{"lab":{"_id":"69ad52a4de79e566650fd3a2","accr_number":"1362","country":"CZ","accr_body":"ČIA","address":"č.p. 54, 789 01 Hrabová","categories":["construction","materials"],"city":"Hrabová","imported_at":"2026-03-08T10:42:44.590Z","methods_count":8,"name":"VÁPENKA VITOŠOV s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1362_219_2025_CS.pdf","1362_219_2025_EN.pdf"],"scope_summary":"Analizy chemiczne i fizyczne wapieni, wapna i wapna hydratyzowanego","search_text":"vápenka vitošov s.r.o. č.p. 54, 789 01 hrabová other","status":"active","updated_at":"2026-03-08T14:52:11.302Z","valid_from":"","valid_until":"13-05-2030","website":"www.vitosov.cz","parsed_at":"2026-09-28T12:00:00.000Z","map_coord":[49.765195,18.270479],"map_geo":"nominatim-street","certificate_date":"13.05.2025","certificate_no":"219/2025","certificate_replaces":"57/2023 z 08.02.2023","en_official":true,"fields_of_testing":[{"codes":"","pl":"Analizy chemiczne i fizyczne wapieni, wapna i wapna hydratyzowanego","en":"Chemical and physical analyzes of limestones, limes and hydrates of lime","zh":"石灰石、石灰和消石灰的化学和物理分析","cs":"Chemické a fyzikální rozbory vápenců, vápen a vápenných hydrátů"}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze Wapna","lab_division_cs":"Zkušební laboratoř vápna","lab_division_en":"Lime Testing Laboratory","lab_division_zh":"石灰检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"SOP","pl":"Standardowa procedura operacyjna","en":"Standard Operating Procedure","zh":"标准操作程序","cs":"Standardní operační postup"},{"abbr":"IR","pl":"podczerwony","en":"infrared","zh":"红外","cs":"infračervený"},{"abbr":"AAS","pl":"absorpcyjny spektrometr atomowy","en":"atomic absorption spectrometer","zh":"原子吸收光谱仪","cs":"atomový absorpční spektrometr"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"17cfb559501ebd66b37c5430f4ae35371c9110bc8b7f233223f8861827880741","source_pdf_url":"https://www.cai.cz/OA/pdf/219_2025_CS.pdf","source_pdf_url_en":"https://www.cai.cz/OA/pdf/219_2025_EN.pdf"},"methods":[{"_id":"05c8434137da50ea476ed234","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"1","test_object":"Wapień, wapno, wapno hydratyzowane","test_object_en":"Limestone, lime, hydrate of lime","test_object_zh":"石灰石、石灰、消石灰","test_object_cs":"Vápenec, vápno, vápenný hydrát","methodology":"Oznaczanie straty prażenia","methodology_en":"Determination of loss on ignition","methodology_zh":"烧失量测定","methodology_cs":"Stanovení ztráty žíháním","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda wagowa","technique_en":"Gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["Metoda wagowa"],"techniques_en":["Gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie straty prażenia\nMetoda wagowa","reference":"SOP 1","norm_bases":["SOP 1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"literatura źródłowa: Zkušební předpisy 1 - Zkušební předpisy německého průmyslu vápna, díl Chemické zkoušky vápna, listopad 1995, část 9.1","note_en":"source literature: Test specifications 1 - Test specifications of the German lime industry, part Chemical tests of lime, November 1995, part 9.1","note_zh":"参考文献：Zkušební předpisy 1 - Zkušební předpisy německého průmyslu vápna, díl Chemické zkoušky vápna, listopad 1995, část 9.1","note_cs":"zdrojová literatura: Zkušební předpisy 1 - Zkušební předpisy německého průmyslu vápna, díl Chemické zkoušky vápna, listopad 1995, část 9.1","search_text":"Wapień, wapno, wapno hydratyzowane Oznaczanie straty prażenia Metoda wagowa Vápenec, vápno, vápenný hydrát Stanovení ztráty žíháním gravimetricky SOP 1 Wapien, wapno, wapno hydratyzowane Oznaczanie straty prazenia Metoda wagowa Vapenec, vapno, vapenny hydrat Stanoveni ztraty zihanim gravimetricky SOP 1","search_en":"Limestone, lime, hydrate of lime Determination of loss on ignition Gravimetry SOP 1","search_zh":"石灰石、石灰、消石灰 烧失量测定 重量法 SOP 