{"lab":{"_id":"69ad52a4de79e566650fd37e","accr_number":"1324","country":"CZ","accr_body":"ČIA","address":"Brněnská 410/13, Vyškov - Město, 682 01 Vyškov","categories":["water","microbiology","environment"],"city":"Vyškov","imported_at":"2026-03-08T10:42:44.590Z","methods_count":55,"name":"Vodovody a kanalizace Vyškov,a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1324_399_2024_CS.pdf","1324_399_2024_EN.pdf"],"scope_summary":"Analizy fizykochemiczne, mikrobiologiczne i biologiczne oraz pobieranie próbek wód pitnych, surowych, ścieków, wód powierzchniowych i osadów ściekowych.","search_text":"vodovody a kanalizace vyškov,a.s. brněnská 410/13, vyškov - město, 682 01 vyškov 1324","status":"active","updated_at":"2026-03-08T14:52:10.640Z","valid_from":"","valid_until":"15-08-2029","website":"www.vakvyskov.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.vakvyskov.cz/kontakty","map_coord":[49.272585,16.990642],"map_geo":"nominatim-street","certificate_date":"15.08.2024","certificate_no":"399/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Analizy fizykochemiczne, mikrobiologiczne i biologiczne oraz pobieranie próbek wód pitnych, surowych, ścieków, wód powierzchniowych i osadów ściekowych.","en":"Physico-chemical, microbiological and biological analyses and sampling of drinking, raw, waste and surface water and sludge.","zh":"饮用水、原水、废水、地表水和污泥的理化、微生物和生物分析及采样。","cs":"Fyzikálně-chemické, mikrobiologické a biologické rozbory a vzorkování pitných, surových, odpadních, povrchových vod a kalů."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Dział laboratoriów gospodarki wodnej","lab_division_cs":"Útvar vodohospodářských laboratoří","lab_division_en":"Water management laboratories department","lab_division_zh":"水务实验室部","lab_locations":[{"code":null,"name":"Vodovody a kanalizace Vyškov,a.s.","street":"Brněnská 410/13, Vyškov - Město","postal_code":"682 01","city":"Vyškov","is_hq":true,"address":"Brněnská 410/13, Vyškov - Město, 682 01 Vyškov","site":"68201|brněnská410/13vyškov-město"},{"code":null,"name":"Laboratorium wód pitnych","street":"ÚV, Lhota č. 171","postal_code":"682 01","city":"Vyškov","is_hq":false,"address":"ÚV, Lhota č. 171, 682 01 Vyškov","site":"68201|úvlhotač171"},{"code":null,"name":"Laboratorium ścieków","street":"ČOV, Kroměřížská 646/10a","postal_code":"682 01","city":"Vyškov Předměstí","is_hq":false,"address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","site":"68201|čovkroměřížská646/10a"}],"lab_locations_en":[{"code":null,"name":"Vodovody a kanalizace Vyškov,a.s.","street":"Brněnská 410/13, Vyškov - Město","postal_code":"682 01","city":"Vyškov","is_hq":true,"address":"Brněnská 410/13, Vyškov - Město, 682 01 Vyškov","site":"68201|brněnská410/13vyškov-město"},{"code":null,"name":"Drinking water laboratory","street":"ÚV, Lhota č. 171","postal_code":"682 01","city":"Vyškov","is_hq":false,"address":"ÚV, Lhota č. 171, 682 01 Vyškov","site":"68201|úvlhotač171"},{"code":null,"name":"Wastewater laboratory","street":"ČOV, Kroměřížská 646/10a","postal_code":"682 01","city":"Vyškov Předměstí","is_hq":false,"address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","site":"68201|čovkroměřížská646/10a"}],"lab_locations_zh":[{"code":null,"name":"Vodovody a kanalizace Vyškov,a.s.","street":"Brněnská 410/13, Vyškov - Město","postal_code":"682 01","city":"Vyškov","is_hq":true,"address":"Brněnská 410/13, Vyškov - Město, 682 01 Vyškov","site":"68201|brněnská410/13vyškov-město"},{"code":null,"name":"饮用水实验室","street":"ÚV, Lhota č. 171","postal_code":"682 01","city":"Vyškov","is_hq":false,"address":"ÚV, Lhota č. 171, 682 01 Vyškov","site":"68201|úvlhotač171"},{"code":null,"name":"废水实验室","street":"ČOV, Kroměřížská 646/10a","postal_code":"682 01","city":"Vyškov Předměstí","is_hq":false,"address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","site":"68201|čovkroměřížská646/10a"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"LOV","pl":"laboratorium ścieków","en":"wastewater laboratory","zh":"废水实验室","cs":"laboratoř odpadních vod"},{"abbr":"LPV","pl":"laboratorium wód pitnych","en":"drinking water laboratory","zh":"饮用水实验室","cs":"laboratoř pitných vod"},{"abbr":"TNV","pl":"branżowa norma techniczna gospodarki wodnej","en":"sectoral technical standard of water management","zh":"水务行业技术标准","cs":"odvětvová technická norma vodního hospodářství"},{"abbr":"BSK5","pl":"biochemiczne zapotrzebowanie tlenu w ciągu 5 dni","en":"biochemical oxygen demand in 5 days","zh":"5日生化需氧量","cs":"biochemická spotřeba kyslíku za 5 dní"},{"abbr":"CHSKCr","pl":"chemiczne zapotrzebowanie tlenu metodą dwuchromianową","en":"chemical oxygen demand by dichromate","zh":"重铬酸盐法化学需氧量","cs":"chemická spotřeba kyslíku dvojchromanem"},{"abbr":"AOX","pl":"adsorbowalne związki chloroorganiczne (organicznie związane halogeny)","en":"adsorbable organically bound halogens","zh":"可吸附有机卤素","cs":"adsorbovatelné organicky vázané halogeny"},{"abbr":"ÚVL","pl":"dział laboratoriów gospodarki wodnej","en":"water management laboratories department","zh":"水务实验室部","cs":"útvar vodohospodářských laboratoří"},{"abbr":"NV","pl":"rozporządzenie rządu","en":"government regulation","zh":"政府条例","cs":"nařízení vlády"},{"abbr":"ÚV","pl":"stacja uzdatniania wody","en":"water treatment plant","zh":"水处理厂","cs":"úpravna vody"},{"abbr":"ČOV","pl":"oczyszczalnia ścieków","en":"wastewater treatment plant","zh":"污水处理厂","cs":"čistírna odpadní vody"},{"abbr":"AAS","pl":"absorpcyjna spektrometria atomowa","en":"atomic absorption spectrometry","zh":"原子吸收光谱法","cs":"atomová absorpční spektrometrie"},{"abbr":"EDTA","pl":"kwas etylenodiaminotetraoctowy","en":"ethylenediaminetetraacetic acid","zh":"乙二胺四乙酸","cs":"kyselina ethylendiaminotetraoctova"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"175195eb976e873d6ae2a3395a324c24cdbc4a651cf112c57c921f2878eb631f","source_pdf_url":"https://www.cai.cz/OA/pdf/P399_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"3d92838694de8c22d2c4afc5","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.1","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP 1/LPV (ČSN ISO 10523)","norm_bases":["SOP 1/LPV","ČSN ISO 10523"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie pH metodą potencjometryczną Pitné a surové vody Stanovení pH potenciometricky SOP 1/LPV (ČSN ISO 10523) Wody pitne i surowe Oznaczanie pH metoda potencjometryczna Pitne a surove vody Stanoveni pH potenciometricky SOP 1/LPV (CSN ISO 10523)","search_en":"Drinking and raw water Determination of pH by potentiometry SOP 1/LPV (ČSN ISO 10523)","search_zh":"饮用水和原水 电位法测定pH SOP 1/LPV (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67338783c2d3578c8227bffe","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.2","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie przewodności elektrycznej właściwej metodą potencjometryczną","methodology_en":"Determination of electrical conductivity by potentiometry","methodology_zh":"电位法测定电导率","methodology_cs":"Stanovení elektrické konduktivity potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej metodą potencjometryczną","reference":"SOP 2/LPV (ČSN EN 27888)","norm_bases":["SOP 2/LPV","ČSN EN 27888"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie przewodności elektrycznej właściwej metodą potencjometryczną Pitné a surové vody Stanovení elektrické konduktivity potenciometricky SOP 2/LPV (ČSN EN 27888) Wody pitne i surowe Oznaczanie przewodnosci elektrycznej wlasciwej metoda potencjometryczna Pitne a surove vody Stanoveni elektricke konduktivity potenciometricky SOP 2/LPV (CSN EN 27888)","search_en":"Drinking and raw water Determination of electrical conductivity by potentiometry SOP 2/LPV (ČSN EN 27888)","search_zh":"饮用水和原水 电位法测定电导率 SOP 2/LPV (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f490fd2747d60112d32349cd","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.3","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度的测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"SOP 4/LPV (ČSN 75 7342)","norm_bases":["SOP 4/LPV","ČSN 75 7342"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie temperatury Pitné a surové vody Stanovení teploty SOP 4/LPV (ČSN 75 7342) Wody pitne i surowe Oznaczanie temperatury Pitne a surove vody Stanoveni teploty SOP 4/LPV (CSN 75 7342)","search_en":"Drinking and raw water Determination of temperature SOP 4/LPV (ČSN 75 7342)","search_zh":"饮用水和原水 温度的测定 SOP 4/LPV (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"93ca2639f463e643327d40fc","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.4","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie tlenu rozpuszczonego optyczną sondą tlenową","methodology_en":"Determination of dissolved oxygen by optical oxygen probe","methodology_zh":"光学溶解氧探头测定溶解氧","methodology_cs":"Stanovení rozpuštěného kyslíku optickou kyslíkovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego optyczną sondą tlenową","reference":"SOP 18/LPV (ČSN ISO 17289)","norm_bases":["SOP 18/LPV","ČSN ISO 17289"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie tlenu rozpuszczonego optyczną sondą tlenową Pitné a surové vody Stanovení rozpuštěného kyslíku optickou kyslíkovou sondou SOP 18/LPV (ČSN ISO 17289) Wody pitne i surowe Oznaczanie tlenu rozpuszczonego optyczna sonda tlenowa Pitne a surove vody Stanoveni rozpusteneho kysliku optickou kyslikovou sondou SOP 18/LPV (CSN ISO 17289)","search_en":"Drinking and raw water Determination of dissolved oxygen by optical oxygen probe SOP 18/LPV (ČSN ISO 17289)","search_zh":"饮用水和原水 光学溶解氧探头测定溶解氧 SOP 18/LPV (ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9480a8890d83d4fa81e1c7c1","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.5","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu (ChZT) nadmanganianem potasu metodą miareczkową","methodology_en":"Determination of chemical oxygen demand (COD) with potassium permanganate by titration","methodology_zh":"高锰酸钾滴定法测定化学需氧量 (CHSK)","methodology_cs":"Stanovení chemické spotřeby kyslíku CHSK manganistanem draselným titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu (ChZT) nadmanganianem potasu metodą miareczkową","reference":"SOP 5/LPV (ČSN EN ISO 8467)","norm_bases":["SOP 