🇨🇿 ORLICKÁ LABORATOŘ, s.r.o. PL
Water & wastewaterEnvironmentMicrobiologyFood & beverages
ORLICKÁ LABORATOŘ, s.r.o. is a laboratory accredited by ČIA under number 1277 (Česká Třebová, Czech Republic). Its accreditation scope covers 82 test methods in the following areas: Water & wastewater, Environment, Microbiology, Food & beverages. Test objects include: Drinking, bottled, raw, treated, hot, ground, surface, bathing and…, Earths, soils, sludge, sediments, composts, waste, sands, Drinking, bottled, raw, treated, hot, ground, surface, bathing and…, Food, food supplements.
At a glance
- Accreditation number: ČIA 1277
- Methods in scope: 82
- Types of test objects: 32
- City: Česká Třebová, Czech Republic
- Valid until: 07-09-2028
- Accreditation number
- 1277
- Accreditation body
- ČIA
- Address
- Lhotka 219, 560 02 Česká Třebová
- City
- Česká Třebová, Czech Republic
- Division
- ORLICKÁ LABORATOŘ
- Valid until
- 07-09-2028
What this laboratory tests (32)
- Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate — 12 methods
- Earths, soils, sludge, sediments, composts, waste, sands — 10 methods
- Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water — 8 methods
- Food, food supplements — 6 methods
- Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water — 5 methods
- Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) — 4 methods
- Drinking, bottled, raw, treated, hot, ground water — 2 methods
- Drinking, bottled, raw, treated, hot, ground, surface water — 2 methods
- Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water — 2 methods
- Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water — 2 methods
- Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate — 2 methods
- Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) — 2 methods
- Drinking, bottled, raw, treated, hot, ground, surface, waste water — 2 methods
- Earths, soils, sludge, sediments, composts, waste — 2 methods
- Earths, soils, sludge, sediments, composts, waste, sands, waste water — 2 methods
- and 17 more
Certificate information
- Certificate date
- 19.05.2025
Accreditation scope — test methods (82)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration (culture) Regulated area: Tests |
ZP 002 (ČSN 75 7835) | ||
| 2 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Enumeration of intestinal enterococci by membrane filtration (culture) Regulated area: Tests |
ZP 003 (ČSN EN ISO 7899-2) | ||
| 3 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water | Enumeration of culturable micro-organisms by inoculation in a nutrient medium (culture) a) at 22 °C b) at 36 °C Regulated area: Tests |
ZP 004 (ČSN EN ISO 6222) | ||
| 4 | Drinking, bottled, raw, treated, hot, ground, surface water | Biological analysis - Determination of abioseston by microscopy Regulated area: Tests |
ZP 005 (ČSN 75 7713) | ||
| 5 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Biological analysis - Determination of bioseston by microscopy Regulated area: Tests |
ZP 006 (ČSN 75 7712) | ||
| 6 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water | Enumeration of Escherichia coli and coliform bacteria by membrane filtration on chromogenic agar (culture) Regulated area: Tests |
ZP 007 (ČSN EN ISO 9308-1) | ||
| 7 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Enumeration of Pseudomonas aeruginosa by membrane filtration (culture) Regulated area: Tests |
ZP 008 (ČSN EN ISO 16266) | ||
| 8 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Enumeration of coagulase-positive staphylococci by membrane filtration (culture) Regulated area: Tests |
ZP 009 (ČSN EN ISO 6888-1) | ||
| 9 | Drinking, bottled, raw, treated, hot, ground, surface water | Enumeration of Clostridium perfringens by membrane filtration (culture) Regulated area: Tests |
