ground water | Determination of suspended solids by gravimetry Regulated area: Tests |
SPL-Lk-31-3B (ČSN EN 872) | ||
| 67 | Surface, waste and ground water | Determination of COD-Cr by spectrophotometry – HACH commercial analytical kit Regulated area: Tests |
SPL-Lk-32 (ČSN ISO 15705) | ||
| 68 | Surface, waste and ground water | Determination of monohydric phenols by spectrophotometry Regulated area: Tests |
SPL-Lk-33 (ČSN ISO 6439, Met. A) | ||
| 69 | Surface, waste and ground water | Determination of N-NO2- by spectrophotometry and of nitrites by calculation from measured values nitrites by calculation from measured values (calculated) Regulated area: Tests |
SPL-Lk-34 (ČSN EN 26777) | ||
| 70 | Surface, waste and ground water | Determination of N-NO3- by spectrophotometry and of nitrates by calculation from measured values nitrates by calculation from measured values (calculated) Regulated area: Tests |
SPL-Lk-35 (ČSN ISO 7890-3) | ||
| 71 | Surface, waste and ground water | Determination of chlorides by titration Regulated area: Tests |
SPL-Lk-36 (ČSN ISO 9297) | ||
| 72 | Surface, waste and ground water | Determination of total and dissolved iron by spectrophotometry Regulated area: Tests |
SPL-Lk-37 (ČSN ISO 6332) | ||
| 73 | Surface, waste and ground water | Determination of sulphates by gravimetry Regulated area: Tests |
SPL-Lk-38 (TNV 75 7476) | ||
| 74 | Surface, waste and ground water | Determination of extractable substances (EL) by FTIR Regulated area: Tests |
SPL-Lk-39-3A (ČSN 75 7506) | ||
| 75 | Surface, waste and ground water | Determination of non-polar extractable substances (NEL) by FTIR Regulated area: Tests |
SPL-Lk-39-3B (ČSN 75 7505:1998) | ||
| 76 | Surface, waste and ground water | Determination of electrical conductivity Regulated area: Tests |
SPL-Lk-40 (ČSN EN 27888) | ||
| 77 | Surface, waste and ground water | Determination of pH by potentiometry Regulated area: Tests |
SPL-Lk-41 (ČSN ISO 10523) | ||
| 78 | Drinking, surface, waste and ground water | Determination of calcium and of the sum of calcium and magnesium by titration and of magnesium by calculation from measured values magnesium by calculation from measured values (calculated) Regulated area: Tests |
SPL-Lk-44 (ČSN ISO 6058; ČSN ISO 6059) | ||
| 79 | Drinking, surface, waste and ground water | Determination of fluorides, chlorides, nitrites, nitrates, phosphates and sulphates by ion chromatography Regulated area: Tests |
SPL-Lk-45 (ČSN EN ISO 10304-1) | ||
| 80 | Aluminium and its alloys | Determination of Pb and Zn content by flame atomic spectrometry Lead (Pb) Zinc (Zn) Regulated area: Tests |
SPL-Lk-22-3B (ČSN ISO 5194; ČSN ISO 4192) | ||
| 5.B Laboratory of Chemical and Physical Analyses | |||||
| 81 | Bulk materials | Determination of total and metallic iron and FeO by titration and of Fe2O3 by calculation from measured values Fe2O3 (calculated) Regulated area: Tests |
SPL-Lk-25 (ČSN ISO 2597:1993; ČSN 72 2041-10:1992; ČSN 72 2041-12:1992; ČSN 72 0101; ČSN 720110-3; ČSN 72 0111) | ||
| 82 | Bulk materials | Determination of loss on ignition by gravimetry Regulated area: Tests |
SPL-Lk-26 (ČSN 72 1216; ČSN 72 0103; ČSN 44 1855; ČSN EN 459-2) | ||
| 83 | Bulk materials | Determination of SiO2 by gravimetry Regulated area: Tests |