5/LPV","ČSN EN ISO 8467"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie chemicznego zapotrzebowania tlenu (ChZT) nadmanganianem potasu metodą miareczkową Pitné a surové vody Stanovení chemické spotřeby kyslíku CHSK manganistanem draselným titračně SOP 5/LPV (ČSN EN ISO 8467) Wody pitne i surowe Oznaczanie chemicznego zapotrzebowania tlenu (ChZT) nadmanganianem potasu metoda miareczkowa Pitne a surove vody Stanoveni chemicke spotreby kysliku CHSK manganistanem draselnym titracne SOP 5/LPV (CSN EN ISO 8467)","search_en":"Drinking and raw water Determination of chemical oxygen demand (COD) with potassium permanganate by titration SOP 5/LPV (ČSN EN ISO 8467)","search_zh":"饮用水和原水 高锰酸钾滴定法测定化学需氧量 (CHSK) SOP 5/LPV (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"56f60a27cf99ec861717464e","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.6","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkową i magnezu obliczeniowo z wartości zmierzonych","methodology_en":"Determination of the sum of calcium and magnesium (Ca+Mg) by titrimetric method and of magnesium by calculation from measured values","methodology_zh":"滴定法测定钙镁总量 (Ca+Mg)，并由测量值计算镁","methodology_cs":"Stanovení sumy vápníku a hořčíku (Ca+Mg) odměrnou metodou a hořčíku výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkową i magnezu obliczeniowo z wartości zmierzonych","reference":"SOP 6/LPV (ČSN ISO 6059)","norm_bases":["SOP 6/LPV","ČSN ISO 6059"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie sumy wapnia i magnezu (Ca+Mg) metodą miareczkową i magnezu obliczeniowo z wartości zmierzonych Pitné a surové vody Stanovení sumy vápníku a hořčíku (Ca+Mg) odměrnou metodou a hořčíku výpočtem z naměřených hodnot SOP 6/LPV (ČSN ISO 6059) Wody pitne i surowe Oznaczanie sumy wapnia i magnezu (Ca+Mg) metoda miareczkowa i magnezu obliczeniowo z wartosci zmierzonych Pitne a surove vody Stanoveni sumy vapniku a horciku (Ca+Mg) odmernou metodou a horciku vypoctem z namerenych hodnot SOP 6/LPV (CSN ISO 6059)","search_en":"Drinking and raw water Determination of the sum of calcium and magnesium (Ca+Mg) by titrimetric method and of magnesium by calculation from measured values SOP 6/LPV (ČSN ISO 6059)","search_zh":"饮用水和原水 滴定法测定钙镁总量 (Ca+Mg)，并由测量值计算镁 SOP 6/LPV (ČSN ISO 6059)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c8170ea99d194fd33f872e7e","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.7","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie wapnia metodą miareczkową z EDTA","methodology_en":"Determination of calcium by EDTA titrimetric method","methodology_zh":"EDTA滴定法测定钙","methodology_cs":"Stanovení vápníku odměrnou metodou s EDTA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wapnia metodą miareczkową z EDTA","reference":"SOP 7/LPV (ČSN ISO 6058)","norm_bases":["SOP 7/LPV","ČSN ISO 6058"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie wapnia metodą miareczkową z EDTA Pitné a surové vody Stanovení vápníku odměrnou metodou s EDTA SOP 7/LPV (ČSN ISO 6058) Wody pitne i surowe Oznaczanie wapnia metoda miareczkowa z EDTA Pitne a surove vody Stanoveni vapniku odmernou metodou s EDTA SOP 7/LPV (CSN ISO 6058)","search_en":"Drinking and raw water Determination of calcium by EDTA titrimetric method SOP 7/LPV (ČSN ISO 6058)","search_zh":"饮用水和原水 EDTA滴定法测定钙 SOP 7/LPV (ČSN ISO 6058)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"52e20d844504d9d710ead64c","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.8","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie żelaza metodą fotometryczną z 1,10-fenantroliną","methodology_en":"Determination of iron by photometry with 1,10-phenanthroline","methodology_zh":"1,10-菲啰啉光度法测定铁","methodology_cs":"Stanovení železa fotometricky s 1,10-fenantrolinem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie żelaza metodą fotometryczną z 1,10-fenantroliną","reference":"SOP 8/LPV (ČSN ISO 6332)","norm_bases":["SOP 8/LPV","ČSN ISO 6332"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie żelaza metodą fotometryczną z 1,10-fenantroliną Pitné a surové vody Stanovení železa fotometricky s 1,10-fenantrolinem SOP 8/LPV (ČSN ISO 6332) Wody pitne i surowe Oznaczanie zelaza metoda fotometryczna z 1,10-fenantrolina Pitne a surove vody Stanoveni zeleza fotometricky s 1,10-fenantrolinem SOP 8/LPV (CSN ISO 6332)","search_en":"Drinking and raw water Determination of iron by photometry with 1,10-phenanthroline SOP 8/LPV (ČSN ISO 6332)","search_zh":"饮用水和原水 1,10-菲啰啉光度法测定铁 SOP 8/LPV (ČSN ISO 6332)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"47c2b70cf5686085df7cde06","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.9","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie manganu metodą fotometryczną z formaldoksymem","methodology_en":"Determination of manganese by photometry with formaldoxime","methodology_zh":"甲醛肟光度法测定锰","methodology_cs":"Stanovení manganu fotometricky s formaldoximem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie manganu metodą fotometryczną z formaldoksymem","reference":"SOP 9/LPV (ČSN ISO 6333)","norm_bases":["SOP 9/LPV","ČSN ISO 6333"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie manganu metodą fotometryczną z formaldoksymem Pitné a surové vody Stanovení manganu fotometricky s formaldoximem SOP 9/LPV (ČSN ISO 6333) Wody pitne i surowe Oznaczanie manganu metoda fotometryczna z formaldoksymem Pitne a surove vody Stanoveni manganu fotometricky s formaldoximem SOP 9/LPV (CSN ISO 6333)","search_en":"Drinking and raw water Determination of manganese by photometry with formaldoxime SOP 9/LPV (ČSN ISO 6333)","search_zh":"饮用水和原水 甲醛肟光度法测定锰 SOP 9/LPV (ČSN ISO 6333)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"12bbfc9f5e2f6859996d3d85","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.10","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie jonów amonowych metodą fotometryczną","methodology_en":"Determination of ammonium ions by photometry","methodology_zh":"光度法测定铵离子","methodology_cs":"Stanovení amonných iontů fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą fotometryczną","reference":"SOP 10/LPV (ČSN ISO 7150-1)","norm_bases":["SOP 10/LPV","ČSN ISO 7150-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie jonów amonowych metodą fotometryczną Pitné a surové vody Stanovení amonných iontů fotometricky SOP 10/LPV (ČSN ISO 7150-1) Wody pitne i surowe Oznaczanie jonow amonowych metoda fotometryczna Pitne a surove vody Stanoveni amonnych iontu fotometricky SOP 10/LPV (CSN ISO 7150-1)","search_en":"Drinking and raw water Determination of ammonium ions by photometry SOP 10/LPV (ČSN ISO 7150-1)","search_zh":"饮用水和原水 光度法测定铵离子 SOP 10/LPV (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3634ac8a5a31e5c92e4bbaa0","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.11","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie zdolności neutralizowania kwasów KNK4,5 metodą miareczkową","methodology_en":"Determination of acid neutralising capacity ANC4.5 by titration","methodology_zh":"滴定法测定酸中和能力 KNK4,5","methodology_cs":"Stanovení kyselinové neutralizační kapacity KNK4,5 titrační metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizowania kwasów KNK4,5 metodą miareczkową","reference":"SOP 11/LPV (ČSN EN ISO 9963-1)","norm_bases":["SOP 11/LPV","ČSN EN ISO 9963-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie zdolności neutralizowania kwasów KNK4,5 metodą miareczkową Pitné a surové vody Stanovení kyselinové neutralizační kapacity KNK4,5 titrační metodou SOP 11/LPV (ČSN EN ISO 9963-1) Wody pitne i surowe Oznaczanie zdolnosci neutralizowania kwasow KNK4,5 metoda miareczkowa Pitne a surove vody Stanoveni kyselinove neutralizacni kapacity KNK4,5 titracni metodou SOP 11/LPV (CSN EN ISO 9963-1)","search_en":"Drinking and raw water Determination of acid neutralising capacity ANC4.5 by titration SOP 11/LPV (ČSN EN ISO 9963-1)","search_zh":"饮用水和原水 滴定法测定酸中和能力 KNK4,5 SOP 11/LPV (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"88f0c55e102701b140a8ee34","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.12","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie chlorków metodą argentometryczną Mohra","methodology_en":"Determination of chloride by Mohr's argentometric method","methodology_zh":"莫尔银量法测定氯化物","methodology_cs":"Stanovení chloridů argentometricky dle Mohra","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą argentometryczną Mohra","reference":"SOP 12/LPV (ČSN ISO 9297)","norm_bases":["SOP 12/LPV","ČSN ISO 9297"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie chlorków metodą argentometryczną Mohra Pitné a surové vody Stanovení chloridů argentometricky dle Mohra SOP 12/LPV (ČSN ISO 9297) Wody pitne i surowe Oznaczanie chlorkow metoda argentometryczna Mohra Pitne a surove vody Stanoveni chloridu argentometricky dle Mohra SOP 12/LPV (CSN ISO 9297)","search_en":"Drinking and raw water Determination of chloride by Mohr's argentometric method SOP 12/LPV (ČSN ISO 9297)","search_zh":"饮用水和原水 莫尔银量法测定氯化物 SOP 12/LPV (ČSN ISO 9297)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f8bb20d373b6d068463257dd","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.13","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie siarczanów metodą miareczkową azotanem ołowiu","methodology_en":"Determination of sulphates by titration with lead nitrate","methodology_zh":"硝酸铅滴定法测定硫酸盐","methodology_cs":"Stanovení síranů titračně dusičnanem olovnatým","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczanów metodą miareczkową azotanem ołowiu","reference":"SOP 13/LPV (ČSN 75 7477)","norm_bases":["SOP 13/LPV","ČSN 75 7477"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie siarczanów metodą miareczkową azotanem ołowiu Pitné a surové vody Stanovení síranů titračně dusičnanem olovnatým SOP 13/LPV (ČSN 75 7477) Wody pitne i surowe Oznaczanie siarczanow metoda miareczkowa azotanem olowiu Pitne a surove vody Stanoveni siranu titracne dusicnanem olovnatym SOP 13/LPV (CSN 75 7477)","search_en":"Drinking and raw water Determination of sulphates by titration with lead nitrate SOP 13/LPV (ČSN 75 7477)","search_zh":"饮用水和原水 硝酸铅滴定法测定硫酸盐 SOP 13/LPV (ČSN 75 