ZP 010 (ČSN EN ISO 14189) | ||
| 10 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water | Enumeration of Legionella by membrane filtration (culture) Regulated area: Tests |
ZP 011 (ČSN EN ISO 11731) | ||
| 11 | Earths, soils, sludge, sediments, composts, waste, sands, waste water | Detection of Salmonella after enrichment (culture) Regulated area: Tests |
ZP 012 (AHEM č. 1/2008) | ||
| 12 | Earths, soils, sludge, sediments, composts, waste, sands, waste water | Enumeration of indicator micro-organisms by the spread plate method (culture) Regulated area: Tests |
ZP 013 (AHEM č. 1/2008) | ||
| 13 | Food, food supplements | Enumeration of yeasts and moulds by the spread plate method (culture) Regulated area: Tests |
ZP 015 (ČSN ISO 21527-1; ČSN ISO 21527-2) | ||
| 14 | Food, food supplements | Enumeration of coliforms by the pour plate or spread plate method (culture) Regulated area: Tests |
ZP 016 (ČSN ISO 4832) | ||
| 15 | Food, food supplements | Enumeration of β-glucuronidase-positive Escherichia coli by the pour plate or spread plate method on chromogenic agar (culture) Regulated area: Tests |
ZP 017 (ČSN ISO 16649-2) | ||
| 16 | Food, food supplements | Detection of Salmonella after enrichment (culture) Regulated area: Tests |
ZP 018 (ČSN EN ISO 6579-1) | ||
| 17 | Food, food supplements | Enumeration of total micro-organisms by the pour plate or spread plate method (culture) Regulated area: Tests |
ZP 020 (ČSN EN ISO 4833-1; ČSN EN ISO 4833-2) | ||
| 18 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, air | Determination of temperature Regulated area: Tests |
ZP 021 (ČSN 75 7342) | ||
| 19 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water | Determination of colour by spectrophotometry Regulated area: Tests |
ZP 022 (ČSN EN ISO 7887) | ||
| 20 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water | Determination of turbidity by nephelometry Regulated area: Tests |
ZP 023 (ČSN EN ISO 7027-1) | ||
| 21 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Indicative sensory analysis Regulated area: Tests |
ZP 024 (ČSN 75 7340) | ||
| 22 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of pH by potentiometry Regulated area: Tests |
ZP 025 (ČSN ISO 10523) | ||
| 23 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of electrical conductivity Regulated area: Tests |
ZP 026 (ČSN EN 27888) | ||
| 24 | Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water | Determination of acid neutralising capacity (ANC) by titration, calculation of Langelier index, hydrogencarbonates and carbonates, carbonate and non-carbonate hardness, free, bound and aggressive CO2, total mineralisation Regulated area: Tests |
ZP 027 (ČSN EN ISO 9963-1) | ||
| 25 | Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water | Determination of base neutralising capacity (BNC) by titration Regulated area: Tests |
ZP 028 (ČSN 75 7372) | ||
| 26 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of dissolved solids and dissolved inorganic salts (DIS) by gravimetry Regulated area: Tests |
ZP 030 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216; ČSN 75 7300) | ||
| 27 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of suspended solids by gravimetry Regulated area: Tests |
ZP 031 (ČSN EN 872) | ||
| 28 | Ground, surface, process and industrial, waste water, aqueous leachate | Determination of extractable substances by gravimetry (ELGR) Regulated area: Tests |
ZP 034 (ČSN 75 7508) | ||
| 29 | Ground, surface, process and industrial, waste water, aqueous leachate | Determination of ammonium by titration after distillation and calculation of ammoniacal nitrogen Regulated area: Tests |
ZP 036 (ČSN ISO 5664) | ||
