🇨🇿 ZLINLAB s.r.o. PL

ČIA 1368 • Zlín - Louky, Czech Republic • 20 methods

Environment

ZLINLAB s.r.o. is a laboratory accredited by ČIA under number 1368 (Zlín - Louky, Czech Republic). Its accreditation scope covers 20 test methods in the following areas: Environment. Test objects include: Emissions, Workplace air, Indoor spaces of buildings, Working environment. Most frequently used techniques: NDIR method – non-dispersive infrared spectrometry, chemiluminescence, condensation method.

At a glance

  • Accreditation number: ČIA 1368
  • Methods in scope: 20
  • Types of test objects: 6
  • Techniques used: 8
  • City: Zlín - Louky, Czech Republic
  • Valid until: 02-04-2030
Accreditation number
1368
Accreditation body
ČIA
Address
Pod Šternberkem 306, 763 02 Zlín - Louky
City
Zlín - Louky, Czech Republic
Division
Laboratorium Analiz Środowiska
Valid until
02-04-2030

What this laboratory tests (6)

Analytical techniques used (8)

Certificate information

Certificate date
02.04.2025

Accreditation scope — test methods (20)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Workplace air, solid sorbent, filter Determination of concentration of chemical substances by calculation from measured values
Regulated area: Tests
PN 1/24 (ČSN EN 482; ČSN EN 689+AC; NV č. 361/2007 Sb.)
2 Workplace air Determination of concentration of dust and oil aerosols by gravimetry
Regulated area: Tests
gravimetric method PN 2/19 (ČSN EN 481; ČSN EN 689+AC; NV č. 361/2007 Sb.)
3 Indoor spaces of buildings Measurement of daylighting
Regulated area: Tests
PN 3/19 (ČSN 36 0011-1; ČSN 36 0011-2)
4 Indoor spaces of buildings Measurement of artificial lighting
Regulated area: Tests
PN 3/19 (ČSN 36 0011-1; ČSN 36 0011-3)
5 Working environment Measurement of noise exposure
Regulated area: Tests
PN 4/19 (ČSN EN ISO 9612; Věstník MZ ČR, částka 4/2013)
6 Workplace air Determination of concentration of toluene diisocyanates by spectrometric NDIR analyser
Regulated area: Tests
spectrometric NDIR analyser PN 7/19 (Firemní materiál Zellweger Analytics)
7 Working environment Measurement of microclimatic parameters (temperature, relative humidity, air flow velocity)
Regulated area: Tests
PN 8/19 (ČSN EN ISO 7726; Věstník MZ ČR, částka 8/2013)
8 Non-workplace environment Measurement of noise
Regulated area: Tests
PN 9/19 (ČSN ISO 1996-1; ČSN ISO 1996-2; Věstník MZ ČR, částka 14/2023)
9 Emissions Determination of flow velocity and volume flow rate
Regulated area: Tests
PN 100/19-1 (ČSN ISO 10780)
10 Emissions Determination of gas moisture (condensation method)
Regulated area: Tests
condensation method PN100/19-2 (ČSN EN 14790)
11 Emissions Determination of mass concentration of gaseous pollutants (SO2) by automated analyser (NDIR method – non-dispersive infrared spectrometry)
Regulated area: Tests
NDIR method – non-dispersive infrared spectrometry PN 200/19-2 (ČSN ISO 7935)
12 Emissions Determination of mass concentration of gaseous pollutants (CO) by automated analyser (NDIR method – non-dispersive infrared spectrometry)
Regulated area: Tests
NDIR method – non-dispersive infrared spectrometry PN 200/19-4 (ČSN EN 15058)
13 Emissions Determination of mass concentration of gaseous pollutants (NOx) by automated analyser (chemiluminescence)
Regulated area: Tests
chemiluminescence PN 200/19-3 (ČSN EN 14792)
14 Emissions Determination of oxygen (O2) concentration by automated analyser (paramagnetic method)
Regulated area: Tests
paramagnetic method PN 200/19-5 (ČSN EN 14789)
15 Emissions Determination of total mass concentration of organic substances expressed as total organic carbon (TOC) by automated analyser (FID)
Regulated area: Tests
FID (flame ionisation detector) PN 200/19- 6 (ČSN EN 12619)
16 Emissions Determination of mass concentration of particulate pollutants (gravimetry)
Regulated area: Tests
gravimetry PN 300/19-2 (ČSN EN 13284-1)
17 Emissions Determination of mass concentration of gases and vapours (HCl) by calculation from measured values
Regulated area: Tests
PN 400/19-2 (ČSN EN 1911)
18 Workplace air Sampling of workplace air onto solid sorbent (filter, sampling tube)
Regulated area: Sampling
PN 5/19 (ČSN EN 482; ČSN EN 689+AC; NV č. 361/2007 Sb.)
19 Emissions Sampling of particulate pollutants (isokinetic sampling with automatic isokinetic control)
Regulated area: Sampling
PN 300/19-1 (ČSN EN 13284-1)
20 Emissions Sampling of gases and vapours (HCl) by absorption into liquid
Regulated area: Sampling
PN 400/19-1 (ČSN EN 1911)

Reference standards (43)

Firemní materiál Zellweger Analytics
NV č. 361/2007 Sb.
PN 1/24
PN 100/19-1
PN 2/19
PN 200/19- 6
PN 200/19-2
PN 200/19-3
PN 200/19-4
PN 200/19-5
PN 3/19
PN 300/19-1
PN 300/19-2
PN 4/19
PN 400/19-1
PN 400/19-2
PN 5/19
PN 7/19
PN 8/19
PN 9/19
PN100/19-2
Věstník MZ ČR, částka 14/2023
Věstník MZ ČR, částka 4/2013
Věstník MZ ČR, částka 8/2013
ČSN 36 0011-1
ČSN 36 0011-2
ČSN 36 0011-3
ČSN EN 12619
ČSN EN 13284-1
ČSN EN 14789
ČSN EN 14790
ČSN EN 14792
ČSN EN 15058
ČSN EN 1911
ČSN EN 481
ČSN EN 482
ČSN EN 689+AC
ČSN EN ISO 7726
ČSN EN ISO 9612
ČSN ISO 10780
ČSN ISO 1996-1
ČSN ISO 1996-2
ČSN ISO 7935

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1368