7477)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0d2946de32fba57e13dfd5d9","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.14","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie azotynów metodą fotometryczną","methodology_en":"Determination of nitrite by photometry","methodology_zh":"光度法测定亚硝酸盐","methodology_cs":"Stanovení dusitanů fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotynów metodą fotometryczną","reference":"SOP 14/LPV (ČSN EN 26777)","norm_bases":["SOP 14/LPV","ČSN EN 26777"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie azotynów metodą fotometryczną Pitné a surové vody Stanovení dusitanů fotometricky SOP 14/LPV (ČSN EN 26777) Wody pitne i surowe Oznaczanie azotynow metoda fotometryczna Pitne a surove vody Stanoveni dusitanu fotometricky SOP 14/LPV (CSN EN 26777)","search_en":"Drinking and raw water Determination of nitrite by photometry SOP 14/LPV (ČSN EN 26777)","search_zh":"饮用水和原水 光度法测定亚硝酸盐 SOP 14/LPV (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"03e1b4ee6be3a5183c674d56","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.15","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie azotanów metodą fotometryczną z salicylanem","methodology_en":"Determination of nitrate by photometry with salicylate","methodology_zh":"水杨酸盐光度法测定硝酸盐","methodology_cs":"Stanovení dusičnanů fotometricky salicylanem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotanów metodą fotometryczną z salicylanem","reference":"SOP 15/LPV (ČSN ISO 7890-3)","norm_bases":["SOP 15/LPV","ČSN ISO 7890-3"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie azotanów metodą fotometryczną z salicylanem Pitné a surové vody Stanovení dusičnanů fotometricky salicylanem SOP 15/LPV (ČSN ISO 7890-3) Wody pitne i surowe Oznaczanie azotanow metoda fotometryczna z salicylanem Pitne a surove vody Stanoveni dusicnanu fotometricky salicylanem SOP 15/LPV (CSN ISO 7890-3)","search_en":"Drinking and raw water Determination of nitrate by photometry with salicylate SOP 15/LPV (ČSN ISO 7890-3)","search_zh":"饮用水和原水 水杨酸盐光度法测定硝酸盐 SOP 15/LPV (ČSN ISO 7890-3)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25d5c416404728369a3bebc7","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.16","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie fosforanów metodą fotometryczną z molibdenianem amonu","methodology_en":"Determination of phosphate by photometry with ammonium molybdate","methodology_zh":"钼酸铵光度法测定磷酸盐","methodology_cs":"Stanovení fosforečnanů fotometricky s molybdenanem amonným","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforanów metodą fotometryczną z molibdenianem amonu","reference":"SOP 16/LPV (ČSN EN ISO 6878)","norm_bases":["SOP 16/LPV","ČSN EN ISO 6878"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie fosforanów metodą fotometryczną z molibdenianem amonu Pitné a surové vody Stanovení fosforečnanů fotometricky s molybdenanem amonným SOP 16/LPV (ČSN EN ISO 6878) Wody pitne i surowe Oznaczanie fosforanow metoda fotometryczna z molibdenianem amonu Pitne a surove vody Stanoveni fosforecnanu fotometricky s molybdenanem amonnym SOP 16/LPV (CSN EN ISO 6878)","search_en":"Drinking and raw water Determination of phosphate by photometry with ammonium molybdate SOP 16/LPV (ČSN EN ISO 6878)","search_zh":"饮用水和原水 钼酸铵光度法测定磷酸盐 SOP 16/LPV (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a11926434ae230c84aa1b601","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.17","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie absorbancji metodą fotometryczną","methodology_en":"Determination of absorbance by photometry","methodology_zh":"光度法测定吸光度","methodology_cs":"Stanovení absorbance fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie absorbancji metodą fotometryczną","reference":"SOP 17/LPV (ČSN 75 7360)","norm_bases":["SOP 17/LPV","ČSN 75 7360"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie absorbancji metodą fotometryczną Pitné a surové vody Stanovení absorbance fotometricky SOP 17/LPV (ČSN 75 7360) Wody pitne i surowe Oznaczanie absorbancji metoda fotometryczna Pitne a surove vody Stanoveni absorbance fotometricky SOP 17/LPV (CSN 75 7360)","search_en":"Drinking and raw water Determination of absorbance by photometry SOP 17/LPV (ČSN 75 7360)","search_zh":"饮用水和原水 光度法测定吸光度 SOP 17/LPV (ČSN 75 7360)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"486cdb5d3a883c3616076594","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.18","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity by nephelometry","methodology_zh":"浊度法测定浊度","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną","reference":"SOP 20/LPV (ČSN EN ISO 7027-1)","norm_bases":["SOP 20/LPV","ČSN EN ISO 7027-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie mętności metodą nefelometryczną Pitné a surové vody Stanovení zákalu nefelometricky SOP 20/LPV (ČSN EN ISO 7027-1) Wody pitne i surowe Oznaczanie metnosci metoda nefelometryczna Pitne a surove vody Stanoveni zakalu nefelometricky SOP 20/LPV (CSN EN ISO 7027-1)","search_en":"Drinking and raw water Determination of turbidity by nephelometry SOP 20/LPV (ČSN EN ISO 7027-1)","search_zh":"饮用水和原水 浊度法测定浊度 SOP 20/LPV (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7494ca8b1dc367ad94d9f299","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.19","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie pierwiastków (Cu, K, Na, Zn) metodą AAS – technika płomieniowa","methodology_en":"Determination of elements (Cu, K, Na, Zn) by AAS – flame technique","methodology_zh":"原子吸收光谱法（火焰技术）测定元素 (Cu, K, Na, Zn)","methodology_cs":"Stanovení prvků (Cu, K, Na, Zn) metodou AAS – plamenová technika","parameters":[{"name":"Miedź (Cu)","range":""},{"name":"Potas (K)","range":""},{"name":"Sód (Na)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Copper (Cu)","range":""},{"name":"Potassium (K)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铜（Cu）","range":""},{"name":"钾（K）","range":""},{"name":"钠（Na）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Cu","range":""},{"name":"K","range":""},{"name":"Na","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków (Cu, K, Na, Zn) metodą AAS – technika płomieniowa\nZakres:\nMiedź (Cu)\nPotas (K)\nSód (Na)\nCynk (Zn)","reference":"SOP 23/LPV (ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN ISO 8288)","norm_bases":["SOP 23/LPV","ČSN ISO 9964-1","ČSN ISO 9964-2","ČSN ISO 8288"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie pierwiastków (Cu, K, Na, Zn) metodą AAS – technika płomieniowa Miedź (Cu)  Potas (K)  Sód (Na)  Cynk (Zn)  Pitné a surové vody Stanovení prvků (Cu, K, Na, Zn) metodou AAS – plamenová technika Cu  K  Na  Zn  SOP 23/LPV (ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN ISO 8288) Wody pitne i surowe Oznaczanie pierwiastkow (Cu, K, Na, Zn) metoda AAS – technika plomieniowa Miedz (Cu)  Potas (K)  Sod (Na)  Cynk (Zn)  Pitne a surove vody Stanoveni prvku (Cu, K, Na, Zn) metodou AAS – plamenova technika Cu  K  Na  Zn  SOP 23/LPV (CSN ISO 9964-1; CSN ISO 9964-2; CSN ISO 8288)","search_en":"Drinking and raw water Determination of elements (Cu, K, Na, Zn) by AAS – flame technique Copper (Cu)  Potassium (K)  Sodium (Na)  Zinc (Zn)  SOP 23/LPV (ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN ISO 8288)","search_zh":"饮用水和原水 原子吸收光谱法（火焰技术）测定元素 (Cu, K, Na, Zn) 铜（Cu）  钾（K）  钠（Na）  锌（Zn）  SOP 23/LPV (ČSN ISO 9964-1; ČSN ISO 9964-2; ČSN ISO 8288)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f09ec75b2cbe47ed96e55f90","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.20","test_object":"Ścieki","test_object_en":"Wastewater","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie pierwiastków (Cd, Cr, Cu, Ni, Pb, Zn) metodą AAS – technika płomieniowa","methodology_en":"Determination of elements (Cd, Cr, Cu, Ni, Pb, Zn) by AAS – flame technique","methodology_zh":"原子吸收光谱法（火焰技术）测定元素 (Cd, Cr, Cu, Ni, Pb, Zn)","methodology_cs":"Stanovení prvků (Cd, Cr, Cu, Ni, Pb, Zn) metodou AAS –plamenová technika","parameters":[{"name":"Kadm (Cd)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Cadmium (Cd)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"镉（Cd）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Cd","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków (Cd, Cr, Cu, Ni, Pb, Zn) metodą AAS – technika płomieniowa\nZakres:\nKadm (Cd)\nChrom (Cr)\nMiedź (Cu)\nNikiel (Ni)\nOłów (Pb)\nCynk (Zn)","reference":"SOP 24/LOV (ČSN ISO 8288; ČSN EN ISO 15587)","norm_bases":["SOP 24/LOV","ČSN ISO 8288","ČSN EN ISO 15587"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie pierwiastków (Cd, Cr, Cu, Ni, Pb, Zn) metodą AAS – technika płomieniowa Kadm (Cd)  Chrom (Cr)  Miedź (Cu)  Nikiel (Ni)  Ołów (Pb)  Cynk (Zn)  Odpadní vody Stanovení prvků (Cd, Cr, Cu, Ni, Pb, Zn) metodou AAS –plamenová technika Cd  Cr  Cu  Ni  Pb  Zn  SOP 24/LOV (ČSN ISO 8288; ČSN EN ISO 15587) Scieki Oznaczanie pierwiastkow (Cd, Cr, Cu, Ni, Pb, Zn) metoda AAS – technika plomieniowa Kadm (Cd)  Chrom (Cr)  Miedz (Cu)  Nikiel (Ni)  Olow (Pb)  Cynk (Zn)  Odpadni vody Stanoveni prvku (Cd, Cr, Cu, Ni, Pb, Zn) metodou AAS –plamenova technika Cd  Cr  Cu  Ni  Pb  Zn  SOP 24/LOV (CSN ISO 8288; CSN EN ISO 15587)","search_en":"Wastewater Determination of elements (Cd, Cr, Cu, Ni, Pb, Zn) by AAS – flame technique Cadmium (Cd)  Chromium (Cr)  Copper (Cu)  Nickel (Ni)  Lead (Pb)  Zinc (Zn)  SOP 24/LOV (ČSN ISO 8288; ČSN EN ISO 15587)","search_zh":"废水 原子吸收光谱法（火焰技术）测定元素 (Cd, Cr, Cu, Ni, Pb, Zn) 镉（Cd）  铬（Cr）  铜（Cu）  镍（Ni）  铅（Pb）  锌（Zn）  SOP 24/LOV (ČSN ISO 8288; ČSN EN ISO 15587)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c1908b52870b0de6833416b","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.21","test_object":"Osady ściekowe","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Oznaczanie pierwiastków (Cr, Cu, Ni, Pb, Zn) metodą AAS – technika płomieniowa","methodology_en":"Determination of elements (Cr, Cu, Ni, Pb, Zn) by AAS – flame technique","methodology_zh":"原子吸收光谱法（火焰技术）测定元素 (Cr, Cu, Ni, Pb, Zn)","methodology_cs":"Stanovení prvků (Cr, Cu, Ni, Pb, Zn) metodou AAS–plamenová technika","parameters":[{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków (Cr, Cu, Ni, Pb, Zn) metodą AAS – technika