🇨🇿 Vodovody a kanalizace Břeclav, a.s. PL

ČIA 1293 • Břeclav, Czech Republic • 53 methods

Water & wastewaterMicrobiology

Vodovody a kanalizace Břeclav, a.s. is a laboratory accredited by ČIA under number 1293 (Břeclav, Czech Republic). Its accreditation scope covers 53 test methods in the following areas: Water & wastewater, Microbiology. Test objects include: Drinking, raw, ground, surface, process and hot water, Drinking, ground, surface and waste water, Drinking, raw, ground, surface, process, hot and waste water, Drinking, raw, ground, process and hot water. Most frequently used techniques: spectrophotometric method, gravimetric method, membrane filtration method.

At a glance

  • Accreditation number: ČIA 1293
  • Methods in scope: 53
  • Types of test objects: 17
  • Techniques used: 21
  • City: Břeclav, Czech Republic
  • Valid until: 07-11-2028
Accreditation number
1293
Accreditation body
ČIA
Address
Čechova 1300/23, 690 02 Břeclav
City
Břeclav, Czech Republic
Division
Laboratoria Gospodarki Wodnej
Valid until
07-11-2028

What this laboratory tests (17)

Analytical techniques used (21)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
07.11.2023

Accreditation scope — test methods (53)

No. Test object Methodology / Parameters Technique Reference document
Břeclav Water Treatment Plant Laboratory
1 Drinking, raw, ground, surface, process and hot water Determination of pH by potentiometry
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
potentiometric method SOP č. 1 (ČSN ISO 10523)
2 Drinking, raw, ground, surface, process and hot water Determination of electrical conductivity
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
SOP č. 2 (ČSN EN 27888)
3 Drinking, ground and hot water Determination of total and free chlorine spectrophotometrically using a Hach commercial analytical kit
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method, Hach commercial analytical kit SOP č. 3 (ČSN EN ISO 7393-2; návod firmy Hach)
4 Drinking, raw, ground, surface, process and hot water Determination of chemical oxygen demand by permanganate (CODMn) by titration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
titrimetric method SOP č. 4 (ČSN EN ISO 8467)
5 Drinking, raw, ground, surface, process, hot and waste water Determination of calcium by titration, determination of magnesium by calculation
magnesium by calculation (calculated)
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
titrimetric method SOP č. 6a (ČSN ISO 6058)
6 Drinking, raw, ground, surface, process, hot and waste water Determination of the sum of calcium and magnesium by titration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
titrimetric method SOP č. 6b (ČSN ISO 6059)
7 Drinking, raw, ground, surface, process, hot and waste water Determination of iron spectrophotometrically with 1,10-phenanthroline
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method with 1,10-phenanthroline SOP č. 7 (ČSN ISO 6332)
8 Drinking, raw, ground, surface, process, hot and waste water Determination of manganese spectrophotometrically with formaldoxime
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method with formaldoxime SOP č. 8 (ČSN ISO 6333)
9 Drinking, raw, ground, surface, process and hot water Determination of ammonium ions spectrophotometrically
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 9 (ČSN ISO 7150-1)
10 Drinking, raw, ground, surface, process and hot water Determination of acid neutralising capacity (KNK4.5) by titration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
titrimetric method SOP č. 11 (ČSN EN ISO 9963-1)
11 Drinking, raw, ground, surface, process, hot and waste water Determination of chlorides by argentometric titration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
argentometric titration SOP č. 12 (ČSN ISO 9297)
12 Drinking, raw, ground, surface, process, hot and waste water Determination of sulphates by titration with lead nitrate
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
titration with lead nitrate SOP č. 13 (ČSN 757477)
13 Drinking, raw, ground, surface, process and hot water Determination of nitrites spectrophotometrically
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 14 (ČSN EN 26777)
14 Drinking, raw, ground, surface, process and hot water Determination of nitrates spectrophotometrically with sulfosalicylic acid
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method with sulfosalicylic acid SOP č. 15 (ČSN ISO 7890-3)
15 Drinking, raw, ground, surface and process water Determination of suspended solids by gravimetry
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
gravimetric method SOP č. 18a (ČSN EN 872)
16 Drinking, raw, ground, surface and process water Determination of dissolved solids, inorganic (RAS) and organic substances (loss on ignition) by gravimetry
