🇨🇿 Vodovody a kanalizace Vyškov,a.s. PL

ČIA 1324 • Vyškov, Czech Republic • 55 methods

Water & wastewaterMicrobiologyEnvironment

Vodovody a kanalizace Vyškov,a.s. is a laboratory accredited by ČIA under number 1324 (Vyškov, Czech Republic). Its accreditation scope covers 55 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking and raw water, Wastewater and surface water, Sludge, Wastewater.

At a glance

  • Accreditation number: ČIA 1324
  • Methods in scope: 55
  • Types of test objects: 7
  • City: Vyškov, Czech Republic
  • Valid until: 15-08-2029
Accreditation number
1324
Accreditation body
ČIA
Address
Brněnská 410/13, Vyškov - Město, 682 01 Vyškov
City
Vyškov, Czech Republic
Division
Dział laboratoriów gospodarki wodnej
Valid until
15-08-2029

What this laboratory tests (7)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
15.08.2024

Accreditation scope — test methods (55)

No. Test object Methodology / Parameters Technique Reference document
Drinking water laboratory
1 Drinking and raw water Determination of pH by potentiometry
Regulated area: Drinking water laboratory – Chemical analysis
SOP 1/LPV (ČSN ISO 10523)
2 Drinking and raw water Determination of electrical conductivity by potentiometry
Regulated area: Drinking water laboratory – Chemical analysis
SOP 2/LPV (ČSN EN 27888)
3 Drinking and raw water Determination of temperature
Regulated area: Drinking water laboratory – Chemical analysis
SOP 4/LPV (ČSN 75 7342)
4 Drinking and raw water Determination of dissolved oxygen by optical oxygen probe
Regulated area: Drinking water laboratory – Chemical analysis
SOP 18/LPV (ČSN ISO 17289)
5 Drinking and raw water Determination of chemical oxygen demand (COD) with potassium permanganate by titration
Regulated area: Drinking water laboratory – Chemical analysis
SOP 5/LPV (ČSN EN ISO 8467)
6 Drinking and raw water Determination of the sum of calcium and magnesium (Ca+Mg) by titrimetric method and of magnesium by calculation from measured values
Regulated area: Drinking water laboratory – Chemical analysis
SOP 6/LPV (ČSN ISO 6059)
7 Drinking and raw water Determination of calcium by EDTA titrimetric method
Regulated area: Drinking water laboratory – Chemical analysis
SOP 7/LPV (ČSN ISO 6058)
8 Drinking and raw water Determination of iron by photometry with 1,10-phenanthroline
Regulated area: Drinking water laboratory – Chemical analysis
SOP 8/LPV (ČSN ISO 6332)
9 Drinking and raw water Determination of manganese by photometry with formaldoxime
Regulated area: Drinking water laboratory – Chemical analysis
SOP 9/LPV (ČSN ISO 6333)
10 Drinking and raw water Determination of ammonium ions by photometry
Regulated area: Drinking water laboratory – Chemical analysis
SOP 10/LPV (ČSN ISO 7150-1)
11 Drinking and raw water Determination of acid neutralising capacity ANC4.5 by titration
Regulated area: Drinking water laboratory – Chemical analysis
SOP 11/LPV (ČSN EN ISO 9963-1)
12 Drinking and raw water Determination of chloride by Mohr's argentometric method
Regulated area: Drinking water laboratory – Chemical analysis
SOP 12/LPV (ČSN ISO 9297)
13 Drinking and raw water Determination of sulphates by titration with lead nitrate
Regulated area: Drinking water laboratory – Chemical analysis
SOP 13/LPV (ČSN 75 7477)
14 Drinking and raw water Determination of nitrite by photometry
Regulated area: Drinking water laboratory – Chemical analysis
SOP 14/LPV (ČSN EN 26777)
15 Drinking and raw water Determination of nitrate by photometry with salicylate
Regulated area: Drinking water laboratory – Chemical analysis
SOP 15/LPV (ČSN ISO 7890-3)
16 Drinking and raw water Determination of phosphate by photometry with ammonium molybdate
Regulated area: Drinking water laboratory – Chemical analysis
SOP 16/LPV (ČSN EN ISO 6878)
17 Drinking and raw water Determination of absorbance by photometry
Regulated area: Drinking water laboratory – Chemical analysis
SOP 17/LPV (ČSN 75 7360)
18 Drinking and raw water Determination of turbidity by nephelometry
Regulated area: Drinking water laboratory – Chemical analysis
SOP 20/LPV (ČSN EN ISO 7027-1)
19 Drinking and raw water Determination of elements (Cu, K, Na, Zn) by AAS – flame technique
Copper (Cu) Potassium (K) Sodium (Na) Zinc (Zn)
Regulated area: Drinking water laboratory – Chemical analysis
SOP 23/LPV (ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN ISO 8288)
20 Wastewater Determination of elements (Cd, Cr, Cu, Ni, Pb, Zn) by AAS – flame technique
Cadmium (Cd) Chromium (Cr) Copper (Cu) Nickel (Ni) Lead (Pb) Zinc (Zn)
Regulated area: Drinking water laboratory – Chemical analysis
SOP 24/LOV (ČSN ISO 8288; ČSN EN ISO 15587)
21 Sludge Determination of elements (Cr, Cu, Ni, Pb, Zn) by AAS – flame technique
Chromium (Cr) Copper (Cu) Nickel (Ni) Lead (Pb) Zinc (Zn)
Regulated area: Drinking water laboratory – Chemical analysis
SOP 25/LOV (ČSN ISO 8288; ČSN EN 13657)
22 Drinking and raw water Determination of elements (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) by AAS – graphite furnace
Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Nickel (Ni) Lead (Pb) Selenium (Se) Antimony (Sb) Vanadium (V)
Regulated area: Drinking water laboratory – Chemical analysis
SOP 26/LPV (ČSN EN ISO 15586)
23 Wastewater Determination of elements (As, Cd) by AAS – graphite furnace
Arsenic (As) Cadmium (Cd)
Regulated area: Drinking water laboratory – Chemical analysis
SOP 27/LOV (ČSN EN ISO 15586; ČSN EN ISO 15587)
24 Sludge Determination of elements (As, Cd) by AAS – graphite furnace
Arsenic (As) Cadmium (Cd)
Regulated area: Drinking water laboratory – Chemical analysis
SOP 28/LOV (ČSN EN ISO 15586; ČSN EN 13657)
25 Drinking water Determination of free and total chlorine with a HACH kit and calculation of combined chlorine
Regulated area: Drinking water laboratory – Chemical analysis