płomieniowa\nZakres:\nChrom (Cr)\nMiedź (Cu)\nNikiel (Ni)\nOłów (Pb)\nCynk (Zn)","reference":"SOP 25/LOV (ČSN ISO 8288; ČSN EN 13657)","norm_bases":["SOP 25/LOV","ČSN ISO 8288","ČSN EN 13657"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady ściekowe Oznaczanie pierwiastków (Cr, Cu, Ni, Pb, Zn) metodą AAS – technika płomieniowa Chrom (Cr)  Miedź (Cu)  Nikiel (Ni)  Ołów (Pb)  Cynk (Zn)  Kaly Stanovení prvků (Cr, Cu, Ni, Pb, Zn) metodou AAS–plamenová technika Cr  Cu  Ni  Pb  Zn  SOP 25/LOV (ČSN ISO 8288; ČSN EN 13657) Osady sciekowe Oznaczanie pierwiastkow (Cr, Cu, Ni, Pb, Zn) metoda AAS – technika plomieniowa Chrom (Cr)  Miedz (Cu)  Nikiel (Ni)  Olow (Pb)  Cynk (Zn)  Kaly Stanoveni prvku (Cr, Cu, Ni, Pb, Zn) metodou AAS–plamenova technika Cr  Cu  Ni  Pb  Zn  SOP 25/LOV (CSN ISO 8288; CSN EN 13657)","search_en":"Sludge Determination of elements (Cr, Cu, Ni, Pb, Zn) by AAS – flame technique Chromium (Cr)  Copper (Cu)  Nickel (Ni)  Lead (Pb)  Zinc (Zn)  SOP 25/LOV (ČSN ISO 8288; ČSN EN 13657)","search_zh":"污泥 原子吸收光谱法（火焰技术）测定元素 (Cr, Cu, Ni, Pb, Zn) 铬（Cr）  铜（Cu）  镍（Ni）  铅（Pb）  锌（Zn）  SOP 25/LOV (ČSN ISO 8288; ČSN EN 13657)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9ab7e3c8fa7026b3b1f239aa","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.22","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie pierwiastków (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) metodą AAS – kuweta grafitowa","methodology_en":"Determination of elements (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) by AAS – graphite furnace","methodology_zh":"原子吸收光谱法（石墨管）测定元素 (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V)","methodology_cs":"Stanovení prvků (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) metodou AAS–grafitová kyveta","parameters":[{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Wanad (V)","range":""}],"parameters_en":[{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Vanadium (V)","range":""}],"parameters_zh":[{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"硒（Se）","range":""},{"name":"锑（Sb）","range":""},{"name":"钒（V）","range":""}],"parameters_cs":[{"name":"Al","range":""},{"name":"As","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Se","range":""},{"name":"Sb","range":""},{"name":"V","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) metodą AAS – kuweta grafitowa\nZakres:\nGlin (Al)\nArsen (As)\nBar (Ba)\nBeryl (Be)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nNikiel (Ni)\nOłów (Pb)\nSelen (Se)\nAntymon (Sb)\nWanad (V)","reference":"SOP 26/LPV (ČSN EN ISO 15586)","norm_bases":["SOP 26/LPV","ČSN EN ISO 15586"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie pierwiastków (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) metodą AAS – kuweta grafitowa Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Nikiel (Ni)  Ołów (Pb)  Selen (Se)  Antymon (Sb)  Wanad (V)  Pitné a surové vody Stanovení prvků (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) metodou AAS–grafitová kyveta Al  As  Ba  Be  Cd  Co  Cr  Ni  Pb  Se  Sb  V  SOP 26/LPV (ČSN EN ISO 15586) Wody pitne i surowe Oznaczanie pierwiastkow (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) metoda AAS – kuweta grafitowa Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Nikiel (Ni)  Olow (Pb)  Selen (Se)  Antymon (Sb)  Wanad (V)  Pitne a surove vody Stanoveni prvku (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) metodou AAS–grafitova kyveta Al  As  Ba  Be  Cd  Co  Cr  Ni  Pb  Se  Sb  V  SOP 26/LPV (CSN EN ISO 15586)","search_en":"Drinking and raw water Determination of elements (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) by AAS – graphite furnace Aluminium (Al)  Arsenic (As)  Barium (Ba)  Beryllium (Be)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Nickel (Ni)  Lead (Pb)  Selenium (Se)  Antimony (Sb)  Vanadium (V)  SOP 26/LPV (ČSN EN ISO 15586)","search_zh":"饮用水和原水 原子吸收光谱法（石墨管）测定元素 (Al, As, Ba, Be, Cd, Co, Cr, Ni, Pb, Se, Sb, V) 铝（Al）  砷（As）  钡（Ba）  铍（Be）  镉（Cd）  钴（Co）  铬（Cr）  镍（Ni）  铅（Pb）  硒（Se）  锑（Sb）  钒（V）  SOP 26/LPV (ČSN EN ISO 15586)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dae0192921737ddc41e9028b","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.23","test_object":"Ścieki","test_object_en":"Wastewater","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Oznaczanie pierwiastków (As, Cd) metodą AAS – kuweta grafitowa","methodology_en":"Determination of elements (As, Cd) by AAS – graphite furnace","methodology_zh":"原子吸收光谱法（石墨管）测定元素 (As, Cd)","methodology_cs":"Stanovení prvků (As, Cd) metodou AAS–grafitová kyveta","parameters":[{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Cd","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków (As, Cd) metodą AAS – kuweta grafitowa\nZakres:\nArsen (As)\nKadm (Cd)","reference":"SOP 27/LOV (ČSN EN ISO 15586; ČSN EN ISO 15587)","norm_bases":["SOP 27/LOV","ČSN EN ISO 15586","ČSN EN ISO 15587"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Oznaczanie pierwiastków (As, Cd) metodą AAS – kuweta grafitowa Arsen (As)  Kadm (Cd)  Odpadní vody Stanovení prvků (As, Cd) metodou AAS–grafitová kyveta As  Cd  SOP 27/LOV (ČSN EN ISO 15586; ČSN EN ISO 15587) Scieki Oznaczanie pierwiastkow (As, Cd) metoda AAS – kuweta grafitowa Arsen (As)  Kadm (Cd)  Odpadni vody Stanoveni prvku (As, Cd) metodou AAS–grafitova kyveta As  Cd  SOP 27/LOV (CSN EN ISO 15586; CSN EN ISO 15587)","search_en":"Wastewater Determination of elements (As, Cd) by AAS – graphite furnace Arsenic (As)  Cadmium (Cd)  SOP 27/LOV (ČSN EN ISO 15586; ČSN EN ISO 15587)","search_zh":"废水 原子吸收光谱法（石墨管）测定元素 (As, Cd) 砷（As）  镉（Cd）  SOP 27/LOV (ČSN EN ISO 15586; ČSN EN ISO 15587)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6f8420c7d33a3d721d77b52c","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.24","test_object":"Osady ściekowe","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Oznaczanie pierwiastków (As, Cd) metodą AAS – kuweta grafitowa","methodology_en":"Determination of elements (As, Cd) by AAS – graphite furnace","methodology_zh":"原子吸收光谱法（石墨管）测定元素 (As, Cd)","methodology_cs":"Stanovení prvků (As, Cd) metodou AAS–grafitová kyveta","parameters":[{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Cd","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków (As, Cd) metodą AAS – kuweta grafitowa\nZakres:\nArsen (As)\nKadm (Cd)","reference":"SOP 28/LOV (ČSN EN ISO 15586; ČSN EN 13657)","norm_bases":["SOP 28/LOV","ČSN EN ISO 15586","ČSN EN 13657"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady ściekowe Oznaczanie pierwiastków (As, Cd) metodą AAS – kuweta grafitowa Arsen (As)  Kadm (Cd)  Kaly Stanovení prvků (As, Cd) metodou AAS–grafitová kyveta As  Cd  SOP 28/LOV (ČSN EN ISO 15586; ČSN EN 13657) Osady sciekowe Oznaczanie pierwiastkow (As, Cd) metoda AAS – kuweta grafitowa Arsen (As)  Kadm (Cd)  Kaly Stanoveni prvku (As, Cd) metodou AAS–grafitova kyveta As  Cd  SOP 28/LOV (CSN EN ISO 15586; CSN EN 13657)","search_en":"Sludge Determination of elements (As, Cd) by AAS – graphite furnace Arsenic (As)  Cadmium (Cd)  SOP 28/LOV (ČSN EN ISO 15586; ČSN EN 13657)","search_zh":"污泥 原子吸收光谱法（石墨管）测定元素 (As, Cd) 砷（As）  镉（Cd）  SOP 28/LOV (ČSN EN ISO 15586; ČSN EN 13657)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be3722a481576c13e8843f53","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.25","test_object":"Wody pitne","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Pitné vody","methodology":"Oznaczanie chloru wolnego i całkowitego zestawem HACH oraz obliczenie chloru związanego","methodology_en":"Determination of free and total chlorine with a HACH kit and calculation of combined chlorine","methodology_zh":"使用HACH试剂盒测定游离氯和总氯，并计算结合氯","methodology_cs":"Stanovení volného a celkového chloru setem HACH a dopočet vázaného chloru","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chloru wolnego i całkowitego zestawem HACH oraz obliczenie chloru związanego","reference":"SOP 3/LPV (ČSN EN ISO 7393-2; návod firmy HACH)","norm_bases":["SOP 3/LPV","ČSN EN ISO 7393-2","návod firmy HACH"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne Oznaczanie chloru wolnego i całkowitego zestawem HACH oraz obliczenie chloru związanego Pitné vody Stanovení volného a celkového chloru setem HACH a dopočet vázaného chloru SOP 3/LPV (ČSN EN ISO 7393-2; návod firmy HACH) Wody pitne Oznaczanie chloru wolnego i calkowitego zestawem HACH oraz obliczenie chloru zwiazanego Pitne vody Stanoveni volneho a celkoveho chloru setem HACH a dopocet vazaneho chloru SOP 3/LPV (CSN EN ISO 7393-2; navod firmy HACH)","search_en":"Drinking water Determination of free and total chlorine with a HACH kit and calculation of combined chlorine SOP 3/LPV (ČSN EN ISO 7393-2; návod firmy HACH)","search_zh":"饮用水 使用HACH试剂盒测定游离氯和总氯，并计算结合氯 SOP 3/LPV (ČSN EN ISO 7393-2; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3eda561726a80704a7b7fc00","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.26","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie zapachu i smaku wody pitnej metodą orientacyjnej analizy sensorycznej","methodology_en":"Determination of odour and taste of drinking water by orientation sensory analysis","methodology_zh":"感官定性分析法测定饮用水的气味和味道","methodology_cs":"Stanovení pachu a chuti pitné vody metodou orientační senzorické analýzy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zapachu i smaku wody pitnej metodą orientacyjnej analizy sensorycznej","reference":"SOP 27/LPV (ČSN 75 7340; ČSN EN 1622)","norm_bases":["SOP 27/LPV","ČSN 75 7340","ČSN EN 1622"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie zapachu i smaku wody pitnej metodą orientacyjnej analizy sensorycznej Pitné a surové vody Stanovení pachu a chuti pitné vody metodou orientační senzorické analýzy SOP 27/LPV (ČSN 75 7340; ČSN EN 1622) Wody pitne i surowe Oznaczanie zapachu i smaku wody pitnej metoda orientacyjnej analizy sensorycznej Pitne a surove vody Stanoveni pachu a chuti pitne vody metodou orientacni senzoricke analyzy SOP 27/LPV (CSN 75 7340; CSN EN 1622)","search_en":"Drinking and raw water Determination of odour and taste of drinking water by orientation sensory analysis SOP 27/LPV (ČSN 75 7340; ČSN