| 30 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of ammonium by spectrophotometry and calculation of ammoniacal nitrogen Regulated area: Tests |
ZP 037 (ČSN ISO 7150-1) | ||
| 31 | Drinking, bottled, raw, treated, hot, ground, surface, process and industrial water | Determination of chemical oxygen demand with permanganate (COD-Mn) by titration Regulated area: Tests |
ZP 043 (ČSN EN ISO 8467) | ||
| 32 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry Regulated area: Tests |
ZP 044 (ČSN ISO 15705) | ||
| 33 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, waste water, aqueous leachate | Determination of biochemical oxygen demand after n days (BODn) by the electrochemical method with a membrane probe Regulated area: Tests |
ZP 045 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 34 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of dissolved oxygen by the electrochemical method with a membrane probe and calculation of dissolved oxygen in % Regulated area: Tests |
ZP 046 (ČSN EN ISO 5814) | ||
| 35 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of dissolved oxygen with an optical probe and calculation of dissolved oxygen in % Regulated area: Tests |
ZP 104 (ČSN ISO 17289) | ||
| 36 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Determination of humic substances by spectrophotometry Regulated area: Tests |
ZP 047 (ČSN 75 7536) | ||
| 37 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of anionic surfactants by spectrophotometry Regulated area: Tests |
ZP 048 (ČSN EN 903) | ||
| 38 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of monohydric phenols by spectrophotometry Regulated area: Tests |
ZP 052 (ČSN ISO 6439) | ||
| 39 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | Determination of absorbance at 254 nm by spectrophotometry Regulated area: Tests |
ZP 053 (ČSN 75 7360) | ||
| 40 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, waste water | Determination of total and free chlorine by spectrophotometry with a HACH commercial kit and calculation of combined chlorine and chlorine dioxide Regulated area: Tests |
ZP 055 (ČSN EN ISO 7393-2; návod firmy Hach) | ||
| 41 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) | Determination of total cyanides by spectrophotometry Regulated area: Tests |
ZP 056 (ČSN 75 7415) | ||
| 42 | Sludge | Determination of total, undissolved and settleable solids and calculation of the sludge index by gravimetry Regulated area: Tests |
ZP 060 (ČSN EN 14702-1; M. Sedláček a kol., Metody rozboru kalů a pevných odpadů, SZN 1978) | ||
| 43 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of dry matter, moisture, combustible matter and loss on ignition by gravimetry Regulated area: Tests |
ZP 061 (ČSN 46 5735; ČSN EN 15935; ČSN EN 15934) | ||
| 44 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of pH of solids by potentiometry Regulated area: Tests |
ZP 062 (ČSN EN ISO 10390) | ||
| 45 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of Kjeldahl nitrogen Regulated area: Tests |
ZP 063 (ČSN EN 13342) | ||
| 46 | Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate | Determination of non-ionic surfactants by spectrophotometry Regulated area: Tests |
ZP 050 (návod firmy Hach) | ||
| 47 | Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) | Determination of formaldehyde by spectrophotometry Regulated area: Tests |
ZP 051 (návod firmy Hach) | ||
| 48 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) | Determination of radon 222Rn in water samples by gamma radiation measurement Regulated area: Tests |
ZP 105 (ČSN 75 7624; ČSN 75 7600; návod firmy Diram) | ||