SOP 3/LPV (ČSN EN ISO 7393-2; návod firmy HACH)
26 Drinking and raw water Determination of odour and taste of drinking water by orientation sensory analysis
Regulated area: Drinking water laboratory – Chemical analysis
SOP 27/LPV (ČSN 75 7340; ČSN EN 1622)
27 Drinking and raw water Determination of sulphates by photometry with a Nanocolor commercial analytical kit
Regulated area: Drinking water laboratory – Chemical analysis
SOP 24/LPV (návod firmy BangCo)
28 Drinking and raw water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration method
Regulated area: Drinking water laboratory – Microbiological analysis
ČSN 75 7835
29 Drinking and raw water Determination of coliform bacteria in non-disinfected water by membrane filtration method
Regulated area: Drinking water laboratory – Microbiological analysis
ČSN 75 7837
30 Drinking and raw water Determination of intestinal enterococci by membrane filtration method
Regulated area: Drinking water laboratory – Microbiological analysis
ČSN EN ISO 7899-2
31 Drinking and raw water Determination of Clostridium perfringens microorganisms by membrane filtration method
Regulated area: Drinking water laboratory – Microbiological analysis
SOP 19/LPV (Vyhláška MZ ČR č. 252/2004 Sb., příloha č. 6)
32 Drinking and raw water Determination of colony count at 36 °C and 22 °C by direct inoculation on a culture medium
Regulated area: Drinking water laboratory – Microbiological analysis
ČSN EN ISO 6222
33 Drinking and raw water Determination of Clostridium perfringens by membrane filtration method
Regulated area: Drinking water laboratory – Microbiological analysis
ČSN EN ISO 14189
34 Drinking and raw water Biological analysis – determination of bioseston by microscopy
Regulated area: Drinking water laboratory – Microbiological analysis
ČSN 75 7712
35 Drinking and raw water Biological analysis – determination of abioseston by microscopy
Regulated area: Drinking water laboratory – Microbiological analysis
ČSN 75 7713
36 Drinking and raw water Determination of total count of coliform bacteria and Escherichia coli by the Colilert-18/Quanti-Tray method
Regulated area: Drinking water laboratory – Microbiological analysis
SOP 22/LPV (návod firmy IDEXX; ČSN EN ISO 9308-2)
37 Drinking and raw water Sampling of drinking water and water used for its treatment (manual sampling)
Regulated area: Drinking water laboratory – Sampling
SOP21/LPV (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
Wastewater laboratory
38 Wastewater and surface water Determination of suspended solids by gravimetry
Regulated area: Wastewater laboratory – Tests
ČSN EN 872
39 Wastewater and surface water Determination of total dissolved solids by gravimetry
Regulated area: Wastewater laboratory – Tests
ČSN 75 7346
40 Wastewater and surface water Determination of dissolved inorganic salts (RAS) by gravimetry and of dissolved organic substances by calculation from measured values
Regulated area: Wastewater laboratory – Tests
SOP 8/LOV (ČSN 75 7346; ČSN 75 7347)
41 Wastewater and surface water Determination of BOD5 by electrochemical method
Regulated area: Wastewater laboratory – Tests
SOP 13/LOV (ČSN EN 1899-1; ČSN EN 1899-2)
42 Wastewater and surface water Determination of COD with potassium dichromate by photometry with a HACH commercial analytical kit
Regulated area: Wastewater laboratory – Tests
SOP 1/LOV (ČSN ISO 15705; návod firmy HACH)
43 Wastewater and surface water Determination of total phosphorus by photometry with ammonium molybdate
Regulated area: Wastewater laboratory – Tests
SOP 2/LOV (ČSN EN ISO 6878)
44 Wastewater and surface water Determination of ammonium nitrogen by photometry and of inorganic nitrogen by calculation from measured values
Regulated area: Wastewater laboratory – Tests
SOP 3/LOV (ČSN ISO 7150-1; Vyhláška MŽP č. 328/2018 Sb., částka 159)
45 Wastewater and surface water Determination of nitrite nitrogen by photometry
Regulated area: Wastewater laboratory – Tests
SOP 4/LOV (ČSN EN 26777)
46 Wastewater and surface water Determination of pH by potentiometry
Regulated area: Wastewater laboratory – Tests
ČSN ISO 10523
47 Wastewater, surface water and raw water Determination of AOX content by batch method
Regulated area: Wastewater laboratory – Tests
ČSN EN ISO 9562
48 Wastewater and surface water Determination of nitrate nitrogen with sulfosalicylic acid by photometry
Regulated area: Wastewater laboratory – Tests
SOP 5/LOV (ČSN ISO 7890-3)
49 Wastewater and surface water Determination of total nitrogen after persulphate digestion by photometry with a HACH commercial analytical kit
Regulated area: Wastewater laboratory – Tests
SOP 6/LOV (ČSN EN ISO 11905-1; návod firmy HACH)
50 Sludge Determination of pH by potentiometry
Regulated area: Wastewater laboratory – Tests
SOP 10/LOV (ČSN EN ISO 10390)
51 Sludge Determination of dry matter and water content (total solids) and of loss on ignition (organic solids) by gravimetry
Regulated area: Wastewater laboratory – Tests
SOP 12/LOV (ČSN EN 15 934 metoda A; ČSN EN 15 935)
52 Wastewater and surface water Determination of temperature
Regulated area: Wastewater laboratory – Tests
SOP 11/LOV (ČSN 757342)
53 Surface water Sampling of surface water (manual sampling)
Regulated area: Wastewater laboratory – Sampling
SOP 7/LOV/a (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)
54 Sludge Sampling of sludge (manual sampling)
Regulated area: Wastewater laboratory – Sampling
SOP 9/LOV (ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN 16179; ČSN EN ISO 5667-14; Vyhláška č. 437/2016 Sb.)
55 Wastewater Sampling of wastewater (manual sampling and sampling by automatic sampler)
Regulated area: Wastewater laboratory – Sampling
SOP 7/LOV/b (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)