EN 1622)","search_zh":"饮用水和原水 感官定性分析法测定饮用水的气味和味道 SOP 27/LPV (ČSN 75 7340; ČSN EN 1622)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b93fdaf7cbbd19a55e244a14","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1.27","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie siarczanów metodą fotometryczną komercyjnym zestawem analitycznym Nanocolor","methodology_en":"Determination of sulphates by photometry with a Nanocolor commercial analytical kit","methodology_zh":"使用Nanocolor商品分析试剂盒光度法测定硫酸盐","methodology_cs":"Stanovení síranů fotometricky, analytickou komerční soupravou Nanocolor","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie siarczanów metodą fotometryczną komercyjnym zestawem analitycznym Nanocolor","reference":"SOP 24/LPV (návod firmy BangCo)","norm_bases":["SOP 24/LPV","návod firmy BangCo"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza chemiczna","regulatory_area_en":"Drinking water laboratory – Chemical analysis","regulatory_area_zh":"饮用水实验室 – 化学分析","regulatory_area_cs":"Laboratoř pitných vod – Chemický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie siarczanów metodą fotometryczną komercyjnym zestawem analitycznym Nanocolor Pitné a surové vody Stanovení síranů fotometricky, analytickou komerční soupravou Nanocolor SOP 24/LPV (návod firmy BangCo) Wody pitne i surowe Oznaczanie siarczanow metoda fotometryczna komercyjnym zestawem analitycznym Nanocolor Pitne a surove vody Stanoveni siranu fotometricky, analytickou komercni soupravou Nanocolor SOP 24/LPV (navod firmy BangCo)","search_en":"Drinking and raw water Determination of sulphates by photometry with a Nanocolor commercial analytical kit SOP 24/LPV (návod firmy BangCo)","search_zh":"饮用水和原水 使用Nanocolor商品分析试剂盒光度法测定硫酸盐 SOP 24/LPV (návod firmy BangCo)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b27dbbd6cb81c0456a6bcec9","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.1","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą filtracji membranowej","methodology_en":"Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration method","methodology_zh":"膜过滤法测定耐热大肠菌群和大肠埃希氏菌","methodology_cs":"Stanovení termotolerantních koliformních bakterií a Escherichia coli metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą filtracji membranowej","reference":"ČSN 75 7835","norm_bases":["ČSN 75 7835"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metodą filtracji membranowej Pitné a surové vody Stanovení termotolerantních koliformních bakterií a Escherichia coli metodou membránových filtrů ČSN 75 7835 Wody pitne i surowe Oznaczanie termotolerancyjnych bakterii grupy coli i Escherichia coli metoda filtracji membranowej Pitne a surove vody Stanoveni termotolerantnich koliformnich bakterii a Escherichia coli metodou membranovych filtru CSN 75 7835","search_en":"Drinking and raw water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration method ČSN 75 7835","search_zh":"饮用水和原水 膜过滤法测定耐热大肠菌群和大肠埃希氏菌 ČSN 75 7835","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bb1162fee9ebbbd190a707cf","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.2","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą filtracji membranowej","methodology_en":"Determination of coliform bacteria in non-disinfected water by membrane filtration method","methodology_zh":"膜过滤法测定未消毒水中的大肠菌群","methodology_cs":"Stanovení koliformních bakterií v nedesinfikovaných vodách metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą filtracji membranowej","reference":"ČSN 75 7837","norm_bases":["ČSN 75 7837"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metodą filtracji membranowej Pitné a surové vody Stanovení koliformních bakterií v nedesinfikovaných vodách metodou membránových filtrů ČSN 75 7837 Wody pitne i surowe Oznaczanie bakterii grupy coli w wodach niedezynfekowanych metoda filtracji membranowej Pitne a surove vody Stanoveni koliformnich bakterii v nedesinfikovanych vodach metodou membranovych filtru CSN 75 7837","search_en":"Drinking and raw water Determination of coliform bacteria in non-disinfected water by membrane filtration method ČSN 75 7837","search_zh":"饮用水和原水 膜过滤法测定未消毒水中的大肠菌群 ČSN 75 7837","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"83a70b06162c121b38c25a52","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.3","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","methodology_en":"Determination of intestinal enterococci by membrane filtration method","methodology_zh":"膜过滤法测定肠球菌","methodology_cs":"Stanovení intestinálních enterokoků metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","reference":"ČSN EN ISO 7899-2","norm_bases":["ČSN EN ISO 7899-2"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie enterokoków jelitowych metodą filtracji membranowej Pitné a surové vody Stanovení intestinálních enterokoků metodou membránových filtrů ČSN EN ISO 7899-2 Wody pitne i surowe Oznaczanie enterokokow jelitowych metoda filtracji membranowej Pitne a surove vody Stanoveni intestinalnich enterokoku metodou membranovych filtru CSN EN ISO 7899-2","search_en":"Drinking and raw water Determination of intestinal enterococci by membrane filtration method ČSN EN ISO 7899-2","search_zh":"饮用水和原水 膜过滤法测定肠球菌 ČSN EN ISO 7899-2","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"72727b5b43aaa3ac352614fd","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.4","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie drobnoustrojów Clostridium perfringens metodą filtracji membranowej","methodology_en":"Determination of Clostridium perfringens microorganisms by membrane filtration method","methodology_zh":"膜过滤法测定产气荚膜梭菌","methodology_cs":"Stanovení mikroorganismů Clostridium perfringens metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie drobnoustrojów Clostridium perfringens metodą filtracji membranowej","reference":"SOP 19/LPV (Vyhláška MZ ČR č. 252/2004 Sb., příloha č. 6)","norm_bases":["SOP 19/LPV","Vyhláška MZ ČR č. 252/2004 Sb., příloha č. 6"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie drobnoustrojów Clostridium perfringens metodą filtracji membranowej Pitné a surové vody Stanovení mikroorganismů Clostridium perfringens metodou membránových filtrů SOP 19/LPV (Vyhláška MZ ČR č. 252/2004 Sb., příloha č. 6) Wody pitne i surowe Oznaczanie drobnoustrojow Clostridium perfringens metoda filtracji membranowej Pitne a surove vody Stanoveni mikroorganismu Clostridium perfringens metodou membranovych filtru SOP 19/LPV (Vyhlaska MZ CR c. 252/2004 Sb., priloha c. 6)","search_en":"Drinking and raw water Determination of Clostridium perfringens microorganisms by membrane filtration method SOP 19/LPV (Vyhláška MZ ČR č. 252/2004 Sb., příloha č. 6)","search_zh":"饮用水和原水 膜过滤法测定产气荚膜梭菌 SOP 19/LPV (Vyhláška MZ ČR č. 252/2004 Sb., příloha č. 6)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43bd8a4d30452410ca2a4c76","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.5","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie liczby kolonii w 36 °C i 22 °C metodą bezpośredniego posiewu na podłoże hodowlane","methodology_en":"Determination of colony count at 36 °C and 22 °C by direct inoculation on a culture medium","methodology_zh":"直接接种培养基法测定36 °C和22 °C菌落数","methodology_cs":"Stanovení počtu kolonií při 36 °C a 22 °C metodou přímého výsevu na kultivační medium","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby kolonii w 36 °C i 22 °C metodą bezpośredniego posiewu na podłoże hodowlane","reference":"ČSN EN ISO 6222","norm_bases":["ČSN EN ISO 6222"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie liczby kolonii w 36 °C i 22 °C metodą bezpośredniego posiewu na podłoże hodowlane Pitné a surové vody Stanovení počtu kolonií při 36 °C a 22 °C metodou přímého výsevu na kultivační medium ČSN EN ISO 6222 Wody pitne i surowe Oznaczanie liczby kolonii w 36 °C i 22 °C metoda bezposredniego posiewu na podloze hodowlane Pitne a surove vody Stanoveni poctu kolonii pri 36 °C a 22 °C metodou primeho vysevu na kultivacni medium CSN EN ISO 6222","search_en":"Drinking and raw water Determination of colony count at 36 °C and 22 °C by direct inoculation on a culture medium ČSN EN ISO 6222","search_zh":"饮用水和原水 直接接种培养基法测定36 °C和22 °C菌落数 ČSN EN ISO 6222","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"80eaf60cb256ef3961af5b9a","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.6","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie Clostridium perfringens metodą filtracji membranowej","methodology_en":"Determination of Clostridium perfringens by membrane filtration method","methodology_zh":"膜过滤法测定产气荚膜梭菌","methodology_cs":"Stanovení Clostridium perfringens metodou membránových filtrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Clostridium perfringens metodą filtracji membranowej","reference":"ČSN EN ISO 14189","norm_bases":["ČSN EN ISO 14189"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie Clostridium perfringens metodą filtracji membranowej Pitné a surové vody Stanovení Clostridium perfringens metodou membránových filtrů ČSN EN ISO 14189 Wody pitne i surowe Oznaczanie Clostridium perfringens metoda filtracji membranowej Pitne a surove vody Stanoveni Clostridium perfringens metodou membranovych filtru CSN EN ISO 14189","search_en":"Drinking and raw water Determination of Clostridium perfringens by membrane filtration method ČSN EN ISO 14189","search_zh":"饮用水和原水 膜过滤法测定产气荚膜梭菌 ČSN EN ISO 14189","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a554250e4aabee59bf38db34","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.7","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Analiza biologiczna – oznaczanie biosestonu metodą mikroskopową","methodology_en":"Biological analysis – determination of bioseston by microscopy","methodology_zh":"生物分析——显微镜法测定生物悬浮物","methodology_cs":"Biologický rozbor – Stanovení biosestonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Analiza biologiczna – oznaczanie biosestonu metodą mikroskopową","reference":"ČSN 75 7712","norm_bases":["ČSN 75 7712"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Analiza biologiczna – oznaczanie biosestonu metodą mikroskopową Pitné a surové vody Biologický rozbor – Stanovení