1","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"20dda5939feefaec4a2002e8","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"2","test_object":"Wapień, wapno, wapno hydratyzowane","test_object_en":"Limestone, lime, hydrate of lime","test_object_zh":"石灰石、石灰、消石灰","test_object_cs":"Vápenec, vápno, vápenný hydrát","methodology":"Szybkie oznaczanie zawartości CaO (alkaliczność całkowita)","methodology_en":"Rapid determination of CaO content (total alkalinity)","methodology_zh":"CaO含量（总碱度）快速测定","methodology_cs":"Rychlé stanovení obsahu CaO (celková alkalita)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":["CaCO3+MgCO3 (z obliczeń)"],"computed_en":["CaCO3+MgCO3 (calculated)"],"computed_zh":["CaCO3+MgCO3（计算）"],"computed_cs":["stanovení CaCO3+MgCO3 výpočtem z naměřených hodnot"],"activity":"Szybkie oznaczanie zawartości CaO (alkaliczność całkowita)\nMetoda miareczkowa","reference":"SOP 2","norm_bases":["SOP 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"literatura źródłowa: Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část C 01","note_en":"source literature: Test specifications 2 - Test specifications of the German lime industry, part Chemical and physical tests of mortars, November 1995, part C 01","note_zh":"参考文献：Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část C 01","note_cs":"zdrojová literatura: Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část C 01","search_text":"Wapień, wapno, wapno hydratyzowane Szybkie oznaczanie zawartości CaO (alkaliczność całkowita) Metoda miareczkowa CaCO3+MgCO3 (z obliczeń) Vápenec, vápno, vápenný hydrát Rychlé stanovení obsahu CaO (celková alkalita) titračně stanovení CaCO3+MgCO3 výpočtem z naměřených hodnot SOP 2 Wapien, wapno, wapno hydratyzowane Szybkie oznaczanie zawartosci CaO (alkalicznosc calkowita) Metoda miareczkowa CaCO3+MgCO3 (z obliczen) Vapenec, vapno, vapenny hydrat Rychle stanoveni obsahu CaO (celkova alkalita) titracne stanoveni CaCO3+MgCO3 vypoctem z namerenych hodnot SOP 2","search_en":"Limestone, lime, hydrate of lime Rapid determination of CaO content (total alkalinity) Titration CaCO3+MgCO3 (calculated) SOP 2","search_zh":"石灰石、石灰、消石灰 CaO含量（总碱度）快速测定 滴定法 CaCO3+MgCO3（计算） SOP 2","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0617448552de7eaa16970d50","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"3","test_object":"Wapno, wapno hydratyzowane","test_object_en":"Lime, hydrate of lime","test_object_zh":"石灰、消石灰","test_object_cs":"Vápno, vápenný hydrát","methodology":"Oznaczanie wapna wolnego","methodology_en":"Determination of free lime","methodology_zh":"游离石灰测定","methodology_cs":"Stanovení volného vápna","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda miareczkowa","technique_en":"Titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["Metoda miareczkowa"],"techniques_en":["Titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wapna wolnego\nMetoda miareczkowa","reference":"SOP 3","norm_bases":["SOP 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"literatura źródłowa: Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část C 03","note_en":"source literature: Test specifications 2 - Test specifications of the German lime industry, part Chemical and physical tests of mortars, November 1995, part C 03","note_zh":"参考文献：Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část C 03","note_cs":"zdrojová literatura: Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část C 03","search_text":"Wapno, wapno hydratyzowane Oznaczanie wapna wolnego Metoda miareczkowa Vápno, vápenný hydrát Stanovení volného vápna titračně SOP 3 Wapno, wapno hydratyzowane Oznaczanie wapna wolnego Metoda miareczkowa Vapno, vapenny hydrat Stanoveni volneho vapna titracne SOP 3","search_en":"Lime, hydrate of lime Determination of free lime Titration SOP 3","search_zh":"石灰、消石灰 游离石灰测定 滴定法 SOP 