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
gravimetric method SOP č. 19 (ČSN 75 7346; ČSN 75 7347)
17 Drinking and hot water Determination of chlorine dioxide spectrophotometrically using a Hach commercial analytical kit
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method, Hach commercial analytical kit SOP č. 20 (návod firmy Hach)
18 Drinking, raw, ground, surface, process and hot water Determination of absorbance at 254 nm by photometry
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
photometric method SOP č. 21 (ČSN 75 7360)
19 Drinking, raw, ground, surface, process and hot water Determination of turbidity by nephelometry
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
nephelometric method SOP č. 26 (ČSN EN ISO 7027-1)
20 Drinking, raw, ground, surface, process and hot water Determination of colour by visual comparison
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
visual comparison SOP č. 27 (ČSN EN ISO 7887)
21 Drinking, raw, ground, surface, process and hot water Determination of fluorides spectrophotometrically with zirconium alizarin
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method with zirconium alizarin SOP č. 28 (TNV 75 7431)
22 Drinking, raw, ground, surface, process and hot water Determination of temperature
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
ČSN 75 7342
23 Drinking, raw, ground, surface, process and hot water Determination of phosphates spectrophotometrically
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 30 (ČSN EN ISO 6878)
24 Drinking, ground and hot water Determination of odour and taste – sensory analysis
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
sensory analysis SOP č. 31 (ČSN EN 1622; ČSN 75 7340)
25 Drinking, raw, ground, surface, process and hot water Determination of dissolved oxygen by luminescence method with an optical probe
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
luminescence method with an optical probe SOP č. 32 (ČSN ISO 17289)
26 Drinking, raw, ground, surface, process and hot water Determination of aluminium spectrophotometrically
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 41 (ČSN ISO 10566)
27 Drinking, raw, ground, process and hot water Determination of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
membrane filtration method ČSN EN ISO 9308-1
28 Non-disinfected, drinking, raw, ground, process and hot water Determination of coliform bacteria by membrane filtration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
membrane filtration method ČSN 75 7837
29 Drinking, raw, ground, process and hot water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
membrane filtration method ČSN 75 7835
30 Drinking, raw, ground, process and hot water Determination of intestinal enterococci by membrane filtration
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
membrane filtration method ČSN EN ISO 7899-2
31 Drinking, raw, ground, process and hot water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium a) at 22 °C b) at 36 °C
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
inoculation in a nutrient agar culture medium ČSN EN ISO 6222
32 Drinking, raw and ground water Biological analysis – determination of bioseston. Determination of the number of organisms by microscopy
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
microscopic method ČSN 75 7712
33 Drinking, raw and ground water Biological analysis – determination of abioseston by microscopy
Regulated area: Břeclav Water Treatment Plant Laboratory – Tests
microscopic method ČSN 75 7713
34 Ground and drinking water Sampling of ground water and drinking water from water treatment plants (manual sampling, sampling with a sampling pump)
Regulated area: Břeclav Water Treatment Plant Laboratory – Sampling
SVP č. 1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN ISO 5667- 5; ČSN ISO 5667- 11; ČSN EN ISO 19458)
35 Drinking water Sampling of drinking water from water supply networks (manual sampling)
Regulated area: Břeclav Water Treatment Plant Laboratory – Sampling
SVP č. 2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN ISO 5667- 5; ČSN EN ISO 19458)
36 Surface water Sampling of surface water (manual sampling and sampling with an automatic sampler)
Regulated area: Břeclav Water Treatment Plant Laboratory – Sampling
SVP č. 3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667- 4)
Břeclav Wastewater Treatment Plant Laboratory
37 Drinking, ground, surface and waste water Determination of pH by potentiometry
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
potentiometric method SOP č. 1 (ČSN ISO 10523)
38 Drinking, ground, surface and waste water Determination of chemical oxygen demand by potassium dichromate (CODCr) spectrophotometrically