Reference standards (110)

SOP 1/LOV
SOP 1/LPV
SOP 10/LOV
SOP 10/LPV
SOP 11/LOV
SOP 11/LPV
SOP 12/LOV
SOP 12/LPV
SOP 13/LOV
SOP 13/LPV
SOP 14/LPV
SOP 15/LPV
SOP 16/LPV
SOP 17/LPV
SOP 18/LPV
SOP 19/LPV
SOP 2/LOV
SOP 2/LPV
SOP 20/LPV
SOP 22/LPV
SOP 23/LPV
SOP 24/LOV
SOP 24/LPV
SOP 25/LOV
SOP 26/LPV
SOP 27/LOV
SOP 27/LPV
SOP 28/LOV
SOP 3/LOV
SOP 3/LPV
SOP 4/LOV
SOP 4/LPV
SOP 5/LOV
SOP 5/LPV
SOP 6/LOV
SOP 6/LPV
SOP 7/LOV/a
SOP 7/LOV/b
SOP 7/LPV
SOP 8/LOV
SOP 8/LPV
SOP 9/LOV
SOP 9/LPV
SOP21/LPV
Vyhláška MZ ČR č. 252/2004 Sb., příloha č. 6
Vyhláška MŽP č. 328/2018 Sb., částka 159
Vyhláška č. 437/2016 Sb.
návod firmy BangCo
návod firmy HACH
návod firmy IDEXX
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7477
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN 757342
ČSN EN 13657
ČSN EN 15 934 metoda A
ČSN EN 15 935
ČSN EN 16179
ČSN EN 1622
ČSN EN 1899-1
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10390
ČSN EN ISO 11905-1
ČSN EN ISO 14189
ČSN EN ISO 15586
ČSN EN ISO 15587
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5667-10
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 8288
ČSN ISO 9297
ČSN ISO 9964-1
ČSN ISO 9964-2

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1324