3","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2dacd704fe12d0057129c57b","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"4","test_object":"Wapno","test_object_en":"Lime","test_object_zh":"石灰","test_object_cs":"Vápno","methodology":"Oznaczanie reaktywności","methodology_en":"Determination of reactivity","methodology_zh":"活性测定","methodology_cs":"Stanovení reaktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Pomiar zmiany temperatury podczas gaszenia wapna","technique_en":"Monitoring the temperature change during lime slaking","technique_zh":"消化过程温度变化监测法","technique_cs":"sledováním teplotní změny při hašení vápna","techniques":["Pomiar zmiany temperatury podczas gaszenia wapna"],"techniques_en":["Monitoring the temperature change during lime slaking"],"techniques_zh":["消化过程温度变化监测法"],"techniques_cs":["sledováním teplotní změny při hašení vápna"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie reaktywności\nPomiar zmiany temperatury podczas gaszenia wapna","reference":"SOP 4 (ČSN EN 459-2)","norm_bases":["SOP 4","ČSN EN 459-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wapno Oznaczanie reaktywności Pomiar zmiany temperatury podczas gaszenia wapna Vápno Stanovení reaktivity sledováním teplotní změny při hašení vápna SOP 4 (ČSN EN 459-2) Wapno Oznaczanie reaktywnosci Pomiar zmiany temperatury podczas gaszenia wapna Vapno Stanoveni reaktivity sledovanim teplotni zmeny pri haseni vapna SOP 4 (CSN EN 459-2)","search_en":"Lime Determination of reactivity Monitoring the temperature change during lime slaking SOP 4 (ČSN EN 459-2)","search_zh":"石灰 活性测定 消化过程温度变化监测法 SOP 4 (ČSN EN 459-2)","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a02b18e1b411e38431c1ff7","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"5","test_object":"Wapień, wapno, wapno hydratyzowane","test_object_en":"Limestone, lime, hydrate of lime","test_object_zh":"石灰石、石灰、消石灰","test_object_cs":"Vápenec, vápno, vápenný hydrát","methodology":"Badanie uziarnienia","methodology_en":"Test of particle size distribution","methodology_zh":"粒度试验","methodology_cs":"Zkouška zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Przesiewanie strumieniem powietrza","technique_en":"Air-jet sieving","technique_zh":"空气喷射筛分法","technique_cs":"pomocí vzduchového prosévání","techniques":["Przesiewanie strumieniem powietrza"],"techniques_en":["Air-jet sieving"],"techniques_zh":["空气喷射筛分法"],"techniques_cs":["pomocí vzduchového prosévání"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie uziarnienia\nPrzesiewanie strumieniem powietrza","reference":"SOP 5","norm_bases":["SOP 5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"literatura źródłowa: Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část P 02","note_en":"source literature: Test specifications 2 - Test specifications of the German lime industry, part Chemical and physical tests of mortars, November 1995, part P 02","note_zh":"参考文献：Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část P 02","note_cs":"zdrojová literatura: Zkušební předpisy 2 - Zkušební předpisy německého průmyslu vápna, díl Chemické a fyzikální zkoušky maltovin, listopad 1995, část P 02","search_text":"Wapień, wapno, wapno hydratyzowane Badanie uziarnienia Przesiewanie strumieniem powietrza Vápenec, vápno, vápenný hydrát Zkouška zrnitosti pomocí vzduchového prosévání SOP 5 Wapien, wapno, wapno hydratyzowane Badanie uziarnienia Przesiewanie strumieniem powietrza Vapenec, vapno, vapenny hydrat Zkouska zrnitosti pomoci vzduchoveho prosevani SOP 5","search_en":"Limestone, lime, hydrate of lime Test of particle size distribution Air-jet sieving SOP 5","search_zh":"石灰石、石灰、消石灰 粒度试验 空气喷射筛分法 SOP 5","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ffdd8515edf1ea0791c7e58","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"6","test_object":"Wapień, wapno, wapno hydratyzowane","test_object_en":"Limestone, lime, hydrate of