🇨🇿 VÁPENKA VITOŠOV s.r.o. PL
ConstructionMaterials & polymers
VÁPENKA VITOŠOV s.r.o. is a laboratory accredited by ČIA under number 1362 (Hrabová, Czech Republic). Its accreditation scope covers 8 test methods in the following areas: Construction, Materials & polymers. Test objects include: Limestone, lime, hydrate of lime, Lime, Lime, hydrate of lime. Most frequently used techniques: IR analyzer, Titration, AAS flame method.
At a glance
- Accreditation number: ČIA 1362
- Methods in scope: 8
- Types of test objects: 3
- Techniques used: 6
- City: Hrabová, Czech Republic
- Valid until: 13-05-2030
- Accreditation number
- 1362
- Accreditation body
- ČIA
- Address
- č.p. 54, 789 01 Hrabová
- City
- Hrabová, Czech Republic
- Division
- Laboratorium Badawcze Wapna
- Valid until
- 13-05-2030
What this laboratory tests (3)
- Limestone, lime, hydrate of lime — 6 methods
- Lime — 1 method
- Lime, hydrate of lime — 1 method
Analytical techniques used (6)
- IR analyzer — 2 methods
- Titration — 2 methods
- AAS flame method — 1 method
- Air-jet sieving — 1 method
- Gravimetry — 1 method
- Monitoring the temperature change during lime slaking — 1 method
Certificate information
- Certificate date
- 13.05.2025
Accreditation scope — test methods (8)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Limestone, lime, hydrate of lime | Determination of loss on ignition | Gravimetry | SOP 1 | |
| 2 | Limestone, lime, hydrate of lime | Rapid determination of CaO content (total alkalinity) CaCO3+MgCO3 (calculated) (calculated) |
Titration | SOP 2 | |
| 3 | Lime, hydrate of lime | Determination of free lime | Titration | SOP 3 | |
| 4 | Lime | Determination of reactivity | Monitoring the temperature change during lime slaking | SOP 4 (ČSN EN 459-2) | |
| 5 | Limestone, lime, hydrate of lime | Test of particle size distribution | Air-jet sieving | SOP 5 | |
| 6 | Limestone, lime, hydrate of lime | Determination of CO2 and loss on ignition Carbon dioxide (CO2) Loss on ignition |
IR analyzer | SOP 6 | |
| 7 | Limestone, lime, hydrate of lime | Determination of SO3 and CO2 Sulphur trioxide (SO3) Carbon dioxide (CO2) |
IR analyzer | SOP 8 | |
| 8 | Limestone, lime, hydrate of lime | Determination of Fe, Mg, Al, Si Iron (Fe) Magnesium (Mg) Aluminium (Al) Silicon (Si) Fe2O3, MgO, Al2O3, SiO2 (calculated) (calculated) |
AAS flame method | SOP 9 | |
Reference standards (9)
SOP 1
SOP 2
SOP 3
SOP 4
SOP 5
SOP 6
SOP 8
SOP 9
ČSN EN 459-2