| 49 | Drinking, bottled, raw, treated, hot, ground water | Determination of gross beta activity concentration by measuring the evaporation residue with a proportional detector and of gross beta activity corrected for potassium 40 by calculation, and calculation of the total indicative dose Regulated area: Tests |
ZP 085 (ČSN 75 7612; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Empos; doporučení SÚJB) | ||
| 50 | Drinking, bottled, raw, treated, hot, ground water | Determination of gross alpha activity concentration by measuring the evaporation residue mixed with ZnS (Ag) scintillator and of gross alpha activity corrected for uranium by calculation Regulated area: Tests |
ZP 106 (ČSN 75 7611; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Diram; doporučení SÚJB) | ||
| 51 | Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: Tests |
ZP 071a (ČSN EN ISO 9562; ČSN EN 16166) | ||
| 52 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: Tests |
ZP 071b (ČSN EN ISO 9562; ČSN EN 16166) | ||
| 53 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, earths, soils, sludge, sediments, composts, waste, sands, plant products, food, food supplements | Determination of total mercury with a dedicated atomic absorption spectrometer Regulated area: Tests |
ZP 072 (ČSN 75 7440; ČSN EN 13806) | ||
| 54 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of volatile organic compounds by GC/FID/ECD and calculation of the sum of BTEX, CU and TOL chloroethene 1,1-dichloroethene dichloromethane cis-1,2-dichloroethene trans-1,2-dichloroethene chloroform tetrachloromethane 1,2-dichloroethane trichloroethylene bromodichloromethane tetrachloroethylene dibromochloromethane bromoform o-dichlorobenzene m-dichlorobenzene p-dichlorobenzene benzene toluene chlorobenzene ethylbenzene o-xylene m-xylene p-xylene styrene Regulated area: Tests |
ZP 073a (TNV 75 7552; ČSN EN ISO 22155) | ||
| 55 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of volatile organic compounds by GC/FID/ECD and calculation of the sum of BTEX, THM, CU and TOL benzene trichloroethylene toluene tetrachloroethylene ethylbenzene m+p-xylene o-xylene Regulated area: Tests |
ZP 073b (TNV 75 7552; ČSN EN ISO 22155) | ||
| 56 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water | Determination of hydrocarbons C10 to C40 by GC/FID Regulated area: Tests |
ZP 074a (ČSN EN ISO 9377-2) | ||
| 57 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of hydrocarbons C10 to C40 by GC/FID Regulated area: Tests |
ZP 074b (ČSN EN 14039; ČSN EN ISO 16703) | ||
| 58 | Drinking, bottled, raw, treated, hot, ground, surface, waste water | Determination of polycyclic aromatic hydrocarbons by HPLC/FluD/DAD and calculation of the sum of PAH fluoranthene benzo(a)pyrene benzo(b)fluoranthene benzo(g,h,i)perylene indeno(1,2,3-cd)pyrene benzo(k)fluoranthene naphthalene phenanthrene chrysene pyrene anthracene benzo(a)anthracene acenaphthylene acenaphthene fluorene dibenzo(a,h)anthracene Regulated area: Tests |
ZP 075a (ČSN EN ISO 17993) | ||
| 59 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of polycyclic aromatic hydrocarbons by HPLC/FluD/DAD and calculation of the sum of PAH anthracene benzo(a)anthracene benzo(a)pyrene benzo(b)fluoranthene benzo(g,h,i)perylene benzo(k)fluoranthene chrysene fluoranthene indeno(1,2,3-cd)pyrene phenanthrene pyrene naphthalene acenaphthylene acenaphthene fluorene dibenzo(a,h)anthracene Regulated area: Tests |
ZP 075b (ČSN EN ISO 17993; ČSN EN 17503) | ||
| 60 | Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) | Determination of chlorides by spectrophotometry with a HACH kit Regulated area: Tests |
ZP 090a (návod firmy Hach) | ||
| 61 | Solid sorbents (emissions, indoor and workplace air) | Determination of chlorides by spectrophotometry with a HACH kit and calculation of trichloramine Regulated area: Tests |