lime","test_object_zh":"石灰石、石灰、消石灰","test_object_cs":"Vápenec, vápno, vápenný hydrát","methodology":"Oznaczanie CO2 i straty prażenia","methodology_en":"Determination of CO2 and loss on ignition","methodology_zh":"CO2和烧失量测定","methodology_cs":"Stanovení CO2 a ztráty žíháním","parameters":[{"name":"Ditlenek węgla (CO2)","range":""},{"name":"Strata prażenia","range":""}],"parameters_en":[{"name":"Carbon dioxide (CO2)","range":""},{"name":"Loss on ignition","range":""}],"parameters_zh":[{"name":"二氧化碳（CO2）","range":""},{"name":"烧失量","range":""}],"parameters_cs":[{"name":"CO2","range":""},{"name":"ztráty žíháním","range":""}],"technique":"Analizator IR","technique_en":"IR analyzer","technique_zh":"红外分析仪法","technique_cs":"IR analyzátorem","techniques":["Analizator IR"],"techniques_en":["IR analyzer"],"techniques_zh":["红外分析仪法"],"techniques_cs":["IR analyzátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie CO2 i straty prażenia\nZakres:\nDitlenek węgla (CO2)\nStrata prażenia\nAnalizator IR","reference":"SOP 6","norm_bases":["SOP 6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"literatura źródłowa: Návod k přístroji CW 800, firmy ELTRA Gmbh., vydáno 12/04","note_en":"source literature: Manual of the CW 800 instrument, ELTRA Gmbh., issued 12/04","note_zh":"参考文献：Návod k přístroji CW 800, firmy ELTRA Gmbh., vydáno 12/04","note_cs":"zdrojová literatura: Návod k přístroji CW 800, firmy ELTRA Gmbh., vydáno 12/04","search_text":"Wapień, wapno, wapno hydratyzowane Oznaczanie CO2 i straty prażenia Analizator IR Ditlenek węgla (CO2)  Strata prażenia  Vápenec, vápno, vápenný hydrát Stanovení CO2 a ztráty žíháním IR analyzátorem CO2  ztráty žíháním  SOP 6 Wapien, wapno, wapno hydratyzowane Oznaczanie CO2 i straty prazenia Analizator IR Ditlenek wegla (CO2)  Strata prazenia  Vapenec, vapno, vapenny hydrat Stanoveni CO2 a ztraty zihanim IR analyzatorem CO2  ztraty zihanim  SOP 6","search_en":"Limestone, lime, hydrate of lime Determination of CO2 and loss on ignition IR analyzer Carbon dioxide (CO2)  Loss on ignition  SOP 6","search_zh":"石灰石、石灰、消石灰 CO2和烧失量测定 红外分析仪法 二氧化碳（CO2）  烧失量  SOP 6","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5cbbb95d64a7ea35cf45aeeb","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"7","test_object":"Wapień, wapno, wapno hydratyzowane","test_object_en":"Limestone, lime, hydrate of lime","test_object_zh":"石灰石、石灰、消石灰","test_object_cs":"Vápenec, vápno, vápenný hydrát","methodology":"Oznaczanie SO3 i CO2","methodology_en":"Determination of SO3 and CO2","methodology_zh":"SO3和CO2测定","methodology_cs":"Stanovení SO3 a CO2","parameters":[{"name":"Tritlenek siarki (SO3)","range":""},{"name":"Ditlenek węgla (CO2)","range":""}],"parameters_en":[{"name":"Sulphur trioxide (SO3)","range":""},{"name":"Carbon dioxide (CO2)","range":""}],"parameters_zh":[{"name":"三氧化硫（SO3）","range":""},{"name":"二氧化碳（CO2）","range":""}],"parameters_cs":[{"name":"SO3","range":""},{"name":"CO2","range":""}],"technique":"Analizator IR","technique_en":"IR analyzer","technique_zh":"红外分析仪法","technique_cs":"IR analyzátorem","techniques":["Analizator IR"],"techniques_en":["IR analyzer"],"techniques_zh":["红外分析仪法"],"techniques_cs":["IR analyzátorem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie SO3 i CO2\nZakres:\nTritlenek siarki (SO3)\nDitlenek węgla (CO2)\nAnalizator IR","reference":"SOP 8","norm_bases":["SOP 8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"literatura źródłowa: Návod k přístroji CS 500, firmy ELTRA Gmbh., vydáno 11/04","note_en":"source literature: Manual of the CS 500 instrument, ELTRA Gmbh., issued 11/04","note_zh":"参考文献：Návod k přístroji CS 500, firmy ELTRA Gmbh., vydáno 11/04","note_cs":"zdrojová literatura: Návod k přístroji CS 500, firmy ELTRA Gmbh., vydáno 11/04","search_text":"Wapień, wapno, wapno hydratyzowane Oznaczanie SO3 i CO2 Analizator IR Tritlenek siarki (SO3)  Ditlenek