biosestonu mikroskopicky ČSN 75 7712 Wody pitne i surowe Analiza biologiczna – oznaczanie biosestonu metoda mikroskopowa Pitne a surove vody Biologicky rozbor – Stanoveni biosestonu mikroskopicky CSN 75 7712","search_en":"Drinking and raw water Biological analysis – determination of bioseston by microscopy ČSN 75 7712","search_zh":"饮用水和原水 生物分析——显微镜法测定生物悬浮物 ČSN 75 7712","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"06476655c997ff22b9b25092","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.8","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Analiza biologiczna – oznaczanie abiosestonu metodą mikroskopową","methodology_en":"Biological analysis – determination of abioseston by microscopy","methodology_zh":"生物分析——显微镜法测定非生物悬浮物","methodology_cs":"Biologický rozbor – Stanovení abiosestonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Analiza biologiczna – oznaczanie abiosestonu metodą mikroskopową","reference":"ČSN 75 7713","norm_bases":["ČSN 75 7713"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Analiza biologiczna – oznaczanie abiosestonu metodą mikroskopową Pitné a surové vody Biologický rozbor – Stanovení abiosestonu mikroskopicky ČSN 75 7713 Wody pitne i surowe Analiza biologiczna – oznaczanie abiosestonu metoda mikroskopowa Pitne a surove vody Biologicky rozbor – Stanoveni abiosestonu mikroskopicky CSN 75 7713","search_en":"Drinking and raw water Biological analysis – determination of abioseston by microscopy ČSN 75 7713","search_zh":"饮用水和原水 生物分析——显微镜法测定非生物悬浮物 ČSN 75 7713","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a1e9b45172390912e27451b0","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2.9","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Oznaczanie ogólnej liczby bakterii grupy coli i Escherichia coli metodą Colilert-18/Quanti-Tray","methodology_en":"Determination of total count of coliform bacteria and Escherichia coli by the Colilert-18/Quanti-Tray method","methodology_zh":"Colilert-18/Quanti-Tray法测定大肠菌群总数和大肠埃希氏菌","methodology_cs":"Stanovení celkového počtu koliformních bakterií a Esherichia coli metodou Colilert – 18/Quanti-Tray","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnej liczby bakterii grupy coli i Escherichia coli metodą Colilert-18/Quanti-Tray","reference":"SOP 22/LPV (návod firmy IDEXX; ČSN EN ISO 9308-2)","norm_bases":["SOP 22/LPV","návod firmy IDEXX","ČSN EN ISO 9308-2"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Analiza mikrobiologiczna","regulatory_area_en":"Drinking water laboratory – Microbiological analysis","regulatory_area_zh":"饮用水实验室 – 微生物分析","regulatory_area_cs":"Laboratoř pitných vod – Mikrobiologický rozbor","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Oznaczanie ogólnej liczby bakterii grupy coli i Escherichia coli metodą Colilert-18/Quanti-Tray Pitné a surové vody Stanovení celkového počtu koliformních bakterií a Esherichia coli metodou Colilert – 18/Quanti-Tray SOP 22/LPV (návod firmy IDEXX; ČSN EN ISO 9308-2) Wody pitne i surowe Oznaczanie ogolnej liczby bakterii grupy coli i Escherichia coli metoda Colilert-18/Quanti-Tray Pitne a surove vody Stanoveni celkoveho poctu koliformnich bakterii a Esherichia coli metodou Colilert – 18/Quanti-Tray SOP 22/LPV (navod firmy IDEXX; CSN EN ISO 9308-2)","search_en":"Drinking and raw water Determination of total count of coliform bacteria and Escherichia coli by the Colilert-18/Quanti-Tray method SOP 22/LPV (návod firmy IDEXX; ČSN EN ISO 9308-2)","search_zh":"饮用水和原水 Colilert-18/Quanti-Tray法测定大肠菌群总数和大肠埃希氏菌 SOP 22/LPV (návod firmy IDEXX; ČSN EN ISO 9308-2)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"143d943e126da95bdc2ec28a","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1","test_object":"Wody pitne i surowe","test_object_en":"Drinking and raw water","test_object_zh":"饮用水和原水","test_object_cs":"Pitné a surové vody","methodology":"Pobieranie próbek wód pitnych i wód wykorzystywanych do ich uzdatniania (pobieranie ręczne)","methodology_en":"Sampling of drinking water and water used for its treatment (manual sampling)","methodology_zh":"饮用水及其处理用水的采样（人工采样）","methodology_cs":"Odběr pitných vod a vod používaných k jejich úpravě (manuální odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód pitnych i wód wykorzystywanych do ich uzdatniania (pobieranie ręczne)","reference":"SOP21/LPV (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)","norm_bases":["SOP21/LPV","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN ISO 5667-5","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14","ČSN EN ISO 5667-16","ČSN EN ISO 19458"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking water laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"ÚV, Lhota č. 171, 682 01 Vyškov","regulatory_area":"Laboratorium wód pitnych – Pobieranie próbek","regulatory_area_en":"Drinking water laboratory – Sampling","regulatory_area_zh":"饮用水实验室 – 采样","regulatory_area_cs":"Laboratoř pitných vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody pitne i surowe Pobieranie próbek wód pitnych i wód wykorzystywanych do ich uzdatniania (pobieranie ręczne) Pitné a surové vody Odběr pitných vod a vod používaných k jejich úpravě (manuální odběr) SOP21/LPV (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) Wody pitne i surowe Pobieranie probek wod pitnych i wod wykorzystywanych do ich uzdatniania (pobieranie reczne) Pitne a surove vody Odber pitnych vod a vod pouzivanych k jejich uprave (manualni odber) SOP21/LPV (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN ISO 5667-5; CSN EN ISO 5667-6; CSN EN ISO 5667-14; CSN EN ISO 5667-16; CSN EN ISO 19458)","search_en":"Drinking and raw water Sampling of drinking water and water used for its treatment (manual sampling) SOP21/LPV (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)","search_zh":"饮用水和原水 饮用水及其处理用水的采样（人工采样） SOP21/LPV (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-5; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a7771d86ee51247ea230d26","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie zawiesin metodą wagową","methodology_en":"Determination of suspended solids by gravimetry","methodology_zh":"重量法测定悬浮物","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesin metodą wagową","reference":"ČSN EN 872","norm_bases":["ČSN EN 872"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie zawiesin metodą wagową Odpadní a povrchové vody Stanovení nerozpuštěných látek gravimetricky ČSN EN 872 Scieki i wody powierzchniowe Oznaczanie zawiesin metoda wagowa Odpadni a povrchove vody Stanoveni nerozpustenych latek gravimetricky CSN EN 872","search_en":"Wastewater and surface water Determination of suspended solids by gravimetry ČSN EN 872","search_zh":"废水和地表水 重量法测定悬浮物 ČSN EN 872","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"590da5ab2797b0b07eb8bb72","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie substancji rozpuszczonych ogółem metodą wagową","methodology_en":"Determination of total dissolved solids by gravimetry","methodology_zh":"重量法测定总溶解物","methodology_cs":"Stanovení rozpuštěných látek celkových gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych ogółem metodą wagową","reference":"ČSN 75 7346","norm_bases":["ČSN 75 7346"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie substancji rozpuszczonych ogółem metodą wagową Odpadní a povrchové vody Stanovení rozpuštěných látek celkových gravimetricky ČSN 75 7346 Scieki i wody powierzchniowe Oznaczanie substancji rozpuszczonych ogolem metoda wagowa Odpadni a povrchove vody Stanoveni rozpustenych latek celkovych gravimetricky CSN 75 7346","search_en":"Wastewater and surface water Determination of total dissolved solids by gravimetry ČSN 75 7346","search_zh":"废水和地表水 重量法测定总溶解物 ČSN 75 7346","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50502a19172ba14ef7369587","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"3","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową i rozpuszczonych substancji organicznych obliczeniowo z wartości zmierzonych","methodology_en":"Determination of dissolved inorganic salts (RAS) by gravimetry and of dissolved organic substances by calculation from measured values","methodology_zh":"重量法测定溶解性无机盐 (RAS)，并由测量值计算溶解性有机物","methodology_cs":"Stanovení rozpuštěných anorganických solí (RAS) gravimetricky a rozpuštěných organických látek výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową i rozpuszczonych substancji organicznych obliczeniowo z wartości zmierzonych","reference":"SOP 8/LOV (ČSN 75 7346; ČSN 75 7347)","norm_bases":["SOP 8/LOV","ČSN 75 7346","ČSN 75 7347"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metodą wagową i rozpuszczonych substancji organicznych obliczeniowo z wartości zmierzonych Odpadní a povrchové vody Stanovení rozpuštěných anorganických solí (RAS) gravimetricky a rozpuštěných organických látek výpočtem z naměřených hodnot SOP 8/LOV (ČSN 75 7346; ČSN 75 7347) Scieki i wody powierzchniowe Oznaczanie rozpuszczonych soli nieorganicznych (RAS) metoda wagowa i rozpuszczonych substancji organicznych obliczeniowo z wartosci zmierzonych Odpadni a povrchove vody Stanoveni rozpustenych anorganickych soli (RAS) gravimetricky a rozpustenych organickych latek vypoctem z namerenych hodnot SOP 8/LOV (CSN 75 7346; CSN 75 7347)","search_en":"Wastewater and surface water Determination of dissolved inorganic salts (RAS) by gravimetry and of dissolved organic substances by calculation from measured values SOP 8/LOV (ČSN 75 7346; ČSN 75 7347)","search_zh":"废水和地表水 重量法测定溶解性无机盐 (RAS)，并由测量值计算溶解性有机物 SOP 8/LOV (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0f1595609c43d3512e90b043","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"4","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie BZT5 metodą elektrochemiczną","methodology_en":"Determination of BOD5 by electrochemical method","methodology_zh":"电化学法测定BSK5（五日生化需氧量）","methodology_cs":"Stanovení BSK5 elektrochemicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie BZT5 metodą elektrochemiczną","reference":"SOP 13/LOV (ČSN EN 1899-1; ČSN EN 1899-2)","norm_bases":["SOP 13/LOV","ČSN EN 1899-1","ČSN EN 1899-2"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie BZT5 metodą elektrochemiczną Odpadní a povrchové vody Stanovení BSK5 elektrochemicky SOP 13/LOV (ČSN EN 1899-1; ČSN EN 1899-2) Scieki i wody powierzchniowe Oznaczanie BZT5 metoda elektrochemiczna Odpadni a povrchove vody Stanoveni BSK5 elektrochemicky SOP 13/LOV (CSN EN 1899-1; CSN EN 1899-2)","search_en":"Wastewater and surface water Determination of BOD5 by electrochemical method SOP 13/LOV (ČSN EN 1899-1; ČSN EN 1899-2)","search_zh":"废水和地表水 电化学法测定BSK5（五日生化需氧量） SOP 13/LOV (ČSN EN 1899-1; ČSN EN 1899-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"180c4ce3b6cb9cea8a9de294","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"5","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie ChZT dwuchromianem potasu metodą fotometryczną komercyjnym zestawem analitycznym HACH","methodology_en":"Determination of COD with potassium dichromate by photometry with a HACH commercial analytical kit","methodology_zh":"使用HACH商品分析试剂盒重铬酸钾光度法测定化学需氧量 (CHSK)","methodology_cs":"Stanovení CHSK dichromanem draselným fotometricky analytickou komerční soupravou HACH","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ChZT dwuchromianem potasu metodą fotometryczną komercyjnym zestawem analitycznym HACH","reference":"SOP 1/LOV (ČSN ISO 15705; návod firmy HACH)","norm_bases":["SOP 1/LOV","ČSN ISO 15705","návod firmy HACH"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie ChZT dwuchromianem potasu metodą fotometryczną komercyjnym zestawem analitycznym HACH Odpadní a povrchové vody Stanovení CHSK dichromanem draselným fotometricky analytickou komerční soupravou HACH SOP 1/LOV (ČSN ISO 15705; návod firmy HACH) Scieki i wody powierzchniowe Oznaczanie ChZT dwuchromianem potasu metoda fotometryczna komercyjnym zestawem analitycznym HACH Odpadni a povrchove vody Stanoveni CHSK dichromanem draselnym fotometricky analytickou komercni soupravou HACH SOP 1/LOV (CSN ISO 15705; navod firmy HACH)","search_en":"Wastewater and surface water Determination of COD with potassium dichromate by photometry with a HACH commercial analytical kit SOP 1/LOV (ČSN ISO 15705; návod firmy HACH)","search_zh":"废水和地表水 使用HACH商品分析试剂盒重铬酸钾光度法测定化学需氧量 (CHSK) SOP 1/LOV (ČSN ISO 15705; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"012170a98cd29fc20a94622a","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"6","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie fosforu ogólnego metodą fotometryczną z molibdenianem amonu","methodology_en":"Determination of total phosphorus by photometry with ammonium molybdate","methodology_zh":"钼酸铵光度法测定总磷","methodology_cs":"Stanovení celkového fosforu fotometricky s molybdenanem amonným","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fosforu ogólnego metodą fotometryczną z molibdenianem amonu","reference":"SOP 2/LOV (ČSN EN ISO 6878)","norm_bases":["SOP 2/LOV","ČSN EN ISO 6878"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie fosforu ogólnego metodą fotometryczną z molibdenianem amonu Odpadní a povrchové vody Stanovení celkového fosforu fotometricky s molybdenanem amonným SOP 2/LOV (ČSN EN ISO 6878) Scieki i wody powierzchniowe Oznaczanie fosforu ogolnego metoda fotometryczna z molibdenianem amonu Odpadni a povrchove vody Stanoveni celkoveho fosforu fotometricky s molybdenanem amonnym SOP 2/LOV (CSN EN ISO 6878)","search_en":"Wastewater and surface water Determination of total phosphorus by photometry with ammonium molybdate SOP 2/LOV (ČSN EN ISO 6878)","search_zh":"废水和地表水 钼酸铵光度法测定总磷 SOP 2/LOV (ČSN EN ISO 6878)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"60217ca4f736d0953c32d5ae","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"7","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie azotu amonowego metodą fotometryczną i azotu nieorganicznego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ammonium nitrogen by photometry and of inorganic nitrogen by calculation from measured values","methodology_zh":"光度法测定氨氮，并由测量值计算无机氮","methodology_cs":"Stanovení dusíku amoniakálního fotometricky a anorganického výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu amonowego metodą fotometryczną i azotu nieorganicznego obliczeniowo z wartości zmierzonych","reference":"SOP 3/LOV (ČSN ISO 7150-1; Vyhláška MŽP č. 328/2018 Sb., částka 159)","norm_bases":["SOP 3/LOV","ČSN ISO 7150-1","Vyhláška MŽP č. 328/2018 Sb., částka 159"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie azotu amonowego metodą fotometryczną i azotu nieorganicznego obliczeniowo z wartości zmierzonych Odpadní a povrchové vody Stanovení dusíku amoniakálního fotometricky a anorganického výpočtem z naměřených hodnot SOP 3/LOV (ČSN ISO 7150-1; Vyhláška MŽP č. 328/2018 Sb., částka 159) Scieki i wody powierzchniowe Oznaczanie azotu amonowego metoda fotometryczna i azotu nieorganicznego obliczeniowo z wartosci zmierzonych Odpadni a povrchove vody Stanoveni dusiku amoniakalniho fotometricky a anorganickeho vypoctem z namerenych hodnot SOP 3/LOV (CSN ISO 7150-1; Vyhlaska MZP c. 328/2018 Sb., castka 159)","search_en":"Wastewater and surface water Determination of ammonium nitrogen by photometry and of inorganic nitrogen by calculation from measured values SOP 3/LOV (ČSN ISO 7150-1; Vyhláška MŽP č. 328/2018 Sb., částka 159)","search_zh":"废水和地表水 光度法测定氨氮，并由测量值计算无机氮 SOP 3/LOV (ČSN ISO 7150-1; Vyhláška MŽP č. 328/2018 Sb., částka 159)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b513463a7acc74f27873e78e","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"8","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie azotu azotynowego metodą fotometryczną","methodology_en":"Determination of nitrite nitrogen by photometry","methodology_zh":"光度法测定亚硝酸盐氮","methodology_cs":"Stanovení dusíku dusitanového fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu azotynowego metodą fotometryczną","reference":"SOP 4/LOV (ČSN EN 26777)","norm_bases":["SOP 4/LOV","ČSN EN 26777"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie azotu azotynowego metodą fotometryczną Odpadní a povrchové vody Stanovení dusíku dusitanového fotometricky SOP 4/LOV (ČSN EN 26777) Scieki i wody powierzchniowe Oznaczanie azotu azotynowego metoda fotometryczna Odpadni a povrchove vody Stanoveni dusiku dusitanoveho fotometricky SOP 4/LOV (CSN EN 26777)","search_en":"Wastewater and surface water Determination of nitrite nitrogen by photometry SOP 4/LOV (ČSN EN 26777)","search_zh":"废水和地表水 光度法测定亚硝酸盐氮 SOP 4/LOV (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"863f2b644d0fe8e796ccad86","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"9","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"ČSN ISO 10523","norm_bases":["ČSN ISO 10523"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie pH metodą potencjometryczną Odpadní a povrchové vody Stanovení pH potenciometricky ČSN ISO 10523 Scieki i wody powierzchniowe Oznaczanie pH metoda potencjometryczna Odpadni a povrchove vody Stanoveni pH potenciometricky CSN ISO 10523","search_en":"Wastewater and surface water Determination of pH by potentiometry ČSN ISO 10523","search_zh":"废水和地表水 电位法测定pH ČSN ISO 10523","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"33e47bf84b8537a627730e55","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"10","test_object":"Ścieki, wody powierzchniowe i surowe","test_object_en":"Wastewater, surface water and raw water","test_object_zh":"废水、地表水和原水","test_object_cs":"Odpadní, povrchové a surové vody","methodology":"Oznaczanie zawartości AOX metodą okresową (wsadową)","methodology_en":"Determination of AOX content by batch method","methodology_zh":"批量法测定AOX含量","methodology_cs":"Stanovení obsahu AOX vsádkovou metodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości AOX metodą okresową (wsadową)","reference":"ČSN EN ISO 9562","norm_bases":["ČSN EN ISO 9562"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, wody powierzchniowe i surowe Oznaczanie zawartości AOX metodą okresową (wsadową) Odpadní, povrchové a surové vody Stanovení obsahu AOX vsádkovou metodou ČSN EN ISO 9562 Scieki, wody powierzchniowe i surowe Oznaczanie zawartosci AOX metoda okresowa (wsadowa) Odpadni, povrchove a surove vody Stanoveni obsahu AOX vsadkovou metodou CSN EN ISO 9562","search_en":"Wastewater, surface water and raw water Determination of AOX content by batch method ČSN EN ISO 9562","search_zh":"废水、地表水和原水 批量法测定AOX含量 ČSN EN ISO 9562","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6cb2c681252719eb640ab5ad","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"11","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie azotu azotanowego z kwasem sulfosalicylowym metodą fotometryczną","methodology_en":"Determination of nitrate nitrogen with sulfosalicylic acid by photometry","methodology_zh":"磺基水杨酸光度法测定硝酸盐氮","methodology_cs":"Stanovení dusíku dusičnanového s kyselinou sulfosalicylovou fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu azotanowego z kwasem sulfosalicylowym metodą fotometryczną","reference":"SOP 5/LOV (ČSN ISO 7890-3)","norm_bases":["SOP 5/LOV","ČSN ISO 7890-3"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie azotu azotanowego z kwasem sulfosalicylowym metodą fotometryczną Odpadní a povrchové vody Stanovení dusíku dusičnanového s kyselinou sulfosalicylovou fotometricky SOP 5/LOV (ČSN ISO 7890-3) Scieki i wody powierzchniowe Oznaczanie azotu azotanowego z kwasem sulfosalicylowym metoda fotometryczna Odpadni a povrchove vody Stanoveni dusiku dusicnanoveho s kyselinou sulfosalicylovou fotometricky SOP 5/LOV (CSN ISO 7890-3)","search_en":"Wastewater and surface water Determination of nitrate nitrogen with sulfosalicylic acid by photometry SOP 5/LOV (ČSN ISO 7890-3)","search_zh":"废水和地表水 磺基水杨酸光度法测定硝酸盐氮 SOP 5/LOV (ČSN ISO 7890-3)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4950e8be1c0cd84d495124f8","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"12","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie azotu ogólnego po mineralizacji nadsiarczanem metodą fotometryczną, komercyjnym zestawem analitycznym HACH","methodology_en":"Determination of total nitrogen after persulphate digestion by photometry with a HACH commercial analytical kit","methodology_zh":"使用HACH商品分析试剂盒过硫酸盐消解光度法测定总氮","methodology_cs":"Stanovení