ZP 090b (návod firmy Hach) | ||
| 62 | Drinking, bottled, raw, treated, hot, ground, surface, waste water | Determination of polychlorinated biphenyls by GC/MS and calculation of the sum of PCB PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Regulated area: Tests |
ZP 093a (ČSN ISO 17858) | ||
| 63 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of polychlorinated biphenyls by GC/MS and calculation of the sum of PCB PCB 28 PCB 52 PCB 101 PCB 118 PCB 138 PCB 153 PCB 180 Regulated area: Tests |
ZP 093b (ČSN EN 17322) | ||
| 64 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate | Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by catalytic combustion with IR detection and calculation of the TOC difference parameter Regulated area: Tests |
ZP 094 (ČSN EN 1484; ČSN EN ISO 20236) | ||
| 65 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water | Determination of total bound nitrogen (TNb) after oxidation to nitrogen oxides with chemiluminescence detection and calculation of inorganic and organic nitrogen Regulated area: Tests |
ZP 095 (ČSN EN ISO 20236) | ||
| 66 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions and solid sorbents (emissions, indoor and workplace air) | Determination of dissolved anions by IC, calculation of the sum of nitrites and nitrates, total acid content and of the nitrate difference parameter bromates fluorides chlorides nitrites nitrates phosphates sulphates nitrite nitrogen nitrate nitrogen chlorites chlorates Regulated area: Tests |
ZP 100 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) | ||
| 67 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) | Determination of dissolved cations by IC and calculation of the sum of calcium and magnesium, total hardness and free ammonia Lithium (Li+) Sodium (Na+) Ammonium (NH4+) Potassium (K+) Calcium (Ca2+) Magnesium (Mg2+) Ammonium nitrogen (N-NH4+) sum Ca+Mg (calculated) Regulated area: Tests |
ZP 101 (ČSN EN ISO 14911) | ||
| 68 | Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) | Determination of elements by ICP/MS Silver (Ag) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Hexavalent chromium (CrVI) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Thallium (Tl) Vanadium (V) Zinc (Zn) Uranium (U) Regulated area: Tests |
ZP 102a (ČSN EN ISO 17294-2; ČSN EN ISO 15587-2) | ||
| 69 | Earths, soils, sludge, sediments, composts, waste, sands | Determination of elements by ICP/MS Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Manganese (Mn) Magnesium (Mg) Nickel (Ni) Phosphorus (P) Lead (Pb) Tin (Sn) Vanadium (V) Zinc (Zn) Regulated area: Tests |
ZP 102b (ČSN EN ISO 17294-2; ČSN EN 13656; ČSN EN 13657; ČSN EN 16171) | ||
| 70 | Solid sorbents (emissions, indoor and workplace air) | Determination of elements by ICP/MS Arsenic (As) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Hexavalent chromium (CrVI) Copper (Cu) Manganese (Mn) Nickel (Ni) Lead (Pb) Antimony (Sb) Tin (Sn) Thallium (Tl) Vanadium (V) Zinc (Zn) Selenium (Se) Regulated area: Tests |
ZP 102c (ČSN EN ISO 17294-2; ČSN EN 14902) | ||
| 71 | Plant products | Determination of elements by ICP/MS Aluminium (Al) Beryllium (Be) Cadmium (Cd) Copper (Cu) Chromium (Cr) Iron (Fe) Manganese (Mn) Nickel (Ni) Lead (Pb) Zinc (Zn) Arsenic (As) Regulated area: Tests |
ZP 102d (ČSN EN ISO 17294-2; ČSN EN 13805) | ||
| 72 | Food, food supplements | Determination of elements by ICP/MS Cadmium (Cd) Copper (Cu) Iron (Fe) Lead (Pb) Zinc (Zn) Aluminium (Al) Chromium (Cr) Nickel (Ni) Arsenic (As) Regulated area: Tests |
ZP 102e (ČSN EN ISO 17294-2; ČSN EN 13805) | ||
| 73 | Earths, soils, sludge, sediments, composts, waste | Determination of extractable organically bound halogens (EOX) by coulometry Regulated area: Tests |