węgla (CO2)  Vápenec, vápno, vápenný hydrát Stanovení SO3 a CO2 IR analyzátorem SO3  CO2  SOP 8 Wapien, wapno, wapno hydratyzowane Oznaczanie SO3 i CO2 Analizator IR Tritlenek siarki (SO3)  Ditlenek wegla (CO2)  Vapenec, vapno, vapenny hydrat Stanoveni SO3 a CO2 IR analyzatorem SO3  CO2  SOP 8","search_en":"Limestone, lime, hydrate of lime Determination of SO3 and CO2 IR analyzer Sulphur trioxide (SO3)  Carbon dioxide (CO2)  SOP 8","search_zh":"石灰石、石灰、消石灰 SO3和CO2测定 红外分析仪法 三氧化硫（SO3）  二氧化碳（CO2）  SOP 8","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"45cc79fe341dc95257071d53","lab_id":"69ad52a4de79e566650fd3a2","country":"CZ","accr_number":"1362","accr_body":"ČIA","row_label":"8","test_object":"Wapień, wapno, wapno hydratyzowane","test_object_en":"Limestone, lime, hydrate of lime","test_object_zh":"石灰石、石灰、消石灰","test_object_cs":"Vápenec, vápno, vápenný hydrát","methodology":"Oznaczanie Fe, Mg, Al, Si","methodology_en":"Determination of Fe, Mg, Al, Si","methodology_zh":"Fe、Mg、Al、Si测定","methodology_cs":"Stanovení Fe, Mg, Al, Si","parameters":[{"name":"Żelazo (Fe)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Glin (Al)","range":""},{"name":"Krzem (Si)","range":""}],"parameters_en":[{"name":"Iron (Fe)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Silicon (Si)","range":""}],"parameters_zh":[{"name":"铁（Fe）","range":""},{"name":"镁（Mg）","range":""},{"name":"铝（Al）","range":""},{"name":"硅（Si）","range":""}],"parameters_cs":[{"name":"Fe","range":""},{"name":"Mg","range":""},{"name":"Al","range":""},{"name":"Si","range":""}],"technique":"Płomieniowa absorpcyjna spektrometria atomowa (FAAS)","technique_en":"AAS flame method","technique_zh":"火焰原子吸收光谱法","technique_cs":"metodou AAS plamenem","techniques":["Płomieniowa absorpcyjna spektrometria atomowa (FAAS)"],"techniques_en":["AAS flame method"],"techniques_zh":["火焰原子吸收光谱法"],"techniques_cs":["metodou AAS plamenem"],"computed":["Fe2O3, MgO, Al2O3, SiO2 (z obliczeń)"],"computed_en":["Fe2O3, MgO, Al2O3, SiO2 (calculated)"],"computed_zh":["Fe2O3、MgO、Al2O3、SiO2（计算）"],"computed_cs":["Fe2O3, MgO, Al2O3, SiO2 výpočtem z naměřených hodnot"],"activity":"Oznaczanie Fe, Mg, Al, Si\nZakres:\nŻelazo (Fe)\nMagnez (Mg)\nGlin (Al)\nKrzem (Si)\nPłomieniowa absorpcyjna spektrometria atomowa (FAAS)","reference":"SOP 9","norm_bases":["SOP 9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":"literatura źródłowa: Návod k přístroji SavantAA 300,GBS , vydáno 05/09","note_en":"source literature: Manual of the SavantAA 300 instrument, GBS, issued 05/09","note_zh":"参考文献：Návod k přístroji SavantAA 300,GBS , vydáno 05/09","note_cs":"zdrojová literatura: Návod k přístroji SavantAA 300,GBS , vydáno 05/09","search_text":"Wapień, wapno, wapno hydratyzowane Oznaczanie Fe, Mg, Al, Si Płomieniowa absorpcyjna spektrometria atomowa (FAAS) Żelazo (Fe)  Magnez (Mg)  Glin (Al)  Krzem (Si)  Fe2O3, MgO, Al2O3, SiO2 (z obliczeń) Vápenec, vápno, vápenný hydrát Stanovení Fe, Mg, Al, Si metodou AAS plamenem Fe  Mg  Al  Si  Fe2O3, MgO, Al2O3, SiO2 výpočtem z naměřených hodnot SOP 9 Wapien, wapno, wapno hydratyzowane Oznaczanie Fe, Mg, Al, Si Plomieniowa absorpcyjna spektrometria atomowa (FAAS) Zelazo (Fe)  Magnez (Mg)  Glin (Al)  Krzem (Si)  Fe2O3, MgO, Al2O3, SiO2 (z obliczen) Vapenec, vapno, vapenny hydrat Stanoveni Fe, Mg, Al, Si metodou AAS plamenem Fe  Mg  Al  Si  Fe2O3, MgO, Al2O3, SiO2 vypoctem z namerenych hodnot SOP 9","search_en":"Limestone, lime, hydrate of lime Determination of Fe, Mg, Al, Si AAS flame method Iron (Fe)  Magnesium (Mg)  Aluminium (Al)  Silicon (Si)  Fe2O3, MgO, Al2O3, SiO2 (calculated) SOP 9","search_zh":"石灰石、石灰、消石灰 Fe、Mg、Al、Si测定 火焰原子吸收光谱法 铁（Fe）  镁（Mg）  铝（Al）  硅（Si）  Fe2O3、MgO、Al2O3、SiO2（计算） SOP 9","categories":["construction","materials"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"CIA-oficjalne","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}