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 5 (ČSN ISO 15705)
39 Surface and waste water Determination of ammonium ions (NH4+) by titration after distillation and ammonium nitrogen (N-NH4+) by calculation
ammonium nitrogen (N-NH4+) by calculation (calculated)
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
titration after distillation SOP č. 10 (ČSN ISO 5664)
40 Drinking, ground, surface and waste water Determination of nitrites (NO2-) spectrophotometrically and nitrite nitrogen (N-NO2-) by calculation
nitrite nitrogen (N-NO2-) by calculation (calculated)
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 14 (ČSN EN 26777)
41 Drinking, ground, surface and waste water Determination of nitrates (NO3-) spectrophotometrically and nitrate nitrogen (N-NO3-) by calculation
nitrate nitrogen (N-NO3-) by calculation (calculated)
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 15 (ČSN ISO 7890-3)
42 Drinking, ground, surface and waste water Determination of total phosphorus spectrophotometrically
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 16 (ČSN EN ISO 6878)
43 Drinking, ground, surface and waste water Determination of biochemical oxygen demand after 5 days (BOD5) by the standard dilution method with suppression of nitrification using an optical luminescence probe
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
standard dilution method with nitrification suppression, optical luminescence probe SOP č. 17 (ČSN EN ISO 5815-1)
44 Drinking, ground, surface and waste water, activated sludge Determination of suspended solids by gravimetry
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
gravimetric method SOP č. 18a (ČSN EN 872)
45 Drinking, ground, surface and waste water Determination of dissolved solids, inorganic (RAS) and organic substances (loss on ignition) by gravimetry
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
gravimetric method SOP č. 19 (ČSN 75 7346; ČSN 75 7347)
46 Surface and waste water, activated sludge Determination of loss on ignition of suspended solids by gravimetry
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
gravimetric method SOP č. 18b (ČSN 75 7350)
47 Drinking, ground, surface and waste water, activated sludge Determination of temperature
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
ČSN 75 7342
48 Drinking, ground, surface and waste water Determination of phosphates spectrophotometrically
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
spectrophotometric method SOP č. 30 (ČSN EN ISO 6878)
49 Drinking, ground, surface and waste water, activated sludge Determination of dissolved oxygen by luminescence method with an optical probe
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
luminescence method with an optical probe SOP č. 32 (ČSN ISO 17289)
50 Drinking, ground, surface and waste water Determination of total nitrogen spectrophotometrically – Hach commercial analytical kit, determination of inorganic and organic nitrogen by calculation
inorganic and organic nitrogen by calculation (calculated)
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Tests
spectrophotometric method, Hach commercial analytical kit SOP č. 36 (ČSN EN ISO 11905-1; návod firmy Hach)
51 Surface water Sampling of surface water (manual sampling and sampling with an automatic sampler)
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Sampling
SVP č. 3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN ISO 5667- 4)
52 Waste water Sampling of waste water (manual sampling and sampling with an automatic sampler)
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Sampling
SVP č. 4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
53 Sewage and waterworks sludges, grit and screenings Sampling of sludges (manual sampling)
Regulated area: Břeclav Wastewater Treatment Plant Laboratory – Sampling
SVP č. 7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)

Reference standards (89)

SOP č. 1
SOP č. 10
SOP č. 11
SOP č. 12
SOP č. 13
SOP č. 14
SOP č. 15
SOP č. 16
SOP č. 17
SOP č. 18a
SOP č. 18b
SOP č. 19
SOP č. 2
SOP č. 20
SOP č. 21
SOP č. 26
SOP č. 27
SOP č. 28
SOP č. 3
SOP č. 30
SOP č. 31
SOP č. 32
SOP č. 36
SOP č. 4
SOP č. 41
SOP č. 5
SOP č. 6a
SOP č. 6b
SOP č. 7
SOP č. 8
SOP č. 9
SVP č. 1
SVP č. 2
SVP č. 3
SVP č. 4
SVP č. 7
TNV 75 7431
návod firmy Hach
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN 757477
ČSN EN 1622
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 11905-1
ČSN EN ISO 19458
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 10566
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 5664
ČSN ISO 5667- 11
ČSN ISO 5667- 4
ČSN ISO 5667- 5
ČSN ISO 5667-10
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1293