ZP 077 (DIN 38414-17; návod firmy Labtech) | ||
| 74 | Earths, soils, sludge, sediments, composts, waste | Determination of respiration activity (AT4) by measuring oxygen consumption after 4 days by coulometry Regulated area: Tests |
ZP 078 (ONORM S 2027-4; Návod firmy DIRAM) | ||
| 75 | Drinking, bottled, raw, treated, hot water | Sampling of drinking water Regulated area: Sampling |
VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 76 | Waste water | Sampling of waste water (manual sampling, automatic sampler) Regulated area: Sampling |
VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 77 | Surface water | Sampling of surface water Regulated area: Sampling |
VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14) | ||
| 78 | Bathing and therapeutic water | Sampling of bathing water Regulated area: Sampling |
VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458) | ||
| 79 | Ground water | Sampling of ground water (manual sampling, pumping) Regulated area: Sampling |
VZ 05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN ISO 5667-18) | ||
| 80 | Earths, soils, sludge, sediments, composts, waste, sands | Sampling of waste and solids Regulated area: Sampling |
VZ 07 (Metodický pokyn MŽP ke vzorkování odpadů – duben 2008; ČSN EN 14899) | ||
| 81 | Air of swimming pools | Sampling for the determination of volatile substances in air by trapping on a solid sorbent Regulated area: Sampling |
VZ 08 (M. Hery, Ann.Occup.Hyg., Vol. 39, No. 4, str. 427-439, 1995) | ||
| 82 | Sludge, sediments | Sampling of sludge and sediments Regulated area: Sampling |
VZ 10 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15) | ||
Reference standards (190)
AHEM č. 1/2008
DIN 38414-17
M. Hery, Ann.Occup.Hyg., Vol. 39, No. 4, str. 427-439, 1995
M. Sedláček a kol., Metody rozboru kalů a pevných odpadů, SZN 1978
Metodický pokyn MŽP ke vzorkování odpadů – duben 2008
Návod firmy DIRAM
ONORM S 2027-4
TNV 75 7552
VZ 01
VZ 02
VZ 03
VZ 04
VZ 05
VZ 07
VZ 08
VZ 10
ZP 002
ZP 003
ZP 004
ZP 005
ZP 006
ZP 007
ZP 008
ZP 009
ZP 010
ZP 011
ZP 012
ZP 013
ZP 015
ZP 016
ZP 017
ZP 018
ZP 020
ZP 021
ZP 022
ZP 023
ZP 024
ZP 025
ZP 026
ZP 027
ZP 028
ZP 030
ZP 031
ZP 034
ZP 036
ZP 037
ZP 043
ZP 044
ZP 045
ZP 046
ZP 047
ZP 048
ZP 050
ZP 051
ZP 052
ZP 053
ZP 055
ZP 056
ZP 060
ZP 061
ZP 062
ZP 063
ZP 071a
ZP 071b
ZP 072
ZP 073a
ZP 073b
ZP 074a
ZP 074b
ZP 075a
ZP 075b
ZP 077
ZP 078
ZP 085
ZP 090a
ZP 090b
ZP 093a
ZP 093b
ZP 094
ZP 095
ZP 100
ZP 101
ZP 102a
ZP 102b
ZP 102c
ZP 102d
ZP 102e
ZP 104
ZP 105
ZP 106
doporučení SÚJB
návod firmy Diram
návod firmy Empos
návod firmy Hach
návod firmy Labtech
ČSN 46 5735
ČSN 75 7300
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7360
ČSN 75 7372
ČSN 75 7415
ČSN 75 7440
ČSN 75 7508
ČSN 75 7536
ČSN 75 7600
ČSN 75 7611
ČSN 75 7612
ČSN 75 7624
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN EN 13342
ČSN EN 13656
ČSN EN 13657
ČSN EN 13805
ČSN EN 13806
ČSN EN 14039
ČSN EN 14702-1
ČSN EN 1484
ČSN EN 14899
ČSN EN 14902
ČSN EN 15216
ČSN EN 15934
ČSN EN 15935
ČSN EN 16166
ČSN EN 16171
ČSN EN 17322
ČSN EN 17503
ČSN EN 1899-2
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 11731
ČSN EN ISO 14189
ČSN EN ISO 14911
ČSN EN ISO 15061
ČSN EN ISO 15587-2
ČSN EN ISO 16266
ČSN EN ISO 16703
ČSN EN ISO 17294-2
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 22155
ČSN EN ISO 4833-1
ČSN EN ISO 4833-2
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6579-1
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 16649-2
ČSN ISO 17289
ČSN ISO 17858
ČSN ISO 21527-1
ČSN ISO 21527-2
ČSN ISO 4832
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-12
ČSN ISO 5667-18
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6439
ČSN ISO 7150-1