SPL-Lk-27 (ČSN 72 2030-2:1992; ČSN 72 2041-2:1992; ČSN 72 2041-3:1992; ČSN 72 0101; ČSN 72 0105-1; ČSN 72 0105-2; ČSN EN ISO 10058-1; ČSN EN ISO 20565-1; ČSN EN ISO 21587-1; ČSN 72 1216) | ||
| 84 | Bulk materials | Determination of fluorides by potentiometry Regulated area: Tests |
SPL-Lk-28 (ČSN 72 2041-13:1992) | ||
| 85 | Bulk materials | Determination of sulphates by gravimetry and of sulphites and sulphides by calculation from measured values sulphites, sulphides by calculation from measured values (calculated) Regulated area: Tests |
SPL-Lk-46 (ČSN 72 0117; TNV 757476) | ||
| 86 | Bulk materials | Determination of chlorides by titration Regulated area: Tests |
SPL-Lk-47 (ČSN ISO 9297) | ||
| 87 | Bulk materials | Determination of Al2O3 by titration and of Al by calculation from measured values Al (calculated) Regulated area: Tests |
SPL-Lk-48 (ČSN ISO 6830; ČSN 72 0101; ČSN 72 0109-1; ČSN EN ISO 21587-2; ČSN 72 2030-3:1992) | ||
| 88 | Bulk materials | Determination of Cr2O3 by titration and of Cr by calculation from measured values Cr (calculated) Regulated area: Tests |
SPL-Lk-49 (ČSN 44 1606) | ||
| 89 | Bulk materials | Determination of CaO by titration and of Ca by calculation from measured values Ca (calculated) Regulated area: Tests |
SPL-Lk-50 (ČSN 72 0101; ČSN 72 0113-1; ČSN 72 0113-2; ČSN EN ISO 10058-2; ČSN EN 459-2; ČSN 72 1216; ČSN 72 2030-5:1992) | ||
| 90 | Bulk materials | Determination of MgO by titration and of Mg by calculation from measured values Mg (calculated) Regulated area: Tests |
SPL-Lk-51 (ČSN 72 0101; ČSN 72 0114-1; ČSN 72 0114-2; ČSN EN ISO 10058-2; ČSN EN 459-2; ČSN 72 2030-6:1992) | ||
| 91 | Bulk materials | Determination of P by titration and of P2O5 by calculation from measured values P2O5 (calculated) Regulated area: Tests |
SPL-Lk-52 (ČSN 44 1805) | ||
| 92 | Aluminium and its alloys | Determination of Si by gravimetry Regulated area: Tests |
SPL-Lk-53 (ČSN ISO 797) | ||
Reference standards (289)
ASTM C 1271
ASTM E 1019
ASTM E 1086
ASTM E 1999
ASTM E 415
ASTM E 572
HŽ 42 0593
HŽ 42 0594
HŽ 72 2019
IAEA-TECDOC-855
ISO 12039
ISO 18894
ISO 9516-1
Metodický pokyn ke vzorkování odpadů, Věstník MŽP 2008, částka 4
NV 361/2007 Sb.
SKF 11H 1551218, vyd. 5
SKF 11H 1551822, vyd. 4
SPL-Le-01
SPL-Le-02
SPL-Le-05
SPL-Le-06
SPL-Le-07
SPL-Le-08
SPL-Le-09
SPL-Le-10
SPL-Le-10A
SPL-Le-11
SPL-Le-12
SPL-Le-14
SPL-Lh-01
SPL-Lh-02
SPL-Lh-03
SPL-Lh-04
SPL-Lh-05
SPL-Lh-06
SPL-Lh-07
SPL-Lk-11
SPL-Lk-12
SPL-Lk-13
SPL-Lk-14
SPL-Lk-15
SPL-Lk-16
SPL-Lk-17
SPL-Lk-18
SPL-Lk-19
SPL-Lk-20-3A
SPL-Lk-21-3A
SPL-Lk-21-3B
SPL-Lk-21-3C
SPL-Lk-22-3A
SPL-Lk-22-3B
SPL-Lk-22-3C
SPL-Lk-23-3A
SPL-Lk-23-3C
SPL-Lk-25
SPL-Lk-26
SPL-Lk-27
SPL-Lk-28
SPL-Lk-29
SPL-Lk-30
SPL-Lk-31-3A
SPL-Lk-31-3B
SPL-Lk-32
SPL-Lk-33
SPL-Lk-34
SPL-Lk-35
SPL-Lk-36
SPL-Lk-37
SPL-Lk-38
SPL-Lk-39-3A
SPL-Lk-39-3B
SPL-Lk-40
SPL-Lk-41
SPL-Lk-44
SPL-Lk-45
SPL-Lk-46
SPL-Lk-47
SPL-Lk-48
SPL-Lk-49
SPL-Lk-50
SPL-Lk-51
SPL-Lk-52
SPL-Lk-53
SPL-Lq-01
SPL-Lq-02
SPL-Lq-03
SPL-Lq-04
SPL-Lq-05
SPL-Lq-06-3A
SPL-Lq-06-3B
SPL-Lq-10
SPL-Lv-01
SPL-Lv-02
SPL-Lv-03
SPL-Lv-04
SPL-Lv-05
SPO-Le-01
SPO-Le-07
SPO-Le-11
SPO-Le-12
SPO-Lh-01
SPO-Lh-02
SPO-Lv-01
SPO-Lv-02
SPO-Lv-03
SPO-Lv-04
SPO-Lv-05
SPO-Lv-06
SPO-Lv-07
TNV 75 7476
TNV 757476
US EPA 29
Uživatelský manuál fy ELEMENTAR
Vyhláška MZ č. 238/2011 Sb.