dusíku celkového-persíranem fotometricky, analytickou komerční soupravou HACH","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego po mineralizacji nadsiarczanem metodą fotometryczną, komercyjnym zestawem analitycznym HACH","reference":"SOP 6/LOV (ČSN EN ISO 11905-1; návod firmy HACH)","norm_bases":["SOP 6/LOV","ČSN EN ISO 11905-1","návod firmy HACH"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie azotu ogólnego po mineralizacji nadsiarczanem metodą fotometryczną, komercyjnym zestawem analitycznym HACH Odpadní a povrchové vody Stanovení dusíku celkového-persíranem fotometricky, analytickou komerční soupravou HACH SOP 6/LOV (ČSN EN ISO 11905-1; návod firmy HACH) Scieki i wody powierzchniowe Oznaczanie azotu ogolnego po mineralizacji nadsiarczanem metoda fotometryczna, komercyjnym zestawem analitycznym HACH Odpadni a povrchove vody Stanoveni dusiku celkoveho-persiranem fotometricky, analytickou komercni soupravou HACH SOP 6/LOV (CSN EN ISO 11905-1; navod firmy HACH)","search_en":"Wastewater and surface water Determination of total nitrogen after persulphate digestion by photometry with a HACH commercial analytical kit SOP 6/LOV (ČSN EN ISO 11905-1; návod firmy HACH)","search_zh":"废水和地表水 使用HACH商品分析试剂盒过硫酸盐消解光度法测定总氮 SOP 6/LOV (ČSN EN ISO 11905-1; návod firmy HACH)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"13245a1954c36eff2430ab87","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"13","test_object":"Osady ściekowe","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"SOP 10/LOV (ČSN EN ISO 10390)","norm_bases":["SOP 10/LOV","ČSN EN ISO 10390"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady ściekowe Oznaczanie pH metodą potencjometryczną Kaly Stanovení pH potenciometricky SOP 10/LOV (ČSN EN ISO 10390) Osady sciekowe Oznaczanie pH metoda potencjometryczna Kaly Stanoveni pH potenciometricky SOP 10/LOV (CSN EN ISO 10390)","search_en":"Sludge Determination of pH by potentiometry SOP 10/LOV (ČSN EN ISO 10390)","search_zh":"污泥 电位法测定pH SOP 10/LOV (ČSN EN ISO 10390)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c7341ce4da5edc73c2b5e293","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"14","test_object":"Osady ściekowe","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Oznaczanie zawartości suchej masy i wody (sucha masa całkowita) oraz straty przy prażeniu (sucha masa organiczna) metodą wagową","methodology_en":"Determination of dry matter and water content (total solids) and of loss on ignition (organic solids) by gravimetry","methodology_zh":"重量法测定干物质含量和含水量（总固体）以及灼烧损失（有机固体）","methodology_cs":"Stanovení podílu sušiny a obsahu vody (celková sušina) a stanovení ztráty žíháním (organická sušina) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości suchej masy i wody (sucha masa całkowita) oraz straty przy prażeniu (sucha masa organiczna) metodą wagową","reference":"SOP 12/LOV (ČSN EN 15 934 metoda A; ČSN EN 15 935)","norm_bases":["SOP 12/LOV","ČSN EN 15 934 metoda A","ČSN EN 15 935"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady ściekowe Oznaczanie zawartości suchej masy i wody (sucha masa całkowita) oraz straty przy prażeniu (sucha masa organiczna) metodą wagową Kaly Stanovení podílu sušiny a obsahu vody (celková sušina) a stanovení ztráty žíháním (organická sušina) gravimetricky SOP 12/LOV (ČSN EN 15 934 metoda A; ČSN EN 15 935) Osady sciekowe Oznaczanie zawartosci suchej masy i wody (sucha masa calkowita) oraz straty przy prazeniu (sucha masa organiczna) metoda wagowa Kaly Stanoveni podilu susiny a obsahu vody (celkova susina) a stanoveni ztraty zihanim (organicka susina) gravimetricky SOP 12/LOV (CSN EN 15 934 metoda A; CSN EN 15 935)","search_en":"Sludge Determination of dry matter and water content (total solids) and of loss on ignition (organic solids) by gravimetry SOP 12/LOV (ČSN EN 15 934 metoda A; ČSN EN 15 935)","search_zh":"污泥 重量法测定干物质含量和含水量（总固体）以及灼烧损失（有机固体） SOP 12/LOV (ČSN EN 15 934 metoda A; ČSN EN 15 935)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b3831ccb67d459592df798a8","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"15","test_object":"Ścieki i wody powierzchniowe","test_object_en":"Wastewater and surface water","test_object_zh":"废水和地表水","test_object_cs":"Odpadní a povrchové vody","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度的测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"SOP 11/LOV (ČSN 757342)","norm_bases":["SOP 11/LOV","ČSN 757342"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Wastewater laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki i wody powierzchniowe Oznaczanie temperatury Odpadní a povrchové vody Stanovení teploty SOP 11/LOV (ČSN 757342) Scieki i wody powierzchniowe Oznaczanie temperatury Odpadni a povrchove vody Stanoveni teploty SOP 11/LOV (CSN 757342)","search_en":"Wastewater and surface water Determination of temperature SOP 11/LOV (ČSN 757342)","search_zh":"废水和地表水 温度的测定 SOP 11/LOV (ČSN 757342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b7178c9daecc27152d4bb4e3","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"1","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Povrchové vody","methodology":"Pobieranie próbek wód powierzchniowych (pobieranie ręczne)","methodology_en":"Sampling of surface water (manual sampling)","methodology_zh":"地表水采样（人工采样）","methodology_cs":"Odběr povrchových vod (manuální odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych (pobieranie ręczne)","reference":"SOP 7/LOV/a (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","norm_bases":["SOP 7/LOV/a","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Pobieranie próbek","regulatory_area_en":"Wastewater laboratory – Sampling","regulatory_area_zh":"废水实验室 – 采样","regulatory_area_cs":"Laboratoř odpadních vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych (pobieranie ręczne) Povrchové vody Odběr povrchových vod (manuální odběr) SOP 7/LOV/a (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14) Wody powierzchniowe Pobieranie probek wod powierzchniowych (pobieranie reczne) Povrchove vody Odber povrchovych vod (manualni odber) SOP 7/LOV/a (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN EN ISO 5667-6; CSN EN ISO 5667-14)","search_en":"Surface water Sampling of surface water (manual sampling) SOP 7/LOV/a (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","search_zh":"地表水 地表水采样（人工采样） SOP 7/LOV/a (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a3aa916e36876397e9aab8a5","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"2","test_object":"Osady ściekowe","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Pobieranie próbek osadów ściekowych (pobieranie ręczne)","methodology_en":"Sampling of sludge (manual sampling)","methodology_zh":"污泥采样（人工采样）","methodology_cs":"Odběr kalů (manuální odběr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów ściekowych (pobieranie ręczne)","reference":"SOP 9/LOV (ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN 16179; ČSN EN ISO 5667-14; Vyhláška č. 437/2016 Sb.)","norm_bases":["SOP 9/LOV","ČSN EN ISO 5667-13","ČSN EN ISO 5667-15","ČSN EN 16179","ČSN EN ISO 5667-14","Vyhláška č. 437/2016 Sb."],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Pobieranie próbek","regulatory_area_en":"Wastewater laboratory – Sampling","regulatory_area_zh":"废水实验室 – 采样","regulatory_area_cs":"Laboratoř odpadních vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady ściekowe Pobieranie próbek osadów ściekowych (pobieranie ręczne) Kaly Odběr kalů (manuální odběr) SOP 9/LOV (ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN 16179; ČSN EN ISO 5667-14; Vyhláška č. 437/2016 Sb.) Osady sciekowe Pobieranie probek osadow sciekowych (pobieranie reczne) Kaly Odber kalu (manualni odber) SOP 9/LOV (CSN EN ISO 5667-13; CSN EN ISO 5667-15; CSN EN 16179; CSN EN ISO 5667-14; Vyhlaska c. 437/2016 Sb.)","search_en":"Sludge Sampling of sludge (manual sampling) SOP 9/LOV (ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN 16179; ČSN EN ISO 5667-14; Vyhláška č. 437/2016 Sb.)","search_zh":"污泥 污泥采样（人工采样） SOP 9/LOV (ČSN EN ISO 5667-13; ČSN EN ISO 5667-15; ČSN EN 16179; ČSN EN ISO 5667-14; Vyhláška č. 437/2016 Sb.)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"90e6c85c5d83751768ec0b2f","lab_id":"69ad52a4de79e566650fd37e","country":"CZ","accr_number":"1324","accr_body":"ČIA","row_label":"3","test_object":"Ścieki","test_object_en":"Wastewater","test_object_zh":"废水","test_object_cs":"Odpadní vody","methodology":"Pobieranie próbek ścieków (pobieranie ręczne i automatycznym próbnikiem)","methodology_en":"Sampling of wastewater (manual sampling and sampling by automatic sampler)","methodology_zh":"废水采样（人工采样和自动采样器采样）","methodology_cs":"Odběr odpadních vod (manuální odběr a odběr automatickým vzorkovačem)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków (pobieranie ręczne i automatycznym próbnikiem)","reference":"SOP 7/LOV/b (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","norm_bases":["SOP 7/LOV/b","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 75 7315"],"lab_section":"Laboratorium ścieków","lab_section_en":"Wastewater laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"ČOV, Kroměřížská 646/10a, 682 01 Vyškov Předměstí","regulatory_area":"Laboratorium ścieków – Pobieranie próbek","regulatory_area_en":"Wastewater laboratory – Sampling","regulatory_area_zh":"废水实验室 – 采样","regulatory_area_cs":"Laboratoř odpadních vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków (pobieranie ręczne i automatycznym próbnikiem) Odpadní vody Odběr odpadních vod (manuální odběr a odběr automatickým vzorkovačem) SOP 7/LOV/b (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) Scieki Pobieranie probek sciekow (pobieranie reczne i automatycznym probnikiem) Odpadni vody Odber odpadnich vod (manualni odber a odber automatickym vzorkovacem) SOP 7/LOV/b (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 75 7315)","search_en":"Wastewater Sampling of wastewater (manual sampling and sampling by automatic sampler) SOP 7/LOV/b (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","search_zh":"废水 废水采样（人工采样和自动采样器采样） SOP 7/LOV/b (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}