Vyhláška č. 422/2016 Sb.
Věstník MZ ČR 2013, částka 4
Věstník MZ ČR 2013, částka 8
Věstník MZ ČR 2023, částka 14
Zákon č. 263/2016 Sb.
návod firmy HACH
uživatelský manuál firmy Thermo Fisher Scientific
uživatelský manuál firmy Thermo Fisher Scientific a firmy OBLF
ČSN 36 0011-1
ČSN 36 0011-2
ČSN 36 0011-3
ČSN 36 0011-4
ČSN 36 0020
ČSN 42 0529
ČSN 42 0540
ČSN 42 0541
ČSN 44 1377
ČSN 44 1606
ČSN 44 1805
ČSN 44 1855
ČSN 66 2108:1984
ČSN 72 0101
ČSN 72 0103
ČSN 72 0105-1
ČSN 72 0105-2
ČSN 72 0109-1
ČSN 72 0111
ČSN 72 0113-1
ČSN 72 0113-2
ČSN 72 0114-1
ČSN 72 0114-2
ČSN 72 0117
ČSN 72 0119
ČSN 72 0120
ČSN 72 1216
ČSN 72 2030-10:1992
ČSN 72 2030-2:1992
ČSN 72 2030-3:1992
ČSN 72 2030-5:1992
ČSN 72 2030-6:1992
ČSN 72 2041-10:1992
ČSN 72 2041-12:1992
ČSN 72 2041-13:1992
ČSN 72 2041-19:1992
ČSN 72 2041-2:1992
ČSN 72 2041-3:1992
ČSN 720110-3
ČSN 73 0580-1
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7440
ČSN 75 7505:1998
ČSN 75 7506
ČSN EN 10276-2
ČSN EN 12464-1
ČSN EN 12464-2
ČSN EN 12619
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 14181, čl. 6.3-6.8 QAL2, čl. 8 AST
ČSN EN 14242
ČSN EN 14346:2007, Met.A
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 14899
ČSN EN 15058
ČSN EN 15063-1
ČSN EN 15063-2
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-4+A1
ČSN EN 26777
ČSN EN 27888
ČSN EN 459-2
ČSN EN 481
ČSN EN 482
ČSN EN 689+AC
ČSN EN 872
ČSN EN ISO 10058-1
ČSN EN ISO 10058-2
ČSN EN ISO 10058-3
ČSN EN ISO 10304-1
ČSN EN ISO 10720
ČSN EN ISO 11885
ČSN EN ISO 12677
ČSN EN ISO 15349-2
ČSN EN ISO 15350
ČSN EN ISO 15351
ČSN EN ISO 16017-1
ČSN EN ISO 16911-1
ČSN EN ISO 16948
ČSN EN ISO 16994
ČSN EN ISO 18122
ČSN EN ISO 18123
ČSN EN ISO 18125
ČSN EN ISO 18134-1
ČSN EN ISO 18134-2
ČSN EN ISO 18134-3
ČSN EN ISO 19458
ČSN EN ISO 20565-1
ČSN EN ISO 20565-3
ČSN EN ISO 21079-3
ČSN EN ISO 21587-1
ČSN EN ISO 21587-2
ČSN EN ISO 21587-3
ČSN EN ISO 21654
ČSN EN ISO 21656
ČSN EN ISO 21660-3
ČSN EN ISO 21663
ČSN EN ISO 22167
ČSN EN ISO 26845
ČSN EN ISO 5349-1
ČSN EN ISO 5349-2
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 6878, kap. 7
ČSN EN ISO 6974
ČSN EN ISO 6976
ČSN EN ISO 7726
ČSN EN ISO 7730
ČSN EN ISO 9377-2
ČSN EN ISO 9612
ČSN ISO 10523
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 1171
ČSN ISO 15705
ČSN ISO 18894
ČSN ISO 1928
ČSN ISO 19579
ČSN ISO 1996-1
ČSN ISO 1996-2
ČSN ISO 2597:1993
ČSN ISO 2631-1
ČSN ISO 2631-2
ČSN ISO 29541
ČSN ISO 3087
ČSN ISO 4192
ČSN ISO 4935
ČSN ISO 5071
ČSN ISO 5194
ČSN ISO 562
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 579
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6439, Met. A
ČSN ISO 6830
ČSN ISO 687
ČSN ISO 7150-1
ČSN ISO 7764:1993
ČSN ISO 7890-3
ČSN ISO 7935
ČSN ISO 7969
ČSN ISO 797
ČSN ISO 9297
ČSN ISO 9556
ČSN ISO 9964-1
ČSN ISO 9964-2
ČSN P CEN/TS 15414-1
ČSN P CEN/TS 15414-2
ČSN P CEN/TS 17340